Honeywell Analytics Asia Pacific RMBLEM5 Bluetooth Low Energy Module-RMBLE-M5 User Manual OELD Instruction Manual
Honeywell Analytics Asia Pacific Co., Ltd. Bluetooth Low Energy Module-RMBLE-M5 OELD Instruction Manual
Contents
Module manual
User Manual RMBLE-M5 RMBLE-M5 Manual Revision 0 Content 1 Overview .................................................................................................................................................. 2 2 Pin Definition ........................................................................................................................................... 3 3 Specification ............................................................................................................................................ 4 3.1. Voltage........................................................................................................................................ 4 3.2. Digital Levels .............................................................................................................................. 4 3.3. Current Consumption ................................................................................................................. 4 3.4. RF Specification ......................................................................................................................... 4 3.5. PCB layout footprint .................................................................................................................... 5 3.6. Physical/Environmental Specification ......................................................................................... 6 4 Wireless Certification Information ............................................................................................................ 7 RMBLE-M5 Manual Revision 0 1 Overview RMBLE-M5 is a highly-integrated Bluetooth low-energy (BLE) module, which offers a complete solution containing all hardware features necessary for development of wireless application. Key Features: Ultra compact size (18.8 X 13.5 mm) Embedded 512 Kb EEPROM I2C, SPI, and UART interfaces Low power consumption Embedded antenna design RoHS compliant, certified lead-and halogen-free BT4.1 Compliant RMBLE-M5 uses a radio technology called frequency-hopping spread spectrum (FHSS). The transmitted data are divided into packets and each packet is transmitted on one of the 40 channels, channel spacing 2 MHz. The first channel starts at 2402 MHz and continues up to 2480 MHz. RMBLE-M5 can coexist with DSSS based Wi-Fi very well due to different transmit protocol. RMBLE-M5 offers superios radio performance, based on Broadcom BCM20737S. RMBLE-M5 Manual Revision 0 2 Pin Definition Connector Pin 4-7 10 11 12 13 14 15, 16 17 18, 19 20 Pin Name SPI_CLK SPI_MISO SPI_MOSI NA RESET GND NA I2C_CLK I2C_DATA BL_UART_RX BL_UART_TX NA GPIO NA GPIO/LED 21 22 23 24 25 26-30 31, 32 33 34 35 36 37 38 39 40 41-42 43 SPI_CS GND GND VCC VCC NA ADC NA VCC GND GPIO NA PRGM_UART_RX PRGM_UART_TX NA GPIO WakeUp Description Master SPI clock line, reserved Master SPI master slave out line, reserved Master SPI master out slave in line, reserved No connection Active-low system reset Ground No connection PU clock signal for an external I2C device PU data signal for an external I2C device Peripheral UART RX Peripheral UART TX No connection General Purpose Digital Input/Output No connection Status indicate: output continuous 0/1 signal when not sleep. Output 0 when in sleep Master SPI chip select line, reserved Ground Ground Digital supply voltage Digital supply voltage No connection ADC Input, reserved No connection Digital supply voltage or no connection Ground General Purpose Digital Input/Output No Connection HCI, PRGM_UART RX HCI, PRGM_UART TX No connection General Purpose Digital Input/Output WakeUp the Module, Active low I/O I/O I/O I/O RMBLE-M5 Manual Revision 0 3 Specification 3.1. Voltage Power supply for the RMBLE-M5 module is provided by the host power pins: Symbol Min Typ Max VCC 1.62 3.3 3.63 Unit 3.2. Digital Levels Power supply for the RMBLE-M5 module is provided by the host power pins: Symbol Min Typ Max VIH 0.75 VCC VIL 0.4 VOH VCC-0.4 VCC VOL 0.4 Unit 3.3. Current Consumption Condition: 25 °C, the default voltage is 3.3 V Item Condition Receive Receiver and baseband are both operating, 100 % Transmit Transmitter and baseband are both operating, 100 %, Tx power setting: 3 dBm Normal Normal current (Average) Sleep Min Nom 25 Max Unit mA 26 mA 300 mA uA 3.4. RF Specification The RF performance of RMBLE-M5 is given as follows. The default voltage is 3.3 V Item Condition Min Nom Max Frequency 2402 2480 Channel space Rx sensitivity Packet: 200, Payload, PRBS9 -94(1) Length: 37 Bytes, Dirty Transmitter: off PER 30.8 % Max input -10 Tx Power -20 (BCM20737S) Tx Power -14 (RMBLE-M5) Distance Communicate with Iphone5, 20 LOS, 1.5 m height Note (1): Rx sensitivity and Tx power is specification of BCM20737S chip Unit MHz MHz dBm dBm dBm dBm RMBLE-M5 Manual Revision 0 3.5. PCB layout footprint The below diagram shows the PCB layout recommended for RMBLE-M5 module: Please don’t place GND plane in the keep-out area, and minimize the area metal traces occupied in the area. It is recommended to have a 0.4 mm gap (T) between the module’s upper surface and the plastic housing. RMBLE-M5 Manual Revision 0 3.6. Physical/Environmental Specification Parameters Size Operating Temperature Operating Humidity Value 18.8 X 13.6 X 2.0 mm -40 ~ +60 °C No more than 80% Comments RMBLE-M5 Manual Revision 0 4 Wireless Certification Information CE0984 FCC ID: 2AISERMBLEM5 IC ID: 21613-RMBLEM5 Model: RMBLE-M5 Manufacturer: Honeywell Analytics Asia Pacific, Co., Ltd. 7F SangAm IT Tower, 434 Worldcup Buk-ro, Seoul 03922, Korea Frequency range: 2402 – 2480 MHz Maximum Tx Power: -14 dBm Note: The host units Tx power can be lower or host units maximum Tx power can be varied per host units PCB, enclosure and etc. It is host manufacturer’s responsibility to ensure Tx power is close to the maximum This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. RF exposure information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines. This equipment has very low levels of RF energy that it deemed to comply without maximum permissive exposure evaluation (MPE). But it is desirable that it should be installed and operated keeping the radiator at least 20cm or more away from person’s body. RMBLE-M5 Manual Revision 0 5 Regulatory Statements - OEM integrators must ensure that its product is electrically identical to RMBLE-M5’s reference designs. Any modifications to RMBLE-M5’s reference designs may invalidate regulatory approvals in relation to the product, or may necessitate notifications to the relevant regulatory authorities. - OEM integrators are responsible for regression testing to accommodate changes to designs, new antennas, and host and submit for C2PC filings. Colocation with other transmitter modules will be addressed through filings for those co-located transmitters when necessary or that colocation of other transmitters will be according to applicable KDB guidelines including those for RF exposure -The final system integrator must ensure there is no instruction provided in the user manual or customer documentation indicating how to install or remove the transmitter - Appropriate labels must be affixed to the product that complies with applicable regulations in all respects. The regulatory label on the final system must include the statement: “Contains FCC ID: 2AISERMBLEM5 and/or IC: 21613-RMBLEM5”. - A user’s manual or instruction manual must be included with the product that contains the text as required by applicable law shall be provided to OEM integrators. - RF Exposure or EMC test might need to be evaluated against the host again. 5.1 USA—Federal Communications Commission (FCC) FCC COMPLIANCE STATEMENT: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. INFORMATION TO USER: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna -Increase the distance between the equipment and the receiver. -Connect the equipment to outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. RMBLE-M5 Manual Revision 0 Caution: Exposure to Radio Frequency Radiation. To comply with FCC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. This device must not be collocated or operating in conjunction with any other antenna or transmitter. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. The final host manual shall include the following regulatory statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna -Increase the distance between the equipment and the receiver. -Connect the equipment to outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To comply with FCC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. This device must not be collocated or operating in conjunction with any other antenna or transmitter. 5.2. Canada - Industry Canada (IC) This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. RMBLE-M5 Manual Revision 0 Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). L‘utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. Caution: Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. En vertu de la réglementation de l'industrie du Canada, cet émetteur de radio ne peuvent fonctionner en utilisant une antenne d'un type et maximum (ou moins) Gain approuvé pour l'émetteur par Industrie Canada. pour réduire risque d'interférence aux autres utilisateurs, le type d'antenne et son gain doivent être choisis de sorte que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour la réussite de communication. RMBLE-M5 Manual Revision 0 Find out more at www.honeywellanalytics.com Contact Honeywell Analytics: Europe, Middle East, Africa, India Life Safety Distribution AG Javastrasse 2 8604 Hegnau Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com Customer Service Tel: +800 333 222 44 (Freephone number) Tel: +41 44 943 4380 (Alternative number) Fax: +800 333 222 55 Middle East Tel: +971 4 450 5800 (Fixed Gas Detection) Middle East Tel: +971 4 450 5852 (Portable Gas Detection) India Tel: +91 124 4752700 Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8210 detectgas@honeywell.com www.honeywell.com Asia Pacific Honeywell Analytics Asia Pacific #701 Kolon Science Valley (1) 43 Digital–Ro 34–Gil, Guro–Gu Seoul 152–729 Korea Tel: +82 (0)2 6909 0300 Fax: +82 (0)2 2025 0328 analytics.ap@honeywell.com Technical Services EMEAI: HAexpert@honeywell.comUS US: ha.us.service@honeywell.com AP: ha.ap.service@honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This publication is not intended to form the basis of a contract
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Kim, Jesse Create Date : 2016:11:04 15:39:59+09:00 Modify Date : 2016:11:04 15:40:05+09:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2016:11:04 15:40:05+09:00 Creator Tool : Acrobat PDFMaker 10.1 for Word Document ID : uuid:fa1c7b6c-a382-41e5-8b51-070c30079cd3 Instance ID : uuid:8c1c11c2-e0e9-4a02-b42b-d52e736cb24b Subject : 3 Format : application/pdf Title : OELD Instruction Manual Creator : Kim, Jesse Producer : Adobe PDF Library 10.0 Source Modified : D:20161104063616 Company : CodeWrights Page Layout : OneColumn Page Count : 12EXIF Metadata provided by EXIF.tools