Honeywell orporated DR4220 Proximity Reader User Manual 7600033D 4220 4 5 02
Honeywell International Incorporated Proximity Reader 7600033D 4220 4 5 02
Contents
- 1. Manual
- 2. Users Manual
Users Manual
DigiReader ® DR4220 Installation Notes IC: 573G-DR4220 FCC ID: C4PDR4220 (The term "IC:" before the radio certification number only signifies that Industry Canada technical specifications were met.) Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. August 2, 2006 © 2006 Honeywell International. All rights reserved. Document 7600033 Revision F Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. DigiReader DR4220 Installation Notes DIGIREADER DR4220 INSTALLATION NOTES ON DIP ADDRESS SWITCH The DR4220 reader has a 5-position DIP-switch S1, (as shown to the right, with S-NET address 1 selected). Switch S1 Settings S-NET Address or Function Off Off Off Off Off Off-line 0 On Off Off Off Off Off On Off Off Off On On Off Off Off Off Off On Off Off On Off On Off Off Off On On Off Off On On On Off Off Off Off Off On Off On Off Off On Off Off On Off On Off 10 OFF Switch S1 Settings S-NET Address or Function On On Off On Off 11 Off Off On On Off 12 On Off On On Off 13 Off On On On Off 14 On On On On Off 15 Off Off Off Off On 16 Off On Off On On Wiegand I/F (26-bit) On On Off On On Wiegand I/F (34-bit) Off On On On On DEMO Mode On On On On On TEST Mode INTERNAL INTERFACE CABLE An attached pigtail cable assembly provides the connection from the printed circuit assembly to the access control unit wiring on a DigiReader DR4220. The cable is colorcoded as follows: COLOR Red FUNCTION (S-NET Use) +12.5 to +24VDC S-NET Nominal (max. draw 500mA) Green S-NET A For use with NexWatch access control panels White S-NET B Black GND S-NET DC Return Shield Earth S-NET Shield Blue Data 0 (Out 0) Orange Data 1 (Out 1) NA Yellow LED 0 Brown LED 1 (Wiegand Use) Wiegand Nominal NA Wiegand DC Return Wiegand Shield: Tied to Wiegand DC Return For use with Wiegand access control panels (Green) Both LEDs are ACU-controlled and are ON/low or OFF/high (Red) TAMPER The DR4220 sends a tamper signal to an S-NET-based ACU when a tamper occurs. P/N 7-600033 Rev. F ©Honeywell International. All Rights Reserved. DigiReader DR4220 Installation Notes MOUNTING INSTRUCTIONS: Carefully choose the installation site to avoid possible external sources of RF interference. Interference may cause reduced performance, so DO NOT locate the unit near motors, pumps, generators, DC-AC converters, AC switching relays, light dimmers, etc., or within 10 feet (3 m) of a computer terminal. WARNING: DO NOT mount the unit on or near any type of metal, including nonferrous metals such as aluminum. (Metal may cause reduced performance or possible damage to the unit.) The unit may NOT operate properly if it is in near to, or mounted directly on metal, reinforced steel in concrete, screens, or reinforcing bars. In addition, the unit must not be framed with or surrounded by metal of any kind. If the unit must be mounted near metal structures, ensure that it has a minimum of 10 inches (25.4 cm) clearance at the rear and surrounding sides. Never cover the front of the DigiReader with any type of metal. Metal anywhere near the device can reduce the read range. In general, as the amount of metal close to the device increases, the reliable maximum read range decreases. 3/4" Plywood or Lexan Sheet PEDESTAL-MOUNTING INSTRUCTIONS: Goose-Neck Assembly Mounted to Lexan R /Plywood in Middle of Transmit Coil There must be no conducting metal closer than 10 inches to the DR4220 reader, except for a unit mounted with a goose-neck pedestal mounting tube, as shown in figure 1. The recommended mounting methods follow: 1. Remove the case front (cover). 2. Use the NexWatch-supplied drilling template to pre-drill 4 holes on the plywood or LEXAN® sheet (recommended ¾" thick). A channel must be cut into the plywood or LEXAN® for the cable between the exit point of the reader and the goose-neck. 3. Mount the plywood or LEXAN® sheet to a goose-neck pedestal mounting tube. (A minimum of 10" clearance is recommended between the back of the reader and the vertical metal tubing). Center the mounting tube. (See figures 1 and 2.) P/N 7-600033 Rev. F 10” Minimum Clearance Between Back of Reader and Vertical Metal Tubing Figure 1 Figure 2 ©Honeywell International. All Rights Reserved. DigiReader DR4220 Installation Notes 4. See the INTERNAL INTERFACE CABLE section on page 1 to install the colorcoded pigtail cable. 5. Route the cable through a channel on the plywood or LEXAN® sheet. (See page 4: RECOMMENDED STAND-OFF PLATE.) 6. Mount the DR4220 board and case back (back plate) to the plywood or LEXAN® sheet which is securely attached to the goose-neck as shown in figure 3. 7. Set the address switch, as required. 8. Install the case front (cover) and be sure that the LED is not damaged as it enters the lens assembly. 9. Secure the case front four holes with the supplied screws. (See figure 4.) Figure 3 WALL-MOUNTING INSTRUCTIONS: There must be no conducting metal closer than 10 inches to the DR4220 reader. The recommended mounting methods follow: 1. Remove the case front (cover). 2. Use the NexWatch-supplied drilling template (included with reader) to drill four holes in the wall. 3. Follow the INTERNAL INTERFACE CABLE instructions to install the pigtail cable. (See page 1.) 4. Mount the DR4220 board and case back (back plate) using 2¼" Panhead #6-32 thread screws (or other means appropriate to the wall composition). 5. Set the address switch, as required. 6. Install the case front (cover) and be sure that the LED is not damaged as it enters the lens assembly. 7. Secure the case front four holes with the supplied screws. (See figure 4.) P/N 7-600033 Rev. F Figure 4 ©Honeywell International. All Rights Reserved. DigiReader DR4220 Installation Notes RECOMMENDED STAND-OFF PLATE Material is 3/4” LEXAN®, plywood or equivalent. LEXAN® is a Registered Trademark of General Electric Corporation. Honeywell 135 West Forest Hill Avenue Oak Creek, WI 53154 (414) 766-1700 Ph (414) 766-1798 Fax www.honeywell.com Honeywell – Europe Boeblingerstrasse 17 71101 Schonaich Germany Specifications subject to change without notice. © Honeywell International. All rights reserved. Document 7-600033, Revision F
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-702 Modify Date : 2006:08:01 18:20:57-04:00 Create Date : 2006:05:04 12:04:18-04:00 Metadata Date : 2006:08:01 18:20:57-04:00 Creator Tool : FrameMaker 6.0 Format : application/pdf Title : 7600033D-4220-4-5-02.fm Document ID : uuid:d13de8fa-55f1-42d3-9b9a-9bba921b2f9a Instance ID : uuid:851c58e1-a499-4272-9f42-5bdc690c8c76 Producer : Acrobat Distiller 4.05 for Windows Has XFA : No Page Count : 6 Creator : Adobe Illustrator(R) 9.0 For : Quincie C Butts, Honeywell Bounding Box : 72 24 540 720 Container Version : 9 Creator Version : 9 Image Height : 696 Image Width : 468 Image Size : 468x696 Megapixels : 0.326EXIF Metadata provided by EXIF.tools