Ibis Networks 200 RF Module User Manual DataSheetPowerx
Ibis Networks Inc. RF Module DataSheetPowerx
Contents
- 1. User Manual - IS-201
- 2. User Manual - IS-204
User Manual - IS-204
IS-204, IS-205, IS-206 InteliSocket⢠FEATURES ⢠⢠⢠⢠⢠⢠120V/240V 15A/20A ZigBee Pro 128 bit AES Security 20dBm RF Power Surge Protected 0C to 40C DESCRIPTION The IS-204, IS-205, and IS-206 (see part numbering) smart sockets meter plug load energy usage and provides device on/off capability. They work with other InteliSocketsTM to form a secure wireless mesh network for control and reporting of data. Each network has an InteliGatewayTM base station providing connectivity to the Ibis InteliNetworkTM, a cloud-based data collection and analysis application. InteliSockets can be configured to operate on any of the 15 ZigBee channels. In addition, the hive (PANID) has over 4000 possible settings, preventing nearby systems from interfering with each other. PERFORMANCE Parameter Input Voltage (RMS) Input Frequency Output Current (RMS) Output Power Power Consumption Reporting Interval Accuracy (Energy) Accuracy (Voltage) Accuracy (Interval) Resolution RF Range RF Transmit Power Sockets per Network ZigBee Channels ZigBee Hive Size Cord Length Ibis Networks 05/28/15 Symbol VIN Min 108 47 Typ 120/240 50/60 15 IOUT POUT Max 250 63 20 4800 255 0.5 50 20 120 25 0x3FFF 11 0x3000 5.8 x 3.4 x 2.3 20 ¡ 828 Fort Street Mall Suite 600 ¡ Honolulu, HI 96813 ¡ www.ibisnetworks.com Units Hz ms W-s dBm inches inches IS-204, IS-205, IS-206 InteliSocket⢠PART NUMBERING Type IS-204 IS-205 IS-206 Voltage 120 240 240 Current 20 15 20 Connector 5-20P 6-15P 6-20P COMPLIANCE Agency UL916 â Energy Management Equipment ZigBee Profile (Ibis Automation) FCC File E470522 0x114B 2AECN200 ENVIRONMENTAL Parameter Operating Temperature Storage Temperature Relative Humidity Symbol TO TS RH Min -40 Typ 25 Max 40 100 95 Units InteliSockets are for indoor use only. PROTOCOL InteliSockets use the Ibis custom ZigBee profile for commands, acknowledgements, and reporting of data. Refer to the V2 Protocol documentation for details. DATA InteliSockets report data typically every 15 seconds. Each report packet is comprised of socket type, ZigBee channel, ZigBee hive (PANID), interval (seconds), voltage (RMS), frequency (Hz), energy (watt-seconds), and power factor (fraction). From these data we can calculate instantaneous power (watts) and current (amps). Ibis Networks 05/28/15 ¡ 828 Fort Street Mall Suite 600 ¡ Honolulu, HI 96813 ¡ www.ibisnetworks.com IS-204, IS-205, IS-206 InteliSocket⢠¡ The InteliGateway appends additional information (IP, timestamp, location, etc.) before uploading to the InteliNetwork. This allows any socket in the world to be located and addressed individually. PUSHBUTTON The small pushbutton on the side provides addition control features. First and foremost, it is a manual override for turning the outlet on and off (toggle). If pressed for at least two seconds, it causes a reboot of the socket. Finally, if the pushbutton is pressed while plugging in the socket, a factory reset is performed causing the socket to revert back to factory default settings. This is a useful feature for maintenance purposes. LED The LED on the front indicates the state of the socket. When red the outlet is off; green is outlet is on. If LED is blinking, the socket has not yet associated with a mesh network. During a reboot, the LED will flash yellow for a second. WIRING The basic design of the IS-204 InteliSocket allows for it to be wired for either 120V or 208V/240V operation. Load current is defined by the outlet connector used, and can be up to a maximum of 25 amps. FCC This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ⢠Reorient or relocate the receiving antenna. Ibis Networks 05/28/15 ¡ 828 Fort Street Mall Suite 600 ¡ Honolulu, HI 96813 ¡ www.ibisnetworks.com IS-204, IS-205, IS-206 InteliSocket⢠⢠⢠⢠Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the userâs authority to operate this equipment. To satisfy RF exposure requirements, this device and its antenna must operate with a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Ibis Networks 05/28/15 ¡ 828 Fort Street Mall Suite 600 ¡ Honolulu, HI 96813 ¡ www.ibisnetworks.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Author : ibisadmin Create Date : 2015:06:02 08:22:37Z Modify Date : 2015:06:02 14:28:21-07:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : ibisadmin Title : Microsoft Word - DataSheetPower.docx Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:06:02 14:28:21-07:00 Producer : GPL Ghostscript 8.15 Document ID : uuid:233943cf-4379-489e-8c16-8267af92931b Instance ID : uuid:e7a30782-e144-4d44-9850-f3fe116175db Page Count : 4EXIF Metadata provided by EXIF.tools