Itron 100WD AMR transceiver decive for utility meters User Manual Users Guide 3
Itron Inc AMR transceiver decive for utility meters Users Guide 3
Itron >
Contents
Users Guide 3
Installing the 100W/100W+ and 100WP/100WP+ ERT Module To install the Leak Sensor on a pipe (up to 2 1/2-inch OD) 1. Select a Leak Sensor mounting location within 5 feet of the ERT module. Note Leak Sensor mounting orientation is not critical. Orient the sensor to best accommodate your installation. The most important installation practice is to fasten the sensor securely to the pipe. Caution Mount the Leak Sensor on the water input side of the meter. Failure to follow this mounting requirement could result in errors in the leak detection data. Installation requires Itron mounting hardware. Repair costs and service charges relating to the use on non-compliant mounting hardware will be charged to the customer. Contract Itron Support for more information. 2. Insert the mounting plate screws into the holes on the Leak Sensor's curved surface. 3. Secure the mounting plate to the Leak Sensor. 4. Verify the pipe’s mounting surface is free from dirt and debris. Place the curved surface of the LS against the pipe. Caution Do not mount the Leak Sensor on a pipe coupler, joint, or nut. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 30 Installing the 100W/100W+ and 100WP/100WP+ ERT Module 5. Insert the U-bolt around the pipe and into the holes in the plate/Leak Sensor assembly. Secure the U-bolt with the wing nuts. Tighten the wing nuts until snug (to a minimum of 5-inch pounds) to prevent device rotation on the pipe. After the second wing nut is tightened, check the Leak Sensor to verify the device is snug. If the sensor moves, tighten the wing nuts until there is no movement. Caution Do not tighten the Leak Sensor to more than 20 inch-pounds. Over-tightening could damage the Leak Sensor housing and/or the pipe. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 31 CH AP T ER Optional Direct Connect Remote Antenna Installation The optional 900 MHz remote mount antenna provides increased RF range coverage for the listed mobile applications where the meters are located deep in a pit boxes. This section provides antenna mounting instructions through a pit lid and the instructions to connect the optional antenna to the ERT module. Caution Only remote antenna ERT modules can be used with the remote antenna. See the following table for 100W and 100WP remote antenna ERT models. 100W and 100WP ERT Module Models for use with Remote Antennas 100W and 100WP ERT Module Description Itron Part Number 100W + encoder ERT module with optional remote antenna and register integral connectors ERW-1300-202 100W+ encoder ERT module with optional remote antenna and register integral connectors, ISM ERW-1300-302 100W encoder ERT module with optional remote antenna, Leak Sensor, and register integral connectors ERW-1300-203 100W+ encoder ERT module with optional remote antenna, Leak Sensor, and register integral connectors, ISM ERW-1300-303 100W 5-ft. flying leads encoder ERT module with optional remote antenna integral connector ERW-1300-205 100W+ 5-ft. flying leads encoder ERT module with optional remote antenna integral connector, ISM ERW-1300-305 100W 5-ft. flying leads encoder ERT module with optional remote antenna and Leak Sensor connectors ERW-1300-206 100W+ 5-ft. flying leads encoder ERT module with optional remote antenna and Leak Sensor connectors, ISM ERW-1300-306 100W 20 in. flying leads encoder ERT module with optional remote antenna integral connector ERW-1300-217 100W+ 20 in. flying leads encoder ERT module with optional remote antenna integral connector, ISM ERW-1300-317 100WP 20 in. flying leads encoder ERT module with optional remote antenna and Leak Sensor integral connectors ERW-1300-218 100WP+ 20 in. flying leads encoder ERT module with optional remote antenna and Leak Sensor integral connectors, ISM ERW-1300-318 100WP pulser ERT module with optional remote antenna and register integral connectors ERW-1300-208 100WP+ pulser ERT module with optional remote antenna and register integral connectors, ISM ERW-1300-308 100WP pulser ERT module with optional remote antenna, Leak Sensor, and register integral connectors ERW-1300-209 100WP+ pulser ERT module with optional remote antenna, Leak Sensor, and register integral connectors, ISM ERW-1300-309 100WP 5-ft. flying leads pulser ERT module with optional remote antenna and Leak Sensor integral connectors ERW-1300-212 100WP+ 5-ft. flying leads pulser ERT module with optional remote antenna and Leak Sensor integral connectors, ISM ERW-1300-312 100WP 20 in. flying leads pulser ERT module with optional remote antenna integral connector ERW-1300-219 100WP +20 in. flying leads pulser ERT module with optional remote antenna integral connector, ISM ERW-1300-319 100WP 20 in. flying leads pulser ERT module with optional remote antenna and Leak Sensor integral connectors ERW-1300-220 100WP + 20 in. flying leads pulser ERT module with optional remote antenna and Leak Sensor integral connectors, ISM ERW-1300-320 TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 32 Optional Direct Connect Remote Antenna Installation Industry Canada Conformity This radio transmitter (IC:864D-100WC) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le présent émetteur radio (IC: 864D-100WC) aété approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. Specification Part number CFG-0900-003 Gain 2 dBi Horizontal beamwidth Omni-directional Impedance 50 ohms Termination Proprietary Installing the Remote Antenna Metal lids on water pit boxes require a through-lid solution for optimal ERT module radio performance. The remote antenna is designed to fit in a pit lid hole with a diameter of 3/4-inch and lid thicknesses from 1/4-inch to 1-3/4-inch. Caution Remove cable or twist ties from the antenna cable to prevent damage to the ERT module or antenna. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 33 Optional Direct Connect Remote Antenna Installation To install the remote antenna through a pit lid 1. Thread the remote antenna connector and cable through the pit lid hole. Verify the antenna's convex surface is on the top of the pit lid. (These instructions show a simulated pit lid material.) 2. Insert the antenna connector through the rectangular opening in the threaded collar. 3. Turn the threaded collar until it is tight against bottom of the pit lid. To connect the remote antenna to the ERT module 1. Align the connector pins with the top, red connector on the ERT module. The illustration shows a 3-port ERT module connection. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 34 Optional Direct Connect Remote Antenna Installation 2. Push in the antenna connector to complete the connection. The illustration shows a two-port ERT module connection. 3. Turn the connector lock ring to the right to secure the connection. Caution Turn the connector lock-ring only. Do not twist the completed connection. Twisting the connection could damage the ERT module or antenna connector pins. 4. Follow the Rod Mount Installation on page 14 or Wall Mount Installation on page 17 instructions to mount the ERT module. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 35 Optional Direct Connect Remote Antenna Installation Remote antenna installation is complete. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 36
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : TDC-0909-006 Create Date : 2012:11:08 11:32:20-06:00 Modify Date : 2012:11:08 11:33:20-06:00 Subject : Water Solutions Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2012:11:08 11:33:20-06:00 Creator Tool : Acrobat PDFMaker 10.1 for Word Format : application/pdf Title : 100W and 100WP Datalogging Water ERT Module Installation Guide Description : Water Solutions Creator : TDC-0909-006 Document ID : uuid:eeebf69b-070d-46bd-a5a7-2247dbb7baa0 Instance ID : uuid:0a34fd05-46aa-4665-b1ff-c57c3eca8683 Producer : Adobe PDF Library 10.0 Page Count : 7EXIF Metadata provided by EXIF.tools