Itron 100WD AMR tranceiver device for utility meters User Manual 3
Itron Inc AMR tranceiver device for utility meters Users Manual 3
Itron >
Contents
Users Manual 3
Installing the 100W/100W+ and 100WP/100WP+ ERT Module Shelf Mount Installation This section describes 100W/100W+ and 100WP/100WP+ ERT module installation using a shelf mount adapter to mount the ERT module in a pit lid slot. Caution Observe the following guidelines for mounting the ERT module using the shelf mount procedure: • • ERT module positioning other than upright could negatively affect radio performance and battery life. Use only Itron-approved splice kits or inline connectors. The pit lid and slot must have the correct dimensions for the ERT module assembly to fit properly. The following illustration and the accompanying table give pit lid slot dimensions for the shelf mount installation method. Pit Lid Slot Dimensions Dimension Minimum (inches) Maximum (inches) 6 3/4 N/A 5 3/4 3/4 Required Hardware Itron 100W Series Shelf Mount Kit To install using the shelf mount adapter 1. With the foam spacers facing up, insert the shelf mount adapter into the opening in the disk. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 20 Installing the 100W/100W+ and 100WP/100WP+ ERT Module 2. Push the adapter into the opening gently until the adapter snaps into place. Insert the shelf mount adapter into the ERT module antenna slot pushing firmly with your thumb until the adapter tab locks into place in the ERT module antenna slot opening. 3. Slide the adapter assembly into the pit lid with the foam spacers positioned on each side of the pit lid slot. Correct position for foam spacers Caution Do not install the adapter assembly in a manner that provides little or no support under disk's edge. Incorrect mounting position for foam spacers. 4. The installed ERT module position must be vertical and upright when the lid is replaced on the pit. Caution When placing the pit lid on to the pit box after the shelf mount adapter installation, use care to avoid pinching or damaging the ERT module to meter cable. Any ERT module position other than upright may negatively affect radio performance and battery life. Through Lid Installation This section provides instructions to mount the 100W/100W+ and 100WP/100WP+ ERT module in a pit lid with a drilled, round 1-3/4-inch, 1-7/8-inch, or 2-inch hole. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 21 Installing the 100W/100W+ and 100WP/100WP+ ERT Module Through Lid Mount Required Tools and Hardware This mounting method requires the Pit Lid Mounting Kit. Refer to the 100W Installation Methods Overview (PUB-1300-004) for guidance on which kit to install for different pit lid material and traffic conditions. Pit Lid Mounting Kit (CFG-1300-004) Note The Pit Lid Mounting Kit is not intended for applications involving vehicular traffic. Use the Remote Antenna Kit in incidental traffic areas (such as residential environments). This section provides the instructions to install the 100W/100W+ and 100WP/100WP+ ERT module in a pit lid with a hole using the Pit Lid Mounting Kit (CFG-1300-004). Verify you have the following items to complete the installation. Retainer clip Pit lid with a pre-drilled hole (simulated pit lid material shown) Retainer clip collar 100W/100W+and 100WP/100WP+ ERT module TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 22 Installing the 100W/100W+ and 100WP/100WP+ ERT Module To install in lids with holes using the Pit Lid Mounting Kit (CFG-0771-011) 1. Insert the retainer clip into the pit lid hole with the convex surface on the top of the pit lid. 2. From the bottom side of the lid, screw on the threaded retainer clip collar until the beveled top rests against the pit lid. Note Ensure the beveled edge of the clip collar is toward the top of the pit lid. 3. Align and insert the retainer clip tab into the retainer clip receptacle on the ERT module housing. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 23 Installing the 100W/100W+ and 100WP/100WP+ ERT Module 4. Verify the clip locks into place in the housing. Caution Carefully align the ERT module through lid assembly. If the assembly is improperly aligned, the pit lid may not close. Pit lid mounting installation is complete. Optional Leak Sensor Installation This section describes installation of the Leak Sensor (LS) in a 100W/100W+ and 100WP/100WP+ ERT module system. The ERT module stores 20 days of LS data. On the 21st day, the ERT module begins to write over stored data in a first in, first out manner. The ERT module automatically detects the presence of connected LS devices. The ERT module will automatically detect the LS within 22.5 minutes and begin reading LS data. To immediately detect the LS and begin reading data, perform a Check ERT with a handheld computer running FDM software. The LS is used in conjunction with both indoor (basement) and outdoor (mounting on the exterior of the house) 100W/100W+ and 100WP/100WP+ ERT module installations. LS devices are mounted on a water service pipe or meter insetter (meter horn) and connect to the LS connector on the ERT module as described in To connect the Leak Sensor to the 100W/100W+ and 100WP/100WP+ ERT module on page 26. The mounting bracket shipped with the LS accommodates an (up to) 1-1/2-inch OD pipe. An optional mounting bracket is available for pipe sizes (up to 2 1/2-inch OD). TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 24 Installing the 100W/100W+ and 100WP/100WP+ ERT Module Leak Sensor Installation Equipment Equipment Itron Part Number Description Leak Sensor LDS-0001-002 LS with inline connector, environmental connector cap; 5-foot cable, and mounting bolt (fits up to 1 1/2-inchOD pipe). Optional mounting bracket CFG-0349-002 Mounting bolt fits up to 2 1/2-inch OD pipe. ERT module 100W three-port ERT module ERW-1300-203 Triple port encoder ERT module for connectionto register, Leak Sensor, and optional remote antenna. 100W+ three-port ERT module ERW-1300-303 Triple port encoder ERT module for connectionto register, Leak Sensor, and optional remote antenna, ISM 100W, 5-ft. flying leads, two-port ERT module ERW-1300-206 Three-port encoder ERT module for connectionto register using 5-ft. flying leads, Leak Sensor and optional remote antenna connectionwith inline connectors. 100W+, 5-ft. flying leads, two-port ERT module ERW-1300-306 Three-port encoder ERT module for connectionto register using 5-ft. flying leads, Leak Sensor and optional remote antenna connectionwith inline connectors, ISM Three-port encoder ERT module for connectionto register using 20-in. flying leads, Leak Sensor, and optional remote antenna connectionwith inline connectors. Three-port encoder ERT module for connectionto register using 20-in. flying leads, Leak Sensor, and optional remote antenna connectionwith inline connectors, ISM Three-port pulser ERT module for connectionto register, Leak Sensor, and optional remote antenna. Three-port pulser ERT module for connectionto register, Leak Sensor, and optional remote antenna, ISM Three-port pulser ERT module for connectionto register using 5-ft. flying leads, Leak Sensor, and optional remote antenna connectionwith inline connectors. 100W, 20-in. flying leads, three-port ERW-1300-218 encoder ERT module 100W+, 20-in. flying leads, threeport encoder ERT module ERW-1300-318 100WP three-port ERT module ERW-1300-209 100WP +three-port ERT module ERW-1300-309 100WP, 5-ft. flying leads, two-port ERT module ERW-1300-212 100WP+, 5-ft. flying leads, two-port ERT module ERW-1300-312 Three-port pulser ERT module for connectionto register using 5-ft. flying leads, Leak Sensor, and optional remote antenna connectionwith inline connectors, ISM 100WP, 20-in. flying leads, threeport pulser ERT module ERW-1300-220 Three-port pulser ERT module for connectionto register using 20-in. flying leads, Leak Sensor, and optional remote antenna connectionwith inline connectors. 100WP+, 20-in. flying leads, threeport pulser ERT module ERW-1300-320 Three-port pulser ERT module for connectionto register using 20-in. flying leads, Leak Sensor, and optional remote antenna connectionwith inline connectors, ISM 25-foot extensioncable (optional) CFG-0349-101 25-foot cable with coordinating connectors (LS blue connector, register black connector). 100W LS environmental replacement cap MSC-0019-008 Protects Leak Sensor connector when the LS is not connectedto the 100W ERT module. Itron Security Seal MSC-0018-001 Indicates module tampering and ensures the protective cover stays intact. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 25 Installing the 100W/100W+ and 100WP/100WP+ ERT Module Leak Sensor Optional Mounting Bracket 3-port Module Two-port/flying lead module Warning When the 100W/100W+ or 100WP/100WP+ is installed but the LS is not attached, you must protect the blue port with the universal environmental cap (MSC-0019-008). If you remove the LS from the ERT module, the environmental cap must be replaced to protect the connector. To connect the Leak Sensor to the 100W/100W+ and 100WP/100WP+ ERT module Caution Verify you have the correct 100W/100W+ or 100WP/100WP+ ERT module. Leak Sensors must mount to Port B (middle blue port) of the ERT module. Connecting the LS to Port A (bottom port) or Port C (top port) will cause electrical damage to the LS and ERT module. 1. Remove the environmental cap from the ERT module's blue connector (B). C. Red connector: Optional antenna connection B. Blue connector: Leak Sensor connection A. Black connector: register connection 2. Remove the environmental cap from the Leak Sensor connector. Verify the connectors (the ERT module's LS connector and the Leak Sensor connector) are clean and dry. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 26 Installing the 100W/100W+ and 100WP/100WP+ ERT Module 3. Align the Leak Sensor connector with the ERT module's blue connector and insert. 4. Rotate the connector locking ring until the security holes align. Caution Do not force the connector ends together. While you hold the LS connector, engage the ERT module's connector by rotating the locking ring until both connectors securely connect. Twist only the connector locking ring, not the body of the connector. Twisting the connector body could damage the connector's pins. To attach an Itron Security Seal through the connector security hole 1. Insert the pointed end of the security seal through the inline connector and the ERT module connector security holes. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 27 Installing the 100W/100W+ and 100WP/100WP+ ERT Module 2. Insert the pointed end of the security seal into the capped end and push until the seal locks. This completes the ERT module and Leak Sensor connections. Pipe Preparation Clean any dust or dirt from the pipe to facilitate direct contact with the LS surface. To install the Leak Sensor on a pipe or meter insetter 1. Select a Leak Sensor mounting location within 5-feet of the ERT module. Mount the sensor on the water input side of the meter. Caution Mount the Leak Sensor on the water input side of the meter. Failure to follow this mounting requirement could result in errors in the leak detection data. Installation requires Itron mounting hardware. Repair costs and service charges relating to the use on non-compliant mounting hardware will be charged to the customer. Contract Itron Support for more information. 2. Verify the pipe’s mounting surface is free from dirt and debris. Place the curved surface of the LS against the pipe. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 28 Installing the 100W/100W+ and 100WP/100WP+ ERT Module 3. Insert the mounting U-bolt over the pipe and into the LS mounting holes. Caution Do not mount the Leak Sensor on a pipe coupler, joint, or nut. 4. Insert the mounting plate over the U-bolt's threaded screw ends. Attach the two wing nuts over the clamp screw ends and tighten the wing nuts until snug (to a minimum of 5-inch pounds) to prevent device rotation on the pipe. After you tighten the second wing nut, check the Leak Sensor to verify the device is snug. If the sensor moves, tighten the wing nuts until there is no movement. Caution Do not tighten the Leak Sensor to more than 20 inch-pounds. Over-tightening could damage the Leak Sensor housing and/or the pipe. Note Leak Sensor mounting orientation is not critical. Orient the sensor to best accommodate your installation. The most important installation practice is to mount the sensor securely to the pipe. TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide Proprietary and Confidential 29
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : TDC-0909-006 Create Date : 2012:11:08 11:24:39-06:00 Modify Date : 2012:11:08 11:26:37-06:00 Subject : Water Solutions Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2012:11:08 11:26:37-06:00 Creator Tool : Acrobat PDFMaker 10.1 for Word Format : application/pdf Title : 100W and 100WP Datalogging Water ERT Module Installation Guide Description : Water Solutions Creator : TDC-0909-006 Document ID : uuid:4a5547d3-4394-41b5-b18a-478ca20a61bb Instance ID : uuid:08715908-6fff-4cd3-bd01-a46e372f4252 Producer : Adobe PDF Library 10.0 Page Count : 10EXIF Metadata provided by EXIF.tools