Kamstrup A S FLOW2102 Water Flow Meter User Manual UserMan a

Kamstrup A/S Water Flow Meter UserMan a

Contents

UserMan a

Download: Kamstrup A S FLOW2102 Water Flow Meter User Manual UserMan a
Mirror Download [FCC.gov]Kamstrup A S FLOW2102 Water Flow Meter User Manual UserMan a
Document ID2655006
Application ID6OyjGuxCRaSx9P9XHQFpiQ==
Document DescriptionUserMan a
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize118.83kB (1485377 bits)
Date Submitted2015-06-23 00:00:00
Date Available2015-06-23 00:00:00
Creation Date2015-06-02 12:16:47
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2015-06-02 12:17:56
Document TitleUserMan a
Document CreatorAdobe InDesign CC 2014 (Windows)

Optical eye for reading and configuration
Optional customer label, e.g. water company logo (15x38 mm)
Bar code with serial number
Graphic flow indicator
Expiry year of battery
Type number
(includes information on meter
Temperature class according to OIML R 49
flowIQ® 2102
Serial no. and prod. year
Meter size Q3
Software version and dynamic range
FCC ID: OUY-FLOW2102
Configuration
(with information on display resolution
Pressure stage and protection class
FCC identification
Accuracy class 2 according to OIML R49
Environment class: Electrical E2 and Mechanical M1
Environment class B and C according to OIML R49
The coupling’s sealing
surface must be clean
and even.
FCC Cautions
Caution: Changes or modifications not expressly approved
by the party responsible for compliance could void the user’s
authority to operate the equipment.
RF Exposure compliance statement: This device may be used
with no restrictions, since the source-based time-averaged
output power is ≤ 60/f(GHz) mW.
If you have a smart phone you can enter this QR code to enter
www.kamstrup.com
ALWAYS use new gaskets (PE
or EPDM).
Torque
If a pipe installation is skew to the effect that the prescribed
tightening torques would be exceeded, a telescopic coup-ling
ought to be installed.
¾”
1”
Max. 15 Nm
Max. 30 Nm
flowIQ® 2102
Installation guide
¾”: Max. 15 Nm
1”: Max. 30 Nm
DRAFT-5512XXXX_A1_CL-GB_06.2015
The piping must be parallel and match the meter.
1. General information
Read this guide before installing the water meter.
flowIQ® 2102 is a compact electronic water meter used for water
consumption measurement in the tap water supplies of homes,
commercial and industrial buildings. The meter is available in
two versions for cold and hot water respectively.
flowIQ® 2102 is intended for maintenance-free operation for up
to 16 years depending on the installed battery type.
flowIQ® 2102 is hermetically closed, and it is, therefore,
impossible to service the meter without breaking the seal. This
means that all service including battery change must be carried
out by an authorized Kamstrup Service Centre.
Certain changes of configuration, however, are possible via
the built-in optical eye without dismounting the meter from
the installation. Further details appear from data sheet and
technical description.
For sealing you can use the sealing wire holes on the lower side
of the threaded connections.
Mounting the meter you must make sure that the threaded
length of the couplings does not prevent proper tightening of
the sealing surface, and that PN10 or PN16 couplings are used.
flowIQ® 2102 has a large-meshed strainer (filter) pre-mounted
in the meter inlet socket.
For both meter sizes 2.5 m3/h and 4.0 m3/h, a nonreturn valve,
to be mounted concealed in the meter outlet socket, is available.
Thin 2 or 3 mm gaskets must be used for mounting. Non-return
valve must be pressed into the outlet of the meter; the black
o-ring pointing inwards in the meter. Press firmly the valve, into
the meter outlet socket, until it reaches limit stop.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Medium temperature
cold water meter:
Medium temperature
hot water meter:
Pressure stage:
Mechanical environment:
Electromagnetic
environmental class:
0.1°C...50°C
0.1°C...70°C
PN16
M1 Fixed installation with minimum
vibration.
E1 and E2. Residential and
commercial
IP68
2°C...55°C. Condensing humidity.
(indoors mounted in utility rooms
and outdoors in meter wells).
Installation in direct sunlight must
be avoided.
Protection class:
Climatic environment:
Non-return valve
Gasket
Service
When the meter has been mounted in the system, neither
welding nor freezing is allowed. Dismount the meter from the
system before starting such work.
In order to facilitate replacement of the meter, closing valves
should be mounted on both sides of the meter.
Under normal operating conditions no pipe strainer is required
in front of the meter. Non-return valves must be mounted
according to national local regulations.
1.3 Installation angle of flowIQ® 2102
flowIQ® 2102 can be mounted at all angles and positions.
Kamstrup A/S recommend that the display is mounted so that it
is easy to read, if possible.
Thus, the meter can be mounted in a usual horizontal
installation. It can be mounted vertically in an ascending pipe,
it can be mounted at any angle and it can be mounted with its
display facing down, e.g under a roof.
Mounting the meter in a downpipe, you must be aware that the
display in that case will be ’upside-down’.
1.2 Installation requirements
1.4 Straight inlet
Prior to installation of flowIQ® 2102 the system should be
flushed while a fitting piece replaces the meter. Mount the meter
with couplings. You must always use new gaskets in original
quality.
Following gaskets can be used:
flowIQ® 2102 requires neither straight inlet nor straight outlet to
meet the Measuring Instruments Directive (MID) 2004/22/ EC
and OIML R49. A straight inlet section will only be necessary in
case of heavy flow disturbances before the meter.
¾”
Cold water
2 mm EPDM or PE
Hot water
2 mm PTFE with silicate fill
1”
3 mm EPDM or PE
3 mm PTFE with silicate fill
The flow direction is indicated by an arrow on the side of the
meter housing.
During installation it must be secured that the meter is mounted
without mechanical bias in the connection pipes. The couplings
must be tightened with maximum the following torque:
Recommended water meter position.
Recommended water meter position.
Used for ”pit installation”. Air build-up may occur.
The meter functions optimally, but the display is ’upsidedown’.
¾”
15 Nm
1.5 Operating pressure
1”
30 Nm
In order to avoid cavitation and secure correct measurement,
under all circumstances, the operating pressure in the pipe
installation must observe the test conditions of OIML R 49, which
means that the static pressure immediately after the meter
(downstream) must always be minimum 0.03 MPa (0.3 bar).
If a tight connection cannot be obtained within these limits, the
pipe installation must be corrected in order to remove strains.
Alternatively, a telescopic coupling must be installed.
Such couplings can be supplied by Kamstrup A/S.
When flowIQ® 2102 leaves Kamstrup A/S, it has been tested and
verified and the counter has been reset.
The number of m3 is displayed by five large digits. The small
digits are decimals after the point.
A number of info codes can be displayed, of which DRY
and RADIO OFF will be activated and flash upon delivery.
Furthermore, the two small squares in the bottom right-hand
corner flash to indicate that the meter is active.
Info code DRY indicates there is air in the meter; the info code
disappears when the meter is water-filled.
The info code RADIO OFF indicates that the meter is still in
transport mode with the built-in radio transmitter turned off. The
transmitter turns on automatically when the first litre of water
has run through the meter. The radio transmitter remains on,
and the info code signal in the display switches off.
The flow arrows in the left side of the display indicate water flow
through the meter. If the water is stagnant, all arrows will be off.
The table below describes the different info codes in the display.
Flow
Gasket
1.1 Permissible operating conditions / measuring
ranges
1.6 Info codes and display
The figure after the ’A’ states how many times the meter
has been adjusted. In a completely new meter both of these
characters will be out.
Laboratories which have reverified and adjusted or reset the
meter must supply the meter with a label with information on
the current adjustment figure.
Info code flashes in the Meaning
display
LEAK
The Water has not been stagnant
in the meter for minimum one
continuous hour during the latest 24
hours.
This can be a sign of a leaky faucet or
toilet cistern.
BURST
The water flow has exceeded a
preprogrammed limit for minimum
30 minutes which is a sign of a burst
pipe.
TAMPER
Attempt of fraud. The meter is no
longer valid for billing purposes.
DRY
The meter is not water-filled.
REVERSE
The water flows through the meter in
the wrong direction.
RADIO OFF
The meter is still in transport mode
with the built-in radio transmitter
turned off. The transmitter turns on
automatically when the first litre of
water has run through the meter.
■■(two square ’dots’) Two small squares alternately flashes,
indicating that the meter is active

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c014 79.156797, 2014/08/20-09:53:02
Create Date                     : 2015:06:02 12:16:47+02:00
Metadata Date                   : 2015:06:02 12:17:56+02:00
Modify Date                     : 2015:06:02 12:17:56+02:00
Creator Tool                    : Adobe InDesign CC 2014 (Windows)
Instance ID                     : uuid:15cfc530-c27e-4c03-8031-24831ea0de68
Original Document ID            : xmp.did:CE01E6A1DFEFE0118D6AC478EE4E4D07
Document ID                     : xmp.id:a4532662-d94f-504a-a7ca-1b5f54527071
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:043a390d-39ea-c948-9c5d-64fff48d5b10
Derived From Document ID        : xmp.did:65dd117f-c87a-6f42-b39c-3b6d75fa9f42
Derived From Original Document ID: xmp.did:CE01E6A1DFEFE0118D6AC478EE4E4D07
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Windows)
History Changed                 : /
History When                    : 2015:06:02 12:16:47+02:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CC 2014 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OUY-FLOW2102

Navigation menu