LG CNS KSCCCBR400A AUTOMATIC RECHARGER User Manual Manual

LG CNS CO., LTD. AUTOMATIC RECHARGER Manual

Users Manual

Download: LG CNS KSCCCBR400A AUTOMATIC RECHARGER User Manual Manual
Mirror Download [FCC.gov]LG CNS KSCCCBR400A AUTOMATIC RECHARGER User Manual Manual
Document ID1705167
Application IDWVgpfM2HlPk5NNKl38mAfw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize310.57kB (3882119 bits)
Date Submitted2012-05-23 00:00:00
Date Available2012-05-23 00:00:00
Creation Date2012-05-23 12:02:48
Producing SoftwareAcrobat Distiller 9.4.2 (Windows)
Document Lastmod2012-05-23 12:02:48
Document TitleMicrosoft Word - Manual.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: JJ

Sistema de Recaudo Control e Información y
Servicio al Usuario Proyect
Maintenance and Repair Manual
(Heavy)
Automatic Recharger
CB-EDR-HM-00-V1.0
Copyright ⓒ LG CNS
It is forbidden to copy and distribute on certain or whole part of this content without precedent approval of LG CNS
Bogota SIRCI Project
Document
Maintenance and
Repair Manual (Heavy)
CB-EDR-HM-00-V1.0
User Requirement Definition
Prepared by:
Automatic
Recharger
Reviewed by:
Approved by:
Page i of All
Bogota SIRCI Project
User Requirement Definition
Document History
Previous
Version
Present
Document
CB-EDR-HM-00-V1.0
Date
Numeral
Automatic
Recharger
Changes
Type
Page ii of All
Bogota SIRCI Project
User Requirement Definition
Table Of Contents
1. AUTOMATIC RECHARGER EQUIPMENT STRUCTURE .......................................1
1.1 Overview ...............................................................................................................1
1.2 External / Internal Structure and Main Module ..................................................1
1.2.1 External Structure .............................................................................................1
1.2.2 Main Module Structure I ....................................................................................2
1.2.3 Internal Structure ..............................................................................................3
1.2.4 Main Module Structure II ...................................................................................4
2. ERROR HANDLING .................................................................................................6
2.1.1 Supply of the power (1/3) ..................................................................................6
2.1.2 Power Supply (2/3) ...........................................................................................7
2.1.3 Power Supply (3/3) ...........................................................................................8
2.1.4 USB Trouble (1/2) .............................................................................................9
2.1.5 USB Trouble (2/2) ......................................................................................... 10
2.1.6 LCD Screen Trouble (1/2) ............................................................................. 11
2.1.7 LCD Screen Trouble (2/2) ............................................................................. 12
2.1.8 Keypad Trouble (1/2) .................................................................................... 13
2.1.9 Keypad Trouble (2/3) .................................................................................... 14
2.1.10 Keypad Trouble (3/3) .................................................................................. 15
2.1.11 RTC Trouble (1/2) ....................................................................................... 16
2.1.12 RTC Trouble (2/2) ....................................................................................... 17
2.1.13 Bill Module Trouble (1/3) ............................................................................. 18
2.1.14 Bill Module Trouble (2/3) ............................................................................. 19
2.1.15 Bill Module Trouble (3/3) ............................................................................. 20
2.1.16 Printer Trouble (1/2).................................................................................... 21
2.1.17 Printer Trouble (2/3).................................................................................... 22
2.1.18 Printer Trouble (3/3).................................................................................... 23
3. DEVICE MAINTENANCE ..................................................................................... 24
3.1 Automatic Recharger ...................................................................................... 24
3.1.1 Outline .......................................................................................................... 24
3.1.2 Structure ....................................................................................................... 24
3.1.3 Specification ................................................................................................. 25
3.1.4 Replacement Method.................................................................................... 31
3.1.5 Connector Specification ................................................................................ 38
3.2 Maintenance Flow chart .................................................................................. 50
4. AUTOMATIC RECHARGER INSTALLATION AND UPDATE ............................ 51
4.1 Automatic Recharger Installation ................................................................... 51
4.1.1 Procedure ..................................................................................................... 51
4.1.2 Device Registration....................................................................................... 52
4.1.2.1 Power ON ....................................................................................................... 52
4.1.2.2 SAM Card Mounting ....................................................................................... 53
4.1.2.3 USB Mounting Method .................................................................................... 54
CB-EDR-HM-00-V1.0
Automatic
Recharger
Page iii of All
Bogota SIRCI Project
User Requirement Definition
5. AUTOMATIC RECHARGER HEAVY MAINTENANCE ....................................... 55
5.1 CPU Board ........................................................................................................ 55
5.1.1 CPU BOARD Specification ........................................................................... 55
5.1.1.1 CPU Board Specification ................................................................................ 55
5.1.1.2 CPU Board Block Diagram ............................................................................. 55
5.1.1.3 CPU Board Check point .................................................................................. 56
5.1.2 Sub BOARD Specification ............................................................................ 57
5.1.2.1 Sub Main Board Specification ......................................................................... 57
5.1.2.2 Sub Main Board Block Diagram ...................................................................... 57
5.1.2.3 Sub Main Check point ..................................................................................... 58
CB-EDR-HM-00-V1.0
Automatic
Recharger
Page iv of All
Bogota SIRCI Project
User Requirement Definition
1. Automatic Recharger Equipment Structure
1.1
Overview
The Automatic Recharger is recharged the transit card.
1.2
External / Internal Structure and Main Module
1.2.1 External Structure
390mm (W)
440mm (D)
1500mm (H)
[Automatic Recharger]
CB-EDR-HM-00-V1.0
Automatic Recharger
Page1of All
Bogota SIRCI Project
User Requirement Definition
내
Division
용
440mm(D) x 1500mm(H) x 390mm(W)
Size
Material
BASE PLATE(SUS),
Exterior (STEEL, Painted_SLIVER)
1.2.2 Main Module Structure I
440mm (D)
390mm (W)
1)
2)
3)
1500mm (H)
Automatic Recharger
Name
1) 4.3’ LCD
2) RFID Antenna
3) Bill Module
CB-EDR-HM-00-V1.0
Explanation
Display of operation information
ISO14443 Type A, 13.56MHz card recognition and
charging
6 varieties of colombia bill
Insert each 1 bill
Automatic Recharger
Page2of All
Bogota SIRCI Project
User Requirement Definition
1.2.3 Internal Structure
CPU, SUB,
LCD Board
Bill Module
RF Antenna
Keypad
Printer
Battery
SMPS
Power Panel
CB-EDR-HM-00-V1.0
Automatic Recharger
Page3of All
Bogota SIRCI Project
User Requirement Definition
1.2.4 Main Module Structure II
1) Printer Module
Print daily closing , accounting statement.
2) RFID Antenna
13.56MHz RF Card
ISO 14443 Type A
3) CPU Board
Control all attached equipment of Automatic Recharger and transfer data to main server.
 CPU
- S3C2440(ARM9 Core) : 400MHz
 Memory
- SDRAM : 128MByte
- Nor : 8MByte
- Nand : 512Myte
 RF Module
- RC531( Type A)
4) Sub Main Board
Control I/O communicating CPU Board.
 Exterior PORT
- Ethernet : 1
- USB : 1
- RS -232 : 5
 SAM
- Socket 4EA(SIM Type)
 Sound
- SW Codec controal
- Speaker : 5W * 1
5) I/O Board
Control I/O communicating CPU Board and Sub Main Board.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page4of All
Bogota SIRCI Project
User Requirement Definition
6) Bill Module
: Recognize 6 varieties of Colombian Bill.
7) SMPS
: AC 110V,
DC24V, DC12V
8) Battery
: Operate for 2 minute by using SMPS sub power.
9) Power Panel
: Input AC120V, output AC120V
CB-EDR-HM-00-V1.0
Automatic Recharger
Page5of All
Bogota SIRCI Project
User Requirement Definition
2. Error Handling
2.1.1 Supply of the power (1/3)
CB-EDR-HM-00-V1.0
Automatic Recharger
Page6of All
Bogota SIRCI Project
User Requirement Definition
2.1.2 Power Supply (2/3)
Output Voltage
AC 110V
Check

Output Voltage
DC12V Check

Output Voltage
DC12V Check

CB-EDR-HM-00-V1.0
Automatic Recharger
Page7of All
Bogota SIRCI Project
User Requirement Definition
2.1.3 Power Supply (3/3)
Fuse(F1) Check
U3 Output 5V Check
U5 Output 5V Check
U2 Output 8V Check
U28 Output 3.3V
Check
U1 Output 5V Check
U4 Output 3.3V Check
CB-EDR-HM-00-V1.0
Automatic Recharger
Page8of All
Bogota SIRCI Project
User Requirement Definition
2.1.4 USB Trouble (1/2)
Cannot update USB
FAIL
Check USB Memory
- Replace USB Memory stick
from PC
PASS
FAIL
Check USB file system
(FAT32 is not
Format USB by FAT file system
PASS
FAIL
Check CPU board USB
- Replace CPU PCB
host controller IC(U12)
PASS
Check USB power
FAIL
- Replace SUB Main PCB
PASS
FAIL
Check USB Cable
- Replace USB Cable
PASS
No trouble
CB-EDR-HM-00-V1.0
Automatic Recharger
Page9of All
Bogota SIRCI Project
User Requirement Definition
2.1.5 USB Trouble (2/2)
Check of U21 USB
Controller
Check USB Power
Pin No. 1 5V
Check USB Cable
CB-EDR-HM-00-V1.0
Automatic Recharger
Page10of All
Bogota SIRCI Project
User Requirement Definition
2.1.6 LCD Screen Trouble (1/2)
CB-EDR-HM-00-V1.0
Automatic Recharger
Page11of All
Bogota SIRCI Project
User Requirement Definition
2.1.7 LCD Screen Trouble (2/2)
Check LCD Data &
Power Line (Sub Main)
Check LCD Data &
Power Line (LCD B/D)
Check LCD FFC Cable
Check LCD
Check LCD Board
CB-EDR-HM-00-V1.0
Automatic Recharger
Page12of All
Bogota SIRCI Project
User Requirement Definition
2.1.8 Keypad Trouble (1/2)
CB-EDR-HM-00-V1.0
Automatic Recharger
Page13of All
Bogota SIRCI Project
User Requirement Definition
2.1.9 Keypad Trouble (2/3)
Check CPU Board
Key Data Line
& Power Line
Check FFC
Cable
Check SUB Board Key
Data Line & Power
Line
CB-EDR-HM-00-V1.0
Automatic Recharger
Page14of All
Bogota SIRCI Project
User Requirement Definition
2.1.10 Keypad Trouble (3/3)
Check I/O
Connector Cable
Check I/O Board
Key Data Line &
Power Line
Check Keypad
Cable
Check Keypad
Key Data Line &
Power Line
CB-EDR-HM-00-V1.0
Automatic Recharger
Page15of All
Bogota SIRCI Project
User Requirement Definition
2.1.11 RTC Trouble (1/2)
CB-EDR-HM-00-V1.0
Automatic Recharger
Page16of All
Bogota SIRCI Project
User Requirement Definition
2.1.12 RTC Trouble (2/2)
Check RTC Battery
Check RTC IC
CB-EDR-HM-00-V1.0
Automatic Recharger
Page17of All
Bogota SIRCI Project
User Requirement Definition
2.1.13 Bill Module Trouble (1/3)
Bill Module Trouble
CB-EDR-HM-00-V1.0
Automatic Recharger
Page18of All
Bogota SIRCI Project
User Requirement Definition
2.1.14 Bill Module Trouble (2/3)
Check Bill Module
Check Data Cable
CB-EDR-HM-00-V1.0
Automatic Recharger
Page19of All
Bogota SIRCI Project
User Requirement Definition
2.1.15 Bill Module Trouble (3/3)
Check I/O Board
Data line
Check I/O Connecter
Check UART Chip
(U10)
CB-EDR-HM-00-V1.0
Automatic Recharger
Page20of All
Bogota SIRCI Project
User Requirement Definition
2.1.16 Printer Trouble (1/2)
Printer Trouble
CB-EDR-HM-00-V1.0
Automatic Recharger
Page21of All
Bogota SIRCI Project
User Requirement Definition
2.1.17 Printer Trouble (2/3)
Check Printer
Check Data Cable
Check I/O Board
Data line
CB-EDR-HM-00-V1.0
Automatic Recharger
Page22of All
Bogota SIRCI Project
User Requirement Definition
2.1.18 Printer Trouble (3/3)
Check I/O Connecter
Check UART Chip
(U10, U18)
CB-EDR-HM-00-V1.0
Automatic Recharger
Page23of All
Bogota SIRCI Project
User Requirement Definition
3. Device Maintenance
3.1 Automatic Recharger
3.1.1 Outline
3.1.2 Structure
CPU, SUB,
LCD Board
Speaker
Bill Module
Antenna
Keypad
Printer
SMPS
Battery
Power Panel
CB-EDR-HM-00-V1.0
Automatic Recharger
Page24of All
Bogota SIRCI Project
User Requirement Definition
3.1.3 Specification
1) CPU Specification
CPU Board is the core board and plays main program also control the
communication of module.
ETHERNET
EXT_UART
RC531
USB
Controller IC
NAND FLASH
S3C2440
NOR FLASH
SDRAM
 CPU
- S3C2440(ARM9 Core) : 400MHz
 Memory
- SDRAM : 128MByte
- Nor : 8MByte
- Nand : 512Myte
 RF Module
- RC531 (Type A)
 EXT_UART
- SB16C554A
 USB Controller
- UBI9033
CB-EDR-HM-00-V1.0
Automatic Recharger
Page25of All
Bogota SIRCI Project
User Requirement Definition
 ETHERNET
- W5100 (WIZNET)
2) SUB Main Board Specification
Communicate with CPU Board and control various I/O device.
AC97 Codec
CB-EDR-HM-00-V1.0
Automatic Recharger
Page26of All
Bogota SIRCI Project
User Requirement Definition
POWER PART
Power
Ethernet
RS-232
USB
SIM Slot
Debug
 Exterior PORT
- Ethernet : 1
- USB : 1
- RS -232 : 5
: Printer 1, Bill Module1, RFID Reader1, Debug 1, Spare Port 1
 SAM
- Socket 4EA(SIM Type)
 Sound
- SW Codec control
- Speaker : 5W * 1
 Input Power
- DC12V Input
CB-EDR-HM-00-V1.0
from
I/O Board
Automatic Recharger
Page27of All
Bogota SIRCI Project
User Requirement Definition
3) I/O Board Specification
Communicate with CPU Board, Sub main board and control I/O device.
Senor Connecter
I/O Connecter
KEYPAD Connecter
Inside Lamp Connecter
Printer Connecter
Power Part
Bill Module Connecter
RFID Module Connecter
Spare RS-232 Connecter
Power Signal Connecter
Antenna LED Connecter
Main Power Connecter
Sub Main Power Connecter
4) Antenna Board Specification
Recognize card connecting CPU Board RC531.
5) Keypad Specification
CB-EDR-HM-00-V1.0
Automatic Recharger
Page28of All
Bogota SIRCI Project
User Requirement Definition
Transfer entered Key value through I/O Board to CPU Board.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page29of All
Bogota SIRCI Project
User Requirement Definition
6) SMPS and Battery Specification
- SMPS : Supplied power from Power Panel and output DC 12/24V.
- Battery : 140W(Max) for 2minute.
7) Power Panel Specification
- Supply power from outside power.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page30of All
Bogota SIRCI Project
User Requirement Definition
3.1.4 Replacement Method
1) CPU Board Separation
① Unfasten the screw which is fixed to Sub Main Bracket and let down it.
② Remove 40Ping FFC cable which is connecting LCD Board and let it down in
direction of arrow.
③ Remove 30Pin FFC cable and Antenna Cable which is connecting Sub Main Board.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page31of All
Bogota SIRCI Project
User Requirement Definition
④ Unfasten fixed screw which is connecting Sub Main Board and separate Sub
Main Board.
2) Sub Main Board Separation
① Unfasten fixed screw which is connecting Sub Main Bracket and separate
Sub main Board.
② Separate Connector which is connecting Sub Main Board.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page32of All
Bogota SIRCI Project
User Requirement Definition
3) I/O Board Separation
① Unfasten fixed screw connecting I/O Cover and separate in direction of arrow.
② Remove connector connecting I/O Board.
③ Unfasten fixed screw which is connecting I/O Board and separate it.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page33of All
Bogota SIRCI Project
User Requirement Definition
4) KEYPAD Board Separation
① Remove Connector which is connecting.
② Separate fixed screw which is connecting KEYAPAD and separate KEYPAD.
5) PRINTER Separation
① Separate Connector which is connecting Printer.
② Unfasten fixed screw which is
Connected to exterior mechanism
and separate it.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page34of All
Bogota SIRCI Project
User Requirement Definition
6) BILL MODUEL Separation
① Pull Silver Bar of Bill Module up and separate it in the direction of red arrow.
② Hold the bottom of Bill Module PCB and pull forward.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page35of All
Bogota SIRCI Project
User Requirement Definition
7) SMPS 및 BATTERY Separation
① Separate Connector which is connecting SMPS and Battery.
② Unfasten fixed screw which is connecting to exterior and pull forward.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page36of All
Bogota SIRCI Project
User Requirement Definition
8) POWER PANEL Separation
Separate the fixed screw which is connected device.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page37of All
Bogota SIRCI Project
User Requirement Definition
3.1.5 Connector Specification
1) USB2.0 Cable
CON '1’
(USB2.0)
Color
CON '2’
(Sub Board J13)
2) Speaker Cable
CON '1’
'(Sub Board J11,J12)
Color
WHITE
CON '2’'
(66SF03N5W 4ohm)
BLACK
3) Inside Lamp Cable
CB-EDR-HM-00-V1.0
Automatic Recharger
Page38of All
Bogota SIRCI Project
User Requirement Definition
CON '1'
(Connecter Board J3)
Color
CON '2'
(INSIDE LAMP)
12V
GND
4) Main Door_SW Cable
CON '1'
(Main Door_SW)
Color
BLACK
CON '2'
(Connecter
Board_J4)
RED
WHITE
CB-EDR-HM-00-V1.0
Automatic Recharger
Page39of All
Bogota SIRCI Project
User Requirement Definition
5) SUB DOOR, CASH BOX S/W Cable
CON '1'
(SUB Door_SW)
Color
COM
BLACK
CON '2'
(Connecter
Board_J6)
N. O
WHITE
CON '3'
(CASH BOX_SW)
Color
COM
BLACK
CON '4'
(Connecter
Board_J9)
N. O
WHITE
6) MAIN IF Cable
CB-EDR-HM-00-V1.0
Automatic Recharger
Page40of All
Bogota SIRCI Project
User Requirement Definition
CON '2'
(Connecter
Board_J1)
….
….
39
39
40
40
CON '1'
(SUB Board_J25)
Color
7) Main Serial Cable
CON '1'
(SUB Board_J16)
Color
CON '3'
(Connecter
Board_J7)
CON '2'
(SUB Board_J16)
CB-EDR-HM-00-V1.0
CON '3'
(Connecter
Board_J7)
Color
Automatic Recharger
Page41of All
Bogota SIRCI Project
8)
User Requirement Definition
Main Power Cable
CON '1'
(Connector Board_J17)
Color
CON '2'
(Sub Board_J3)
9) Antenna Cable
CON '1'
(CPU Board_J23)
Color
CON '2'
(Antenna Board_J1)
RED
WHITE
BLACK
CB-EDR-HM-00-V1.0
Automatic Recharger
Page42of All
Bogota SIRCI Project
10)
User Requirement Definition
Antenna LED Cable
CON '1'
(LED Board)
Color
CON '2'
(Connecter Board_J12)
WHITE
BLACK
Color
CON '2'
(Connecter Board_J2)
11) KEYPAD Cable
CON '1'
(KEYPAD Board)
CB-EDR-HM-00-V1.0
…
…
29
29
30
30
Automatic Recharger
Page43of All
Bogota SIRCI Project
User Requirement Definition
12) Printer Cable
CON '1'
(Connector Board J8)
Color
CON '2'
(PRINTER_PWR)
RED
BLACK
CON '1'
(Connector Board J8)
Color
CON '2'
(PRINTER_PWR)
BLACK
ORANGE
YELLOW
GREEN
BLUE
10
PINK
CB-EDR-HM-00-V1.0
Automatic Recharger
Page44of All
Bogota SIRCI Project
User Requirement Definition
13) BILL RFID READER Cable
CON '1'
(Connector Board J10)
Color
CON '2'
(BILL RFID)
RED
BLACK
BLUE
WHITE
CON '1'
(Connector Board J5)
Color
CON '2'
(BILL Module)
BLACK
WHITE
11
BLACK
RED
GREEN
12
14) BILL Module Cable
CB-EDR-HM-00-V1.0
Automatic Recharger
Page45of All
Bogota SIRCI Project
User Requirement Definition
15) LAN Cable
CON '1'
(RJ-45)
CON '2'
(RJ-45)
Color
16) Power Signal Cable
CON '1'
(Connector Board J11)
Color
CON '2'
(SMPS SIGNAL)
RED
BLACK
BLUE
WHITE
CB-EDR-HM-00-V1.0
Automatic Recharger
Page46of All
Bogota SIRCI Project
User Requirement Definition
17) Power Input Cable
CON '1'
(Connector Board J19)
Color
CON '2'
(Sub Main)
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
RED
RED
WHITE
10
WHITE
10
11
WHITE
11
12
WHITE
12
CB-EDR-HM-00-V1.0
Automatic Recharger
Page47of All
Bogota SIRCI Project
User Requirement Definition
18) AC Input Cable
CON '1'
(SMPS AC IN)
Color
CON '2'
(POWER_AC OUT)
BROWN
Greenish
yellow
BLUE
F. G
AC_N
19) Battery Cable
CON '1'
(SMPS BATT_OUT)
Color
CON '2'
(BATTERY)
RED
VCC
BLACK
GND
20) RFID Cable
CB-EDR-HM-00-V1.0
Automatic Recharger
Page48of All
Bogota SIRCI Project
User Requirement Definition
CON '1'
(SMPS BATT_OUT)
Color
CON '2'
(BATTERY)
Red
Red
BLACK
BLACK
BLUE
BLUE
WHITE
WHITE
21) FREME Ground
CB-EDR-HM-00-V1.0
Automatic Recharger
Page49of All
Bogota SIRCI Project
User Requirement Definition
3.2 Maintenance Flow chart
Error
Receive replacement
parts
Check ERROR CODE
Check maintenance
referral and ERROR CODE
Device maintenance
and replacement due to
MANUAL
Device repair due to
MANUAL
Conduct
TEST
Conduct
TEST
OK
NO
OK
NO
Repair complete
Repair complete
1) Tool : Screwdriver, Tester
2) Notice
- Check each part of the adjustment value for every 12months or in a tim
ely
manner.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page50of All
Bogota SIRCI Project
User Requirement Definition
3) Detail check items
Inspection cycle
No
Items
month
Power/Voltage Check
Operation of Printer
Operation of KEYPAD
Check of LCD Operation
Check of SMPS Operation
Check of BATTERY Operation
Check of BILL MODULE Operation
Check of POWER panel Operation
3months
6months
12months
Remarks
4. Automatic Recharger Installation and update
4.1 Automatic Recharger Installation
4.1.1 Procedure
No
Division
Device
registration
1) Power ON
2) SAM Mounting Method
3) USB Mounting Method
…
…
…
CB-EDR-HM-00-V1.0
비고
Contents
…
Automatic Recharger
Page51of All
Bogota SIRCI Project
User Requirement Definition
4.1.2 Device Registration
4.1.2.1 Power ON
① Power Panel Power S/W ON
② SMPS Power S/W ON, Battery S/W ON
③ Sub Main Board S/W ON
CB-EDR-HM-00-V1.0
Automatic Recharger
Page52of All
Bogota SIRCI Project
User Requirement Definition
4.1.2.2 SAM Card Mounting

Push the SAM slot like Picture 1 and lift the cover in direction of the arrow like
picture
②


Combine the SAM card like picture 3 and push and fix SAM Slot in direction of the
arrow like picture 4.
③
Insert the rest of 3 slots using same method.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page53of All
Bogota SIRCI Project
User Requirement Definition
4.1.2.3 USB Mounting Method
①
②
Turn off the module
Insert USB to USB PORT and power on
CB-EDR-HM-00-V1.0
Automatic Recharger
Page54of All
Bogota SIRCI Project
User Requirement Definition
5. Automatic Recharger Heavy Maintenance
5.1 CPU Board
5.1.1 CPU BOARD Specification
5.1.1.1 CPU Board Specification
CPU Board : Main board of the attended recharger and operate main program so that
control all of module communication and function.
Division
CPU
Memory
RF Module
Specification
Remarks
S3C24440
SDRAM : 128MByte
Nor Flash : 8MByte
Nand Flash : 512 MByte
ISO 14443 Type A
5.1.1.2 CPU Board Block Diagram
CB-EDR-HM-00-V1.0
Automatic Recharger
Page55of All
Bogota SIRCI Project
User Requirement Definition
5.1.1.3 CPU Board Check point
- KEYPAD
T P100
T P101
T P102
T P103
T P104
T P105
T P106
T P107
T P108
T P109
T P110
T P111
T P112
T P113
T P114
T P115
T P116
T P117
T P118
T P119
T P120
Test Point
M5.0V
M_#KEY_IRQ1
KEY_5.0V
C116
100nF
C-1608
3_I
2_I
1A
1Y
2A
2Y
3A
3Y
GND
VCC
6A
6Y
5A
5Y
4A
4Y
14
13
12
11
10
M_#KEY_IRQ1
1K
5K
CORRECTION
10K
MENU
KIND
CANCEL
PAYMENT
REFUND
OK
U107
74HC14D
SOIC14(P1.27-W7.0)\74HC14D
J100
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
DST520-030
DST520-030
① Circuit description
: Invert input signal and send it to CPU.
(Check other signal’s frame is same as others or not.)
② Waveform measurements

CB-EDR-HM-00-V1.0
Automatic Recharger
Page56of All
31
32
Bogota SIRCI Project
User Requirement Definition
5.1.2 Sub BOARD Specification
5.1.2.1 Sub Main Board Specification
- Communicated with CPU Board and control I/O.
Ariticle
CPU
Memory
RF Module
Specification
Remarks
S3C24440
SDRAM : 128MByte
Nor Flash : 8MByte
Nand Flash : 512 MByte
ISO 14443 Type A
5.1.2.2 Sub Main Board Block Diagram
CB-EDR-HM-00-V1.0
Automatic Recharger
Page57of All
Bogota SIRCI Project
User Requirement Definition
5.1.2.3 Sub Main Check point
- RS-232
TX Test Point
VDD_3.3V
TC3
U9
C37
[3] DBG_TX
[3] CUSTOM_TX
[3] DBG_RX
[3] CUSTOM_RX
DBG_TX
R86
R89
100R
100R
R-1005
R-1005
DBG_RX
R92
R94
100R
100R
R-1005
R-1005
100nF 1
C1+
VCC
C-1005
C1100nF 4
C2+
V+
C-1005
C2V11
T1IN
T1OUT
10
T2IN T2OUT
12
9 R1OUT R1IN
R2OUT R2IN
15
GND
16
C38
C39
C40
14
R87
13 R93
10uF/16V
TC-3216-A
100nF
C-1005
C36
100nF
C-1005
100nF
C-1005
1K R-1005
R91
1K R-1005
1K
R95
VDD_3.3V
CPU DEBUGER
R88
100R R-1005
R90
100R R-1005
R-1005
1K R-1005
J7
TSH-3813
STEREO-JACK-SH381D-PA9T-A
SP3232EY
TSSOP16
RX Test Point
③ Circuit description
: Change UART signal into RS -232 signal
④
Waveform measurements
< Normal TX waveform >
CB-EDR-HM-00-V1.0
Automatic Recharger
Page58of All
Bogota SIRCI Project
User Requirement Definition
< Normal TX waveform >
- SIM Part (Clock)
SAM5.0V
SAM5.0V
Y1
C47
100nF
C-1608
VCC
OUT
R124
1K
R-1608
SIM_CLK1
GND
3.6864MHz(SCO-105)
SAM5.0V
SAM5.0V
Y3
C86
100nF
C-1608
R1002
Z_0R
R-1608
VCC
OUT
R201
1K
R-1608
R1003
0R R-1608
SIM_CLK2
GND
3.6864MHz(SCO-105)
①
Test Point
Circuit description
: Circuit that supply the stable Clock to allow SIM Card to operate.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page59of All
Bogota SIRCI Project
②
User Requirement Definition
Waveform measurements

- SIM Part (Signal)
SAM5.0V
Q1
R125
10K
R-1608
SI2301DS(SOT-23)
R126
10K
SIM_PWR_ON1_5V R129
1K
R-1608
SIM_RX1_A
R134
R136
C48
100nF
C-1608
GND
R-1608
100R
100R R-1608
D4
SD103B(SOD123)
Q3
Z_MMBT3904(SOT-23)
SIM_TX1_A
R127
R128
1K
1K
R-1608 R-1608
SIM_RESET_ON1_5V
SIM_CLK1
ZD1
Z_L16513
C50
30pF
C-1608
SM1
VCC
RST
CLK
SIO
S1
GND
VPP
FU1
FU2
S2
10
C51
DRC017S
Z_10pF
C-1608
SIM SOCKET #1
Test Point
① Circuit description
: Circuit that realize to recognize SIM CARD
CB-EDR-HM-00-V1.0
Automatic Recharger
Page60of All
Bogota SIRCI Project
User Requirement Definition
② Waveform measurements

CB-EDR-HM-00-V1.0
Automatic Recharger
Page61of All
Bogota SIRCI Project
User Requirement Definition
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference. and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
Any changes or modifications to the equipment not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
CB-EDR-HM-00-V1.0
Automatic Recharger
Page62of All

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : JJ
Create Date                     : 2012:05:23 12:02:48+09:00
Modify Date                     : 2012:05:23 12:02:48+09:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.4.2 (Windows)
Format                          : application/pdf
Title                           : Microsoft Word - Manual.doc
Creator                         : JJ
Document ID                     : uuid:788d0f9c-9283-4c7a-87b2-55270882801c
Instance ID                     : uuid:62a2f491-cd7f-4d5b-8a85-f2c002b052f9
Page Count                      : 67
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RTQKSCCCBR400A

Navigation menu