Landis Gyr Technologies HUNTSU825 3G S4e Gridstream User Manual 98 9103
Landis+Gyr Technologies, LLC 3G S4e Gridstream 98 9103
Contents
- 1. Exhibit D - Product Ship Sheet
- 2. Manual
Exhibit D - Product Ship Sheet
3G S4e Gridstream Endpoint with ZigBee Data Sheet General The 3G S4e Gridstream endpoint is designed to accommodate Landis+Gyr S4e poly-phase meters for use in commercial and light industrial services. The S4e Advanced Function meter is an Active Energy kWh/kW/TOU Meter. The meter features Digital Multiplication Measurement Technique, meets ANSI standards for performance and utilizes ANSI C12.19 protocol (between meter and AMR device). Can be deployed with or without ZigBee. Display Options • Energy Metrics: +kWh, -kWh, Net kWh, and added kWh (Security). Figure 1. The 3G S4e Gridstream Endpoint Module and the Landis+Gyr S4e Meter FCC Compliance Information Model: FASY-0825 FCCID: TEB-HUNTSU825 IC: 5931A-HUNTSU825 Landis+Gyr Confidential Information 98-9103 Rev AA 3G S4e Gridstream Endpoint with ZigBee Data Sheet Landis+Gyr Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Landis+Gyr could void the user’s authority to operate the equipment. Endpoint Location To comply with FCC’s RF exposure limits for general population/uncontrolled exposure, the antenna(e) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Endpoint Usage The 3G S4e Gridstream endpoint will be used: • for commercial and light industrial metering applications. • at homes and businesses. The 3G S4e Gridstream endpoint requires professional installation by qualified personnel. RF Interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the meter off, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Consult Landis+Gyr or an experienced radio/TC technician for help. 98-9103 Rev AA Landis+Gyr Confidential Information Landis+Gyr 3G S4e Gridstream Endpoint with ZigBee Data Sheet Required Software To work with the endpoint, you need one of the following software tools: • Command Center ver. 4.1 or greater • RadioShop. • Network Configuration Manager. • Landis+Gyr 1132Prog application. • Endpoint Testing Manager. • Endpoint Implementation Manager. Specifications Table 1. 3G S4e Gridstream Endpoint Specifications Category Specification Value or Range Form Compatible Meters Electrical RF 900 MHz RF ZigBee Landis+Gyr Confidential Information Landis+Gyr S4e Supported Meter Forms Class Form Class 3S 20 16SE 320 5S/45S 20 16/15K 480 6S/36S 20 9S/8S 20 2S 200 12S 200 16S/15S 200 25S 200 12SE 320 Voltage 10.5-13.5V (from the meter’s power supply) Power Max: 2.5W Typical: 0.5W Output Power +26 dBm +/-1 dBm Adjacent Channel Power 39 dBc Nominal Transmit Frequency 902 to 928 MHz ISM unlicensed (FCC Part 15) Communication Protocol Gridstream Protocol for Command Center Receive Sensitivity -108 dBm minimum Output Power +20 dBm +/-1 Adjacent Channel Power 40 dBc Minimum Transmit Frequency 2405-2480 MHz Communication Protocol ZigBee Protocol Receive Sensitivity -104 dBm minimum 98-9103 Rev AA 3G S4e Gridstream Endpoint with ZigBee Data Sheet Landis+Gyr Table 1. 3G S4e Gridstream Endpoint Specifications Category Standards Compliance Environmental Mechanical Specification Value or Range FCC Title 47 CFR Part 15 Radiated and Conducted Emissions (incl. intentional radiators) IEC 61000 4-2,3,4,5,11,12 Electromagnetic Compatibility ANSI C12.19 Compatible with Utility Industry End Device Tables ANSI C12.20 National Standard for Electricity Meters - 0.2 and 0.5 Accuracy Classes ANSI C12.21 Code for Electricity Metering ANSI C37.90.1 (1989) Standard Surge Withstand Capability (SWC) Tests ANSI C12.22 Transport of ANSI C12.19 Over Network Transmissions General Environmental Outdoor, rain-protected, sunlight-exposed Operating Temperature Range -40 to +70 C (under meter glass) Humidity 0 to 95% relative humidity, non-condensing Size Weight Contact Information Technical Support: Internet: Fax E-mail: 1-888-390-5733 www.landisgyr.com 1-218-562-5530 solutionsupport.na@landisgyr.com 98-9103 Rev AA Landis+Gyr Confidential Information
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Mode : UseNone XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Create Date : 2001:06:20 16:18:34Z Creator Tool : FrameMaker 9.0 Modify Date : 2009:10:16 13:58:31-05:00 Metadata Date : 2009:10:16 13:58:31-05:00 Producer : Acrobat Distiller 9.0.0 (Windows) Format : application/pdf Title : 98-9103.fm Document ID : uuid:e19affc6-00be-4088-ae0d-35efdc21e250 Instance ID : uuid:c6bd5ff5-b78d-4f10-bcfc-45281d8c8d80 Page Count : 4 Creator : FrameMaker 9.0EXIF Metadata provided by EXIF.tools