Landis Gyr Technologies HUNTSU825 3G S4e Gridstream User Manual 12 0333 Exhibit Cover
Landis+Gyr Technologies, LLC 3G S4e Gridstream 12 0333 Exhibit Cover
Contents
- 1. Exhibit D - Product Ship Sheet
- 2. Manual
Manual
Certification Exhibit FCC ID: TEB-HUNTSU825 FCC Rule Part: 15.247 ACS Project Number: 12-0333 Manufacturer: Landis+Gyr Technologies, LLC Model: 0825 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Draft 5.8.13 Gridstream RF S4e Endpoint with ZigBee Data Sheet Publication: 98-9103 Rev AA LANDIS+GYR CONFIDENTIAL INFORMATION Draft 5.8.13 Limitation on Warranties and Liability Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr. In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost profits) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages. © 2013 Landis+Gyr, Inc. All Rights Reserved Gridstream RF S4e Endpoint with ZigBee Data Sheet Publication: Pubs Number Goes Here Revision History Modification Date 05/08/2013 Landis+Gyr 6436 County Road 11 Pequot Lakes, MN 56472 Website: www.landisgyr.com E-mail: solutionsupport.na@landisgyr.com Technical Support: 1-888-390-5733 Revision AA Description Pending Author Kim Utesch © 2013 Landis+Gyr All rights reserved. 5.8.13 GridstreamDraft RF S4e Endpoint with ZigBee Data Sheet General The Gridstream RF S4e endpoint is designed to accommodate Landis+Gyr S4e poly-phase meters for use in commercial and light industrial services. The S4e Advanced Function meter is an Active Energy kWh/kW/TOU Meter. The meter features Digital Multiplication Measurement Technique, meets ANSI standards for performance and utilizes ANSI C12.19 protocol (between meter and AMR device). Can be deployed with or without ZigBee. Figure 1. The Gridstream RF S4e Endpoint Module and the Landis+Gyr S4e Meter FCC Compliance Information Models: 0825, 26-1554, 26-1557 FCC ID: TEB-HUNTSU825 IC: 5931A-HUNTSU825 Data Sheet 98-9103 Rev AA Draft 5.8.13 Gridstream RF S4e Endpoint with ZigBee Data Sheet Landis+Gyr Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by Landis+Gyr could void the user’s authority to operate the equipment. Endpoint Location To comply with FCC’s RF exposure limits for general population/uncontrolled exposure, the antenna(e) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Industry Canada This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter (5931A-HUNTSU825) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Approved Antenna: Omni-directional antenna, 5.5 dBi gain, 902-928 MHz, antenna impedance is 50 ohms. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. \98-9103 Rev AA Data Sheet Draft 5.8.13 Landis+Gyr Gridstream RF S4e Endpoint with ZigBee Data Sheet Le présent émetteur radio (5931A-HUNTSU825) a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. Endpoint Usage The Gridstream RF S4e endpoint will be used: • for commercial and light industrial metering applications. • at homes and businesses. The Gridstream RF S4e endpoint requires professional installation by qualified personnel. RF Interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the meter off, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Consult Landis+Gyr or an experienced radio/TC technician for help. Required Software To work with the endpoint, you need one of the following software tools: Data Sheet • Command Center host ver. 4.1 SP2 or greater • RadioShop • Landis+Gyr 1132Prog application • Endpoint Testing Manager 98-9103 Rev AA Draft 5.8.13 Gridstream RF S4e Endpoint with ZigBee Data Sheet Landis+Gyr Communication Module Specifications Table -1. Gridstream RF S4e Communications Module Specifications Category Compatible Meters Specification Value or Range Landis+Gyr S4e Supported Meter Forms RF ZigBee Standards Compliance Class Form Class 3S 20 16SE 320 5S/45S 20 16/15K 480 6S/36S 20 9S/8S 20 2S 200 12S 200 16S/15S 200 25S 200 12SE 320 Voltage 10.5-13.5V (from the meter’s power supply) Power Max: 2.5W Typical: 0.5W Output Power +26 dBm +/-1 dBm Adjacent Channel Power 39 dBc Nominal (9600 bps) Transmit Frequency 902 to 928 MHz ISM unlicensed (FCC Part 15) Communication Protocol Gridstream Protocol for Command Center Receive Sensitivity -108 dBm minimum Output Power +20 dBm +/-1 Adjacent Channel Power 40 dBc Minimum Transmit Frequency 2405-2480 MHz Communication Protocol ZigBee Protocol Receive Sensitivity -104 dBm minimum FCC Title 47 CFR Part 15 Radiated and Conducted Emissions (incl. intentional radiators) IEC 61000 4-2,3,4,5,11,12 Electromagnetic Compatibility ANSI C12.19 Compatible with Utility Industry End Device Tables ANSI C12.20 National Standard for Electricity Meters - 0.2 and 0.5 Accuracy Classes ANSI C12.1 Code for Electricity Metering ANSI C37.90.1 (1989) Standard Surge Withstand Capability (SWC) Tests ANSI C12.22 Transport of ANSI C12.19 Over Network Transmissions Electrical RF 900 MHz Form \98-9103 Rev AA Data Sheet Draft 5.8.13 Landis+Gyr Gridstream RF S4e Endpoint with ZigBee Data Sheet Table -1. Gridstream RF S4e Communications Module Specifications (Continued) Category Environmental Data Sheet Specification Value or Range General Environmental Outdoor, rain-protected, sunlight-exposed Operating Temperature Range -40 to +85 C (under meter cover) Humidity 0 to 95% relative humidity, non-condensing 98-9103 Rev AA Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Publication: 98-1245 Rev AA LANDIS+GYR CONFIDENTIAL INFORMATION Limitation on Warranties and Liability Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr. In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost profits) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages. All brands and product names are the trademarks or registered trademarks of their respective holders. © 2013 Landis+Gyr, Inc. All Rights Reserved Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Publication: 98-1245 Revision History Modification Date Revision 3/26/2013 AA Landis+Gyr 30000 Mill Creek Avenue Alpharetta, GA 30022 Website: www.landisgyr.com E-mail: solutionsupport.na@landisgyr.com Technical Support: 1-888-390-5733 Description Released © 2013 Landis+Gyr All rights reserved. Author Vicky Costello Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Overview This publication outlines the procedure for remote passive antenna installation on Gridstream RF Electric Endpoints. Figure 1. Remote Passive Antenna This antenna couples radio frequency energy from a Landis+Gyr Gridstream RF Electric Endpoint's 902-928 MHz antenna into a coax cable connected to a remote antenna located at an optimal location for better connection to the Gridstream RF network. Coupling loss (including the 2.5 ft. cable) ranges from 5 to 9 dB, with 5 being a typical value. Environmental performance is rated for: 0 to 95% relative humidity, -40 to +85° C. Coupler Part Numbers The same coupler is used for all remote antenna installations. The part number and description is as follows: • 40-1705 flex loop, 2.5 ft. antenna cable, cable tie, adhesive In the case where the length above is insufficient, Landis+Gyr recommends the extension cable listed below, terminated with a female “N” connector on one end and a male “N” connector on the other: • 19-1742, extension cable, 20 ft. Landis+Gyr Confidential Information 98-1245 Rev AA Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Landis+Gyr Required Materials The following materials are required to complete a remote antenna installation. • Alcohol wipes • RTV - Part Number 30-0109, Dow Corning #839 • Cold flow sealing tape • Hardware, appropriate to installation • 45-1221, Kit, Antenna (consisting of items listed below) • 106119-000 Remote Antenna, 5dBi Whip • 28-1012, Antenna Ground Plane • 16-0214: Barrel Connector N-Female to N-Female, “Bulkhead” List of Terms The following is a list of terms used to identify remote antennas and related equipment. Coupling Antenna This is the flexible circuit that is at the end of the antenna assembly. It is referred to interchangeably as the flex circuit, flex dipole, patch antenna, coupler, and so on. Remote Antenna Refers to the omni whip antenna which will be “remoted” from the coupling antenna. The remote antenna is ideally mounted “line of sight” to the Gridstream RF Mesh network. Optional Materials The following items may be required, depending on the installation. • 22-1542: Grommet, 1.25” OD, 1.0” ID with 0.25” center hole • Mounting brackets, Landis+Gyr part numbers: • 28-1800: Bracket, antenna, meter box, right • 28-1801: Bracket, antenna, meter box, left • 28-1802: Bracket, antenna, ceiling mount • 28-1804: Bracket, antenna, wall, flat Tools The following tools may be required, depending on the installation. • • • Flat head screwdriver • Utility knife • Battery-operated drill with 5/8- and 1-inch • high speed metal bits 98-1245 Rev AA Phillips head screwdriver Wire cutters Tape measure Landis+Gyr Confidential Information Landis+Gyr Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Performance Table 1. Performance Parameter Minimum Frequency 902 Typical Maximum Units 928 MHz dB Coupling Loss Polarization Linear VSWR 1.78:1 Impedance 50 ohm Input RL 11 dB Condition Final antenna assembly on FOCUS AX: modular Final antenna assembly on FOCUS AX: modular General Installation Guidelines Determine the optimum location for remote antenna installation. This will vary depending on the location of the meter. In general, the antenna should be: • Installed as close to line of sight with a Gridstream RF network equipment as is possible. • Mounted so that it is at least four inches from the nearest structure. • Mounted so that a meter box cover, if the endpoint is enclosed in one, can be removed without interference from the remoted antenna. • For inside-premise installations, remoted antennas may be mounted in the proximity of an available window, or may need to be routed to the outside if the signal strength is insufficient. • Mounted so that the antenna connector is OUTSIDE the meter box. A 1-inch hole should be drilled in the meter box so that the connector can be fed through the box. Use the appropriate mounting bracket to mount the antenna external to the meter box. • Mounted so that any length of additional cable is minimized. The best practice for maximum cable length is to not exceed line loss (refer to cable manufactures line loss chart) vs. gain of antenna, the RF link loss by use of passive antenna can be excluded from the line loss calculation. It is the responsibility of local installation organizations to ensure that local wiring codes and requirements are met, including the application of a safety ground, when required. NOTE: This device and the supplied installation components are UV-resistant. Landis+Gyr Confidential Information 98-1245 Rev AA Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Landis+Gyr Gridstream RF Enhanced FOCUS AX/AX-SD Mounting Procedure NOTE: The passive antenna should be mounted within 5 mm (0.25") of the indicated location to achieve specified performance. 1. Clean the meter cover where the flex antenna will be installed. Wipe the cover mounting area with an alcohol wipe and let the area dry for one minute before proceeding with the installation. 2. Peel the paper backing off of the adhesive tape (bottom of coupling antenna). 3. Firmly press the center of the antenna to the bottom (6 o’clock position) of the meter while aligning the lower/left of center edge of the antenna with the lower edge of the window on the inner meter housing. 4. Wrap the cable tie through and over antenna guides, and around the meter. Thread the cable tie into the mating end of itself. Figure 2. Antenna Guides 5. Ensure that the cable tie is evenly placed over the antenna and cinch tight. 6. Install the remote antenna at the location indicated by the link assessment performed. If a link assessment tool is not available, select a location that provides the best line of sight to the nearest collector. 7. Once installed to the antenna, wrap the connector using cold flow tape. Tape should be wrapped tightly and in a continuous manner. The tape should cover the cable one inch past the end of the connector. 8. Secure the cable to the side of the structure using appropriate hardware for the building construction. Cable Tie Align the lower edge of the antenna with the lower edge of the bottom window on the inner meter housing, with the antenna center point as shown. Figure 3. Installation On FOCUS AX/AX-SD Meters 98-1245 Rev AA Landis+Gyr Confidential Information Landis+Gyr Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Gridstream RF Enhanced S4e Mounting Procedure NOTE: The passive antenna should be mounted within 5 mm (0.25") of the indicated location to achieve specified performance. 1. Clean the meter cover where the flex antenna will be installed. Wipe the cover area with an alcohol wipe and let the area dry one minute before proceeding with the installation. 2. Peel the paper backing off of the adhesive tape (bottom of coupling antenna). 3. Firmly press the center of the antenna onto the meter housing at the 2:30 o’clock position, 1.5 cm clockwise past the nub on the outer meter cover. Align the top edge of the antenna with the texture line on the S4e meter housing. 4. Wrap the cable tie over and through the antenna guides, and around the meter. Thread the cable tie into the mating end of itself. Figure 4. Antenna Guides 5. Ensure that the cable tie is evenly placed over the antenna and cinch tight. 6. Install the remote antenna at the location indicated by the link assessment performed. If a link assessment tool is not available, select a location that provides the best line of sight to the nearest collector. 7. Once installed to antenna, wrap the connector using cold flow tape. Tape should be wrapped tightly around the cable and in a continuous manner. The tape should cover the cable one inch past the end of the connector. Secure the cable to the side of the structure using appropriate hardware for the building construction. See Figure 5 on page 8. Landis+Gyr Confidential Information 98-1245 Rev AA Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Landis+Gyr Align the antenna center point on the meter housing at the 2:30 o’clock position, 1.5 cm clockwise past the nub on the outer meter cover Figure 5. Installation On Gridstream RF Enhanced S4e Meters Gridstream RF Integrated FOCUS AX/AX-SD Mounting Procedure NOTE: The passive antenna should be mounted within 5 mm (0.25") of the indicated location to achieve specified performance. 1. Clean the meter cover where the flex antenna will be installed. Wipe the cover mounting area with an alcohol wipe and let the area dry for one minute before proceeding with the installation. 2. Peel the paper backing off of the adhesive tape (bottom of coupling antenna). 3. Firmly press the center of the antenna to the 5 o’clock position of the meter while positioning the upper edge of the antenna 3.3 cm below the top surface of the meter cover. 4. Wrap the cable tie through and over antenna guides, and around the meter. Thread the cable tie into the mating end of itself. Figure 6. Antenna Guides 5. Ensure that the cable tie is evenly placed over the antenna and cinch tight. 98-1245 Rev AA Landis+Gyr Confidential Information Landis+Gyr Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide 6. Install the remote antenna at the location indicated by the link assessment performed. If a link assessment tool is not available, select a location that provides the best line of sight to the nearest collector. 7. Once installed to the antenna, wrap the connector using cold flow tape. Tape should be wrapped tightly and in a continuous manner. The tape should cover the cable one inch past the end of the connector. 8. Secure the cable to the side of the structure using appropriate hardware for the building construction. Cable Tie Align the antenna center point at the 5:00 position with the upper edge of the antenna 3.3 cm below the top surface of the meter cover Figure 7. Installation On FOCUS Integrated AX/AX-SD Meters Landis+Gyr Confidential Information 98-1245 Rev AA Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Landis+Gyr Antenna Brackets and Antenna Mounting Figure 8. Typical Remote Antenna Brackets 10 NOTE: To mount these brackets, use screw and bolt hardware that is approved by the local utility. 98-1245 Rev AA Landis+Gyr Confidential Information Landis+Gyr Gridstream RF Electric Endpoint Fix-up Antenna Installation Guide Grommet installed here, use RTV to Seal the meter can. Figure 9. Example Remote Antenna Illustration Landis+Gyr Confidential Information 98-1245 Rev AA 11
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 19 XMP Toolkit : 3.1-701 Producer : ScanSoft PDF Create! 7 Creator Tool : Microsoft Word - 12-0333 - Exhibit Cover.doc Create Date : 2015:01:26 09:50:28-05:00 Modify Date : 2015:01:26 09:50:34-05:00 Title : Microsoft Word - 12-0333 - Exhibit Cover.doc Creator : courtney.mcgann Author : courtney.mcgannEXIF Metadata provided by EXIF.tools