Malfunctions and Troubleshooting Fig. 115 11. Hold the elevator with one hand (→ Fig. 116‑1), loosen the locking mechanism (→ Fig. 116‑2) at the elevator and fold it back (→ Fig. 116‑3). 12. Continue to hold the elevator with one hand and remove the rack from the elevator with the other hand (→ Fig. 116‑4). Make sure that no slides slip out of the rack. 13. Now release the elevator and take the removed rack out of the instrument. Fig. 116 14. Close the locking mechanism of the elevator again (→ Fig. 117‑1) and push the elevator a few centimeters downward (→ Fig. 117‑2). 148 Version 1.2, Revision A 8 Malfunctions and Troubleshooting Fig. 117 15. Remove the needle from the parking location and insert it into the holder of the coverslip line. Make sure that the needle is positioned correctly. 16. Close the hood. Note • After initializing the instrument again, the coverslip line can be used for processing again. • If the coverslip line continues to be defective, notify Leica Service. Do not continue to use the defective coverslip line in the meantime. 8.3.3 Removing the rack from the lower area of the left elevator 1. Moving the unload drawer into removal position (rescue position) 2. Reach to the left elevator with your left hand through the unload drawer (or through the load drawer after the vessels have been removed). 3. Press the rack downwards and out of the elevator (hold the holder from below using your little finger) and push it toward the back. 4. The rack can also be removed upwards using the coverslip line and the elevator. To do so, please note the action as described in step 2. HistoCore SPECTRA CV 149 8 Malfunctions and Troubleshooting 8.3.4 Removing the rack from the oven or from behind the oven Warning • Danger of explosion! Easily flammable reagents in the oven • There is a potential for respiratory tract irritation through evaporating flammable reagents. • Caution! Hot surfaces! The oven door and the interior of the oven are hot. Avoid contact if possible to prevent burns. 1. Open access to the oven (→ Fig. 118‑1). 2. Open the oven door (→ Fig. 118‑2) fully upwards (→ Fig. 118‑3), the magnet holds the oven door in place (→ Fig. 118‑4). 3. If the rack is not attached to the gripper (→ Fig. 118‑5), the rack can be removed from the oven (→ Fig. 118‑6). Warning It is possible that the mounting medium is not yet sufficiently dried. Because of this, remove the rack only with great caution to prevent sliding of the coverglasses on the slides. 4. Store the rack safely outside the instrument. 5. Detach the oven door from the magnet carefully (→ Fig. 118‑7) and close it (→ Fig. 118‑8). Warning Close the oven door carefully to prevent crushing your hand. Note You must feel the oven door click into place in the lock. 6. Finally, close the access to the oven (→ Fig. 118‑1). 150 Version 1.2, Revision A Malfunctions and Troubleshooting Fig. 118 8.3.5 Removal of the rack from the rotator 1. Moving the unload drawer into removal position (rescue position). 2. Insert your hand carefully into the instrument and remove the rack (→ Fig. 119‑1) from the rotator (→ Fig. 119‑2). HistoCore SPECTRA CV 151 8 Malfunctions and Troubleshooting Fig. 119 8.3.6 Removal of the rack from the gripper above the rotator 1. Moving the unload drawer into removal position (rescue position). 2. Insert your hand carefully into the instrument and remove the rack from the gripper arm. To do so, grasp the handle and pull it forward, along with the rack, toward the load drawer. 8.3.7 Removal of a rack from the transfer station of the HistoCore SPECTRA ST LL If a malfunction occurs in workstation mode while the transfer device of the HistoCore SPECTRA ST transfers a rack to the HistoCore SPECTRA CV using the transfer station, the user must check where the rack is located. 1. Open the hood of the HistoCore SPECTRA ST. 2. Check whether the rack is still visible from the transfer station (→ Fig. 120‑1). Fig. 120 152 Version 1.2, Revision A Malfunctions and Troubleshooting 3. If this is the case, push the sledge (→ Fig. 121‑1) for the transfer station back into the HistoCore SPECTRA ST manually (→ Fig. 121‑2) and remove the rack (→ Fig. 121‑3) from the holder (→ Fig. 121‑4). Fig. 121 4. Following this, remove the rack from the instrument and store it safely. 5. After the instrument fault has been corrected, insert the rack in the load drawer of the HistoCore SPECTRA CV to start processing. 8.4 Replacing main fuses Warning The instrument should be shut down using the Main Switch and disconnected from the power supply in the case of a instrument failure. The main fuses can then be inspected. A suitable flat-head screwdriver must be used to prevent damage to the fuse holders. Beware of defective fuses! Potential risk of injury due to broken glass! Wear suitable protective clothing (safety goggles, cut-resistant gloves (→ P. 19 – 3.1 Standard delivery – packing list)). 1. To do so, open the hood and unscrew the two fuse holders (→ Fig. 122‑1) on the top of the right cover with a flat-head screwdriver 2. Check the fuse being used for damage. HistoCore SPECTRA CV 153 8 Malfunctions and Troubleshooting Fig. 122 3. Remove the defective fuse from the holder and replace it with a new fuse. 4. Installation occurs in the reverse sequence of operations. 154 Version 1.2, Revision A Optional Accessories and Consumables 9. Optional Accessories and Consumables 9.1 Optional accessories Designation Order No. Rack for 30 slides* (3 pcs. per package) 14 0512 52473 Handle for rack for 30 slides* (yellow, 3 pcs. per package) 14 0512 52476 Handle for rack for 30 slides* (light blue, 3 pcs. per package) 14 0512 52477 Handle for rack for 30 slides* (dark blue, 3 pcs. per package) 14 0512 52478 Handle for rack for 30 slides* (pink, 3 pcs. per package) 14 0512 52479 Handle for rack for 30 slides* (red, 3 pcs. per package) 14 0512 52480 Handle for rack for 30 slides* (green, 3 pcs. per package) 14 0512 52481 Handle for rack for 30 slides* (black, 3 pcs. per package) 14 0512 52482 Handle for rack for 30 slides* (gray, 3 pcs. per package) 14 0512 52483 Handle for rack for 30 slides* (white, 3 pcs. per package) 14 0512 52484 Reagent vessel, assembly, each consisting of 1 pc.: 14 0512 47086 Reagent vessel 14 0512 47081 Reagent vessel cover 14 0512 47085 Reagent vessel handle 14 0512 47084 Label cover S 14 0512 53748 Label cover, blank 14 0512 47323 Waste tray 14 0514 49461 Solvent container kit (2 pcs.) 14 0514 54195 Prime bottle, assembly, consisting of: 14 0514 53931 Lab bottle, 150 ml 14 0514 56202 Screw cap 14 0478 39993 Prime bottle insert 14 0514 57251 28x3 mm O-ring 14 0253 39635 Cleaning bottle 14 0514 57248 Suction cup 14 3000 00403 Rack storage rails for the unload drawer 14 0514 55967 Active carbon filter set, consisting of: 14 0512 53772 Active carbon filter 14 0512 47131 Exhaust air hose set, consisting of: 14 0514 54815 Exhaust air hose, 2 m 14 0422 31974 Hose clamp 14 0422 31973 Cut-resistant gloves, size M, 1 pair HistoCore SPECTRA CV 14 0340 29011 155 9 Optional Accessories and Consumables Designation Order No. Tool kit HistoCore SPECTRA CV, consisting of: 14 0514 54189 Screwdriver, 5.5x150 14 0170 10702 Leica brush 14 0183 30751 T16A fuse 14 6000 04696 Exhaust hose 1 set, consisting of the following: • Exhaust hose of length: 2 m • Hose clamp Order No.: 14 0422 31974 Fig. 123 Active carbon filter 1 set, consisting of 2 pcs. Order No.: 14 0512 53772 Fig. 124 Waste tray Order No.: 14 0514 49461 Fig. 125 156 Version 1.2, Revision A Optional Accessories and Consumables Needle cleaning container 1 kit, consisting of 2 pcs. Order No.: 14 0514 54195 Fig. 126 Reagent vessel Assembly, incl. reagent vessel cover Order No.: 14 0512 47086 Fig. 127 HistoCore SPECTRA CV 157 9 Optional Accessories and Consumables Racks 30 specimen slides (3 pcs. per package) Order No.: 14 0512 52473 Fig. 128 Handle for racks 30 specimen slides (3 pcs. per package) Color Order No.: Fig. 129 • • • • • • • • • yellow 14 0512 52476 light blue 14 0512 52477 dark blue 14 0512 52478 pink 14 0512 52479 red 14 0512 52480 light green 14 0512 52481 black 14 0512 52482 gray 14 0512 52483 white 14 0512 52484 Prime bottle Assembly, consisting of: • • • • Lab bottle, 150 ml Screw cap Prime bottle insert 28x3 mm O-ring Order No.: 14 0514 53931 Fig. 130 158 Version 1.2, Revision A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08 Modify Date : 2018:06:07 09:09:16+02:00 Create Date : 2018:06:07 09:09:12+02:00 Metadata Date : 2018:06:07 09:09:16+02:00 Creator Tool : Adobe InDesign CS5.5 (7.5) Format : application/pdf Title : Leica SPECTRA CV Instructions for Use, V1.2, RevA Description : 14051480101 RevA Creator : Leica Biosystems Nussloch GmbH Document ID : uuid:e00e24e5-fdec-4598-91e8-dcd0e91baa3e Instance ID : uuid:2b59accc-d53d-43d1-8fed-ead331822ec2 Producer : Adobe PDF Library 9.9 Trapped : False Page Count : 11 Author : Leica Biosystems Nussloch GmbH Subject : 14051480101 RevAEXIF Metadata provided by EXIF.tools