Lutron Electronics 0023 H-RFP-1P Central Processing Unit User Manual RF proc spec

Lutron Electronics Company Inc H-RFP-1P Central Processing Unit RF proc spec

Contents

Users Manual

Download: Lutron Electronics 0023 H-RFP-1P Central Processing Unit User Manual RF proc spec
Mirror Download [FCC.gov]Lutron Electronics 0023 H-RFP-1P Central Processing Unit User Manual RF proc spec
Document ID395961
Application IDl4/emQ3n+XGHY4RUx254cA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize59.4kB (742476 bits)
Date Submitted2004-02-11 00:00:00
Date Available2004-02-11 00:00:00
Creation Date2002-11-14 12:47:06
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2002-11-14 12:47:06
Document TitleRF proc spec.qxd
Document CreatorPScript5.dll Version 5.2
Document Author: rlau

PROCESSORS
HomeWorks Interactive TM
RF Processor
048-020 1a 11.05.02
HomeWorks® RF Processors
DESCRIPTION
HomeWorks RF Processors comprise the major communication hub
of a HomeWorks RF system. Each RF Processor will support up to 32
RF Keypads and up to 64 RF Dimmers. RF system devices communicate with the RF Processor via Radio Frequency.
Up to 4 RF Signal Repeaters may be used with each processor to
extend the range of the RF Processor.
A maximum of 16 RF processors may be connected together in a
system to support a total of 1024 RF dimmers/switches and 512
RF keypads.
MODEL NUMBERS
RF Processor
RF Processors
H-RFP-1P
H-RFP-2P
®
JOB NAME:
JOB NUMBER:
SPECIFICATION SUBMITTAL
MODEL NUMBERS:
RF Processor with 1 RS232 Port
RF Processor with 2 RS232 Ports
Page
P
HomeWorks InteractiveTM
PROCESSORS
RF Processor
048-020 2a 11.05.02
S P E C I F I C AT I O N S
Regulatory Approvals
• Battery backup will maintain programming for up to 10 years under normal
use.
• UL Listed (DC Adapter).
• Built in astronomical time clock.
• Complies with the limits for a Class B
digital device, pursuant to Part 15 of the
FCC Rules.
• Programming is done via RS-232 connection using existing HomeWorks
Interactive software.
Power
• Built in vacation and security modes.
• DC Adapter:
• Advanced keypad button programming
allowing sequences and use of conditional logic for keypad button press events.
Input power: 120/127VAC,
50/60Hz
• RS-232 port for integrating other equipment such as AV or HVAC.
Output power: 24VDC, 500mA
• Use only the DC Adapter provided by
Lutron with the RF Processor.
Key Design Features
• Field upgradeable software for the RF
processor allows additional features to
be used in the future.
• Allows installation of HomeWorks
Interactive systems in any home - new or
existing.
• Plugs into a standard electrical outlet
using the supplied DC Adapter; no high
voltage wiring necessary.
• Can be connected to an existing HWI
system or exist as a stand alone radiofrequency (RF) system.
• Fully compatible with all existing features and operation style of HomeWorks
Interactive.
• Graphical LCD with user-friendly menus
for setup and diagnostics.
• Tested to withstand electrostatic discharge without damage or memory loss,
• Durable membrane keypad for user interface.
Mounting Screw
OK
• Tested to withstand surge voltages without damage or loss of operation,in accordance with IEEE C62.41-1991
Recommended Practice on Surge Voltages
in Low-Voltage AC Power Circuits.
System Communications and Capacity
• Each RF Processor supports up to 64
HomeWorks Maestro RF dimmers/switches
or Tabletop RF Lamp dimmers.
• Each RF Processor supports up to 32
HomeWorks RF Keypads or Tabletop RF
Keypads.
• A maximum of 16 RF processors may be
connected together in a system to support a total of 1024 RF dimmers/switches and 512 RF keypads.
Environment
Ambient operating temperature: 0-40°C,
32-104°F, 0-90% humidity, non-condensing. Indoor use only.
Warranty
• 8 Year Limited Warranty.
FCC Information
MOUNTING
in accordance with IEC 6100-4-2.
Mounting Screw
Note: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15 of
the FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one
or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the seperation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Changes or modifications not expressly approved by
Lutron Electronics Co. could void the user’s authority to operate
this equipment.
Industry Canada Information
The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met.
Optional Mounting Screw
®
JOB NAME:
JOB NUMBER:
SPECIFICATION SUBMITTAL
MODEL NUMBERS:
Page
P
HomeWorks InteractiveTM
PROCESSORS
RF Processor
048-020 3a 11.05.02
DIMENSIONS
Side View
Front View
(port cover removed)
6.7"
(170mm)
1.77"
(45mm)
8"
(203mm)
0.70"
(18mm)
6.16"
(157mm)
5.77"
(147mm)
11.54"
(293mm)
1.25"
(32mm)
TO U C H PA D
Home Key
Returns user to the
Home Screen
Power LED
LCD Screen
OK
®
JOB NAME:
JOB NUMBER:
SPECIFICATION SUBMITTAL
MODEL NUMBERS:
Menu Navigation Keys
Allows user to navigate
through the various
screens and menus on
the LCD Screen
Page
P
HomeWorks InteractiveTM
PROCESSORS
RF Processor
048-020 4a 11.05.02
INTER-PROCESSOR WIRING
Wired
Processor
RF Processor
RF Processor
OK
OK
88
TX
1 2 3 4
TX
RX
BUS
1 2 3 4
G1 V1 G2 V2
RX
BUS
1 2 3 4
TX
TX
RX
BUS
1 2 3 4
G3 V3 G4 V4
1 2
LT-1 Link
Terminator
Pin 1 - 1 No. 18 AWG (1.0mm2)
Pins 3 & 4 - 1 pair No. 22-18 AWG (0.5 - 1.0mm2)
twisted/shielded for data
Pin 2 is not connected
LT-1 Link
Terminator
Wiring Detail
LT-1 Link
Terminator
Wiring Detail
WIRING
1 2 3 4
TX
3 4
1 2 3 4
TX
RX
BUS
1 2 3 4
G5 V5 G6 V6
RX
BUS
PROCESSOR
LINK
Link 7
RS-232 Link
LT-1 Link
Terminator
1 2 3 4
1 2 3 4
RX
BUS
1 2 3 4
RX
1 2 3 4
TX
PROCESSOR
LINK
P OW E R S U P P LY C O N N E C T I O N
Processor wiring must be in a daisy-chain
configuration. The total length of wire on
the Inter-Processor Link may be up to
1,000 ft. (305m). For wire runs exceeding
50 ft. (15m) in length, LT-1 Link
Terminators must be used on the processors at both ends of the wire run. Up to 16
Processors (RF or Wired) may be connected
together.
OK
WIRE TYPE
Two pair [one pair #18 AWG (1.0mm2),
one pair #22-18 AWG (0.5-1.0mm2) twisted
shielded] Class 2/PELV. Lutron wire, model
# GRX-CBL-346S-500, may be used.
®
JOB NAME:
JOB NUMBER:
SPECIFICATION SUBMITTAL
MODEL NUMBERS:
Page
P
HomeWorks InteractiveTM
PROCESSORS
RF Processor
048-020 5a 11.05.02
Home A: 2500 sq. ft. (232m ) or less - all RF devices within 30' (9m) of RF Processor
SY S T E M C O M M U N I C AT I O N N OT E S
• RF Dimmers and Keypads must be located
within 30 feet (9.14m) of an RF Signal
Repeater or an RF Processor. Multiple
repeaters may be necessary to provide
adequate coverage.
• RF Dimmers cannot be controlled and RF
Keypads will not function until they are
addressed and programmed. See the
HomeWorks Interactive Programming
Utility online help.
• RF Processors and RF Signal Repeaters
provide RF coverage for an area of
approximately 2500 sq. ft. (m2). One (1)
RF Processor with four (4) RF Signal
Repeaters will cover an area of approximately 12,500 sq. ft. (m2). Additional RF
Processors with associated RF Signal
Repeaters may be added to provide larger
coverage areas.
RF Tabletop
Keypad
RF Dimmer
RF Keypad
* Start
P/N 292
292-153
153
30 Feet (9m) maximum
RF Processor
Home B: 2500 sq. ft. (232m2) or greater - some RF devices more than 30' (9m) from RF Processor
RF Tabletop
Keypad
30 Feet (9m) maximum
RF Signal Repeater
RF Dimmer
RF Keypad
RF Processor
60 Feet (18m)
maximum
between RF
Processors and
Repeaters, or
between
Repeaters
P/N 292
292-153
153
30 Feet (9m) maximum
®
JOB NAME:
JOB NUMBER:
SPECIFICATION SUBMITTAL
MODEL NUMBERS:
Page

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2002:11:14 12:47:06-05:00
Modify Date                     : 2002:11:14 12:47:06-05:00
Page Count                      : 5
Creation Date                   : 2002:11:14 17:47:06Z
Mod Date                        : 2002:11:14 17:47:06Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : rlau
Metadata Date                   : 2002:11:14 17:47:06Z
Creator                         : rlau
Title                           : RF proc spec.qxd
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JPZ0023

Navigation menu