Lutron Electronics 0096 Relay Module User Manual Manual 1

Lutron Electronics Company Inc Relay Module Manual 1

Contents

Manual 1

Download: Lutron Electronics 0096 Relay Module User Manual Manual 1
Mirror Download [FCC.gov]Lutron Electronics 0096 Relay Module User Manual Manual 1
Document ID2089138
Application IDThq+2LfSrAmwolaUKA8FYA==
Document DescriptionManual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize40.19kB (502435 bits)
Date Submitted2013-10-01 00:00:00
Date Available2013-10-01 00:00:00
Creation Date2013-05-30 11:16:29
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2013-05-30 11:16:32
Document TitleManual 1
Document CreatorAdobe InDesign CS6 (Windows)

Technical Assistance | 1.800.523.9466 USA, Canada, and the Caribbean | +44.(0)20.7702.0657 Europe | +1.610.282.3800 Others | www.lutron.com
RF CCO Module | Installation
041424
Rev. A
05/2013
LMJ-CCO1-24-B
LMK-CCO1-24-B
LMN-CCO1-24-B
LMM-CCO1-24-B
LMQ-CCO1-24-B
24 V~  45 mA
24 V-  35 mA
NECR Class 2
24 V~  45 mA
24 V-  35 mA
SELV
RF CCO Module Operation
For System Setup Guide and tools
visit www.lutron.com
English
WARNING
CCO
Status
LED
CCO Toggle
Advanced
Operations
Contact
Closure
Output
(CCO)
Important Notes: Please read before installing.
• F
 or installation by a qualified electrician in accordance
with all local and national electrical codes.
• Note: Use copper conductors only.
• Check to see that the device type and rating is suitable
for the application.
• DO NOT install if product has any visible damage.
• If moisture or condensation is evident, allow the product
to dry completely before installation.
• Operate between 32 °F to 131 °F (0 °C to 55 °C).
• 0% to 90% humidity, non-condensing.
• For indoor use only.
• 24 V~  or 24 V- supply and load shall be protected
via an approved power source in accordance with IEC/
EN61558-2 (SELV supply).
Reset Factory Defaults
RF CCO Module
Installation:
LMJ-, LMM-, LMQ- models
When installing a RF CCO Module,
wire the module as shown.
Note: RF CCO Module may also be
mounted on or inside a junction box.
If installing unit inside a junction box please
see Application Note #423.
For more information:
www.lutron.com
24 V~  or 24 VWire Nut
(2 Supplied)
Note: CCO Module supply
wires can be connected in
any polarity.
COM
Mounting screw
(2 Supplied)
(Common)
NO
To CCO-controlled device.
(Normally Open)
NC
(Normally Closed)
Note: When wiring CCO output,
use 20 AWG to 16 AWG
(0.5 mm2 to 1.5 mm2) solid or
stranded wire.
Shock Hazard. May result in
serious injury or death.
Turn off power at circuit breaker
before installing the unit.
FCC Information: (LMJ- model only)
This device complies with part 15 of the FCC Rules and
Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference, including
interference that may cause undesired operation.
Modifications not expressly approved by Lutron Electronics Co.,
Inc. could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Installation:
LMK- and LMN- models
The RF CCO Module should be
installed using the mounting tabs
on the enclosure (screws not
provided). The RF CCO Module
can be installed in a junction
box or marshalling box (optional)
using the conduit nut (provided)
or with mounting screws (not
provided). Please consult local and
national electric codes for proper
installation.
are registered trademarks of Lutron Electronics
Lutron and
Co., Inc.
©2013 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc. | 7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Triple-tap the Advanced Operations
(“ADV”) button, on the RF CCO
Module and hold until the LED
begins to flash slowly.
Within 3 seconds of flashing,
release and triple-tap the button
again and the LED will flash
rapidly indicating that the unit has
been reset to factory defaults.
Note:	
Any associations or programming
previously set up with the unit will
be lost and will need to be
re-programmed.
Troubleshooting
CCOcontrolled
device does
not respond
to Wireless
Transmitter(s).
• Ensure power to the RF
CCO Module is properly
applied.
• Ensure the CCOcontrolled device has
been properly wired to
the RF CCO Module.
• Ensure RF CCO module
has been activated in
the system.
• Ensure that the Wireless
Transmitter battery is
installed correctly.
RF CCO
Module does
not respond
to a keypad,
wireless
controller or
sensor.
• Improper programming.
Program from system
programming software.
• Out of RF Range.
Reposition to be within
30 ft (9 m) of an RF
signal repeater.
• Already at current level.
The RF CCO Module
has already responded
to a command, or is
already at the requested
setting.
• Wireless controller or
sensor batteries low or
installed incorrectly.
Replace or install
batteries properly.
• RF interference.
Do not run RF CCO
Module wires with
other power wires or
communication wires
(e.g., networking, audio,
or video signals).
24 V~  or 24 V21 mm
knockout
opening
Note: CCO Module supply
wires can be connected in
any polarity.
COM
Conduit Nut
(Common)
NO
To CCO-controlled device.
(Normally Open)
NC
(Normally Closed)
1 3
10 mm
Note: When wiring CCO output,
use 0.5 mm2 to 1.5 mm2 (20 AWG
to 16 AWG) solid or stranded wire.
Wiring a Lever Operated Connector (shown)
When wiring lever operated connectors (2 supplied)
please use 2.5 mm2 to 4.0 mm2 (14 AWG to 12 AWG)
diameter solid or stranded copper wire.
For LMN-CCO-24-B use supplied Twist-on wire
connectors. (2 supplied)
Warranty:
For warranty information, please visit
www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
www.lutron.com/TechnicalDocumentLibrary/Intl_Warranty.pdf
Note: In some instances it may be
necessary to reset the RF CCO
Module back to factory default
settings.
RF CCO Module Placement
RF CCO Modules must be located within 30 ft (9 m) of an RF signal repeater. RF CCO modules cannot be
controlled by the system until they are programmed using the system programming software.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2013:05:30 11:16:29-04:00
Metadata Date                   : 2013:05:30 11:16:32-04:00
Modify Date                     : 2013:05:30 11:16:32-04:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:40a79959-7995-4db1-904e-101067796b9a
Original Document ID            : xmp.did:24C4857599ADE211A26EB33092D268A3
Document ID                     : xmp.id:A96139E73BC9E211B1C9D0693B3803F1
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:52E0ABDB3BC9E211B1C9D0693B3803F1
Derived From Document ID        : xmp.did:D884AAB086BDE211AD05C3C3D1083E7D
Derived From Original Document ID: xmp.did:24C4857599ADE211A26EB33092D268A3
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2013:05:30 11:16:29-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 1
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JPZ0096

Navigation menu