Mertik Maxitrol and KG B6RHAS Control Unit For GV60/Symax System User Manual Users manual Part 2 of 3

Mertik Maxitrol GmbH & Co. KG Control Unit For GV60/Symax System Users manual Part 2 of 3

Contents

Users manual Part 2 of 3

15 / 29ENGLISHINSTALLATION AND OPERATING INSTRUCTIONS   FOR OEM USE ONLY© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.DRAFT 21/11/2018MODES OF OPERATION1  2ONAMPMOFF Thermostatic Mode The room temperature is measured and compared to the set temperature. The ame  height  is  then  automatically  ad-justed to achieve the set temperature.1  2ONAMPMOFF  Program Mode PROGRAMS 1 and 2, each can be pro-grammed to go ON and OFF at specic times at a set temperature. AM   Eco ModeFlame height modulates between high and low. If the room temperature is low-er  than  the  set  temperature,  the  ame height stays on high for a longer period of time. If the room temperature is high-er  than  the  set  temperature,  the  ame height stays on low for a longer period of time. One cycle lasts approx. 20 min.THERMOSTATIC MODE1  2ONAMPMOFFON: Press   button.   displayed, preset tem-perature displayed briey, and then room temperature displayed.OFF: 1.   Press   button.2.   Press   or   button to enter Manual Mode.3.   Press   button to enter Program Mode.4.   Press   button to enter Eco Mode.1  2ONAMPMOFFSETTING: 1.   Press   button and hold until   dis-played, temperature ashes.2.  To adjust set temperature press   or  button.3. To conrm press   button or wait.PROGRAM MODE1  2ONAMPMOFFON: Press   button.  ,   or ,   or   displayed. 1  2ONAMPMOFFOFF: 1.   Press   or   or   button to enter Manual Mode.2.   Press   button to enter Thermostatic Mode.NOTE:  The set temperature for Thermostatic Mode is the tem-perature for the ON time in Program Mode. Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode.Default settings: ON  TIME  (Thermostatic)  TEMPERATURE:  70 °F / 21 °C OFF TIME TEMPERATURE: “ ” (pilot ame only)1  2ONAMPMOFFTEMPERATURE SETTING: 1.   Press   button and hold until   ashes.  and set temperature (set-ting in Thermostatic Mode) displayed. 2.  To continue press   button or wait.  ,   displayed, temperature ash-es.3.  Select OFF temperature by pressing the   or   button.4.   To conrm press   button. NOTE:  The ON (Thermostatic) and OFF set temperatures are the same for each day.1  2ONAMPMOFFDAY SETTING: 5.    ashes. Press   or   button to choose between  ,  ,   ,  ,  ,   ,  ,   ,  .6.  To conrm press   button.
16 / 29INSTALLATION AND OPERATING INSTRUCTIONS  FOR OEM USE ONLY© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.DRAFT 21/11/2018 selected 1  2ONAMPMOFFON TIME SETTING (PROGRAM 1):   7.   ,  ,   displayed,   is displayed shortly, and hour ashes.   8. To select hour press   or   button.  9.  To  conrm  press   button.  ,  ,  displayed,   displayed shortly, and minutes ash. 10.  To select minutes press   or   but-ton.11. To conrm press   button.  OFF TIME SETTING (PROGRAM 1):1  2ONAMPMOFF12.   ,  ,  displayed,   is displayed shortly, and hour ashes.13.  To select hour, press   or   button.14.  To  conrm  press   button.  ,  ,  displayed,   displayed short-ly, and minutes ash.15.  To select minutes press   or   but-ton.16. To conrm press   button.NOTE:  Either continue to PROGRAM 2 and set on and off times or stop programming at this point, and PROGRAM 2 re-mains deactivated.NOTE:  PROGRAM 1 and 2 use the same ON (Thermostatic) and OFF temperatures for  ,   and Daily Timer (  ,  ,  ,  ,   ,   ,   ). Once a new ON (Thermostatic)  and / or  OFF temperature has been set, that temperature becomes the new default setting.NOTE:   If  ,   or Daily Timer are programmed for PRO-GRAM 1 and PROGRAM 2 ON and OFF times, these become the new default times. The batteries must be re-moved to clear the PROGRAM 1 and PROGRAM 2 ON and OFF times and temperatures. or Daily Timer (  ,  ,  ,   ,   ,   ,   ) selected▪   Set ON time and OFF time using same procedure as “   se-lected” (above).▪  : Set ON time and OFF time for both Saturday and Sunday.▪  Daily Timer: Unique ON and OFF times may be set for a single day of the week, for multiple days of the week, or for every day of the week. ▪   Wait to nish setting. AUXILIARY FEATURE (2ND BURNER FEATURE)The latching solenoid valve will open automatically after ignition or after switching the system off, so that the maximum ow of gas is supplied to both burners assisting with the ignition pro-cess. After pressing the AUX-button the motor will turn 7 sec-onds in the ON direction until the max. position is reached.1  2ONAMPMOFFON: To switch a burner ON, press the   but-ton.   displayed. OFF:   To switch the burner OFF, press the  button.   disappears.NOTE:  The latching solenoid valve cannot operate manually. If the receiver battery runs down it will remain in the last operating position. ECO MODEAMON: Press   button to enter Eco Mode. displayed.OFF:  Press   button.   disappears.MYFIRE APPNOTICEBefore the app can be used, the myre Wi-Fi Box must be wired and plugged into mains power according to myre app setup diagram (see gure 30, page 29), and the app setup must be completed (see myre app setup, page 24).1  2ONAMPMOFFIf Thermostatic, Program or Eco Mode is activated, the corresponding icon and “” is displayed on the handset.The modes can be operated according to the descriptions on previous pages.NOTE:  In Manual Mode “” is NOT displayed on the handset.
17 / 29ENGLISHINSTALLATION AND OPERATING INSTRUCTIONS   FOR OEM USE ONLY© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.DRAFT 21/11/2018CHILD PROOF1  2ONAMPMOFFON: To activate press   and   buttons simultaneously.   displayed and the handset is rendered inoperable, except for the OFF function.OFF: To deactivate press   and   buttons simultaneously.   disappears.SETTING FAHRENHEIT OR CELSIUS1  2ONAMPMOFFTo change between °C and °F, press   and   buttons simultaneously.NOTE:  Choosing °F results in a 12 hour clock. Choosing °C results in a 24 hour clock.SETTING THE TIMEAMPM1  2ONOFF1.   Press   and   buttons simultane-ously. Day ashes.2.  Press   or   button to select a num-ber to correspond with the day of the week  (e. g.    = Monday,   = Tuesday,  = Wed nesday,    = Thursday,   =  F r i -day,    = Sat urday,   = Sunday). 3.   Press   and   buttons simultane-ously. Hour ashes.4. To select hour press   or   button.5.   Press   and   buttons simultane-ously. Minutes ash.        6.  To select minutes press   or   but-ton.        7.  To  conrm  press   and   buttons simultaneously or wait.10-SYMBOL OPERATIONFigure 22: 10-symbol DisplayLightFanProgram ModeTemperatureTimeAuxiliary Feature (2nd Burner Feature)Countdown TimerBattery StatusSignal Indicator Child ProofEco ModeThermostatic Mode1  2ONAMPMOFFFahrenheit or Celsius
18 / 29INSTALLATION AND OPERATING INSTRUCTIONS  FOR OEM USE ONLY© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.DRAFT 21/11/2018MANUAL MODE (HANDSET)NOTICEBEFORE OPERATING1.  Make sure MANUAL knob on the GV60 valve is in the ON, full counterclockwise   position. 2.  Place the ON / OFF switch (if equipped) in the I (ON) position.TO TURN ON FIRE When pilot ignition is conrmed, motor turns automatically to maximum ame height.1  2ONAMPMOFF▪  Press   button (One Button Ignition) or   and   button simultaneously (Two Button Ignition) until two short beeps and a blinking series of lines conrms  the  start  sequence  has  be-gun; release button(s).▪  Main  gas  ows  once  pilot  ignition  is conrmed.▪  Handset automatically goes into Man-ual Mode after main burner ignition.If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions “TURN OFF GAS TO APPLIANCE” (see page 9).STANDBY MODE (PILOT FLAME)Handset▪  Press and hold  button to set appliance to pilot ame.TO TURN OFF FIRE1  2ONAMPMOFFHandset▪  Press  button to turn off.NOTE:  A new ignition is possible after the OFF icon stops ashing.FLAME HEIGHT ADJUSTMENT1  2ONAMPMOFFHandset▪   To  increase  ame  height  press  and hold   button.▪  To decrease ame height or to set ap-pliance to pilot  ame, press and  hold  button.DESIGNATED LOW FIRE AND HIGH FIRENOTE:  Backlight must be on for high re and low re double-click operation.AM▪   To go to low  re, double-click   but-ton.   is displayed.NOTE:  Flame goes to high re rst be-fore going to low re.AM▪   To go to high re, double-click   but-ton.   is displayed.If the appliance will not operate, follow the instructions “TURN OFF GAS TO APPLIANCE” (see page 9).COUNTDOWN TIMER1  2ONAMPMOFFON / SETTING: 1.  Press and hold   button until   dis-played, and hour ashes. 2.  To select hour press   or   button.3.  To conrm press   button. Minutes ash.4.   To select minutes press   or   button.5.  To conrm press   button or wait.OFF:  Press   button,   and Countdown Time disappear.NOTE:  At end of Countdown Time period, the re shuts off. The Countdown Timer only works in Manual, Thermostatic, and Eco Modes. Maximum Countdown Time is 9 hours and 50 minutes.
19 / 29ENGLISHINSTALLATION AND OPERATING INSTRUCTIONS   FOR OEM USE ONLY© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.DRAFT 21/11/2018MODES OF OPERATION1  2ONAMPMOFF   Thermostatic Mode The room temperature is measured and compared to the set temperature. The ame  height  is  then  automatically  ad-justed to achieve the set temperature.1  2ONAMPMOFF  Program Mode PROGRAM 1 and 2, each can be pro-grammed to go ON and OFF at specic times at a set temperature. AM Eco ModeFlame height modulates between high and low. If the room temperature is low-er  than  the  set  temperature,  the  ame height stays on high for a longer period of time. If the room temperature is high-er  than  the  set  temperature,  the  ame height stays on low for a longer period of time. One cycle lasts approx. 20 min.THERMOSTATIC MODE1  2ONAMPMOFFON: Press   button.   displayed, preset tem-perature displayed briey, and then room temperature displayed.OFF: 1.   Press   button.2.   Press   or   button to enter Manual Mode.3.   Press   button to enter Program Mode.4.   Press   button to enter Eco Mode.1  2ONAMPMOFFSETTING: 1.   Press   button and hold until   dis-played, temperature ashes.2.  To adjust set temperature press   or  button.3. To conrm press   button or wait.PROGRAM MODE1  2ONAMPMOFFON: Press   button.  ,   or ,   or  displayed. 1  2ONAMPMOFFOFF: 1.   Press   or   or   button to enter Manual Mode.2.   Press   button to enter Thermostatic Mode.3.   Press   button to enter Eco Mode.NOTE:  The set temperature for Thermostatic Mode is the tem-perature for the ON time in Program Mode. Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode.Default settings: ON  TIME  (Thermostatic)  TEMPERATURE:  70 °F / 21 °C OFF TIME TEMPERATURE: “ ” (pilot ame only)1  2ONAMPMOFFTEMPERATURE SETTING: 1.   Press   button and hold until   ashes.  and set temperature (set-ting in Thermostatic Mode) displayed. 2.  To continue press   button or wait.  ,   displayed, temperature ash-es.3.   Select  OFF temperature by pressing the   or   button.4.   To conrm press   button. NOTE:   The  ON (Thermostatic) and OFF set temperatures are the same for each day.1  2ONAMPMOFFDAY SETTING: 5.    ashes. Press   or   button to choose between  ,  ,   ,  ,  ,   ,  ,   ,  .6.  To conrm press   button.
20 / 29INSTALLATION AND OPERATING INSTRUCTIONS  FOR OEM USE ONLY© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.DRAFT 21/11/2018 SELECTED 1  2ONAMPMOFFON TIME SETTING (PROGRAM 1):   7.   ,  ,   displayed,   is displayed shortly, and hour ashes.   8. To select hour press   or   button.  9.  To  conrm  press   button.  ,  ,  displayed,   displayed shortly, and minutes ash. 10.  To select minutes press   or   but-ton.11. To conrm press   button.  OFF TIME SETTING (PROGRAM 1):1  2ONAMPMOFF12.   ,  ,  displayed,   is displayed shortly, and hour ashes.13.  To select hour, press   or   button.14.  To  conrm  press   button.  ,  ,  displayed,   displayed short-ly, and minutes ash.15.  To select minutes press   or   but-ton.16. To conrm press   button.NOTE:  Either continue to PROGRAM 2 and set on and off times or stop programming at this point, and PROGRAM 2 re-mains deactivated.NOTE:  PROGRAM 1 and 2 use the same on (Thermostatic) and off temperatures for  ,   and Daily Timer (  ,  ,  ,   ,   ,  ,   ). Once a new on (Thermostatic) and / or off tempera-ture has been set, that temperature becomes the new default setting.NOTE:   If  ,   or Daily Timer are programmed for PRO-GRAM 1 and PROGRAM 2 on and off times, these be-come the new default times. The batteries must be re-moved to clear the PROGRAM 1 and PROGRAM 2 on and off times and temperatures. or Daily Timer (  ,  ,  ,   ,   ,   ,   ) selected▪   Set  on  time  and  off  time  using  same  procedure  as  “   se-lected” (above).▪  : Set on time and off time for both Saturday and Sunday.▪  Daily Timer: Unique  on and off times may  be  set for a single day of the week, for multiple days of the week, or for every day of the week. ▪   Wait to nish setting. AUXILIARY FEATURE (2ND BURNER FEATURE)The latching solenoid valve will open automatically after ignition or after switching the system off, so that the maximum ow of gas is supplied to both burners assisting with the ignition pro-cess. After pressing the AUX-button the motor will turn 7 sec-onds in the ON direction until the max. position is reached.1  2ONAMPMOFFON:To switch a burner on, press the   but-ton.   displayed. OFF:  To switch the burner off, press the  button.   disappears.NOTE:  The latching solenoid valve cannot operate manually. If the receiver battery runs down it will remain in the last operating position. ECO MODEAMON: Press   button to enter Eco Mode.   displayed.OFF:  Press   button.   disappears.CIRCULATING FAN OPERATIONAMCirculating fan has 4 speed levels from low (1 bar) to high (4 bars).SETTING:  1.   Press   button and hold until   ashes.2.   Press   button to increase fan speed and   button to decrease fan speed.3.  To conrm setting either press   but-ton or wait (  displayed).OFF:    Press   button until all 4 speed level bars disappear.NOTE:  SETTING only. If the fan was not switched off after last use, it starts automatically 4 minutes after ignition at max-imum speed and goes to the last set level after 10 sec-onds. The fan stops 10 minutes after the gas is OFF or at pilot.
21 / 29ENGLISHINSTALLATION AND OPERATING INSTRUCTIONS   FOR OEM USE ONLY© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.DRAFT 21/11/2018AMON: Press   button (   displayed). Light is on at preset level.OFF: Press   button (   disappears).  SETTING:  1.   Press   button and hold until   ash-es.2.  To adjust light between 20…100 % press   or   button.  3.  To conrm setting either press   but-ton or wait (   displayed).NOTE:  The Light works independently of the pilot ame. If you want the light on but no ame, press   button.MYFIRE APPNOTICEBefore the app can be used, the myre Wi-Fi Box must be wired and plugged into mains power according to myre app setup diagram (see gure 30, page 29), and the app setup must be completed (see myre app setup, page 24).1  2ONAMPMOFFIf Thermostatic, Program or Eco Mode is activated, the corresponding icon and “” is displayed on the handset.The modes can be operated according to the descriptions on previous pages.NOTE:  In Manual Mode “” is NOT displayed on the handset.LIGHT / DIMMER  OPERATION
22 / 29INSTALLATION AND OPERATING INSTRUCTIONS  FOR OEM USE ONLY© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.DRAFT 21/11/2018The Puck is a smart control that works in conjunction with the GV60 / Symax system. Its basic functions include turning the re on and off and turning the ame height up and down.The Puck is equipped with temperature sensing that allows the use of the popular myre app. ON / OFFUp / HIDown /LO Figure 23: 3-button layout TECHNICAL DATAAMBIENT TEMPERATURE RANGE  CSA:  The Puck: 32 °F to 131 °F  CE:  The Puck: 0 °C to 55 °C   RADIO FREQUENCY   CSA:    918 MHz for U.S. and for Canada (The Puck, receiver)  CE:  868 MHz for Europe (The Puck, receiver)  (see radio frequency information on page 4.) POWER SUPPLY  Handset:  2 x 1.5 V “AAA” (quality alkaline recommended)        NOTICEWiring of valve and receiver must be completed before starting ignition. Failure to do so could damage the electronics.NOTICEThe handsets and receivers are not interchangeable with previous electronics.To avoid damaging the electronics, do NOT use metal tools to remove the batteries from the handset / receiver. ▪  Without using a mains adapter, battery replacement is recom-mended at the beginning of each heating season.▪  Old or dead batteries should be removed immediately. If left in the unit the batteries can overheat, leak, and / or explode.▪  Do NOT expose batteries (including during storage) to direct sunlight, excessive heat, re, moisture, or severe impact. Each of these conditions can cause the batteries to overheat, leak, and / or  explode. ▪  Batteries must be kept within their recommended temperature limits (ambient battery temperature range: 32 °F to 131 °F / 0 °C  to  55 °C).▪  New and old batteries and different brands of batteries should not be used together. Mixing of various batteries can cause the batteries to overheat, leak, and / or explode.THE PUCK HANDSETSYNCHRONIZATION RECEIVER / THE PUCK HANDSETNOTICESee page 7 for more information about synchronization between receiver and The Puck handset.MODES OF OPERATIONWhen pilot ignition is conrmed, motor turns automatically to maximum ame height.TURN FIRE ON  AND OFF▪  Press and hold the   button until two short  beeps  conrms  the  start  se-quence has begun; release button.▪  Main  gas  ows  once  pilot  ignition  is conrmed.▪  Press  and  hold  the   button to turn OFF.If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions “TURN OFF GAS TO APPLIANCE” (see page 9).  STANDBY MODE (PILOT FLAME)▪  Press and hold the "–" button to set appliance to pilot ameFLAME HEIGHT ADJUSTMENT▪   To  increase  ame  height  press  and hold "+" button.▪  To decrease ame height or to set ap-pliance to pilot  ame,  press and  hold "–" button.DESIGNATED LOW FIRE AND HIGH FIRE▪   To go to hi re, double-click "+" button.▪   To go to low re, double-click "–" button. NOTE:  Flame goes to high re rst be-fore going to low re.If the appliance will not operate, follow the instructions “TURN OFF GAS TO APPLIANCE” (see page 9).
23 / 29ENGLISHINSTALLATION AND OPERATING INSTRUCTIONS   FOR OEM USE ONLY© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.DRAFT 21/11/2018MYFIRE WI-FI BOX (B6R-W2…)The new Wi-Fi Box has a faster processing speed, variable power supply between 5 and 24 volts, two RGB outlets, identical con-nectors on both ends of the cable, and the Wi-Fi Box itself has a much smaller footprint.TECHNICAL DATAAMBIENT TEMPERATURE RANGE  CSA:  myre Wi-Fi Box: 32 °F to 176 °F  CE:  myre Wi-Fi Box: 0 °C to 80 °C   RADIO FREQUENCY  CSA + CE: 2.4 GHz  (see radio frequency information on page 4.) POWER SUPPLY   6 V connection to the receiver which is connected to an AC mains adapter.WIRELESS COMMUNICATION  ▪   WPA2 authentication  ▪   AES 256-bit encryption security  ▪   Compatible with IEEE 802.11 b/g/nPOWER CONSUMPTION  CSA + CE: Nominal:   max. 0.5 W  CSA + CE: Standby:   max. 5 mALED RGB CONTROL OUTPUT  CSA + CE:    Phoenix, 3 pol, MC 1.5 / 3-ST-3.5,        5 VDC  -  24 VDC / 5 ALED RGB EXTERNAL POWER INPUT  CSA + CE:    Phoenix, 2 pol, MC 1.5 / 2-ST-3,        5 VDC  -  24 VDC / 5 AMODES OF OPERATIONThe myre Wi-Fi Box communicates with a home network (Wi-Fi Router) over a wireless signal.  1.  The myre Wi-Fi Box must be wired to the receiver according to the myre app setup diagram (see gure 30, page 29) 2.  Connect receiver to mains power. The myre Wi-Fi Box start with the Access Point Mode (green/blue LED blinking). Go to “myre app setup”…MINIMUM REQUIREMENT FOR WI-FI ROUTER▪   IEEE 802.11n/g/b compatibility▪   WPA2 encryption ▪  Radio frequency: 2.4 GHz band▪    Wireless  auto  channel:  Automated  search  for  WLAN  radio channel free of interference ▪    User Datagram Protocol (UDP) support▪    multicast DNS (mDNS) for Kwik Connect processMINIMUM REQUIREMENT SMART DEVICE:▪  iOS 8.0 or Android 4.2Reset button (Use paper clip to push button)Receiver LED 1RGBPower Input Receiver cableRGB 1 RGB 2Figure 24: myre Wi-Fi Box (B6R-W2…) LED INDICATION ON MYFIRE WI-FI BOX (see gure 24, page 23)2 RGB LEDsLabel LED StatusReceiver LED 1Green Connected to receiver.Red Not connected to receiver.Off Standby mode is active or no Power supply.WLAN LED 2Green Wi-Fi connection is safe.Blue/Green blinking Access point mode (AP mode) is active.Red Not connected to home network (Wi-Fi Router).Off Standby mode is active or no power supply.RESET STATUS ON MYFIRE WI-FI BOX:Press Reset ButtonLED FunctionPower-On-Reset or 1-sec-ResetWLAN LED 2 ashes red, green and blueIf no network is set, the AP Mode will be activated for 2 hours. When the network isn't set after 2 hours, the Wi-Fi Box will go to Standby Mode.Once a network is set, the Wi-Fi Box will connect directly.7 secs WLAN LED 1 ashes every 500 ms in blueRemoves the Wi-Fi settings and turns on the Access point mode (AP mode) for 2 hours.20 secs WLAN LED 1 ashes every 50 ms in blueErases all Setup Data. The Wi-Fi chip will be set to the last version after the reboot. The AP-Mode will be activated for 2 hours.NOTICE▪  A Symax handset or The Puck must be used to achieve full functionality.▪  If mains power is lost, disconnect the myre Wi-Fi Box from the receiver. This will prevent receiver batteries from being drained quickly.▪  Multiple users on the same Wi-Fi channel may interfere with the data transfer. Press reset button on the myre Wi-Fi Box for 1 second to change current channel (see gure 24, page 23).▪  If no network is congured, the myre Wi-Fi Box will leave the Access Point Mode (AP Mode) after 2 hours.▪  If you have multiple replaces using myre Wi-Fi Boxes, the minimum distance between the myre Wi-Fi Boxes must be 60 cm (2'). A shorter distance may interfere with the data transfer.Do not connect the combination control system to the LED connections of the myre Wi-Fi Box.WLAN LED 2
24 / 29INSTALLATION AND OPERATING INSTRUCTIONS  FOR OEM USE ONLY© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.DRAFT 21/11/2018MYFIRE APP SETUPNOTICEFor myre app setup, you will need your Wi-Fi network SSID and password. For more detailed app setup / operating instructions refer to www.myreapp.comINITIAL SETUP1.  Download  myre  app  from  Apple  App  Store or Google  Play Store.2.  Touch screen to start app setup.3.  Choose language, temperature (°C or °F) and time format (12 or 24 hour).REGISTRATIONNOTE:  You must register before logging in. Registration is one time only.1. Fill in data and accept the “Privacy Policy”.2. Touch “OK” in pop-up notice.3. Touch link to conrm email verication.4.  You will be shown a message that you have successfully reg-istered the myre app.5. Return to app.LOGIN1. Fill in your registration password.2. Accept “Terms and Conditions”.3. Touch the “Login” button.KWIK CONNECTCONNECT SMART DEVICE TO MYFIRE WI-FI BOX1. Touch  the   icon.2.  The Home Wi-Fi Network name your smart device is currently connected to is displayed.3. Type in the password of the displayed Home Wi-Fi Network.4.  Touch "Connect". The myre App starts connecting the myre Wi-Fi Box to the selected Home Wi-Fi Network.COMPLETE MYFIRE APP SETUP1. Type in a name for your replace or select an icon.2. Activate Fan, Light and AUX if installed to your replace.3. Touch "Finish" to complete the setup.The home screen is displayed and the myre app is ready to go.STANDARD SETUPIF KWIK CONNECT IS NOT AVAILABLE, AND YOU HAVE EN-TERED THE CORRECT PASSWORD, USE STANDARD SETUP. 1. Type in the password of the displayed Home Wi-Fi Network.2.  Follow the instructions on the screen and touch the "Standard Setup" button to proceed.3.  Go to your  smart device Wi-Fi settings and select the myre Wi-Fi Box network (myre_WiFi-Box_<number>) you want to connect.4.  Go back to the myre app setup and follow the instructions on the screen. Your selected Wi-Fi Box network name from the smart device Wi-Fi settings.USE RETRY IF PASSWORD IS INCORRECT1. Touch the "Retry" button to repeat the Kwik Connect process.2. Type in the correct password.NOTICETo connect myre Wi-Fi Box to Wi-Fi Router (home network), make sure:▪ Home network is available.▪ Home network name and password are correct.▪ SSID of the Wi-Fi Router is not hidden.▪ Home network signal is in range.▪ Wi-Fi Router supports User Datagram Protocol (UDP).NOTICE▪  After setting up the myre Wi-Fi Box and myre app, the time has to be synchronized in the settings of the myre app.▪  The  active  device  (The  Puck  or  Symax  handset  or  smart device) is the one last used. An exception is if the non-active devise is used to change Light, Fan, or AUX. The non-active device will make the changes, but the active device remains so if it is in Thermostatic, Program, or Eco Mode. If a Prole includes a Thermostatic, Program, or Eco setting it will also cause the active device to remain active.▪  If Thermostatic, Program, or Eco Mode is activated using the app, the corresponding icon and “ ” is displayed on the Symax handset (see gure 25, page 24).▪  During motor movement no information between receiver and transmitter is exchanged. The synchronization follows after motor has stopped. ▪  The  room  temperature  data  is  transferred  by  the  handset during synchronization.Figure 25: App connected (in Thermostatic Mode)It is the responsibility of the OEM to consider the following:▪  The location of the GV60 system components will signicantly effect the radio signal strength.▪  The type of materials (e.g. sheet metal) used in the construction of the gas replace will signicantly effect the radio signal strength.▪  Operate  the  system  with  a  dedicated  mains  power  supply and/or batteries.▪  Do not use near household electrical wiring and/or magnetic elds.▪  Other transmitters using the same signal will negatively affect the radio signal strength.▪  Adjustment  of  the  on-board  antenna  on  the  receiver  can improve signal strength.▪  Do not store or locate the GV60 system components in a hot, cold, or humid environment.NOTICE
25 / 29ENGLISHINSTALLATION AND OPERATING INSTRUCTIONS   FOR OEM USE ONLY© 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.DRAFT 21/11/2018ON-OFFUPDOWNFigure 26BASICPilot BurnerG30-ZP2M-LWall Switch (optional)G6R-ZWSE(N)…ReceiverB6R-R8(9)P… Thermocurrent Cable SWwith  ON / OFF  SwitchG60-ZSKS(L)S…Thermocurrent Cable TCG60-ZKIRS…8 Wire Cable G6R-C…Interrupter BlockG60-ZUS…Mains Adapter (optional)G60-ZMA3Ignition CableG60-ZKIS… RESET ButtonAdditional functionsThe universal receivers B6R-R8(9)P… and B6R-R8(9)PT… can be used to start a power ue con-trol (2pin outlet) or to operate a second burner or a relay (3pin outlet). Together with a module, the receiver controls a circulating fan and a dimmer.The receiver B6R-R8(9)PT… has main burner supervision (2nd thermocouple option). This option is programmed so that it cannot be used without the second thermocouple installed and vice versa.Main BurnerCombination Control GV60…AntennaWIRING DIAGRAMS

Navigation menu