Mertik Maxitrol and KG B6RHAS Control Unit For GV60/Symax System User Manual Users manual Part 2 of 3
Mertik Maxitrol GmbH & Co. KG Control Unit For GV60/Symax System Users manual Part 2 of 3
Contents
- 1. Users manual Part 1 of 3
- 2. Users manual Part 2 of 3
- 3. Users manual Part 3 of 3
Users manual Part 2 of 3
DRAFT 21/11/2018 MODES OF OPERATION AM PM ON OFF 1 2 AM PM ON OFF Thermostatic Mode he room temperature is measured and compared to the set temperature. The flame height is then automatically adjusted to achieve the set temperature. FOR OEM USE ONLY PROGRAM MODE AM PM AM AM PM ON OFF ON OFF OFF: 1. Press or or button to enter Manual Mode. 2. Press button to enter Thermostatic Mode. Default settings: ON TIME (Thermostatic) TEMPERATURE: 70 °F / 21 °C OFF TIME TEMPERATURE: “ ” (pilot flame only) ON OFF AM PM or NOTE: The set temperature for Thermostatic Mode is the temperature for the ON time in Program Mode. Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode. AM PM THERMOSTATIC MODE or , ON OFF 1 2 Eco Mode Flame height modulates between high and low. If the room temperature is lower than the set temperature, the flame height stays on high for a longer period of time. If the room temperature is higher than the set temperature, the flame height stays on low for a longer period of time. One cycle lasts approx. 20 min. 1 2 Program Mode PROGRAMS 1 and 2, each can be programmed to go ON and OFF at specific times at a set temperature. 1 2 ON: Press button. displayed. 1 2 ON: Press button. displayed, preset temperature displayed briefly, and then room temperature displayed. TEMPERATURE SETTING: 1. Press button and hold until flashes. and set temperature (setting in Thermostatic Mode) displayed. 2. To continue press button or wait. displayed, temperature flashes. 3. Select OFF temperature by pressing the or button. 4. To confirm press button. © 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 1 2 OFF: 1. Press button. 2. Press or button to enter Manual Mode. 3. Press button to enter Program Mode. 4. Press button to enter Eco Mode. NOTE: The ON (Thermostatic) and OFF set temperatures are the same for each day. AM PM AM PM ON OFF 1 2 SETTING: 1. Press button and hold until displayed, temperature flashes. 2. To adjust set temperature press or button. 3. To confirm press button or wait. ON OFF 1 2 DAY SETTING: 5. flashes. Press or button to choose between , , , , , , , . 6. To confirm press button. 15 / 29 ENGLISH INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS DRAFT 21/11/2018 AUXILIARY FEATURE (2ND BURNER FEATURE) selected AM PM ON OFF 1 2 FOR OEM USE ONLY ON TIME SETTING (PROGRAM 1): 7. , , displayed, is displayed shortly, and hour flashes. 8. To select hour press or button. 9. To confirm press button. , , displayed, displayed shortly, and minutes flash. 10. To select minutes press or button. 11. To confirm press button. The latching solenoid valve will open automatically after ignition or after switching the system off, so that the maximum flow of gas is supplied to both burners assisting with the ignition process. After pressing the AUX-button the motor will turn 7 seconds in the ON direction until the max. position is reached. AM PM ON OFF AM PM ON OFF 1 2 but- OFF: To switch the burner OFF, press the button. disappears. 1 2 OFF TIME SETTING (PROGRAM 1): 12. , , displayed, is displayed shortly, and hour flashes. 13. To select hour, press or button. 14. To confirm press button. , , displayed, displayed shortly, and minutes flash. 15. To select minutes press or button. 16. To confirm press button. ON: To switch a burner ON, press the ton. displayed. NOTE: The latching solenoid valve cannot operate manually. If the receiver battery runs down it will remain in the last operating position. ECO MODE NOTE: Either continue to PROGRAM 2 and set on and off times or stop programming at this point, and PROGRAM 2 remains deactivated. AM NOTE: PROGRAM 1 and 2 use the same ON (Thermostatic) and OFF temperatures for and Daily Timer ( , , , , , , ). Once a new ON (Thermostatic) and / or OFF temperature has been set, that temperature becomes the new default setting. NOTE: If or Daily Timer are programmed for PROGRAM 1 and PROGRAM 2 ON and OFF times, these become the new default times. The batteries must be removed to clear the PROGRAM 1 and PROGRAM 2 ON and OFF times and temperatures. ON: Press button to enter Eco Mode. displayed. OFF: Press button. disappears. MYFIRE APP NOTICE ▪ Set ON time and OFF time using same procedure as “ selected” (above). ▪ : Set ON time and OFF time for both Saturday and Sunday. ▪D aily Timer: Unique ON and OFF times may be set for a single day of the week, for multiple days of the week, or for every day of the week. ▪ Wait to finish setting. Before the app can be used, the myfire Wi-Fi Box must be wired and plugged into mains power according to myfire app setup diagram (see figure 30, page 29), and the app setup must be completed (see myfire app setup, page 24). AM PM ON OFF 1 2 If Thermostatic, Program or Eco Mode is activated, the corresponding icon and “ ” is displayed on the handset. The modes can be operated according to the descriptions on previous pages. NOTE: In Manual Mode “ ” is NOT displayed on the handset. 16 / 29 © 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. or Daily Timer ( , , , , , , ) selected DRAFT 21/11/2018 INSTALLATION AND OPERATING INSTRUCTIONS FOR OEM USE ONLY 10-SYMBOL OPERATION Child Proof Time Signal Indicator Thermostatic Mode Battery Status AM PM ENGLISH Fan Countdown Timer Fahrenheit or Celsius Program Mode Light ON OFF 1 2 Eco Mode Temperature Auxiliary Feature (2nd Burner Feature) Figure 22: 10-symbol Display SETTING FAHRENHEIT OR CELSIUS AM PM To change between °C and °F, press and buttons simultaneously. NOTE: C hoosing °F results in a 12 hour clock. Choosing °C results in a 24 hour clock. ON OFF 1 2 CHILD PROOF AM PM ON OFF 1 2 ON: To activate press and buttons simultaneously. displayed and the handset is rendered inoperable, except for the OFF function. OFF: To deactivate press and buttons simultaneously. disappears. SETTING THE TIME AM PM ON OFF © 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 1 2 1. Press and buttons simultaneously. Day flashes. 2. Press or button to select a number to correspond with the day of the week (e. g. = Monday, = Tuesday, = Wednesday, = Thursday, = Friday, = Saturday, = Sunday). 3. Press and buttons simultaneously. Hour flashes. 4. To select hour press or button. 5. Press and buttons simultaneously. Minutes flash. 6. To select minutes press or button. 7. To confirm press and buttons simultaneously or wait. 17 / 29 INSTALLATION AND OPERATING INSTRUCTIONS DRAFT 21/11/2018 MANUAL MODE (HANDSET) NOTICE BEFORE OPERATING 1. Make sure MANUAL knob on the GV60 valve is in the ON, full counterclockwise position. 2. Place the ON / OFF switch (if equipped) in the I (ON) position. FOR OEM USE ONLY DESIGNATED LOW FIRE AND HIGH FIRE NOTE: B acklight must be on for high fire and low fire double-click operation. AM ▪ To go to low fire, double-click ton. is displayed. but- NOTE: Flame goes to high fire first before going to low fire. TO TURN ON FIRE When pilot ignition is confirmed, motor turns automatically to maximum flame height. ▪P ress button (One Button Ignition) or and button simultaneously (Two Button Ignition) until two short beeps and a blinking series of lines confirms the start sequence has begun; release button(s). ▪ Main gas flows once pilot ignition is confirmed. ▪ Handset automatically goes into Manual Mode after main burner ignition. ON OFF 1 2 If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions “TURN OFF GAS TO APPLIANCE” (see page 9). STANDBY MODE (PILOT FLAME) Handset ▪ Press and hold AM COUNTDOWN TIMER AM PM TO TURN OFF FIRE AM PM NOTE: A new ignition is possible after the OFF icon stops flashing. ON OFF 1 2 FLAME HEIGHT ADJUSTMENT AM PM ON OFF 1 2 18 / 29 Handset ▪ To increase flame height press and hold button. ▪ To decrease flame height or to set appliance to pilot flame, press and hold button. but- If the appliance will not operate, follow the instructions “TURN OFF GAS TO APPLIANCE” (see page 9). button to set appliance to pilot flame. Handset ▪P ress button to turn off. ▪ To go to high fire, double-click ton. is displayed. ON OFF 1 2 ON / SETTING: 1. Press and hold button until displayed, and hour flashes. 2. To select hour press or button. 3. To confirm press button. Minutes flash. 4. To select minutes press or button. 5. To confirm press button or wait. OFF: Press button, disappear. and Countdown Time NOTE: A t end of Countdown Time period, the fire shuts off. The Countdown Timer only works in Manual, Thermostatic, and Eco Modes. Maximum Countdown Time is 9 hours and 50 minutes. © 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. AM PM DRAFT 21/11/2018 MODES OF OPERATION AM PM ON OFF 1 2 AM PM ON OFF Thermostatic Mode he room temperature is measured and compared to the set temperature. The flame height is then automatically adjusted to achieve the set temperature. FOR OEM USE ONLY PROGRAM MODE AM PM AM AM PM ON OFF ON OFF OFF: 1. Press or or button to enter Manual Mode. 2. Press button to enter Thermostatic Mode. 3. Press button to enter Eco Mode. Default settings: ON TIME (Thermostatic) TEMPERATURE: 70 °F / 21 °C OFF TIME TEMPERATURE: “ ” (pilot flame only) ON OFF AM PM or NOTE: The set temperature for Thermostatic Mode is the temperature for the ON time in Program Mode. Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode. AM PM THERMOSTATIC MODE or , ON OFF 1 2 Eco Mode Flame height modulates between high and low. If the room temperature is lower than the set temperature, the flame height stays on high for a longer period of time. If the room temperature is higher than the set temperature, the flame height stays on low for a longer period of time. One cycle lasts approx. 20 min. 1 2 Program Mode ROGRAM 1 and 2, each can be proP grammed to go ON and OFF at specific times at a set temperature. 1 2 ON: Press button. displayed. 1 2 ON: Press button. displayed, preset temperature displayed briefly, and then room temperature displayed. TEMPERATURE SETTING: 1. Press button and hold until flashes. and set temperature (setting in Thermostatic Mode) displayed. 2. To continue press button or wait. displayed, temperature flashes. 3. Select OFF temperature by pressing the or button. 4. To confirm press button. © 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 1 2 OFF: 1. Press button. 2. Press or button to enter Manual Mode. 3. Press button to enter Program Mode. 4. Press button to enter Eco Mode. NOTE: The ON (Thermostatic) and OFF set temperatures are the same for each day. AM PM AM PM ON OFF 1 2 SETTING: 1. Press button and hold until displayed, temperature flashes. 2. To adjust set temperature press or button. 3. To confirm press button or wait. ON OFF 1 2 DAY SETTING: 5. flashes. Press or button to choose between , , , , , , , . 6. To confirm press button. 19 / 29 ENGLISH INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS DRAFT 21/11/2018 AUXILIARY FEATURE (2ND BURNER FEATURE) ON OFF 1 2 ON TIME SETTING (PROGRAM 1): 7. , , displayed, is displayed shortly, and hour flashes. 8. To select hour press or button. 9. To confirm press button. , , displayed, displayed shortly, and minutes flash. 10. To select minutes press or button. 11. To confirm press button. The latching solenoid valve will open automatically after ignition or after switching the system off, so that the maximum flow of gas is supplied to both burners assisting with the ignition process. After pressing the AUX-button the motor will turn 7 seconds in the ON direction until the max. position is reached. AM PM ON OFF AM PM ON OFF 1 2 NOTE: Either continue to PROGRAM 2 and set on and off times or stop programming at this point, and PROGRAM 2 remains deactivated. NOTE: The latching solenoid valve cannot operate manually. If the receiver battery runs down it will remain in the last operating position. ECO MODE AM or Daily Timer ( , , , , , , ) selected ▪ Set on time and off time using same procedure as “ selected” (above). ▪ : Set on time and off time for both Saturday and Sunday. ▪ Daily Timer: Unique on and off times may be set for a single day of the week, for multiple days of the week, or for every day of the week. ▪ Wait to finish setting. ON: Press button to enter Eco Mode. displayed. OFF: Press NOTE: PROGRAM 1 and 2 use the same on (Thermostatic) and off temperatures for and Daily Timer ( , , , , , , ). Once a new on (Thermostatic) and / or off temperature has been set, that temperature becomes the new default setting. NOTE: If or Daily Timer are programmed for PROGRAM 1 and PROGRAM 2 on and off times, these become the new default times. The batteries must be removed to clear the PROGRAM 1 and PROGRAM 2 on and off times and temperatures. but- OFF: To switch the burner off, press the button. disappears. 1 2 OFF TIME SETTING (PROGRAM 1): 12. , , displayed, is displayed shortly, and hour flashes. 13. To select hour, press or button. 14. To confirm press button. , , displayed, displayed shortly, and minutes flash. 15. To select minutes press or button. 16. To confirm press button. ON: To switch a burner on, press the ton. displayed. button. disappears. CIRCULATING FAN OPERATION AM Circulating fan has 4 speed levels from low (1 bar) to high (4 bars). SETTING: 1. Press button and hold until flashes. 2. Press button to increase fan speed and button to decrease fan speed. 3. To confirm setting either press button or wait ( displayed). OFF: Press button until all 4 speed level bars disappear. NOTE: S ETTING only. If the fan was not switched off after last use, it starts automatically 4 minutes after ignition at maximum speed and goes to the last set level after 10 seconds. The fan stops 10 minutes after the gas is OFF or at pilot. 20 / 29 © 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. SELECTED AM PM FOR OEM USE ONLY INSTALLATION AND OPERATING INSTRUCTIONS DRAFT 21/11/2018 FOR OEM USE ONLY LIGHT / DIMMER OPERATION AM ON: Press button ( on at preset level. OFF: Press displayed). Light is button ( disappears). ENGLISH SETTING: 1. Press button and hold until flashes. 2. To adjust light between 20…100 % press or button. 3. To confirm setting either press button or wait ( displayed). NOTE: The Light works independently of the pilot flame. If you want the light on but no flame, press button. MYFIRE APP NOTICE Before the app can be used, the myfire Wi-Fi Box must be wired and plugged into mains power according to myfire app setup diagram (see figure 30, page 29), and the app setup must be completed (see myfire app setup, page 24). AM PM ON OFF 1 2 If Thermostatic, Program or Eco Mode is activated, the corresponding icon and “ ” is displayed on the handset. The modes can be operated according to the descriptions on previous pages. © 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. NOTE: In Manual Mode “ ” is NOT displayed on the handset. 21 / 29 DRAFT 21/11/2018 INSTALLATION AND OPERATING INSTRUCTIONS FOR OEM USE ONLY THE PUCK HANDSET The Puck is a smart control that works in conjunction with the GV60 / Symax system. Its basic functions include turning the fire on and off and turning the flame height up and down. The Puck is equipped with temperature sensing that allows the use of the popular myfire app. ON / OFF Down /LO SYNCHRONIZATION RECEIVER / THE PUCK HANDSET NOTICE See page 7 for more information about synchronization between receiver and The Puck handset. MODES OF OPERATION Up / HI Figure 23: 3-button layout TECHNICAL DATA AMBIENT TEMPERATURE RANGE CSA: The Puck: 32 °F to 131 °F CE: The Puck: 0 °C to 55 °C RADIO FREQUENCY CSA: 918 MHz for U.S. and for Canada (The Puck, receiver) CE: 868 MHz for Europe (The Puck, receiver) (see radio frequency information on page 4.) POWER SUPPLY Handset: 2 x 1.5 V “AAA” (quality alkaline recommended) When pilot ignition is confirmed, motor turns automatically to maximum flame height. TURN FIRE ON AND OFF ▪ Press and hold the button until two short beeps confirms the start sequence has begun; release button. ▪ Main gas flows once pilot ignition is confirmed. ▪ Press and hold the button to turn OFF. If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions “TURN OFF GAS TO APPLIANCE” (see page 9). STANDBY MODE (PILOT FLAME) ▪ Press and hold the "–" button to set appliance to pilot flame NOTICE Wiring of valve and receiver must be completed before starting ignition. Failure to do so could damage the electronics. NOTICE To avoid damaging the electronics, do NOT use metal tools to remove the batteries from the handset / receiver. ▪ Without using a mains adapter, battery replacement is recommended at the beginning of each heating season. ▪ Old or dead batteries should be removed immediately. If left in the unit the batteries can overheat, leak, and / or explode. ▪ Do NOT expose batteries (including during storage) to direct sunlight, excessive heat, fire, moisture, or severe impact. Each of these conditions can cause the batteries to overheat, leak, and / or explode. ▪ Batteries must be kept within their recommended temperature limits (ambient battery temperature range: 32 °F to 131 °F / 0 °C to 55 °C). ▪ New and old batteries and different brands of batteries should not be used together. Mixing of various batteries can cause the batteries to overheat, leak, and / or explode. 22 / 29 FLAME HEIGHT ADJUSTMENT ▪ To increase flame height press and hold "+" button. ▪ To decrease flame height or to set appliance to pilot flame, press and hold "–" button. DESIGNATED LOW FIRE AND HIGH FIRE ▪ To go to hi fire, double-click "+" button. ▪ To go to low fire, double-click "–" button. NOTE: F lame goes to high fire first before going to low fire. If the appliance will not operate, follow the instructions “TURN OFF GAS TO APPLIANCE” (see page 9). © 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. The handsets and receivers are not interchangeable with previous electronics. INSTALLATION AND OPERATING INSTRUCTIONS DRAFT 21/11/2018 FOR OEM USE ONLY MYFIRE WI-FI BOX (B6R-W2…) The new Wi-Fi Box has a faster processing speed, variable power supply between 5 and 24 volts, two RGB outlets, identical connectors on both ends of the cable, and the Wi-Fi Box itself has a much smaller footprint. Receiver WLAN LED 1 LED 2 RGB 1 RGB 2 RGB Power Input Receiver cable AMBIENT TEMPERATURE RANGE CSA: myfire Wi-Fi Box: 32 °F to 176 °F CE: myfire Wi-Fi Box: 0 °C to 80 °C RADIO FREQUENCY CSA + CE: 2.4 GHz (see radio frequency information on page 4.) POWER SUPPLY 6 V connection to the receiver which is connected to an AC mains adapter. WIRELESS COMMUNICATION ▪ WPA2 authentication ▪ AES 256-bit encryption security ▪ Compatible with IEEE 802.11 b/g/n POWER CONSUMPTION CSA + CE: Nominal: max. 0.5 W CSA + CE: Standby: max. 5 mA LED RGB CONTROL OUTPUT CSA + CE: Phoenix, 3 pol, MC 1.5 / 3-ST-3.5, 5 VDC - 24 VDC / 5 A LED RGB EXTERNAL POWER INPUT CSA + CE: Phoenix, 2 pol, MC 1.5 / 2-ST-3, 5 VDC - 24 VDC / 5 A MODES OF OPERATION The myfire Wi-Fi Box communicates with a home network (Wi-Fi Router) over a wireless signal. © 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 1. The myfire Wi-Fi Box must be wired to the receiver according to the myfire app setup diagram (see figure 30, page 29) 2. Connect receiver to mains power. The myfire Wi-Fi Box start with the Access Point Mode (green/blue LED blinking). Go to “myfire app setup”… MINIMUM REQUIREMENT FOR WI-FI ROUTER ▪ IEEE 802.11n/g/b compatibility ▪ WPA2 encryption ▪ Radio frequency: 2.4 GHz band ▪ Wireless auto channel: Automated search for WLAN radio channel free of interference ▪ User Datagram Protocol (UDP) support ▪ multicast DNS (mDNS) for Kwik Connect process MINIMUM REQUIREMENT SMART DEVICE: ▪ iOS 8.0 or Android 4.2 Reset button (Use paper clip to push button) Figure 24: myfire Wi-Fi Box (B6R-W2…) LED INDICATION ON MYFIRE WI-FI BOX (see figure 24, page 23) 2 RGB LEDs Label Receiver LED 1 WLAN LED 2 LED Status Green Connected to receiver. Red Not connected to receiver. Off Standby mode is active or no Power supply. Green Wi-Fi connection is safe. Blue/Green blinking Access point mode (AP mode) is active. Red Not connected to home network (Wi-Fi Router). Off Standby mode is active or no power supply. RESET STATUS ON MYFIRE WI-FI BOX: Press Reset Button LED Function Power-OnReset or 1-sec-Reset WLAN LED 2 flashes red, green and blue If no network is set, the AP Mode will be activated for 2 hours. When the network isn't set after 2 hours, the Wi-Fi Box will go to Standby Mode. Once a network is set, the Wi-Fi Box will connect directly. 7 secs WLAN LED 1 flashes every 500 ms in blue Removes the Wi-Fi settings and turns on the Access point mode (AP mode) for 2 hours. 20 secs WLAN LED 1 flashes every 50 ms in blue Erases all Setup Data. The Wi-Fi chip will be set to the last version after the reboot. The AP-Mode will be activated for 2 hours. NOTICE ▪ A Symax handset or The Puck must be used to achieve full functionality. ▪ If mains power is lost, disconnect the myfire Wi-Fi Box from the receiver. This will prevent receiver batteries from being drained quickly. ▪ Multiple users on the same Wi-Fi channel may interfere with the data transfer. Press reset button on the myfire Wi-Fi Box for 1 second to change current channel (see figure 24, page 23). ▪ If no network is configured, the myfire Wi-Fi Box will leave the Access Point Mode (AP Mode) after 2 hours. ▪ If you have multiple fireplaces using myfire Wi-Fi Boxes, the minimum distance between the myfire Wi-Fi Boxes must be 60 cm (2'). A shorter distance may interfere with the data transfer. Do not connect the combination control system to the LED connections of the myfire Wi-Fi Box. 23 / 29 ENGLISH TECHNICAL DATA INSTALLATION AND OPERATING INSTRUCTIONS DRAFT 21/11/2018 FOR OEM USE ONLY MYFIRE APP SETUP NOTICE For more detailed app setup / operating instructions refer to www.myfireapp.com INITIAL SETUP 1. Download myfire app from Apple App Store or Google Play Store. 2. Touch screen to start app setup. 3. Choose language, temperature (°C or °F) and time format (12 or 24 hour). REGISTRATION NOTE: Y ou must register before logging in. Registration is one time only. 1. Fill in data and accept the “Privacy Policy”. 2. Touch “OK” in pop-up notice. 3. Touch link to confirm email verification. 4. You will be shown a message that you have successfully registered the myfire app. 5. Return to app. LOGIN 1. Fill in your registration password. 2. Accept “Terms and Conditions”. 3. Touch the “Login” button. KWIK CONNECT CONNECT SMART DEVICE TO MYFIRE WI-FI BOX 1. Touch the icon. 2. The Home Wi-Fi Network name your smart device is currently connected to is displayed. 3. Type in the password of the displayed Home Wi-Fi Network. 4. Touch "Connect". The myfire App starts connecting the myfire Wi-Fi Box to the selected Home Wi-Fi Network. COMPLETE MYFIRE APP SETUP 1. Type in a name for your fireplace or select an icon. 2. Activate Fan, Light and AUX if installed to your fireplace. 3. Touch "Finish" to complete the setup. The home screen is displayed and the myfire app is ready to go. STANDARD SETUP IF KWIK CONNECT IS NOT AVAILABLE, AND YOU HAVE ENTERED THE CORRECT PASSWORD, USE STANDARD SETUP. 1. Type in the password of the displayed Home Wi-Fi Network. 2. Follow the instructions on the screen and touch the "Standard Setup" button to proceed. 3. Go to your smart device Wi-Fi settings and select the myfire Wi-Fi Box network (myfire_WiFi-Box_) you want to connect. 4. Go back to the myfire app setup and follow the instructions on the screen. Your selected Wi-Fi Box network name from the smart device Wi-Fi settings. 24 / 29 USE RETRY IF PASSWORD IS INCORRECT 1. Touch the "Retry" button to repeat the Kwik Connect process. 2. Type in the correct password. NOTICE To connect myfire Wi-Fi Box to Wi-Fi Router (home network), make sure: ▪ Home network is available. ▪ Home network name and password are correct. ▪ SSID of the Wi-Fi Router is not hidden. ▪ Home network signal is in range. ▪ Wi-Fi Router supports User Datagram Protocol (UDP). NOTICE ▪ After setting up the myfire Wi-Fi Box and myfire app, the time has to be synchronized in the settings of the myfire app. ▪ The active device (The Puck or Symax handset or smart device) is the one last used. An exception is if the non-active devise is used to change Light, Fan, or AUX. The non-active device will make the changes, but the active device remains so if it is in Thermostatic, Program, or Eco Mode. If a Profile includes a Thermostatic, Program, or Eco setting it will also cause the active device to remain active. ▪ If Thermostatic, Program, or Eco Mode is activated using the app, the corresponding icon and “ ” is displayed on the Symax handset (see figure 25, page 24). ▪ During motor movement no information between receiver and transmitter is exchanged. The synchronization follows after motor has stopped. ▪ The room temperature data is transferred by the handset during synchronization. Figure 25: App connected (in Thermostatic Mode) NOTICE It is the responsibility of the OEM to consider the following: ▪ The location of the GV60 system components will significantly effect the radio signal strength. ▪ The type of materials (e.g. sheet metal) used in the construction of the gas fireplace will significantly effect the radio signal strength. ▪ Operate the system with a dedicated mains power supply and/or batteries. ▪ Do not use near household electrical wiring and/or magnetic fields. ▪ Other transmitters using the same signal will negatively affect the radio signal strength. ▪ Adjustment of the on-board antenna on the receiver can improve signal strength. ▪ Do not store or locate the GV60 system components in a hot, cold, or humid environment. © 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. For myfire app setup, you will need your Wi-Fi network SSID and password. Interrupter Block G60-ZUS… Ignition Cable G60-ZKIS… Pilot Burner G30-ZP2M-L Antenna Receiver B6R-R8(9)P… Combination Control GV60… RESET Button ENGLISH Mains Adapter (optional) G60-ZMA3 Wall Switch (optional) G6R-ZWSE(N)… DOWN ON-OFF UP Thermocurrent Cable TC G60-ZKIRS… Thermocurrent Cable SW with ON / OFF Switch G60-ZSKS(L)S… 8 Wire Cable G6R-C… DRAFT 21/11/2018 The receiver B6R-R8(9)PT… has main burner supervision (2nd thermocouple option). This option is programmed so that it cannot be used without the second thermocouple installed and vice versa. Additional functions The universal receivers B6R-R8(9)P… and B6R-R8(9)PT… can be used to start a power flue control (2pin outlet) or to operate a second burner or a relay (3pin outlet). Together with a module, the receiver controls a circulating fan and a dimmer. Main Burner © 2018 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. INSTALLATION AND OPERATING INSTRUCTIONS FOR OEM USE ONLY WIRING DIAGRAMS BASIC Figure 26 25 / 29
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : © Mertik Maxitrol GmbH & Co. KG Create Date : 2018:11:21 13:19:34+01:00 Modify Date : 2019:01:28 16:28:42+01:00 Sensitivity : Confidential Confidential - Label MSIP Label 289bd 36d-23ac-4bc 9-9c 00-d 421e 181dc 1a Name: Confidential MSIP Label D938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Name: Confidential - Label MSIP Label 289bd 36d-23ac-4bc 9-9c 00-d 421e 181dc 1a Owner: christa.jaeger@csagroup.org MSIP Label D938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Owner: christa.jaeger@csagroup.org MSIP Label 289bd 36d-23ac-4bc 9-9c 00-d 421e 181dc 1a Site Id: e600ad84-320a-43ef-bfa4-8f5d25019bde MSIP Label D938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Parent: 289bd36d-23ac-4bc9-9c00-d421e181dc1a MSIP Label D938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Site Id: e600ad84-320a-43ef-bfa4-8f5d25019bde MSIP Label 289bd 36d-23ac-4bc 9-9c 00-d 421e 181dc 1a Enabled: True MSIP Label 289bd 36d-23ac-4bc 9-9c 00-d 421e 181dc 1a Set Date: 2019-01-28T15:12:27.0397561Z MSIP Label D938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Enabled: True MSIP Label D938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Set Date: 2019-01-28T15:12:27.0397561Z MSIP Label 289bd 36d-23ac-4bc 9-9c 00-d 421e 181dc 1a Application: Microsoft Azure Information Protection MSIP Label D938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Application: Microsoft Azure Information Protection MSIP Label 289bd 36d-23ac-4bc 9-9c 00-d 421e 181dc 1a Extended MSFT Method: Manual MSIP Label D938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Extended MSFT Method: Manual Language : de-DE XMP Toolkit : XMP Core 5.5.0 Instance ID : uuid:6b4059d7-f81d-3646-9c5d-5f4ba1a54eef Original Document ID : adobe:docid:indd:89ae7fdd-b400-11df-931f-97454b1087d1 Document ID : xmp.id:2e1c2466-7bb7-41de-9809-a0b66b7b688a Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:c416b386-c40d-4407-bdaa-a77df67118ca Derived From Document ID : xmp.did:dd5757ec-bd59-4f6f-97ce-eff813af2f2d Derived From Original Document ID: adobe:docid:indd:89ae7fdd-b400-11df-931f-97454b1087d1 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 13.1 (Macintosh) History Changed : / History When : 2018:11:21 13:19:34+01:00 Metadata Date : 2018:11:21 13:20:09+01:00 Creator Tool : Adobe InDesign CC 13.1 (Macintosh) Format : application/pdf Creator : © Mertik Maxitrol GmbH & Co. KG Subject : Mertik Maxitrol Rights : © Mertik Maxitrol GmbH & Co. KG Caption Writer : © Mertik Maxitrol GmbH & Co. KG City : Thale State : Sachsen-Anhalt Country : Deutschland Credit : © Mertik Maxitrol GmbH & Co. KG Source : © Mertik Maxitrol GmbH & Co. KG Marked : True Producer : Adobe PDF Library 15.0 Trapped : False Creator Address : Warnstedter Str.3 Creator City : Thale Creator Region : Sachsen-Anhalt Creator Postal Code : 06502 Creator Country : Deutschland Creator Work Telephone : +4939474000 Creator Work Email : info@mertikmaxitrol.com Creator Work URL : www.mertikmaxitrol.com Image Creator Name : © Mertik Maxitrol GmbH & Co. KG Copyright Owner Name : © Mertik Maxitrol GmbH & Co. KG Copyright Owner ID : © Mertik Maxitrol GmbH & Co. KG MSIP Label d 938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Enabled: True MSIP Label d 938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Site Id: e600ad84-320a-43ef-bfa4-8f5d25019bde MSIP Label d 938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Owner: christa.jaeger@csagroup.org MSIP Label d 938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Set Date: 2019:01:28 15:12:27.0397561Z MSIP Label d 938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Name: Confidential - Label MSIP Label d 938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Application: Microsoft Azure Information Protection MSIP Label d 938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Parent: 289bd36d-23ac-4bc9-9c00-d421e181dc1a MSIP Label d 938dec 7-e 99c-4a 7e-b 377-36be 797db 649 Extended MSFT Method: Manual Page Count : 11EXIF Metadata provided by EXIF.tools