PREVENTIVE MAINTENANCE ROI-S05751 Chart 4-2 (Cont’d) Step Procedure Click on “RMON(Line)(7days/day)” sub-menu button in “PMON (History)”, ---RMON(Line)(1day)--- Maintenance Mode: on Port1 Date Time Status 1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13: 14: 15: 16: 17: 18: 19: 20: 21: 22: RX UNICAST RX BROADCAST RX MULTICAST RX PAUSE RX CEC ERR RX ALIGNMENT ERR RX SYMBOL ERR RX UNDERSIZE RX FRAGMENTS RX 64 RX 65-127 RX 128-255 RX 256-511 RX 512-1023 RX 1024-1536 RX 1537-MAX RX JABBERS TX UNICAST TX BROADCAST TX MULTICAST TX PAUSE TX COLLISION Detailed daily Line (LAN) RMON (Remote Network Monitoring) data are displayed. Note: For the GbE INTFC, there are distinctions for the functions from the 10BASE-T/100BASE-Tx, refer to Notes of above “RMON(Line)(24H/15min)”. 4-12 12 pages ROI-S05751 CORRECTIVE MAINTENANCE 5. CORRECTIVE MAINTENANCE Corrective maintenance done in the field is described in this chapter. Corrective maintenance in the field covers fault isolation, module/unit replacement and alignment. The fault location procedures describes how to isolate module-level/unit-level faults. Faults can be classified into those that cause deterioration of the transmission quality and those that interrupt the traffic due to a malfunction of the equipment. This chapter explains the troubleshooting procedures for equipment faults and the corresponding remedial methods. The purpose of troubleshooting malfunctioning equipment is to restart the service by locating the faulty part and replacing it with a spare. The faults that cause deterioration in the transmission quality are primarily originated by changes occurred in the state of propagation. Therefore, if a decline in the transmission quality or similar fault takes place frequently, the link design will have to be reviewed. During the corrective maintenance, carefully observe the precautions given in Chapter 2, until the alignment is completed. 5.1 Alarm/Status When an alarm event has occurred, At first, check alarm indication on the front of the IDU. Continuously, connect the PC to the LCT jack on the IDU and check alarm/status indication, Meter Reading on the LCT. (a) Check of the ALM LED Indications and LCT Indication A faulty part can be located by checking the ALM LED indicators and LCT Alarm indications. For the explanation of the ALM LED indication, refer to Chapter 2 OPERATING EQUIPMENT in Section II. Also refer to Chapter 2 Alarm/Status in this Section IV APPENDIX LCT OPERATION. (b) Meter Readings Based on the meter readings during periodical inspection with LCT described in Chapter 4, a faulty part can be located by checking if the reading values exceed the permissible ranges. (c) Loopback In the case of an abnormal BER measurement result among the meter reading items, try to distinguish the faulty part by Chart 5.1.1 Loopback. 5-1 CORRECTIVE MAINTENANCE ROI-S05751 5.1.1 Alarm and Status The alarm and status of each module and ODU are displayed. Each items is explained below. ODU TX Power: Indicates the status of the transmitter in the ODU. When the transmission level is decreased 3 dB or more from preset ATPC minimum level, “Alarm” is issued. TX Input: Indicates the status of the ODU input signal from IDU. When the input signal from the IDU is lost, “Alarm” is issued. RX Level: Indicates the status of the received RF signal level of the ODU. When the level decreased below the RX threshold level, “Alarm” is issued. APC: Indicates the status of the synthesizer in the ODU. When any abnormality occurs in the synthesizer, “Alarm” is issued. ODU CPU/Cable Open: Indicates the status of the CPU in the ODU or IF cable, When any abnormality occurs the CPU operation or IF cable is open, “Alarm” issued. Mute Status: Indicates the control status of the ODU TX power output. When the TX power is set to Mute, “On” is issued. LO REF (for XPIC in SONET): Indicates the status of reference LO signal used for V/H signal synchronization. When the reference signal in the ODU is lost, “Alarm” is issued. TX SW Status (for 1+1 configuration): Indicates the TX SW status for the No. 1 or No. 2 CH selection. RX SW Status (for 1+1 configuration): Indicates the RX SW status for the No. 1 or No. 2 CH selection. 5-2 CORRECTIVE MAINTENANCE ROI-S05751 MODEM Unequipped: Module: Indicates the status of the MODEM existence. When the MODEM is loose contact or it is not mounted according to the “Equipment Setup”, “Alarm” is issued. Indicates the status of the modulator-demodulator. When a failure occurred in the modulatordemodulator and as a result of a LSI failure, “Alarm” is issued. LOF: Indicates the frame synchronization status. When the synchronization from DMR is lost, “Alarm” is issued, Frame ID: Indicates the status of ID number against MODEM of opposite station or the other channel in Twinpath configuration. When ID number assignment is improper, “Alarm” is issued. High BER: Indicates the quality severe deterioration status between radio sections. When the signal deteriorates below the threshold preset value, “Alarm” is issued. The settable threshold values are: 1E-3, 1E-4 and 1E-5. Low BER: Indicates the quality unsevere deterioration status between radio sections. When the signal deteriorates below the preset threshold value, “Alarm” is issued. The settable threshold values are: 1E-6, 1E-7, 1E-8 and 1E-9. Early Warning: Indicates quality deterioration status. When the signal deteriorates below the preset threshold level, “Alarm” is issued. (When the Early Warning is used for protection switchover in 1+1 configuration, RX Hitless Switch is operated.) The preset threshold level is less than 1E-9. MOD: Indicates the operating status of the MOD. When any failure occurs in the modulator section, “Alarm” is issued. DEM: Indicates the operating status of the DEM. When any failure occurs in the demodulator section, “Alarm” is issued. 5-3 CORRECTIVE MAINTENANCE ROI-S05751 Input Voltage: Indicates the power supply input voltage status. When power supply is exceeding the limited, “Alarm” is issued. Power Supply: Indicates the operating status of the power supply. When power supply is abnormal, “Alarm” is issued. IF Cable Short: Indicates the status of IF cable between IDU and ODU. When a short circuit is caused between ODU and the IDU, “Alarm” is issued. Cable EQL: Indicates the status of IF cable equalizer. When equalizer characteristics control is lost, “Alarm” is issued. XIF (for XPIC in SONET): Indicates the status of XIF input signal of the Main Master IDU and Sub Master IDU. When the XIF input signal is lost, “Alarm” is issued and XPIC function is reset. XPIC Status (for XPIC in SONET): Indicates the status of XPIC operation. When the XPIC function is reset, “Reset” is indicated and the “Reset” LED on the front panel is lit. XREF (for XPIC in SONET): Indicates the status of reference CLK signal used for V/H signal synchronization. When the reference OSC in the MODEM failure occurs, “Alarm” is issued. Linearizer Function: Indicates the status of linearizer function. OPR: When the linearizer function is used. NO OPR:When the linearizer function is not used. In this case, TX output power decreases approx. 4 dBm from a standard value. N/A: Linearizer: 5-4 When the ODU linearizer function. is used without Indicates the linearizer operating status. When linlearizer operation is improper in OPR condition, “Alarm” is issued. CORRECTIVE MAINTENANCE ROI-S05751 ATPC Power Mode: Indicates the status of ATPC operation mode. When the ATPC function is improper, stop the control and maintain the TX output level at HOLD/MAX/MIN selectable. INTFC (Main/Sub) INTFC(1/2) Module: Indicates the operating status of the ( ) INTFC. When any failure occurs in the INTFC(1/2) Module, “Alarm” is issued. INTFC(1) Unequipped: Indicates the existence status of the ( ) INTFC. When the ( ) INTFC(1) is not equipped, “Alarm” is issued. INTFC(2) Unequipped (for SONET): Indicates the existence status of the ( ) INTFC. When the ( ) INTFC(2) is not equipped, “Alarm” is issued. INTFC(1/2) Type Mismatch: Indicates the mounted status of the ( ) INTFC. When the INTFC(1/2) type is not coincided with the inventory list, “Alarm” is issued. INTFC(1) In-Phase: Indicates the received signal DADE status between No. 1 and No. 2 at STM/( )E1 INTFC. When the received signal delay time is out of permissible range, Outphase alarm is issued. OC-3(1) LOS (MUX) (for SONET): Indicates the input signal status of the OC-3 from MUX. When the input is disconnected, “Alarm” is issued. OC-3(1) LOF (MUX) (for SONET): Indicates the input signal status of the OC-3 from MUX. When the input signal is out of frame synchronization, “Alarm” is issued. E-BER(1) (MUX) (for SONET): Indicates Excessive-BER of the input OC-3 signal from MUX. When the signal deteriorates below the preset threshold level, “Alarm” is issued. The settable threshold values are 1E-3, 1E-4 and 1E-5. OC-3(1) SD (MUX) (for SONET): 5-5 CORRECTIVE MAINTENANCE ROI-S05751 Indicates the input signal status of the OC-3 from MUX. When the signal deteriorates below the preset threshold level, “Alarm” is issued. The settable threshold values are 1E-6, 1E-7, 1E-8 and 1E-9. OC-3(1) LOS (DMR) (for SONET): Indicates the signal status of the OC-3 from DMR. When the input is disconnected, “Alarm” is issued. 5-6 CORRECTIVE MAINTENANCE ROI-S05751 OC-3(1) LOF (DMR) (for SONET): Indicates the status of the input OC-3 signal from DMR. When the input signal is out of synchronization, “Alarm” is issued. OC-3(1) E-BER (DMR) (for SONET): Indicates Excessive-BER of the input OC-3 signal at the Radio side. When the signal deteriorates below the preset threshold level, “Alarm” is issued. The setable threshold values are 1E-3, 1E4 and 1E-5. OC-3(1) SD (DMR) (for SONET): Indicates the input signal status of the OC-3 from DMR. When the signal deteriorates below the preset threshold level, “Alarm” is issued. The setable threshold values are 1E-6, 1E-7, 1E-8 and 1E-9. OC-3(1) TF (for SONET): Indicates the signal interruption status. Indicates when MS-AIS Generation is set to “Disable”. When OC-3 output signal of OC-3 INTFC is stopped, “Under Execution” is indicated. LAN Link (Port ( )) (LAN INTFC for SONET): Indicates the status of Link between related equipment and Port ( ). Indicates “Link” when the Port is linked with related equipment and indicates “Alarm” in other case. LAN Collision (Port ( )) (LAN INTFC for SONET): Indicates the status of Collision in Half Duplex mode. In Full Duplex mode, “Normal” is always displayed. Indicates status when Port ( ) is in collision condition. Link Loss Forwarding (LLF) (Port ( )) (LAN INTFC for SONET): Indicates the operating status during the fault in opposite station or when the link of local Port ( ) LAN is disconnected by the fault of radio section. When any failure occurs in the MAIN INTFC, “Alarm” is also issued. Speed & Duplex: (Port ( )) (LAN INTFC for SONET): Indicates the operating mode of Port ( ). CTRL CTRL Module: Indicates the operating status of the CTRL. When any failure occurs in the CTRL Module, “Alarm” 5-7 CORRECTIVE MAINTENANCE ROI-S05751 is issued. MMC: Indicates the MMC status. When the mounted MMC is detected, “On” is displayed. APS SW Fail (for APS in SONET): Indicates the APS status of the APS system. When the APS switchover failure occurs, “Alarm” is issued. APS Online Status (for APS in SONET): Indicates online channel on the APS system. XCTRL (for XPIC in SONET): Indicates the status of control signal between Main Master IDU and Sub Master IDU. When the out of control condition occurs, “Alarm” is issued. XPIC Mode Mismatch (for XPIC in SONET): Indicates the status of the Main Master IDU and Sub Master IDU definition. When the Main Master IDU and Sub Master IDU is not defined properly as like as Main Master-Main Master or Sub Master-Sub Master, “Alarm” is issued. 5-8 CORRECTIVE MAINTENANCE ROI-S05751 5.1.2 Control Item Control items can be selected only under maintenance mode. As this “Control” is likely to cause disconnection of signal, take care during operation. Details of “Control” item is described as follows: TXSW manual control: Controls manual switchover of the TX SW at the transmitting side in the Hot standby (HS) configuration. RXSW manual control: Controls manual switchover of the RX SW in the 1+1 configuration. The switchover is carried out without traffic interruption when the DADE is Inphase. Adjustment of the delay time of No.1 and No.2 is automatically set. Caution: When the RX SW mode is set to “Forced” in provisioning, RX SW manual control can select either No. 1 or No. 2 RX route though one is alarmed. Then, take care switching to avoid traffic interruption. ATPC manual control: Used when it is required ATPC operation ON/OFF or the change of the transmitting power range in ATPC operation. TX mute: Turns off the transmitter output. CW CONTROL (No.1/2): Used for transmitting a unmodulated carrier wave (CW). Used to confirm the TX frequency stability. APS Manual Control (for APS in SONET): Controls manual switchover (Auto/Working/ Protection) of the Optical Line in the APS system. Caution: When the APS Maintenance mode is set to “Forced” in provisioning, APS Manual Control can select either Working or Protection line though one is alarmed. Then, take care switching to avoid traffic interruption. IF loopback: Used for distinguish equipment failure to ODU or IDU. The input traffic signal from MUX is looped back at IF stage. When no abnormality is found in the signal after IF loopback, it is assumed that the ODU has a problem. 5-9 CORRECTIVE MAINTENANCE ROI-S05751 Since the control is not interlocked with the RX SW, the RX SW control is needed to select CH which it is IF looped back in 1+1 configuration. Main Loopback (NEAR END) (for SONET)/ Main Loopback (NEAR END) INTFC (1) or (2) (for SONET APS)/: Used for distinguish equipment failure to MUX equipment or radio equipment. The input signal from MUX is looped back to the MUX. When no abnormality is found in the signal with NEAR END loopback, it is assumed that the radio equipment (IDU or ODU) has a problem. Main Loopback (FAR END) (for SONET): Used for distinguish equipment failure to MUX equipment or radio equipment. Signal is looped back at the IDU of the opposite station. When no abnormality is found in the signal through FAR END loopback, it is assumed that the local radio equipment (IDU or ODU) has no problem. Note: This function is unavailable when 2-WAY/XC is enabled. DADE Adjust: Sets the DADE for Hot Standby SD/Twinpath configuration. Selects to make INTFC status Inphase. Notes: 1. The DADE control applies in 1+1 configuration to adjust delay time for RX hitless switching when the INTFC status is indicated Outphase. 5-10 CORRECTIVE MAINTENANCE ROI-S05751 2. The DADE adjustment is needed in initial lineup or when the IF CABLE is replaced. It is not needed readjustment when the INTFC status is indicated Inphase. LAN Device Reset (for LAN transmission only): Used for reset control to LAN interface Port 1 or Port 2. Linearizer Control: Sets Auto/Forced Reset of linearizer function. Forced Reset: When the linearizer function is not used. Auto: When the linearizer function is used. RF SUB Band select: Used for changing the ODU sub band for radio link depending on the RF frequency assignment. Antenna Alignment Mode: The Antenna Alignment Mode is used for extending the dynamic range of the NLITE E Monitor unit. In order to measure in high range of AGC V, it is mandatory required to set Antenna Alignment Mode to ON. If not it set to ON, the indicated AGC voltage is not guaranteed value. For the antenna orientation, set the TX power to the required level by MTPC mode at the opposite site. Note: It is necessary to set to Antenna Alignment Mode when monitor the RX level with the NLITE E Monitor unit. ALS Restart (for SONET optical interface): Sets the duration that the laser is emitted when ALS manual restart for test is performed. XPIC Control Local (for XPIC in SONET): Resets the XPIC function for Local IDU when propagation is deteriorated, either MODEM or ODU of Main Master or Sub Master is a failure or perform the link test. XPIC Control Remote (for XPIC in SONET): Resets the XPIC function for the IDU in the opposite station when either MODEM or ODU of Main Master or Sub Master in the local station is a failure or perform the link test. 5-11 CORRECTIVE MAINTENANCE ROI-S05751 5.1.3 Loopback When loopback condition is necessary, set the system to loopback condition. (see Chart 5-1) When there is an interruption of signals, use the STM/SONET/PDH analyzers and isolate the faulty section by checking the traffic signal by loopback. Setup the test equipment according to the following diagrams for PDH or SONET configuration. RECEIVING END TRANSMITTING END IDU STM/SONET ANALYZER C/N (O/E) CONV RST (Near End Loopback) MOD ODU ODU TX RX IDU RST DEM (IF Loopback) N/C (E/O) CONV (Far End Loopback) PC STM/SONET ANALYZER N/C (E/O) CONV RST OC-3 INTFC DEM MODEM RX TX MOD RST MODEM C/N (O/E) CONV OC-3 INTFC Fig. 5-1 Loopback Diagram for Fault Isolation for SONET Note: The IF LOOPBACK and the RX SW is not operated interlock. In 1+1 configuration, The RX SW switching is needed to select the same CH that is testing in IF LOOPBACK. When the RX SW manual control is disable, set it to Forced mode in Provisioning. 5-12 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-1 Loopback Control Step Procedure For the LCT operation, refer to Chapter 6 of LCT Operation in Appendix of this Section IV. This chart contains: A. Preparation B. IF Loopback Control C. Main Loopback (Near End) Control (SONET) D. Main Loopback (Far End) Control (SONET) If loopback operation is performed, timing loop may occur (timing loop is described in ITU-T Recommendation G.781). Step Procedure Caution: The Loopback control affects the radio link connection. 1. Loopback control operation is not performed at the same time, or perform the Loopback reset control and perform either Loopback mode. • IF Loopback • Near End Loopback • Far End Loopback 2. Loopback operation is not performed with an opposite station simultaneously. 3. Far End Loopback control will be canceled when radio link failure occurs under the control has been executed. A. PREPARATION Set up the BER measurement, (refer to Fig. 5-3) Connect the LCT port and the USB port with a USB cable, (see Fig. 2-2 in Chart 2-2) Login LCT with User name “Admin” and Admin password, 5-13 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-1 (Cont’d) Step Procedure Click on the “Maintenance” button in “LCT MENU”, LCT MENU Alarm/Status Equipment Setup Inventory AUX I/O Maintenance Provisioning Metering PMON(History) Maintenance1 Maintenance2 Click on the “Maintenance1” menu, Click on the control button “On” and click “Set” button, to set to Maintenance On mode, For 1+1 configuration, switchover the TX SW and RX SW for the channel is to be set loopback, (Refer to Chart 2.3 Manual Switchover Operation) Click on the “IF Loopback ( )” button in “Maintenance1” menu and click on the setting button “On”, Note: The control affects Radio link connection. ---Maintenance1--Item Maintenance Value On IF Loopback (No.1) On IF Loopback (No.2) Off Setting Off On Set Off Off On On Set Set Note:The control applies to IF loopback in local MODEM. 5-14 Click on the “Set” button, 10 Click on the Alarm/Status on LCT MENU to check the status, 11 Refer to Fig. 5-7 to 5-9 Troubleshooting Flowchart to diagnose the problem, 12 Click on the setting button “Off” of the IF Loopback ( ) and click on the “Set” button, CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-1 (Cont’d) Step Procedure For OC-3 (E) 13 Click on the setting button “On” and click on the “Set” button, ---Maintenance1--Item Maintenance Value On Main Loopback (Near End) Main Loopback (Far End) On Off Setting Off Off Off On On On Set Set Set 5-15 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-1 (Cont’d) Step Procedure For OC-3 (O) (APS) 14 Click on the “Main Loopback (Near End)” button in “Maintenance1” menu, click on the setting button “INTFC ( )” and click on the “Set” button, ---Maintenance1--Item Maintenance Value On Main Loopback (Near End) INTFC (1) Main Loopback (Near End) INTFC (2) Main Loopback (Far End) On Off Off 5-16 Setting Off Off Off Off On On On On Set Set Set Set 15 Click on the Alarm/Status on LCT MENU to check the status, 16 Refer to Fig. 5-7 to 5-9 Troubleshooting Flowchart to diagnose the problem, 17 Click on the setting button “Off” of the Main Loopback (Near End) and click on the “Set” button, 18 Click on the setting button of Main Loopback (Far End) in “Maintenance 1” menu and click on the “Set” button, 19 Click on the Alarm/Status on LCT MENU to check the status, 20 Refer to Fig. 5-7 to 5-9 Troubleshooting Flowchart to diagnose the problem, 21 Click on the setting button “Off” of the Main Loopback (Far End), 22 Reset control for TX RX SW to “Off”, 23 Reset Maintenance mode to “Off”. CORRECTIVE MAINTENANCE ROI-S05751 5.1.4 BER Measurement Chart 5-2 BER Measurement Apparatus: Digital Multimeter with test leads Screwdriver SONET/SONET Analyzer (for SONET) Optical Variable Attenuator (for OC-3 Optical Interface only) Headset Step Procedure A. 4P LAN INTERFACE Note: The BER measurement can not be performed for the channel which is set to Not Used or the channels shared with LAN. TRANSMITTING END 4P LAN INTFC ! IF IN/OUT XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV PULL ALM PWR ! IF IN/OUT XIF IN XIF OUT XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV PORT 1 PORT 2 100M PORT 3 PORT4 PROTECT PULL PWR 100M LCT NMS NE AUX/ALM SC IN/OUT EOW CALL ALM 100M 100M XIF IN XIF OUT PASOLINK NEO MMC MAINT MEMORY IDU 5-17 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-2 (Cont’d) Step Procedure At both transmitting and receiving ends, set the BER test set as follows: Note: Operation of the TX SW and RX SW are not required in 1+0 system for the following. In HS system, set the TX SW to No.1 or No.2 to “On” condition at transmitting end (refer to Chart 2-3), At receiving end, set the RX SW to either No.1 or No.2 to “On” condition, Measure BER at required CH and confirm that the values are indicated as follows: Requirement: 1 x 10–12 or less 5-18 At receiving end, change setting of the RX SW to opposite No.1 or No.2 from it in step 5 and confirm that the measured value satisfies requirement as in step 6, Change setting of the TX SW to opposite No.1 or No.2 from it in step 4 and confirm that the measured value satisfies requirement given in step 6, At receiving end, change setting of the RX SW to opposite No.1 or No.2 from it in step 7 and confirm that the measured value satisfies requirement given in step 6, Restore all connections and controls to normal. CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-2 (Cont’d) Step Procedure B. OPTICAL INTERFACE Caution: To avoid damage to your eyes, do not stare into laser beam or view directly with optical instruments. (Class 1 Laser Product). At the transmitting end, disconnect OPT cable from the STM1 IN connector on the OC-3 INTFC (see Fig. 5-2), TRANSMITTING END OC-3 INTFC ! IF IN/OUT XPIC CTRL ! IF IN/OUT XIF IN XIF OUT XPIC CTRL TX RX XPIC RESET TX RX XPIC RESET PWR ODU MD/ CBL SELV PWR ODU MD/ CBL SELV PULL (Blank) ALM PWR OC-3 OUT OC-3 IN ONLINE PROTECT PULL PWR STM/SONET ANALYZER XIF IN XIF OUT OPTICAL VARIABLE ATTENUATOR * OC-3 (OPT) IN LCT NMS NE AUX/ALM SC IN/OUT EOW CALL PASOLINK NEO MMC MAINT MEMORY IDU IDU RECEIVING END OC-3 INTFC ! IF IN/OUT XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV ! IF IN/OUT XIF IN XIF OUT PULL (Blank) ALM PWR OC-3 OUT OC-3 IN ONLINE XIF IN XIF OUT STM/SONET ANALYZER OC-3 (OPT) OUT PROTECT PULL PWR LCT NMS NE AUX/ALM SC IN/OUT EOW CALL PASOLINK NEO MMC MAINT MEMORY IDU IDU Equipped with OC-3 Optical Interface Fig. 5-2 BER Measurement for OC-3 Signal At the receiving end, disconnect the OPT cable from the STM1 OUT connector on the OC-3 INTFC (see Fig. 5-2), At both transmitting and receiving ends, set the STM/SONET Analyzer as follows: 5-19 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-2 (Cont’d) Step Procedure OC-3 INTFC(OPTICAL) • Bit rate • Code format • Level IN OUT : 155.52 Mbps : OC-3, NRZ S-1.1 : −8 to −28 dBm/ L-1.1 −10 to −34 dBm : −8 to −15 dBm/ 0 to −8 dBm • Wave length IN : 1310 nm OUT : 1310 nm Note: Operation of the TX SW and RX SW are not required in 1+0 system. In HS system, set the TX SW to No.1 or No.2 to On condition at transmitting end, (refer to Chart 2-3) At receiving end, set the RX SW to either No.1 or No.2 to On condition, Measure BER and confirm that the values are indicated as follows: Requirement: 1 x 10–12 or less At receiving end, change setting of the RX SW to opposite No.1 or No.2 from it in step 5 and confirm that the measured value satisfies requirement given in step 6, Change setting of the TX SW to opposite No.1 or No.2 from it in step 4 and confirm that the measured value satisfies requirement given in step 6, At receiving end, change setting of the RX SW to opposite No.1 or No.2 from it in step 7 and confirm that the measured value satisfies requirement given in step 6, 10 5-20 Restore all connections and controls to normal. CORRECTIVE MAINTENANCE ROI-S05751 5.1.5 Trouble Shooting Flow When alarm condition occurs, red alarm LEDs on the IDU are lit except when there is a power supply failure. Faults can be distinguished using the LED indicators on the front panel of the IDU. Connect the LCT to the equipment and check the equipment conditions in according with the flow chart are shown in Fig. 5-3 to Fig. 5-5. Is ODU ALM indicator (red) on the IDU lighted? YES Is IDU ALM indicator (red) on the IDU lighted? NO Connect the LCT to the IDU and check ALARM/STATUS menu. Check every items whether indicated status is alarm or normal. YES Are both IDU and ODU ALM indicators (red) flashing? NO Is TX Input indicated normal? NO YES Check the IF cable connection and connectors whether the cable is open or short circuit. The IF cable type, cable length and cable loss are used standard. YES YES Change the IF cable to standard. Replace the ODU with a spare. Is TX power of the ODU is indicated normal? YES NO For XPIC NO YES Is LO REF indicated normal? Is APC of the ODU is indicated normal? NO Is XREF (MODEM) indicated normal? YES NO NO Is ODU CPU is indicated normal? YES NO Replace the ODU with a spare. YES Check the IDU section. Reset CPU of the ODU. NO Replace the ODU with a spare. Is TX power vary with ATPC manual control? Is ODU ALM is indicated normal? YES End NO YES Check the RX section of the ODU. Replace the ODU with a spare, if TX power alarm continues when temperature is improved. Replace the ODU with a spare. Fig. 5-3 ODU TX Section Troubleshooting Flowchart 5-21 CORRECTIVE MAINTENANCE ROI-S05751 Is ODU ALM indicator (red) on the IDU lighted? YES Is IDU ALM indicator (red) lighted? NO Connect the LCT to the IDU and check ALARM STATUS menu. Check every items whether indicated status is Alarm or Normal. YES Are both IDU and ODU ALM indicators (red) flashing? NO Is RX Level indicated Normal? YES Check the IF cable connection and connectors whether the cable is open or short circuit. YES Check the ODU TX section. Is APC of the ODU is indicated Normal? YES NO Reset CPU of the ODU Is ODU ALM is indicated Normal? YES NO NO For XPIC NO Is ODU CPU is indicated Normal? Is RXLEVEL by RSL monitor vary at random interval? YES Check fading or interference. YES Are frequency value at opposite site and local site correct? NO NO Is ODU TX section are checked? YES Set proper frequency. YES End Check the TX section of the ODU. Replace the ODU with a spare. Check Antenna system or Replace the ODU with a spare. Fig. 5-4 ODU RX Section Troubleshooting Flowchart 5-22 NO CORRECTIVE MAINTENANCE ROI-S05751 Is IDU ALM indicator (red) on the IDU lighted? YES Is ODU ALM indicator (red) on the IDU lighted? Connect the LCT to the IDU and check ALARM STATUS menu. Check every items whether indicated status is Alarm or Normal. NO YES Is PWR LED on the MODEM lit? YES NO Replace Fuse in the MODEM. Is IF Cable indicated Short? YES NO Is AIS or MS-AIS Received indicated Normal? YES Is CH Usage indicated Normal? YES Is IDU indicated Normal? Is MOD/DEM indicated Normal? NO YES NO YES YES NO Set CH usage correct. Is status of LAN INTFC indicated Normal? YES Select IF Loopback from Maintenance1 menu in the Maintenance Menu on the LCT. NO Check associated DTE at local site. YES Check the IF cable connection and connectors whether the cable is open or short circuit. NO Check associated DTE at opposite site. YES Are both IDU and ODU ALM indicators (red) flashing? NO Is AIS Generated indicated Normal? Is MOD indicated Normal? NO Perform LAN device reset and check LAN cable or associated external equipment. NO Is MOD/DEM indicated Normal? NO Replace the MODEM with a spare. For XPIC YES Is Output LOS indicated Normal? YES NO Is Input LOS indicated Normal? NO Is XREF indicated normal? NO YES Connect the SONET Analizer for BER measurement. Check associated DTE and cable connection. Select Far End loopback from Control menu in the Maintenance Menu on the LCT. Display ALARM/STATUS items from main menu on the LCT again. Is Output LOS indicated Normal? YES Is XIF indicated normal? Replace the MODEM with a spare. NO YES Check the XIFcable, IDU and ODU of the opposite pol. CH or setting of the opposite station. NO ( ) INTFC faulty. Replace the ( ) INTFC YES Check associated DTE and cable connection at opposite site. Fig. 5-5 IDU Section Troubleshooting Flowchart 5-23 CORRECTIVE MAINTENANCE ROI-S05751 5.2 Replacement The replacement procedures of the IDU and ODU is described below. 5.2.1 ODU Replacement The procedures for replacing the ODU with a spare are given in the Chart 5-3. The label attached to the side of ODU indicates the ODU type (see Fig 5-6). To replace the ODU, prepare another ODU of the same type as indicated on the label of the failed one. Check the name plate of the spare ODU. When the indicated items are coincided, the ODU can be replaced. Caution: Do not remove/connect the IF cable with the IDU power ON. Turn the IDU power OFF before connecting/ disconnecting the IF cable, or equipment may be damaged. Caution: To avoid microfonic properties, occurrence of bit errors, when installing the ODU on the HYB or OMT, protect the ODU from mechanical knocks which is not be replaced. NLITE E 0678 TRP-( )G-1B OUTDOOR UNIT (NHG) SHIFT FREQUENCY (NWA-009034) SERIAL No. DATE WEIGHT 3.5kg/ - 48V 0.5A NEC Corporation TOKYO JAPAN Non-ionizing radiation NLITE E RX LEV MON IFL FG Power down IDU before disconnection or connection of cable. 0678 TRP-( )G-1B OUTDOOR UNIT (NHG) SHIFT FREQUENCY (NWA-009034) MHz SUB BAND MHz TX FREQUENCY SERIAL No. TX HIGH/LOW DATE WEIGHT 3.5kg/ - 48V 0.5A NEC Corporation TOKYO JAPAN CAUTION 6-38 GHz ODU MADE IN JAPAN -48V INPUT CAUTION NLite E TX HIGH/LOW MHz SUB BAND Non-ionizing radiation MADE IN JAPAN -48V INPUT Power down IDU before disconnection or connection of cable. Fig. 5-6 ODU Type and Frequency Indication Label Note: Before replacing the ODU in XPIC, perform the control of XPIC Local and XPIC Remote Reset by the LCT for Main Master or Sub Master channel that is to be used online. The mounting and demounting the ODU from/to antenna, refer to the Installation and Initial Line up in Section III. 5-24 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-3 ODU Replacement Apparatus: T type hexagonal driver Step Procedure REMOVING For 1+1 configuration, switchover the TX SW and RX SW for the standby channel is to be replaced, Turn off the power switch on the MODEM which is connected to the ODU is to be replaced, Remove the self-bonding tape from the IF IN/OUT connector, Disconnect the IF cable from the IF IN/OUT connector on the ODU, Disconnect ground cable from the FG terminal on the ODU, Loosen four bolts fixed the ODU with a T type hexagonal driver, SCREWS NLite E RX LEV MON GROUND CABLE IFL FG IF CABLE SCREWS ODU Remove the ODU from the bracket, 5-25 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-3 (Cont’d) Step Procedure MOUNTING When the ODU is used for vertical polarization, rotate the ODU so that the plate marked V is on top, Note: Remove the protection metallic plate covering the waveguide hole on ODU. When the ODU is used for horizontal polarization, remove the guide pin fixed on the plate marked V, PLATE MARKED V Guide Pin UP NLite E RX LEV MON IFL FG V POLARIZATION ODU 10 Insert the guide pin removed in step 8 behind of the plate marked H, 11 Rotate the ODU so that the plate marked H is on top, PLATE MARKED H Guide Pin UP IFL NLite E RX LEV MON FG ODU 5-26 H POLARIZATION CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-3 (Cont’d) Step 12 Procedure Fit the spare ODU onto the bracket, Note: Be careful not to damage the flange and O-ring. 13 Mount the spare ODU onto the bracket and tighten the four screws on the ODU, 14 Reconnect the IF cable to the IF IN/OUT connector on the ODU, 15 Wrap twice the IF IN/OUT connector with self-bonding tape for waterproofing. (see Fig. 5-7 (1/2) and (2/2)) 16 Reconnect ground cable removed in step 4 to FG terminal, 17 Turn on the power switch on the IDU. 5-27 CORRECTIVE MAINTENANCE ROI-S05751 ANT POLE (*) ANT POLE HYB ODU ODU (*) 6-8 GHz BAND ODU Wrap twice the IF IN/OUT connector with self-bonding tape for waterproofing. 6-8 GHz BAND self-bonding tape stretch Note: * These parts should be wrapped by self-bonding tape for waterproof. ODU twice Fig. 5-7 Location of Connector for Waterproof (1/2) 5-28 a half of tape width CORRECTIVE MAINTENANCE ROI-S05751 Wrap twice the IF IN/OUT connector with self-bonding tape for waterproofing. self-bonding tape stretch ODU a half of tape width twice CONNECTOR This part should be wrapped by self-bonding tape for waterproof. ODU SELF-BONDING TAPE IF CABLE ODU ODU SELF-BONDING TAPE IN CASE OF L−ANGLE IF CABLE Note: The self-bonding tape should be prepared by customer. Fig. 5-7 Location of Connector for Waterproof (2/2) 5-29 CORRECTIVE MAINTENANCE ROI-S05751 5.2.2 IDU and Module Replacement The procedures for replacing IDU/module with a spare are given in the Chart 5-4. Chart 5-4 IDU and Module Replacement Caution: Persons performing maintenance must take necessary steps to avoid electro-static discharge which may damage the modules or cause error. Wear a conductive wrist strap connected to the grounded (G) jack on the front of the equipment shelf. This will minimize static build-up during maintenance. (see Fig. 2-1 in Chapter 2). Caution: Do not remove/connect the IF cable with the IDU power ON. Turn the IDU power OFF before connecting/ disconnecting the IF cable, or equipment may be damaged. This chart contains: A. Module replacement B. IDU replacement Apparatus: Suitable Screwdriver Step Procedure A. MODULE REPLACEMENT Note: Be careful do not touch the electric parts and printed circuit on the module. Note: The top surface of the IDU above MODEM is hot in operation. Note: The maintenance personnel should report starting replacement from a station to the relevant station. 5-30 Referring to Chart 2-1, set the IDU to maintenance ON condition by LCT, For 1+1 configuration, switchover the TX SW and RX SW for the standby channel from the working channel which is to be replaced, CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Removing MODEM When the MODEM will be replaced, turn off the power switch on the corresponding MODEM which is to be replaced, Disconnect cables as following order, (1) Disconnect power supply cable from SELV connector. (2) Disconnect IF cable from IF IN/OUT connector. The adapter is reused. (3) Disconnect ground cable from the ground terminal. Loosen two screws on the MODEM module, (See Fig. 5-8) Remove the MODEM module from the IDU shelf, Mounting MODEM When the MODEM is replaced, check that the power switch is set to Off position, Align the MODEM to the shelf, then push it in until the multipin connector firmly fits, Tighten the two screws on the module, Connect cables as following order, (1) Connect ground cable to the ground terminal. (2) Connect IF cable with adapter to IF IN/OUT connector. (3) Connect power supply cable to SELV connector. Turn on the power switch on the MODEM, Check that the MODEM is normal on the Alarm/Status display, Check that the installed MODEM module exists in the INVENTRY list, Check the operation of the replaced MODEM module, Referring to Chart 2-1, set the IDU to maintenance OFF condition by LCT. 5-31 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Replacement of the OC-3 (Optical) INTFC in APS Caution: Do not stare at the laser beam or look at it directly with optical instruments. Otherwise, it may hurt your eyes (Class 1 Laser Product) For the OC-3 (OPTICAL) INTFC replacement in APS configuration, the OC-3 (OPTICAL) INTFC can be replaced without power OFF and not affect traffic when doing replacement as following order. (When the traffic is not applied to the system, turn off the power switch before performing the replacement of the module.). The maintenance personnel should report starting replacement from a station to the relevant station. Referring to Chart 2-1, set the IDU to maintenance ON condition by LCT, Click on “APS Manual Control” from “Maintenance 1” menu, Switchover the module is to be replaced to OFF LINE. Click on the “Working” or “Protection” button and click on the “Set” button, then, value turns to selected side for ON LINE, ---Maintenance1--Item Maintenance Value On APS Manual Control Working Off On Auto Working Set Protection Set Check that the “ON LINE” LED is unlit on the OC-3 (OPTICAL) INTFC which is to be replaced, Set the PROTECT SW on the module front to ON (for upper position), then the MAINT LED starts the blink, The module can be replaced under the MAINT LED is blinking, 5-32 Setting (a) There is need to install the MMC. The MEMORY LED blinks during the data is uploading to the MMC, the MAINT LED starts the blink after upload of the data has been completed. (b) When the CTRL becomes the PROTECT mode, LCT connection takes timeout. Disconnect optical cables from OC-3 OUT and OC-3 IN connectors on the OC-3 (OPTICAL) INTFC module is to be replaced, CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Loosen two screws on the OC-3 (OPTICAL) INTFC module is to be replaced, (See Fig. 5-11) Extract the OC-3 (OPTICAL) INTFC module from the IDU shelf, Note: Be careful not catch the module on the cable when extracting the module. If the module caught on the live cables, it may be caused radio link error. Install the spare OC-3 (OPTICAL) INTFC module into the IDU shelf, 10 Connect the OPT cables to the OC-3 OUT and OC-3 IN connectors on the OC-3 (OPTICAL) INTFC module, 11 Set the PROTECT SW on the module front to OFF (for lower position), then the MAINT LED turns to lit, When the PROTECT SW turns to OFF, it will appear momentary that events have been latched. 12 Check that the OC-3(1) and OC-3(2) are normal on the Alarm/ Status display, 13 Check that the installed OC-3 (OPTICAL) INTFC module exists in the INVENTRY list, 14 Check the operation of the replaced OC-3 (OPTICAL) INTFC module, 15 Click on the “Auto” button and click on the “Set” button, then, value turns to Auto, 16 Click on the “Off” button of Maintenance and Click on the “Set” button, 17 This work finishes. 5-33 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure System Upgrade for APS of OC-3 (OPTICAL) INTFC Caution: To avoid eye damage, do not stare at the laser beam or look at it directly with optical instruments. (Class 1 Laser Product) For the change of OC-3 (OPTICAL) INTFC system to the APS system, perform system setup without power OFF and not affect traffic when doing replacement as following order. The maintenance personnel should report starting replacement from a station to the relevant station. Referring to Chart 2-1, set the IDU to maintenance ON condition by LCT, Click on the “Equipment Setup” button in “LCT MENU”, then “Equipment Setup” menu is displayed, Select “OC-3 OPT for APS” from pull-down menu of the SUB(PROT), Click on the “Available” setting button of the APS Function, Click on the “SET” button in Common area, then “OK” is displayed in Progress area when the setup is properly executed, ---Equipment Setup--User Interface SONET OC-3 Redundancy Setting 1+1(Hot Standby TERM) INTFC (Main) OC-3(OPTICAL) INTFC (Prot) OC-3 OPT for APS XPIC Usage APS Function Not Used Used(Main Master) Available Modulation Scheme Unavailable 128QAM Transmission Capacity 156MB 5-34 Used(Sub Master) CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Click on the Provisioning button on “LCT MENU”, Click on the “Forced” control button of the APS Maintenance Mode item, ----Condition for APS--APS Maintenance Mode Manual Forced Click on the “SET” button in Common area, then “OK” is displayed in Progress area when the setup is properly executed, In the Maintenance1 menu, Click on the “Working” button of the APS Manual Control and Click on the “Set” button, then, value turns to “Working”, ---Maintenance1--Item Maintenance Value On APS Manual Control Working Setting Off On Auto Working Set Protection Set 10 Remove the blank cover of the Slot2 for OC-3 INTFC(2), 11 Install the OC-3 (OPTICAL) INTFC module into the Slot2, 12 Tighten two screws of the OC-3 (OPTICAL) INTFC module, (See Fig. 5-11) 13 Connect the OPT cables to the OC-3 OUT and OC-3 IN connectors on the OC-3 (OPTICAL) INTFC module, 14 Check that the OC-3(1) and OC-3(2) are normal on the Alarm/ Status display, 15 Check that the installed OC-3 (OPTICAL) INTFC module exists in the INVENTRY list, 16 Check the operation of the installed OC-3 (OPTICAL) INTFC module, 17 Click on the “Auto” button and Click on the “Set” button, then, value turns to Auto, 18 Click on the “Off” button of Maintenance and Click on the “Set” button, 19 This work finishes. 5-35 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure System Change from e/w APS to w/o APS of OC-3 (OPTICAL) INTFC Caution: Do not stare at the laser beam or look at it directly with optical instruments. Otherwise, it may hurt your eyes (Class 1 Laser Product). For the change of OC-3 (OPTICAL) INTFC system of the APS system to without APS system, perform system setup without power OFF and not affect traffic when doing system change as following order. The maintenance personnel should report starting system change from a station to the relevant station. Referring to Chart 2-1, set the IDU to maintenance ON condition by LCT, In the Maintenance1 menu, Click on the “Working” button of the APS Manual Control and Click on the “Set” button, when the Protection side is ON LINE, value turns to “Working”, ---Maintenance1--Item Maintenance Value On APS Manual Control Working Setting Off Auto On Working Set Protection Set Click on the “Auto” button of the APS Manual Control and Click on the “Set” button, When the Working side is ON LINE, check that the APS Manual Control is “Auto” mode, ---Maintenance1--Item Maintenance Value On APS Manual Control Auto 5-36 Setting Off On Auto Working Set Protection Set Click on the “Equipment Setup” button in “LCT MENU”, then “Equipment Setup” menu is displayed, Select “Not Used” from pull-down menu of the SUB(PROT), Click on the “Unavailable” setting button of the APS Function, CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Click on the “SET” button in Common area, then “OK” is displayed in Progress area when the setup is properly executed, Perform step 8 to step 11 when it is needed, ---Equipment Setup--User Interface SONET OC-3 Redundancy Setting 1+1(Hot Standby TERM) INTFC (Main) OC-3(OPTICAL) INTFC (Prot) Not Used XPIC Usage APS Function Not Used Used(Main Master) Available Modulation Scheme Unavailable 128QAM Transmission Capacity 156MB Used(Sub Master) Disconnect optical cables from OC-3 OUT and OC-3 IN connectors on the OC-3 (OPTICAL) INTFC module in the Slot2, 10 Loosen two screws on the OC-3 (OPTICAL) INTFC module is to be replaced, (See Fig. 5-11) 11 Extract the OC-3 (OPT) INTFC module from the Slot2, Note: Be careful not catch the module on the cable when extracting the module. If the module caught on the live cables, it may be caused radio link error. 12 Fit the blank cover with two screws to the Slot2, 13 Click on the “Off” button of Maintenance and click on the “Set” button, 5-37 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Removing OC-3 INTFC, GbE INTFC, CTRL Referring to Chart 2-1, set the IDU to maintenance ON condition by LCT, Note: When the CTRL is a failure, replace it with a spare as explained below. Note: When the CTRL is replaced without power OFF, refer to the “Replacing the CTRL Used MMC or LCT”. ---Maintenance1--Item Maintenance Value On Setting Off On Set Turn off the power switch on the MODEM (both MODEM for 1+1 configuration), Disconnect all the cables connected to the module, Loosen two screws on the module, (See Fig. 5-11), Extract the module, Note: Be careful to avoid catching the module on the cable when extracting the module. If the module is caught on the live cables, it may cause a radio link error. 5-38 CORRECTIVE MAINTENANCE ROI-S05751 1+0 SYSTEM IDU SCREW SCREW MODEM ! IF IN/OUT XPIC CTRL XPIC CTRL TX RX XPIC RESET Gb E INTFC PWR ODU MD/ CBL SELV PULL PULL PWR (Blank Cover) OC-3 IN OC-3 OUT XIF IN XIF OUT TX RX XPIC RESET ! IF IN/OUT XIF IN XIF OUT PWR ODU MD/ CBL SELV PWR NMS NE AUX/ALM EOW CALL MMC MAINT MEMORY IDU SCREW 1+1 SYSTEM IDU MODEM No. 1 ! IF IN/OUT XIF IN XIF OUT Gb E INTFC PWR ODU MD/ CBL SELV PULL XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV PULL XPIC CTRL TX RX XPIC RESET ! IF IN/OUT XIF IN XIF OUT MODEM No. 2 SC IN/OUT SCREW CTRL FG nlite e PROTECT LCT PWR PWR (Blank Cover) OC-3 IN OC-3 OUT LCT NMS AUX/ALM NE SC IN/OUT EOW FG nlite e PROTECT CALL MMC MAINT MEMORY IDU CTRL SCREW SCREW W/O APS SYSTEM IDU ! IF IN/OUT XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV ! IF IN/OUT XIF IN XIF OUT PULL ALM PWR OC-3 OUT OC-3 IN (Blank Cover) ONLINE XIF IN XIF OUT Slot2 OC-3 (OPTICAL) INTFC PROTECT PULL PWR LCT NMS NE AUX/ALM SC IN/OUT EOW ! IF IN/OUT XPIC CTRL ! IF IN/OUT XPIC CTRL TX RX XPIC RESET TX RX XPIC RESET PWR ODU MD/ CBL SELV PWR ODU MD/ CBL SELV PULL ALM PWR OC-3 OUT OC-3 IN ALM OC-3 OUT ONLINE PWR OC-3 IN PROTECT PULL LCT NMS NE AUX/ALM SC IN/OUT EOW CALL ONLINE MAINT MEMORY IDU OC-3 (OPTICAL) INTFC OC-3 (OPTICAL) INTFC XIF IN XIF OUT MMC SCREW E/W APS SYSTEM XIF IN XIF OUT CALL nlite e nlite e MMC MAINT MEMORY IDU Fig. 5-8 Demounting and Remounting Module 5-39 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Mounting OC-3 (OPTICAL) INTFC w/o APS For the OC-3 (OPTICAL) INTFC mounting without APS, install the module as following order, Referring to Chart 2-1, set the IDU to maintenance ON condition by LCT, ---Maintenance1--Item Maintenance Value On Setting Off On Set Turn OFF the power switch on the MODEM, Align the OC-3 (OPTICAL) INTFC to the shelf, then push it in until the multipin connector firmly fits, Tighten the two screws on the module, Connect optical cables to OC-3 OUT and OC-3 IN connectors, Caution: Do not stare at the laser beam or look at it directly with optical instruments. Otherwise, it may hurt your eyes (Class 1 Laser Product). Turn ON the power switch on the MODEM, Check that the “ON LINE” LED is lit on the OC-3 (OPTICAL) INTFC which is replaced, Check that the OC-3(1) is normal on the Alarm/Status display, Check that the installed OC-3 (OPTICAL) INTFC module exists in the INVENTRY list, 10 Check the operation of the installed OC-3 (OPTICAL) INTFC module, 11 Click on the “Off” button of Maintenance and Click on the “Set” button, ---Maintenance1--Item Maintenance Value Off 12 5-40 Setting Off This work finishes. On Set CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Mounting GbE (OPTICAL) INTFC For the GbE (OPTICAL) INTFC mounting, install the module as following order, Referring to Chart 2-1, set the IDU to maintenance ON condition by LCT, ---Maintenance1--Item Maintenance Value On Setting Off On Set Turn OFF the power switch on the MODEM, Align the GbE (OPTICAL) INTFC to the shelf, then push it in until the multipin connector firmly fits, Tighten the two screws on the module, Connect optical cables to 1000BASE-SX OUT and IN connectors, Caution: Do not stare at the laser beam or look at it directly with optical instruments. Otherwise, it may hurt your eyes (Class 1 Laser Product). Turn ON the power switch on the MODEM, Check that the “ON LINE” LED is lit on the GbE (OPTICAL) INTFC which is replaced, Check that the OC-3(1) is normal on the Alarm/Status display, Check that the installed GbE (OPTICAL) INTFC module exists in the INVENTRY list, 10 Check the operation of the installed GbE (OPTICAL) INTFC module, 11 Click on the “Off” button of Maintenance and Click on the “Set” button, ---Maintenance1--Item Maintenance Value Off Setting Off On Set 5-41 CORRECTIVE MAINTENANCE ROI-S05751 Step Procedure OC-3/GbE INTFC, CTRL Referring to Chart 2-1, set the IDU to maintenance ON condition by LCT, ---Maintenance1--Item Maintenance Value On Setting Off On Set Turn OFF the power switch on the MODEM, Check that the switch on the MODEM (both MODEM for 1+1 configuration) is off position, Align the module to the IDU shelf, then push it in until the multipin connector firmly fits, Tighten two screws on the module, Connect all cables to the module, Turn on the power switch on the MODEM. Check that the 4P LAN INTFC, OC-3, GbE INTFC, CTRL is normal on the Alarm/Status display, Check that the installed 4P LAN INTFC, OC-3, GbE INTFC, CTRL module exists in the INVENTRY list, 10 Check the operation of the replaced 4P LAN INTFC, OC-3, GbE INTFC, CTRL module, 11 Click on the “Off” button of Maintenance and click on the “Set” button, ---Maintenance1--Item Maintenance 5-42 Value Off Setting Off On Set CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Replacing the CTRL Using the MMC or LCT. This procedure explains how to replace the CTRL using the MMC or LCT. This procedure is applied when the CTRL is not failed, or when the equipment configuration data are saved into the MMC or LCT/PNMx. Note: If the NMS parameters (Network Config.) can not be restored, then the resetup with the PNMx is required. The Use of the MMC for the CTRL Replacement When the MMC is used, the replacement can be performed without the LCT operation.(The resetup with the PNMx for the Network Config. is necessary.) Insert the MMC into the MMC slot on the CTRL front, (The data size to save is approximately 10 kbyte.) Set the PROTECT SW on the CTRL front to ON position (for upper side). Then, the MAINT LED (amber) on the IDU is lit and the equipment configuration data gather up and the saving of data to the MMC start, When the equipment configuration data gather up and data saving to the MMC has been completed, the MAINT LED on the IDU blinks slowly, (Check that the MAINT LED blinks slowly when remove the CTRL.) Remove the cables connected to the CTRL, loosen two fixed screws and remove the CTRL, Note: Be careful not catch the module on the cable when extracting the module. If the module caught on the live cables, it may be caused radio link error. Prepare the spare CTRL. Set the PROTECT SW on the spare CTRL to ON position (for upper side), (The PROTECT SW setting distinguish the normal start up or protected start up.) Mount the CTRL into the IDU. Check that the MAINT LED on the IDU blinks. Tighten two screws and connect cables removed in step 4. 5-43 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure When the MAINT LED blinks, insert the MMC into the MMC slot on the CTRL front, which has equipment configuration data used in the former CTRL, The download of the equipment configuration data start, the deployment is performed. When the CTRL has been made provision, MAINT LED on the IDU turns to light. Check that the MAINT LED lights and set the PROTECT SW to OFF position (for lower side). Then, the equipment configuration data deploys and data is restored. In the Equipment Setup menu and the Provisioning menu, confirm that the equipment configuration and setting conditions are the same as before replacement. Check that neither alarm is indicated in the Alarm Status. The CTRL replacement finishes. Perform the resetup for the Network Config. since the Network Config. data is not restored. CTRL MPROTECT SW MMC Slot PROTECT LCT NMS NE AUX/ALM SC IN/OUT EOW PASOLINK NEO MMC MAINT MEMORY IDU SCREW SCREW MMC 5-44 CALL MAINTE LED CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Note: If the NMS parameters (Network Config.) can not be restored, then the resetup with the PNMx is required. The Use of the LCT for the CTRL Replacement When the LCT is used, the replacement can be performed without the MMC. (The resetup with the PNMx for the Network Config. is necessary.) Referring to Chart 2-1, set the IDU to Maintenance ON condition by LCT (Check that the MAINT LED lights.), Set the PROTECT SW on the CTRL front to ON position (for upper side). Then, equipment configuration data gather up and the saving of data start, --- Maintenance2 -----Control--- ---PMON Clear--- CPU Reset PMON Clear ---Download--Configuration File Program File Equipment Config. File ---Upload--Configuration File Equipment Config. File ---Date/Time--Date/Time Setting ---Password--Password Setting Select the Maintenance2 from the Maintenance menu, select the Equipment Config. File of Upload. Enter the directory of the file name where the uploaded file will be saved (extension is .cfg), When the upload to the LCT has completed, MAINT LED blinks slowly (Check that the MAINT LED blinks slowly when remove the CTRL.), 5-45 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Remove the cables connected to the CTRL, loosen two fixed screws and remove the CTRL, Note: Be careful to avoid catching the module on the cable when extracting the module. If the module is caught on the live cables, it may cause a radio link error. 5-46 Prepare the spare CTRL. Set the PROTECT SW on the spare CTRL to ON position (for upper side), (The PROTECT SW setting distinguish the normal start up or protected start up.) Mount the CTRL into the IDU. Check that the MAINT LED on the IDU blinks. Tighten two screws and connect cables removed, To download the equipment configuration data to the LCT, select Maintenance2 from the Maintenance menu, select the Equipment Config. File of Download. Enter the directory of the file name where the uploaded file is saved, click on the “Execute” button to start the download. When “Complete” appears in the Progress Status, click on the “Update” button to perform download. When the CTRL has been provisioned, the MAINT LED on the IDU turns to light. Check that the MAINT LED lights, set the PROTECT SW to OFF position (for lower side). Then, the equipment configuration data deploys and data is restored. In the Equipment Setup menu and the Provisioning menu, confirm that the equipment configuration and setting conditions are the same as before replacement. Check that neither alarm is indicated in the Alarm Status. 10 The CTRL replacement finishes. Perform the resetup for the Network Config. since the Network Config. data is not restored. CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Replacing the DC-DC CONV (Optional). When the power is supplied to the SELV of the DC-DC CONV (optional) but the PWR LED of the DC-DC CONV is not lit though the power switch is on, before replacing the DC-DC CONV, check the conduction of the fuse in the DC-DC CONV. Referring to Chart 2-1, set the IDU to maintenance ON condition by LCT, Set the power switch on the MODEM to Off position, Set the power switch on the DC-DC CONV to Off position, PWR LED ! IF IN/OUT XIF IN XIF OUT XPIC CTRL TX RX XPIC RESET − 43V STD Screw ALM ALM −43V/OUT SELV FUSE (250V/8AH) ALM PWR PWR OUT PULL PWR ODU MD/ CBL SELV FG PWR Switch OC-3 OUT OC-3 IN ALM OC-3 OUT ONLINE OC-3 IN PROTECT PULL PWR LCT NMS NE AUX/ALM SC IN/OUT EOW CALL ONLINE FG NLITE E MMC MAINT MEMORY IDU Screw PWR Switch SELV PWR LED Disconnect cables connected to the DC-DC CONV as following order, (1) Disconnect power supply cable from SELV connector, (2) Disconnect power supply cable from −43/OUT connector, (3) Disconnect ground cable from ground terminal, (4) Disconnect ALM cable from ALM terminal, Loosen two screws fixed the DC-DC CONV, Extract the DC-DC CONV from the IDU shelf, Check that the power switch on the spare DC-DC CONV is Off position Mount the spare DC-DC CONV to the IDU shelf, Tighten two screws to fix the DC-DC CONV, 10 Connect cables to the DC-DC CONV as reversed order in step 4, 5-47 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step 5-48 Procedure 11 Turn on the power switch on the DC-DC CONV, 12 Check that PWR LED on the DC-DC CONV is on, 13 Turn on the power switch on the MODEM, 14 Check that PWR LED on the MODEM is on, 15 Check that ALM LED on the IDU is unlited, 16 Set the IDU to maintenance OFF condition by LCT. CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure B. IDU REPLACEMENT REMOVING Turn off the power switch on the MODEM (both MODEM in 1+1 configuration), Disconnect the IF cable, signal cables and the power cable, etc. as following order, (1) Disconnect XPIC CTRL cables from opposite IDU. (XPIC configuration only.) (2) Disconnect XIF coaxial cables from opposite IDU. (XPIC configuration only.) (3) Disconnect OC-3, LAN, Aux. signal cables from connector. (4) Disconnect power supply cable from SELV connector. (5) Disconnect IF cable from IF IN/OUT connector. (6) Disconnect ground cable from the ground terminal Note: The adapter for IF cable connector is reused. As shown in Fig. 5-9, loosen four screws and remove the IDU, MOUNTING Fix the two brackets to desired position on the IDU, if necessary (see Fig. 5-10), Mount the IDU into the original position of the mounting rack and tighten the four screws, Reconnect the IF cables, signal cables and the power cable to the original position as following order, (1) Connect ground cable to the ground terminal (2) Connect IF cable (with adapter) to IF IN/OUT connector. (3) Connect power supply cable to SELV connector. (4) Connect OC-3, LAN, Aux. signal cables to proper connector. (5) Connect XIF coaxial cables to opposite IDU. (XPIC configuration only.) (6) Connect XPIC CTRL cables to opposite IDU. (XPIC configuration only.) 5-49 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-4 (Cont’d) Step Procedure Form the wiring, and fix the cables using cable binder to the mounting rack, Notes: 1. Do not cross the cables on front of indicators and power switch used for maintenance. 2. Take suitable radius to wiring the IF cable. (e.g. 10DFB: 70 cm) Turn on the power switch on the IDU. Hot Surface SCREW Note: Weight 4 kg. Caution: The top surface of the IDU above MODEM is hot in operation. Fig. 5-9 Demounting and Remounting FRONT POSITION CENTER POSITION SIDE VIEW Fig. 5-10 Bracket Mounting Position 5-50 CORRECTIVE MAINTENANCE ROI-S05751 5.2.3 Fuse Replacement When the power is supplied to the SELV but the IDU can not be powered on with the power switch, check the conduction of fuse in the MODEM. Chart 5-5 Fuse Replacement Step Procedure Set the power switch on the MODEM which is not powered to Off position, Disconnect cables connected to the MODEM as following order, (1) Disconnect power supply cable from SELV connector. (2) Disconnect IF cable from IF IN/OUT connector. The adapter is reused. (3) Disconnect ground cable from the ground terminal. Loosen two screws on the MODEM, Extract the MODEM from the IDU shelf, Remove protection cap over the fuse (see Fig. 5-11), Remove the fuse from the fuse holder, Check conduction of the broken fuse using tester, Check conduction of the reserved fuse using tester, Replace the broken fuse with reserved one, 10 Set the replaced fuse to the fuse holder, 11 Cap over the replaced fuse, 12 Mount the MODEM to the IDU shelf, 13 Tighten two screws on the MODEM, 14 Connect cables to the MODEM as reversed order in step 2, 15 Turn on the power switch on the MODEM, 16 Check that power is on. 5-51 CORRECTIVE MAINTENANCE ROI-S05751 (MODEM) (Front) RESERVE Reserve Fuse (6.3A) 21606.3 Fuse RKS-F91000-0107 Fuse Cap Fig. 5-11 Fuse in the MODEM 5-52 CORRECTIVE MAINTENANCE ROI-S05751 When the power is supplied to the SELV of the DC-DC CONV (optional) but the PWR LED of the DC-DC CONV is not lit though the power switch is on, check the conduction of the fuse in the DC-DC CONV. Chart 5-6 DC-DC CONV Fuse Replacement Step Procedure Set the power switch on the DC-DC CONV which is not powered to Off position Disconnect cables connected to the DC-DC CONV as following order, (1) Disconnect power supply cable from SELV connector, (2) Disconnect power supply cable from −43/OUT connector, (3) Disconnect ground cable from ground terminal, (4) Disconnect ALM cable from ALM terminal, Loosen two screws on the DC-DC CONV, Extract the DC-DC CONV from the unit, Put the screwdriver to the groove of the fuse holder and turns the fuse holder counter clockwise, Remove the fuse from the fuse holder, Check conduction of the broken fuse using tester, Remove the reserved fuse as described in step 5, Check conduction of the reserved fuse using tester, 10 Replace the broken fuse with reserved one, 11 Set the replaced fuse to the fuse holder, 12 Put the screwdriver to the groove of the fuse holder and push it into the DC-DC CONV, 13 Turn the screwdriver clockwise until the fuse holder is locked up, (When the fuse holder is locked up, the groove of the fuse holder is set to horizontal as shown in Fig 5-12.) 14 Check and replace another fuse in the same way as from Step 5 to Step 13, 15 Mount the DC-DC CONV to the unit, 5-53 CORRECTIVE MAINTENANCE ROI-S05751 Chart 5-6 (Cont’d) Step Procedure 16 Tighten two screws on the DC-DC CONV, 17 Connect cables to the DC-DC CONV as reversed order in step 2, 18 Turn on the power switch on the DC-DC CONV, 19 Check that power is on. 20 Turn on the power switch on the IDU/DC-DC CONV UNIT, 21 Check that power is on. RESERVE RESERVE (DC-DC CONV) Reserved Fuse Reserve Fuse (8A) GAB250V8 Fuse CBE-006255-001 ! CAUTION HOT SURFACE Avoid contact. Screw − 43V PWR OUT STD ALM FUSE (250V/8AH) Screw PULL PWR SELV ALM −43V/OUT Fuse Holder SELV PWR LED PWR Switch (Front) Fig. 5-12 Fuse in the DC-DC CONV 5-54 CONTENTS ROI-S05749-05FE August, 2007 NEC NLite E 6-38 GHz SONET DIGITAL RADIO SYSTEM Section II OPERATION CONTENTS TITLE PAGE GENERAL •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 1-1 OPERATING EQUIPMENT ••••••••••••••••••••••••••••••••••••••••• 2-1 2.1 IDU Shelf •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 2-4 2.2 CTRL ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 2-5 2.3 MODEM •••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 2-12 2.4 STM-1 INTFC ••••••••••••••••••••••••••••••••••••••••••••••••••••• 2-16 2.5 4P LAN INTFC (Optional) ••••••••••••••••••••••••••••••••••••• 2-18 2.6 GbE INTFC (Optional) •••••••••••••••••••••••••••••••••••••••••• 2-20 2.7 DC-DC CONV (Optional) •••••••••••••••••••••••••••••••••••••• 2-23 2.8 ODU ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 2-25 SYSTEM SETUP •••••••••••••••••••••••••••••••••••••••••••••••••••••• 3-1 3.1 Equipment Setup ••••••••••••••••••••••••••••••••••••••••••••••••• 3-1 3.2 Provisioning Setup ••••••••••••••••••••••••••••••••••••••••••••••• 3-4 3.3 Events and Performance ••••••••••••••••••••••••••••••••••••••• 3-7 3.4 Control ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 3-14 3.5 Setup Description •••••••••••••••••••••••••••••••••••••••••••••• 3-16 3.5.1 Automatic Laser Shutdown Control (OPT INTFC) (SDH) ••••••••••••••••••••••••••••••••••••••••••••• 3-16 3.5.2 Automatic Protection Switching (APS) (OPT INTFC Optional APS Configuration) (SDH) ••••••• 3-18 3.5.3 Automatic Transmitter Power Control •••••••••••••••••••• 3-23 3.5.4 Loopback Control •••••••••••••••••••••••••••••••••••••••••••••• 3-27 3.5.5 Link Loss Forwarding Control (LAN) •••••••••••••••••••••• 3-27 3.5.6 MS-AIS Generation (SDH) •••••••••••••••••••••••••••••••••••• 3-28 3.5.7 Cross Polarization Interference Canceller (XPIC Reset Control •••••••••••••••••••••••••••••••••••••••••••••••••••• 3-30 3.5.8 Network Management (Optional) ••••••••••••••••••••••••••• 3-31 CL-1 CONTENTS ROI-S05749 TITLE CL-2 2 pages PAGE 3.5.9 Functionality Classification ••••••••••••••••••••••••••••••••• 3-32 3.6 Protection Switching •••••••••••••••••••••••••••••••••••••••••• 3-33 3.6.1 1 + 1 Twin-path System ••••••••••••••••••••••••••••••••••••••• 3-33 3.6.2 Hot-standby System ••••••••••••••••••••••••••••••••••••••••••• 3-33 3.6.3 Switchover Control ••••••••••••••••••••••••••••••••••••••••••••• 3-34 ROI-S05749-05FE August, 2007 CONTENTS CL-3 GENERAL ROI-S05749 1. GENERAL This section provides instructions for operation of the 6 to 38 GHz SONET microwave radio system. This section describes interface terminals and jacks, controls, indicators, and test jacks. Use of the LCT is required for local operation, monitoring, control and setup. For details of system and provisioning setup, refer to Section IV NLite E LCT Manual. 1-1 GENERAL ROI-S05749 NEC NLite E MODEM(1) INTFC (1) MDP-150MB-1AA INDOOR UNIT INTFC (2) 0678 (H2930) DATE SER. No. WEIGHT: 4 kg (WITH OPTION) CTRL MODEM(2) −48 V 2.5A (WITH ODU & OPTION) NEC Corporation TOKYO JAPAN ! IF IN/OUT XIF IN XIF OUT TX RX XPIC RESET PWR ODU MD/ CBL SELV PULL ALM PWR OC-3 IN OC-3 OUT ALM OC-3 OUT ONLINE OC-3 IN NLite E NEO PROTECT (Blank) LCT NMS NE AUX/ALM SC IN/OUT EOW ONLINE XPIC CTRL MADE IN JAPAN CALL MAINT MEMORY IDU MMC IDU 1+0 ! IF IN/OUT XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV ! IF IN/OUT XIF IN XIF OUT PULL ALM PWR OC-3 OUT OC-3 IN ALM PWR OC-3 IN OC-3 OUT ONLINE PROTECT PULL LCT NMS NE AUX/ALM SC IN/OUT EOW CALL ONLINE XIF IN XIF OUT NLite E NEO MAINT MEMORY IDU MMC IDU 1+1 ! IF IN/OUT XIF IN XIF OUT TX RX XPIC RESET PWR ODU MD/ CBL SELV PULL ALM WS PWR 100M PORT 1 PORT 2 100M WS IN/OUT M.S XPIC CTRL PASOLINK NEO PROTECT (Blank) LCT NMS NE AUX/ALM SC IN/OUT EOW CALL MMC MAINT MEMORY IDU Equipped with LAN Interface for Main LAN (SONET) NEC NLite E 0678 TRP-( )G-1B OUTDOOR UNIT (NHG) SHIFT FREQUENCY (NWA-009034) MHz SUB BAND MHz TX FREQUENCY SERIAL No. CAUTION Non-ionizing radiation NEC NLite E MADE IN JAPAN -48V INPUT Power down IDU before disconnection or connection of cable. 0678 TRP-( )G-1B OUTDOOR UNIT (NHG) SHIFT FREQUENCY SERIAL No. DATE WEIGHT 3.5kg/ - 48V 0.5A NEC Corporation TOKYO JAPAN 1-2 2 pages TX HIGH/LOW (NWA-009034) MHz SUB BAND TX HIGH/LOW DATE WEIGHT 3.5kg/ - 48V 0.5A NEC Corporation TOKYO JAPAN CAUTION Non-ionizing radiation MADE IN JAPAN -48V INPUT Power down IDU before disconnection or connection of cable. ROI-S05749 OPERATING EQUIPMENT 2. OPERATING EQUIPMENT The indicators, switches, interface terminals and jacks for wiring with the associated equipment are described here. The IDU component modules listed in Table 2-1 are plugged-in from front of the IDU shelf as shown in Fig. 2-1. The component modules of the ODU shown in Fig. 2-2 are listed in Table 2-2. Note: Use shielded cables which are connected to the RJ-45 connectors to suppress interference from affecting the signal and to reduce electromagnetic radiation which may interfere with other signal cables. Note:Twist power cables (+)/(−) to suppress inductive interference signals. 2-1 OPERATING EQUIPMENT ROI-S05749 ! IF IN/OUT XIF IN XIF OUT XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV 4, or 5 PULL 5* PWR PROTECT LCT NMS NE AUX/ALM EOW CALL PASOLINK NEO MMC MAINT MEMORY IDU ! IF IN/OUT XIF IN XIF OUT SC IN/OUT XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV PULL PWR PROTECT LCT NMS NE AUX/ALM SC IN/OUT EOW CALL PASOLINK NEO MMC MAINT MEMORY IDU Table 2-1 IDU COMPOSITION H2930 MDP-150MB-1AA No. UNIT/MODULE NAME 1 + 1 system MODEM (X) (X) 32QAM/128QAM *1 MODEM − (X) 32QAM/128QAM *1 (√) − DC-DC CONV -20 to -60/+20 to +60 VDC *2 LAN INTFC (√) 4-Port-LAN (for SONET) *3 GbE INTFC (√) GbE (for SONET) OC-3 INTFC (√) OC-3 *3 for APS CTRL (X) Notes: 1. 2. *1 *2 *3 (X) always equipped. (√) optionally equipped. selectable in setting program. for expanding power supply range. for optional APS Fig. 2-1 IDU Composition 2-2 REMARKS Expandable 1 + 0 system ROI-S05749 NLite E RX LEV MON IFL FG 6 - 38 GHz ODU Table 2-2 ODU COMPOSITION TRP-( )G-1B 6 GHz 7 GHz) 8 GHz 10 GHz 11 GHz 18 GHz 23 GHz 26 GHz 38 GHz NWANWANWANWANWANWANWANWANWA009024( ) 009026( ) 009028( ) 009030( ) 009032( ) 009038( ) 009040( ) 009042( ) 009048( ) 1 RF CKT H2202( ) H2203( ) H2204( ) H2225( ) H2205( ) 2 IF CKT — — PS H2229( ) Note: Component modules are enclosed in the ODU case. 2-3 Fig. 2-2 ODU Composition H2230( ) H2231( ) H2234( ) OPERATING EQUIPMENT MODULE Name * OPERATING EQUIPMENT ROI-S05749 2.1 IDU Shelf Jack (IDU) Electrostatic Discharge (ESD) jack used to connect wrist strap band. Caution*:Engineers for maintenance of the equipment must take the necessary steps to avoid bit errors or cause damage to the modules due to electrostatic discharge. Wear a conductive wrist strap connected to the ground jack (G) on the front of the IDU to minimize static build-up during maintenance. 2-4 OPERATING EQUIPMENT ROI-S05749 2.2 CTRL CALL PROTECT NE NMS LCT PASOLINK NEO PROTECT LCT NMS NE AUX/ALM AUX/ALM SC IN/OUT SC IN/OUT EOW EOW MMC CALL MMC MAINT MEMORY IDU MAINT(amber) MEMORY(amber) IDU(red) The CTRL generates various control signals based upon LCT setup data and gathered operating status in the IDU and from the ODU, has SC, EOW, LAN, NE, EXT ALM, HK, Cluster ALM signals interface. By Connecting a PC, manual control, performance monitoring and system setup can be performed. Interface Signals (CTRL) AUX/ALM (D-Sub Female 44 pins) Input/Output Signal EOW: 1 CH Frequency: 0.3 to 3.4 kHz (1020 Hz (Test Tone)) Level: −6 dBm Impedance: 600 ohms ALM: ALM 6 outputs/6 HK Inputs/ 4 HK Control outputs, Cluster 4 Inputs/outputs Output: Relay contact Form-C Input: Photocoupler Bz 1,2 IN: Signalling control extension input. Call 1,2 OUT: Signalling control extension output. EOW: EOW headphone jack 2-5 OPERATING EQUIPMENT ROI-S05749 Interface Signals (CTRL) SC IN/OUT (D-Sub Female 44 pins) Input/Output Signal NE2: Network Element Level: RS-485 DSC (RS-232C): 2 CH Bit rate: 9600 bps Level: RS-232C DSC (V.11): 2 CH Bit rate: 64 Kbps Level: V.11 Impedance: 100 ohms NE (RJ-45): Network Element Level: 10 Base-T LCT (USB): Serial interface USB-B type connector with PC NMS (RJ-45): PNMS Level: 10 Base-T Indicators (CTRL) LED MAINT Indication Remarks Actively blinks: In progress of program data download. Maintenance mode can be selected by LCT, PNMT and Inactively blinks:Protect Mode for CTRL replacement in effect. PNMS “The maintenance Mode “ON” is selected”. MEMORY Memory Card (MMC) status. ON: Enable access to Memory Card OFF: Disable access to Memory Card Blinks: Accessing Memory Card IDU IDU Summary alarm. Check ALM LEDs on each module to find the cause and/or connect LCT to check the performance condition. Blinks: CPU or peripheral event occurred. 2-6 OPERATING EQUIPMENT ROI-S05749 Switch (CTRL) Switch Operating CALL Transmits EOW calling signal to sound the buzzer in the opposite station. PROTECT Prevent service interruption when the CTRL module is replaced. Remarks Accessing the Memory Card (MMC) is required to apply the function. User Interface Pin Assignment (CTRL) Terminal Description CTRL ALM/AUX IN/OUT (D-sub Female, 44 Pins) Service channel data input/output Pins 1 (+) and 16 (–) EOW input 1 Pins 2 (+) and 17 (–) EOW output 1 Pins 3 (+) and 18 (–) EOW input 2 Pins 4 (+) and 19 (–) EOW output 2 Pin 5 Ground Pins 25 (COM), 40 (NC) and 11 (NO) ⎯ RL1*1 Maintenance alarm output Between Pins 25 and 40 Closed Open Between Pins 25 and 11 Open Closed Pins 24 (COM), 39 (NC) and 10 (NO) ⎯ RL2*1 IDU CPU/PS1/PS2 alarm output Between Pins 24 and 39 Normal state Closed Alarm state Open Between Pins 24 and 10 Open Closed Pins 23 (COM), 38 (NC) and 9 (NO) ⎯ RL3 ODU1/ODU2 alarm output*2 Between Pins 23 and 38 Normal state Closed Alarm/Event state : Open Between Pins 23 and 9 Open Closed Normal state Alarm state 2-7 OPERATING EQUIPMENT ROI-S05749 User Interface Pin Assignment (CTRL) Terminal Description Pins 22 (COM), 37 (NC) and 8 (NO) ⎯ RL4 ODU CPU1/ODU CPU2/Cable Open alarm output*2 Between Between Pins 22 and 37 Pins 22 and 8 Normal state Closed Open Alarm/Event state : Open Closed Pins 21 (COM), 36 (NC) and 7 (NO) ⎯ RL5 IDU total alarm output*2 Between Pins 21 and 36 Closed Open Between Pins 21 and 7 Open Closed Pins 20 (COM), 35 (NC) and 6 (NO) ⎯ RL6 High BER1/High BER2 alarm output*2 Between Pins 20 and 35 Normal state Closed Alarm/Event state : Open Between Pins 20 and 6 Open Closed Pins 15 (+) and 14 (−) HK1 alarm input*3 Normal state Control/Event state : Open Closed HK2 alarm input*3 Normal state Control/Event state : Open Closed Normal state Alarm/Event state Pins 13 (+) and 12 (−) 2-8 Pins 29 (+) and 28 (−) HK3/Cluster4 alarm input*3 Normal state Open Control/Event state : Closed Pins 27 (+) and 26 (−) HK4/Cluster3 alarm input*3 Normal state Open Control/Event state : Closed Pins 44 (+) and 43 (−) HK5/Cluster2 alarm input*3 Normal state Open Control/Event state : Closed Pins 42 (+) and 41 (−) HK6/Cluster1 alarm input*3 Normal state Open Control/Event state : Closed Pin 30 Buzzer input 1 Pin 31 Call output 1 Pin 32 Buzzer input 2 Pin 33 Call output 2 OPERATING EQUIPMENT ROI-S05749 User Interface Pin Assignment (CTRL) Terminal Description CTRL SC IN/OUT (D-sub Female, 44 Pins) NE2/DSC Service channel data input/output Pins 1 (+) and 2 (–) NE2 TXD Pin 3 Ground Pins 4 (+) and 5 (–) V.11-1 TX data input Pins 6 (+) and 7 (–) V.11-1 RX data output Pins 8 (+) and 9 (–) V.11-2 TX data input Pins 10 (+) and 11 (–) V.11-2 RX data output Pins 12 and 13 (G) RS-232C-1 data input Pins 14 and 15 (G) RS-232C-2 data input Pin 16 NE2 RXD TERM Pins 17, 18 Ground Pins 19 (+) and 20 (–) V.11-1 TX clock input (co-dir.) or output (contra-dir.) *4 Pins 21 (+) and 22 (–) V.11-1 RX clock output Pins 23 (+) and 24 (–) V.11-2 TX clock input (co-dir.) or output (contra-dir.) 4* Pins 25 (+) and 26 (–) V.11-2 RX clock output Pins 27, 28, 29 Ground Pins 30 (+) and 31 (–) NE2 RXD Pin 32 Ground Pins 33 (+) and 34 (–) V.11-1 TX frame pulse input (co-dir.) or output (contra-dir.) *4 Pins 35 (+) and 36 (–) V.11-1 RX frame pulse output Pins 37 (+) and 38 (–) V.11-2 TX frame pulse input (co-dir.) or output (contra-dir.) *4 Pins 39 (+) and 40 (–) V.11-2 RX frame pulse output Pins 41 and 42 (G) RS-232C-1 data output Pins 43 and 44 (G) RS-232C-2 data output 2-9 OPERATING EQUIPMENT ROI-S05749 User Interface Pin Assignment (CTRL) Terminal LCT (USB connector type B) Description Local craft terminal (LCT) data input/output Pin 1 Vbus Pins 2 (–) and 3 (+) Pin 4 Ground NMS (RJ-45) PNMS data (10Base-T) input/output Pins 1 (+) and 2 (–) NMS TXD Pins 3 (+) and 6 (–) NMS RXD Pins 4, 5, 7 and 8 Not Connected NE (RJ-45) NE data (10Base-T) input/output Pins 1 (+) and 2 (–) NMS TXD Pins 3 (+) and 6 (–) NMS RXD Pins 4, 5, 7 and 8 Not Connected Notes: *1: RL1 (Maintenance) and RL2 (IDU CPU/PS1/PS2 ALM OUTUT) are fixed and can not be changed to other items. The relay contact is rated at 0.2 A. *2: These alarm items are assigned at the factory (default setting) and can be changed by the LCT as shown in Table 2-3 in Section 1 (Alarms may be selectively assigned to RL3 to RL6). *3: Photocoupler interface; resistance of open input terminal is more than 200 kilo ohms. Closed input terminal is less than 50 ohms. *4: V11 interface for the TX clock and frame pulse input/ output depend on co-/contra-directional mode setting in the LCT provisioning menu. 2-10 OPERATING EQUIPMENT ROI-S05749 EOW Connection When EOW signal is connected between two IDUs, perform wiring as follows. Terminal Station A EOW 4W S EOW 4W R Buzzer IN Call OUT Back -to- Back Station B 16 17 18 19 16 17 18 19 30 31 32 33 30 31 32 33 IDU Dir. B ALM/AUX IN/OUT (D-Sub, 44 Pins) EOW 4W S EOW 4W R 16 17 18 19 Buzzer IN Call OUT IDU Dir. A ALM/AUX IN/OUT (D-Sub, 44 Pins) EOW Extension 30 31 32 33 IDU Dir. C ALM/AUX IN/OUT (D-Sub, 44 Pins) 2-11 OPERATING EQUIPMENT ROI-S05749 2.3 MODEM TX (green) RX (green) XPIC RESET(amber) IF IN/OUT ! IF IN/OUT XIF IN XIF OUT XPIC CTRL TX RX XPIC RESET PWR(green) SELV ODU(red) MD/CBL(red) PWR ODU MD/ CBL SELV XPIC CTRL XIF OUT XIF IN PULL PWR PWR Caution: Do not apply to the equipment a voltage that varies sharply. The equipment operation may be impaired. Caution: Do not remove/connect the IF cable with the IDU power ON, Turn the IDU power OFF before connecting/disconnecting the IF cable, or equipment may cause damaged. Caution: Do not insert/extract the MODEM with the power ON, turn the IDU power OFF and remove all cables connected to the MODEM before insert/extract the MODEM, or MODEM may be damaged. Caution: The top surface of the IDU shelf above MODEM is hot in operation. The MODEM provides the 32QAM/128QAM Modulation/Demodulation for, 10/100Base T(x)/1000 Base T (LAN) or OC-3 (SONET) data transmission and following main functions. - Forward Error Correction using RS/Interleave - BER (High BER/Low BER) detection/indication/release for internal and external - Reducing ODU output signal distortion using BB Linearizer - Equalization using Transversal Equalizer - XPIC ODU synthesizer synchronization control - Interfered signal from opposite polarization cancellation (XPIC) - IDU/ODU power supply - System power on/off 2-12 OPERATING EQUIPMENT ROI-S05749 Interface Signals (MODEM) IF IN/OUT (TNC Female) TX Frequency: 340 MHz RX Frequency: 140 MHz Power supply: −48 V Impedance: 50 ohms Connecting IF Cable length: 5D-FB: less than 150 m 8D-FB: less than 300 m 10D-FB: less than 350 m G (Screw): Ground terminal (5 mm square cable (more than 2.5 mm diameter cable) (AWG#10) is recommended to apply for the frame ground. The proper press fix terminal tool shall be used.) SELV (Molex M5569-04A1, 4 pins) (DC IN) Input Voltage: XIF IN/XIF OUT (Receptacle IEC 169-13 (1.0/ 2.3)) −48 V DC (negative), + (positive, ground) Only used for XPIC system between two IDUs XIF IN: IF signal of opposite polarization input. (connect to XIF OUT of the other MODEM) XIF OUT: IF signal for opposite polarization output. (connect to XIF IN of the other MODEM) Frequency: 140 MHz Impedance: 75 ohms XPIC CTRL (D-Sub 15 pins, Serial Port) Only used for XPIC system between two IDUs (connect to XPIC CTRL of the other MODEM) Automatic/Remote XPIC reset control signal interface between mutual MODEM. 2-13 OPERATING EQUIPMENT ROI-S05749 Indicators (MODEM) LED PWR Indication Remarks The PWR switch of the MODEM is turned on. DC power is supplied to the ODU also. Transmit RF power of the ODU decreased approx. −3 dB from preadjusted ATPC minimum (MIN) level in provisioning. Check Metering using LCT for local and/or opposite site in Maintenance menu Receiver input level of the ODU falls below squelch level. APC loop of local oscillator in ODU is unlocked. ODU IF signal from the MODEM to ODU is lost. Blinks when IF cable is open circuit. Connected ODU is not matched with inventory. MD/CBL Blinks when IF cable is short circuit. TX (only 1+1) Selected status of ODU TX When TX mute control: LED Off RX (only 1+1) Selected status of MODEM RX output signal When RX SWO switched to opposite: LED Off XPIC RESET XPIC function is OFF condition Only XPIC configuration. Propagation condition deteriorated or XPIC is reset from LCT control. Switches (MODEM) Switch PWR 2-14 Operating IDU and ODU power On/Off switch. Remarks Refer to Start-up and Shut-down the Equipment in Maintenance Section OPERATING EQUIPMENT ROI-S05749 User Interface Pin Assignment (MODEM) Terminal Description SELV SELV (DC IN) (Molex M5569-04A1 Connector, 4 Pins) −48 V DC power input Note: Only −48 V (−40.5 to −57 V) is available. Pins 1 and 3 Ground Pins 2 and 4 −48 V IF IN/OUT TNC Jack (Female) * IF signal IN/OUT and PS OUT to the ODU XPIC CTRL (D-Sub Female, 15 pins) Used for interconnection configuration. Pins 1 (+) and 6 (–) XPIC SV TXD Pins 2 (+) and 7 (–) XPIC SV RXD Pin 3 Ground Pins 4 (+) and 9 (–) XPIC SEL IN Pins 5 (+) and 10 (–) XPIC SEL OUT Pins 8 (+) and 12 (–) XPIC RESET IN Pin 11 Ground Pins 13 (–) and 14 (+) XPIC RESET OUT Pin 15 Ground Note: * between IDUs in XPIC It is recommended that TNC (Male) L-angle connector for the 8D-FB IF cable is used to connect it to the IDU. When the N (Male) straight connector is attached to the 5D-FB or 10D-FB IF cable, use of the TNC (Male) - N (Female) (NJTNCP-LA) L-angle adapter is needed. 2-15 OPERATING EQUIPMENT ROI-S05749 2.4 OC-3 OPTICAL INTFC STM-1 (OPT) INTFC STM-1 OUT STM-1 IN ALM STM-1 OUT STM-1 IN ONLINE ALM (red) ONLINE(green) Caution: Do not insert/extract the OC-3 INTFC with the power ON. Turn OFF the PWR switch on the MODEM and remove all cables connected to the OC-3 INTFC before inserting/ extracting theOC-3 INTFC, or that INTFC may be damaged. The OC-3 INTFC provides an optical signal interface only. The module performs the following functions: - Coded Mark Inversion (CMI) to Non Return to Zero (NRZ) conversion - Optical to Electrical conversion - RSOH termination - Stuffing control - Hitless switching (for 1+1 configuration) - Performance monitoring (conforms to G.826/G.828) - Automatic Laser Shut Down (ALS) - Near End/Far End loopback 2-16 OPERATING EQUIPMENT ROI-S05749 Interface Signals (OC-3 INTFC) OC-3 IN/OUT LC Optical OC-3 Input/Output, G.957 Optical Type: G.957 Bit Rate: 155.520 Mbps Level: L-1.1: 0 to −8 dBm (TX)/−10 to −34 dBm (RX) S-1.1: −8 to −15 dBm (TX)/−8 to −28 dBm (RX) Code: NRZ Wavelength: 1310 nm Indicators (OC-3 INTFC) LED Indication Remarks LOSS of OC-3 from MUX is detected. Check MUX and wiring. Frame synchronization of input OC-3 signal from MUX is lost. Check MUX and wiring. BER (E-BER, DMR or MUX) is worse than preset value (10-3 to 10-5, selectable). ALM ONLINE BER (SD, DMR or MUX) is worse than preset value (10-5 to 10-9, selectable). Check RSL, Interference and TX power at opposite site when BER ALM occurs. Frame synchronization of input OC-3 signal from radio is lost. Check OC-3 transmission at the opposite site, ODU or MODEM in local. Mounting module inventory. Change LCT setting or other ( )INTFC module. is not matched with Online status of Working/Standby in APS: ON Offline status of Working/Standby in APS: OFF Online status of Working w/o APS: ON 2-17 OPERATING EQUIPMENT ROI-S05749 2.5 4P LAN INTFC 4P LAN PORT1 PORT2 ALM LED(red) PORT3 PORT4 ALM 100M PORT 1 PORT 2 100M 100M PORT 3 PORT4 100M 4P LAN INTFC The 4P LAN INTFC (optional) is installed into the Main-INTFC slot (Slot1) in the system configuration and it provides 4 Port LAN Fast Ethernet interfaces. The LAN interface is used 4 Port shared (P1-P4) mode, 2 Port (P1-P2/P3-P4) shared mode or separated (P1/P2/P3/P4) mode. Separated P1-P4 Shared (3) Dir-A (4) Dir-A (5) Dir-A P1 P2 P3 P4 2-18 P1 P2 P3 P4 P1 P2 P3 P4 P1 P2 P3 P4 Enabled Switching Disabled (1) Dir-A P1-P2 Shared P3-P4 Shared (2) Dir-A P1 P2 P3 P4 OPERATING EQUIPMENT ROI-S05749 User Interface Signals (4P LAN INTFC) LAN PORT1 PORT4 (RJ-45) to Input/Output Signal: LAN interface Port 1, Port 2, Port 3 and Port 4. Selectable 2 Mbps to 100 Mbps CH is assigned for LAN. 10/100Base-T(x) Auto-sensing or fixed Flow control: Full duplex or Half duplex Forwarding mode: Store-and-Forwarding Indicators (4P LAN INTFC) LED Indication 100M LAN signal is in 100BASE-TX mode. LINK LAN and associated equipment are linked and flashing under the exchanging the packet. COLLISION/ DUPLEX Input/Output LAN signal is in Full Duplex mode. Flashing when a collision condition occurs. ALM Remarks The module is extracted. Mount the module. Mounting module is not matched with inventory. Change LCT setting or other ( )INTFC module. LAN link failure occurs. Check LAN cable connection. Module failure occurs. Replace the module with a spare. 2-19 OPERATING EQUIPMENT ROI-S05749 2.6 GbE INTFC 1000BASE-SX INDICATOR 1000BASE-T 1000BASE-SX ALM OUT IN PORT The GbE INTFC (optional) provides 1000BASE-SX/1000BASE-T interface. The GbE INTFC is installed into the Main-INTFC slot (Slot1) instead of the OC-3 INTFC in the SONET (128 QAM) system configuration. The signal is connected either SFP (for 1000BASE-SX) or RJ-45 (for 1000MASE-T). These bytes (E1/F1/DCCr) are available between radio links. The RMON for LINE side is available but DMR side is unavailable. The maximum passed packet size is 9600 bytes. The GbE INTFC ia applicable together with the LAN INTFC. User Interface Signals (GbE INTFC) 1000BASE-SX: Gigabit Ether signal, Optical Interface 1000BASE-SX IN: 1000BASE-SX OUT: (SFP Optical Interface Connector) Ether signal Input Ether signal Output Speed & Duplex: 1000 Mbits Full Duplex/Auto Negotiation fixed Flow control: Flow control ON or OFF selectable Link Forwarding: Loss Disabled/Enabled selectable 1000BASE-T: Gigabit Ether signal, Electrical Interface 1000BASE-T Port: (RJ-45 Interface Connector) Ether signal Input/Output Speed & Duplex: 1000 Mbits Full Duplex/Auto Negotiation fixed Flow control: Flow control ON or OFF selectable Link Forwarding: 2-20 Loss Disabled/Enabled selectable OPERATING EQUIPMENT ROI-S05749 User Interface Pin Assignment (GbE INTFC) Terminal Description 1000BASE-SX (SFP Fiber connector) Multimode Fiber/LC Connector IN (Right side) 1000BASE-SX Input OUT (Left side) 1000BASE-SX Output 1000BASE-T (RJ-45, 8 pins) 1000BASE-T Input/Output (MDI/MDI-X) Pin 1 DATA-A+/ DATA-B+ Pin 2 DATA-A−/ DATA-B− Pin 3 DATA-B+/ DATA-A+ Pin 4 DATA-C+/ DATA-D+ Pin 5 DATA-C−/ DATA-D− Pin 6 DATA-B−/ DATA-A+ Pin 7 DATA-D+/ DATA-C+ Pin 8 DATA-D−/ DATA-C− Note: Cable connector: CAT5e/RJ-45 2-21 OPERATING EQUIPMENT ROI-S05749 Indicators (GbE INTFC) LED Indicator Indication Remarks Indicates which Port is applied to the signal interface. When the indicator is flashing slowly, the input signal is off in the corresponding interface port which is set to be used. When the indicator is flashing fast, the input/output signal is on in the corresponding interface port which is set to be used. When the indicator is lit steady, the signal is linked in the corresponding interface port which is set to be used. When the indicator is unlit, the corresponding interface which port is set to no use. The module is extracted. Mount the module. Mounting module is not matched with inventory. Change LCT setting or other ( )INTFC module. Module failure occurs. Replace the module with a spare. LOS from DMR is detected. ALM LOF from DMR is detected. Excessive-BER alarm condition from DMR occurs. Check IDU/ODU and radio link. SD from DMR is detected. 2-22 GbE output signal for fiber cable is interrupted. Replace the module with a spare. (SFP mode only) LAN link failure occurs. Check LAN cable connection. OPERATING EQUIPMENT ROI-S05749 2.7 DC-DC CONV DC-DC CONV − 43V STD − 43V PWR OUT ALM ALM OUT FUSE (250V/8AH) SELV PWR LED(green) FUSE (250V/8AH) PULL PWR PWR SELV Note: If the PWR LED is not lit though the PWR switch has set to ON, set the PWR switch to OFF, remove two fuses from the module and check the conduction of them. Caution: Do not apply to the equipment a voltage that varies sharply. The equipment operation may be impaired. Caution: Do not remove/connect the power supply cable with the PWR switch ON, Turn the PWR switch OFF before connecting/disconnecting the power supply cable IN or OUT, if not, module may be damaged. The DC-DC CONV (optional) converts 20 to 60 V or −20 to −60 V DC input to −43 V stable DC voltage. The module applies when the Nlite E + ODU is connected to the IDU. Interface Signals (DC-DC CONV) SELV (Molex M5569-04A1, 4 pins) (DC IN) Input Voltage: −20 to −60 V/+20 to +60 V DC −43V OUT (Molex M5569-02A1, 2 pins) (DC OUT) Output: G (Screw): −43 V/1.6A Ground terminal (5 mm square cable (more than 2.5 mm diameter cable) (AWG#10) is recommended to apply for the frame ground. The proper press fix terminal tool shall be used.) ALM: Power supply ALM signal output 2-23 OPERATING EQUIPMENT ROI-S05749 Indicators (DC-DC CONV) LED Indication PWR Remarks The PWR switch of the DC-DC CONV is turned on. Switches (DC-DC CONV) Switch Operating PWR IDU and ODU power on/off switch. Remarks Refer to Start-up and Shut-down the Equipment in Maintenance Section User Interface Pin Assignment (DC-DC CONV) Terminal Description SELV SELV (DC IN) (Molex M5569-04A1 Connector, 4 Pins) −20 to −60/20 to 60 V DC power input Pins 1 and 3 0 V /(or +20 to +60 V) Pins 2 and 4 −20 to −60 V/(or 0 V) −43V OUT (Molex M5569-02A1, 2 pins) (DC OUT) −43 V DC power output (connects to the SELV connector of the MODEM module using accessory cable) Pin 1 Ground Pin 2 −43 V ALM Power supply ALM signal output (D-Sub Female, 9 pins) 2-24 Pins 6 (COM), 1 (NC) and 2 (NO) PS and input voltage alarm output Between Pins 1 and 6 Normal state Closed Alarm state Open Pin 9 Ground Pins3,4,5,7,8 No connected Between Pins 6 and 2 Open Closed OPERATING EQUIPMENT ROI-S05749 2.8 ODU RF IN/OUT NLite E RX LEV MON IFL FG (FRONT VIEW) (REAR VIEW) FG (Frame Ground) RX LEV MON Antenna Direct Mounting Type IFL (IF IN/ OUT) RF IN/OUT RF IN/OUT (REAR VIEW) Coaxial Cable Type (6/7/8 GHz) (REAR VIEW) WG Type (6/7/8 GHz) The ODU receives 340 MHz IF signal from the IDU and converts it to an RF signal using a local signal generated by a synthesized local oscillator. This RF signal is then sent to the antenna through the BPF which limits the RF transmit signal dispersion. The TX output level is controlled to the specified from the IDU corresponded to the QPSK 32QAM or 128QAM modulation. The RF signal received from the antenna is amplified to the required level. Afterward the signal is converted into the 140 MHz IF signal by mixing with a local signal generated by a synthesized local oscillator. Then the 140 MHz IF signal is sent to the IDU through the IF cable. 2-25 OPERATING EQUIPMENT ROI-S05749 Interface Signals (ODU) IFL (N Female) TX Frequency 340 MHz RX Frequency: 140 MHz Power supply: −48 V Impedance: 50 ohms Connecting IF Cable length: 5D-FB: less than 150 m 8D-FB: less than 300 m 10D-FB: less than 350 m FG (Screw) Frame ground, connecting near by ground point. RF IN/OUT RF signal interface. N female connector for the 6/7/8 GHz ODU with coaxial cable connection. NEC proprietary flange for the 10 to 38 GHz ODU with antenna mounting (direct/OMT/HYB COMB/TX ATT). Waveguide connection flange; 6 GHz: PDR70 7/8 GHz: PDR84 10/11 GHz: PDR100 18/23 GHz: PBR220 38 GHz: PBR320 Monitoring Terminal (ODU) Terminal RX LEV MON: Operating Remarks Monitoring RX LEV in AGC voltage using the digital voltmeter or PASOLINK MONITOR unit * for antenna orientation. Use LCT to check the RX LEV in Maintenance. Note*:In order to measure exact performance of AGC V at the RX LEV MON, it is mandatory required to set Antenna Alignment Mode to ON as the AGC voltage indication is not guaranteed outside Antenna Alignment Mode. It is necessary to set to Antenna Alignment Mode every time monitor the RX level with the NLite E MONITOR unit. 2-26 SYSTEM SETUP ROI-S05749 3. SYSTEM SETUP This section provides system setup to make up proper system configuration. The setup is performed accessing to the LCT program using the PC. For the detail procedure, refer to Section IV Appendix LCT Operation Manual. 3.1 Equipment Setup The equipment setup menu decides system fundamental configuration. Note: For the details of setup item of the LAN PORT USAGE, refer to the LAN INTERFACE (10/100BASE T(X)) Application and Setting in Section IV. 3-1 SYSTEM SETUP ROI-S05749 Equipment Setup for SONET User Interface Redundancy Setting INTFC Main (WORK) INTFC SUB (PROT) XPIC Usage APS Function Modulation Scheme Transmission Capacity OC-3 GbE over OC-3 2Port LAN over OC-3 1+0(TERM) 1+1(Hot Standby TERM) 1+1(Twinpath TERM) OC-3(Optical) OC-3(Electrical) GbE over OC-3 2Port LAN over OC-3 Not Used OC-3 (Optical) WS WS/LAN Not Used Used (Main Master) Used (SUB Master) Unavailable Available 128QAM 156MB TX RF Frequency(No.1) [MHz] TX RF Frequency(No.2) [MHz] RX RF Frequency(No.1) [MHz] RX RF Frequency(No.2) [MHz] Frame ID(No.1) (Up to #32) Frame ID(No.2) (Up to #32) TX Power Control MTPC ATPC LAN Port Usage (Main) USED LAN Capacity(Main) 150Mbps LAN Port Usage (Main) P1=75MB/P2=75MB P1=100MB/P2=50MB Best Effort P1=100MB/P2=Not Used LAN Capacity(Main) 150Mbps LAN Port Usage (SUB) P1-2 Shared/1Port Only(WS) P1-2 Shared/1Port Only(SC) LAN Capacity(SUB) 64kbps 128kbps 192kbps 256kbps 2Mbps 3-2 When the “SONET GbE over OC-3” is selected for User Interface. (fixed) (fixed) (fixed when GbE INTFC is applied.) (fixed when GbE INTFC is applied.) (selectable when LAN INTFC is applied.) (fixed when LAN INTFC is applied.) SYSTEM SETUP ROI-S05749 Equipment Setup for SONET ---ODU FREQ INF--TX Start Frequency(No.1) [MHz] TX Stop Frequency(No.1) [MHz] Frequency Step(No.1) [MHz] Shift Frequency(No.1) [MHz] Upper/Lower(No.1) Sub Band(No.1) TX Start Frequency(No.2) [MHz] TX Stop Frequency(No.2) [MHz] Frequency Step(No.2) [MHz] Shift Frequency(No.2) [MHz] Upper/Lower(No.2) Sub Band(No.2) 3-3 SYSTEM SETUP ROI-S05749 3.2 Provisioning Setup The provisioning setup menu determines system fundamental functions. SONET Provisioning Setup Provisioning BER Threshold Setting BER Threshold Setting SC Assignment LAN Port Setting (For GbE INTFC) 3-4 High BER Threshold Low BER/E BER(DMR) SD(DMR) E BER(MUX) SD(MUX) High BER Threshold Low BER Threshold E-BER (DMR) SD (DMR) E-BER (MUX) SD (MUX) RS-232C-1/2 1E-3 1E-4 1E-5 1E-6 1E-7 1E-8 1E-9 1E-3 1E-4 1E-5 1E-6 1E-7 1E-8 1E-9 1E-3 1E-4 1E-5 1E-6 1E-7 1E-8 1E-9 Not Used SC1 SC2 SC3 SC4 E1 (MUX)F1(MUX)E1(DMR)F1(DMR) V11-1/2 Not Used SC1 SC2 SC3 SC4 E1 (MUX) F1(MUX) DCCr(MUX) E1 (DMR) F1(DMR) DCCR(DMR) F1(DMR) V-11-1/2 Direction Setting LAN Port Setting Switching Function Port Media Type Speed & Duplex Flow Control Link Loss Forwarding Co-directional Disable Contra-directional Enable SFP RJ-45 AUTONEG (1000MB Full Duplex).) Off On Disabled Enabled SYSTEM SETUP ROI-S05749 LAN Port Setting (For LAN INTFC) INTFC (Main) Setting Switching Function Clock Souce Setting Port1 Port Usage Speed & Duplex Flow Control Collision Report Port2 Port Usage Speed & Duplex LAN Port Setting (For LAN INTFC) Flow Control Collision Report Link Loss Forwarding INTFC (SUB) Setting Switching Function Port1 Port Usage Speed & Duplex Flow Control Collision Report Link Loss Forwarding Internal Clock DMR Internal -> Clock Not Used Used AUTONEG (Auto-MDI/MDX) 10M-Half (MDI) 10M-Full (MDI) 100M-Half (MDI) 100M-Full (MDI) 10M-Half (MDIX) 10M-Full (MDIX) 100M-Half (MDIX) 100M-Full (MDIX) Off On Not Report Report Not Used Used AUTONEG (Auto-MDI/MDX) 10M-Half (MDI) 10M-Full (MDI) 100M-Half (MDI) 100M-Full (MDI) 10M-Half (MDIX) 10M-Full (MDIX) 100M-Half (MDIX) 100M-Full (MDIX) Off On Not Report Report Disabled Enabled Disabled Enabled Not Used Used AUTONEG (Auto-MDI/MDX) 10M-Half (MDI) 10M-Full (MDI) 100M-Half (MDI) 100M-Full (MDI) 10M-Half (MDIX) 10M-Full (MDIX) 100M-Half (MDIX) 100M-Full (MDIX) Off On Not Report Report Disabled Enabled Port2 (Items for Port 2 are same as the Port1) 3-5 SYSTEM SETUP OC-3 Setting ALS TX Power Control Condition for TX/RX SW Condition for APS Relay Setting TCN Threshold(15min) ROI-S05749 MS-AIS Generation ALS Function ALS Interval ATPC Threshold Level(No.1/2) [dBm] Additional ATT(No.1/2 [dB] ATPC Range(MAX)(No.1/2) [dB] ATPC Range(MIN)(No.1/2) [dB] ATPC Power Mode(No.1/2) MTPC TX Power (No.1/2) [dBm] ATPC Threshold Level(No.1/2) [dBm] Additional ATT(No.1/2) [dB] TX SW Priority RX SW Priority RX SW Maintenance Mode RX SW Condition-Early Warning APS Maintenance Mode APS Condition-SF(PROT) APS Condition-Signal Degrade-SD(B1) Lock in Usage Lock in Count [times] Lock in Detect Time [min] Lock in Hold Time [hours] ALM output for RL1 to RL6 HK output for RL3 to RL6 Cluster1 to Cluster4 input Cluster1 to Cluster4 output DMR/ OCR/RCVR MUX OCR/RCVR TCN Threshold(1day) DMR/ OCR/RCVR MUX OCR/RCVR PMON Select RX Level TCN Threshold [dBm] SES Activation Condition EOW2 External Setting Alarm Correlation Capacity Others 3-6 Disabled Enabled Disabled Enabled 60sec 180sec 300sec HOLD Max Non-Priority Non-Priority Manual Included EW Manual Priority High Included SD Not Used Out HK Disabled Out OFS UAS ES SES BBE SEP OFS UAS ES SES BBE SEP 30[%] Normal Off MIN Priority No.1 Priority No.1 Forced Excluded EW Forced Priority Low Excluded SD Used Enabled 15[%] Invert On SYSTEM SETUP ROI-S05749 3.3 Events and Performance The alarm and status condition are based upon equipment setup and provisioning setup, therefore indication items vary depending on the those setup. The summarized event and performance monitoring that are displayed on the LCT PC are listed in the following table. For the detailed items, refer to Section IV Appendix LCT OPERATION MANUAL. 3-7 SYSTEM SETUP ROI-S05749 Event List SONET Alarm Status ODU ODU TX Power TX Input RX Level APC ODU CPU Mute Status LO REF TX SW Status RX SW Status : only XPIC configuration : only 1+1 configuration : only 1+1 configuration MODEM MODEM MODEM Unequipped LOF Route ID High BER Low BER Early Warning MOD DEM Input Voltage Power Supply IF Cable Short Linearizer Status Linearizer Fail Cable EQL XIF XCTRL XPIC Status XREF ATPC Power Mode : only XPIC configuration CTRL CTRL Module MMC Mount APS SW Fail APS Online Status APS Lock in Status XCTRL XCTRL Mode Mismatch UAE OC-3(1)/UAE(MUX) OC-3(1)/UAE(DMR) 3-8 : only APS configuration : only APS configuration : only APS configuration : only XPIC configuration : only XPIC configuration SYSTEM SETUP ROI-S05749 Event List SONET INTFC (Main) Unequipped Type Mismatch OC-3(1) LOS (MUX) OC-3(1) LOS (DMR) OC-3(1) LOF (MUX) OC-3(1) LOF (DMR) OC-3(1) Output Control OC-3(1) E-BER (MUX) OC-3(1) E-BER (DMR) OC-3(1) SD (MUX) OC-3(1) SD (DMR) OC-3(1) In-Phase OC-3(1) TF INTFC (Main) Unequipped Type Mismatch Module LAN Link Link Loss Forwarding Speed & Duplex LOS (DMR) LOF (DMR) E-BER (DMR) SD DMR Inphase TF GbE INTFC 3-9 SYSTEM SETUP ROI-S05749 Event List SONET INTFC (Sub) INTFC(2) Unequipped OC-3(2) LOS (MUX) OC-3(2) E-BER (MUX) OC-3(2) E-BER (DMR) OC-3(2) SD (MUX) OC-3(2) SD (DMR) OC-3(2) Output Control OC-3(2) In-Phase OC-3(2) LOS (DMR) OC-3(2) LOF (MUX) OC-3(2) LOF (DMR) OC-3(2) TF Unequipped Type Mismatch Module LAN Link LAN Collision Link Loss Forwarding Speed & Duplex TCN-RX LEV TCN-RX LEV-15min TCN-RX LEV-1day 3-10 OPT INTFC applies APS *1 *1 When LAN Port *1 *1 SYSTEM SETUP ROI-S05749 Event List SONET 15min 1 day TCN-OFS-15min Total TCN-UAS-15min Total TCN-ES-15min Total TCN-SES-15min Total TCN-BBE-15min Total TCN-SEP-15min Total TCN-OFS-15min(MUX) TCN-UAS-15min(MUX) TCN-ES-15min(MUX) TCN-SES-15min(MUX) TCN-BBE-15min(MUX) TCN-SEP-15min(MUX) TCN-OFS-15min(MUX)(P) TCN-UAS-15min(MUX)(P) TCN-ES-15min(MUX)(P) TCN-SES-15min(MUX)(P) TCN-BBE-15min(MUX)(P) TCN-SEP-15min(MUX)(P) TCN-OFS-1day Total TCN-UAS-1day Total TCN-ES-1day Total TCN-SES-1day Total TCN-BBE-1day Total TCN-SEP-1day Total TCN-OFS-1day(MUX) TCN-UAS-1day(MUX) TCN-ES-1day(MUX) TCN-SES-1day(MUX) TCN-BBE-1day(MUX) TCN-SEP-1day(MUX) TCN-OFS-1day(MUX)(P) TCN-UAS-1day(MUX)(P) TCN-ES-1day(MUX)(P) TCN-SES-1day(MUX)(P) TCN-BBE-1day(MUX)(P) TCN-SEP-1day(MUX)(P) only APS configuration only APS configuration 3-11 SYSTEM SETUP ROI-S05749 Event List SONET PMON(History) RX Level DMR (W) DMR (W) MUX (W) MUX (W) RX Level(15min) RX Level(1day) (1day) Status OFS SEP BBE ES SES UAS (15min) Status OFS SEP BBE ES SES UAS (day) Status OFS SEP BBE ES SES UAS (15min) Status OFS SEP BBE ES SES RMON(Line)(15min) only for LAN Status RX UNICAST RX BROADCAST RX MULTICAST RX PAUSE RX CEC ERR RX ALIGNMENT ERR RX SYMBOL ERR RX UNDERSIZE RX FRAGMENTS RX Pkts 64 RX Pkts 65 to 127 RX Pkts 128 to 255 RX Pkts 256 to 511 3-12 SYSTEM SETUP ROI-S05749 Event List SONET RX Pkts 512 to 1023 RX Pkts 1024 to 1536 TX JABBERS TX UNICAST TX BROADCAST TX MULTICAST TX PAUSE TX COLLISION Notes : *1 When the LAN/WS INTFC is provided, status of each LAN PORT is displayed as follows. Status of LAN PORT Link Sub PORT1 Sub PORT1 Link Link Collision Normal Normal LLF Normal Normal Speed & Duplex 100M-Full (MDIX) 100M-Full (MDIX) Notes:For the GbE INTFC, there are distinctions for the following functions from the 10BASE-T/100BASE-Tx 1. RX Undersize: Unavailable. 2. RX Fragments: Unavailable. 3. RX Symbol Errors: For SFP: Available For RJ-45: Unavailable (un-counting, only "0" is indicated.) 4. TX Multicast PKts (Including number of the TX pause packets.) 5. RX Multicast PKts (Including number of the RX pause packets.) 6. Countable packet size for the following items shown in right side of the table and reading must be taken place as follows. (The indication will not be taken placed.) Indication 15 RX Pkts 1024-1536 16 RX Pkts 1537-MAX Reading RX Pkts 1024-1518 RX Pkts 1519-MAX 7. The RX Alignments Error is counted as an RX CRC ERR. 3-13 SYSTEM SETUP ROI-S05749 3.4 Control The control condition is based upon equipment setup and provisioning setup, therefore control items vary depending on the those setup. The control items that are displayed on the LCT PC are listed in the following table. the control operation can be performed in Maintenance “ON”. 3-14 SYSTEM SETUP ROI-S05749 Control List (SONET) Control Maintenance TX SW Manual Control RX SW Manual Control RX SWMaintenance Mode ATPC Manual Control(No.1) ATPC Manual Control(No.2) TX Mute Control(No.1) TX Mute Control(No.2) CW Control(No.1) CW Control(No.2) APS Manual Control (Auto/Working/Protection) APS Maintenance Mode IF Loopback(No.1) IF Loopback(No.2) Main Loopback (Near End) Main Loopback (Near End) INTFC (1) Main Loopback (Near End) INTFC (2) Main Loopback (Far End) Linearizer Control(No.1) Linearizer Control(No.2) ALS Restart XPIC Control Local(No.1) XPIC Control Local(No.2) XPIC Control Remote(No.1) XPIC Control Remote(No.2) Offline Maintenance DADE Adjust RF SUB Band Select(No.1) RF SUB Band Select(No.2) RF Shift Frequency Setting(No.1) RF Shift Frequency Setting(No.2) Antenna Alignment Mode(No.1) Antenna Alignment Mode(No.2) *1 *1 *1 *1 *1 : Only APS configuration : Only APS configuration *1 : Only APS configuration : Only APS configuration *1 : Only Optical INTFC : Only XPIC configuration : Only XPIC configuration : Only XPIC configuration : Only XPIC configuration *1 *1 *1 Note *1: only for 1+1 Configuration. 3-15 SYSTEM SETUP ROI-S05749 3.5 Setup Description The following describes to select suitable functions for the system operation by the provisioning setup. 3.5.1 Automatic Laser Shutdown Control (OPT INTFC) (SONET) The OC-3 INTFC (only for OPT) is provided with the Automatic Laser Shutdown (ALS) function that can be enabled or disabled. If the ALS function is enabled, the laser output is periodically turned ON and OFF when the optical cable carrying the OC-3 signal is disconnected inadvertently, or intentionally during maintenance. When the ALS function is disabled, the laser output is always ON even if the optical cable is disconnected. Fig. 3-1 shows a block diagram of the ALS function. If a fault occurs at point A and the absence of the optical input signal in the RX 2 lasts for 550 ±50 msec (OC-3 LOS alarm condition), the optical signal bound for the RX 1 (MUX equipment) from the TX 2 (OPT INTFC module) is interrupted by a control signal generated inside the OPT INTFC module. The MUX equipment detects the loss of signal at RX1 and the ALS function in the MUX will, subsequently, turn off the laser output of TX1. When the fault at point A is cleared the system can be restored by controlling the laser output of TX2 through one of the following modes: • Automatic control • Manual restart (2 sec.) control • Manual restart (90 sec.) control (a) Automatic Control When 60, 180 or 300 sec.(selectable) have elapsed after the optical signal entering RX 2 is cut off, the IDU emits laser signal from TX 2 to RX 1 for 2 sec. This would then cause the laser output of TX1 to turn on. If, at this time, the fault at point A has been cleared, the ALS function will be released and the operation will return to normal. (b) Manual Restart (2 sec.) Control Upon receiving a command signal for manual restart from the LCT or the PASOLINK network management terminal (PNMT) while the optical input signal to the RX 2 is off, the IDU emits the laser signal from the TX 2 to the RX 1 for 2 ±0.25 sec. This would then cause the laser output of TX1 to turn on. If, at this time, the fault at point A has been cleared, the ALS function will be released and the operation will return to normal (if not it returns to automatic condition). 3-16 SYSTEM SETUP ROI-S05749 (c) Manual Restart (90 sec.) Control Upon receiving a command signal for manual restart for test from the LCT or the PNMT while the optical input signal to the RX 2 is off, the IDU emits the laser signal from the TX 2 to the RX 1 for 90 ±10 sec. This would then cause the laser output of TX1 to turn on. If, at this time, the fault at point A has been recovered, the ALS function will be released and the operation will return to normal (if not it returns to automatic condition). MUX EQUIPMENT TX1 CTRL OPT INTFC RX2 O/E RLOS TX2 550 ± 50 ms TIMER CLEAR ALS CONT ENABLE/DISABLE 90±10S TX ON TIMER 2±0.25S TX ON TIMER 60/180/ 300 sec. DELAY CONT RX1 2S TX ON TIMER O/E SB/DATA BUS DATA BUS LCT or PNMT Fig. 3-1 ALS System Functional Block Diagram 3-17 SYSTEM SETUP ROI-S05749 3.5.2 Automatic Protection Switching (APS) (OPT INTFC Optional APS Configuration) (SONET) (a) Line Protection The Automatic Protection Switching (APS) provides for unidirectional line protection against optical cable interface failures. It is performed by detected alarm condition or remote control signal. Module Failure SW CTRL LOS/LOF/BER DET Working OPT IN OC-3 (OPT) INTFC only 1+1 SW MODEM OPT OUT Remote CTRL SW CTRL SW Protection OPT IN OPT OUT OC-3 (OPT) INTFC MODEM LOS/LOF/BER DET Module Failure Fig. 3-2 OPT APS System The OC-3 (OPT) INTFC monitors the OPT line input signal interface condition and when an alarm condition occurs in the optical cable or optical interface module, APS is activated. Also the APS is activated when remote control signal is received. Uni-directional APS is performed only in the receiving section of the local side when a failure or signal degradation of the received signal is detected in one direction. Fig. 3-3 shows APS switching mode. 3-18 SYSTEM SETUP ROI-S05749 SW CTRL ASSOCIATED EQUIPMENT NLite E Received OPT failure (1) (Work) WORKING WORKING (Prot) PROTECTION PROTECTION OC-3 (OPT) INTFC (No.1) OC-3 (OPT) INTFC (No.2) WORKING WORKING (Work) (2) OC-3 (OPT) INTFC (No.1) PROTECTION PROTECTION (Prot) OC-3 (OPT) INTFC (No.2) SW CTRL ASSOCIATED EQUIPMENT (1) (Work) Received OPT failure WORKING WORKING NLite E OC-3 (OPT) INTFC (No.1) (Prot) PROTECTION PROTECTION OC-3 (OPT) INTFC (No.2) (Work) WORKING WORKING OC-3 (OPT) INTFC (No.1) (Prot) PROTECTION PROTECTION OC-3 (OPT) INTFC (No.2) (2) Uni-directional Mode Line Protection Note: ON LINE OFF LINE Fig. 3-3 Line Protection 3-19 SYSTEM SETUP ROI-S05749 (b) APS Function Setup The APS switchover is performed with the following order of priority of two (2) modes. (1) When “APS Condition-SF” is lower priority (default). • UNEQUIP > LKI*1 > FSW > SF > SD*2 > MSW (2) When “APS Condition-SF” is higher priority. • UNEQUIP > LKI*1 > SF(P) > FSW > SF(W) > SD*2 > MSW Notes: *1 Excluding when the Lock in Usage is set Not Used. *2: Excluding when the APS Condition-SD(B1) is set to Excluded SD. UNEQUIP:Unequipped redundant OC-3 INTFC (OPT). LKI:Lock in (see following descriptions Lock in for detail) FSW:Forced Control (see following descriptions when APS Maintenance Mode is set to Forced) SF: Signal Fail (see following descriptions of APS Condition-SF(PROT) SF(P); Signal Fail of Protection side SF(W); Signal Fail of Working side SD; Signal Degrade (see following descriptions APS Condition-SD(B1) for detail) MSW;Manual control (see following descriptions when APS Maintenance Mode is set to Manual) 3-20 SYSTEM SETUP ROI-S05749 LCT MENU Alarm/Status Equipment Setup Inventory AUX I/O Maintenance Provisioning BER Threshold Setting SC Assignment OC-3 Setting TX Power Control Condition for TX/RX SW Condition for APS Relay Setting TCN Threshold (15min) TCN Threshold (1day) PMON Select Others Metering PMON(Current) PMON(History) ---Condition for APS--APS Maintenance Mode Manual APS Condition-SF(PROT) Priority High APS Condition-SD(B1) Included SD Lock in Usage Not Used Lock in Detect Count [times] Lock in Detect Time [min] Lock in Hold Time [hours]) Range 10 24 Forced Priority Low Excluded SD Used 1 to 255 1 to 60 1 to 48 • APS Maintenance Mode This is a setup to give priority to manual control operation in maintenance. Manual: Give priority to alarm events in maintenance operation. In this mode, manual control disables the operation under alarm condition. Forced: Give priority to forced control in maintenance operation. In this mode, manual control enables the operation under alarm condition and the alarmed side can be selected. Caution: When the APS Maintenance Mode is set to “Forced” in provisioning, APS manual control can select either Working or Protection line though one is alarmed. Then, take care switching to avoid traffic interruption. • APS Condition-SF(PROT): This is a setup to give higher priority to switchover by SF in Protection side. Priority High: This setup gives highly priority to SF of Protection side (installed in INTFC Slot2) for switchover control condition. Since the setup gives priority higher than the Forced Control, the ONLINE is maintained in Main side (installed in INTFC Slot1) under occurrence of SF condition of Protection side. 3-21 SYSTEM SETUP ROI-S05749 • APS Condition-SD(B1) This is a setup that it includes the SD or excludes SD for the switchover control condition. When including it, the switchover is performed when SD reaches the threshold value which is set in BER Threshold/SD (MUX) in provisioning. Include SD: Including SD for switchover condition Exclude SD: Excluding SD for switchover condition • Lock in The function is used to pause the switchover activation for a period of time when in the switchover of frequent occurrence. The following setting is needed to be used for it. Lock in Count: Setup for the Lock in threshold value of the switchover number of times. (setting range: 1 to 255 times) Lock in Detect time: Setup for the watching interval of counting number of times for Lock in. (setting range: 1 to 60 minutes) Lock in Hold time: Setup for the duration of pause of switchover in the Lock in condition. (setting range: 1 to 48 hours) The Lock in status can be observed on the Alarm/Status of LCT display. The Lock in condition may be released after passing the Lock in Hold time or the change of setting. The following is an example in default value. • Lock in Count: 4 • Lock in Detect time: 10 • Lock in Hold time: 24 This sets into the Lock in condition when the switchover is activated more than 4 times within 10 minutes interval of watching number of times. The switchover activation pauses during 24 hours after set in the Lock in condition. The Lock in condition will be released after passing of 48 hours and it sets into normal mode. When it will be manually released that under the Lock in condition, perform resetting by changing parameter value or changing the setting condition to “Lock in Usage Not Used”. 3-22 SYSTEM SETUP ROI-S05749 3.5.3 Automatic Transmitter Power Control The automatic transmit power control (ATPC) function automatically varies the TX output power according to path conditions. In the SHF and EHF band, fading exerts heavy influences on propagation, causing the receive signal level at the opposite station to vary. The ATPC function operates by controlling the transmit output power of the opposite station according to the variation of the received signal level at the local station. ATPC provides the following advantages: • Improvement in up fading characteristics • Improvement in residual BER characteristics • Reduction of interference to intra system • Reduction of interference to inter system Note: In the XPIC configuration, ATMC/MTPC setup and action control in the Sub Master station are applied from the Main Master station. A functional block diagram of the ATPC operation is shown in Fig. 3-4. ATPC improves the BER characteristics under adverse changes in climatic conditions and reduces the possibility of interference. To implement ATPC, the received level (RX LEV) is detected by the Receiver (RX) in the ODU and passed to the CPU in the CTRL module. The CPU then determines whether the transmit output power needs to be controlled. This is based on the transmit output power and the minimum and maximum values of the output control range (ATPC range). ATPC is relevant for the receiving threshold level that were previously specified using the LCT or PNMT (as ATPC Threshold Level). A control signal (POWER CTRL), whose function is to maintain the received RX signal level (RSL) by decreasing or increasing the TX output power of the opposite station, is generated by the CTRL module through the MD Unit. This control signal is based on the result of comparison between the current receiver input level and the preset receiving threshold level. This control signal is sent to the opposite station to control its transmit output power. At the opposite station, this control signal is detected by the CTRL module. The TR Unit, in accordance with this control signal, produces a control that will either raise, lower or maintain the current TX output power. 3-23 SYSTEM SETUP ROI-S05749 TRANSMITTING STATION RECEIVING STATION MODEM TX POWER CONT REMOTE MODEM RX RX IN LEV CTRL CTRL REMOTE ATPC CTRL ATPC CTRL MODEM RX TX MODEM Fig. 3-4 ATPC, Functional BLock Diagram Example of ATPC setting. Where ATPC MAXIMUM PWR of ATPC Range is set to 0 dB, ATPC MINIMUM PWR is set to -10 dB and RX Threshold to -55 dBm. In this case, if RX level is lower than -55 dBm, monitor/control is performed with the interval of 8 msec. RX level is monitored in 1 dB step, and TX output is controlled in 1 dB step. However, a fixed hysteresis of 5 dB referred to the RX Threshold is implemented for ATPC operation. Example: If RX Threshold is set to -55 dBm, no output control is made unless the RX level goes below -55 dBm or goes above -50 dBm, so that the receive level is maintained within -55 to -50 dBm by ATPC. -50 dBm 5 dB (ATPC HYSTERESIS) RX LEVEL -55 dBm (RX THRESHOLD LEVEL) 3-24 SYSTEM SETUP ROI-S05749 Using MTPC-ATPC The ATPC Control System of the PASOLINK transmits the information on the receiving level to the opposite station and controls the transmission level of its local station in accordance with the receiving level of the opposite station. Transmission level control can be used not only for setting the same operation (ATPC-ATPC) between local station and opposite station but also for operation in combination of stations with different operations (MTPC-ATPC, ATPC-MTPC). The station set in MTPC mode is not controlled by the information from opposite station but is fixed in its transmitting output level. Even if the station is set in the MTPC mode, the opposite station is likely to be set in the ATPC mode. Therefore, setting the RX Threshold (ATPC Threshold level) is required for controlling the transmission level of the opposite station. Between the stations that are respectively set in the MTPC mode, however, the setting is disabled. The following is an example of operation between stations set in MTPCATPC mode. STATION A PASOLINK ODU MTPC (RX Threshold: −50 dBm) STATION B PASOLINK ODU ATPC The transmitting level of station B is controlled so that the receiving level of station A in the above figure reaches the RX Threshold set level (−50 dBm) set in station A. This method is used in station A for reducing the level of interference to other route. As station A is set in the MTPC mode, the transmitting level is kept unchanged. An example of using MTPC-ATPC is shown below. As shown in the figure, in the master station communicating with many substations, waves gather from substations possibly causing interferences. Therefore, substations must be set in the ATPC mode to minimize the diffraction (interference) to other routes while reducing the receiving levels from individual substations to the minimum. In substations, there is little possibility of occurring interferences; therefore, the master station is set in the MTPC mode to permit transmission at a constant level. 3-25 SYSTEM SETUP ROI-S05749 (MTPC) MASTER STATION (ATPC) SUBSTATION 1 (ATPC) SUBSTATION 2 (B) (A) (C) (ATPC) SUBSTATION 5 (ATPC) SUBSTATION 3 (ATPC) SUBSTATION 4 : Diffraction to other route. (A),(B) (C) : RX received level down. A constant transmit output power in both MTPC and ATPC is maintained using the ALC function which is provided in the RF CKT module. The ALC circuit detect the transmit output power using a diode to obtain a DC voltage proportional to the transmit power. The gain of the RF amplifier is controlled inversely with this detected DC voltage to maintain the transmit output power within the specified limits. When the ATPC malfunction occurs, transmitter output power is maintained at the following level according to the ATPC mode. The ATPC mode is set in provisioning using LCT. Hold:Maintain the TX output level at the current level, when the ATPC malfunction occurs. MAX:Maintain the TX output level at ATPC maximum level, when the ATPC malfunction occurs. MIN:Maintain the TX output level at ATPC minimum level, when the ATPC malfunction occurs. 3-26 SYSTEM SETUP ROI-S05749 3.5.4Loopback Control The loopback function is provided for checking the system quality during maintenance and/or to quickly isolate a fault location on the SONET configuration. The control is performed by the LCT, the PNMT or the PNMS. Provided here is the control of the: • Near-End loopback is performed at the OC-3 INTFC module. • Far-End loopback is performed at the OC-3 INTFC module. • IF loopback (IF-LB) is performed at the MODEM module ((c) in Fig. 3-5) for IF signal. Notes: 1. During the IF loopback is in execution, monitoring of the opposite and the subsequent stations are disabled on the PNMS and PNMT. 2. Loopback control will interrupt the radio link condition. 3. The IF LOOPBACK and the RX SW is not operated interlock. The RX SW switching is necessary to select the same CH with IF LOOPBACK in 1+1 configuration. OPPOSITE STATION OWN STATION IDU OC-3/E1/E3 CODE DATA CONV IN MUX MOD (a) OC-3/E1/E3 CODE DATA CONV OUT DEMUX TX RX CTRL IDU DEM DEM RX CODE CONV DEMUX OC-3/E1/E3 DATA OUT (b) (c) TX MODEM ( )INTFC LCT/ PNMT ODU ODU MOD MODEM MUX CODE CONV OC-3/E1/E3 DATA IN ( )INTFC Note: Reverse direction is the same as above. Fig. 3-5 Loopback Location 3.5.5 Link Loss Forwarding Control (LAN) Link Loss Forwarding (LLF) control provides two kinds of functions for 10/100BASE-T interface. One is to automatically stop the output from the 3-27 SYSTEM SETUP ROI-S05749 LAN port to alert the equipment connected with the LAN port when the system has been disconnected by the fault in the radio section. The other is to transmit the information for cutting the link interconnected with the LAN port in the opposite station when the link between the LAN port and equipment is faulty. This function can be selected by setting “Provisioning” on LCT to “Enable” or “Disable”. AUTO: Output Stop Radio Fault FAULT HUB LAN LAN HUB 3.5.6 MS-AIS Generation (SONET) When any fault occurs in the NLite E equipment, or when OC-3 input signal disappears, or when any fault occurs in radio section, The function of MS-AIS Generation causes the OC-3 output signal from the NLite E equipment to be stopped and/or non-frame signal (all “1”) to be output, to detect the fault in the MUX equipment of the opposite station. MUX DATA IN NLite E NLite E DATA OUT MUX RADIO SECTION This function can be selected by setting “Provisioning” on LCT to “Enable” or “Disable”. Normally, this function is set to “Enable”. If this function is set to “Disable”, the function of MS-AIS Generation is stopped. 3-28 SYSTEM SETUP ROI-S05749 For example, at the station A, when the NLite E equipment detects the OC3 input Loss Of Signal (LOS) and/or Loss Of Frame (LOF), the information is transmitted to the station B by using RFCOH. When the station B detects the information, NLite E equipment stops the OC-3 output signal. Similarly, it is the same even if a receiving input level down or loss of radio frame (LOF) appear in station B. STATION A STATION B NLite E OC-3 INPUT OC-3 INTFC INPUT LOSS NLite E MODEM RFCOH MUX MODEM ODU ODU FSYNC RFCOH RLOS/RLOF OC-3 OUTPUT CONTROL Station A Event OC-3 OUTPUT OC-3 LOF LOF LOS LOF OC-3 INTFC RFCOH DEMUX Station B LCT OC-3 OUTPUT LED LCT LED OC-3 Output Control OC-3 Input Loss at Station A IDU ALM MAIN INTFC LOS ⎯ Under Execution Shutdown * (or all “1”) OC-3 Loss of Frame at Station A IDU ALM MAIN INTFC LOF ⎯ Under Execution Shutdown * (or all “1”) RX Level Down ⎯ N/A ODU ALM Under Execution Shutdown * (or all “1”) Loss of Radio Frame at Station B ⎯ N/A IDU ALM Under Execution Shutdown * (or all “1”) BER Degrade (≤1E-4) at Station B ⎯ N/A IDU ALM Normal N/A Notes:1. * Optical interface: Shutdown Electrical interface: all “1” 2. When the MS-AIS Generation is “Enable”, status indication of MS-AIS Generation on LCT is not indicated. 3-29 SYSTEM SETUP ROI-S05749 3.5.7 Cross Polarization Interference Canceller (XPIC) Reset Control For the Cross Polarization Interference Canceller (XPIC) to function properly, signals for both Main Master and Sub Master sides must be received normally. For this reason, when either signal is in abnormal condition, the XPIC RESET function provides a way for turning off the XPIC operation. Local/Remote XPIC reset can be controlled separately to the Main Master and Sub Master. Control OPPOSITE STATION (Sub Master) LOCAL STATION (Main Master) Main Master CH Remote XPIC reset V-pol OC-3 CH1 ODU IDU XIF OC-3 CH2 IDU coincidence V-pol Dual Pol. f1 f2 f1 f2 OMT ODU H-pol Note : ODU IDU OC-3 CH1 Local/Remote XPIC reset V-pol XIF OMT REMOTE Local/Remote XPIC reset H-pol coincidence Remote XPIC reset H-pol V-pol H-pol ODU IDU OC-3 CH2 Sub Master CH Feeder Connection for Dual Pole Feed Antenna. Fig. 3-6 XPIC Reset Control The LOCAL RESET and/or REMOTE RESET control is performed to the channel which is working online when the system is following conditions. • When the MODEM or ODU is replaced. • Frame Synchronization is lost (FASYNC) at the MODEM module in the Co-pol. channel. • At the MODEM module in the Co-pol. channel, IF signal from X-pol. channel is lost (XIF alarm). • The system is controlled in IF loopback (IF-LB) condition with the LCT, PNMS or PNMT. • The XPIC RESET control is executed from the LCT, PNMS or PNMT. • The XPIC RESET control is applied from the MODEM module in the X-pol. channel. • The XREF or LO REF alarm condition occurs. Note: The SD system can not be applied for the XPIC configuration. 3-30 SYSTEM SETUP ROI-S05749 3.5.8 Network Management (Optional) The Network Management System (NMS) configuration is shown in Fig. 3-7. The PASOLINK network management system (PNMS) is connected to the NMS (LAN) connector of the IDU located at the designated maintenance center while the PASOLINK network management terminal (PNMT) is connected to the LCT USB connector on the IDU of remote stations. The PNMT/PNMS provides monitoring and control of the actual microwave link status and its associated Nlite E equipment. Status information form and control signals to remote stations are transmitted using RFCOH. For detailed information, refer to the related PNMS or PNMT manual. NLite E NLite E NMS (LAN) CONNECTOR PNMS LCT CONNECTOR PNMT PNMS : PASOLINK Network Management System PNMT : PASOLINK Network Management Terminal Fig. 3-7 Network Management System 3-31 SYSTEM SETUP ROI-S05749 3.5.9 Functionality Classification The functionality of the NLite E is defined by optional system parameters, interface card and transmission capacities as listed in the following categories. The functionality is found in the Software Key in the LCT Inventory menu. Functionality Classification of the NLite E Capacity and Redundancy Bit Rate LAN Interface XPIC Functionary 1+0 System 1+1 System Fixed Available Available 1. 10 MB 1. 10 MB Free Unavailable Unavailable 2. 20 MB 2. 20 MB 3. 40 MB 3. 40 MB 4. 80 MB 4. 80 MB 5. 100 MB 5. 100 MB 6. 156 MB 6. 156 MB Optional System, Interface Card and Transmission Capacity System and Transmission Capacity 1+0 3-32 1+1 OC-3 Opt S1.1 156MB 156MB OC-3 Opt L1.1 156MB 156MB 2P LAN 156MB 156MB GbE 156MB 156MB SYSTEM SETUP ROI-S05749 3.6 Protection Switching Protection switching is provided in the 1+1 Twin-path and the HS systems. 3.6.1 1 + 1 Twin-path System Protection switching in this system is performed by a hitless switch (HL SW) on the ( )INTFC module of the IDU at the receiving end. When both the No. 1 and No. 2 channels are in normal operating condition, the OC-3 data streams from the associated MUX equipment are sent to the receiving end through the No. 1 and No. 2 channels. At the receiving end, the output data streams of the No. 1 and No. 2 channels MODEM enter the HL SW. The data signal selected by HL SW is fed to associated MUX equipment. At the receiving end, when the low bit error alarm (LOW BER ALM) is detected in the MODEM of the No. 1 channel, the alarm signal is sent to the switch control logic circuit on the CTRL module. The switch control logic circuit send the HL SW control signal to the ( ) INTFC module. Then, the HL SW selects the data signal from No.2 channel. The switching condition is shown on the RX1 and RX2 STATUS indicators on the IDU. 3.6.2 Hot-standby System Protection switching in this system is performed by the TX switches* on the No. 1 and No. 2 channel ODUs at the transmitting end and by the HL SW** on the ( ) INTFC module of the IDU at the receiving end. Note: 1. * Transmit switching is actually accomplished by muting the output of either No.1 or No.2 channel ODU, using a control signal from the IDU. When both the No. 1 and No. 2 channels are in normal operating condition, the OC-3 data signal from the associated MUX equipment are sent to the No. 1 and No. 2 channel ODUs through the No. 1 and No. 2 channel IDUs. Here, either of the No. 1 or No. 2 channel signal is selected at the TX switch on the ODU and fed to the receiving end. At the receiving end, the output data signal of the No. 1 and No. 2 channels MODEM enter the HL SW on the ( ) INTFC module. The data signal selected by HL SW is fed to associated MUX equipment. 3-33 SYSTEM SETUP ROI-S05749 When the modulator alarm is detected in the MODEM or when the TX IF input alarm, TX power alarm or APC alarm is detected in the ODU, the alarm signal is sent to the switch control logic circuit on the CTRL module. The switch control logic circuit produces a TX switch control signal for selecting the ODU that is in the normal condition. When the ODU receives the TX switching control signal, the output of the ODU that is currently active (on-line) is muted and the output of the other ODU is un-muted. The switching condition is shown on the TX1 and TX2 STAUS indicators on the IDU. At the receiving end, when the low bit error alarm (LOW BER ALM) is detected in the MODEM of the No. 1 channel, the alarm signal is sent to the switch control logic circuit on the CTRL module. The switch control logic circuit send the HL SW control signal to the ( )INTFC module. Then, the HL SW selects the data signal from No.2 channel. The switching condition is shown on the RX1 and RX2 STATUS indicators on the IDU. 3.6.3 Switchover Control The following explains the protection switching function in the 1+1 Twinpath and HS system. (a) TX Switching TX switching in HS system is accomplished by muting the TX output power of either No.1 or No.2 channel ODU. Two mode of TX switch controls are provided: automatic switching that is initiated by detection of a failure in the transmit section of the IDU or ODU, and manual switching is performed by using the LCT. TX switching, either manually or automatically, may cause a momentary interruption of the traffic. TX switching have the following operational mode: • Switching Mode: 1. Manual : Applied in Maintenance mode. 2. Auto: Normal operating mode. TX SW Setup in provisioning has following features: • Switching Priority: 1. Non Priority: Selecting non revertive mode. 2. Priority No.1: This mode is applied to select No.1 when both No.1 and No.2 are normally operating. 3-34 SYSTEM SETUP ROI-S05749 (b) RX Switch RX switching in 1+1 Twin-path/HS system is performed by the HL SW on the ( ) INTFC module. Two types of RX switch controls are provided: automatic switching that is initiated by the quality deterioration of the received signal and manual switching that is initiated by the operator using the LCT. The switching mode and switching priority for automatic and manual switching are identical to those of TX switching. However, the switching priority is only valid under automatic switching control. This is because automatic switching is implemented by hardware logic and manual switching is implemented by software logic. That is, automatic switching and manual switching are completely independent and separate operations. Thus, when the operator reverts to automatic switching after performing manual switching, the channel will be re-selected by the switch control logic circuit. • Switching Mode: 1. Manual : Applied in Maintenance mode. 2. Auto: Normal operating mode. RX SW Setup in provisioning has following features: • Switching Priority: 1. Non Priority: Selecting non revertive mode. 2. Priority No.1: This mode is applied to select No.1 when both No.1 and No.2 are normally operating. • RX SW Maintenance Mode: 1. Manual mode, this disables the RX SW manual control when either No. 1 or No. 2 RX route is in alarm status. 2. Forced mode, this enables the RX SW manual control though either or both No. 1 and No. 2 RX routes are in alarm status. Caution: When the RX SW mode is set to “Forced” in provisioning, RX SW manual control can select either No. 1 or No. 2 RX route though one is alarmed. Then, take care switching to avoid traffic interruption. 3-35 SYSTEM SETUP ROI-S05749 • RX SW Condition-Early Warning 1. Included Early Warning, this switch over the RX SW at less than 1E-9. 2. Excluded Early Warning, this switch over the RX SW at Low BER setting values 1E-6, 1E-7, 1E-8 or 1E-9. (default value is 1E-7) • RX Switching Condition Cross Reset (only XPIC 1+1 configuration): 1. Included Cross Reset, this switch over the RX SW when XPIC reset control is acted. 2. Excluded Cross Reset, this does not switch over the RX SW though XPIC reset control is acted. 3-36 SAFETY INFORMATION ROI-S05747-052E August, 2007 SAFETY INFORMATION This safety instruction is prepared to protect accident resulting personal injury or death and also physical damage of the equipment during maintenance or installation. To avoid hazardous conditions, read this Instruction Manual thoroughly before equipment operation. The signal words (Danger, Warning and Caution) are used in the Instruction manual as follows: GENERAL SAFETY DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates an imminently hazardous situation which, if not avoided, could result in serious injury or physical damage. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or physical damage. It is also said to alert against inappropriate practice. LABELS Caution and Warning labels attached to the IDU and ODU as follows: -1- SAFETY INFORMATION ROI-S05747 -48V OUTPUT Power down IDU before disconnection or connection of cable. WARNING Turn off power of IDU before disconnecting cable. Do not disconnect I/F cable between the IDU and the ODU in operation condition, to avoid damaging the IDU and the ODU. The −48 V DC power is superimposed on the center conductor of the I/F cable between the IDU and the ODU. Connecting a test equipment directly to this terminal may damage it and touching the coaxial cable core may cause electrical shock. -48V OUTPUT Power down IDU before disconnection or connection of cable. -48V INPUT Power down IDU before disconnection or connection of cable. ! CAUTION HOT SURFACE Avoid contact. Be careful that top surface of the IDU is hot. ! CAUTION HOT SURFACE Avoid contact. CAUTION Non-ionizing radiation CLASS 1 LASER PRODUCT Caution that the Non-ionizing radiation from the equipment may effect on health. In a system using the OPT INTFC module, do not stare at the laser beam or look at it directly with optical instruments. Otherwise, it may hurt your eyes (Does not apply to PDH). The mark on the electrical and electronic products only applies to the current European Union Member States. -2- WARNING ROI-S05747 WARNING WARNING The –48 V DC power is superimposed on the center conductor of the coaxial cable between the IDU and the ODU. Connecting a test set equipment directly to this terminal may damage it and touching the coaxial cable core may cause electrical shock. WARNING Do not touch the I/F cable jack core before turning off the power switch. If touching the coaxial cable core may cause electrical shock. WARNING In a system using the OPT INTFC module, do not stare nor use optical instruments to look at the laser beam directly as this may cause eye damage. (Class 1 Laser Product). WARNING This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. -3- CAUTION ROI-S05747 CAUTION CAUTION While the power supply is ON, do not connect/disconnect the power supply connector. Otherwise, the DC-DC CONV may break down. CAUTION Locate the ODU within the area protected by lightning rod. To avoid surge currents caused by lightning circulating in the equipment earth system, connect the equipment earth system (frame ground) to ground of the lightning rod at ground level. CAUTION Interrupt operation and turn off the power switch on the IDU, if in the event of an emergency situation with appearance such as smoking, burning smell, and strange sound. Continuation of operation may cause burning or resulting in electric shock. As there is risk, do not attempt to repair. CAUTION Introduction of spilling liquid, piece of metal, smoke, corrosive gas or dust into the equipment, or approach of birds or animals may cause burning or break-down. CAUTION Do not perform overhaul, modification or repairing of the equipment. As it may cause burning or resulting in electric shock. -4- NOTICE (PLACING) ROI-S05747 NOTICE (PLACING) 1. When the ODU is installed in the indoor, as the ODU generates Non-ionizing radiation and it may cause health effect, then, it is required to take adequate measures. 2. Do not block the vents of the equipment. It may cause break down due to heating up of inner equipment in stuffy condition. Ensure to follow the set up and usage rules as follows. Do not set up the equipment on the carpet, heating floor or bare concrete. Do not cover or wrap the equipment with table cloth, lace, rubber or plastic material. Do not set up the equipment in the bookshelves or rocker or in a stuffy place. Do not put anything like books or paper on and against the equipment. 3. The equipment must be installed in correct place. Do not install turning sideways or slanting. If not properly installed, it may cause break down due to rise of inner temperature. 4. Do not install the equipment in the following locations. If installed, it may cause harmful influence for the equipment. The equipment must be installed and maintained in a clean, and dry place where temperature and humidity remain stable, non-condensing into dew and within the ranges specified by the manufacturer. 5. Because of the equipment is an indoor type, do not install the equipment in the location where it could be caused harm influence by salt-air, sand-dust, sulphuric acid gas etc.. If the equipment will be installed necessarily in such location, the following must be heeded. (a) Construction of the Equipment Room Install the equipment in the airtight room or shelter where it could not be suffered by external influence mentioned above. -5- NOTICE (PLACING) ROI-S05747 (b) Environmental Temperature Impact for the Equipment In the airtight room, it may be caused rising in temperature with the heat generation of the equipment. Furnish an air-conditioner for industrial use in accordance with the situation. Do not apply air directly from the air-conditioner to the equipment. When the equipment is located in face of the air from the air-conditioner, it could be condensed into dew by temperature variation. (c) 6. -66 Pages In the case of using at marine and coastal areas (within 3 km from the seaside), it is necessary to make measures against the damage from salt water. For measures against the damage from salt water to an ODU, request them to NEC. The place of installation is restricted to Telecommunication Center and similar environment. ROI-S05755-054E April, 2007 ABBREVIATIONS ABBREVIATIONS The following abbreviations are used in the manual for the NLite E equipment. ABBREVIATION DESCRIPTION AIS Alarm Indication Signal ALM Alarm ALS Automatic Laser Shutdown ANT Antenna APC Automatic Phase Control APS Automatic Protection System ASYNC Asynchronization ATPC Automatic Transmitting Power Control ATT Attenuator AUX Auxiliary BBE Background Block Error BER Bit Error Rate BNC Bayonet Navy Connector BPF Band Pass Filter CAS Channel Associated Signaling CBL Cable CD Compact Disk CH Channel CKT Circuit CLK Clock CMI Coded Mark Inversion COM Common COMB Combiner CONN Connection CONT Control -1- ABBREVIATIONS ROI-S05755 ABBREVIATION DESCRIPTION CONV Converter CPU Central Processing Unit CTRL Control CW Carrier Wave DADE Differential Absolute Delay Equalizer DC Direct Current DCCr Data Communication Channel in RSOH DCK Drop Clock DDT Drop Data DEM Demodulator DFP Drop Frame Pulse DMR Digital Microwave Radio DSC Digital Service Channel Electrical E/O Electrical/Optical E-BER Excessive-Bit Error Rate EMC Electro Magnetic Compatibility EOW Engineering Orderwire EP Earthing Point EQL Equalizer ERR Error ES Errored Seconds EXT External -2- ROI-S05755 ABBREVIATIONS ABBREVIATION DESCRIPTION FAS Frame Alignment Signal FEC Forward Error Correction FG Frame Ground FIL Filter FPGA Field Programable Gate Array FREQ Frequency F/W Firmware Ground GND Ground HD Hard Disk HK House Keeping ICK Insert Clock ID Identification IDT Insert Data IDU Indoor Unit IE Internet Explorer IEEE Institute of Electrical and Electronic Engineers IF Intermediate Frequency I/F Inter Facility IFL Inter Facility Link IN Input INTFC Interface I/O Input/Output IP Internet Protocol ITU International Telecommunication Union -3- ABBREVIATIONS ROI-S05755 ABBREVIATION DESCRIPTION LAN Local Area Network LB Loop Back LCD Liquid Crystal Display LCT Local Craft Terminal LED Light Emitting Diode LLF Link Loss Forwarding LEV Level LO Local LOF Loss of Frame LOS Loss of Signal -4- MAC Media Access Control MAINT Maintenance MD Modulator Demodulator MDI Media Dependent Interface MDIX Media Dependent Interface with Crossover MFAS Multi Frame Alignment Signal MIX Mixer MII Media Independent Interface Mib Management Information Base MLC Multi-Level Coding MMC Memory Card MOD Modulator MODEM Modulator-Demodulator MON Monitor MPX Multiplexer MS-AIS Multiplexer Section Alarm Indication Signal MTPC Manual Transmitter Power Control MUX Multiplexing Equipment ROI-S05755 ABBREVIATIONS ABBREVIATION DESCRIPTION NC Normal Closed NE Network Element NMS Network Management System NO Normal Open NORM Normal NRZ Nonreturn to Zero Optical O/E Optical/Electrical ODU Outdoor Unit OFS Out of Frame Second OH Overhead OMT Orthogonal Mode Transducer OPT Optical OS Operating System OUT Output OW Orderwire Protection PC Personal Computer PDH Plesiochronous Digital Hierarchy PH Phase PKG Package PM PASOLINK Management PMON Performance Monitor PNMS PASOLINK Network Management System PNMT PASOLINK Network Management Terminal PROT Protection PS Power Supply PWR Power -5- ABBREVIATIONS ROI-S05755 ABBREVIATION DESCRIPTION QAM Quadrature Amplitude Modulation QPSK Quadrature Phase Shift Keying RAM Random Access Memory REC Rectifier LO REF Local Reference Frequency RF Radio Frequency RFCOH Radio Frame Complementary Overhead RL Relay RMON Remote Network Monitoring ROM Read Only Memory RS Reed Solomon RSOH Regenerator Section Overhead RST Regenerator Section Termination RSL Received Signal Level RX Receive SC Service Channel SD Signal Degrade SDH Synchronous Digital Hierarchy SELV Safety Extra Low Voltage SES Severely Errored Seconds SEP Separation SEP Severely Errored Period SOH Section Overhead SONET Synchronous Optical Network STM Synchronous Transport Module SV Supervisory SW Switch SYNC Synchronizer SYNTH Synthesizer -6- ROI-S05755 ABBREVIATIONS ABBREVIATION DESCRIPTION SYS System TCN Threshold Crossing Notification TRP Transmitter-Receiver Equipment TX Transmit UAE Unavailable Event UAS Unavailable Second URL Uniform Resource Locator USB Universal Serial Bus VF Voice Frequency V/H Vertical/Horizontal VOL Volume Vo-p Volt zero (0) to Peak Working Web World Wide Web WG Waveguide XC Cross Connect XIF IFof Cross Polarization XPIC Cross Polarization Interference Canceller XPD Cross Polarization Discrimination -7- ABBREVIATIONS ROI-S05755 (This page is intentionally left blank.) -88 pages APPENDIX FCC STATEMENT INFORMATION .................................. 1-1 1-1 1.0 FCC INFORMATION The device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received. This device must be professionally installed. MADE IN JAPAN The NLite E 5.8 GHz radios will be used for fixed Point to Point applications. The NLite L radio utilizes a parabolic antenna that requires professional installers for path alignment. The maximum RF transmit power of the NLite E 5.8 GHz radios is less than 0.3162 watts (+25 dbm). Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The peak RF transmit power of the NLite E 5.8 GHz radios is less than 1.0 watts (+30 dbm). This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to the part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Safety Information 1-2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2009:02:20 08:42:45-05:00 Creator : FrameMaker 8.0 Modify Date : 2009:02:20 08:42:55-05:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2009:02:20 08:42:55-05:00 Creator Tool : FrameMaker 8.0 Format : application/pdf Document ID : uuid:b8c3be01-68e9-4bd5-865e-1f08d4bdc10f Instance ID : uuid:f87e38b8-556b-4649-adab-7901fac700f2 Producer : Acrobat Distiller 6.0 (Windows) Page Count : 138EXIF Metadata provided by EXIF.tools