User Manual Part 2
INSTALLATION ROI-S05750 2.1 Packages Each unpacked component of the [ ] GHz [ ] MB digital radio system must be checked as shown below. CONTENS LIST 2-2 DRAWING NO. IDU and ODU Fig. 2-2 Mounting Bracket Fig. 2-3 Installation Kit Fig. 2-4 and Fig. 2-5 INSTALLATION ROI-S05750 NLite E (*1) RX LEV MON IFL FG ! IF IN/OUT XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV PULL ALM PWR OC-3 OUT OC-3 IN ALM OC-3 OUT ONLINE OC-3 IN PROTECT NLite E NEO MAINT MEMORY IDU (Blank) LCT No. NMS NE AUX/ALM SC IN/OUT EOW CALL MMC DESCRIPTION TRP-( )G-1B / TRP-52G-5A (ODU) MDP-150MB-1AA (IDU) O-Ring (Attached to the waveguide type ODU) Power Connector (Molex Housing M5557-4R (x1ea) and Socket Contact (5556TL (x4 each)) Cylindrical Fuse ((RKS-F91000-0107) (6.3A) (x1ea) *2) XPIC CTRL Cable (×1) (apply for XPIC configuration only) X-IF Coaxial Cable (×2) (apply for XPIC configuration only) Note: *1 *2 ONLINE XIF IN XIF OUT One more ODU and MODEM module are provided for HS/Twinpath configuration. One spare fuse is provided in the MODEM module. Fig. 2-2 Contents of Basic Unit Package 2-3 INSTALLATION ROI-S05750 H3042K I/O BOARD SER No. DATE WEIGHT kg MADE IN JAPAN NWA-011060-001 DC-DC CONV UNIT WEIGHT 2.5kg SER No. DATE 1+0 System STD Input : 20 60V 3.4A 1.0A Output : − 43V 1.3A 1+1 System STD Input : 20 60V 3.4A 1.0A×2 Output : − 43V 1.3A×2 NEC Corporation TOKYO JAPAN MADE IN JAPAN No. − 43V STD OUT PWR ALM SELV FUSE (250V/8AH) − 43V PULL PWR STD OUT FUSE (250V/8AH) DESCRIPTION H3042K I/O BOARD Bracket NWA-011060-001 DC-DC CONV UNIT (see Fig. 2-7 for details) Fig. 2-3 Contents of Optional Unit Package 2-4 PWR ALM SELV PULL PWR INSTALLATION ROI-S05750 (Supplied with antenna) No. DESCRIPTION Pole Mounting Bracket for Coaxial Cable Connection Type (6/7/8 GHz) Pole Mounting Bracket for Wave Guide connection Type Pole Mounting Bracket for Antenna direct Mounting Type Fig. 2-4 Pole Mounting Bracket 2-5 IFL LUG XPIC CTRL TX RX XPIC RESET (BLANK) XIF IN XIF OUT ! IF IN/OUT IN PORT 1 WS 100M PORT PORT 2 PWR ODU MD/ CBL SELV PWR PULL LCT NMS NE AUX/ALM 100M PORT 3 PORT4 100M ALM MS WS IN/OUT ALM SC IN/OUT EOW CALL PROTECT OC-3 OUT OC-3 INTFC (OPT) OC-3 IN LAN INTFC (SONE D-SUB CONNECTOR/(MALE) OC-3 OUT MMC MAINT MEMORY IDU NLite E ALM OC-3 IN ONLINE ALM LC (P) CONNECTOR LC (P) CONNECTOR IEC 169-13 (P) CONNECTOR IEC 169-13 (P) CONNECTOR ALM D-SUB CONNECTOR/(MALE) D-SUB CONNECTOR/(MALE) MODULAR CONNECTOR/(MALE) MODULAR CONNECTOR/(MALE) USB CONNECTOR/(MALE) ALM 100M D-SUB CONNECTOR/(MALE) PORT 2 MODULAR CONNECTOR/(MALE) WS IN/OUT PORT 1 Note: It is recommended that TNC (Male) L-angle connector for the 8D-FB IF cable is used to connect it to the IDU. When the N (Male) straight connector is attached to the 5D-FB or 10DFB IF cable, use of the TNC (Male) - N (Female) (NJ-TNCP-LA) L-angle adapter is needed. Note: The LAN/WS INTFC which is put a [M.S] label may be installed into either Slot1 or Slot2 on the IDU in the SONET system. LUG OUT 1000BASE-SX 100M 100M OC-3 INTFC 1053J8A (P) Accessory cable (150M) 1053J8A (P) Accessory cable D-SUB Accessory cable/(MALE) MOLEX CONNECTOR/ (FEMALE) TNC-P CONNECTOR (MALE) GbE INTFC (SONET) LC (P) CONNECTOR LC (P) CONNECTOR MODULAR CONNECTOR/(MALE) MODULAR CONNECTOR/(MALE) LAN INTFC (SONET) N-P CONNECTOR (MALE) FG 2M IN/OUT MODULAR CONNECTOR/(MALE) MODULAR CONNECTOR/(MALE) Fig. 2-5 Installation Kit Packing List of IDU and ODU for 1+0 System IDU RX LEV MON No.1 ODU 2-6 4P LAN INTFC MODULAR CONNECTOR/(MALE) MODULAR CONNECTOR/(MALE) D-SUB CONNECTOR/(MALE) INSTALLATION ROI-S05750 NLite E INSTALLATION ROI-S05750 D-SUB CONNECTOR/ (FEMALE) MOLEX CONNECTOR/ (FEMALE) DC-DC CONV UNIT (Optional) MOLEX CONNECTOR/ (FEMALE) D-SUB CONNECTOR/ (FEMALE) NWA-011060-001 DC-DC CONV UNIT WEIGHT 2.5kg SER No. DATE 1+0 System STD Input : 20 60V 3.4A 1.0A Output : − 43V 1.3A 1+1 System STD Input : 20 60V 3.4A 1.0A×2 Output : − 43V 1.3A×2 NEC Corporation TOKYO JAPAN MADE IN JAPAN − 43V ! IF IN/OUT XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV XPIC CTRL TX RX XPIC RESET PWR ODU MD/ CBL SELV ! IF IN/OUT XIF IN XIF OUT ALM PULL PULL FUSE (250V/8AH) SELV − 43V PULL PWR OUT STD PWR ALM PULL PWR SELV FUSE (250V/8AH) ALM ALM PWR OC-3 IN OC-3 IN OC-3 OUT OC-3 OUT XIF IN XIF OUT PWR OUT STD NLite E PROTECT PWR LCT NMS AUX/ALM NE MAINT MEMORY IDU SC IN/OUT EOW CALL MMC RESERVE HOT SURFACE Avoid contact. ! CAUTION RESERVE No. DESCRIPTION NWA-011060-001 DC-DC CONV UNIT H3040 DC-DC CONV Power Cable (NWM-005773-001, attached to the DC-DC CONV) Power Connector (Molex Housing M5557-4R (x1ea) and Socket Contact (5556TL (x4 each)) Cylindrical Fuse ((CBE-006255-001) (8A) (x2 ea) *2) Note: *1 *2 One more ODU and MODEM module are provided for HS/Twinpath configuration. Two spare fuses are provided in the DC-DC CONV module. Fig. 2-6 Installation Kit Packing List of DC-DC CONV UNIT for 1+1 System 2-7 INSTALLATION ROI-S05750 2.2 Unpacking of IDU and ODU The unpacking procedures for the IDU and ODU are shown in following chart. • IDU : Chart 2-1 • ODU : Chart 2-2 Note: When conveying the IDU or ODU to another place, the original packing should be used to avoid damage. Chart 2-1 Unpacking Method for IDU Step Procedure Cut the p.p. tape at top of the carton (1 to 3). Then open the carton, 2-8 INSTALLATION ROI-S05750 Chart 2-1 (Cont’d) Step Procedure Take out the accessories, IDU carton and cushioning materials, CUSHIONING MATERIAL CARTON (ACCESSORIES) CARTON (IDU) CUSHIONING MATERIAL (IDU) 2-9 INSTALLATION ROI-S05750 Chart 2-1 (Cont’d) Step Procedure Remove the cushioning materials from the carton (IDU), Take out the IDU wrapped with antistatic bag from the carton, ANTISTATIC BAG IDU CARTON (IDU) 2-10 Take out the IDU from the antistatic bag, Inspect the IDU. INSTALLATION ROI-S05750 Chart 2-2 Unpacking Method for ODU Step Procedure Take off the hook of a cover as shown below. Then, open the top cover, HOOK 2-11 INSTALLATION ROI-S05750 Chart 2-2 (Cont’d) Step Procedure Take out cushioning material, buffer material and poly sheet, TOP PAD POLY SHEET ODU 2-12 Take out the ODU from carton, Inspect the ODU. INSTALLATION ROI-S05750 2.3 IDU Mounting The installation procedure for the IDU explains in Chart 2-3. The IDU should be installed in the radio station. Chart 2-3 Mounting Methods of the IDU Step Procedure Change the two brackets to desired position on the IDU, if necessary, FRONT POSITION CENTER POSITION SIDE VIEW 1+0/1+1 SYSTEM 2-13 INSTALLATION ROI-S05750 Chart 2-3 (Cont’d) Step Procedure Align the IDU to the mounting position on the 19-inch rack, SPRING WASHER SCREW FLAT WASHER SPRING WASHER SCREW FLAT WASHER Fix each side of the IDU to the 19-inch rack with the two screws, IDU 2-14 INSTALLATION ROI-S05750 Chart 2-3 (Cont’d) Step Procedure To mount the IDU in a 19-inch rack, take a space more than 200 mm to the rear section and space for one unit to the top and bottom. At least one rack unit * More than 200 mm * At least one rack unit * WALL Note: * Normal setting for free space. When free space is closed within one rack unit, keep the environment temperature is lower than +40°C. This Page Not Used 2-15 INSTALLATION ROI-S05750 2.4 DC-DC CONV UNIT Mounting (Optional) The installation procedure for the DC-DC CONV UNIT (optional) explains in Chart 2-5. The DC-DC CONV UNIT(optional) should be installed in the radio station. Chart 2-4 Mounting Methods of the DC-DC CONV UNIT Step Procedure Fix the DC-DC CONV UNIT to the 19-inch rack using the two screws. DC-DC CONV UNIT SPRING WASHER RACK SCREW FLAT WASHER SPRING WASHER IDU FLAT WASHER SCREW Note: * Space 0.5 rack unit in the upper or lower DC-DC CONV UNIT. upper screw hole RACK At least 0.5 rack unit * IDU lower screw hole 2-16 DC-DC CONV UNIT DC-DC CONV UNIT 2U 2U 0.5U DC-DC CONV UNIT INSTALLATION ROI-S05750 2.6 NLite E SONET OC-3ODU Mounting The procedures for mounting and demounting the ODU are described here. There are two types of mounting for the antenna direct mounting type and waveguide connecting type. The ODU should be installed in the radio station. The tools for installation are listed in Table 2-1. Table 2-1 Tools TOOLS Wrench or Monkey wrench Screwdriver Torque Wrench Caution 1. How to use small and large O-rings are shown in following table. Two (small and large) O-rings are attached in 18 to 38 GHz band Andrew/RFS direct mount antenna. 11/13/15 GHz band antenna does not have small O-ring (Small O-ring is not used for Andrew/RFS direct mount antenna). If the small O-ring is used for ODU direct mount installation, a gap may occur between ODU and antenna for RF interface. Therefore it may happen transmit or receive level down. Caution 2. Do not apply silicon grease at O-ring. SYSTEM 1+0 1+1 ATTACHENENT POSITION OF O-RING (BETWEEN:) O-RING REMARKS SMALL SIZE LARGE SIZE ANT ⎯ ODU Not used Used Antenna direct mounting ANT ⎯ WG/ODU (18-38 GHz BAND) Used Not used Waveguide connection ANT ⎯ HYB Not used Used Antenna direct mounting ANT ⎯ WG/HYB (18-38 GHz BAND) Used Not used Waveguide connection Notes:11/13/15 GHz antenna for direct mount is not possible to connect the ordinary waveguide flanges. 2-22 INSTALLATION ROI-S05750 POSITION OF LARGE SIZE O-RING POSITION OF SMALL SIZE O-RING FOR WAVEGUIDE CONNECTION FOR ANTENNA DIRECT MOUNTING ANDREW ANTENNA POSITION OF LARGE SIZE O-RING POSITION OF SMALL SIZE O-RING FOR WAVEGUIDE CONNECTION FOR ANTENNA DIRECT MOUNTING RFS ANTENNA 10-11 GHz BAND 35 4 mm 4 mm 4 mm 32 40 Notes: 1. Do not use both small O-ring and large O-ring simultaneously. 2. O-ring size is different with frequency band as follows: 26 GHz BAND 13-23 GHz BAND 18/23 GHz BAND .8 10 1.8 mm 15 1.8 mm 6m LARGE SIZE O-RING FOR ANTENNA DIRECT MOUNTING 32/38 GHz BAND SMALL SIZE O-RING FOR WAVEGUIDE CONNECTION 2-23 INSTALLATION ROI-S05750 2.6.1 Mounting The method of mounting is listed in Table 2-2 to Table 2-4. Table 2-2 Antenna Direct Mounting Change of Polarization Chart 2-6 ANT/ODU/HYB/TX SPAN ATT ODU/ Bracket HYB TX SPAN ATT OMT Chart 2-7 Chart 2-8 Chart 2-9 Chart 2-11 Table 2-3 Waveguide Connection Using 1+1 HYB 1+0 or Connecting Two Antennas Chart 2-10 Chart 2-12 Table 2-4 Coaxial Cable Connection With/Without HYB Chart 2-13 2-24 INSTALLATION ROI-S05750 Chart 2-6 Change of Polarization (Antenna Direct Mounting) Step Procedure CHANGE OF POLARIZATION ODU DIRECT MOUNTING TYPE ANTENNA (Example (ANDREW) 1/2) Note: The details are referred to the installation manual which is attached to the antenna. The installation or removal of the antenna requires qualified experienced personnel. Note: The antenna is set to V-polarization when shipped from the factory. Keep the antenna stand horizontally, If you change to H polarization, loosen the four screws with the Allen key wrench and then rotate the Transition hub of feed, keeping the antenna stand horizontal. Transition hub 2 SCREWS 2 SCREWS 2-25 INSTALLATION ROI-S05750 Chart 2-6 (Cont’d) Step Procedure Note: Do not remove the screw complete from the screw hole. Hold the feed horn with hand. Holding the feed with hand, rotate the feed 90 degrees, Check that the aperture part of the Transition hub is rotated 90 degrees, then fix it with the screws that were loosened in step 2, Top Top Polarization Polarization Check that the aperture part of the Transition hub is rotated 90 degrees, then fix it with the screws that were loosened in step 2 Note: When a large and a small gasket are included in the antenna package. Please use the large one (The small gasket is not used in antenna mount) 2-26 INSTALLATION ROI-S05750 Chart 2-6 (Cont’d) Step Procedure CHANGE OF POLARIZATION ODU DIRECT MOUNTING TYPE ANTENNA (Example (ANDREW) 2/2) Note: The details are referred to the installation manual which is attached to the antenna. The installation or removal of the antenna requires qualified experienced personnel. Note: The antenna is set to V-polarization when shipped from the factory. 1. Keep the antenna stand horizontally, 2. Loosen six screws with Allen wrench until transition can rotate freely, Note: Do not remove the screw complete from the screw hole. Note: Because of the screwtight is applied, the strength to loosen screw is necessary. Rotate the transition hub 90 degrees until timing pin locates in timing concavity, 2-27 INSTALLATION ROI-S05750 Chart 2-6 (Cont’d) Step Procedure Transition hub Transition hub Transition Hub Timing Pin Vertical Polarized Application Horizontally Polarized Application Tighten six screws when transition hub is located. (Tightening torque is 5.0 N·m ± 10%.) 2-28 INSTALLATION ROI-S05750 Chart 2-6 (Cont’d) Step Procedure CHANGE OF POLARIZATION ODU DIRECT MOUNTING TYPE ANTENNA (Example (RFS)) Note: Note: The details are referred to the installation manual which is attached to the antenna. The installation or removal of the antenna requires qualified experienced personnel. The antenna is set to V-polarization when shipped from the factory. Drain Plug Drain Plug RFS C-Mount RFS SB1 1. 2. 3. 4. Unscrew the 4 screws M3 at the refined steel ring, Hold the feed tightly at the waveguide, Rotate carefully the feed 90 degrees, Mount the feed to the refined steel ring and lock the 4 screws M3. 1. 2. 3. 4. Loosen the 4 screws M3, Hold the feed tightly at the waveguide, Rotate the casting plate carefully the feed 90 degrees, Lock the 4 screws M3. 4 screws (M3) Polarization V Polarization H 2-29 INSTALLATION ROI-S05750 Chart 2-6 (Cont’d) Step Procedure CHANGE OF POLARIZATION OF THE HYB NEC HYBRID Note: The hybrid is set to V-polarization when shipped from the factory. If you change the polarization from V to H, loosen two screws, rotate the transition hub and put it to the HYB. 1Note: There are two types NEC HYBRID. One uses two pieces transition hubs and another uses one piece. GUIDE PIN Cross-Recessed Head Machine Screw M2.6 (2ea) TRANSITION HUB V POLARIZATION H POLARIZATION Two Pieces Transition Hub Type HYB V POLARIZATION Cross- Recessed Head Machine Screw M2.6(2ea) V POLARIZATION H POLARIZATION One Piece Transition Hub Type (Only for 13/15/18/23 GHz HYBRID) 2-30 Then fix it with the two screws that were loosened in step 1. INSTALLATION ROI-S05750 Chart 2-6 (Cont’d) Step Procedure Quasar HYBRID Note: The hybrid is set to V-polarization when shipped from the factory. If you change to H polarization, loosen two screws, rotate the antenna connection unit and put the HYB horizontally. Quasar HYB GUIDE PIN HYB SCREW ANTENNA CONNECTION UNIT V POLARIZAION Check that the aperture of the connection unit is rotated as shown below, then fix it with the two screws that were loosened in step 1. V POLARIZATION H POLARIZATION 2-31 INSTALLATION ROI-S05750 Chart 2-6 (Cont’d) Step Procedure CHANGE OF POLARIZATION OF THE TX SPAN ATT TX SPAN ATT Note: The TX ATT is set to V-polarization when shipped from the factory. If you change to H polarization, loosen two screws, rotate the antenna connection unit and put the TX ATT horizontally. GUIDE PIN TX ATT ANTENNA CONNECTION UNIT V POLARIZATION Check that aperture of the connection unit is rotated as shown below, then fix it with the two screws that were loosened in step 1. Cross-Recessed Head Machine Screw M2.6(2ea) Plate-1 Plate-2 V POLARIZATION H POLARIZATION 38 GHz Band TX SPAN ATT Polarization Change 2-32 INSTALLATION ROI-S05750 NLite EStep Procedure CHANGE OF POLARIZATION OF THE ODU GUIDE PIN GUIDE PIN Antenna Mounting ODU (11-38 GHz Band) 1. When vertical polarization is required, rotate the ODU so as to go up the plate marked V, 2. When horizontal polarization is required, remove the guide pin fixed on the plate marked with V, 3. Screw in the guide pin removed in step 2 to the screw hole of the plate marked H, 4. Rotate the ODU so as to go up the plate marked H, PLATE MARKED WITH V PLATE MARKED WITH H Note: When the ODU is mounted on to the NEC HYB, only V polarization is applied. Note: When the Waveguide or coaxial cable is connected between the ODU and antenna, the ODU in V polarization for up position is recommended for installation. PLATE MARKED WITH V PLATE MARKED WITH H UP UP NLite E IFL IFL NLite E RX LEV MON RX LEV MON FG FG V POLARIZATION H POLARIZATION 10-38 GHz ODU V/H Polarization Conversion 2-33 INSTALLATION ROI-S05750 Chart 2-7 ODU Antenna Direct Mounting (11 - 38 GHz) Step Procedure ANTENNA DIRECT MOUNTING (10-38 GHz Band ODU) Note: The details are referred to the installation manual which is attached to the antenna. INSTALLATION OF BRACKET Install the bracket to the antenna pole, Mount antenna to the bracket, ANDREW POLE MOUNT BRACKET WASHER NUT* WASHER NUT* Three(3) screws* (Apply screwtight to threads before fitting to antenna) Three(3) screws* (Apply screwtight to threads before fitting to antenna) 2-34 PROTECTIVE CAP LOCK WASHER LOCK WASHER Tightening torque of 22 N·m for M10. INSTALLATION ROI-S05750 Chart 2-7 (Cont’d) Step Procedure ANTENNA DIRECT MOUNTING (10-38 GHz Band ODU) RFS SB1 TYPE BRACKET 2-35 INSTALLATION ROI-S05750 Chart 2-7 (Cont’d) Step Procedure Note: The values in the following table are valid for screws and bolts which have been greased according to the installation instructions. Torques for RFS Bolt U-Bolt, V-Bolt (Pipe mount & safety collar) Hexagonal brass nut of fine adjustment (Azimuth, Elevation) Hexagonal socket stainless steel screws (Feed systems install on aluminium mounting plate) Exceptions Fixing screw of the azimuth fine adjustment spindle Special application: NOT greased Fixing screw of the plastic radome 2-36 M5 M6 M8 M10 M12 M10 M8 M10 M12 M3 M4 17 35 50 20 10 17 0.2 0.4 M8 x 30 M12 x 55 8 Nm 17 Nm B4.2 Nm Nm Nm Nm Nm Nm Nm Nm Nm Nm Nm 3 Nm INSTALLATION ROI-S05750 Chart 2-7 (Cont’d) Step Procedure ANTENNA DIRECT MOUNTING (10-38 GHz Band ODU) MOUNT ASSEMBLY (RFS C-Mount Type) Pipe diameter: 48-114mm RFS C-Mount TYPE BRACKET 2-37 INSTALLATION ROI-S05750 RFS C-Mount TYPE BRACKET 2-38 INSTALLATION ROI-S05750 Chart 2-7 (Cont’d) Step Procedure Fix the ODU to the bracket by tightening the M6 screws (four locations), Notes: 1. Figure shows V polarization. 2. Be careful not to damage the O-ring (Antenna). 3. The tightening torque is 4.0 N·m ± 10%. HOLE FOR GUIDE PIN HOLE FOR GUIDE PIN O-RING ODU O-RING ODU ANDREW VHLP TYPE BRACKET 2-39 INSTALLATION ROI-S05750 HOLE FOR GUIDE PIN ODU O-RING RFS SB1 TYPE BRACKET Notes: 1. Figure shows V polarization. 2. Be careful not to damage the O-ring (Antenna). 3. The tightening torque is 4.0 N·m ± 10%. HOLE FOR GUIDE PIN Note: Set the ODU to the bracket after polarization of the ODU is confirmed. O Ring RFS C-Mount TYPE BRACKET Notes: 1. Figure shows V polarization. 2. Be careful not to damage the O-ring (Antenna). 3. The tightening torque is 4.0 N·m ± 10%. 2-40 INSTALLATION ROI-S05750 Chart 2-7 (Cont’d) Step Procedure 4. Insert guide pin on the hole of bracket to set the position of screws, GUIDE PIN ODU FLANGE ANTENNA FLANGE Caution: Align flanges on antenna and ODU correctly, and fix the ODU with four screws. ODU ANTENNA 5. Fix the ODU to the bracket with four screws. Note: Torque: 4.0 N·m ± 10% SCREWS SCREWS 2-41 INSTALLATION ROI-S05750 No.1 ODU POLE ODU POLE MEMBER OF TOWER (S) No.2 ODU MEMBER OF TOWER 1+0 System POLE 1+1 SD System 2-42 Note: Antenna separation (S) is given by path calcuration depending on the system parameter. INSTALLATION ROI-S05750 Chart 2-8 NLite E SONET OC-3Antenna Direct Mounting Using HYBRID Step Procedure MOUNTING Note: The details are referred to the installation manual which is attached to the antenna. HOLE FOR GUIDE PIN O-RING MOUNTING HOLE FOR HYB The tightening torque is 4.0 N·m ± 10%. Be careful not to damage the O-ring(Antenna). ANDREW VHLP TYPE BRACKET 2-43 INSTALLATION ROI-S05750 Chart 2-8 (Cont’d) Step Procedure HOLE FOR GUIDE PIN O-RING HOLE FOR GUIDE PIN O-RING MOUNTING HOLE FOR HYB MOUNTING HOLE FOR HYB RFS SB1 TYPE BRACKET RFS C-Mount TYPE BRACKET Note: The tightening torque is 4.0 N·m ± 10%. Be careful not to damage the O-ring (Antenna). 2-44 INSTALLATION ROI-S05750 Chart 2-8 (Cont’d) Step PUSH Procedure Fix the bracket and handle to the HYB used for 11-52 GHz ODU. Handle M5 HEAD CAP SCREW M5X12(10ea) Bracket Hybrid For 2 screws Type Bracket Note: Tightening torque is 3.0 N·m ± 10%. M5 HEAD CAP SCREW Note: Tightening torque is 3.0 N·m ± 10%. For 4 screws Type Bracket Check the polarization and install the HYB to the antenna by tightening the M6 screws (four locations). 2-45 INSTALLATION ROI-S05750 Chart 2-8 (Cont’d) Step Procedure FLAT WASHER GUIDE PIN M6 SCREW HYB ANT MOVE THE SHORT PLATE O-ring Note: Tightening torque is 4.0 N·m ± 10%. SHORT PLATE O-ring ODU PORT Note: Be careful not to damage the O-ring. Insert the O-rings to the two ODU ports of the HYB. Install the two ODUs with hex screws (four locations) using the Allen key wrench. Note: Be careful not to damage the O-rings (Hybrid). ODU ODU O-ring O-ring ODU For 11-52 GHz ODU Note: Tightening torque is 4.0 N·m ± 10%. 2-46 INSTALLATION ROI-S05750 Chart 2-8 (Cont’d) Step Procedure DEMOUNTING FROM HYB Remove the four (or six) fixed bolts from the ODU. Then demount the ODU. Note: When demounting the ODU from HYB, mount the attached SHORT PLATE to the demounted port of the HYB to avoid RF power leaking from the hybrid and for waterproofing. MOUNTING HOLE FOR SHORT PLATE SHORT PLATE MOUNTING SHORT PLATE TO THE ODU PORT Note: Tightening torque is 3.0 N·m ± 10%. 2-47 INSTALLATION ROI-S05750 Chart 2-9 Antenna Direct Mounting Using TX SPAN ATT Step Procedure MOUNTING TX SPAN ATT Step Procedure Check the polarization of the antenna connection unit of the TX ATT (Refer to CHANGING POLARIZATION description for the TX ATT.) TX ATT Antenna Connection Unit Fix the TX ATT to the antenna by tightening the M6 screws (four locations). Installation to antenna Flat Washer M6 (4ea) Guide Pin Hexagon Socket Head Cap Screw M6 x 30 (4ea) Antenna Tighten the each screw equally and carefully by wrench at diagonal position. TX ATT Packing (Supplied by Antenna) 38A Note; Tightening torque (M6) is 4.0 N·m ± 10%. 38 GHz Band ODU Mounting Using NEC TX SPAN ATT (1/2) 2-48 INSTALLATION ROI-S05750 Chart 2-9 (Cont’d) Step Procedure Insert the O-rings to port of the ODU. Fix the ODU with hex screws (four locations) using the Allen key wrench. Note: Be careful not to damage the O-rings (TX ATT). Attachment of ODU ODU should be attached by turning “V” up. Hexagon Socket Head Cap Screw M6 (Supplied by NEC with ODU) NEC ODU O-Ring TX ATT (Packing) TOP VIEW TOP Antenna TX ATT O-Ring (Packing) 38A ODU ODU Connection Unit Note: Tightening torque is 4.0 N·m ± 10%. SIDE VIEW 38 GHz Band ODU Mounting Using NEC TX SPAN ATT (2/2) 2-49 INSTALLATION ROI-S05750 Chart 2-10 11-38 GHz Band ODU Mounting with HYB (Waveguide Connection) Step Procedure WAVEGUIDE CONNECTION FOR 1+1 HYB No. Parts Name Hybrid (Waveguide Flange Interface Type) Bracket Handle O-ring (for ODU) O-ring (for Waveguide) M5 × 12 Hexagon Socket Head Cap Screw (SS) M3 ×10 Hexagon Head Screw with Washer (×4) (SS) Notr:*For 4 screws Type Bracket Assemble the bracket and handle to the HYB. M5 HEAD CAP SCREW Note: Tightening torque is 3.0 N·m ± 10%. 2-50 Q’ty 10(14)* INSTALLATION ROI-S05750 Chart 2-10 (Cont’d) Step No. Procedure Assemble parts of the pole mounting bracket used to mount the HYB, Parts Name Q’ty Mount Arm Mount Holder Truss M12 × 200 Hexagon Head Screw with Nut (×2), Flat Washer (×2)(ST) M6 ×25 Hexagon Head Screw with Nut (x1), Flat Washer (×2), Spring Washer (SS) M6 × 35 Hexagon Head Screw with Nut ( ×2), Flat Washer (×2)(SS) Truss Mount Arm Mount Holder M12 × 200 Screw 2-51 INSTALLATION ROI-S05750 Chart 2-10 (Cont’d) Step Procedure Screw the Mount Arm and the Truss with the M6 × 25 Screw, Flat Washer (×2), Spring Washer (1), Nut, at four positions, Tightening Torque M6 4.0 N·m ± 10% M12 47 N·m ± 10% Truss Mount Arm Nut M6 x 25 Screw Spring Washer Flat Washer Flat Washer Mount Arm M6x25 Screw, Nut, Flat Washer x 2 Spring Washer Truss Ab.144.3 mm Truss 2-52 Mount Arm INSTALLATION ROI-S05750 Chart 2-10 (Cont’d) Step Procedure Determine centre off set, Mounting Pipe Mounting Pipe Guide Pin Hole (HYB Top) Guide Pin Hole (HYB Top) Centre Off Set Centre Off Set Fit the guide pin of the HYB to the Guide Pin Hole of the Mount Arm, Install the HYB onto the bracket with the M6 × 35 Screw, Flat Washer (×2), Nut (×2), at four positions, 2-53 INSTALLATION ROI-S05750 Chart 2-10 (Cont’d) Step Flat Washer Procedure Flat Washer Nut Nut Guide Pin M6x35 Screw HYB ODU Port Short Plate Short Plate ODU Port Note: When either Main or Standby ODU is removed, attach the short plate over the ODU port. Tightening torque is 3.0 N·m ± 10%. HYB Flat Washer M6 x 35 Screw Nut Nut Mount Arm Flat Washer HYB HYB Top M6x35 Screw, Nut x 2 Flat Washer x 2 2-54 INSTALLATION ROI-S05750 Chart 2-10 (Cont’d) Step Procedure Install the HYB to the mounting pole using the M12 × 200 Screw, Flat Washer, Nut, Mounting Pole Nut Nut Guide Pin Hole Flat Washer M12 x 200 Screw Flat Washer Mount Holder Nut Nut M12 x 200 Screw Flat Washer HYB Mount Holder Mount Holder Flat Washer Mounting Pole Pole Diameter : ø50 to ø115mm Mount Holder M12x200 Screw, Nut x 2 Flat Washer x 2 M12x200 Screw, Nut x 2 Flat Washer x 2 2-55 INSTALLATION ROI-S05750 Chart 2-10 (Cont’d) Step Procedure Adjust direction of the Bracket for Waveguide Port of the HYB orientation, Double Nut tightening Determination of the attachment direction. Tighten double nut after orientation for waveguide connection has been decided. Waveguide Port HYB Confirm the ODU Type, which is Master or Slave, Caution: The same type must be installed onto the HYB. 2-56 INSTALLATION ROI-S05750 Chart 2-10 (Cont’d) Step 10 Procedure Install the ODU onto the HYB, Hexagon Socket Head Cap Screw Main ODU Mark V to Top Guide Pin O-ring (Top View) Note: The ODU should be attached by turning the plate marked “V” up position for both Main ODU and Standby ODU. O-ring Guide Pin Mark V to Top Standby ODU Hexagon Socket Head Cap Screw (Top View) 2-57 INSTALLATION ROI-S05750 Chart 2-10 (Cont’d) Step 11 Procedure Connect the flexible waveguide (WG) to the ODU and fix the waveguide to the ODU with four (4) bolts. Note: Before connecting the WG to the antenna, confirm which polarization is applied to the Master and Slave ODU. Main ODU Mounting Pole Pole Mounting Bracket HYB Standby ODU HYB WG Port WG O-ring Note:Be careful not to damage the O-ring. Note: Tightening torque is 1.4 N·m ± 10%. 2-58 INSTALLATION ROI-S05750 Chart 2-11 11-38 GHz Band ODU Mounting with OMT (Antenna Direct Mounting) Step Procedure This section explains the installation of the OMT for XPIC system. There are two types of O-rings for antenna mounting to the OMT depending on the frequency band. Caution : Do not apply silicon grease to O-ring. POSITION OF LARGE SIZE O-RING POSITION OF LARGE SIZE O-RING FOR ANTENNA DIRECT MOUNTING FOR ANTENNA DIRECT MOUNTING ANDREW ANTENNA RFS ANTENNA 10-11 GHz BAND 35 4 mm 4 mm 4 mm 32 40 Notes: 1. O-ring size is different with frequency band as follows: 13-23 GHz BAND 26-38 GHz BAND 10 .8 1.8 mm 15 1.8 mm .6 LARGE SIZE O-RING FOR ANTENNA DIRECT MOUNTING 13-23 GHz BAND 38 GHz BAND SMALL SIZE O-RING FOR WAVEGUIDE CONNECTION 2-59 INSTALLATION ROI-S05750 Chart 2-11 (Cont’d) Step Procedure For the antenna direct mounting of the ODU, following OMT is used in the XPIC system. FREQUENCY BAND FREQUENCY RANGE (GHz) OMT CODE No. INTERFACE WG INNER DIA.(mm) (ANT Side) INTERFACE (ODU Side) 11G 10.7 −11.7 GHz G9380A 18.0 R100 13G 12.75 −13.25 GHz G9381A 15.0 R140 15G 14.5 −15.35 GHz G9382A 13.5 R140 18G 17.7 −19.7 GHz G9383A 10.5 R220 23G 21.2 −23.6 GHz G9384A 9.0 R220 26G 24.5 −26.5 GHz G9385A 8.0 R260 32G 31.8 −33.4 GHz G9387A 6.5 R320 38G 37 −39.5 GHz G9388A 5.5 R320 Caution : For connecting the OMT to the antenna, the circular type waveguide flange of the antenna is applied to the XPIC system. When the V/H flange is mounted to the antenna, it must be changed to a circular type. Caution : When mounting the ODU to the OMT, confirm the polarization for Main Master and SUB Master ODU. The installation of the corresponding ODUs in the opposite station must have the same polarization in order to make into line Main Master and SUB Master MODEMs. 2-60 INSTALLATION ROI-S05750 Chart 2-11 (Cont’d) Step Procedure Fix the bracket and handle to the OMT. M5 HEAD CAP SCREW Note: Tightening torque is 3.0 N·m ± 10%. GUIDE PIN Fix the OMT to the antenna by tightening them with M6 screws (four locations), FLAT WASHER M6 M6 SCREW MOVE THE SHORT PLATE ANT SCREW O-ring SHORT PLATE Note: Tightening torque is 3.0 N·m ± 10%. Note: Tightening torque is 4.0 N·m ± 10%. Note: Be careful not to damage the O-ring. 2-61 INSTALLATION ROI-S05750 Chart 2-11 (Cont’d) Step Procedure Loosen the two screws and move the short plate if it is fixed to the ODU port. (see figure in step 9), Set the two ODUs to vertical polarization for OMT mounting. If the guide pin behind the plate marked H is mounted, remove the guide pin, Note: The ODU should be attached by turning the plate marked "V" up position for both Main Master ODU and SUB Master ODU. Insert the guide pin removed in step 4 behind the plate marked V, Note: Remove the protection metallic plate covering the waveguide hole on ODU. GUIDE PIN PLATE MARKED WITH V PLATE MARKED WITH V UP NLite E NLite E RX LEV MON IFL Main Master 2-62 FG RX LEV MON IFL Sub Master FG INSTALLATION ROI-S05750 Chart 2-11 (Cont’d) Step Procedure Insert the O-rings to the two ODU ports of the OMT (see figure in step 9), Insert the guide pin into the hole of the OMT and set the position of screws, GUIDE PIN Confirm which polarization is applied to the Master ODU. Check the indication of polarization on the upper side of OMT. Fix the two ODUs with hex screws (four locations) using the allen key wrench, Note: Be careful not to damage the O-rings. POLARIZATION SIDE HEX SCREW ODU ODU O-ring O-ring POLARIZATION SIDE ODU Note: Tightening torque is 4.0 N·m ± 10%. HEX SCREW 2-63 INSTALLATION ROI-S05750 Chart 2-11 (Cont’d) Step Procedure Cautions: 1. Tighten all screws with lighter torque at first, then full torque as specified. 2. When either ODU is demounting for ODU replacing or other reasons, fix the attached short plate to the demounted port of the OMT to avoid leaking of RF power from the OMT and for waterproof. 3. To avoid occurrence of bit errors due to microphonic properties, when installing the SUB Master ODU, protect the Main Master ODU from mechanical knocks. FIXING HOLE FOR SHORT PLATE SHORT PLATE FIXED SHORT PLATE TO THE ODU PORT Note: Tightening torque is 3.0 N·m ± 10%. 2-64 INSTALLATION ROI-S05750 2.7 Feeder Connection The connection method of the waveguide type ODU is described in following procedure. Chart 2-12 Wave Guide Connection Step Procedure Mount a waveguide to the ODU, fix the waveguide to the ODU with four bolts. Note: Be careful not to damage the O-ring. MOUNTING BRACKET THIN NUT THICK NUT SPRING WASHER M6 Tightening torque: 4.0 N·m ± 10% FLAT WASHER O- RING U-BOLT BOLT (M4) SPRING WASHER WAVEGUIDE WASHER Note: Tightening torque is 1.4 N·m ± 10%. Notes: 1. Use suitable flange adapter between ODU and waveguide depending on the waveguide type. 2. Connection of the waveguide is the same way as ODU is wall mounted or 19-inch rack mounted. The wave guide for the antenna direct mounting type ODU is flange adapter is required. Refer to the following procedure. 2-65 INSTALLATION ROI-S05750 Chart 2-12 (Cont’d) Step Procedure Mount the attachment with adapter to the ODU bracket using ten bolts, ODU BRACKET SPRING WASHER Tightening torque: 3.0 N·m ± 10%. BOLT (M5 ×10) Note: Color of adapter is white. WASHER PBR ADAPTER ATTACHMENT Loosen eight nuts and remove the two U-bolts from the ODU bracket, ODU BRACKET U-BOLT NUT 2-66 INSTALLATION ROI-S05750 Chart 2-12 (Cont’d) Step Procedure Mount the ODU bracket to the pole with two U-bolts, Note: The diameter of the pole is from 48.5 to 114.5 millimeters. POLE ODU BRACKET FLAT WASHER SPRING WASHER THICK NUT (M10) THIN NUT (M10) U-BOLT Tightening torque: 34.0 N·m ± 10% Mount the ODU to the ODU bracket with attached four bolts (Align the guide pins on the ODU and the guide holes on the bracket), Note: Be careful not to damage the O-ring. GUIDE PIN O-RING (Note) ODU BRACKET Antenna direct mounting type ODU with NEC special flange. Note: Tightening torque is 4.0 N·m ± 10%. 2-67 INSTALLATION ROI-S05750 Chart 2-12 (Cont’d) Step Procedure 5. Make sure that the ODU and the ODU bracket are fixed at specified values. Mount the waveguide to the ODU with four bolts. Note: Be careful not to damage the O-ring attached to the PBR adapter. O-RING WASHER SPRING WASHER BOLT (M4) WAVEGUIDE WITH PBR( ) FLANGE Note: Tightening torque is 1.4 N·m ± 10%. 2-68 INSTALLATION ROI-S05750 Chart 2-13 ODU Mounting for Connecting Coaxial Cable Step Procedure 6/7/8 GHz ODU MOUNTING (Connecting Coaxial Cable) MOUNTING BRACKET 1. Note:The diameter of pole is from 48.5 to 114.5 millimeters. THIN NUT THICK NUT SPRING WASHER FLAT WASHER Mount the bracket to the pole, point to the opposite station and tighten it with two U-bolts, U-BOLT Tightening torque: 34.0 N·m ± 10% 2. M6 Mount the ODU on to the bracket and tighten four bolts (M6) at upper and lower parts of the ODU, Tightening torque: 4.0 N·m ± 10% 3. Check that the ODU and the bracket are fixed firmly, 2-69 INSTALLATION ROI-S05750 Chart 2-13 (Cont’d) Step Procedure 6/7/8 GHz ODU MOUNTING (Connecting Coaxial Cable) BRACKET 4. Connect the Coaxial cable to the RF IN/OUT connector of the ODU, 5. Down the cable fix bracket to fix the Coaxial cable, then tighten the two bolts, ODU COAXIAL CABLE Tightening torque: 3.0 N·m± 10% Nut TIGHTEN BOLTS (M5) O-Ring Washer Spring Washer ANTENNA Bolt (M4) Transducer (When the wave guide flange is provided to the antenna port, fit the transducer with eight bolts.) Note: Tightening torque is 1.4 N·m ± 10%. POLE 6. ODU COAXIAL CABLE 2-70 Install the Coaxial cables between the antenna and ODU. Note: Fix the coaxial cable to the pole or member with cable hanger or cable ties after antenna orientation has been completed. Caution: Wrap the coaxial cable connection points with a selfbonding tape for waterproof. INSTALLATION ROI-S05750 Straight Type Caution ODU IF CABLE L-Angle Type ODU When connecting the IF cable to the ODU, tighten the N-male connector with engage connector nut only using fingers and holding the cable with another hand. Tighten the engage connector nut only for the L-angle connector also. (Tightening Torque : 0.7 to 1.2 N•m (7 to 12 kg•cm)) IF CABLE L Angle Type ODU If rotate other parts of the L-angle connector as illustrated left, it can cause connector damage. IF CABLE 2-71 INSTALLATION ROI-S05750 Chart 2-13 (Cont’d) Step Procedure 6/7/8 GHz ODU MOUNTING (Connecting Coaxial Cable) BOLT ANT HYB N-Type * No.1 ODU ODU BRACKET COAXIAL CABLE* COAXIAL CABLE TIGHTEN BOLTS (M5) Tightening torque: 3.0 N·m± 10% POLE No.2 ODU SIDE VIEW Note: * When coaxial cable with SMA connector is used, the connectors are supplied by NEC. Caution: Wrap the coaxial cable connection points with a self-bonding tape for waterproof. USING HYB FOR 1+1 SYSTEM 2-72 INSTALLATION ROI-S05750 2.8 Cable Termination In this section, list of tools and material and the method for cable termination method are described. The following cables are described for reference. • D-sub connector (refer to Chart 2-14)* • TNC-P connector of the L angle type for IDU (refer to Chart 2-15)** • N-P connector of the L angle type for ODU (KOMINE made) (refer to Chart 2-16)** • N-P connector of the L angle type for ODU (HIROSE made) (refer to Chart 2-17)** • N-P connector of the straight type for ODU (HIROSE made) (refer to Chart 2-18)** • N-P connector of the straight type for ODU (KOMINE made) (refer to Chart 2-19)** • Molex 5557-04R connector (refer to Chart 2-20) • BNC connector soldering type (refer to Chart 2-21) • BNC connector crimping type (refer to Chart 2-22) • D-Sub High Density Crimp Contacts assembly (refer to Chart 2-23)* Notes: 1. *Use D-sub connectors of less than 16 mm in height as illustrated below. D-SUB CONNECTOR HEIGHT 2. *Use D-sub 44-pins connector for the CTRL of less than 57 mm in width as illustrated below. D-SUB 44 PIN CONNECTOR for the CTRL WIDTH 3. **In 1+1 system, the difference between the No.1 channel IF cable length and the No.2 channel IF cable length should be within 100m. (differential absolute delay time : within 500 ns). Note: Use shielded cables which are connected to the D-Sub/RJ45 connector to suppress interference from affecting the signal and to reduce electromagnetic radiation which may interfere with other signal cables. 2-73 INSTALLATION ROI-S05750 The tools and materials summarized in Table 2-5 are necessary. Table 2-5 Tools and Material List No. 2-74 NAME REMARKS Soldering Iron Solder Knife Measure/Ruler Wire Stripper Adjustable Wrench Hand Crimping Tool CL250-0012-2/ CL250-0013-5 57026-5000/ 57027-5000 09 99 000 0596/ 09 99 000 0513 For D-Sub connector For Molex connector For D-Sub High density connector INSTALLATION ROI-S05750 Chart 2-14 Terminating Supervisory Cables with D-Sub Connector Step Procedure Strip back the cable sheath, taking care not to damage the braided shield. 50 mm CABLE Note: Use shielded cables which are connected to the D-Sub connector to suppress interference from affecting the signal and to reduce electromagnetic radiation which may interfere with other signal cables. Fold back the braided shield (do not separate the strands) and trim it as shown. WIRE Remove 4 mm of insulation from the end of the wire. CONFORMABLE WIRE SOCKET CONTACT AWG#20-24 :CD-PC-111 AWG#24-28 :CD-PC-121 4 mm WIRE 2-75 INSTALLATION ROI-S05750 Chart 2-14 (Cont’d) Step Procedure Insert the cable into the socket contact. WIRE SOCKET CONTACT The cable should be fitted so that insulation and bare wire are arranged as shown. Insert the socket contact into the hand crimping tool. CONFORMING WIRE SOCKET CONTACT AWG#20-24 :TC-CD-111 AWG#24-28 :TC-CD-121 HAND CRIMPING TOOL (HRS TC-CD-111/TC-CD-121) 2-76
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2009:02:20 08:37:57-05:00 Creator : FrameMaker 8.0 Modify Date : 2009:02:20 08:38:06-05:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2009:02:20 08:38:06-05:00 Creator Tool : FrameMaker 8.0 Format : application/pdf Document ID : uuid:7f0bc6f4-ca70-42f7-931e-7d4caa499a37 Instance ID : uuid:11213a5b-87ca-432b-9f7f-fe852d1ecdaa Producer : Acrobat Distiller 6.0 (Windows) Page Count : 70EXIF Metadata provided by EXIF.tools