NIKON TRIMBLE NT0001 Bluetooth module User Manual Focus4 manual 1 p

NIKON-TRIMBLE CO., LTD. Bluetooth module Focus4 manual 1 p

Host 1 user manual 1 of 4

Version 1.00Revision AJanuary 2009User GuideSpectra Precision®Focus® 4 Total Station
2     Spectra Precision Focus 4 Total Station User GuideCorporate OfficeSpectra Precision10355 Westmoor DriveSuite #100Westminster, CO 80021USA+1-720-587-4700 Phone888-477-7516 (Toll free in USA)www.spectraprecision.comLegal NoticesCopyright and Trademarks© 2006-2009, Nikon-Trimble Co. Limited. All rights reserved. All trademarks are the property of their respective owners.Spectra Precision, the Spectra Precision logo, Focus, and the Focus logo are trademarks or registered trademarks of Spectra Precision, registered in the United States and in other countries. The Bluetooth word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by Nikon-Trimble Co. Limited is under license.All other trademarks are the property of their respective owners.Release NoticeThis is the January 2009 release (Revision A) of the Spectra Precision Focus 4 Total Station User Guide. It applies to version 1.00 of the Focus 4 Total Station.ManufacturerNikon-Trimble Co., Ltd.Technoport Mituiseimei Bldg.16-2, Minamikamata 2-chome, Ota-kuTokyo 144-0035 JapanProduct Limited Warranty InformationFor applicable product Limited Warranty information, please refer to the Limited Warranty Card included with this Spectra Precision product, or consult your Spectra Precision Authorized Distribution Partner. NoticesClass B Statement – Notice to Users. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:– Reorient or relocate the receiving antenna.– Increase the separation between the equipment and the receiver.– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.– Consult the dealer or an experienced radio/TV technician for help.Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission rules.CWARNING - This equipment has been certified to comply with the limits for a Class B personal computer and peripherals, pursuant to Subpart B of Part 15 of FCC Rules. Only peripherals (computer input/output devices, terminals, printers, etc.) certified to comply with the Class B limits may be attached to this equipment. Operation with non-certified personal computer and/or peripherals is likely to result in interference to radio and TV reception. The connection of a non-shielded equipment interface cable to this equipment will invalidate the FCC Certification of this device and may cause interference levels which exceed the limits established by the FCC for this equipment.You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.CanadaThis digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of the Canadian Department of Communications.Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de Classe B prescrites dans le règlement sur le brouillage radioélectrique édicté par le Ministère des Communications du Canada.EuropeThis product has been tested and found to comply with the requirements for a Class B device pursuant to European Council Directive 89/336/EEC on EMC, thereby satisfying the requirements for CE Marking and sale within the European Economic Area (EEA). These requirements are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential or commercial environment.Representative in EuropeTrimble GmbHAm Prime Parc 1165478 Raunheim, GermanyAustralia and New ZealandThis product conforms with the regulatory requirements of the Australian Communications Authority (ACA) EMC framework, thus satisfying the requirements for C-Tick Marking and sale within Australia and New Zealand. Taiwan Battery Recycling RequirementsThe product contains a removable Ni-MH battery.Taiwanese regulations require that waste batteries are recycled.⎧᧍ᢂᚾ໲╫Notice to Our European Union CustomersFor product recycling instructions and more information, please go to www.spectraprecision.com/ev.shtm.Recycling in Europe: To recycle Spectra Precision WEEE (Waste Electrical and Electronic Equipment, products that run on electrical power.), Call +31 497 53 24 30, and ask for the "WEEE Associate". Or, mail a request for recycling instructions to:Spectra Precision Europe BVc/o Menlo Worldwide LogisticsMeerheide 455521 DZ Eersel, NL Declaration of ConformityWe, Spectra Precision Limited10355 Westmoor DriveSuite #100Westminster, CO 80021United States of America+1-720-587-4700 declare under sole responsibility that the product:Focus 4 Total Stationcomplies with Part 15 of FCC Rules.Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Spectra Precision Focus 4 Total Station User Guide     3Notices for optional Bluetooth unitUSA FCC Part 15 Subpart/RSS-210, OET bulletin 65 supplement C satisfied.CCAUTION - Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipmentThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:–  Reorient or relocate the receiving antenna.– Increase the separation between the equipment and receiver.– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.– Consult the dealer or an experienced radio/TV technician for help.CanadaRSS-210 Low Power DeviceOperation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.European Union countries, Iceland, Norway, Liechtenstein, Turkey, and SwitzerlandEN300 328v1.7.1, EN50360 satisfiedHereby, Nikon-Trimble Co., Ltd., declares that this instrument is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.Declaration of Conformity available at http://www.nikon-trimble.com/RF exposure compliance – To comply with FCC/IC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons.– This transmitter must not be co-located with or operate in conjunction with any other antenna or transmitter.
4     Spectra Precision Focus 4 Total Station User Guide
Spectra Precision Focus 4 Total Station User Guide     5SafetyFor your safety read the safety and warnings section and this manual carefully and thoroughly before using the Spectra Precision® Focus®4 total station.Although Spectra Precision products are designed for maximum safety, using them incorrectly or disregarding the instructions can cause personal injury or property damage.You should also read the documentation for any other equipment that you use with a Spectra Precision Focus 4 total station.Note – Always keep this user guide near the instrument for easy reference.Warnings and CautionsThe following conventions are used to indicate safety instructions:CWARNING – Warnings alert you to situations that could cause death or serious injury.CCAUTION – Cautions alert you to situations that could cause injury or property damage.Always read and follow the instructions carefully.Rechargeable Lithium-ion (Li-ion) batteriesCWARNING – Do not damage the rechargeable Lithium-ion battery. A damaged battery can cause an explosion or fire, and can result in personal injury and/or property damage. To prevent injury or damage: – Do not use or charge the battery if it appears to be damaged. Signs of damage include,   but are not limited to, discoloration, warping, and leaking battery fluid.– Do not expose the battery to fire, high temperature, or direct sunlight. – Do not immerse the battery in water. – Do not use or store the battery inside a vehicle during hot weather. – Do not drop or puncture the battery. – Do not open the battery or short-circuit its contacts.CWARNING – Avoid contact with the rechargeable Lithium-ion battery if it appears to be leaking. Battery fluid is corrosive, and contact with it can result in personal injury and/or property damage.To prevent injury or damage:– If the battery leaks, avoid contact with the battery fluid. – If battery fluid gets into your eyes, immediately rinse your eyes with clean water and   seek medical attention. Do not rub your eyes! – If battery fluid gets onto your skin or clothing, immediately use clean water to wash off   the battery fluid.
Safety6     Spectra Precision Focus 4 Total Station User GuideCWARNING – Charge and use the rechargeable Lithium-ion battery only in strict accordance with the instructions. Charging or using the battery in unauthorized equipment can cause an explosion or fire, and can result in personal injury and/or equipment damage. To prevent injury or damage: – Do not charge or use the battery if it appears to be damaged or leaking.– Charge the Lithium-ion battery only in a product that is specified to charge it. Be sure to   follow all instructions that are provided with the battery charger. – Discontinue charging a battery that gives off extreme heat or a burning odor.– Use the battery only in equipment that is specified to use it. – Use the battery only for its intended use and according to the instructions in the product   documentation.WarningsBefore using the instrument, read the following warnings and follow the instructions that they provide.CWARNING – Never look at the sun through the telescope. If you do, you may damage or lose your eyesight.CWARNING – The Focus 4 total station is not designed to be explosion-proof. Do not use the instrument in coal mines, in areas contaminated with coal dust, or near other flammable substances.CWARNING – Never disassemble, modify, or repair the instrument yourself. If you do, you may receive electric shocks or burns, or the instrument may catch fire. You may also impair the accuracy of the instrument.CWARNING – Use only the specified battery charger and AC adapter that are supplied with the instrument. Do not use any other charger or adapter as this may cause the battery pack to catch fire or rupture.CWARNING – Do not cover the battery charger and AC adapter while the battery pack is being recharged. The charger must be able to dissipate heat adequately. Coverings such as blankets or clothing can cause the charger to overheat.CWARNING – Avoid recharging the battery pack in humid or dusty places, in direct sunlight, or near heat sources. Do not recharge the battery pack when it is wet. If you do, you may receive electric shocks or burns, or the battery pack may overheat or catch fire.CWARNING – Although the battery pack has an auto-reset circuit breaker, you should take care not to short circuit the contacts. Short circuits can cause the battery pack to catch fire or burn you.
Spectra Precision Focus 4 Total Station User Guide     7SafetyCWARNING – Never burn or heat the battery. Doing so may cause the battery to leak or rupture. A leaking or ruptured battery can cause serious injury.CWARNING – Before storing the battery pack or battery charger, cover the contact points with insulation tape. If you do not cover the contact points, the battery pack or charger may short circuit, causing fire, burns, or damage to the instrument.CWARNING – The battery is not waterproof on its own. Do not get the battery wet when it is removed from the instrument. If water seeps into the battery, it may cause a fire or burns.CautionsBefore using the instrument, read the following cautions and follow the instructions that they provide:CCAUTION – Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous radiation exposure.CCAUTION – The tops of the tripod ferrules are very sharp. When handling or carrying the tripod, take care to avoid injuring yourself on the ferrules.CCAUTION – Before carrying the tripod or the instrument in the carry case, check the shoulder strap and its clasp. If the strap is damaged or the clasp is not securely fastened, the carry case may fall, causing personal injury or instrument damage. The shoulder strap is available as an optional extra.CCAUTION – Before setting up the tripod, make sure that no-one’s hands or feet are underneath it. When the legs of the tripod are being driven into the ground, they could pierce hands or feet.CCAUTION – After mounting the instrument on the tripod, securely fasten the thumb screws on the tripod legs. If the thumb screws are not securely fastened, the tripod may collapse, causing personal injury or instrument damage.CCAUTION – After mounting the instrument on the tripod, securely fasten the clamp screw on the tripod. If the clamp screw is not securely fastened, the instrument may fall off the tripod, causing personal injury or instrument damage.CCAUTION – Securely fasten the tribrach clamp knob. If the knob is not securely fastened, the tribrach may come loose or fall off when you lift the instrument, causing personal injury or instrument damage.
Safety8     Spectra Precision Focus 4 Total Station User GuideCCAUTION – Do not stack objects on the plastic carry case, or use it as a stool. The plastic carry case is unstable and its surface is slippery. Stacking or sitting on the plastic carry case may cause personal injury or instrument damage.CCAUTION – The system in the instrument may stop functioning in order to avoid any errors in measurements when the instrument detects strong electromagnetic wave(s). If this happens, turn off the instrument and remove the source of the electromagnetic wave(s). Then turn on the instrument to resume the work.Laser safetyThe Focus 4 is a Class 2 laser instrument, in accordance with IEC60825-1, Am2 (2001): Safety of Laser Products.To counteract hazards, it is essential for all users to pay careful attention to the safety precautions and control measures specified in the standard IEC60825-1, (2001-08), particularly EN60825-1:1994, A11:1996, and A2:2001, as this refers to the hazard distance that is defined in this User Guide.Note – The hazard distance is the distance from the laser at which beam irradiance or radiant exposure equals the maximum permissible value to which personnel may be exposed without being exposed to health risks.CWARNING – Only qualified and trained persons should be assigned to install, adjust, and operate the laser equipment.CWARNING – Precautions should be taken to ensure that persons do not look directly, with or without an optical instrument, into the beam.CWARNING – Wherever practicable, the laser beam path should be located well above or below eye level.
Spectra Precision Focus 4 Total Station User Guide     9SafetySpecifications for laser emissionConforming standardsLabelsLaser pointer    Wave length 630-680 nm    Output power  CW: Po ≤ 1.0 mWDistance meter    Wave lenght 850-890 nm    Output power Pulse: Po ≤ 6.4 mW    Pulse width < 5 nsLaser plummet (option)    Wave length 635 nm    Output power CW: Po < 1.0 mWEU EN60825-1/Am.2 : 2001 (IEC60825-1/Am.2 : 2001)Laser pointer: Class 2Distance meter: Class 1Laser plummet: Class 2 (Option)USA  FDA21CFR Part 1040 Sec.1040.10 and 1040.11Except for deviations pursuant to Laser Notice No.50, dated June 24, 2007.Complies  with  21  CFR  1040 . 10  and  1040 . 11  except  for  deviations  pursuant  to  Laser  Notice  No . 50 , dated  June  24 , 2007MADE  IN  JAPANTechnoport  Mitsuiseimei  Bldg.16-2,Minamikamata  2-chome, Ota-ku, Tokyo  144-0035  JapanNIKON-TRIMBLE  CO.,LTD.Po<1.0mW       CW  Ё=635nmIEC   60825-1 ,2001LASER  RADIATIONDO  NOT  STARE  INTO  BEAMCLASS  2  LASER  PRODUCTPoɃ1mW  CW  Ё=630-690nmClass  2  Laser  ProductDo  not  stare  into  beamLaser  RadiationIEC60825-1:2001This  device  complies  with  Part  15  of  the  FCC  Rules .Operation  is  subject  to  the  following  two  conditions :1  this  device  may  not  cause  harmful  interference , and2  this  device  must  accept  any  interference  received , including  interference  that  may  cause  undesired  operation.Laser pointer Laser plummet (option)
Safety10     Spectra Precision Focus 4 Total Station User Guide
Spectra Precision Focus 4 Total Station User Guide     11ContentsSafety .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5Warnings and Cautions  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  5Rechargeable Lithium-ion (Li-ion) batteries .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  5Warnings .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  6Cautions  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  7Laser safety .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  8Specifications for laser emission  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  9Conforming standards   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  9Labels .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  91 Introduction   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  17System diagram .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   18Care and maintenance.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   19Environmental conditions  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   19Storage  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   19Cleaning   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   20Adjusting and tightening .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   20Related information  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   212 Setting up the Instrument   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  23Unpacking and repacking the instrument   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   24Charging the battery pack   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   24Applying power .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   26Charging the battery .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   26Conditioning / calibrating a battery .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  27Detaching the battery pack.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   28Attaching the battery pack .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   28Setting up the tripod .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   29Centering the instrument .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   29Centering with the optical plummet.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   29Centering with the laser plummet  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  30Centering with a plumb bob .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   31Leveling the instrument .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   31Focusing the telescope.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   32 Setting the measurement mode and preparing the target  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   33Measurement with a prism.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   33Measurement in reflectorless (N-Prism) mode  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   34Viewing and changing the measurement settings.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  35Target field .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   35Prism constant  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   35
Contents12     Spectra Precision Focus 4 Total Station User Guide3 Getting Started.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  37Parts of the instrument  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   38Instrument keyboard and display    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   40Instrument keyboard  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   40Status bar.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   41LCD backlight, laser pointer, beep sound, and contrast adjustment .  .  .  .  .  .  .  .  .  .  .  .  .   43[DSP] button .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   44[MODE] button .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   46[HOT] key .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   46Bubble indicator  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   47Laser plummet (option).  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   47Turning on the instrument .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   48Turning off the instrument .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   48Sleep mode.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   48Regional configuration.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   49List available jobs or data .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   50Entering data.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   50Entering a point name or number  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  50Entering a code .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   53Advanced feature: Searching for a code using the first character . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  .  54Entering values in feet and inches  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   54Creating or opening a job .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   55Creating a new job .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   55Creating a control job .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   56Measuring distances .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   56Sighting a prism reflector.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   56Taking a distance measurement  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   57Viewing and changing the measurement settings  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   574 Applications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  59HA reset and angle operations.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   60Setting the horizontal angle to 0  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   60Entering the horizontal angle .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   60Station setup .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   60Baseline .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   61Known.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   62Resection .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   64Advanced feature: Viewing and deleting a measurement in resection. .  .  . .  .  . .  .  . .  .  . .  .  .  67Base XYZ  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   67Remote BM   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   68BS Check  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   69Stakeout menu.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   69S-O to Point  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   70L-O from Line .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   71
Spectra Precision Focus 4 Total Station User Guide     13ContentsL-O from Arc.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   72XYZ   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   73Advanced feature: Specifying a layout list by inputting points by range  .  . .  .  . .  .  . .  .  . .  .  .  75Programs menu .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   75Remote distance measurement (RDM) - overview .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   76RDM (Radial)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   77RDM (Cont)  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   77REM .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   78Cogo .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   78Advanced feature: Entering a range of points  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  .  83Advanced feature: Entering angle and distance offsets .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  .  89Recording measurement data  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   90Switching between display screens .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   905 Menu Screen  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  91Job   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   92Opening an existing job .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   92Creating a new job .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   92Deleting a job  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   94Setting the control job.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   95Displaying job information.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   95Settings (basic job settings).  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   96Angle   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   96Distance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   96Coordinate .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   99Communications .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   99Unit  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   99Power saving.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .100Recording.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .100Other settings .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .101Data  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .102Viewing records.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .102Deleting records   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .104Editing raw records   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .106Searching records.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .109Entering coordinates   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .111Communication .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .112Downloading coordinate data.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .112Uploading coordinate data.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .113Advanced feature: Editing the data order for upload .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .  . .  .   1141sec-Key.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .115[MSR] button settings  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .115[DSP] button settings  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .115Calibration  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .116
Contents14     Spectra Precision Focus 4 Total Station User GuideTime  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .1166 Checking and Adjusting .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   117Adjusting the electronic level   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .118Checking and adjusting the circular level .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .118Checking and adjusting the optical/laser plummet.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .118Zero point errors of vertical scale and horizontal angle corrections  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .119Checking the calibration  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .119Adjusting the calibration .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .120The instrument constant .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .121Checking the laser pointer  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .1227 Transferring Coordinate Data   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   123Transferring coordinate data to the total station  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .124Settings  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .124Record format .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .124Data example  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .125Transferring coordinate data from the total station  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .125Settings  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .125Data examples.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .125A Specifications.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   127Main body.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .128Telescope .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .128Measurement range  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .128Distance measurement precision.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .129Measurement intervals  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .129Angle measurement  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .129Tilt sensor  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .130Tangent screws  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .130Tribrach.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .130Level    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .130Optical plummet  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .130Optical laser plummet (option) .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .130Display and keypad   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .130Connections in the base of instrument  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .131Battery pack .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .131Environmental performance.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .131Dimensions  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .131Weight.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .131Environmental protection  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .132Standard components .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .132External device connector  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .132
Spectra Precision Focus 4 Total Station User Guide     15ContentsB Error Messages .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   135Cogo  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .136Communications  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .136Data  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .137Job manager  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .137Stakeout .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .138Programs  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .139Recording data.  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .139Searching  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .140Settings  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .141Station setup .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .141System error  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .142
Contents16     Spectra Precision Focus 4 Total Station User Guide
CHAPTER1Spectra Precision Focus 4 Total Station User Guide     17Introduction 1In this chapter:QSystem diagramQCare and maintenanceQRelated informationThis user guide describes the unique capabilities and features available in the  Spectra Precision®Focus® 4 total station.The software for the Focus 4 total station makes it easy for you to learn to operate one model of instrument and, with little additional training, to apply that knowledge to other models. Before using the instrument, read this user guide carefully. In particular, pay attention to the warnings and cautions that appear in the Safety section, see Safety, page 5.Your comments and suggestions about the Focus 4 total station are welcome. Please contact us at the address given in the front of this manual.In addition, your feedback about the supporting documentation helps us to improve it with each revision. Email your comments to sales@spectraprecision.com.
1     Introduction18     Spectra Precision Focus 4 Total Station User GuideSystem diagramThe system diagram shows the hardware that is used with the Focus 4 total station.Note – You must use the Spectra Precision Focus 4 total station with tribrach W30 or W30b.Focus 4
Spectra Precision Focus 4 Total Station User Guide     19Introduction     1Care and maintenanceBefore using the instrument, read and follow the following maintenance instructions.The Focus 4 total station is a precision instrument that you should store, use, and clean in an appropriate way.CCAUTION – The battery pack contains a Lithium-ion battery. When disposing of the battery pack, follow the laws or rules of your municipal waste system. For more information on the safety warnings associated with the Lithium-ion battery, see Rechargeable Lithium-ion (Li-ion) batteries, page 5.CCAUTION – Store the battery pack with the battery pack discharged.Environmental conditions•Do not leave the instrument in direct sunlight or in a closed vehicle for prolonged periods. Overheating the instrument may reduce its efficiency.•If the total station has been used in wet conditions, immediately wipe off any moisture and dry the instrument completely before returning it to the carry case. The Focus 4 total station contains sensitive electronic assemblies which have been well protected against dust and moisture. However, if dust or moisture gets into it, severe damage could result.•Sudden changes in temperature may cloud the lenses and drastically reduce the measurable distance, or cause an electrical system failure. If there has been a sudden change in temperature, leave the instrument in a closed carry case in a warm location until the temperature of the instrument returns to room temperature.Storage•Do not store the total station in hot or humid locations. In particular, you must store the battery pack in a dry location at a temperature of less than 30 °C (86 °F). High temperature or excessive humidity can cause mold to grow on the lenses. It can also cause the electronic assemblies to deteriorate, and so lead to instrument failure.•Store the battery pack with the battery discharged.•When storing the instrument in areas subject to extremely low temperatures, leave the carry case open.•If the tribrach will not be used for an extended period, lock down the tribrach clamp knob and tighten its safety screw.•The carry case is designed to be watertight, but you should not leave it exposed to rain for an extended period. If exposure to rain is unavoidable, make sure that the carry case is placed with the Spectra Precision nameplate facing upward.
1     Introduction20     Spectra Precision Focus 4 Total Station User GuideCleaning•Do not use organic solvents such as ether or print thinner to clean the non-metallic parts of the instrument, such as the keyboard, or the painted or printed surfaces. Doing so could result in discoloration of the surface or in peeling of printed characters. Clean these parts only with a soft cloth or tissue that is lightly moistened with water or a mild detergent.•To clean the optical lenses, lightly wipe them with a soft cloth or a lens tissue that is moistened with alcohol.Adjusting and tightening•When adjusting the leveling screws, stay as close as possible to the center of each screw’s range. The center is indicated by a line on the screw.•The reticle plate cover has been correctly mounted. Do not release it or subject it to excessive force, for example in an attempt to make it watertight.•Before attaching the battery pack, make sure that the contact surfaces on the battery and Focus 4 total station are clean. •Securely press the cap that covers the data output/external power input connector terminal. The instrument is only watertight if the cap is attached securely or when the data output/external power input connector is used.•The Focus 4 total station is not watertight when the data output/external power input connector is used.•Static electricity from the human body, discharged through the data output/external power input connector, can damage the instrument. Before handling the instrument, touch any other conductive material once in order to remove static electricity.•Be careful not to pinch your finger between the telescope and trunnion of the instrument.Reticle plate cover
Spectra Precision Focus 4 Total Station User Guide     21Introduction     1Related information•Contact your local Spectra Precision dealer for more information about the support agreement contracts for software and firmware, and an extended warranty program for hardware.•Consider a Spectra Precision training course to help you use your total station to its fullest potential. For more information, go to the Spectra Precision website at www.spectraprecision.com. Alternatively, send an email to support@spectraprecision.com.
1     Introduction22     Spectra Precision Focus 4 Total Station User Guide
CHAPTER2Spectra Precision Focus 4 Total Station User Guide     23Setting up the Instrument 2In this chapter:QUnpacking and repacking the instrumentQCharging the battery packQDetaching the battery packQAttaching the battery packQSetting up the tripodQCentering the instrumentQLeveling the instrumentQFocusing the telescopeQSetting the measurement mode and preparing the targetQViewing and changing the measurement settingsThis chapter explains how to prepare the Focus 4 total station before you use it in the field.
2     Setting up the Instrument24     Spectra Precision Focus 4 Total Station User GuideUnpacking and repacking the instrument Note – Handle the Focus 4 total station carefully to protect it from shocks and excessive vibration.To unpack the instrument, grip the carry handle and carefully remove the instrument from the carry case.To replace the instrument in the carry case, place it as shown in the figure.Charging the battery packBefore charging the battery pack, read the following warnings, cautions, and notes.CWARNING – Do not damage the rechargeable Lithium-ion battery. A damaged battery can cause an explosion or fire, and can result in personal injury and/or property damage. To prevent injury or damage: – Do not use or charge the battery if it appears to be damaged. Signs of damage include,   but are not limited to, discoloration, warping, and leaking battery fluid.– Do not expose the battery to fire, high temperature, or direct sunlight. – Do not immerse the battery in water. – Do not use or store the battery inside a vehicle during hot weather. – Do not drop or puncture the battery. – Do not open the battery or short-circuit its contacts.CWARNING – Avoid contact with the rechargeable Lithium-ion battery if it appears to be leaking. Battery fluid is corrosive, and contact with it can result in personal injury and/or property damage.To prevent injury or damage:– If the battery leaks, avoid contact with the battery fluid. – If battery fluid gets into your eyes, immediately rinse your eyes with clean water and   seek medical attention. Do not rub your eyes! – If battery fluid gets onto your skin or clothing, immediately use clean water to wash off   the battery fluid.
Spectra Precision Focus 4 Total Station User Guide     25Setting up the Instrument     2CWARNING – Charge and use the rechargeable Lithium-ion battery only in strict accordance with the instructions. Charging or using the battery in unauthorized equipment can cause an explosion or fire, and can result in personal injury and/or equipment damage. To prevent injury or damage: – Do not charge or use the battery if it appears to be damaged or leaking.– Charge the Lithium-ion battery only in a product that is specified to charge it. Be sure to   follow all instructions that are provided with the battery charger. – Discontinue charging a battery that gives off extreme heat or a burning odor.– Use the battery only in equipment that is specified to use it. – Use the battery only for its intended use and according to the instructions in the product   documentation.CWARNING – To charge the battery pack, use only the battery charger and AC adapter that are supplied with the instrument. Do not use any other charger or you may cause the battery pack to catch fire or rupture. The enclosed battery pack cannot be used with other chargers.CWARNING – Do not cover the battery charger and AC adapter while the battery pack is being recharged. The charger must be able to dissipate heat adequately. Coverings such as blankets or clothing can cause the charger to overheat.CWARNING – Avoid recharging the battery pack in humid or dusty places, in direct sunlight, or near heat sources. Do not recharge the battery pack when it is wet. If you do, you may receive electric shocks or burns, or the battery pack may overheat or catch fire.CWARNING – Although the battery pack has an auto-reset circuit breaker, you should take care not to short circuit the contacts. Short circuits can cause the battery pack to catch fire or burn you.CWARNING – Never burn or heat the battery. Doing so may cause the battery to leak or rupture. A leaking or ruptured battery can cause serious injury.CWARNING – Before storing the battery pack or battery charger, cover the contact points with insulation tape. If you do not cover the contact points, the battery pack or charger may short circuit, causing fire, burns, or damage to the instrument.CWARNING – The battery is not waterproof on its own. Do not get the battery wet when it is removed from the instrument. If water seeps into the battery, it may cause a fire or burns.
2     Setting up the Instrument26     Spectra Precision Focus 4 Total Station User GuideApplying powerPlug in the charger to the supplied AC adapter to turn the unit on. The power input must be 5 V with at least 4 A of current capability. Each battery may take up to 2 A while charging.Charging the batterySlide a battery into either battery slot to begin charging. The adjacent charge indicator will illuminate yellow when charging is in progress. The charge indicator will change to green when charging is complete.Take note of the following:•Charger slots are completely independent so a battery may be inserted regardless of what is occurring in the other battery slot.•Charging may take 2-4 hours if the battery was normally discharged.•Charging may take up to 5 hours with a completely drained battery which has been stored for several months without use.•If the charge indicator(s) are blinking, there is a problem with the battery or with the charger.Battery slot 2Charge light (2) “Calibration on”light (2)Battery slot 1 “Calibration on”light (1)Charge light (1)Calibration buttonTop edge of case5 V, 4 APower jack
Spectra Precision Focus 4 Total Station User Guide     27Setting up the Instrument     2• Lithium-ion batteries should not be charged above 40 °C to 45 °C (104 °F to 113 °F). A blinking charge light may mean that the batteries are too hot for charging. Charging will resume after the batteries cool down.Conditioning / calibrating a batteryYou must calibrate the battery (“condition”) once every 6 months or more often if required. Calibration ensures that the reported remaining battery charge is accurate. To start calibrating a battery, hold down the calibration button on the unit and then insert a battery. Only the battery that was inserted while the button is pressed begins calibration.During battery calibration, the battery will be charged, discharged completely, and then recharged again. Calibration should complete in approximately 17 hours. Do not cover the charger vents during a calibration cycle.•The blue calibration indicator light(s) blink slowly (on 1.5 sec, off 2 sec) while calibration is in progress. The charge light(s) may be on or off during the calibration cycle if the case temperature does not get too high.•When a calibration cycle is completed, the calibration light stops blinking but remains on until the corresponding battery is removed.•Case temperature:–The temperature of the bottom case may continue to climb to approximately 43 °C before temperature regulation is enabled to keep the case from becoming warmer.  As the battery voltage drops, the case cools down and the automatic temperature limiting is no longer necessary. This  minimizes the time required to discharge a battery.–If the case temperature continues to become too hot internally, even after temperature regulation is enabled, there is a secondary failsafe that aborts the calibration completely.  If an abort occurs, the calibration light(s) blink rapidly and battery charging is re-enabled.
2     Setting up the Instrument28     Spectra Precision Focus 4 Total Station User GuideDetaching the battery packCCAUTION – Avoid touching the contacts on the battery pack.1. If the instrument is turned on, press [PWR] to turn it off. 2. Turn the battery box release knob counterclockwise, open the battery box cover and then pull the battery pack out of the battery box.Attaching the battery pack1. Clear any dust or other foreign particles from the battery contacts.2. Turn the battery box release knob counterclockwise and then open the battery box cover.3. Put the battery pack into the battery box. Connect the battery pack at the bottom with the connecting direction faced inside.4. Close the battery box cover and then turn the knob clockwise until you hear a click sound. CCAUTION – If the battery pack is not attached securely, this could adversely affect the watertightness of the instrument.
Spectra Precision Focus 4 Total Station User Guide     29Setting up the Instrument     2Setting up the tripodCCAUTION – The tips of the tripod ferrules are very sharp. When handling or carrying the tripod, take care to avoid injuring yourself on the ferrules.Note – Do not carry the instrument while it is attached to a tripod.1. Open the tripod legs far enough for the instrument to be stable.2. Locate the tripod directly over the station point. To check the position of the tripod, look through the center hole in the tripod head.3. Firmly press the tripod ferrules into the ground.4. Level the top surface of the tripod head.5. Securely fasten the thumb screws on the tripod legs.6. Place the instrument on the tripod head.7. Insert the tripod mounting screw into the center hole of the base plate of the instrument.8. Tighten the tripod mounting screw.Centering the instrumentWhen you center the instrument, you align its central axis precisely over the station point. To center the instrument, you can use the optical plummet, the laser plummet, or a plumb bob. The plumb bob is sold separately.Centering with the optical plummetNote – For high accuracy, check and adjust the optical plummet before you center the instrument. 1. Set up the instrument on the tripod. See above.2. Look through the optical plummet and align the reticle with the station point. To do this, turn the leveling screws until the center mark   of the reticle is directly over the image of the station point.3. While supporting the tripod head with one hand, loosen the tripod leg clamps and adjust the lengths of the legs until the air bubble is in the center of the circular level. 4. Tighten the tripod leg clamps.5. Use the electronic level to level the instrument. See also Leveling the instrument, page 31.
2     Setting up the Instrument30     Spectra Precision Focus 4 Total Station User Guide6. Look through the optical plummet to make sure that the image of the station point is still in the center of the reticle mark.7. If the station point is off-center, do one of the following:–If the station point is slightly off-center, loosen the tripod mounting screw and then center the instrument on the tripod. Use only direct movement to center the instrument. Do not rotate it. When the instrument is centered, tighten the mounting screw. –If there is major displacement of the station point, repeat this procedure starting with Step 2.Centering with the laser plummetCCAUTION – Do not look at the laser directly.Note – For high accuracy, check and adjust the laser plummet before you center the instrument. 1. Set up the instrument on the tripod. See page 29. 2. Turn on the laser plummet.3. Align the laser pointer to the station point. To do this, turn the leveling screws until the laser pointer is over the station point.4. While supporting the tripod head with one hand, loosen the tripod leg clamps and adjust the lengths or the legs until the air bubble is the center of the circular level. 5. Tighten the tripod leg clamps.6. Use the electronic level to level the instrument. See Leveling the instrument, page 31.7. Check that the laser pointer is over the station point.8. If the station point is off-center, do one of the following:–If the station point is slightly off-center, loosen the tripod mounting screw and then center the instrument on the tripod. Use only direct movement to center the instrument. Do not rotate it.When the instrument is centered, tighten the mounting screw.–If there is major displacement of the station point, repeat this procedure starting with Step 2.
Spectra Precision Focus 4 Total Station User Guide     31Setting up the Instrument     2Centering with a plumb bob1. Set up the instrument on the tripod. See page 29. 2. Hang the plumb line on the hook of the tripod mounting screw.3. Adjust the length of the plumb line so that the tip of the plumb bob is at the height of the station point.4. Loosen the tripod mounting screw slightly.5. Using both hands to support the outer side of the tribrach, carefully slide the instrument about on the tripod head until the tip of the plumb bob is positioned over the exact center of the station point.Note – To confirm that the instrument is precisely aligned, check its position from two directions at right-angles to each other.Leveling the instrumentWhen you level the instrument, use the electronic level to you make the vertical axis of the instrument exactly vertical. During leveling, always set the instrument in the Face 1 direction. See Figure 3.1, page 38.To level the instrument: 1. Move the bubble into the circle on the circular level and then turn on the power.2. Rotate the alidade until the bottom edge of the keyboard panel is parallel to the two of the leveling screws (B and C).3. Use leveling screws B and C to move the bubble into the center of the electronic level.4. Rotate the alidade approximately 90°.5. Use leveling screw A to move the bubble into the center of the electronic level.6. Repeat Step 1 through Step 5 to center the bubble in both positions.7. Rotate the alidade 180°. 8. If the bubble in the electronic level remains centered, the instrument is level. If the bubble moves off center, adjust the electronic level. For detailed instructions, see Adjusting the electronic level, page 118.B CA1ABCBottom edgeof the keyboardpanelCBA2Bottom edgeof the keyboardpanel
2     Setting up the Instrument32     Spectra Precision Focus 4 Total Station User GuideFocusing the telescopeCWARNING – Never look at the sun through the telescope. If you do, you may damage or lose your eyesight.When you sight the instrument, you aim the telescope at the target, bring the target image into focus, and align the image with the center cross-hairs of the reticle.To sight the instrument:1. Adjust the diopter: a. Aim the telescope at a blank area, such as the sky or a piece of paper.b. Looking through the eyepiece, rotate the diopter ring until the reticle cross-hairs are in sharp focus.2. Eliminate parallax:a. Aim the telescope at the target image. b. Rotate the focusing ring until the target image is in sharp focus on the reticle cross-hairs. c. Move your eye vertically and laterally to check whether the target image moves relative to the reticle cross-hairs. –If the target image does not move, there is no parallax.–If the target image does move, rotate the telescope focusing ring and repeat Step 2c.3. Rotate the tangent screw. The final turn of the tangent screw should be in a clockwise direction, to align the target accurately on the center cross-hairs.CentercrosshairsDiopter ring Telescopefocusing ring
Spectra Precision Focus 4 Total Station User Guide     33Setting up the Instrument     2 Setting the measurement mode and preparing the targetThe Focus 4 total station has two measurement modes: Prism mode (Prism) and Reflectorless mode (N-Prism). To change the mode at any time from any observation screen, hold down [MSR1] or [MSR2].Set the measurement mode depending on the target that you want to measure, as shown here. In some cases, you can measure to another target that is not appropriate to the set measurement mode.Note – The Focus 4 total station is Laser Class 1 in the measurement function, and Laser Class 2 in the Laser Pointer function. Do not sight the prism when the Laser Pointer is on.Measurement with a prismAs the Focus 4 total station is extremely sensitive, multiple reflections on the prism surface can sometimes cause a significant loss in accuracy.To maintain the accuracy of your measurements:•Use a prism with thin edges. Do not use a prism with scratches, a dirty surface, a chipped center, or thick edges. Target Target settingsPrism, reflector sheet Prism modeOther, reflective materials Reflectorless modeThin edgesChipped center Thick edges
2     Setting up the Instrument34     Spectra Precision Focus 4 Total Station User Guide•When measuring a short distance, incline the prism slightly so that the EDM can ignore unnecessary reflections on the prism surface, as shown below. •Hold the prism securely in place and do not move while taking measurements. In Prism mode, to avoid false measurements on objects other than the prism or reflector-sheet, targets that are less reflective than the prism or reflector sheet are not measured. Even if you start a measurement, measured values are not displayed. To measure less reflective objects, use the N-Prism (Reflectorless) mode.Measurement in reflectorless (N-Prism) modeThe Focus 4 total station enables reflectorless measurements up to 300 m (984 feet).The intensity of the reflection from the target determines the distance the Focus 4 total station can measure in this mode. The color and condition of the target surface also affect the measurable distance, even if the targeted objects are the same. Some less-reflective targets may not be measured.The following table describes some examples of targets and approximate measuring distances:Measurable distances may be shorter or measurement intervals may be longer if either of the following conditions apply:•the angle of the laser against the target is small•the surface of the target is wetIn direct sunlight, the measurable distance may be shorter. In this case, try to throw a shadow on the target.Targets with completely flat surfaces, such as mirrors, cannot be measured unless the beam and the target are perpendicular to each other.Target  You can measure approximately...Traffic signs, reflectors  500 meters (1640 feet)Paper (white), veneer (new)  300 meters (990 feet)wall (brightly painted), brick  100 to 200 meters (330 to 660 feet)Not completely square to the sighting axisCompletely square tothe sighting axis✓✕
Spectra Precision Focus 4 Total Station User Guide     35Setting up the Instrument     2Make sure there are no obstacles between the instrument and the target when taking measurements. When you need to take measurements across a road or a place where vehicles or other objects are frequently moving, take several measurements to a target for the best result.Viewing and changing the measurement settingsHold down [MSR1] or [MSR2] for one second.•To move the cursor between the fields, press [^] or [v].•To change the value in the selected field, press [<] or [>].The available values are:Target fieldIf the measurement is started with the Target field set to Prism mode, there is a dash in front of the prism constant, for example –18 mm.If the measurement is started with the Target field set to N-Prism (Reflectorless) mode, there is square bracket in front of the prism constant, for example ]18 mm.The displayed symbol will continuously move from left to right over the prism constant in the display.Prism constantThe factory default of the prism constant value of the Focus 4 total station is -30 mm.Change the prism constant to match the constant value of the prism you are using. Once you have set up the instrument, you can turn on the Focus 4 total station, change the instrument settings, and start a job. See also page 37.Field ValuesTarget Prism modeN-Prism modeConstant (prism constant)-999 mm through 999 mmMode PreciseNormalTrack Track (continuous MSR) ONTrack (continuous MSR) OFF
2     Setting up the Instrument36     Spectra Precision Focus 4 Total Station User Guide

Navigation menu