ProtoCom_ProtoCom Lon User Manual V.1.02 Proto Com And BACnet Works Protocol Gateway For Shark Nexus Meters E204701
User Manual: Pdf BACnet or LonWorks Converter for Electro Industries Power Meters
Open the PDF directly: View PDF .
Page Count: 104
Download | |
Open PDF In Browser | View PDF |
ProtoCom & ProtoCom Lon TM TM This page intentionally left blank. ProtoCom/ProtoCom-Lon Installation and Operation Manual Version 1.02 Published by: Electro Industries/GaugeTechTM 1800 Shames Drive Westbury, NY 11590 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage or retrieval systems or any future forms of duplication, for any purpose other than the purchaser's use, without the expressed written permission of Electro Industries/GaugeTech. © 2014 Electro Industries/GaugeTech Shark® and Nexus® are registered trademarks of Electro Industries/GaugeTech. The distinctive shapes, styles, and overall appearances of all Shark® and Nexus® devices are trademarks of Electro Industries/GaugeTech. Communicator EXTTM and V-SwitchTM are trademarks of Electro Industries/GaugeTech. Microsoft® and Windows® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Powered by FieldServer. Metasys® is a registered trademark of Johnson Controls, Inc. LonWorks® is a registered trademark of Echelon Corp. BACnet® is a registered trademark of ASHRAE. Modbus® is a registered trademark of Schneider Electric, licensed to the Modus Organization, Inc. Electro Industries/GaugeTech Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 i This page intentionally left blank. Electro Industries/GaugeTech Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 ii Customer Service and Support Customer support is available 9:00 am to 4:30 pm, Eastern Standard Time, Monday through Friday. Please have the model, serial number and a detailed problem description available. If the problem concerns a particular reading, please have all meter readings available. When returning any merchandise to EIG, a return materials authorization number is required. For customer or technical assistance, repair or calibration, phone 516-334-0870 or fax 516-338-4741. Product Warranty Electro Industries/GaugeTech warrants all products to be free from defects in material and workmanship for a period of four years from the date of shipment. During the warranty period, we will, at our option, either repair or replace any product that proves to be defective. To exercise this warranty, fax or call our customer-support department. You will receive prompt assistance and return instructions. Send the instrument, transportation prepaid, to EIG at 1800 Shames Drive, Westbury, NY 11590. Repairs will be made and the instrument will be returned. This warranty does not apply to defects resulting from unauthorized modification, misuse, or use for any reason other than electrical power monitoring. The ProtoCom/ ProtoCom-Lon unit is not a user-serviceable product. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ELECTRO INDUSTRIES/ GAUGETECH SHALL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING FROM ANY AUTHORIZED OR UNAUTHORIZED USE OF ANY ELECTRO INDUSTRIES/GAUGETECH PRODUCT. LIABILITY SHALL BE LIMITED TO THE ORIGINAL COST OF THE PRODUCT SOLD. Electro Industries/GaugeTech Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 iii Use Of Product for Protection Our products are not to be used for primary over-current protection. Any protection feature in our products is to be used for alarm or secondary protection only. Disclaimer The information presented in this publication has been carefully checked for reliability; however, no responsibility is assumed for inaccuracies. The information contained in this document is subject to change without notice. Safety Symbols In this manual, this symbol indicates that the operator must refer to an important WARNING or CAUTION in the operating instructions. Please see Chapter 4 for important safety information regarding installation and hookup of the ProtoCom/ProtoCom-Lon unit. Dans ce manuel, ce symbole indique que l’opérateur doit se référer à un important AVERTISSEMENT ou une MISE EN GARDE dans les instructions opérationnelles. Veuillez consulter le chapitre 4 pour des informations importantes relatives à l’installation et branchement de ProtoCom/ProtoCom-Lon. UL Compliance For UL compliance, the following instructions must be met when operating the ProtoCom/ProtoCom-Lon: • The units shall be powered by listed LPS or Class 2 power supply suited to the expected operating temperature range. • The interconnecting power connector and power cable shall: • Comply with local electrical code • Be suited to the expected operating temperature range • Meet the current and voltage rating for the ProtoCom/ProtoCom-Lon • Furthermore, the interconnecting power cable shall: • Be of length not exceeding 3.05m (118.3") Electro Industries/GaugeTech Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 iv • Be constructed of materials rated VW-1 or FT-1 or better • If the unit is to be installed in an operating environment with a temperature above 65 °C, it should be installed in a Restricted Access Area requiring a key or a special tool to gain access. • This device must not be connected to a LAN segment with outdoor wiring. About Electro Industries/GaugeTech (EIG) Founded in 1975 by engineer and inventor Dr. Samuel Kagan, Electro Industries/ GaugeTech changed the face of power monitoring forever with its first breakthrough innovation: an affordable, easy-to-use AC power meter. More than thirty years since its founding, Electro Industries/GaugeTech, the leader in power monitoring and control, continues to revolutionize the industry with the highest quality, cutting edge power monitoring and control technology on the market today. An ISO 9001:2008 certified company, EIG sets the industry standard for advanced power quality and reporting, revenue metering and substation data acquisition and control. EIG products can be found on site at mainly all of today's leading manufacturers, industrial giants and utilities. EIG products are primarily designed, manufactured, tested and calibrated at our facility in Westbury, New York. Electro Industries/GaugeTech Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 v Revision History The following table lists revision information for this manual, Doc #E204701, the ProtoCom/ProtoCom-Lon Installation and Operation Manual. Version Number Revision Date Summary of Changes V.1.01 8/6/2014 First release V.1.02 9/10/2014 Section 1.9 reorganized and Section 1.9.1 added - DIN Rail installation instructions Electro Industries/GaugeTech Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 vi Table of Contents Table of Contents Customer Service and Support iii Product Warranty iii Use Of Product for Protection iv Disclaimer iv Safety Symbols iv UL Compliance iv About Electro Industries/GaugeTech (EIG) v Revision History vi 1: Introduction to the ProtoCom/ProtoCom-Lon 1-1 1.1: Overview of the ProtoCom/ProtoCom-Lon Gateway 1-1 1.2: EIG Devices and Available Point Count 1-2 1.3: Specifications 1-3 1.4: ProtoCom/ProtoCom-Lon Dimensions 1-4 1.5: Electrical Connections 1-5 1.6: Use of DIP Switches 1-7 1.7: Removing the Top Cover from the ProtoCom/ProtoCom-Lon (ONLY if Necessary) 1-8 1.7.1: Replacing the Top Cover 1-11 1.8: Graphical User Interface (GUI) Configurator 1-11 1.9: ProtoCom/ProtoCom-Lon Installation 1-13 1.9.1: Mounting on a DIN Rail 1-13 1.9.2: Mounting on a Panel 1-14 Electro Industries/GaugeTech Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 TOC-1 Table of Contents 1.10: The Rest of This Manual 1-15 2: Using the ProtoCom/ProtoCom-Lon 2-1 2.1: Step One - Configure Modbus Communication Settings 2-1 2.2: Step Two - Select the Desired Field BAS Protocol (ProtoCom only) 2-3 2.3: Step Three - Enable Auto-discovery 2-4 2.4: Step Four - Set MAC Address/Device Instance/Node-ID (Proto-Com only) 2-5 2.4.1: Set MAC Address - for BACnet MS/TP Protocol Only 2-5 2.4.2: Set the Device Instance - for BACnet MS/TP and BACnet/IP Protocols 2-6 2.4.2.1: Change Node_Offset Value 2-6 2.4.3: Device Node-ID for Metasys N2, Modbus/TCP, and DF1 Protocols 2-7 2.5: Step 5: Set the Baud Rate for BACnet MS/TP and DF1 Protocols 2-8 2.6: Step 6 - Connect the ProtoCom/ProtoCom-Lon to the Meter 2-9 2.6.1: Biasing the Modbus RS485 Network (only if necessary) 2-11 2.6.2: Set End of Line Termination Switch for the Modbus RS485 Port (only if necessary) 2-12 2.7: Step 7 - Connect to the RS485/LonWorks Network (BACnet MS/TP, Metasys N2, DF1, or LonWorks) 2.8: Step 8 - Connect Power to the ProtoCom/ProtoCom-Lon 2-13 2-14 2.9: Step 9 - Turn Off Auto-discovery After Completion to Save Configuration 2-15 2.10: Step 10: Additional Configuration Electro Industries/GaugeTech Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions The Leader In Power Monitoring and Smart Grid Solutions 2-16 Doc# E204701 TOC-2 Table of Contents 2.10.1: Use the Web GUI to Configure IP Address for BACnet IP and EtherNet/IP 2-16 2.10.2: Set Up a Password 2-20 2.10.3: Configure the ProtoCom-Lon 2-22 2.11: Step 11 - Use the CAS BACnet Explorer to Validate the ProtoCom in the Field (BACnet MS/TP or BACnet/IP) 2-24 2.11.1: CAS BACnet Setup 2-26 3: Device Communication 3-1 3.1: LED Diagnostics for Modbus RTU Communications Between ProtoCom/ProtoCom-Lon and Devices 3-1 3.2: Communication Problems 3-2 3.2.1: No Communication on Modbus RTU (Meter) Side 3-2 3.2.2: Field Communication Problems 3-2 A: Protocol Data Points for EIG Meters A-1 A.1: Shark® 100 Meter A-2 A.2: Shark® 200 Meter A-4 A.3: Nexus® 1252/1262/1272 Meters A-7 A.4: DMMS 425 Meter A-9 A.5: Nexus® 1500 Meter A-11 A.6: MP200-Y Metering System A-13 A.7: MP200-S Metering System A-20 B: MAC Address DIP Switch Settings B-1 Electro Industries/GaugeTech Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 TOC-3 Table of Contents This page intentionally left blank. Electro Industries/GaugeTech Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 TOC-4 1: Introduction to the ProtoCom/ProtoCom-Lon 1: Introduction to the ProtoCom/ ProtoCom-Lon 1.1: Overview of the ProtoCom/ProtoCom-Lon Gateway The ProtoCom/ProtoComLon is an external, high performance Building Automation System (BAS) multi-protocol gateway that is pre-configured to automatically communicate between Electro Industries/ Gaugetech (EIG) meters and various building automation protocols. The ProtoCom supports: Figure 1.1: ProtoCom/ProtoCom-Lon BACnet® MS/TP, BACnet®/IP, Johnson Controls’ Metasys® N2, EtherNet/IP and DF1, and Modbus® TCP protocols; and the ProtoCom-Lon supports the LonWorks® protocol. With the ProtoCom, the meters’ Modbus communication is converted into BACnet or other popular BAS protocols. With the ProtoCom-Lon, the meters’ Modbus communication is converted into LonWorks® protocol. The ProtoCom/ProtoCom-Lon connects to the EIG meter’s RS485 port. Once connected, the ProtoCom/ProtoCom-Lon unit auto-detects the EIG meter model it is connected to, and loads the pre-configured protocol data points for that meter, e.g., the Shark® 200 meter’s BACnet® objects. You do not need to do manual mapping of the meter’s Modbus points. The ProtoCom/ProtoCom-Lon is shipped as a kit (ProtoCom-KT/ProtoCom-Lon-KT) which consists of the unit, a power supply, a communication cable, a one page Quickstart guide, and this manual on a CD. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-1 1: Introduction to the ProtoCom/ProtoCom-Lon 1.2: EIG Devices and Available Point Count The total number of devices attached to ProtoCom cannot exceed 1500 Modbus registers for BACnet MS/TP, BACnet/IP, Modbus/TCP, Metasys N2, EtherNet/IP, or DF1. The total number of devices attached to ProtoCom-Lon cannot exceed 1000 Modbus registers for LonWorks. Refer to the following table for the supported EIG meters and their associated data points. Point Count Devices Shark® 100 Meter 56 Shark® 200 Meter 68 Nexus® 1252 1262 1272 Meters 48 DMMS 425 Meter 46 Nexus® 1500 Meter 56 MP200-Y Metering System 241 MP200-S Metering System 571 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-2 1: Introduction to the ProtoCom/ProtoCom-Lon 1.3: Specifications Electrical Connections Approvals: ProtoCom One 6‐pin Phoenix connector, one RS485 +/‐ ground port, power +/‐ frame ground port One 3‐pin RS485 Phoenix connector, one RS485 +/‐ ground port One Ethernet‐10/100 Ethernet port ProtoCom‐Lon One 6‐pin Phoenix connector, one RS485 +/‐ ground port, power +/‐ frame ground port One Ethernet 10/100 BaseT port One FTT‐10 LonWorks port CE Certified; TUV approved to UL 916, EN 60950‐1, EN 50491‐3 and CSA C22‐2 standards; FCC Class A Part 15; OPC Self‐tested for Compliance; RoHS Compliant; CSA 205 Approved Power Multi‐mode power adapter: 9‐30VDC or 12 ‐ 24VAC Requirements Physical 11.5 cm L x 8.3 cm W x 4.1 cm H (4.5 x 3.2 x 1.6 in.) Dimensions Weight: 0.2 kg (0.4 lbs) Operating ‐40°C to 75°C (‐40°F to167°F) Temperature: Surge Suppression EN61000‐4‐2 ESD EN61000‐4‐3 EMC EN61000‐4‐4 EFT Humidity: 5 ‐ 90% RH (non‐condensing) (Specifications subject to change without notice) Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-3 1: Introduction to the ProtoCom/ProtoCom-Lon 1.4: ProtoCom/ProtoCom-Lon Dimensions Figure 1.2: ProtoCom Dimensions in inches[cm] Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-4 1: Introduction to the ProtoCom/ProtoCom-Lon 1.5: Electrical Connections RS485 Port to Field Protocol LEDs: Field RS485 Rx/Tx End of Line Termination Switch LEDs: RUN, ERR, Offline, RUN2 Additional DIP Switches: Only A1 and A2 are Enabled A Bank - MAC Address B Bank - Baud Rate S Bank - Protocol/ Config PWR LEDs RS485 Bias Jumpers SPL RUN ERR RX TX PWR RS485 Termination Jumper 6-pin Connector - Host RS485 and Power Connections Figure 1.3: ProtoCom Electrical Connections Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-5 1: Introduction to the ProtoCom/ProtoCom-Lon R LonWorks Field Connection LonWorks LED LonWorks Service Pin A Bank - Node-ID RUN LED Additional DIP Switches: Only A1 and A2 are Enabled B Bank - Baud Rate S Bank - Protocol/ Config LonWorks Rx LEDs RS485 Bias Jumpers SPL RUN ERR RX TX PWR RS485 Termination Jumper 6-pin Connector - Host RS485 and Power Connections Figure 1.4: ProtoCom-Lon Electrical Connections Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-6 1: Introduction to the ProtoCom/ProtoCom-Lon 1.6: Use of DIP Switches The ProtoCom/ProtoCom-Lon makes use of DIP Switches for many of its settings. There are 3 banks of DIP Switches on the ProtoCom/ProtoCom-Lon, but on the ProtoCom-Lon the S bank of DIP Switches is disabled, as it is not used. See the figure below. WARNING! When setting DIP Switches, ensure that power to the ProtoCom/ProtoCom-Lon is OFF. AVERTISSEMENT! Lors de la configuration des commutateurs DIP, veiller à ce que l’alimentation au ProtoCom/ProtoCom-Lon est DÉSACTIVÉE. DIP Switch OFF ON Figure 1.5: DIP Switches • To set a DIP Switch ON, move it toward the center of the ProtoCom/ProtoCom-Lon. • To set a DIP Switch OFF, move it toward the outside edge of the ProtoCom/ProtoCom-Lon. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-7 1: Introduction to the ProtoCom/ProtoCom-Lon 1.7: Removing the Top Cover from the ProtoCom/ProtoCom-Lon (ONLY if Necessary) There are two situations (biasing and end-of-line termination, described in Chapter 2) in which you may need to adjust internal jumpers. To do so you need to separate the top cover from the main part of the unit. CAUTION! Be sure the ProtoCom/ProtoCom-Lon is POWERED OFF. ATTENTION! Veiller à ce que l’alimentation au ProtoCom/ProtoCom-Lon est DÉSACTIVÉE. Recommended Procedure to remove the top cover: Using a flat-sided screw driver or similar tool, gently insert it into the 4 slots in the back of the ProtoCom/ProtoCom-Lon, alternating between slots until the cover is loosened enough to be removed. Refer to the diagram below. Slots for removing cover (4) Figure 1.6: Slots in ProtoCom/ProtoCom-Lon Back Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-8 1: Introduction to the ProtoCom/ProtoCom-Lon Alternate Procedure to remove the top cover: 1. Hold the ProtoCom/ProtoCom-Lon firmly with both hands and turn it over, so that the back is facing you. 2. Position your thumbs as shown in the figure below and press outward on both sides to fractionally move the sides away from the back of the unit. FIELD Connector 2.Put right thumb here 1.Put left thumb here 3.Pull outward slightly with thumbs on both left and right edges of top cover (in direction of red arrows) 4.Using either index finger, pull forward on the FIELD connector to move the main unit toward you about .25” Figure 1.7: Removing the Top Cover, Part 1 3. While keeping your thumbs in this position, use your index finger to pull the top RS485 connector (labeled Field) toward you. The top back of the ProtoCom will be freed from the top cover and move toward you about .25”. 4. Keeping the back of the ProtoCom facing you, turn the unit so that the 6 pin connector (labeled HOST) is at the top. Once again, press outward with your Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-9 1: Introduction to the ProtoCom/ProtoCom-Lon thumbs as shown in the diagram below and pull the HOST connector toward you. The main part of the ProtoCom/ProtoCom-Lon will be freed from the top cover. HOST Connector 2.Put right thumb here 1.Put left thumb here 3.Pull outward slightly with thumbs on both left and right edges of top cover (in direction of red arrows) 4.Using either index finger, pull forward on the HOST connector to free the main unit Figure 1.8: Removing the Top Cover, Part 2 NOTE: The plastic LED lens will come loose when the top cover is removed. It must be replaced as shown in 9he drawing below. Plastic LED Lens fits here Figure 1.9: Position of the LED Lens Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-10 1: Introduction to the ProtoCom/ProtoCom-Lon 1.7.1: Replacing the Top Cover To replace the cover: 1. Make sure the LED lens has been returned to its correct position (see Figure 1.8). 2. Carefully position the top cover over the main unit and press gently until it clicks into place. 1.8: Graphical User Interface (GUI) Configurator The ProtoCom/ProtoCom-Lon has an embedded GUI Configurator which can be used to program the Node Offset or change the IP address (see Section 2.10.1), or to set up a password for the ProtoCom/ProtoCom-Lon (see Section 2.10.2). To open the GUI Configurator: 1. Connect a standard CAT5 Ethernet cable (straight or crossover) from your PC to the RJ45 Ethernet port on the ProtoCom/ProtoCom-Lon. Insert the Ethernet cable into the unit’s RJ45 port Figure 1.10: ProtoCom/ProtoCom-Lon Ethernet Port 2. The Default IP Address of ProtoCom/ProtoCom-Lon is 192.168.1.24, and the Subnet Mask is 255.255.255.0. If the PC and ProtoCom/ProtoCom-Lon are on different IP Networks, assign a static IP Address to the PC on the 192.168.1.xxx network: a. Go to > > b. Right-click on Local Area Connection > Properties. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-11 1: Introduction to the ProtoCom/ProtoCom-Lon c. Highlight > d. Select: Use the following IP address and enter the information below. e. Click twice. 3. Open a browser application on your PC. NOTE: You do not need to be connected to the Internet. 4. Type the ProtoCom/ProtoCom-Lon’s default IP address 192.168.1.24 in the browser address bar and press Enter to open the GUI. You will see the screen shown below. NOTES: • The example screen above is for a ProtoCom running BACnet MSTP. The screen will look a bit different if you are running another protocol. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-12 1: Introduction to the ProtoCom/ProtoCom-Lon • If the IP address of the ProtoCom has been changed by previous configuration, you will need to get the assigned IP address from the network administrator. 1.9: ProtoCom/ProtoCom-Lon Installation You have two choices for installing the ProtoCom/ProtoCom-Lon: • Mounting on a DIN rail using the DIN Rail clip that came attached to the unit • Mounting on a panel using the unit’s mounting holes 1.9.1: Mounting on a DIN Rail The ProtoCom/ProtoCom-Lon comes with an attached DIN Rail clip. Top edge of clip Butterfly spring Two screws hold the clip onto the unit DIN Rail clip Bottom edge of clip Figure 1.11: DIN Rail Clip To mount the unit on a DIN Rail: 1. Latch the top edge of the clip onto the DIN Rail and push down on the unit to compress the butterfly spring. 2. Clip the bottom edge of the clip onto the DIN rail and stop pushing down on the unit. The butterfly spring will hold the unit in place. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-13 1: Introduction to the ProtoCom/ProtoCom-Lon To remove the unit from the DIN Rail: 1. Push down on the unit to compress the butterfly spring. 2. Pull the bottom of the unit away from the DIN Rail to release the bottom edge of the clip. 3. Unhook the clip from the top of the DIN Rail. 1.9.2: Mounting on a Panel The ProtoCom/ProtoCom-Lon has mounting holes in its tabs for installation in a panel. Mounting Holes Figure 1.12: Location of Mounting Holes 1. Using a #1 flat-blade screwdriver, unscrew the two screws holding the DIN Rail clip to the back of the ProtoCom/ProtoCom-Lom (see Figure 1.11) and remove the clip. 2. Verify that the area where the unit is to be mounted allows proper clearance for all connections and mount the unit using the holes provided, spaced 3.25" apart. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-14 1: Introduction to the ProtoCom/ProtoCom-Lon 1.10: Navigating This Manual Chapter 2 explains how to use the ProtoCom/ProtoCom-Lon with EIG meters, including configuration and wiring. Chapter 3 contains information on device communication. Appendix A contains the EIG meters points list for the supported protocols. Appendix B contains the A Bank DIP Switch settings for MAC address. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-15 1: Introduction to the ProtoCom/ProtoCom-Lon This page intentionally left blank. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 1-16 2: Using the ProtoCom/ProtoCom-Lon 2: Using the ProtoCom/ProtoCom-Lon This chapter outlines the procedure for setting up communication between the ProtoCom/ProtoCom-Lon and an EIG meter. 2.1: Step One - Configure Modbus Communication Settings The ProtoCom/ProtoCom-Lon is designed to connect to the RS485 Modbus port of an EIG power meter and to convert the serial communication to the desired protocol. Depending on the meter’s point count (see Section 1.2), the ProtoCom/ProtoCom-Lon can communicate with more than one meter. Each meter must have an independent RS485 Modbus address. See the example configuration below. R BACnet Building Management System BACnet/IP ProtoCom RS485 R Shark 200 Meter R Shark 200 Meter R Nexus 1500 Meter Figure 2.1: Example of Meters, ProtoCom, and Protocol Communication Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-1 2: Using the ProtoCom/ProtoCom-Lon All devices connected to the ProtoCom/ProtoCom-Lon MUST have the same Baud Rate, Data Bits, Stop Bits, and Parity. Refer to the following table, which shows the default communication settings. Serial Port Setting Device Protocol Modbus RTU Baud Rate 9600 Parity None Data Bits 8 Stop Bits 1 1. Assign a Modbus Address to each of the devices attached to the ProtoCom/ProtoCom-Lon. The Modbus Address needs to be uniquely assigned between 1 and 255. 2. Record the Modbus Address assigned to each device. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-2 2: Using the ProtoCom/ProtoCom-Lon 2.2: Step Two - Select the Desired Field BAS Protocol (ProtoCom only) You will use the S Bank Dip Switches to choose from BACnet MS/TP, BACnet/IP, Modbus/TCP, Metasys N2, EtherNet/IP, or DF1 (refer to Section 1.6 for an explanation of the DIP switches). Note that the ProtoCom’s default setting enables BACnet, so you don’t need to change this setting unless you want to use another protocol. WARNING! When setting DIP Switches, please ensure that power to the board is OFF. AVERTISSEMENT! Lors de la configuration des commutateurs DIP, veiller à ce que l’alimentation au ProtoCom/ProtoCom-Lon est DÉSACTIVÉE. S0 S1 S2 S3 Figure 2.2: S Bank of DIP Switches • The S bank of DIP switches, S0 - S3 is used to select BACnet MS/TP, BACnet/IP, Modbus/TCP, Metasys N2, EtherNet/IP, or DF1 protocols on ProtoCom. • The following chart describes S0 - S3 DIP switch configuration settings for the devices to support BACnet MS/TP, BACnet/IP, Modbus TCP, Metasys N2, EtherNet/IP, or DF1 protocols on a ProtoCom. ProtoCom Protocol BACnet IP BACnet MSTP Metasys N2 EtherNet/IP DF1 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions S0 Off On Off On Off Doc# S Bank DIP Switches S1 S2 Off Off Off Off On Off On Off Off On E204701 2-3 2: Using the ProtoCom/ProtoCom-Lon NOTES: • When the S bank of switches are all off (this is the default setting) BACnet/IP is enabled. • The OFF position is when the DIP switches are set closest to the outside of the box. • On the ProtoCom-Lon, the S bank DIP switches are disabled, since the Field Protocol is always LonWorks. 2.3: Step Three - Enable Auto-discovery The ProtoCom/ProtoCom-Lon has an Auto-discovery feature that lets it determine the EIG meter model it is connected to, and automatically load the appropriate points list for the protocol you choose. This makes configuration simple. The ProtoCom/ProtoCom-Lon allows a user to put different EIG meters on the RS485 bus, and have the ProtoCom/ProtoCom-Lon automatically discover them and make them available via the selected protocol. Auto-discovery is set in the S Dip Switch bank’s S3 switch (see DIP Switch figure on the previous page). The setting configuration is shown in the table below. ProtoCom Auto‐Discovery Settings Auto‐Discovery ON ‐ Build New Configuration Auto‐Discovery OFF ‐ Save Current Configuration S Bank DIP Switches S3 On Off When installing the ProtoCom for the first time, set S3 to the ON position to enable Auto-discovery. The ON position is when the DIP switches are set closest to the inside of the box. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-4 2: Using the ProtoCom/ProtoCom-Lon 2.4: Step Four - Set MAC Address/Device Instance/Node-ID (ProtoCom only) The Building Management System (BMS) in use must be able to distinguish the ProtoCom, and the meters attached to it, from all of the other devices in the BMS system. For this reason, the ProtoCom and connected devices must be given a unique ID. The specific ID you need to set depends on the BMS protocol you’ll be using. • MAC Address - used for BACnet MS/TP protocol only (Section 2.4.1): this is an eight bit address used to identify devices on a single RS485 subnet (the devices attached to the ProtoCom when using BACnet MS/TP). It identifies the ProtoCom to the BACnet MS/TP protocol. • Device Instance - used for both BACnet MS/TP and BACnet/IP (Section 2.4.2): the Device Instance is used to set up a unique identifier for each of the meters attached to the ProtoCom. • Node-ID - used for Metasys N2, Modbus/TCP, and DF1 (Section 2.4.3): this is the unique identifier for each of the meters attached to the ProtoCom. 2.4.1: Set MAC Address - for BACnet MS/TP Protocol Only • Note that only 1 MAC address is set for the ProtoCom, regardless of how many devices are connected to it. • Set the BACnet MS/TP MAC address between 1 and 127 (Master MAC address): this is so that the BMS system can find the ProtoCom via BACnet auto discovery. • Use DIP switches A0 - A7 to assign the MAC Address for BACnet MS/TP. Figure 2.2: A Bank of DIP Switches Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-5 2: Using the ProtoCom/ProtoCom-Lon NOTES: • Refer to Appendix C.1 for the MAC address DIP switch chart. • When using Metasys N2, Modbus/TCP, and DF1 the A Bank of DIP switches are disabled and not used. They should be set to the OFF position. 2.4.2: Set the Device Instance - for BACnet MS/TP and BACnet/IP Protocols The BACnet protocol needs a value called Device Instance for each device in the system. This Device Instance is used to uniquely identify the device in a BACnet system. The BACnet Device Instance is set up by adding a value known as the Node_Offset to the Modbus Address that you assigned to the device in step 1 (Section 2.1). The BACnet Device Instance can range from 1 to 4,194,303. The default Node_Offset is 50,000. For example, using the Node_Offset default of 50,000: a. If Device 1 has a Modbus Address of 1, Device 2 has a Modbus Address of 2, Device 3 has a Modbus Address of 3; b. The Device Instance for Device 1 is 50,001; for Device 2 it is 50,002; and for Device 3 it is 50,003. 2.4.2.1: Change Node_Offset Value If you need to, you can change the default Node_Offset from 50,000 to any number between 1 and 4,194,302 using the GUI Configurator (see Section 1.9). Follow these instructions: Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-6 2: Using the ProtoCom/ProtoCom-Lon 1. From the GUI Configurator screen, enter the Node_Offset you want to use. The example screen below is for a ProtoCom configured for BACnet MS/TP protocol. Enter a new Node Offset and click Submit 2. Enter the value you want to use in the Node_Offset field. 3. Click Submit. The BACnet device instances will be set by taking the new Node_Offset and adding it to the Modbus Address that you assigned to the device (Section 2.1). For example, using a Node_Offset changed to 20,000: • If Device 1 has a Modbus Address of 1, Device 2 has a Modbus Address of 2, Device 3 has a Modbus Address of 3; • The Device Instance for Device 1 is 20,001; for Device 2 it is 20,002; and for Device 3 it is 20,003. 2.4.3: Device Node-ID for Metasys N2, Modbus/TCP, and DF1 Protocols The Modbus Addresses that you assigned to the devices attached to the ProtoCom in Section 2.1 will be the Metasy N2, Modbus TCP, and DF1 Node_ID's for the field protocols. You don’t need to set up any other identification. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-7 2: Using the ProtoCom/ProtoCom-Lon 2.5: Step 5: Set the Baud Rate for BACnet MS/TP and DF1 Protocols Use DIP Switches B0 - B3 to set the serial baud rate to match the baud rate provided by the BMS for BACnet MS/TP and DF1. B0 B1 B2 B3 Figure 2.3: B Bank of DIP Switches NOTES: • The baud rate for Metasys N2 protocol is set to 9600: the B bank of DIP Switches is disabled for Metasys N2 on ProtoCom, since they are not needed. • The B bank of DIP switches is disabled for the ProtoCom-Lon. • The default setting of the ProtoCom is 38400. The following table shows the Baud Rate DIP Switch selection. Baud 9600 19200 38400 57600 76800 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions B0 On Off On Off On B1 On Off On Off Off Doc# B2 On Off Off On On B3 Off On On On On E204701 2-8 2: Using the ProtoCom/ProtoCom-Lon 2.6: Step 6 - Connect the ProtoCom/ProtoCom-Lon to the Meter The six pin connector at the bottom of the ProtoCom/ProtoCom-Lon (labeled HOST) is used to connect the ProtoCom to the EIG meter and to the power supply. (See Section 1.5 for detailed information on the ProtoCom/ProtoCom-Lon’s connections). • Pins 1 through 3 are for the meter’s RS485 connection, though the RS485 GND (Pin 3) is not typically connected. • Pins 4 through 6 are for power. CAUTION! DO NOT CONNECT POWER YET. Device Pins Pin RS‐485 + Pin RS‐485 ‐ Pin GND Power In (+) Power In (‐) Frame Ground ProtoCom Pin # Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin assignment RS‐485 + RS‐485 ‐ RS‐485 GND V+ V‐ FRAME GND Figure 2.4: HOST RS485 Connections The EIG meters have the following RS485 connections: • The Shark® meters, the Nexus® meters, and the MP200 Metering System have a two wire RS485 connection that can connect directly to the ProtoCom’s RS485 connections: 1. Connect the meter’s B+ to the ProtoCom/ProtoCom-Lon’s Tx +/- connection. 2. Connect the meter’s A- to the ProtoCom/ProtoCom-Lon’s Rx +/- connection. • The DMMS 425 meter has a four wire RS485 connection. 1. Connect the meter’s R + and T+ wires together, and connect the combined wire to the ProtoCom’s Tx+/-. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-9 2: Using the ProtoCom/ProtoCom-Lon 2. Connect the R- and T- wires together and connect the combined wire to the ProtoCom/ProtoCom-Lon’s Rx +/-. See the diagram below. DMMS 425 Meter RS485 Communications Port G R+ T+ R- T- ProtoCom/ProtoCom-Lon Tx+/Rx+/-Gnd Figure 2.5: Connecting RS485 between DMMS 425 and ProtoCom/ProtoCom-Lon Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-10 2: Using the ProtoCom/ProtoCom-Lon 2.6.1: Biasing the Modbus RS485 Network (only if necessary) An RS485 network with more than one device needs to have biasing to ensure proper communication. The biasing only needs to be done on one device. If necessary, you can set up biasing on the ProtoCom. Refer to Section 1.8 for instructions on removing and replacing the unit’s top cover. The ProtoCom has 530 Ohm resistors that can be used to set the biasing. The default position of the Biasing jumpers is OFF. The OFF position is when the 2 RED biasing jumpers straddle the 4 pins closest to the outside of the board of the ProtoCom. To turn biasing on, move the jumpers to the right so that they straddle the four inside pins. See the figure below. To turn biasing ON, move the red jumper to the right so that it covers these 2 pins Figure 2.6: Biasing Jumpers IMPORTANT! • Only turn biasing ON if the Building Management System (BMS) cannot see more than one device connected to the ProtoCom and you have checked that all of the settings (Modbus COM settings, wiring, and DIP switches) are correct. • Do not touch any other parts of the main board. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-11 2: Using the ProtoCom/ProtoCom-Lon 2.6.2: Set End of Line Termination Switch for the Modbus RS485 Port (only if necessary) On long RS485 cabling runs, the RS485 trunk must be properly terminated at each end. The ProtoCom has a blue End-of-Line (EOL) terminating switch (see the figure below). On short cabling runs the EOL switch does not to need to be turned ON; therefore the default setting for this ProtoCom’s EOL switch is OFF. Refer to Section 1.8 for instructions on removing and replacing the unit’s top cover. If the ProtoCom is placed at one of the ends of the trunk on a long RS485 cabling run, turn the Blue RS485 End-of- Line Terminating switch to the ON position. To turn the EOL switch ON, move the blue jumper down so that it covers these 2 pins Figure 2.7: EOL Termination Jumpers IMPORTANT! Do not touch any other parts of the main board. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-12 2: Using the ProtoCom/ProtoCom-Lon 2.7: Step 7 - Connect to the RS485/LonWorks Network (BACnet MS/TP, Metasys N2, DF1, or LonWorks) BACnet MS/TP, Metasys N2, or DF1: Wire the Field Port to the RS485 Network Connect the BACnet MS/TP or Metasys N2 RS485 network wires to the 3-pin RS485 connector (labeled FIELD) on the top of the ProtoCom, as shown below. BMS RS485 Wiring RS485 + RS485 ‐ ‐ ProtoCom Pin # Pin 1 Pin 2 Pin 3 Pin Assignment RS‐485 + RS‐485 ‐ RS‐485 GND Figure 2.8: FIELD RS485 Wiring NOTE: The RS485 GND (Pin 3) is not typically connected. If the ProtoCom is the last device on the BACnet MS/TP, Metasys N2, or DF1 trunk, the End-Of-Line Termination (EOL) Switch needs to be enabled. See Section 1.8 for instructions on removing and replacing the unit’s top cover. To enable the switch: using a thin, pointed tool, move it to the left, as shown in the diagram below. Push the white rectangle to the left Figure 2.9: EOL Switch Setting Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-13 2: Using the ProtoCom/ProtoCom-Lon ProtoCom-Lon: Wire the Field Port to the LonWorks Network Connect the ProtoCom-Lon to the field network with the LonWorks terminal using a twisted pair non-shielded cable. LonWorks has no polarity. Figure 2.10: LonWorks FIELD Terminal 2.8: Step 8 - Connect Power to the ProtoCom/ProtoCom-Lon Apply power to the ProtoCom/ProtoCom-Lon as show in the figure below. Ensure that the power supply used complies with the specifications provided in Section 1.4. The ProtoCom/ProtoCom-Lon accepts either 9-30VDC or 12-24 VAC on pins 4 and 5. Power Requirement for ProtoCom/ProtoCom‐Lon at 9V through 30 VDC or 12‐24 VAC Current Draw Type ProtoCom Family 12VDC/VAC 24VDC/VAC 30VDC ProtoCom (Typical) 170mA 100mA 80mA ProtoCom (Maximum) 240mA 140mA 100mA ProtoCom‐Lon (Typical) 210mA 100mA 90mA ProtoCom‐Lon (Maximum) 250mA 130mA 100mA Note: These values are ‘nominal’ and a safety margin should be added to the power supply of the host system. A safety margin of 25% is recommended. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-14 2: Using the ProtoCom/ProtoCom-Lon Power to ProtoCom/ ProtoCom‐Lon Power In (+) Power In (‐) Frame Ground ProtoCom/ ProtoCom‐Lon Pin Assignment Pin # Pin 4 Pin 5 Pin 6 V+ V‐ FRAME GND Figure 2.11: Connecting Power to the ProtoCom/ProtoCom-Lon 2.9: Step 9 - Turn Off Auto-discovery After Completion to Save Configuration The S3 DIP Switch for enabling Auto-discovery was set in step 3, Section 2.3. Once power is applied to a ProtoCom/ProtoCom-Lon that is set to enable Auto-discovery, the unit takes about 3 minutes to complete the discovery of all of the EIG meters attached to the ProtoCom/ProtoCom-Lon and the loading of their data points. Once the ProtoCom/ProtoCom-Lon has discovered all of the connected EIG meters, set the S3 DIP switch to the OFF position to save the current configuration. The OFF position is when the DIP switches are set closest to the outside of the box. ProtoCom/ProtoCom‐Lon S3 DIP Switch Auto‐discovery Mode Auto‐discovery ON – Build New Configuration Auto‐discovery OFF – Save Current Configuration Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 S3 On Off 2-15 2: Using the ProtoCom/ProtoCom-Lon 2.10: Step 10: Additional Configuration Depending on the protocol being used and the specific needs of your application, you may use the following configuration instructions. 2.10.1: Use the Web GUI to Configure IP Address for BACnet IP and EtherNet/IP Follow the instructions in Section 1.9 to connect to the ProtoCom via its Ethernet port and to bring up the Web GUI. NOTE: Below the Active Profiles heading you should see profiles listed for connected devices. If no profiles are displayed, check the wiring, baud rate, and DIP switch settings, because there is a problem with device communication. All the active profiles must show the correct Addresses before proceeding. Connected devices found through Auto-Discovery Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-16 2: Using the ProtoCom/ProtoCom-Lon Set the IP Address for Field Network (BACnet/IP, Modbus TCP, and Ethernet/IP Only): 1. From the Web Configurator page, click the Diagnostics & Debugging button in the bottom right side of the page. Click this button BACnet/IP Configurator Webpage Click this button Ethernet/IP Configurator Webpage Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-17 2: Using the ProtoCom/ProtoCom-Lon 2. Under Navigation, on the left side of the screen, click Setup>Network Settings. 3. The current network settings are shown in the screen. Enter new IP address here 4. Modify the IP address (N1 IP address field) of the ProtoCom’s Ethernet port. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-18 2: Using the ProtoCom/ProtoCom-Lon 5. If necessary, change the Netmask (N1 Netmask field) by entering a new Subnet Mask. 6. If necessary, change the IP Gateway (Default Gateway field) by entering a new IP Gateway. NOTE: If the ProtoCom is connected to a router, the IP Gateway of the ProtoCom should be set to the IP address of the router. 7. Reset the ProtoCom by clicking the System Restart button at the bottom of the page. 8. Unplug the Ethernet cable from the PC and connect it to the network hub or router. 9. Record the IP address you assigned to the ProtoCom and store it in a safe place. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-19 2: Using the ProtoCom/ProtoCom-Lon 2.10.2: Set Up a Password The ProtoCom/ProtoCom-Lon comes with password disabled, but you can easily configure a password for it. There are 2 password access levels: • Admin: the Admin account has unrestricted access to the unit. • User: the User account can view any ProtoCom/ProtoCom-Lon information, but cannot make any changes to settings or restart the unit. 1. Type the IP address of the ProtoCom/ProtoCom-Lon into your PC’s browser. Click this button 2. From the Web Configurator landing page, click the Diagnostics & Debugging button on the bottom right side of the page to access the FST Web GUI. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-20 2: Using the ProtoCom/ProtoCom-Lon 3. From the navigation tree on the left side of the page, click Setup>Passwords. 4. From the pull-down menu, select Admin or User to set the password for that account. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-21 2: Using the ProtoCom/ProtoCom-Lon 5. Enter the current password (if there is one) and the new password in both the New Password and Confirm New Password fields. The password must be a minimum of eight characters; it is case sensitive. Be sure to write down the password and store it in a safe place. 6. Click Update Password to save your changes. 7. Repeat the process for the other account, if desired. 8. You can close the browser window. NOTE: You can disable an active password by leaving the New Password and Confirm New Password fields blank and then clicking the Update Password button. 2.10.3: Configure the ProtoCom-Lon Following are instructions specific to the ProtoCom-Lon configuration. Commission the ProtoCom-Lon on a LonWorks Network Commissioning can only be performed by the LonWorks administrator. The user will be prompted by the LonWorks Administrator to activate the Service Pin on the ProtoCom-Lon at the correct step of the commissioning process, which varies for each LonWorks Network Management Tool. Figure 2.12: Location of ProtoCom-Lon Service Pin Instructions Upload an XIF File from the ProtoCom-Lon Using the Using the Web GUI You may need an XIF file. If so, first follow the instructions in Section 1.9 to connect to the ProtoCom-Lon via its Ethernet port. Open a web browser and go to the following address: IP address of ProtoCessor/fserver.xif Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-22 2: Using the ProtoCom/ProtoCom-Lon For example: 192.168.1.24/fserver.xif If the web browser prompts you to save the file, save it to the PC. If the web browser displays the xif file as a web page (see the example shown below), right-click in the page and save the file to your PC as fserver.xif. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-23 2: Using the ProtoCom/ProtoCom-Lon 2.11: Step 11 - Use the CAS BACnet Explorer to Validate the ProtoCom in the Field (BACnet MS/TP or BACnet/IP) When you purchase a ProtoCom from EIG, you receive a complementary 2 week, fully functional copy of CAS BACnet Explorer (through Chipkin Automation) that can be used to validate BACnet MS/TP and/or BACnet/IP communications in the field without having to have the BMS Integrator on site. NOTE: To test BACnet MS/TP you will need a Serial to RS485 or a USB to RS485 converter. Download the CAS Explorer and Request an Activation Key To request the complementary BACnet CAS key: 1. Go to http://app.chipkin.com/activation/twoweek/. 2. Fill in all the information and enter "Electro2013" in the Vendor Code field. 3. The key will be sent to the email address you entered. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-24 2: Using the ProtoCom/ProtoCom-Lon 4. Once you receive the email with the activation key, go to http://www.chipkin.com/ technical-resources/cas-bacnet-explorer/. 5.. Scroll down until you see the Download icon. 6. Click Executable (dmb) and run the file. A Setup Wizard will step you through downloading the CAS Bacnet Explorer application. 7. Follow the prompts. When you finish installation a window will prompt you to enter a license. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-25 2: Using the ProtoCom/ProtoCom-Lon 8. When you click OK, you will see the screen below. 9. Enter your email address and paste the activation key that was sent to your email. 10. Click the Activate button to begin your two week free trial. 2.11.1: CAS BACnet Setup Following is an example of how to configure the ProtoCom with a BACnet Explorer. The one shown here was developed by Chipkin Automation Systems. It is subject to all of their licenses and restrictions. Please read and follow their license requirements before using. These are the instructions to set up CAS BACnet Explorer for the first time on BACnet MS/ST and BACnet/IP. CAS BACnet MS/TP Setup 1. Using the Serial to RS485 or USB to RS485 converter, connect it to your PC and the 3 Pin BACnet MS/TP connector on the ProtoCom (the FIELD connector). Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-26 2: Using the ProtoCom/ProtoCom-Lon 2. Open the CAS BACnet Explorer application to display the main screen. 3. Click on Settings. 4. In the Networks section, check the BACnet MSTP box and uncheck the BACnet/IP and BACnet Ethernet boxes. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-27 2: Using the ProtoCom/ProtoCom-Lon 5. Set the BACnet MSTP MAC address to 0. 6. Set the BACnet MSTP Baud Rate to 38400. 7. Click OK. 3. In the bottom right-hand corner of the main screen, make sure that the BACnet MSTP box is green. 4. Click on Discover. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-28 2: Using the ProtoCom/ProtoCom-Lon 5. Check all 4 boxes. 6. Click Send. The screen will display BACnet network information. CAS BACnet/IP Setup 1. See Section 1.9 to set the IP address and subnet of the PC that will be running the CAS BACnet Explorer. 2. Connect a straight or crossover Ethernet cable from the PC to the ProtoCom. 3. Open the CAS BACnet Explorer application to display the main screen. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-29 2: Using the ProtoCom/ProtoCom-Lon 4. Click on Settings. 5. In the Networks section, check the BACnet/IP box and uncheck the BACnet MSTP and BACnet Ethernet boxes. 6. In the Select a Network Device box, select the PC’s network card by clicking on it. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-30 2: Using the ProtoCom/ProtoCom-Lon 7. Click OK. 4. In the bottom right-hand corner of the screen, make sure that the BACnet/IP box is green. 5. Click on Discover. 6. Check all 4 boxes. 7. Click Send. The screen will display BACnet network information. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-31 2: Using the ProtoCom/ProtoCom-Lon This page intentionally left blank. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 2-32 3: Device Communication 3: Device Communication The ProtoCom/ProtoCom-Lon has LEDs that indicate communication between the device and both the EIG meters and other devices it is connected to. The LEDs can be used to diagnose communication problems. 3.1: LED Diagnostics for Modbus RTU Communications Between ProtoCom/ProtoCom-Lon and Devices The diagram below shows the unit’s LED Locations. Figure 3.1: ProtoCom/ProtoCom-Lon LEDs The table below describes the action of the LEDs. Tag SPL RUN ERR RX TX PWR Description The SPL LED is lit if the ProtoCom/ProtoCom‐Lon is offline. The RUN LED starts flashing 20 seconds after power up, indicating normal operation. The SYS ERR LED will be solidly lit 15 seconds after power up, and will turn off after 5 seconds. A steady red light after that time indicates there is a system error on the ProtoCom/ProtoCom‐Lon. If this occurs, check the Web GUI Error screen and report the “system error” shown in the screen to EIG’s Technical Support for analysis. The RX LED flashes when a message is received on the Host port. The TX LED flashes when a message is sent on the Host port. This is the power light that should show steady green at all times when the ProtoCom/ProtoCom‐Lon is powered on. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 3-1 3: Device Communication 3.2: Communication Problems Communication problems can be either from the side of the meter communication with the ProtoCom/ProtoCom-Lon or the ProtoCom/ProtoCom-Lon’s communication with the field device. 3.2.1: No Communication on Modbus RTU (Meter) Side If the TX/RX LEDs are not flashing rapidly, there is a communication problem on the Modbus (Meter) side. Check the following items: • The action of the ProtoCom/ProtoCom-Lon LEDs - see the table on page 3-1 • That the baud rate, parity, data bits, and stop bits are set correctly • That the Modbus device address is correct • That the wiring is correct - see chapters 1 and 2 • That all of the Modbus RTU devices were discovered in the Web Configurator (see Section 2.10.1) 3.2.2: Field Communication Problems To diagnose field communication problems, check the following items: • The action of the ProtoCom/ProtoCom-Lon LEDs - see the table on page 3-1 • That the DIP switch settings for baud rate and device instance are correct - see sections 2.4 and 2.5 • That the IP address setting is correct • That the wiring is correct - see chapters 1 and 2 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 3-2 A: Protocol Data Points for EIG Meters A: Protocol Data Points for EIG Meters Lists of the protocol data points for the supported EIG meters begins on the next page. Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 A-1 A: Protocol Data Points for EIG Meters A.1: Shark® 100 Meter PointName VoltsAͲN VoltsBͲN VoltsCͲN VoltsAͲB VoltsBͲC VoltsCͲA AmpsA AmpsB AmpsC Watts3ͲPhtotal VARs3ͲPhtotal VAs3ͲPhtotal PowerFactor3ͲPhtotal Frequency NeutralCurrent WͲhoursReceived WͲhoursDelivered WͲhoursNet WͲhoursTotal VARͲhoursPositive VARͲhoursNegative VARͲhoursNet VARͲhoursTotal VAͲhoursTotal PositiveWatts3ͲPhAvg PositiveVARs3ͲPhAvg NegativeWatts3ͲPhAvg NegativeVARs3ͲPhAvg VAs3ͲPhAvg PositivePF3ͲPhAvg NegativePF3ͲPFAvg BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Doc# E204701 EIPTag Name Flt_XXX[0] Flt_XXX[1] Flt_XXX[2] Flt_XXX[3] Flt_XXX[4] Flt_XXX[5] Flt_XXX[6] Flt_XXX[7] Flt_XXX[8] Flt_XXX[9] Flt_XXX[10] Flt_XXX[11] Flt_XXX[12] Flt_XXX[13] Flt_XXX[14] S32_XXX[0] S32_XXX[1] S32_XXX[2] S32_XXX[3] S32_XXX[4] S32_XXX[5] S32_XXX[6] S32_XXX[7] S32_XXX[8] Flt_XXX[15] Flt_XXX[16] Flt_XXX[17] Flt_XXX[18] Flt_XXX[19] Flt_XXX[20] Flt_XXX[21] DF1 Address F10:0 F10:1 F10:2 F10:3 F10:4 F10:5 F10:6 F10:7 F10:8 F10:9 F10:10 F10:11 F10:12 F10:13 F10:14 F11:0 F11:1 F11:2 F11:3 F11:4 F11:5 F11:6 F11:7 F11:8 F10:15 F10:16 F10:17 F10:18 F10:19 F10:20 F10:21 LonName nvoVoltsAN_XXX nvoVoltsBN_XXX nvoVoltsCN_XXX nvoVoltsAB_XXX nvoVoltsBC_XXX nvoVoltsCA_XXX nvoAmpsA_XXX nvoAmpsB_XXX nvoAmpsC_XXX nvoWatt3PhTo_XXX nvoVAR3PhTot_XXX nvoVA3PhTot_XXX nvoPF3PhTot_XXX nvoFreq_XXX nvoNeutCurr_XXX nvoWh_Rec_XXX nvoWh_Del_XXX nvoWh_Net_XXX nvoWh_Tot_XXX nvoVARh_Pos_XXX nvoVARh_Neg_XXX nvoVARh_Net_XXX nvoVARh_Tot_XXX nvoVAh_Tot_XXX nvoPsWt3PhAv_XXX nvoPsVAR3PhA_XXX nvoNgWt3PhAv_XXX nvoNgVAR3PhA_XXX nvoVA3Ph_Avg_XXX nvoPsPF3PhAv_XXX nvoNgPF3PhAv_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-2 A: Protocol Data Points for EIG Meters PointName PositiveWatts3ͲPhMaxAvgDemand PositiveVARs3ͲPhMaxAvgDemand NegativeWatts3ͲPhMaxAvgDemand NegativeVARs3ͲPhMaxAvgDemand VoltsAͲN%THD VoltsBͲN%THD VoltsCͲN%THD AmpsA%THD AmpsB%THD AmpsC%THD MeterStatus CTmultiplier CTdenominator CTnumerator PTnumerator PTdenominator PThookup PTmultiplier SerialNumberReg1 SerialNumberReg2 SerialNumberReg3 SerialNumberReg4 SerialNumberReg5 SerialNumberReg6 SerialNumberReg7 SerialNumberReg8 PasswordforResetinuse PasswordforConfigurationinuse BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BI BI BACnet Object ID 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI DI DI N2 Point Address 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 EIPTag Name Flt_XXX[22] Flt_XXX[23] Flt_XXX[24] Flt_XXX[25] Dev_XXX[0] Dev_XXX[1] Dev_XXX[2] Dev_XXX[3] Dev_XXX[4] Dev_XXX[5] Byt_XXX[0] Byt_XXX[1] Byt_XXX[2] Dev_XXX[8] Dev_XXX[9] Dev_XXX[10] Byt_XXX[3] Byt_XXX[4] Dev_XXX[12] Dev_XXX[13] Dev_XXX[14] Dev_XXX[15] Dev_XXX[16] Dev_XXX[17] Dev_XXX[18] Dev_XXX[19] Byt_XXX[5] Byt_XXX[6] DF1 Address F10:22 F10:23 F10:24 F10:25 N12:0 N12:1 N12:2 N12:3 N12:4 N12:5 N13:0 N13:1 N13:2 N12:8 N12:9 N12:10 N13:3 N13:4 N12:12 N12:13 N12:14 N12:15 N12:16 N12:17 N12:18 N12:19 N13:5 N13:6 LonName nvoPWt3PMADm_XXX nvoPVAR3PMAD_XXX nvoNWt3PMADm_XXX nvoNVAR3PMAD_XXX nvoVltAN_THD_XXX nvoVltBN_THD_XXX nvoVltCN_THD_XXX nvoAmpA_THD_XXX nvoAmpB_THD_XXX nvoAmpC_THD_XXX nvoMtrStat_XXX nvoCT_mult_XXX nvoCT_den_XXX nvoCT_num_XXX nvoPT_num_XXX nvoPT_den_XXX nvoPT_hookup_XXX nvoPT_mult_XXX nvoSerNum1_XXX nvoSerNum2_XXX nvoSerNum3_XXX nvoSerNum4_XXX nvoSerNum5_XXX nvoSerNum6_XXX nvoSerNum7_XXX nvoSerNum8_XXX nvoPswdReset_XXX nvoPswdCnfg_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_lev_percent SNVT_lev_percent SNVT_lev_percent SNVT_lev_percent SNVT_lev_percent SNVT_lev_percent SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 A-3 A: Protocol Data Points for EIG Meters A.2: Shark® 200 Meter PointName VoltsAͲN VoltsBͲN VoltsCͲN VoltsAͲB VoltsBͲC VoltsCͲA AmpsA AmpsB AmpsC Watts3ͲPhtotal VARs3ͲPhtotal VAs3ͲPhtotal PowerFactor3ͲPhtotal Frequency NeutralCurrent WattsPhaseA WattsPhaseB WattsPhaseC VARsPhaseA VARsPhaseB VARsPhaseC VAsPhaseA VAsPhaseB VAsPhaseC PowerFactorPhaseA PowerFactorPhaseB PowerFactorPhaseC WͲhoursReceived WͲhoursDelivered WͲhoursNet WͲhoursTotal VARͲhoursPositive VARͲhoursNegative BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Doc# E204701 EIPTag Name Flt_XXX[0] Flt_XXX[1] Flt_XXX[2] Flt_XXX[3] Flt_XXX[4] Flt_XXX[5] Flt_XXX[6] Flt_XXX[7] Flt_XXX[8] Flt_XXX[9] Flt_XXX[10] Flt_XXX[11] Flt_XXX[12] Flt_XXX[13] Flt_XXX[14] Flt_XXX[15] Flt_XXX[16] Flt_XXX[17] Flt_XXX[18] Flt_XXX[19] Flt_XXX[20] Flt_XXX[21] Flt_XXX[22] Flt_XXX[23] Flt_XXX[24] Flt_XXX[25] Flt_XXX[26] S32_XXX[0] S32_XXX[1] S32_XXX[2] S32_XXX[3] S32_XXX[4] S32_XXX[5] DF1 Address F10:0 F10:1 F10:2 F10:3 F10:4 F10:5 F10:6 F10:7 F10:8 F10:9 F10:10 F10:11 F10:12 F10:13 F10:14 F10:15 F10:16 F10:17 F10:18 F10:19 F10:20 F10:21 F10:22 F10:23 F10:24 F10:25 F10:26 F11:0 F11:1 F11:2 F11:3 F11:4 F11:5 LonName nvoVolts_AN_XXX nvoVolts_BN_XXX nvoVolts_CN_XXX nvoVolts_AB_XXX nvoVolts_BC_XXX nvoVolts_CA_XXX nvoAmps_A_XXX nvoAmps_B_XXX nvoAmps_C_XXX nvoWatt3PhTo_XXX nvoVAR3PhTot_XXX nvoVA_3PhTot_XXX nvoPF_3PhTot_XXX nvoFreq_XXX nvoNeut_Crnt_XXX nvoWatts_PhA_XXX nvoWatts_PhB_XXX nvoWatts_PhC_XXX nvoVARs_PhA_XXX nvoVARs_PhB_XXX nvoVARs_PhC_XXX nvoVAs_PhA_XXX nvoVAs_PhB_XXX nvoVAs_PhC_XXX nvoPF_PhA_XXX nvoPF_PhB_XXX nvoPF_PhC_XXX nvoWh_Rec_XXX nvoWh_Del_XXX nvoWh_Net_XXX nvoWh_Tot_XXX nvoVARh_Pos_XXX nvoVARh_Neg_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-4 A: Protocol Data Points for EIG Meters PointName VARͲhoursNet VARͲhoursTotal AmpsAAvg AmpsBAvg AmpsCAvg PositiveWatts3ͲPhAvg PositiveVARs3ͲPhAvg NegativeWatts3ͲPhAvg NegativeVARs3ͲPhAvg VAs3ͲPhAvg PositivePF3ͲPhAvg NegativePF3ͲPFAvg VAͲhoursTotal MeterStatus CurrentDate&TimeReg1 CurrentDate&TimeReg2 CurrentDate&TimeReg3 PositiveWatts3ͲPhMaxAvgDemand PositiveVARs3ͲPhMaxAvgDemand NegativeWatts3ͲPhMaxAvgDemand NegativeVARs3ͲPhMaxAvgDemand CTmultiplier CTdenominator CTnumerator PTnumerator PTdenominator PThookup PTmultiplier SerialNumberReg1 SerialNumberReg2 SerialNumberReg3 SerialNumberReg4 SerialNumberReg5 SerialNumberReg6 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 Doc# E204701 EIPTag Name S32_XXX[6] S32_XXX[7] Flt_XXX[27] Flt_XXX[28] Flt_XXX[29] Flt_XXX[30] Flt_XXX[31] Flt_XXX[32] Flt_XXX[33] Flt_XXX[34] Flt_XXX[35] Flt_XXX[36] S32_XXX[8] Byt_XXX[0] Dev1_XXX[0] Dev1_XXX[1] Dev1_XXX[2] Flt_XXX[37] Flt_XXX[38] Flt_XXX[39] Flt_XXX[40] Byt_XXX[1] Byt_XXX[2] Dev2_XXX[0] Dev2_XXX[1] Dev2_XXX[2] Byt_XXX[3] Byt_XXX[4] Dev2_XXX[4] Dev2_XXX[5] Dev2_XXX[6] Dev2_XXX[7] Dev2_XXX[8] Dev2_XXX[9] DF1 Address F11:6 F11:7 F10:27 F10:28 F10:29 F10:30 F10:31 F10:32 F10:33 F10:34 F10:35 F10:36 F11:8 N14:0 N12:0 N12:1 N12:2 F10:37 F10:38 F10:39 F10:40 N14:1 N14:2 N13:0 N13:1 N13:2 N14:3 N14:4 N13:4 N13:5 N13:6 N13:7 N13:8 N13:9 LonName nvoVARh_Net_XXX nvoVARh_Tot_XXX nvoAmpA_Avg_XXX nvoAmpB_Avg_XXX nvoAmpC_Avg_XXX nvoPsWat3PAv_XXX nvoPsVAR3PAv_XXX nvoNgWat3PAv_XXX nvoNgVAR3PAv_XXX nvoVA_3PhAvg_XXX nvoPsPF3PhAv_XXX nvoNgPF3PhAv_XXX nvoVAh_Tot_XXX nvoMtr_Stat_XXX nvoCurDatTm1_XXX nvoCurDatTm2_XXX nvoCurDatTm3_XXX nvoPWt3PMADm_XXX nvoPVr3PMADm_XXX nvoNWt3PMADm_XXX nvoNVr3PMADm_XXX nvoCT_mult_XXX nvoCT_den_XXX nvoCT_num_XXX nvoPT_num_XXX nvoPT_den_XXX nvoPT_hookup_XXX nvoPT_mult_XXX nvoSerNum1_XXX nvoSerNum2_XXX nvoSerNum3_XXX nvoSerNum4_XXX nvoSerNum5_XXX nvoSerNum6_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count A-5 A: Protocol Data Points for EIG Meters SerialNumberReg7 BACnet BACnet N2 Object Object Data Type ID Type AI 68 AI SerialNumberReg8 AI 69 AI PasswordforResetinuse PasswordforConfigurationinuse BI BI 70 71 DI DI PointName N2 EIPTag Point Name Address 68 Dev2_XXX[1 0] 69 Dev2_XXX[1 1] 70 Byt_XXX[5] 71 Byt_XXX[6] DF1 Address LonName LonSNVT N13:10 nvoSerNum7_XXX SNVT_count N13:11 nvoSerNum8_XXX SNVT_count N14:5 N14:6 nvoPswdReset_XXX nvoPswdCnfg_XXX SNVT_count SNVT_count Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 A-6 A: Protocol Data Points for EIG Meters A.3: Nexus® 1252/1262/1272 Meters PointName CurrentTimeReg1 CurrentTimeReg2 CurrentTimeReg3 CurrentTimeReg4 OnesecPhaseAͲNVoltage OnesecPhaseBͲNVoltage OnesecPhaseCͲNVoltage OnesecPhaseACurrent OnesecPhaseBCurrent OnesecPhaseCCurrent OnesecNeutralCurrentMeasured OnesecNeutralCurrentCalculated OnesecPhaseAͲBVoltage OnesecPhaseBͲCVoltage OnesecPhaseCͲAVoltage OnesecThreePhaseVA OnesecThreePhaseVAR OnesecWatts OnesecFrequency OnesecThreePhasePF PhaseAͲNVoltageTHD PhaseBͲNVoltageTHD PhaseCͲNVoltageTHD PhaseACurrentTHD PhaseBCurrentTHD PhaseCCurrentTHD BlockWindowAvgVA BlockWindowAvgVAR BlockWindowAvgWatt MaxBlockWindowAvgPosVA MaxBlockWindowAvgPosVAR MaxBlockWindowAvgNegVAR MaxBlockWindowAvgPosWatt BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Doc# E204701 EIPTag Name Dev1_XXX[0] Dev1_XXX[1] Dev1_XXX[2] Dev1_XXX[3] S32_XXX[0] S32_XXX[1] S32_XXX[2] S32_XXX[3] S32_XXX[4] S32_XXX[5] S32_XXX[6] S32_XXX[7] S32_XXX[8] S32_XXX[9] S32_XXX[10] S32_XXX[11] S32_XXX[12] S32_XXX[13] S32_XXX[14] Dev2_XXX[0] Dev2_XXX[1] Dev2_XXX[2] Dev2_XXX[3] Dev2_XXX[4] Dev2_XXX[5] Dev2_XXX[6] S32_XXX[15] S32_XXX[16] S32_XXX[17] S32_XXX[18] S32_XXX[19] S32_XXX[20] S32_XXX[21] DF1 Address N12:0 N12:1 N12:2 N12:3 F10:0 F10:1 F10:2 F10:3 F10:4 F10:5 F10:6 F10:7 F10:8 F10:9 F10:10 F10:11 F10:12 F10:13 F10:14 N13:0 N13:1 N13:2 N13:3 N13:4 N13:5 N13:6 F10:15 F10:16 F10:17 F10:18 F10:19 F10:20 F10:21 LonName nvoCurTime1_XXX nvoCurTime2_XXX nvoCurTime3_XXX nvoCurTime4_XXX nvoPhAN_Volt_XXX nvoPhBN_Volt_XXX nvoPhCN_Volt_XXX nvoPhA_Curr_XXX nvoPhB_Curr_XXX nvoPhC_Curr_XXX nvoNtCurMeas_XXX nvoNtCurMalc_XXX nvoPhAB_Volt_XXX nvoPhBC_Volt_XXX nvoPhCA_Volt_XXX nvo3PhVA_XXX nvo3PhVAR_XXX nvoWatts_XXX nvo1Freq_XXX nvo3PhPF_XXX nvoVoltANTHD_XXX nvoVoltBNTHD_XXX nvoVoltCNTHD_XXX nvoCurrATHD_XXX nvoCurrBTHD_XXX nvoCurrCTHD_XXX nvoBlWdAvVA_XXX nvoBlWdAvVAR_XXX nvoBlWdAvWat_XXX nvoMBlWdAvVA_XXX nvoMBWAvPVAR_XXX nvoMBWAvNVAR_XXX nvoMBWAvPWat_XXX LonSNVT SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-7 A: Protocol Data Points for EIG Meters PointName MaxBlockWindowAvgNegWatt TotalVAh(Quad1Ͳ4)ScaledPrimary PosVARh(Quad1+2)ScaledPrimary NegVARh(Quad3+4)ScaledPrimary PosWh(Quad1+4)ScaledPrimary NegWh(Quad2+3)ScaledPrimary CTNumerator CTDenominator PTNumerator PTDenominator SystemHookup PasswordState CommDeviceStatus DSPDeviceStatus SerialNumber BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Doc# E204701 EIPTag Name S32_XXX[22] S32_XXX[23] S32_XXX[24] S32_XXX[25] S32_XXX[26] S32_XXX[27] S32_XXX[27] S32_XXX[28] S32_XXX[29] S32_XXX[30] Dev3_XXX[0] Dev3_XXX[1] Dev3_XXX[2] Dev3_XXX[3] U32_XXX[0] DF1 Address F10:22 F10:23 F10:24 F10:25 F10:26 F10:27 F10:27 F10:28 F10:29 F10:30 N14:0 N14:1 N14:2 N14:3 F11:0 LonName nvoMBWAvNWat_XXX nvoTVAhQ14SP_XXX nvoPVARQ12SP_XXX nvoNVARQ34SP_XXX nvoPWhQ14ScP_XXX nvoNWhQ23ScP_XXX nvoCT_num_XXX nvoCT_den_XXX nvoPT_num_XXX nvoPT_den_XXX nvoSysHookup_XXX nvoPass_Stat_XXX nvoComDevSt_XXX nvoDSPDevSt_XXX nvoSerNum_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count_inc_f A-8 A: Protocol Data Points for EIG Meters A.4: DMMS 425 Meter PointName InstVoltAN InstVoltBN InstVoltCN InstVoltAB InstVoltBC InstVoltCA InstAmpA InstAmpB InstAmpC InstWatt InstVar InstVa InstPf InstFreq MaxVoltAN MaxVoltBN MaxVoltCN MaxVoltAB MaxVoltBC MaxVoltCA MaxAmpA MaxAmpB MaxAmpC MaxWatt MaxVar MaxVa MaxPf MaxFreq WattHourBlock1 WattHourBlock2 WattHourBlock3 WattHourBlock4 WattHourBlock5 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Doc# E204701 EIPTag Name S16_XXX[0] S16_XXX[1] S16_XXX[2] S16_XXX[3] S16_XXX[4] S16_XXX[5] S16_XXX[6] S16_XXX[7] S16_XXX[8] S16_XXX[9] S16_XXX[10] S16_XXX[11] S16_XXX[12] S16_XXX[13] S16_XXX[14] S16_XXX[15] S16_XXX[16] S16_XXX[17] S16_XXX[18] S16_XXX[19] S16_XXX[20] S16_XXX[21] S16_XXX[22] S16_XXX[23] S16_XXX[24] S16_XXX[25] S16_XXX[26] S16_XXX[27] Dev_XXX[0] Dev_XXX[1] Dev_XXX[2] Dev_XXX[3] Dev_XXX[4] DF1 Address N10:0 N10:1 N10:2 N10:3 N10:4 N10:5 N10:6 N10:7 N10:8 N10:9 N10:10 N10:11 N10:12 N10:13 N10:14 N10:15 N10:16 N10:17 N10:18 N10:19 N10:20 N10:21 N10:22 N10:23 N10:24 N10:25 N10:26 N10:27 N11:0 N11:1 N11:2 N11:3 N11:4 LonName nvoVolt_AN_XXX nvoVolt_BN_XXX nvoVolt_CN_XXX nvoVolt_AB_XXX nvoVolt_BC_XXX nvoVolt_CA_XXX nvoAmp_A_XXX nvoAmp_B_XXX nvoAmp_C_XXX nvoWatt_XXX nvoVar_XXX nvoVa_XXX nvoPf_XXX nvoFreq_XXX nvoMaxVoltAN_XXX nvoMaxVoltBN_XXX nvoMaxVoltCN_XXX nvoMaxVoltAB_XXX nvoMaxVoltBC_XXX nvoMaxVoltCA_XXX nvoMaxAmp_A_XXX nvoMaxAmp_B_XXX nvoMaxAmp_C_XXX nvoMaxWatt_XXX nvoMaxVar_XXX nvoMaxVa_XXX nvoMaxPf_XXX nvoMaxFreq_XXX nvoWh_Blk1_XXX nvoWh_Blk2_XXX nvoWh_Blk3_XXX nvoWh_Blk4_XXX nvoWh_Blk5_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count A-9 A: Protocol Data Points for EIG Meters BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI PointName WattHourBlock6 WattHourBlock7 WattHourBlock8 VarHourBlock1 VarHourBlock2 VarHourBlock3 VarHourBlock4 VarHourBlock5 VarHourBlock6 VarHourBlock7 VarHourBlock8 CTRatio PTRatio BACnet Object ID 34 35 36 37 38 39 40 41 42 43 44 45 46 N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 34 35 36 37 38 39 40 41 42 43 44 45 46 EIPTag Name Dev_XXX[5] Dev_XXX[6] Dev_XXX[7] Dev_XXX[8] Dev_XXX[9] Dev_XXX[10] Dev_XXX[11] Dev_XXX[12] Dev_XXX[13] Dev_XXX[14] Dev_XXX[15] Dev_XXX[16] Dev_XXX[17] DF1 Address N11:5 N11:6 N11:7 N11:8 N11:9 N11:10 N11:11 N11:12 N11:13 N11:14 N11:15 N11:16 N11:17 LonName nvoWh_Blk6_XXX nvoWh_Blk7_XXX nvoWh_Blk8_XXX nvoVARh_Blk1_XXX nvoVARh_Blk2_XXX nvoVARh_Blk3_XXX nvoVARh_Blk4_XXX nvoVARh_Blk5_XXX nvoVARh_Blk6_XXX nvoVARh_Blk7_XXX nvoVARh_Blk8_XXX nvoCT_Ratio_XXX nvoPT_Ratio_XXX LonSNVT SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count A.5: Nexus® 1500 Meter Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 A-10 A: Protocol Data Points for EIG Meters A.5: Nexus® 1500 Meter PointName CurrentTimeReg1 CurrentTimeReg2 CurrentTimeReg3 CurrentTimeReg4 1secPhAͲNVoltage 1secPhBͲNVoltage 1secPhCͲNVoltage 1secVauxVoltage 1secPhACurrent 1secPhBCurrent 1secPhCCurrent 1secMeasuredNeutralCurrent 1secCalculatedNeutralCurrent 1secPhAͲBVoltage 1secPhBͲCVoltage 1secPhCͲAVoltage 1secVA 1secThreeVAR 1secWatts 1secFrequency 1secThreePhPowerFactor PhAͲN/PhAͲBVoltageTHD PhBͲN/PhBͲCVoltageTHD PhCͲN/PhCͲAVoltageTHD PhACurrentTHD PhBCurrentTHD PhCCurrentTHD BlkWindowAvgVA BlkWindowAvgVAR BlkWindowAvgWatt MaxBlkWindowAvgVA MaxBlkWindowAvgPosVAR MaxBlkWindowAvgNegVAR BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Doc# E204701 EIPTag Name Dev1_XXX[0] Dev1_XXX[1] Dev1_XXX[2] Dev1_XXX[3] S32_XXX[0] S32_XXX[1] S32_XXX[2] S32_XXX[3] S32_XXX[4] S32_XXX[5] S32_XXX[6] S32_XXX[7] S32_XXX[8] S32_XXX[9] S32_XXX[10] S32_XXX[11] S32_XXX[12] S32_XXX[13] S32_XXX[14] S32_XXX[15] Dev2_XXX[0] S16_XXX[0] S16_XXX[1] S16_XXX[2] S16_XXX[3] S16_XXX[4] S16_XXX[5] S32_XXX[16] S32_XXX[17] S32_XXX[18] S32_XXX[19] S32_XXX[20] S32_XXX[21] DF1 Address N13:0 N13:1 N13:2 N13:3 F10:0 F10:1 F10:2 F10:3 F10:4 F10:5 F10:6 F10:7 F10:8 F10:9 F10:10 F10:11 F10:12 F10:13 F10:14 F10:15 N14:0 N11:0 N11:1 N11:2 N11:3 N11:4 N11:5 F10:16 F10:17 F10:18 F10:19 F10:20 F10:21 LonName nvoCurTime1_XXX nvoCurTime2_XXX nvoCurTime3_XXX nvoCurTime4_XXX nvoAN_Volt_XXX nvoBN_Volt_XXX nvoCN_Volt_XXX nvoVaux_Volt_XXX nvoA_Crnt_XXX nvoB_Crnt_XXX nvoC_Crnt_XXX nvoMeasNtCrn_XXX nvoCalcNtCrn_XXX nvoAB_Volt_XXX nvoBC_Volt_XXX nvoCA_Volt_XXX nvoVA_XXX nvo3_VAR_XXX nvoWatts_XXX nvoFreq_XXX nvo3_PF_XXX nvoANABVlTHD_XXX nvoBNBCVlTHD_XXX nvoCNCAVlTHD_XXX nvoA_CurTHD_XXX nvoB_CurTHD_XXX nvoC_CurTHD_XXX nvoBlWndAvVA_XXX nvoBlWndAVAR_XXX nvoBlWndAvWt_XXX nvoMxBlWdAVA_XXX nvoMBWdAPVAR_XXX nvoMBWdANVAR_XXX LonSNVT SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-11 A: Protocol Data Points for EIG Meters PointName MaxBlkWindowAvgPosWatt MaxBlkWindowAvgNegWatt TotalVAh(Quad1+2+3+4)ScaledPri PosVARh(Quad1+2)ScaledPri NegVARh(Quad3+4)ScaledPri PosWh(Quad1+4)ScaledPri NegWh(Quad2+3)ScaledPri PhCurrentCTRatioNumerator PhCurrentCTRatioDenominator MeasuredNeutralCurrentCTRatioNum MeasuredNeutralCurrentCTRatioDen PhVoltagePTRatioNumerator PhVoltagePTRatioDenominator AuxVoltagePTRatioNumerator AuxVoltagePTRationDenominator SystemHookup Level1/Level2PasswordState SealingSwitchState DeviceStatus SerialNumberReg1 SerialNumberReg2 SerialNumberReg3 SerialNumberReg4 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 EIPTag Name S32_XXX[22] S32_XXX[23] Flt_XXX[0] Flt_XXX[1] Flt_XXX[2] Flt_XXX[3] Flt_XXX[4] S32_XXX[29] S32_XXX[30] S32_XXX[31] S32_XXX[32] S32_XXX[33] S32_XXX[34] S32_XXX[35] S32_XXX[36] Dev3_XXX[0] Dev3_XXX[2] Dev3_XXX[3] Dev3_XXX[4] Dev3_XXX[5] Dev3_XXX[6] Dev3_XXX[7] Dev3_XXX[8] DF1 Address F10:22 F10:23 F12:0 F12:1 F12:2 F12:3 F12:4 F10:29 F10:30 F10:31 F10:32 F10:33 F10:34 F10:35 F10:36 N15:0 N15:2 N15:3 N15:4 N15:5 N15:6 N15:7 N15:8 LonName nvoMBWdAvPWT_XXX nvoMBWdAvNWT_XXX nvoTVAh1234P_XXX nvoPVARhQ12P_XXX nvoNVARhQ34P_XXX nvoPWhQ14ScP_XXX nvoNWhQd23SP_XXX nvoCrtCTRtNm_XXX nvoCrtCTRtDn_XXX nvoMsNtCTRtN_XXX nvoMsNtCTRtD_XXX nvoVtPTRtNum_XXX nvoVtPTRtDen_XXX nvoAxVtPTRtN_XXX nvoAxVtPTRtD_XXX nvoSysHookup_XXX nvoLv1_2PsSt_XXX nvoSlSwState_XXX nvoDevStat_XXX nvoSerNum1_XXX nvoSerNum2_XXX nvoSerNum3_XXX nvoSerNum4_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count SNVT_count_inc_f SNVT_count_inc_f SNVT_count SNVT_count SNVT_count SNVT_count SNVT_count A.6: MP200-Y Metering System Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 A-12 A: Protocol Data Points for EIG Meters A.6: MP200-Y Metering System PointName VoltsAͲN VoltsBͲN VoltsCͲN VoltsAͲB VoltsBͲC VoltsCͲA Frequency MTR01AmpsA MTR01AmpsB MTR01AmpsC MTR01Watts3ͲPhtotal MTR01VARs3ͲPhtotal MTR01VAs3ͲPhtotal MTR01PowerFactor3ͲPhtotal MTR01NeutralCurrent MTR02AmpsA MTR02AmpsB MTR02AmpsC MTR02Watts3ͲPhtotal MTR02VARs3ͲPhtotal MTR02VAs3ͲPhtotal MTR02PowerFactor3ͲPhtotal MTR02NeutralCurrent MTR03AmpsA MTR03AmpsB MTR03AmpsC MTR03Watts3ͲPhtotal MTR03VARs3ͲPhtotal MTR03VAs3ͲPhtotal MTR03PowerFactor3ͲPhtotal MTR03NeutralCurrent MTR04AmpsA MTR04AmpsB BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Point Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 EIPTagName Flt_XXX[000] Flt_XXX[001] Flt_XXX[002] Flt_XXX[003] Flt_XXX[004] Flt_XXX[005] Flt_XXX[006] Flt_XXX[007] Flt_XXX[008] Flt_XXX[009] Flt_XXX[010] Flt_XXX[011] Flt_XXX[012] Flt_XXX[013] Flt_XXX[014] Flt_XXX[015] Flt_XXX[016] Flt_XXX[017] Flt_XXX[018] Flt_XXX[019] Flt_XXX[020] Flt_XXX[021] Flt_XXX[022] Flt_XXX[023] Flt_XXX[024] Flt_XXX[025] Flt_XXX[026] Flt_XXX[027] Flt_XXX[028] Flt_XXX[029] Flt_XXX[030] Flt_XXX[031] Flt_XXX[032] Doc# E204701 DF1 Address F10:000 F10:001 F10:002 F10:003 F10:004 F10:005 F10:006 F10:007 F10:008 F10:009 F10:010 F10:011 F10:012 F10:013 F10:014 F10:015 F10:016 F10:017 F10:018 F10:019 F10:020 F10:021 F10:022 F10:023 F10:024 F10:025 F10:026 F10:027 F10:028 F10:029 F10:030 F10:031 F10:032 LonName nvoVoltsAN_XXX nvoVoltsBN_XXX nvoVoltsCN_XXX nvoVoltsAB_XXX nvoVoltsBC_XXX nvoVoltsCA_XXX nvoFrequency_XXX nvoM1AmpsA_XXX nvoM1AmpsB_XXX nvoM1AmpsC_XXX nvoM1WattTot_XXX nvoM1VARsTot_XXX nvoM1VAsTot_XXX nvoM1PFTot_XXX nvoM1NeutCur_XXX nvoM2AmpsA_XXX nvoM2AmpsB_XXX nvoM2AmpsC_XXX nvoM2WattTot_XXX nvoM2VARsTot_XXX nvoM2VAsTot_XXX nvoM2PFTot_XXX nvoM2NeutCur_XXX nvoM3AmpsA_XXX nvoM3AmpsB_XXX nvoM3AmpsC_XXX nvoM3WattTot_XXX nvoM3VARsTot_XXX nvoM3VAsTot_XXX nvoM3PFTot_XXX nvoM3NeutCur_XXX nvoM4AmpsA_XXX nvoM4AmpsB_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-13 A: Protocol Data Points for EIG Meters PointName MTR04AmpsC MTR04Watts3ͲPhtotal MTR04VARs3ͲPhtotal MTR04VAs3ͲPhtotal MTR04PowerFactor3ͲPhtotal MTR04NeutralCurrent MTR05AmpsA MTR05AmpsB MTR05AmpsC MTR05Watts3ͲPhtotal MTR05VARs3ͲPhtotal MTR05VAs3ͲPhtotal MTR05PowerFactor3ͲPhtotal MTR05NeutralCurrent MTR06AmpsA MTR06AmpsB MTR06AmpsC MTR06Watts3ͲPhtotal MTR06VARs3ͲPhtotal MTR06VAs3ͲPhtotal MTR06PowerFactor3ͲPhtotal MTR06NeutralCurrent MTR07AmpsA MTR07AmpsB MTR07AmpsC MTR07Watts3ͲPhtotal MTR07VARs3ͲPhtotal MTR07VAs3ͲPhtotal MTR07PowerFactor3ͲPhtotal MTR07NeutralCurrent MTR08AmpsA MTR08AmpsB MTR08AmpsC MTR08Watts3ͲPhtotal MTR08VARs3ͲPhtotal BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 EIPTagName Flt_XXX[033] Flt_XXX[034] Flt_XXX[035] Flt_XXX[036] Flt_XXX[037] Flt_XXX[038] Flt_XXX[039] Flt_XXX[040] Flt_XXX[041] Flt_XXX[042] Flt_XXX[043] Flt_XXX[044] Flt_XXX[045] Flt_XXX[046] Flt_XXX[047] Flt_XXX[048] Flt_XXX[049] Flt_XXX[050] Flt_XXX[051] Flt_XXX[052] Flt_XXX[053] Flt_XXX[054] Flt_XXX[055] Flt_XXX[056] Flt_XXX[057] Flt_XXX[058] Flt_XXX[059] Flt_XXX[060] Flt_XXX[061] Flt_XXX[062] Flt_XXX[063] Flt_XXX[064] Flt_XXX[065] Flt_XXX[066] Flt_XXX[067] Doc# E204701 DF1 Address F10:033 F10:034 F10:035 F10:036 F10:037 F10:038 F10:039 F10:040 F10:041 F10:042 F10:043 F10:044 F10:045 F10:046 F10:047 F10:048 F10:049 F10:050 F10:051 F10:052 F10:053 F10:054 F10:055 F10:056 F10:057 F10:058 F10:059 F10:060 F10:061 F10:062 F10:063 F10:064 F10:065 F10:066 F10:067 LonName nvoM4AmpsC_XXX nvoM4WattTot_XXX nvoM4VARsTot_XXX nvoM4VAsTot_XXX nvoM4PFTot_XXX nvoM4NeutCur_XXX nvoM5AmpsA_XXX nvoM5AmpsB_XXX nvoM5AmpsC_XXX nvoM5WattTot_XXX nvoM5VARsTot_XXX nvoM5VAsTot_XXX nvoM5PFTot_XXX nvoM5NeutCur_XXX nvoM6AmpsA_XXX nvoM6AmpsB_XXX nvoM6AmpsC_XXX nvoM6WattTot_XXX nvoM6VARsTot_XXX nvoM6VAsTot_XXX nvoM6PFTot_XXX nvoM6NeutCur_XXX nvoM7AmpsA_XXX nvoM7AmpsB_XXX nvoM7AmpsC_XXX nvoM7WattTot_XXX nvoM7VARsTot_XXX nvoM7VAsTot_XXX nvoM7PFTot_XXX nvoM7NeutCur_XXX nvoM8AmpsA_XXX nvoM8AmpsB_XXX nvoM8AmpsC_XXX nvoM8WattTot_XXX nvoM8VARsTot_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-14 A: Protocol Data Points for EIG Meters PointName MTR08VAs3ͲPhtotal MTR08PowerFactor3ͲPhtotal MTR08NeutralCurrent MTR01WͲhoursReceived MTR01WͲhoursDelivered MTR01WͲhoursNet MTR01WͲhoursTotal MTR01VARͲhoursPositive MTR01VARͲhoursNegative MTR01VARͲhoursNet MTR01VARͲhoursTotal MTR01VAͲhoursTotal MTR02WͲhoursReceived MTR02WͲhoursDelivered MTR02WͲhoursNet MTR02WͲhoursTotal MTR02VARͲhoursPositive MTR02VARͲhoursNegative MTR02VARͲhoursNet MTR02VARͲhoursTotal MTR02VAͲhoursTotal MTR03WͲhoursReceived MTR03WͲhoursDelivered MTR03WͲhoursNet MTR03WͲhoursTotal MTR03VARͲhoursPositive MTR03VARͲhoursNegative MTR03VARͲhoursNet MTR03VARͲhoursTotal MTR03VAͲhoursTotal MTR04WͲhoursReceived MTR04WͲhoursDelivered MTR04WͲhoursNet MTR04WͲhoursTotal MTR04VARͲhoursPositive BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 EIPTagName Flt_XXX[068] Flt_XXX[069] Flt_XXX[070] S32_XXX[000] S32_XXX[001] S32_XXX[002] S32_XXX[003] S32_XXX[004] S32_XXX[005] S32_XXX[006] S32_XXX[007] S32_XXX[008] S32_XXX[009] S32_XXX[010] S32_XXX[011] S32_XXX[012] S32_XXX[013] S32_XXX[014] S32_XXX[015] S32_XXX[016] S32_XXX[017] S32_XXX[018] S32_XXX[019] S32_XXX[020] S32_XXX[021] S32_XXX[022] S32_XXX[023] S32_XXX[024] S32_XXX[025] S32_XXX[026] S32_XXX[027] S32_XXX[028] S32_XXX[029] S32_XXX[030] S32_XXX[031] Doc# E204701 DF1 Address F10:068 F10:069 F10:070 F11:000 F11:001 F11:002 F11:003 F11:004 F11:005 F11:006 F11:007 F11:008 F11:009 F11:010 F11:011 F11:012 F11:013 F11:014 F11:015 F11:016 F11:017 F11:018 F11:019 F11:020 F11:021 F11:022 F11:023 F11:024 F11:025 F11:026 F11:027 F11:028 F11:029 F11:030 F11:031 LonName nvoM8VAsTot_XXX nvoM8PFTot_XXX nvoM8NeutCur_XXX nvoM1WHRec_XXX nvoM1WHDel_XXX nvoM1WHNet_XXX nvoM1WHTot_XXX nvoM1VARHPos_XXX nvoM1VARHNeg_XXX nvoM1VARHNet_XXX nvoM1VARHTot_XXX nvoM1VAHTot_XXX nvoM2WHRec_XXX nvoM2WHDel_XXX nvoM2WHNet_XXX nvoM2WHTot_XXX nvoM2VARHPos_XXX nvoM2VARHNeg_XXX nvoM2VARHNet_XXX nvoM2VARHTot_XXX nvoM2VAHTot_XXX nvoM3WHRec_XXX nvoM3WHDel_XXX nvoM3WHNet_XXX nvoM3WHTot_XXX nvoM3VARHPos_XXX nvoM3VARHNeg_XXX nvoM3VARHNet_XXX nvoM3VARHTot_XXX nvoM3VAHTot_XXX nvoM4WHRec_XXX nvoM4WHDel_XXX nvoM4WHNet_XXX nvoM4WHTot_XXX nvoM4VARHPos_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-15 A: Protocol Data Points for EIG Meters PointName MTR04VARͲhoursNegative A.7: MP200-S Metering MTR04VARͲhoursNet MTR04VARͲhoursTotal MTR04VAͲhoursTotal MTR05WͲhoursReceived MTR05WͲhoursDelivered MTR05WͲhoursNet MTR05WͲhoursTotal MTR05VARͲhoursPositive MTR05VARͲhoursNegative MTR05VARͲhoursNet MTR05VARͲhoursTotal MTR05VAͲhoursTotal MTR06WͲhoursReceived MTR06WͲhoursDelivered MTR06WͲhoursNet MTR06WͲhoursTotal MTR06VARͲhoursPositive MTR06VARͲhoursNegative MTR06VARͲhoursNet MTR06VARͲhoursTotal MTR06VAͲhoursTotal MTR07WͲhoursReceived MTR07WͲhoursDelivered MTR07WͲhoursNet MTR07WͲhoursTotal MTR07VARͲhoursPositive MTR07VARͲhoursNegative MTR07VARͲhoursNet MTR07VARͲhoursTotal MTR07VAͲhoursTotal MTR08WͲhoursReceived MTR08WͲhoursDelivered MTR08WͲhoursNet MTR08WͲhoursTotal BACnet Object Type AI System AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 EIPTagName S32_XXX[032] S32_XXX[033] S32_XXX[034] S32_XXX[035] S32_XXX[036] S32_XXX[037] S32_XXX[038] S32_XXX[039] S32_XXX[040] S32_XXX[041] S32_XXX[042] S32_XXX[043] S32_XXX[044] S32_XXX[045] S32_XXX[046] S32_XXX[047] S32_XXX[048] S32_XXX[049] S32_XXX[050] S32_XXX[051] S32_XXX[052] S32_XXX[053] S32_XXX[054] S32_XXX[055] S32_XXX[056] S32_XXX[057] S32_XXX[058] S32_XXX[059] S32_XXX[060] S32_XXX[061] S32_XXX[062] S32_XXX[063] S32_XXX[064] S32_XXX[065] S32_XXX[066] Doc# E204701 DF1 Address F11:032 F11:033 F11:034 F11:035 F11:036 F11:037 F11:038 F11:039 F11:040 F11:041 F11:042 F11:043 F11:044 F11:045 F11:046 F11:047 F11:048 F11:049 F11:050 F11:051 F11:052 F11:053 F11:054 F11:055 F11:056 F11:057 F11:058 F11:059 F11:060 F11:061 F11:062 F11:063 F11:064 F11:065 F11:066 LonName nvoM4VARHNeg_XXX nvoM4VARHNet_XXX nvoM4VARHTot_XXX nvoM4VAHTot_XXX nvoM5WHRec_XXX nvoM5WHDel_XXX nvoM5WHNet_XXX nvoM5WHTot_XXX nvoM5VARHPos_XXX nvoM5VARHNeg_XXX nvoM5VARHNet_XXX nvoM5VARHTot_XXX nvoM5VAHTot_XXX nvoM6WHRec_XXX nvoM6WHDel_XXX nvoM6WHNet_XXX nvoM6WHTot_XXX nvoM6VARHPos_XXX nvoM6VARHNeg_XXX nvoM6VARHNet_XXX nvoM6VARHTot_XXX nvoM6VAHTot_XXX nvoM7WHRec_XXX nvoM7WHDel_XXX nvoM7WHNet_XXX nvoM7WHTot_XXX nvoM7VARHPos_XXX nvoM7VARHNeg_XXX nvoM7VARHNet_XXX nvoM7VARHTot_XXX nvoM7VAHTot_XXX nvoM8WHRec_XXX nvoM8WHDel_XXX nvoM8WHNet_XXX nvoM8WHTot_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-16 A: Protocol Data Points for EIG Meters PointName MTR08VARͲhoursPositive MTR08VARͲhoursNegative MTR08VARͲhoursNet MTR08VARͲhoursTotal MTR08VAͲhoursTotal MTR01PositiveWatts3ͲPhAvg MTR01PositiveVARs3ͲPhAvg MTR01NegativeWatts3ͲPhAvg MTR01NegativeVARs3ͲPhAvg MTR01VAs3ͲPhAvg MTR02PositiveWatts3ͲPhAvg MTR02PositiveVARs3ͲPhAvg MTR02NegativeWatts3ͲPhAvg MTR02NegativeVARs3ͲPhAvg MTR02VAs3ͲPhAvg MTR03PositiveWatts3ͲPhAvg MTR03PositiveVARs3ͲPhAvg MTR03NegativeWatts3ͲPhAvg MTR03NegativeVARs3ͲPhAvg MTR03VAs3ͲPhAvg MTR04PositiveWatts3ͲPhAvg MTR04PositiveVARs3ͲPhAvg MTR04NegativeWatts3ͲPhAvg MTR04NegativeVARs3ͲPhAvg MTR04VAs3ͲPhAvg MTR05PositiveWatts3ͲPhAvg MTR05PositiveVARs3ͲPhAvg MTR05NegativeWatts3ͲPhAvg MTR05NegativeVARs3ͲPhAvg MTR05VAs3ͲPhAvg MTR06PositiveWatts3ͲPhAvg MTR06PositiveVARs3ͲPhAvg MTR06NegativeWatts3ͲPhAvg MTR06NegativeVARs3ͲPhAvg MTR06VAs3ͲPhAvg BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 EIPTagName S32_XXX[067] S32_XXX[068] S32_XXX[069] S32_XXX[070] S32_XXX[071] Flt_XXX[071] Flt_XXX[072] Flt_XXX[073] Flt_XXX[074] Flt_XXX[075] Flt_XXX[076] Flt_XXX[077] Flt_XXX[078] Flt_XXX[079] Flt_XXX[080] Flt_XXX[081] Flt_XXX[082] Flt_XXX[083] Flt_XXX[084] Flt_XXX[085] Flt_XXX[086] Flt_XXX[087] Flt_XXX[088] Flt_XXX[089] Flt_XXX[090] Flt_XXX[091] Flt_XXX[092] Flt_XXX[093] Flt_XXX[094] Flt_XXX[095] Flt_XXX[096] Flt_XXX[097] Flt_XXX[098] Flt_XXX[099] Flt_XXX[100] Doc# E204701 DF1 Address F11:067 F11:068 F11:069 F11:070 F11:071 F10:071 F10:072 F10:073 F10:074 F10:075 F10:076 F10:077 F10:078 F10:079 F10:080 F10:081 F10:082 F10:083 F10:084 F10:085 F10:086 F10:087 F10:088 F10:089 F10:090 F10:091 F10:092 F10:093 F10:094 F10:095 F10:096 F10:097 F10:098 F10:099 F10:100 LonName nvoM8VARHPos_XXX nvoM8VARHNeg_XXX nvoM8VARHNet_XXX nvoM8VARHTot_XXX nvoM8VAHTot_XXX nvoM1PsWtAvg_XXX nvoM1PsVARAv_XXX nvoM1NgWtAvg_XXX nvoM1NgVARAv_XXX nvoM1VAsAvg_XXX nvoM2PsWtAvg_XXX nvoM2PsVARAv_XXX nvoM2NgWtAvg_XXX nvoM2NgVARAv_XXX nvoM2VAsAvg_XXX nvoM3PsWtAvg_XXX nvoM3PsVARAv_XXX nvoM3NgWtAvg_XXX nvoM3NgVARAv_XXX nvoM3VAsAvg_XXX nvoM4PsWtAvg_XXX nvoM4PsVARAv_XXX nvoM4NgWtAvg_XXX nvoM4NgVARAv_XXX nvoM4VAsAvg_XXX nvoM5PsWtAvg_XXX nvoM5PsVARAv_XXX nvoM5NgWtAvg_XXX nvoM5NgVARAv_XXX nvoM5VAsAvg_XXX nvoM6PsWtAvg_XXX nvoM6PsVARAv_XXX nvoM6NgWtAvg_XXX nvoM6NgVARAv_XXX nvoM6VAsAvg_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-17 A: Protocol Data Points for EIG Meters PointName MTR07PositiveWatts3ͲPhAvg MTR07PositiveVARs3ͲPhAvg MTR07NegativeWatts3ͲPhAvg MTR07NegativeVARs3ͲPhAvg MTR07VAs3ͲPhAvg MTR08PositiveWatts3ͲPhAvg MTR08PositiveVARs3ͲPhAvg MTR08NegativeWatts3ͲPhAvg MTR08NegativeVARs3ͲPhAvg MTR08VAs3ͲPhAvg CPUStatus CurrentTimeReg1 CurrentTimeReg2 CurrentTimeReg3 MTR01PositiveWatts3ͲPhMaxAvgDem MTR01PositiveVARs3ͲPhMaxAvgDem MTR01NegativeWatts3ͲPhMaxAvgDem MTR01NegativeVARs3ͲPhMaxAvgDem MTR02PositiveWatts3ͲPhMaxAvgDem MTR02PositiveVARs3ͲPhMaxAvgDem MTR02NegativeWatts3ͲPhMaxAvgDem MTR02NegativeVARs3ͲPhMaxAvgDem MTR03PositiveWatts3ͲPhMaxAvgDem MTR03PositiveVARs3ͲPhMaxAvgDem MTR03NegativeWatts3ͲPhMaxAvgDem MTR03NegativeVARs3ͲPhMaxAvgDem MTR04PositiveWatts3ͲPhMaxAvgDem MTR04PositiveVARs3ͲPhMaxAvgDem MTR04NegativeWatts3ͲPhMaxAvgDem MTR04NegativeVARs3ͲPhMaxAvgDem MTR05PositiveWatts3ͲPhMaxAvgDem MTR05PositiveVARs3ͲPhMaxAvgDem MTR05NegativeWatts3ͲPhMaxAvgDem MTR05NegativeVARs3ͲPhMaxAvgDem MTR06PositiveWatts3ͲPhMaxAvgDem BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 EIPTagName Flt_XXX[101] Flt_XXX[102] Flt_XXX[103] Flt_XXX[104] Flt_XXX[105] Flt_XXX[106] Flt_XXX[107] Flt_XXX[108] Flt_XXX[109] Flt_XXX[110] Dev1_XXX[000] Dev1_XXX[001] Dev1_XXX[002] Dev1_XXX[003] Flt_XXX[111] Flt_XXX[112] Flt_XXX[113] Flt_XXX[114] Flt_XXX[115] Flt_XXX[116] Flt_XXX[117] Flt_XXX[118] Flt_XXX[119] Flt_XXX[120] Flt_XXX[121] Flt_XXX[122] Flt_XXX[123] Flt_XXX[124] Flt_XXX[125] Flt_XXX[126] Flt_XXX[127] Flt_XXX[128] Flt_XXX[129] Flt_XXX[130] Flt_XXX[131] Doc# E204701 DF1 Address F10:101 F10:102 F10:103 F10:104 F10:105 F10:106 F10:107 F10:108 F10:109 F10:110 N12:000 N12:001 N12:002 N12:003 F10:111 F10:112 F10:113 F10:114 F10:115 F10:116 F10:117 F10:118 F10:119 F10:120 F10:121 F10:122 F10:123 F10:124 F10:125 F10:126 F10:127 F10:128 F10:129 F10:130 F10:131 LonName nvoM7PsWtAvg_XXX nvoM7PsVARAv_XXX nvoM7NgWtAvg_XXX nvoM7NgVARAv_XXX nvoM7VAsAvg_XXX nvoM8PsWtAvg_XXX nvoM8PsVARAv_XXX nvoM8NgWtAvg_XXX nvoM8NgVARAv_XXX nvoM8VAsAvg_XXX nvoCPUStatus_XXX nvoCurTime1_XXX nvoCurTime2_XXX nvoCurTime3_XXX nvo1PWtMxAvD_XXX nvo1PVARMxAv_XXX nvo1NWtMxAvD_XXX nvo1NVARMxAv_XXX nvo2PWtMxAvD_XXX nvo2PVARMxAv_XXX nvo2NWtMxAvD_XXX nvo2NVARMxAv_XXX nvo3PWtMxAvD_XXX nvo3PVARMxAv_XXX nvo3NWtMxAvD_XXX nvo3NVARMxAv_XXX nvo4PWtMxAvD_XXX nvo4PVARMxAv_XXX nvo4NWtMxAvD_XXX nvo4NVARMxAv_XXX nvo5PWtMxAvD_XXX nvo5PVARMxAv_XXX nvo5NWtMxAvD_XXX nvo5NVARMxAv_XXX nvo6PWtMxAvD_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-18 A: Protocol Data Points for EIG Meters BACnet Object Type MTR06PositiveVARs3ͲPhMaxAvgDem AI MTR06NegativeWatts3ͲPhMaxAvgDem AI MTR06NegativeVARs3ͲPhMaxAvgDem AI MTR07PositiveWatts3ͲPhMaxAvgDem AI MTR07PositiveVARs3ͲPhMaxAvgDem AI MTR07NegativeWatts3ͲPhMaxAvgDem AI MTR07NegativeVARs3ͲPhMaxAvgDem AI MTR08PositiveWatts3ͲPhMaxAvgDem AI MTR08PositiveVARs3ͲPhMaxAvgDem AI MTR08NegativeWatts3ͲPhMaxAvgDem AI MTR08NegativeVARs3ͲPhMaxAvgDem AI SerialNumberReg1 AI SerialNumberReg2 AI SerialNumberReg3 AI SerialNumberReg4 AI SerialNumberReg5 AI SerialNumberReg6 AI SerialNumberReg7 AI SerialNumberReg8 AI CTdenominator AI MTR01CTNumerator AI MTR02CTNumerator AI MTR03CTNumerator AI MTR04CTNumerator AI MTR05CTNumerator AI MTR06CTNumerator AI MTR07CTNumerator AI MTR08CTNumerator AI PTNumerator AI PTdenominator AI SystemHookup AI PasswordforResetinuse BI PasswordforConfigurationinuse BI PointName BACnet Object ID 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI DI DI Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Point Address 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 EIPTagName Flt_XXX[132] Flt_XXX[133] Flt_XXX[134] Flt_XXX[135] Flt_XXX[136] Flt_XXX[137] Flt_XXX[138] Flt_XXX[139] Flt_XXX[140] Flt_XXX[141] Flt_XXX[142] Dev2_XXX[000] Dev2_XXX[001] Dev2_XXX[002] Dev2_XXX[003] Dev2_XXX[004] Dev2_XXX[005] Dev2_XXX[006] Dev2_XXX[007] Dev2_XXX[008] Dev2_XXX[009] Dev2_XXX[010] Dev2_XXX[011] Dev2_XXX[012] Dev2_XXX[013] Dev2_XXX[014] Dev2_XXX[015] Dev2_XXX[016] Dev2_XXX[017] Dev2_XXX[018] Dev2_XXX[019] Byt_XXX[0] Byt_XXX[1] Doc# E204701 DF1 Address F10:132 F10:133 F10:134 F10:135 F10:136 F10:137 F10:138 F10:139 F10:140 F10:141 F10:142 N13:000 N13:001 N13:002 N13:003 N13:004 N13:005 N13:006 N13:007 N13:008 N13:009 N13:010 N13:011 N13:012 N13:013 N13:014 N13:015 N13:016 N13:017 N13:018 N13:019 N14:0 N14:1 LonName nvo6PVARMxAv_XXX nvo6NWtMxAvD_XXX nvo6NVARMxAv_XXX nvo7PWtMxAvD_XXX nvo7PVARMxAv_XXX nvo7NWtMxAvD_XXX nvo7NVARMxAv_XXX nvo8PWtMxAvD_XXX nvo8PVARMxAv_XXX nvo8NWtMxAvD_XXX nvo8NVARMxAv_XXX nvoSerNum1_XXX nvoSerNum2_XXX nvoSerNum3_XXX nvoSerNum4_XXX nvoSerNum5_XXX nvoSerNum6_XXX nvoSerNum7_XXX nvoSerNum8_XXX nvoCT_den_XXX nvoM1CT_num_XXX nvoM2CT_num_XXX nvoM3CT_num_XXX nvoM4CT_num_XXX nvoM5CT_num_XXX nvoM6CT_num_XXX nvoM7CT_num_XXX nvoM8CT_num_XXX nvoPT_num_XXX nvoPT_den_XXX nvoSysHookup_XXX nvoPswdReset_XXX nvoPswdCnfg_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc A-19 A: Protocol Data Points for EIG Meters A.7: MP200-S Metering System PointName Volts Frequency AmpsMeter01 AmpsMeter02 AmpsMeter03 WattsMeter01 WattsMeter02 WattsMeter03 VARsMeter01 VARsMeter02 VARsMeter03 VAsMeter01 VAsMeter02 VAsMeter03 PowerFactorMeter01 PowerFactorMeter02 PowerFactorMeter03 AmpsMeter04 AmpsMeter05 AmpsMeter06 WattsMeter04 WattsMeter05 WattsMeter06 VARsMeter04 VARsMeter05 VARsMeter06 VAsMeter04 VAsMeter05 VAsMeter06 PowerFactorMeter04 PowerFactorMeter05 PowerFactorMeter06 AmpsMeter07 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 EIPTagName Flt_XXX[000] Flt_XXX[001] Flt_XXX[002] Flt_XXX[003] Flt_XXX[004] Flt_XXX[005] Flt_XXX[006] Flt_XXX[007] Flt_XXX[008] Flt_XXX[009] Flt_XXX[010] Flt_XXX[011] Flt_XXX[012] Flt_XXX[013] Flt_XXX[014] Flt_XXX[015] Flt_XXX[016] Flt_XXX[017] Flt_XXX[018] Flt_XXX[019] Flt_XXX[020] Flt_XXX[021] Flt_XXX[022] Flt_XXX[023] Flt_XXX[024] Flt_XXX[025] Flt_XXX[026] Flt_XXX[027] Flt_XXX[028] Flt_XXX[029] Flt_XXX[030] Flt_XXX[031] Flt_XXX[032] Doc# E204701 DF1 Address F10:000 F10:001 F10:002 F10:003 F10:004 F10:005 F10:006 F10:007 F10:008 F10:009 F10:010 F10:011 F10:012 F10:013 F10:014 F10:015 F10:016 F10:017 F10:018 F10:019 F10:020 F10:021 F10:022 F10:023 F10:024 F10:025 F10:026 F10:027 F10:028 F10:029 F10:030 F10:031 F10:032 LonName nvoVolts_XXX nvoFrequency_XXX nvoAmpsM1_XXX nvoAmpsM2_XXX nvoAmpsM3_XXX nvoWattsM1_XXX nvoWattsM2_XXX nvoWattsM3_XXX nvoVARsM1_XXX nvoVARsM2_XXX nvoVARsM3_XXX nvoVAsM1_XXX nvoVAsM2_XXX nvoVAsM3_XXX nvoPFM1_XXX nvoPFM2_XXX nvoPFM3_XXX nvoAmpsM4_XXX nvoAmpsM5_XXX nvoAmpsM6_XXX nvoWattsM4_XXX nvoWattsM5_XXX nvoWattsM6_XXX nvoVARsM4_XXX nvoVARsM5_XXX nvoVARsM6_XXX nvoVAsM4_XXX nvoVAsM5_XXX nvoVAsM6_XXX nvoPFM4_XXX nvoPFM5_XXX nvoPFM6_XXX nvoAmpsM7_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-20 A: Protocol Data Points for EIG Meters PointName AmpsMeter08 AmpsMeter09 WattsMeter07 WattsMeter08 WattsMeter09 VARsMeter07 VARsMeter08 VARsMeter09 VAsMeter07 VAsMeter08 VAsMeter09 PowerFactorMeter07 PowerFactorMeter08 PowerFactorMeter09 AmpsMeter10 AmpsMeter11 AmpsMeter12 WattsMeter10 WattsMeter11 WattsMeter12 VARsMeter10 VARsMeter11 VARsMeter12 VAsMeter10 VAsMeter11 VAsMeter12 PowerFactorMeter10 PowerFactorMeter11 PowerFactorMeter12 AmpsMeter13 AmpsMeter14 AmpsMeter15 WattsMeter13 WattsMeter14 WattsMeter15 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 EIPTagName Flt_XXX[033] Flt_XXX[034] Flt_XXX[035] Flt_XXX[036] Flt_XXX[037] Flt_XXX[038] Flt_XXX[039] Flt_XXX[040] Flt_XXX[041] Flt_XXX[042] Flt_XXX[043] Flt_XXX[044] Flt_XXX[045] Flt_XXX[046] Flt_XXX[047] Flt_XXX[048] Flt_XXX[049] Flt_XXX[050] Flt_XXX[051] Flt_XXX[052] Flt_XXX[053] Flt_XXX[054] Flt_XXX[055] Flt_XXX[056] Flt_XXX[057] Flt_XXX[058] Flt_XXX[059] Flt_XXX[060] Flt_XXX[061] Flt_XXX[062] Flt_XXX[063] Flt_XXX[064] Flt_XXX[065] Flt_XXX[066] Flt_XXX[067] Doc# E204701 DF1 Address F10:033 F10:034 F10:035 F10:036 F10:037 F10:038 F10:039 F10:040 F10:041 F10:042 F10:043 F10:044 F10:045 F10:046 F10:047 F10:048 F10:049 F10:050 F10:051 F10:052 F10:053 F10:054 F10:055 F10:056 F10:057 F10:058 F10:059 F10:060 F10:061 F10:062 F10:063 F10:064 F10:065 F10:066 F10:067 LonName nvoAmpsM8_XXX nvoAmpsM9_XXX nvoWattsM7_XXX nvoWattsM8_XXX nvoWattsM9_XXX nvoVARsM7_XXX nvoVARsM8_XXX nvoVARsM9_XXX nvoVAsM7_XXX nvoVAsM8_XXX nvoVAsM9_XXX nvoPFM7_XXX nvoPFM8_XXX nvoPFM9_XXX nvoAmpsM10_XXX nvoAmpsM11_XXX nvoAmpsM12_XXX nvoWattsM10_XXX nvoWattsM11_XXX nvoWattsM12_XXX nvoVARsM10_XXX nvoVARsM11_XXX nvoVARsM12_XXX nvoVAsM10_XXX nvoVAsM11_XXX nvoVAsM12_XXX nvoPFM10_XXX nvoPFM11_XXX nvoPFM12_XXX nvoAmpsM13_XXX nvoAmpsM14_XXX nvoAmpsM15_XXX nvoWattsM13_XXX nvoWattsM14_XXX nvoWattsM15_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-21 A: Protocol Data Points for EIG Meters PointName VARsMeter13 VARsMeter14 VARsMeter15 VAsMeter13 VAsMeter14 VAsMeter15 PowerFactorMeter13 PowerFactorMeter14 PowerFactorMeter15 AmpsMeter16 AmpsMeter17 AmpsMeter18 WattsMeter16 WattsMeter17 WattsMeter18 VARsMeter16 VARsMeter17 VARsMeter18 VAsMeter16 VAsMeter17 VAsMeter18 PowerFactorMeter16 PowerFactorMeter17 PowerFactorMeter18 AmpsMeter19 AmpsMeter20 AmpsMeter21 WattsMeter19 WattsMeter20 WattsMeter21 VARsMeter19 VARsMeter20 VARsMeter21 VAsMeter19 VAsMeter20 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 EIPTagName Flt_XXX[068] Flt_XXX[069] Flt_XXX[070] Flt_XXX[071] Flt_XXX[072] Flt_XXX[073] Flt_XXX[074] Flt_XXX[075] Flt_XXX[076] Flt_XXX[077] Flt_XXX[078] Flt_XXX[079] Flt_XXX[080] Flt_XXX[081] Flt_XXX[082] Flt_XXX[083] Flt_XXX[084] Flt_XXX[085] Flt_XXX[086] Flt_XXX[087] Flt_XXX[088] Flt_XXX[089] Flt_XXX[090] Flt_XXX[091] Flt_XXX[092] Flt_XXX[093] Flt_XXX[094] Flt_XXX[095] Flt_XXX[096] Flt_XXX[097] Flt_XXX[098] Flt_XXX[099] Flt_XXX[100] Flt_XXX[101] Flt_XXX[102] Doc# E204701 DF1 Address F10:068 F10:069 F10:070 F10:071 F10:072 F10:073 F10:074 F10:075 F10:076 F10:077 F10:078 F10:079 F10:080 F10:081 F10:082 F10:083 F10:084 F10:085 F10:086 F10:087 F10:088 F10:089 F10:090 F10:091 F10:092 F10:093 F10:094 F10:095 F10:096 F10:097 F10:098 F10:099 F10:100 F10:101 F10:102 LonName nvoVARsM13_XXX nvoVARsM14_XXX nvoVARsM15_XXX nvoVAsM13_XXX nvoVAsM14_XXX nvoVAsM15_XXX nvoPFM13_XXX nvoPFM14_XXX nvoPFM15_XXX nvoAmpsM16_XXX nvoAmpsM17_XXX nvoAmpsM18_XXX nvoWattsM16_XXX nvoWattsM17_XXX nvoWattsM18_XXX nvoVARsM16_XXX nvoVARsM17_XXX nvoVARsM18_XXX nvoVAsM16_XXX nvoVAsM17_XXX nvoVAsM18_XXX nvoPFM16_XXX nvoPFM17_XXX nvoPFM18_XXX nvoAmpsM19_XXX nvoAmpsM20_XXX nvoAmpsM21_XXX nvoWattsM19_XXX nvoWattsM20_XXX nvoWattsM21_XXX nvoVARsM19_XXX nvoVARsM20_XXX nvoVARsM21_XXX nvoVAsM19_XXX nvoVAsM20_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-22 A: Protocol Data Points for EIG Meters PointName VAsMeter21 PowerFactorMeter19 PowerFactorMeter20 PowerFactorMeter21 AmpsMeter22 AmpsMeter23 AmpsMeter24 WattsMeter22 WattsMeter23 WattsMeter24 VARsMeter22 VARsMeter23 VARsMeter24 VAsMeter22 VAsMeter23 VAsMeter24 PowerFactorMeter22 PowerFactorMeter23 PowerFactorMeter24 WͲhoursReceivedMeter01 WͲhoursReceivedMeter02 WͲhoursReceivedMeter03 WͲhoursDeliveredMeter01 WͲhoursDeliveredMeter02 WͲhoursDeliveredMeter03 WͲhoursNetMeter01 WͲhoursNetMeter02 WͲhoursNetMeter03 WͲhoursTotalMeter01 WͲhoursTotalMeter02 WͲhoursTotalMeter03 VARͲhoursPositiveMeter01 VARͲhoursPositiveMeter02 VARͲhoursPositiveMeter03 VARͲhoursNegativeMeter01 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 EIPTagName Flt_XXX[103] Flt_XXX[104] Flt_XXX[105] Flt_XXX[106] Flt_XXX[107] Flt_XXX[108] Flt_XXX[109] Flt_XXX[110] Flt_XXX[111] Flt_XXX[112] Flt_XXX[113] Flt_XXX[114] Flt_XXX[115] Flt_XXX[116] Flt_XXX[117] Flt_XXX[118] Flt_XXX[119] Flt_XXX[120] Flt_XXX[121] S32_XXX[000] S32_XXX[001] S32_XXX[002] S32_XXX[003] S32_XXX[004] S32_XXX[005] S32_XXX[006] S32_XXX[007] S32_XXX[008] S32_XXX[009] S32_XXX[010] S32_XXX[011] S32_XXX[012] S32_XXX[013] S32_XXX[014] S32_XXX[015] Doc# E204701 DF1 Address F10:103 F10:104 F10:105 F10:106 F10:107 F10:108 F10:109 F10:110 F10:111 F10:112 F10:113 F10:114 F10:115 F10:116 F10:117 F10:118 F10:119 F10:120 F10:121 F12:000 F12:001 F12:002 F12:003 F12:004 F12:005 F12:006 F12:007 F12:008 F12:009 F12:010 F12:011 F12:012 F12:013 F12:014 F12:015 LonName nvoVAsM21_XXX nvoPFM19_XXX nvoPFM20_XXX nvoPFM21_XXX nvoAmpsM22_XXX nvoAmpsM23_XXX nvoAmpsM24_XXX nvoWattsM22_XXX nvoWattsM23_XXX nvoWattsM24_XXX nvoVARsM22_XXX nvoVARsM23_XXX nvoVARsM24_XXX nvoVAsM22_XXX nvoVAsM23_XXX nvoVAsM24_XXX nvoPFM22_XXX nvoPFM23_XXX nvoPFM24_XXX nvoWHRecM1_XXX nvoWHRecM2_XXX nvoWHRecM3_XXX nvoWHDelM1_XXX nvoWHDelM2_XXX nvoWHDelM3_XXX nvoWHNetM1_XXX nvoWHNetM2_XXX nvoWHNetM3_XXX nvoWHTotM1_XXX nvoWHTotM2_XXX nvoWHTotM3_XXX nvoVARhPosM1_XXX nvoVARhPosM2_XXX nvoVARhPosM3_XXX nvoVARhNegM1_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-23 A: Protocol Data Points for EIG Meters PointName VARͲhoursNegativeMeter02 VARͲhoursNegativeMeter03 VARͲhoursNetMeter01 VARͲhoursNetMeter02 VARͲhoursNetMeter03 VARͲhoursTotalMeter01 VARͲhoursTotalMeter02 VARͲhoursTotalMeter03 VAͲhoursTotalMeter01 VAͲhoursTotalMeter02 VAͲhoursTotalMeter03 WͲhoursReceivedMeter04 WͲhoursReceivedMeter05 WͲhoursReceivedMeter06 WͲhoursDeliveredMeter04 WͲhoursDeliveredMeter05 WͲhoursDeliveredMeter06 WͲhoursNetMeter04 WͲhoursNetMeter05 WͲhoursNetMeter06 WͲhoursTotalMeter04 WͲhoursTotalMeter05 WͲhoursTotalMeter06 VARͲhoursPositiveMeter04 VARͲhoursPositiveMeter05 VARͲhoursPositiveMeter06 VARͲhoursNegativeMeter04 VARͲhoursNegativeMeter05 VARͲhoursNegativeMeter06 VARͲhoursNetMeter04 VARͲhoursNetMeter05 VARͲhoursNetMeter06 VARͲhoursTotalMeter04 VARͲhoursTotalMeter05 VARͲhoursTotalMeter06 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 EIPTagName S32_XXX[016] S32_XXX[017] S32_XXX[018] S32_XXX[019] S32_XXX[020] S32_XXX[021] S32_XXX[022] S32_XXX[023] S32_XXX[024] S32_XXX[025] S32_XXX[026] S32_XXX[027] S32_XXX[028] S32_XXX[029] S32_XXX[030] S32_XXX[031] S32_XXX[032] S32_XXX[033] S32_XXX[034] S32_XXX[035] S32_XXX[036] S32_XXX[037] S32_XXX[038] S32_XXX[039] S32_XXX[040] S32_XXX[041] S32_XXX[042] S32_XXX[043] S32_XXX[044] S32_XXX[045] S32_XXX[046] S32_XXX[047] S32_XXX[048] S32_XXX[049] S32_XXX[050] Doc# E204701 DF1 Address F12:016 F12:017 F12:018 F12:019 F12:020 F12:021 F12:022 F12:023 F12:024 F12:025 F12:026 F12:027 F12:028 F12:029 F12:030 F12:031 F12:032 F12:033 F12:034 F12:035 F12:036 F12:037 F12:038 F12:039 F12:040 F12:041 F12:042 F12:043 F12:044 F12:045 F12:046 F12:047 F12:048 F12:049 F12:050 LonName nvoVARhNegM2_XXX nvoVARhNegM3_XXX nvoVARhNetM1_XXX nvoVARhNetM2_XXX nvoVARhNetM3_XXX nvoVARhTotM1_XXX nvoVARhTotM2_XXX nvoVARhTotM3_XXX nvoVAhTotM1_XXX nvoVAhTotM2_XXX nvoVAhTotM3_XXX nvoWHRecM4_XXX nvoWHRecM5_XXX nvoWHRecM6_XXX nvoWHDelM4_XXX nvoWHDelM5_XXX nvoWHDelM6_XXX nvoWHNetM4_XXX nvoWHNetM5_XXX nvoWHNetM6_XXX nvoWHTotM4_XXX nvoWHTotM5_XXX nvoWHTotM6_XXX nvoVARhPosM4_XXX nvoVARhPosM5_XXX nvoVARhPosM6_XXX nvoVARhNegM4_XXX nvoVARhNegM5_XXX nvoVARhNegM6_XXX nvoVARhNetM4_XXX nvoVARhNetM5_XXX nvoVARhNetM6_XXX nvoVARhTotM4_XXX nvoVARhTotM5_XXX nvoVARhTotM6_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-24 A: Protocol Data Points for EIG Meters PointName VAͲhoursTotalMeter04 VAͲhoursTotalMeter05 VAͲhoursTotalMeter06 WͲhoursReceivedMeter07 WͲhoursReceivedMeter08 WͲhoursReceivedMeter09 WͲhoursDeliveredMeter07 WͲhoursDeliveredMeter08 WͲhoursDeliveredMeter09 WͲhoursNetMeter07 WͲhoursNetMeter08 WͲhoursNetMeter09 WͲhoursTotalMeter07 WͲhoursTotalMeter08 WͲhoursTotalMeter09 VARͲhoursPositiveMeter07 VARͲhoursPositiveMeter08 VARͲhoursPositiveMeter09 VARͲhoursNegativeMeter07 VARͲhoursNegativeMeter08 VARͲhoursNegativeMeter09 VARͲhoursNetMeter07 VARͲhoursNetMeter08 VARͲhoursNetMeter09 VARͲhoursTotalMeter07 VARͲhoursTotalMeter08 VARͲhoursTotalMeter09 VAͲhoursTotalMeter07 VAͲhoursTotalMeter08 VAͲhoursTotalMeter09 WͲhoursReceivedMeter10 WͲhoursReceivedMeter11 WͲhoursReceivedMeter12 WͲhoursDeliveredMeter10 WͲhoursDeliveredMeter11 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 EIPTagName S32_XXX[051] S32_XXX[052] S32_XXX[053] S32_XXX[054] S32_XXX[055] S32_XXX[056] S32_XXX[057] S32_XXX[058] S32_XXX[059] S32_XXX[060] S32_XXX[061] S32_XXX[062] S32_XXX[063] S32_XXX[064] S32_XXX[065] S32_XXX[066] S32_XXX[067] S32_XXX[068] S32_XXX[069] S32_XXX[070] S32_XXX[071] S32_XXX[072] S32_XXX[073] S32_XXX[074] S32_XXX[075] S32_XXX[076] S32_XXX[077] S32_XXX[078] S32_XXX[079] S32_XXX[080] S32_XXX[081] S32_XXX[082] S32_XXX[083] S32_XXX[084] S32_XXX[085] Doc# E204701 DF1 Address F12:051 F12:052 F12:053 F12:054 F12:055 F12:056 F12:057 F12:058 F12:059 F12:060 F12:061 F12:062 F12:063 F12:064 F12:065 F12:066 F12:067 F12:068 F12:069 F12:070 F12:071 F12:072 F12:073 F12:074 F12:075 F12:076 F12:077 F12:078 F12:079 F12:080 F12:081 F12:082 F12:083 F12:084 F12:085 LonName nvoVAhTotM4_XXX nvoVAhTotM5_XXX nvoVAhTotM6_XXX nvoWHRecM7_XXX nvoWHRecM8_XXX nvoWHRecM9_XXX nvoWHDelM7_XXX nvoWHDelM8_XXX nvoWHDelM9_XXX nvoWHNetM7_XXX nvoWHNetM8_XXX nvoWHNetM9_XXX nvoWHTotM7_XXX nvoWHTotM8_XXX nvoWHTotM9_XXX nvoVARhPosM7_XXX nvoVARhPosM8_XXX nvoVARhPosM9_XXX nvoVARhNegM7_XXX nvoVARhNegM8_XXX nvoVARhNegM9_XXX nvoVARhNetM7_XXX nvoVARhNetM8_XXX nvoVARhNetM9_XXX nvoVARhTotM7_XXX nvoVARhTotM8_XXX nvoVARhTotM9_XXX nvoVAhTotM7_XXX nvoVAhTotM8_XXX nvoVAhTotM9_XXX nvoWHRecM10_XXX nvoWHRecM11_XXX nvoWHRecM12_XXX nvoWHDelM10_XXX nvoWHDelM11_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-25 A: Protocol Data Points for EIG Meters PointName WͲhoursDeliveredMeter12 WͲhoursNetMeter10 WͲhoursNetMeter11 WͲhoursNetMeter12 WͲhoursTotalMeter10 WͲhoursTotalMeter11 WͲhoursTotalMeter12 VARͲhoursPositiveMeter10 VARͲhoursPositiveMeter11 VARͲhoursPositiveMeter12 VARͲhoursNegativeMeter10 VARͲhoursNegativeMeter11 VARͲhoursNegativeMeter12 VARͲhoursNetMeter10 VARͲhoursNetMeter11 VARͲhoursNetMeter12 VARͲhoursTotalMeter10 VARͲhoursTotalMeter11 VARͲhoursTotalMeter12 VAͲhoursTotalMeter10 VAͲhoursTotalMeter11 VAͲhoursTotalMeter12 WͲhoursReceivedMeter13 WͲhoursReceivedMeter14 WͲhoursReceivedMeter15 WͲhoursDeliveredMeter13 WͲhoursDeliveredMeter14 WͲhoursDeliveredMeter15 WͲhoursNetMeter13 WͲhoursNetMeter14 WͲhoursNetMeter15 WͲhoursTotalMeter13 WͲhoursTotalMeter14 WͲhoursTotalMeter15 VARͲhoursPositiveMeter13 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI N2 Point Address 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 Doc# E204701 EIPTagName S32_XXX[086] S32_XXX[087] S32_XXX[088] S32_XXX[089] S32_XXX[090] S32_XXX[091] S32_XXX[092] S32_XXX[093] S32_XXX[094] S32_XXX[095] S32_XXX[096] S32_XXX[097] S32_XXX[098] S32_XXX[099] S32_XXX[100] S32_XXX[101] S32_XXX[102] S32_XXX[103] S32_XXX[104] S32_XXX[105] S32_XXX[106] S32_XXX[107] S32_XXX[108] S32_XXX[109] S32_XXX[110] S32_XXX[111] S32_XXX[112] S32_XXX[113] S32_XXX[114] S32_XXX[115] S32_XXX[116] S32_XXX[117] S32_XXX[118] S32_XXX[119] S32_XXX[120] DF1 Address F12:086 F12:087 F12:088 F12:089 F12:090 F12:091 F12:092 F12:093 F12:094 F12:095 F12:096 F12:097 F12:098 F12:099 F12:100 F12:101 F12:102 F12:103 F12:104 F12:105 F12:106 F12:107 F12:108 F12:109 F12:110 F12:111 F12:112 F12:113 F12:114 F12:115 F12:116 F12:117 F12:118 F12:119 F12:120 LonName nvoWHDelM12_XXX nvoWHNetM10_XXX nvoWHNetM11_XXX nvoWHNetM12_XXX nvoWHTotM10_XXX nvoWHTotM11_XXX nvoWHTotM12_XXX nvoVARhPsM10_XXX nvoVARhPsM11_XXX nvoVARhPsM12_XXX nvoVARhNgM10_XXX nvoVARhNgM11_XXX nvoVARhNgM12_XXX nvoVARhNtM10_XXX nvoVARhNtM11_XXX nvoVARhNtM12_XXX nvoVARhToM10_XXX nvoVARhToM11_XXX nvoVARhToM12_XXX nvoVAhTotM10_XXX nvoVAhTotM11_XXX nvoVAhTotM12_XXX nvoWHRecM13_XXX nvoWHRecM14_XXX nvoWHRecM15_XXX nvoWHDelM13_XXX nvoWHDelM14_XXX nvoWHDelM15_XXX nvoWHNetM13_XXX nvoWHNetM14_XXX nvoWHNetM15_XXX nvoWHTotM13_XXX nvoWHTotM14_XXX nvoWHTotM15_XXX nvoVARhPsM13_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-26 A: Protocol Data Points for EIG Meters PointName VARͲhoursPositiveMeter14 VARͲhoursPositiveMeter15 VARͲhoursNegativeMeter13 VARͲhoursNegativeMeter14 VARͲhoursNegativeMeter15 VARͲhoursNetMeter13 VARͲhoursNetMeter14 VARͲhoursNetMeter15 VARͲhoursTotalMeter13 VARͲhoursTotalMeter14 VARͲhoursTotalMeter15 VAͲhoursTotalMeter13 VAͲhoursTotalMeter14 VAͲhoursTotalMeter15 WͲhoursReceivedMeter16 WͲhoursReceivedMeter17 WͲhoursReceivedMeter18 WͲhoursDeliveredMeter16 WͲhoursDeliveredMeter17 WͲhoursDeliveredMeter18 WͲhoursNetMeter16 WͲhoursNetMeter17 WͲhoursNetMeter18 WͲhoursTotalMeter16 WͲhoursTotalMeter17 WͲhoursTotalMeter18 VARͲhoursPositiveMeter16 VARͲhoursPositiveMeter17 VARͲhoursPositiveMeter18 VARͲhoursNegativeMeter16 VARͲhoursNegativeMeter17 VARͲhoursNegativeMeter18 VARͲhoursNetMeter16 VARͲhoursNetMeter17 VARͲhoursNetMeter18 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type AI AI AI AI AI AI AI AI AI AI AI AI AI ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF N2 Point Address 244 245 246 247 248 249 250 251 252 253 254 255 256 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 EIPTagName S32_XXX[121] S32_XXX[122] S32_XXX[123] S32_XXX[124] S32_XXX[125] S32_XXX[126] S32_XXX[127] S32_XXX[128] S32_XXX[129] S32_XXX[130] S32_XXX[131] S32_XXX[132] S32_XXX[133] S32_XXX[134] S32_XXX[135] S32_XXX[136] S32_XXX[137] S32_XXX[138] S32_XXX[139] S32_XXX[140] S32_XXX[141] S32_XXX[142] S32_XXX[143] S32_XXX[144] S32_XXX[145] S32_XXX[146] S32_XXX[147] S32_XXX[148] S32_XXX[149] S32_XXX[150] S32_XXX[151] S32_XXX[152] S32_XXX[153] S32_XXX[154] S32_XXX[155] Doc# E204701 DF1 Address F12:121 F12:122 F12:123 F12:124 F12:125 F12:126 F12:127 F12:128 F12:129 F12:130 F12:131 F12:132 F12:133 F12:134 F12:135 F12:136 F12:137 F12:138 F12:139 F12:140 F12:141 F12:142 F12:143 F12:144 F12:145 F12:146 F12:147 F12:148 F12:149 F12:150 F12:151 F12:152 F12:153 F12:154 F12:155 LonName nvoVARhPsM14_XXX nvoVARhPsM15_XXX nvoVARhNgM13_XXX nvoVARhNgM14_XXX nvoVARhNgM15_XXX nvoVARhNtM13_XXX nvoVARhNtM14_XXX nvoVARhNtM15_XXX nvoVARhToM13_XXX nvoVARhToM14_XXX nvoVARhToM15_XXX nvoVAhTotM13_XXX nvoVAhTotM14_XXX nvoVAhTotM15_XXX nvoWHRecM16_XXX nvoWHRecM17_XXX nvoWHRecM18_XXX nvoWHDelM16_XXX nvoWHDelM17_XXX nvoWHDelM18_XXX nvoWHNetM16_XXX nvoWHNetM17_XXX nvoWHNetM18_XXX nvoWHTotM16_XXX nvoWHTotM17_XXX nvoWHTotM18_XXX nvoVARhPsM16_XXX nvoVARhPsM17_XXX nvoVARhPsM18_XXX nvoVARhNgM16_XXX nvoVARhNgM17_XXX nvoVARhNgM18_XXX nvoVARhNtM16_XXX nvoVARhNtM17_XXX nvoVARhNtM18_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-27 A: Protocol Data Points for EIG Meters PointName VARͲhoursTotalMeter16 VARͲhoursTotalMeter17 VARͲhoursTotalMeter18 VAͲhoursTotalMeter16 VAͲhoursTotalMeter17 VAͲhoursTotalMeter18 WͲhoursReceivedMeter19 WͲhoursReceivedMeter20 WͲhoursReceivedMeter21 WͲhoursDeliveredMeter19 WͲhoursDeliveredMeter20 WͲhoursDeliveredMeter21 WͲhoursNetMeter19 WͲhoursNetMeter20 WͲhoursNetMeter21 WͲhoursTotalMeter19 WͲhoursTotalMeter20 WͲhoursTotalMeter21 VARͲhoursPositiveMeter19 VARͲhoursPositiveMeter20 VARͲhoursPositiveMeter21 VARͲhoursNegativeMeter19 VARͲhoursNegativeMeter20 VARͲhoursNegativeMeter21 VARͲhoursNetMeter19 VARͲhoursNetMeter20 VARͲhoursNetMeter21 VARͲhoursTotalMeter19 VARͲhoursTotalMeter20 VARͲhoursTotalMeter21 VAͲhoursTotalMeter19 VAͲhoursTotalMeter20 VAͲhoursTotalMeter21 WͲhoursReceivedMeter22 WͲhoursReceivedMeter23 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF N2 Point Address 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 EIPTagName S32_XXX[156] S32_XXX[157] S32_XXX[158] S32_XXX[159] S32_XXX[160] S32_XXX[161] S32_XXX[162] S32_XXX[163] S32_XXX[164] S32_XXX[165] S32_XXX[166] S32_XXX[167] S32_XXX[168] S32_XXX[169] S32_XXX[170] S32_XXX[171] S32_XXX[172] S32_XXX[173] S32_XXX[174] S32_XXX[175] S32_XXX[176] S32_XXX[177] S32_XXX[178] S32_XXX[179] S32_XXX[180] S32_XXX[181] S32_XXX[182] S32_XXX[183] S32_XXX[184] S32_XXX[185] S32_XXX[186] S32_XXX[187] S32_XXX[188] S32_XXX[189] S32_XXX[190] Doc# E204701 DF1 Address F12:156 F12:157 F12:158 F12:159 F12:160 F12:161 F12:162 F12:163 F12:164 F12:165 F12:166 F12:167 F12:168 F12:169 F12:170 F12:171 F12:172 F12:173 F12:174 F12:175 F12:176 F12:177 F12:178 F12:179 F12:180 F12:181 F12:182 F12:183 F12:184 F12:185 F12:186 F12:187 F12:188 F12:189 F12:190 LonName nvoVARhToM16_XXX nvoVARhToM17_XXX nvoVARhToM18_XXX nvoVAhTotM16_XXX nvoVAhTotM17_XXX nvoVAhTotM18_XXX nvoWHRecM19_XXX nvoWHRecM20_XXX nvoWHRecM21_XXX nvoWHDelM19_XXX nvoWHDelM20_XXX nvoWHDelM21_XXX nvoWHNetM19_XXX nvoWHNetM20_XXX nvoWHNetM21_XXX nvoWHTotM19_XXX nvoWHTotM20_XXX nvoWHTotM21_XXX nvoVARhPsM19_XXX nvoVARhPsM20_XXX nvoVARhPsM21_XXX nvoVARhNgM19_XXX nvoVARhNgM20_XXX nvoVARhNgM21_XXX nvoVARhNtM19_XXX nvoVARhNtM20_XXX nvoVARhNtM21_XXX nvoVARhToM19_XXX nvoVARhToM20_XXX nvoVARhToM21_XXX nvoVAhTotM19_XXX nvoVAhTotM20_XXX nvoVAhTotM21_XXX nvoWHRecM22_XXX nvoWHRecM23_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-28 A: Protocol Data Points for EIG Meters PointName WͲhoursReceivedMeter24 WͲhoursDeliveredMeter22 WͲhoursDeliveredMeter23 WͲhoursDeliveredMeter24 WͲhoursNetMeter22 WͲhoursNetMeter23 WͲhoursNetMeter24 WͲhoursTotalMeter22 WͲhoursTotalMeter23 WͲhoursTotalMeter24 VARͲhoursPositiveMeter22 VARͲhoursPositiveMeter23 VARͲhoursPositiveMeter24 VARͲhoursNegativeMeter22 VARͲhoursNegativeMeter23 VARͲhoursNegativeMeter24 VARͲhoursNetMeter22 VARͲhoursNetMeter23 VARͲhoursNetMeter24 VARͲhoursTotalMeter22 VARͲhoursTotalMeter23 VARͲhoursTotalMeter24 VAͲhoursTotalMeter22 VAͲhoursTotalMeter23 VAͲhoursTotalMeter24 PositiveWattsMeter01Avg PositiveWattsMeter02Avg PositiveWattsMeter03Avg PositiveVARsMeter01Avg PositiveVARsMeter02Avg PositiveVARsMeter03Avg NegativeWattsMeter01Avg NegativeWattsMeter02Avg NegativeWattsMeter03Avg NegativeVARsMeter01Avg BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF N2 Point Address 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 EIPTagName S32_XXX[191] S32_XXX[192] S32_XXX[193] S32_XXX[194] S32_XXX[195] S32_XXX[196] S32_XXX[197] S32_XXX[198] S32_XXX[199] S32_XXX[200] S32_XXX[201] S32_XXX[202] S32_XXX[203] S32_XXX[204] S32_XXX[205] S32_XXX[206] S32_XXX[207] S32_XXX[208] S32_XXX[209] S32_XXX[210] S32_XXX[211] S32_XXX[212] S32_XXX[213] S32_XXX[214] S32_XXX[215] Flt_XXX[122] Flt_XXX[123] Flt_XXX[124] Flt_XXX[125] Flt_XXX[126] Flt_XXX[127] Flt_XXX[128] Flt_XXX[129] Flt_XXX[130] Flt_XXX[131] Doc# E204701 DF1 Address F12:191 F12:192 F12:193 F12:194 F12:195 F12:196 F12:197 F12:198 F12:199 F12:200 F12:201 F12:202 F12:203 F12:204 F12:205 F12:206 F12:207 F12:208 F12:209 F12:210 F12:211 F12:212 F12:213 F12:214 F12:215 F10:122 F10:123 F10:124 F10:125 F10:126 F10:127 F10:128 F10:129 F10:130 F10:131 LonName nvoWHRecM24_XXX nvoWHDelM22_XXX nvoWHDelM23_XXX nvoWHDelM24_XXX nvoWHNetM22_XXX nvoWHNetM23_XXX nvoWHNetM24_XXX nvoWHTotM22_XXX nvoWHTotM23_XXX nvoWHTotM24_XXX nvoVARhPsM22_XXX nvoVARhPsM23_XXX nvoVARhPsM24_XXX nvoVARhNgM22_XXX nvoVARhNgM23_XXX nvoVARhNgM24_XXX nvoVARhNtM22_XXX nvoVARhNtM23_XXX nvoVARhNtM24_XXX nvoVARhToM22_XXX nvoVARhToM23_XXX nvoVARhToM24_XXX nvoVAhTotM22_XXX nvoVAhTotM23_XXX nvoVAhTotM24_XXX nvoPsWtM1Avg_XXX nvoPsWtM2Avg_XXX nvoPsWtM3Avg_XXX nvoPsVARM1Av_XXX nvoPsVARM2Av_XXX nvoPsVARM3Av_XXX nvoNgWtM1Avg_XXX nvoNgWtM2Avg_XXX nvoNgWtM3Avg_XXX nvoNgVARM1Av_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-29 A: Protocol Data Points for EIG Meters PointName NegativeVARsMeter02Avg NegativeVARsMeter03Avg PositiveWattsMeter04Avg PositiveWattsMeter05Avg PositiveWattsMeter06Avg PositiveVARsMeter04Avg PositiveVARsMeter05Avg PositiveVARsMeter06Avg NegativeWattsMeter04Avg NegativeWattsMeter05Avg NegativeWattsMeter06Avg NegativeVARsMeter04Avg NegativeVARsMeter05Avg NegativeVARsMeter06Avg PositiveWattsMeter07Avg PositiveWattsMeter08Avg PositiveWattsMeter09Avg PositiveVARsMeter07Avg PositiveVARsMeter08Avg PositiveVARsMeter09Avg NegativeWattsMeter07Avg NegativeWattsMeter08Avg NegativeWattsMeter09Avg NegativeVARsMeter07Avg NegativeVARsMeter08Avg NegativeVARsMeter09Avg PositiveWattsMeter10Avg PositiveWattsMeter11Avg PositiveWattsMeter12Avg PositiveVARsMeter10Avg PositiveVARsMeter11Avg PositiveVARsMeter12Avg NegativeWattsMeter10Avg NegativeWattsMeter11Avg NegativeWattsMeter12Avg BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF N2 Point Address 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 EIPTagName Flt_XXX[132] Flt_XXX[133] Flt_XXX[134] Flt_XXX[135] Flt_XXX[136] Flt_XXX[137] Flt_XXX[138] Flt_XXX[139] Flt_XXX[140] Flt_XXX[141] Flt_XXX[142] Flt_XXX[143] Flt_XXX[144] Flt_XXX[145] Flt_XXX[146] Flt_XXX[147] Flt_XXX[148] Flt_XXX[149] Flt_XXX[150] Flt_XXX[151] Flt_XXX[152] Flt_XXX[153] Flt_XXX[154] Flt_XXX[155] Flt_XXX[156] Flt_XXX[157] Flt_XXX[158] Flt_XXX[159] Flt_XXX[160] Flt_XXX[161] Flt_XXX[162] Flt_XXX[163] Flt_XXX[164] Flt_XXX[165] Flt_XXX[166] Doc# E204701 DF1 Address F10:132 F10:133 F10:134 F10:135 F10:136 F10:137 F10:138 F10:139 F10:140 F10:141 F10:142 F10:143 F10:144 F10:145 F10:146 F10:147 F10:148 F10:149 F10:150 F10:151 F10:152 F10:153 F10:154 F10:155 F10:156 F10:157 F10:158 F10:159 F10:160 F10:161 F10:162 F10:163 F10:164 F10:165 F10:166 LonName nvoNgVARM2Av_XXX nvoNgVARM3Av_XXX nvoPsWtM4Avg_XXX nvoPsWtM5Avg_XXX nvoPsWtM6Avg_XXX nvoPsVARM4Av_XXX nvoPsVARM5Av_XXX nvoPsVARM6Av_XXX nvoNgWtM4Avg_XXX nvoNgWtM5Avg_XXX nvoNgWtM6Avg_XXX nvoNgVARM4Av_XXX nvoNgVARM5Av_XXX nvoNgVARM6Av_XXX nvoPsWtM7Avg_XXX nvoPsWtM8Avg_XXX nvoPsWtM9Avg_XXX nvoPsVARM7Av_XXX nvoPsVARM8Av_XXX nvoPsVARM9Av_XXX nvoNgWtM7Avg_XXX nvoNgWtM8Avg_XXX nvoNgWtM9Avg_XXX nvoNgVARM7Av_XXX nvoNgVARM8Av_XXX nvoNgVARM9Av_XXX nvoPsWtM10Av_XXX nvoPsWtM11Av_XXX nvoPsWtM12Av_XXX nvoPsVAR10Av_XXX nvoPsVAR11Av_XXX nvoPsVAR12Av_XXX nvoNgWtM10Av_XXX nvoNgWtM11Av_XXX nvoNgWtM12Av_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-30 A: Protocol Data Points for EIG Meters PointName NegativeVARsMeter10Avg NegativeVARsMeter11Avg NegativeVARsMeter12Avg PositiveWattsMeter13Avg PositiveWattsMeter14Avg PositiveWattsMeter15Avg PositiveVARsMeter13Avg PositiveVARsMeter14Avg PositiveVARsMeter15Avg NegativeWattsMeter13Avg NegativeWattsMeter14Avg NegativeWattsMeter15Avg NegativeVARsMeter13Avg NegativeVARsMeter14Avg NegativeVARsMeter15Avg PositiveWattsMeter16Avg PositiveWattsMeter17Avg PositiveWattsMeter18Avg PositiveVARsMeter16Avg PositiveVARsMeter17Avg PositiveVARsMeter18Avg NegativeWattsMeter16Avg NegativeWattsMeter17Avg NegativeWattsMeter18Avg NegativeVARsMeter16Avg NegativeVARsMeter17Avg NegativeVARsMeter18Avg PositiveWattsMeter19Avg PositiveWattsMeter20Avg PositiveWattsMeter21Avg PositiveVARsMeter19Avg PositiveVARsMeter20Avg PositiveVARsMeter21Avg NegativeWattsMeter19Avg NegativeWattsMeter20Avg BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF N2 Point Address 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 EIPTagName Flt_XXX[167] Flt_XXX[168] Flt_XXX[169] Flt_XXX[170] Flt_XXX[171] Flt_XXX[172] Flt_XXX[173] Flt_XXX[174] Flt_XXX[175] Flt_XXX[176] Flt_XXX[177] Flt_XXX[178] Flt_XXX[179] Flt_XXX[180] Flt_XXX[181] Flt_XXX[182] Flt_XXX[183] Flt_XXX[184] Flt_XXX[185] Flt_XXX[186] Flt_XXX[187] Flt_XXX[188] Flt_XXX[189] Flt_XXX[190] Flt_XXX[191] Flt_XXX[192] Flt_XXX[193] Flt_XXX[194] Flt_XXX[195] Flt_XXX[196] Flt_XXX[197] Flt_XXX[198] Flt_XXX[199] Flt_XXX[200] Flt_XXX[201] Doc# E204701 DF1 Address F10:167 F10:168 F10:169 F10:170 F10:171 F10:172 F10:173 F10:174 F10:175 F10:176 F10:177 F10:178 F10:179 F10:180 F10:181 F10:182 F10:183 F10:184 F10:185 F10:186 F10:187 F10:188 F10:189 F10:190 F10:191 F10:192 F10:193 F10:194 F10:195 F10:196 F10:197 F10:198 F10:199 F10:200 F10:201 LonName nvoNgVAR10Av_XXX nvoNgVAR11Av_XXX nvoNgVAR12Av_XXX nvoPsWtM13Av_XXX nvoPsWtM14Av_XXX nvoPsWtM15Av_XXX nvoPsVAR13Av_XXX nvoPsVAR14Av_XXX nvoPsVAR15Av_XXX nvoNgWtM13Av_XXX nvoNgWtM14Av_XXX nvoNgWtM15Av_XXX nvoNgVAR13Av_XXX nvoNgVAR14Av_XXX nvoNgVAR15Av_XXX nvoPsWtM16Av_XXX nvoPsWtM17Av_XXX nvoPsWtM18Av_XXX nvoPsVAR16Av_XXX nvoPsVAR17Av_XXX nvoPsVAR18Av_XXX nvoNgWtM16Av_XXX nvoNgWtM17Av_XXX nvoNgWtM18Av_XXX nvoNgVAR16Av_XXX nvoNgVAR17Av_XXX nvoNgVAR18Av_XXX nvoPsWtM19Av_XXX nvoPsWtM20Av_XXX nvoPsWtM21Av_XXX nvoPsVAR19Av_XXX nvoPsVAR20Av_XXX nvoPsVAR21Av_XXX nvoNgWtM19Av_XXX nvoNgWtM20Av_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-31 A: Protocol Data Points for EIG Meters PointName NegativeWattsMeter21Avg NegativeVARsMeter19Avg NegativeVARsMeter20Avg NegativeVARsMeter21Avg PositiveWattsMeter22Avg PositiveWattsMeter23Avg PositiveWattsMeter24Avg PositiveVARsMeter22Avg PositiveVARsMeter23Avg PositiveVARsMeter24Avg NegativeWattsMeter22Avg NegativeWattsMeter23Avg NegativeWattsMeter24Avg NegativeVARsMeter22Avg NegativeVARsMeter23Avg NegativeVARsMeter24Avg CurrentDateandTime1 CurrentDateandTime2 CurrentDateandTime3 PosWattsMeter01MaxAvgDem PosWattsMeter02MaxAvgDem PosWattsMeter03MaxAvgDem PosVARsMeter01MaxAvgDem PosVARsMeter02MaxAvgDem PosVARsMeter03MaxAvgDem NegWattsMeter01MaxAvgDem NegWattsMeter02MaxAvgDem NegWattsMeter03MaxAvgDem NegVARsMeter01MaxAvgDem NegVARsMeter02MaxAvgDem NegVARsMeter03MaxAvgDem PosWattsMeter04MaxAvgDem PosWattsMeter05MaxAvgDem PosWattsMeter06MaxAvgDem PosVARsMeter04MaxAvgDem BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF N2 Point Address 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 EIPTagName Flt_XXX[202] Flt_XXX[203] Flt_XXX[204] Flt_XXX[205] Flt_XXX[206] Flt_XXX[207] Flt_XXX[208] Flt_XXX[209] Flt_XXX[210] Flt_XXX[211] Flt_XXX[212] Flt_XXX[213] Flt_XXX[214] Flt_XXX[215] Flt_XXX[216] Flt_XXX[217] Dev1_XXX[000] Dev1_XXX[001] Dev1_XXX[002] Flt_XXX[218] Flt_XXX[219] Flt_XXX[220] Flt_XXX[221] Flt_XXX[222] Flt_XXX[223] Flt_XXX[224] Flt_XXX[225] Flt_XXX[226] Flt_XXX[227] Flt_XXX[228] Flt_XXX[229] Flt_XXX[230] Flt_XXX[231] Flt_XXX[232] Flt_XXX[233] Doc# E204701 DF1 Address F10:202 F10:203 F10:204 F10:205 F10:206 F10:207 F10:208 F10:209 F10:210 F10:211 F10:212 F10:213 F10:214 F10:215 F10:216 F10:217 N13:000 N13:001 N13:002 F10:218 F10:219 F10:220 F10:221 F10:222 F10:223 F10:224 F10:225 F10:226 F10:227 F10:228 F10:229 F10:230 F10:231 F10:232 F10:233 LonName nvoNgWtM21Av_XXX nvoNgVAR19Av_XXX nvoNgVAR20Av_XXX nvoNgVAR21Av_XXX nvoPsWtM22Av_XXX nvoPsWtM23Av_XXX nvoPsWtM24Av_XXX nvoPsVAR22Av_XXX nvoPsVAR23Av_XXX nvoPsVAR24Av_XXX nvoNgWtM22Av_XXX nvoNgWtM23Av_XXX nvoNgWtM24Av_XXX nvoNgVAR22Av_XXX nvoNgVAR23Av_XXX nvoNgVAR24Av_XXX nvoCurDatTm1_XXX nvoCurDatTm2_XXX nvoCurDatTm3_XXX nvoPWt1MxAvD_XXX nvoPWt2MxAvD_XXX nvoPWt3MxAvD_XXX nvoPVAR1MxAv_XXX nvoPVAR2MxAv_XXX nvoPVAR3MxAv_XXX nvoNWt1MxAvD_XXX nvoNWt2MxAvD_XXX nvoNWt3MxAvD_XXX nvoNVAR1MxAv_XXX nvoNVAR2MxAv_XXX nvoNVAR3MxAv_XXX nvoPWt4MxAvD_XXX nvoPWt5MxAvD_XXX nvoPWt6MxAvD_XXX nvoPVAR4MxAv_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-32 A: Protocol Data Points for EIG Meters PointName PosVARsMeter05MaxAvgDem PosVARsMeter06MaxAvgDem NegWattsMeter04MaxAvgDem NegWattsMeter05MaxAvgDem NegWattsMeter06MaxAvgDem NegVARsMeter04MaxAvgDem NegVARsMeter05MaxAvgDem NegVARsMeter06MaxAvgDem PosWattsMeter07MaxAvgDem PosWattsMeter08MaxAvgDem PosWattsMeter09MaxAvgDem PosVARsMeter07MaxAvgDem PosVARsMeter08MaxAvgDem PosVARsMeter09MaxAvgDem NegWattsMeter07MaxAvgDem NegWattsMeter08MaxAvgDem NegWattsMeter09MaxAvgDem NegVARsMeter07MaxAvgDem NegVARsMeter08MaxAvgDem NegVARsMeter09MaxAvgDem PosWattsMeter10MaxAvgDem PosWattsMeter11MaxAvgDem PosWattsMeter12MaxAvgDem PosVARsMeter10MaxAvgDem PosVARsMeter11MaxAvgDem PosVARsMeter12MaxAvgDem NegWattsMeter10MaxAvgDem NegWattsMeter11MaxAvgDem NegWattsMeter12MaxAvgDem NegVARsMeter10MaxAvgDem NegVARsMeter11MaxAvgDem NegVARsMeter12MaxAvgDem PosWattsMeter13MaxAvgDem PosWattsMeter14MaxAvgDem PosWattsMeter15MaxAvgDem BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF N2 Point Address 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 EIPTagName Flt_XXX[234] Flt_XXX[235] Flt_XXX[236] Flt_XXX[237] Flt_XXX[238] Flt_XXX[239] Flt_XXX[240] Flt_XXX[241] Flt_XXX[242] Flt_XXX[243] Flt_XXX[244] Flt_XXX[245] Flt_XXX[246] Flt_XXX[247] Flt_XXX[248] Flt_XXX[249] Flt_XXX[250] Flt_XXX[251] Flt_XXX[252] Flt_XXX[253] Flt_XXX[254] Flt_XXX[255] Flt_XXX[256] Flt_XXX[257] Flt_XXX[258] Flt_XXX[259] Flt_XXX[260] Flt_XXX[261] Flt_XXX[262] Flt_XXX[263] Flt_XXX[264] Flt_XXX[265] Flt_XXX[266] Flt_XXX[267] Flt_XXX[268] Doc# E204701 DF1 Address F10:234 F10:235 F10:236 F10:237 F10:238 F10:239 F10:240 F10:241 F10:242 F10:243 F10:244 F10:245 F10:246 F10:247 F10:248 F10:249 F10:250 F10:251 F10:252 F10:253 F10:254 F11:000 F11:001 F11:002 F11:003 F11:004 F11:005 F11:006 F11:007 F11:008 F11:009 F11:010 F11:011 F11:012 F11:013 LonName nvoPVAR5MxAv_XXX nvoPVAR6MxAv_XXX nvoNWt4MxAvD_XXX nvoNWt5MxAvD_XXX nvoNWt6MxAvD_XXX nvoNVAR4MxAv_XXX nvoNVAR5MxAv_XXX nvoNVAR6MxAv_XXX nvoPWt7MxAvD_XXX nvoPWt8MxAvD_XXX nvoPWt9MxAvD_XXX nvoPVAR7MxAv_XXX nvoPVAR8MxAv_XXX nvoPVAR9MxAv_XXX nvoNWt7MxAvD_XXX nvoNWt8MxAvD_XXX nvoNWt9MxAvD_XXX nvoNVAR7MxAv_XXX nvoNVAR8MxAv_XXX nvoNVAR9MxAv_XXX nvoPWt10MxAv_XXX nvoPWt11MxAv_XXX nvoPWt12MxAv_XXX nvoPVAR10MxA_XXX nvoPVAR11MxA_XXX nvoPVAR12MxA_XXX nvoNWt10MxAv_XXX nvoNWt11MxAv_XXX nvoNWt12MxAv_XXX nvoNVAR10MxA_XXX nvoNVAR11MxA_XXX nvoNVAR12MxA_XXX nvoPWt13MxAv_XXX nvoPWt14MxAv_XXX nvoPWt15MxAv_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-33 A: Protocol Data Points for EIG Meters PointName PosVARsMeter13MaxAvgDem PosVARsMeter14MaxAvgDem PosVARsMeter15MaxAvgDem NegWattsMeter13MaxAvgDem NegWattsMeter14MaxAvgDem NegWattsMeter15MaxAvgDem NegVARsMeter13MaxAvgDem NegVARsMeter14MaxAvgDem NegVARsMeter15MaxAvgDem PosWattsMeter16MaxAvgDem PosWattsMeter17MaxAvgDem PosWattsMeter18MaxAvgDem PosVARsMeter16MaxAvgDem PosVARsMeter17MaxAvgDem PosVARsMeter18MaxAvgDem NegWattsMeter16MaxAvgDem NegWattsMeter17MaxAvgDem NegWattsMeter18MaxAvgDem NegVARsMeter16MaxAvgDem NegVARsMeter17MaxAvgDem NegVARsMeter18MaxAvgDem PosWattsMeter19MaxAvgDem PosWattsMeter20MaxAvgDem PosWattsMeter21MaxAvgDem PosVARsMeter19MaxAvgDem PosVARsMeter20MaxAvgDem PosVARsMeter21MaxAvgDem NegWattsMeter19MaxAvgDem NegWattsMeter20MaxAvgDem NegWattsMeter21MaxAvgDem NegVARsMeter19MaxAvgDem NegVARsMeter20MaxAvgDem NegVARsMeter21MaxAvgDem PosWattsMeter22MaxAvgDem PosWattsMeter23MaxAvgDem BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADF ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI N2 Point Address 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 1 2 3 4 5 6 7 8 9 10 11 EIPTagName Flt_XXX[269] Flt_XXX[270] Flt_XXX[271] Flt_XXX[272] Flt_XXX[273] Flt_XXX[274] Flt_XXX[275] Flt_XXX[276] Flt_XXX[277] Flt_XXX[278] Flt_XXX[279] Flt_XXX[280] Flt_XXX[281] Flt_XXX[282] Flt_XXX[283] Flt_XXX[284] Flt_XXX[285] Flt_XXX[286] Flt_XXX[287] Flt_XXX[288] Flt_XXX[289] Flt_XXX[290] Flt_XXX[291] Flt_XXX[292] Flt_XXX[293] Flt_XXX[294] Flt_XXX[295] Flt_XXX[296] Flt_XXX[297] Flt_XXX[298] Flt_XXX[299] Flt_XXX[300] Flt_XXX[301] Flt_XXX[302] Flt_XXX[303] Doc# E204701 DF1 Address F11:014 F11:015 F11:016 F11:017 F11:018 F11:019 F11:020 F11:021 F11:022 F11:023 F11:024 F11:025 F11:026 F11:027 F11:028 F11:029 F11:030 F11:031 F11:032 F11:033 F11:034 F11:035 F11:036 F11:037 F11:038 F11:039 F11:040 F11:041 F11:042 F11:043 F11:044 F11:045 F11:046 F11:047 F11:048 LonName nvoPVAR13MxA_XXX nvoPVAR14MxA_XXX nvoPVAR15MxA_XXX nvoNWt13MxAv_XXX nvoNWt14MxAv_XXX nvoNWt15MxAv_XXX nvoNVAR13MxA_XXX nvoNVAR14MxA_XXX nvoNVAR15MxA_XXX nvoPWt16MxAv_XXX nvoPWt17MxAv_XXX nvoPWt18MxAv_XXX nvoPVAR16MxA_XXX nvoPVAR17MxA_XXX nvoPVAR18MxA_XXX nvoNWt16MxAv_XXX nvoNWt17MxAv_XXX nvoNWt18MxAv_XXX nvoNVAR16MxA_XXX nvoNVAR17MxA_XXX nvoNVAR18MxA_XXX nvoPWt19MxAv_XXX nvoPWt20MxAv_XXX nvoPWt21MxAv_XXX nvoPVAR19MxA_XXX nvoPVAR20MxA_XXX nvoPVAR21MxA_XXX nvoNWt19MxAv_XXX nvoNWt20MxAv_XXX nvoNWt21MxAv_XXX nvoNVAR19MxA_XXX nvoNVAR20MxA_XXX nvoNVAR21MxA_XXX nvoPWt22MxAv_XXX nvoPWt23MxAv_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f A-34 A: Protocol Data Points for EIG Meters PointName PosWattsMeter24MaxAvgDem PosVARsMeter22MaxAvgDem PosVARsMeter23MaxAvgDem PosVARsMeter24MaxAvgDem NegWattsMeter22MaxAvgDem NegWattsMeter23MaxAvgDem NegWattsMeter24MaxAvgDem NegVARsMeter22MaxAvgDem NegVARsMeter23MaxAvgDem NegVARsMeter24MaxAvgDem CTDenominator CTNumeratorMeter1 CTNumeratorMeter2 CTNumeratorMeter3 CTNumeratorMeter4 CTNumeratorMeter5 CTNumeratorMeter6 CTNumeratorMeter7 CTNumeratorMeter8 CTNumeratorMeter9 CTNumeratorMeter10 CTNumeratorMeter11 CTNumeratorMeter12 CTNumeratorMeter13 CTNumeratorMeter14 CTNumeratorMeter15 CTNumeratorMeter16 CTNumeratorMeter17 CTNumeratorMeter18 CTNumeratorMeter19 CTNumeratorMeter20 CTNumeratorMeter21 CTNumeratorMeter22 CTNumeratorMeter23 CTNumeratorMeter24 BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI AI BACnet Object ID 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI N2 Point Address 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 EIPTagName Flt_XXX[304] Flt_XXX[305] Flt_XXX[306] Flt_XXX[307] Flt_XXX[308] Flt_XXX[309] Flt_XXX[310] Flt_XXX[311] Flt_XXX[312] Flt_XXX[313] Dev2_XXX[000] Dev2_XXX[001] Dev2_XXX[002] Dev2_XXX[003] Dev2_XXX[004] Dev2_XXX[005] Dev2_XXX[006] Dev2_XXX[007] Dev2_XXX[008] Dev2_XXX[009] Dev2_XXX[010] Dev2_XXX[011] Dev2_XXX[012] Dev2_XXX[013] Dev2_XXX[014] Dev2_XXX[015] Dev2_XXX[016] Dev2_XXX[017] Dev2_XXX[018] Dev2_XXX[019] Dev2_XXX[020] Dev2_XXX[021] Dev2_XXX[022] Dev2_XXX[023] Dev2_XXX[024] Doc# E204701 DF1 Address F11:049 F11:050 F11:051 F11:052 F11:053 F11:054 F11:055 F11:056 F11:057 F11:058 N14:000 N14:001 N14:002 N14:003 N14:004 N14:005 N14:006 N14:007 N14:008 N14:009 N14:010 N14:011 N14:012 N14:013 N14:014 N14:015 N14:016 N14:017 N14:018 N14:019 N14:020 N14:021 N14:022 N14:023 N14:024 LonName nvoPWt24MxAv_XXX nvoPVAR22MxA_XXX nvoPVAR23MxA_XXX nvoPVAR24MxA_XXX nvoNWt22MxAv_XXX nvoNWt23MxAv_XXX nvoNWt24MxAv_XXX nvoNVAR22MxA_XXX nvoNVAR23MxA_XXX nvoNVAR24MxA_XXX nvoCTDen_XXX nvoCTNum1_XXX nvoCTNum2_XXX nvoCTNum3_XXX nvoCTNum4_XXX nvoCTNum5_XXX nvoCTNum6_XXX nvoCTNum7_XXX nvoCTNum8_XXX nvoCTNum9_XXX nvoCTNum10_XXX nvoCTNum11_XXX nvoCTNum12_XXX nvoCTNum13_XXX nvoCTNum14_XXX nvoCTNum15_XXX nvoCTNum16_XXX nvoCTNum17_XXX nvoCTNum18_XXX nvoCTNum19_XXX nvoCTNum20_XXX nvoCTNum21_XXX nvoCTNum22_XXX nvoCTNum23_XXX nvoCTNum24_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc_f SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc A-35 A: Protocol Data Points for EIG Meters PointName PTnumerator PTdenominator Hookup SerialNumberReg1 SerialNumberReg2 SerialNumberReg3 SerialNumberReg4 SerialNumberReg5 SerialNumberReg6 SerialNumberReg7 SerialNumberReg8 PasswordforResetinuse PasswordforConfigurationinuse BACnet Object Type AI AI AI AI AI AI AI AI AI AI AI BI BI BACnet Object ID 559 560 561 562 563 564 565 566 567 568 569 570 571 Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions N2 Data Type ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI ADI N2 Point Address 47 48 49 50 51 52 53 54 55 56 57 58 59 EIPTagName Dev2_XXX[025] Dev3_XXX[000] Dev3_XXX[001] Dev3_XXX[002] Dev3_XXX[003] Dev3_XXX[004] Dev3_XXX[005] Dev3_XXX[006] Dev3_XXX[007] Dev3_XXX[008] Dev3_XXX[009] Byt_XXX[0] Byt_XXX[1] Doc# E204701 DF1 Address N14:025 N15:000 N15:001 N15:002 N15:003 N15:004 N15:005 N15:006 N15:007 N15:008 N15:009 N16:0 N16:1 LonName nvoPTnum_XXX nvoPTden_XXX nvoHookup_XXX nvoSerNum1_XXX nvoSerNum2_XXX nvoSerNum3_XXX nvoSerNum4_XXX nvoSerNum5_XXX nvoSerNum6_XXX nvoSerNum7_XXX nvoSerNum8_XXX nvoPswdReset_XXX nvoPswdCnfg_XXX LonSNVT SNVT_count_inc_f SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc SNVT_count_inc A-36 B: MAC Address DIP Switch Settings B: MAC Address DIP Switch Settings This following table lists the settings for the A Bank of DIP switches, used to set a MAC address. Address A0 A1 A2 A3 A4 A5 A6 A7 0 Off Off Off Off Off Off Off Off 1 On Off Off Off Off Off Off Off 2 Off On Off Off Off Off Off Off 3 On On Off Off Off Off Off Off 4 Off Off On Off Off Off Off Off 5 On Off On Off Off Off Off Off 6 Off On On Off Off Off Off Off 7 On On On Off Off Off Off Off 8 Off Off Off On Off Off Off Off 9 On Off Off On Off Off Off Off 10 Off On Off On Off Off Off Off 11 On On Off On Off Off Off Off 12 Off Off On On Off Off Off Off 13 On Off On On Off Off Off Off 14 Off On On On Off Off Off Off 15 On On On On Off Off Off Off 16 Off Off Off Off On Off Off Off 17 On Off Off Off On Off Off Off 18 Off On Off Off On Off Off Off 19 On On Off Off On Off Off Off 20 Off Off On Off On Off Off Off 21 On Off On Off On Off Off Off 22 Off On On Off On Off Off Off 23 On On On Off On Off Off Off 24 Off Off Off On On Off Off Off 25 On Off Off On On Off Off Off 26 Off On Off On On Off Off Off Off 27 On On Off On On Off Off 28 Off Off On On On Off Off Off 29 On Off On On On Off Off Off 30 Off On On On On Off Off Off 31 On On On On On Off Off Off 32 Off Off Off Off Off On Off Off 33 On Off Off Off Off On Off Off 34 Off On Off Off Off On Off Off 35 On On Off Off Off On Off Off 36 Off Off On Off Off On Off Off 37 On Off On Off Off On Off Off 38 Off On On Off Off On Off Off 39 On On On Off Off On Off Off 40 Off Off Off On Off On Off Off Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 B-1 B: MAC Address DIP Switch Settings Address A0 A1 A2 A3 A4 A5 A6 A7 41 On Off Off On Off On Off Off 42 Off On Off On Off On Off Off 43 On On Off On Off On Off Off 44 Off Off On On Off On Off Off 45 On Off On On Off On Off Off 46 Off On On On Off On Off Off 47 On On On On Off On Off Off 48 Off Off Off Off On On Off Off 49 On Off Off Off On On Off Off 50 Off On Off Off On On Off Off 51 On On Off Off On On Off Off 52 Off Off On Off On On Off Off 53 On Off On Off On On Off Off 54 Off On On Off On On Off Off Off 55 On On On Off On On Off 56 Off Off Off On On On Off Off 57 On Off Off On On On Off Off 58 Off On Off On On On Off Off 59 On On Off On On On Off Off 60 Off Off On On On On Off Off 61 On Off On On On On Off Off 62 Off On On On On On Off Off 63 On On On On On On Off Off 64 Off Off Off Off Off Off On Off 65 On Off Off Off Off Off On Off 66 Off On Off Off Off Off On Off 67 On On Off Off Off Off On Off 68 Off Off On Off Off Off On Off 69 On Off On Off Off Off On Off 70 Off On On Off Off Off On Off 71 On On On Off Off Off On Off 72 Off Off Off On Off Off On Off 73 On Off Off On Off Off On Off 74 Off On Off On Off Off On Off Off 75 On On Off On Off Off On 76 Off Off On On Off Off On Off 77 On Off On On Off Off On Off 78 Off On On On Off Off On Off 79 On On On On Off Off On Off 80 Off Off Off Off On Off On Off 81 On Off Off Off On Off On Off 82 Off On Off Off On Off On Off 83 On On Off Off On Off On Off 84 Off Off On Off On Off On Off 85 On Off On Off On Off On Off 86 Off On On Off On Off On Off 87 On On On Off On Off On Off 88 Off Off Off On On Off On Off 89 On Off Off On On Off On Off Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 B-2 B: MAC Address DIP Switch Settings Address A0 A1 A2 A3 A4 A5 A6 A7 90 Off On Off On On Off On Off 91 On On Off On On Off On Off 92 Off Off On On On Off On Off 93 On Off On On On Off On Off 94 Off On On On On Off On Off 95 On On On On On Off On Off 96 Off Off Off Off Off On On Off 97 On Off Off Off Off On On Off 98 Off On Off Off Off On On Off 99 On On Off Off Off On On Off 100 Off Off On Off Off On On Off 101 On Off On Off Off On On Off 102 Off On On Off Off On On Off 103 On On On Off Off On On Off 104 Off Off Off On Off On On Off 105 On Off Off On Off On On Off 106 Off On Off On Off On On Off 107 On On Off On Off On On Off 108 Off Off On On Off On On Off 109 On Off On On Off On On Off 110 Off On On On Off On On Off 111 On On On On Off On On Off 112 Off Off Off Off On On On Off 113 On Off Off Off On On On Off 114 Off On Off Off On On On Off 115 On On Off Off On On On Off 116 Off Off On Off On On On Off 117 On Off On Off On On On Off 118 Off On On Off On On On Off 119 On On On Off On On On Off 120 Off Off Off On On On On Off 121 On Off Off On On On On Off 122 Off On Off On On On On Off 123 On On Off On On On On Off 124 Off Off On On On On On Off 125 On Off On On On On On Off 126 Off On On On On On On Off Off 127 On On On On On On On 128 Off Off Off Off Off Off Off On 129 On Off Off Off Off Off Off On 130 Off On Off Off Off Off Off On 131 On On Off Off Off Off Off On 132 Off Off On Off Off Off Off On 133 On Off On Off Off Off Off On 134 Off On On Off Off Off Off On 135 On On On Off Off Off Off On 136 Off Off Off On Off Off Off On 137 On Off Off On Off Off Off On 138 Off On Off On Off Off Off On Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 B-3 B: MAC Address DIP Switch Settings Address A0 A1 A2 A3 A4 A5 A6 A7 139 On On Off On Off Off Off On 140 Off Off On On Off Off Off On 141 On Off On On Off Off Off On 142 Off On On On Off Off Off On 143 On On On On Off Off Off On 144 Off Off Off Off On Off Off On 145 On Off Off Off On Off Off On 146 Off On Off Off On Off Off On On 147 On On Off Off On Off Off 148 Off Off On Off On Off Off On 149 On Off On Off On Off Off On 150 Off On On Off On Off Off On 151 On On On Off On Off Off On 152 Off Off Off On On Off Off On 153 On Off Off On On Off Off On 154 Off On Off On On Off Off On 155 On On Off On On Off Off On 156 Off Off On On On Off Off On 157 On Off On On On Off Off On 158 Off On On On On Off Off On On 159 On On On On On Off Off 160 Off Off Off Off Off On Off On 161 On Off Off Off Off On Off On 162 Off On Off Off Off On Off On 163 On On Off Off Off On Off On 164 Off Off On Off Off On Off On 165 On Off On Off Off On Off On 166 Off On On Off Off On Off On 167 On On On Off Off On Off On 168 Off Off Off On Off On Off On 169 On Off Off On Off On Off On 170 Off On Off On Off On Off On 171 On On Off On Off On Off On 172 Off Off On On Off On Off On 173 On Off On On Off On Off On 174 Off On On On Off On Off On 175 On On On On Off On Off On 176 Off Off Off Off On On Off On 177 On Off Off Off On On Off On 178 Off On Off Off On On Off On 179 On On Off Off On On Off On 180 Off Off On Off On On Off On 181 On Off On Off On On Off On 182 Off On On Off On On Off On 183 On On On Off On On Off On 184 Off Off Off On On On Off On 185 On Off Off On On On Off On 186 Off On Off On On On Off On 187 On On Off On On On Off On Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 B-4 B: MAC Address DIP Switch Settings Address A0 A1 A2 A3 A4 A5 A6 A7 188 Off Off On On On On Off On 189 On Off On On On On Off On 190 Off On On On On On Off On 191 On On On On On On Off On 192 Off Off Off Off Off Off On On 193 On Off Off Off Off Off On On 194 Off On Off Off Off Off On On 195 On On Off Off Off Off On On 196 Off Off On Off Off Off On On 197 On Off On Off Off Off On On 198 Off On On Off Off Off On On 199 On On On Off Off Off On On 200 Off Off Off On Off Off On On 201 On Off Off On Off Off On On 202 Off On Off On Off Off On On 203 On On Off On Off Off On On 204 Off Off On On Off Off On On 205 On Off On On Off Off On On 206 Off On On On Off Off On On 207 On On On On Off Off On On 208 Off Off Off Off On Off On On 209 On Off Off Off On Off On On 210 Off On Off Off On Off On On 211 On On Off Off On Off On On 212 Off Off On Off On Off On On 213 On Off On Off On Off On On 214 Off On On Off On Off On On 215 On On On Off On Off On On 216 Off Off Off On On Off On On 217 On Off Off On On Off On On 218 Off On Off On On Off On On On 219 On On Off On On Off On 220 Off Off On On On Off On On 221 On Off On On On Off On On 222 Off On On On On Off On On 223 On On On On On Off On On 224 Off Off Off Off Off On On On 225 On Off Off Off Off On On On 226 Off On Off Off Off On On On 227 On On Off Off Off On On On 228 Off Off On Off Off On On On 229 On Off On Off Off On On On 230 Off On On Off Off On On On 231 On On On Off Off On On On 232 Off Off Off On Off On On On 233 On Off Off On Off On On On 234 Off On Off On Off On On On 235 On On Off On Off On On On 236 Off Off On On Off On On On Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 B-5 B: MAC Address DIP Switch Settings Address A0 A1 A2 A3 A4 A5 A6 A7 237 On Off On On Off On On On 238 Off On On On Off On On On 239 On On On On Off On On On 240 Off Off Off Off On On On On 241 On Off Off Off On On On On 242 Off On Off Off On On On On 243 On On Off Off On On On On 244 Off Off On Off On On On On 245 On Off On Off On On On On 246 Off On On Off On On On On 247 On On On Off On On On On 248 Off Off Off On On On On On 249 On Off Off On On On On On 250 Off On Off On On On On On 251 On On Off On On On On On 252 Off Off On On On On On On 253 On Off On On On On On On 254 Off On On On On On On On 255 On On On On On On On On Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions Doc# E204701 B-6
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Electro Industries Create Date : 2014:09:10 10:35:40Z Modify Date : 2014:09:10 11:44:30-04:00 Has XFA : No Language : en XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : FrameMaker 12.0 Metadata Date : 2014:09:10 11:44:30-04:00 Producer : Acrobat Distiller 10.1.10 (Windows) Format : application/pdf Title : ProtoCom_ProtoCom-Lon User Manual V.1.02 Creator : Electro Industries Document ID : uuid:e422d7d4-0515-4b3c-92db-d39cd0f30bae Instance ID : uuid:8b1d2dd6-a633-4eae-bd88-67ad0eaf53df Page Mode : UseOutlines Page Count : 104EXIF Metadata provided by EXIF.tools