Qolsys QS1100 wireless door/window sensor to be used in the Qolsys IQ home security system User Manual

Qolsys, Inc. wireless door/window sensor to be used in the Qolsys IQ home security system

User Manual

Download: Qolsys QS1100 wireless door/window sensor to be used in the Qolsys IQ home security system User Manual
Mirror Download [FCC.gov]Qolsys QS1100 wireless door/window sensor to be used in the Qolsys IQ home security system User Manual
Document ID2723278
Application IDpugOqL/P84ItCia5wS+z/g==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize30.59kB (382394 bits)
Date Submitted2015-08-24 00:00:00
Date Available2015-08-24 00:00:00
Creation Date2017-09-17 05:21:16
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-09-17 05:21:16
Document TitleUser Manual

IQ DOOR/WINDOW- INSTALLATION MANUAL
IQ DOOR/WINDOW
The Qolsys IQ Door/Window is a sleek, highperformance wireless sensor that detects opening
and closing of doors, windows and anything else
which opens and closes (drawers, cabinets, etc). It
works seamlessly with the Qolsys IQPanel.
TECHNICAL SPECIFICATIONS
Wireless signal range: 600ft (200M),open air.
Code outputs: tamper, tamper restore, alarm (primary open),
alarm restore (primary close), external alarm (secondary
wired open), external restore (secondary wired closed), low
battery.
Transmitter frequency : 319.5MHZ
Unique code ID
Supervisory keep-alive interval: 70 minutes.
RF output power 91.1dBuV +/- 5% at 3m
PRODUCT FEATURES
PARTS INCLUDED
1 Door/Window Sensor
1 Magnet
6 screws
1 large strip of double sided adhesive
1 small strip of double sided adhesive
•Low profile
•Supports one or two doors, windows, etc.
•Primary wireless magnet contact and secondary wired
contact
•Internal or external reed switch
•Easy, wire-free installation
•Secondary (optional) sensor (external wired Door/Window
sensor)
•Advanced circuit technology resulting in ultra-low power
consumption
•Easy to install Batteries
•Over 5 years of battery life
•Tamper Detection
•Supervisory health messaging
•Sensor Open and Close detection
QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 1 OF 6
© Last revised 2/27/15 All rights reserved
IQ DOOR/WINDOW- INSTALLATION MANUAL
GUIDELINES
•Mount the sensor on the door
frame and the magnet on the
door. If the sensor is used on
double doors, mount the sensor
on the least‐used door and the
magnet on the most‐used door.
PLACEMENT AND SPACING
Be sure to align the triangle guides on the sensor and magnet as shown. This will
enable the proper contact between the sensor and magnet. When closed, the
magnet should be within .4” of the sensor for optimum sensitivity.
•If possible, locate sensors
within 100 ft. (30 m) from the
panel.
•While a transmiAer may have a
range of 600 E. (200 m) or
more out in the open, the
environment at the installation
site can have a significant effect
on transmitter range. Some‐
Jmes a change in sensor
orientaJon can help overcome
adverse wireless condiJons.
•Make sure the alignment arrow
on the magnet points to the
alignment mark on the sensor.
•Place sensors at least 6 in.
(15.24 cm) above the floor to
avoid damaging them.
•Avoid mounJng sensors in
areas where they will be
exposed to moisture or where
the sensor operating
temperature range
of 0 to 120°F (0 to 49°C) will be
exceeded.
BaAery
retenJon
clips
Tamper switch
External
contact
header
Please note: the sensor will not operate the reed switch and external contact header
simultaneously.
BATTERY ACTIVATION
To activate the batteries in the sensor, remove the cover and pull out the plastic tabs
between the batteries and the contacts.
•Use spacers (not included) to
keep sensors and magnets
away from metal or metallic
surfaces such as foil wallpaper.
•Avoid mounting sensors in
areas with a large quantity of
metal or electrical wiring, such
as a furnace or uJlity room
QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 2 OF 6
© Last revised 2/27/15 All rights reserved
IQ DOOR/WINDOW- INSTALLATION MANUAL
MOUNTING WITH PROVIDED ADHESIVE
•Remove backing on one side of the large double‐sided tape and sJck the
exposed side on the back of the sensor as shown.
•Remove the other side of the large double‐sided tape and mount the
device according to the installaJon instrucJons
•Remove the backing one side of the small double‐sided tape and place on
back of magnet
•Lineup the magnet with the sensor using the arrows shown on each device
respecJvely. Ensure the sensor and magnet are not separated more than
0.4 inches as shown.
•Remove the second side of the double‐sided tape and secure the magnet.
MOUNTING WITH PROVIDED HARDWARE
•Remove the back of the sensor by pressing on the tab and
pulling the cover off
•Place the base of the sensor on the appropriate surface and
use 4 of the supplied screws to secure the mounJng plate to
the chosen locaJon
•To secure the magnet, remove the mounJng plate by
prying it off the magnet casing.
•Be sure the arrows on the top of the casing align with the
arrows on the sensor casing. The sensor and magnet should
not be mounted more than 0.4 inches apart.
•Use the 2 remaining screws provided to secure the magnet
mounJng plate in the proper locaJon. Clip the magnet
casing back into place once the plate is secure.
QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 3 OF 6
© Last revised 2/27/15 All rights reserved
Push to remove
sensor cover
IQ DOOR/WINDOW- INSTALLATION MANUAL
PROGRAMMING THE IQ DOOR/WINDOW
The following steps describe general guidelines for programming (learning) the sensor into the IQ Panel. Refer to
the IQ Panel's installation instructions for complete programming details.
From the home screen of
the IQ panel, touch the
“Settings” icon
Enter the installer passcode.
Default installer passcode is 1111
Touch the “Installation” app
Touch the “Security Sensors” app
Touch the “AutoLearn
Sensor” app
Tamper the sensor by pressing the
tab and liEing off the cover.
A chime will sound
Touch “Ok”
Check the auto-populated fields to ensure accuracy.
Customize device settings as desired.
Create custom names by selecting “Sensor name” and
choosing “Custom description.” A keyboard will
appear, allowing you to type the name of your choice
into the field.
10
Click “Add” to complete the process
QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 4 OF 6
© Last revised 2/27/15 All rights reserved
IQ DOOR/WINDOW- INSTALLATION MANUAL
BATTERY REPLACEMENT
Push to remove
sensor cover
To replace batteries:
•Push tab on side of sensor and lift off cover.
•Place fingernail or small screwdriver under the battery and gently lift
up. The battery should release easily. Remove old battery. Replace
with a new battery by putting one end under the golden battery
retention clip. Gently push toward the opposite side until the the
battery snaps into place under the black plastic.
•Repeat this process for the second battery.
•Close cover by snapping the cover back onto the sensor.
BATTERY TYPE
BaAery
retenJon clips
Tamper
switch
3V CR2032 Lithium
(2 batteries per sensor)
5+ years battery life
External
contact
header
ENVIRONMENTAL CHARACTERISTICS
Operating Temperature: -10C~50C
Relative Humidity: 5-95% Non-Condensing
Storage Temperature: -40-80C
PHYSICAL SPECIFICATIONS
Sensor: 3.25H x 1.3W x 1D in. (8x3x1.5 cm)
Magnet: 1.3H x 0.435W x 0.312D in. (3.3 x 1.1 x 0.79 cm)
SUPPORT
GOT QUESTIONS?
CONTACT TECH SUPPORT
TechSupport@Qolsys.com
QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 5 OF 6
© Last revised 2/27/15 All rights reserved
IQ DOOR/WINDOW- INSTALLATION MANUAL
IMPORTANT INFORMATION
15.21
§ 15.21 Information to user.
The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes
or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
15.105(b)
§ 15.105 Information to the user.
(b) NOTE: This equipment has been tested and
found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
RSS-GEN Section 8.4
8.4 User manuals for licence-exempt radio apparatus shall contain the following text, or an equivalent notice that shall be
displayed in a conspicuous location, either in the user manual or on the device, or both:
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
Document#: IQDW-IM-02-15
Revision#: 2/27/15
Issue Date: FEB 2015
Qolsys Product #: QS-1100-P01
Firmware : 0A_20121130
Conforms to ANSI/UL Std. 634
Certified to ULC Sub. C634
Qolsys Inc. proprietary.
Reproduction without permission is not permitted.
QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 6 OF6
© Last revised 2/27/15 All rights reserved

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 6
Warning                         : Bad Info reference
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AAJXQS1100

Navigation menu