R tron SNIDEN25 iDen Mini Wireless Repeater User Manual

R-tron Inc. iDen Mini Wireless Repeater

Contents

Part 1

Download: R tron SNIDEN25 iDen Mini Wireless Repeater User Manual
Mirror Download [FCC.gov]R tron SNIDEN25 iDen Mini Wireless Repeater User Manual
Document ID788599
Application IDpHz6i2fNPD+aPjkYWGS/YQ==
Document DescriptionPart 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize311.77kB (3897081 bits)
Date Submitted2007-05-04 00:00:00
Date Available2007-05-07 00:00:00
Creation Date2007-05-02 15:58:24
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2007-05-02 20:10:56
Document Titleuntitled

iDEN MINI
(RSN-iDEN-25)
User’s Manual
R-tron Inc.
RF EXPOSURE INFORMATION
A minimum separation distance of 7.9 inches(20cm) must be maintained between the
user and the external antenna of repeater to satisfy FCC RF exposure requirements.
For more information about RF exposure, please visit the FCC website at www.fcc.gov
CAUTION
This equipment is indoor use and all the communication
wiring are limited to inside of the building.
User’s Manual
-2-
iDEN MINI
This document describes the specifications, installation and operation of iDEN MINI.
Hardware and software mentioned in this document are subject to continuous development and
improvement. Consequently, there may be minor discrepancies between the information in the
document and the performance and design of the product. Specifications, dimensions and other
statements mentioned in this document are subject to change without notice.
R-tron Inc. 6402 College Boulevard Overland Park, KS 66211
Phone: +1-913-344-9977, 1-888-31R-TRON, Fax: +1-913-344-9988,
Internet: www.r-tron.com
R-tron is registered trademarks of R-tron Inc. Other products and company names mentioned herein this
manual might be trade marks or trade names of their respective owners.
This document or parts of it may not be reproduced without the written permission of R-tron Inc.
Infringements will be prosecuted. All rights reserved
Copyright © R-tron Inc. 2000-2007
User’s Manual
-3-
iDEN MINI
Contents
Abbreviations .......................................................................................................................6
1.
Introduction ...........................................................................................................7
2.
Description.............................................................................................................9
2.1
System Specifications ....................................................................................................... 9
2.1.1. Electrical Specifications .......................................................................................... 9
2.1.2. Mechanical Specifications .................................................................................... 10
2.2
Sub Unit Overview............................................................................................................11
2.2.1. Block Diagram ...................................................................................................... 12
2.2.2. UDC Module ......................................................................................................... 13
2.2.3. Multiplexer ............................................................................................................ 14
2.2.4. MCU (Main Control Unit) ...................................................................................... 15
2.2.5. Power Supply ....................................................................................................... 16
2.2.6. HPA (High Power Amplifier) .................................................................................. 17
3.
Hardware Installation............................................................................................ 18
3.1
3.2
3.3
3.4
3.5
4.
Check List of Items .......................................................................................................... 18
Mounting .......................................................................................................................... 19
Grounding ........................................................................................................................ 20
RF Cable Connection ...................................................................................................... 20
Power Up ......................................................................................................................... 21
Command and Control through the Hyper Terminal ................................................ 22
4.1 Setting for Command and Control through the Hyper Terminal ........................................... 22
4.2 Command and Control through the Hyper Terminal ............................................................ 25
5.
Troubleshooting.................................................................................................... 30
5.1
5.2
5.3
User’s Manual
RF Connection Check ..................................................................................................... 30
Power Connection ........................................................................................................... 30
Red Light on the Alarm LED ............................................................................................ 31
-4-
iDEN MINI
Figures
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
Figure
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
User’s Manual
R-tron iDEN MINI ...................................................................................................... 7
Overview: Service ..................................................................................................... 8
Dimension of iDEN MINI .......................................................................................... 10
Internal View of iDEN MINI...................................................................................... 11
Block Diagram ........................................................................................................ 12
UDC Module ........................................................................................................... 13
Multiplexer ............................................................................................................. 14
Main Control Unit .................................................................................................... 15
Power Supply.......................................................................................................... 16
HPA(High Power Amplifier) ................................................................................... 17
Items .................................................................................................................. 18
Mounting ............................................................................................................ 19
Grounding ........................................................................................................... 20
Configuration: RF Cable Connection ...................................................................... 21
Power Cord Connection ........................................................................................ 21
Local connection to the iDEN MINI ....................................................................... 22
LEDs Off ............................................................................................................. 30
AC power cord Check ........................................................................................... 31
Red Light on Alarm LED ....................................................................................... 31
-5-
iDEN MINI
Abbreviations
Abbreviations used in this manual, in iDEN Add-On Filter Box.
AC
ANT
CDMA
DC
GND
GUI
iDEN
LED
PSU
RF
TEMP
VSWR
User’s Manual
Alternating Current
Antenna
Code Division Multiple Access
Direct Current
Grounding
Graphic User Interface
Integrated Digital Enhanced Network
Light Emitting Diode
Power Supply Unit
Radio Frequency
Temperature
Voltage Standing Wave Ratio
-6-
iDEN MINI
1. Introduction
Ground rod
Donor Antenna Port
Service Antenna Port
AC Power Socket
& Switch
Status LEDs
RJ-45 (network) jack
Figure 1.
R-tron iDEN MINI
iDEN MINI repeater is used to fill out areas in iDEN mobile systems, such
as base station fringe areas, business and industrial buildings, etc.
iDEN MINI receives signals from a base station, amplifies and
retransmits the signals to mobile stations. Also it receives, amplifies and
retransmits signals in the opposite direction. Both directions are served
simultaneously with the following features:
User’s Manual
„
7MHz or 18MHz-bandwidth service @ 800MHz’s
„
5MHz-bandwidth service @ 900MHz’s
„
Band Shifting @ 800MHz’s and 900MHz’s
„
Roll Offs: 65 dBc at 0.5 MHz outside pass-band
-7-
iDEN MINI
Figure 2.
User’s Manual
Overview: Service
-8-
iDEN MINI
2. Description
2.1 System Specifications
2.1.1. Electrical Specifications
Parameter
Selectable
Bandwidth
DL & UL
18MHzbandwidth
DL
7MHzbandwidth
18MHzbandwidth
UL
7MHzbandwidth
5MHzbandwidth
Roll off
DL & UL
Gain ripple
Output
Power
Delay
VSWR
User’s Manual
In-band BW:18M
In-band BW:7.0M
In-band BW:5M
851~869MHz
850.8~868.8MHz
850.6~868.6MHz
862~869MHz
861.8~868.8MHz
861.6~868.6MHz
935~940MHz
934.8~939.8MHz
934.6~939.6MHz
806~824MHz
805.8~823.8MHz
805.6~823.6MHz
817~824MHz
816.8~823.8MHz
816.6~823.6MHz
896~901MHz
895.8~900.8MHz
895.6~900.6MHz
≤65dBc
≤65dBc
@Fedge+/-500KHz @Fedge+/-500KHz
±1.5dB (Typical)
DL & UL
40dB to 65dB
DL & UL
25dBm
DL & UL
DL & UL
8.0µs Max.
1.5Max.
Rx
Noise Figure
Input Range
iDEN 900
5MHzbandwidth
Frequency
Selection
Gain
iDEN 800
DL & UL
5dB Max. (65dB Gain)
12dB Max. (40dB Gain)
-30dBm Max.
Power supply
110V~125V, 60Hz typical
Operating temperature
Storage temperature
Consumption power
*-10℃~ 50℃
-20℃~60℃
≤94W
-9-
iDEN MINI
2.1.2. Mechanical Specifications
900MHz
TX MON.
900MHz
RX MON.
800MHz
TX MON.
SERVICE
ANTENNA
MADE IN KOREA
T his device complies with part 15 of the FCC rules.
Operation is subject to the condition that this device
n ot cause harmful interference.
800MHz
RX MON.
DONOR
ANTENNA
AC IN
110 -125V ~
: R-tron lnc.
Weight
MAKER
Size
E258109
I.T .E
31CY
Specification
N-female x 2, SMA-female x 4
18.9 X13.78 X 7.22(Inch),
480 X 350 X 183.5(mm)
24kg (52.912lbs)
MODEL
: RSP-AID-001
POWER
: 110V ~ , 50/60Hz , 2A
COMPLIES WITH PART 96, FCC RULES.
FCC REG. NO.
SERIAL NO. / DATE :
Parameter
RF connectors
ALARM
LAN
DANGER
RISK OF ELECTRIC SHOCK
Figure 3.
User’s Manual
Dimension of iDEN MINI
-10-
iDEN MINI
2.2 Sub Unit Overview
iDEN MINI is composed of the following sub units:
„
UDC(Up Down Converter)
„
HPAs(High Power Amplifiers)
„
Multiplexer
„
Main Control Unit (MCU)
„
Power Supply Unit (PSU)
„
EMI Filter
Figure 4.
User’s Manual
Internal View of iDEN MINI
-11-
iDEN MINI
2.2.1. Block Diagram
The following, Figure 5, explains how the iDEN MINI serves signals.
Figure 5.
User’s Manual
Block Diagram
-12-
iDEN MINI
2.2.2. UDC Module
The UDC Module is basically a bi-directional amplifier that sharply filters
out unwanted noise.
Figure 6.
User’s Manual
UDC Module
-13-
iDEN MINI
2.2.3. Multiplexer
A multiplexer is a device that combines two or more signals onto a
common channel or medium to increase its transmission efficiency.
Figure 7.
User’s Manual
Multiplexer
-14-
iDEN MINI
2.2.4. MCU (Main Control Unit)
MCU is the control unit of iDEN MINI. It controls and monitors operational
parameters. It also generates alarms, an event log and many other
functions of the iDEN MINI.
Figure 8.
Main Control Unit
Pin Map
User’s Manual
Port
Connected to
J1
MCU Vcc(+6V)
J3
USB Port(Manufacturer use only)
J4
PSU Alarms
J5
Door Alarm
J6
Status LEDs
J7
iDEN 800 PLL,B/S,OUT DET
J8
iDEN 900 PLL,B/S,OUT DET
J9
Tx HPA
J10
Rx HPA
J11
RJ-45 jack
-15-
iDEN MINI
2.2.5. Power Supply
The Power Supply Unit (PSU) supplies a steady DC power to iDEN MINI
by drawing power from the general in-wall AC outlets
Figure 9.
Power Supply
Specifications
Item
Operating
Temp
Humidity
20%~90%RH
Cooling method
Natural air
Environmental
User’s Manual
Specifications
-10℃~50℃
Voltage
AC110~125V
Current
5A Max / 6V, 12V, 27VDC
Frequency
Leakage Current
50~60Hz typ
0.5mA max.@110V AC
-16-

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 16
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:609629b3-dc48-46b8-b4e5-ffe7ad44f3ab
Modify Date                     : 2007:05:02 20:10:56+09:00
Create Date                     : 2007:05:02 15:58:24+09:00
Metadata Date                   : 2007:05:02 20:10:56+09:00
Document ID                     : uuid:18746b04-bda6-4ea6-8f00-2f9f72194fa5
Format                          : application/pdf
Title                           : untitled
Producer                        : Acrobat Distiller 6.0 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: STESNIDEN25

Navigation menu