RESEARCH INSTRUMENTS 670807 RlWITNESS EMBRYOLOGY HEATED PLATE User Manual Users manual
RESEARCH INSTRUMENTS LTD RlWITNESS EMBRYOLOGY HEATED PLATE Users manual
Contents
- 1. User manual
- 2. Users manual
- 3. Installation manual
Users manual
User Manual RI WITNESS™ Embryology Heated Plate +44 (0) 1737 243869 | customerservice@origio.com | origio.com Research Instruments Ltd, Bickland Industrial Park, Falmouth, Cornwall TR11 4TA, UK Document 6-70-807UM | DRF 3728 | Issue 5 | 1 December 2017 0120 only Contents Research Instruments Ltd CONTENTS SECTION 1 - PREFACE SECTION 2 - INTRODUCTION TO RI WITNESS Indications for Use for RI Witness Embryology Heated Plate Contraindications: Applicable Part Numbers Related Documents Compatibility Installation SECTION 3 - SAFETY WARNINGS Safety/Information Symbols Safety and Reliability Temperature Safety RFID Reader Environment Startup / Shutdown Procedure Guidance and Manufacturer’s Declaration (Part 15 of FCC) — Electromagnetic Emissions Guidance and Manufacturer’s Declaration (IEC 60601-1-2) — Electromagnetic Emissions Guidance and Manufacturer’s Declaration — Electromagnetic Immunity Guidance and Manufacturer’s Declaration — Electromagnetic Immunity SECTION 4 - PRODUCT OVERVIEW Embryology Heated Plate RI Witness Embryology Heated Plate Specification Table 10 SECTION 5 - RI WITNESS BASIC OPERATION 11 Startup Procedure 11 Shutdown Procedure 11 Connecting to the Software 11 User Interface 11 Operator Position 12 Research Instruments Ltd Contents CONTENTS Achieving the Correct Sample Temperature 12 Changing the Temperature Setpoint Using the Device 13 Changing the Temperature Setpoint Using a PC and RI Witness WorkArea Software 13 Temperature Calibration 14 ITO Glass Window Calibration Using Built-In User Interface 14 Full 5-channel Calibration Using PC and RI Witness Work Area Software 15 Tube Reader Antenna Accessory 16 SECTION 6 - TROUBLESHOOTING 17 Alarms and System Status 18 Audible Alarms 18 Alarm System Testing 19 Alarm Conditions Codes 19 SECTION 7- CARE AND MAINTENANCE 23 Cleaning23 SECTION 8 - REPAIRS AND RETURNS 24 Reuse Statement 24 RI Repairs System 24 Product Disposal (European Union) 24 RI Returns System 24 Contact Details 24 Obligation to Inform 24 Feedback 24 Section 1 Preface Research Instruments Ltd SECTION 1 - PREFACE Thank you for choosing RI Witness. This manual provides all necessary information to use RI Witness Embryology Heated Plate and should be read in conjunction with any manuals provided with other RI Witness hardware or software components that you are using. The system should be operated by trained personnel only. All sections of this manual should be read and understood fully before any operation of the system. Please see the Intended Use for more information. If the operator is unsure of any of the information contained in this manual they should contact Research Instruments or an appointed representative before attempting to use this equipment. In no event does Research Instruments Ltd (RI) assume the liability for any technical or editorial errors of commission, or omission; nor is RI liable for direct, indirect, incidental, or consequential damages arising out of the use or inability to use this manual. The information in this manual is current at the time of publication. Our commitment to product improvement requires that we reserve the right to change equipment, procedures and specifications at any time. The latest version of the User Manual can be downloaded from software.research-instruments.com. The RI Witness manual belongs with the RI Witness system and should be passed on with the system if relocated to another clinic. The use of ™ in this manual indicates a trademark of Research Instruments Ltd. Any other brand names, referred to in this manual, are trademarks of their respective owners. © This manual is protected by copyright, all rights reserved, and no part here of may be photocopied or reproduced in any form without the prior written consent of RI. This indicates cautionary text which should be followed to avoid injury to users or damage to samples. The system should be operated by qualified and trained personnel only. Section 2 Research Instruments Ltd Introduction SECTION 2 - INTRODUCTION TO RI WITNESS Indications for Use for RI Witness Embryology Heated Plate To maintain the temperature of human reproductive tissue such as oocytes and embryos through an assisted reproduction (AR) cycle. only 0120 Contraindications: This device is not intended to be exposed to known sources of electromagnetic interference (EMI) with medical devices such as diathermy, CT, MRI, RFID (except other RI Witness RFID components) and electromagnetic security systems, eg metal detectors and electronic article surveillance systems. Applicable indications for use are subject to the regulations of the country into which the device is sold. Availability of RI Witness for clinical use is dependent on the regulatory approval status of RI Witness within the country the device is intended to be sold into. Applicable Part Numbers Part Number Description 6-70-807* RI Witness Embryology Heated Plate 6-70-809 RI Witness Tube Reader * 6-70-807 can be supplied in several configurations depending on the required mounting type, eg flush fitted or sit on top. Related Documents 6-7-121UM RI Witness WorkArea Software Manual 6-7-122UM RI Witness Manager Software Manual Compatibility RI Witness is used in conjunction with the following: • Essential medical devices, eg dishes and tubes, maybe AR or non-AR specific. • Non-essential medical devices, eg safety cabinets, incubators, micromanipulators, lasers. • Non medical devices (general laboratory equipment), eg work benches, microscopes, PCs. This device has RFID reader capability. If it is the intention that it be employed in a clinical lab, we recommend its use alongside other medical devices and that the performance of these medical devices be monitored for potential effects of EMI disturbances, and reported when appropriate. Installation Installations of the RI Witness Embryology Heated plate should be carried out by a RI technician or other RI authorised personnel. Incorrect installation could result in overall poor performance. Section 3 Safety Warnings Research Instruments Ltd SECTION 3 - SAFETY WARNINGS This symbol indicates cautionary text which should be followed to avoid injury to users or damage to samples. The system should be operated by qualified and trained personnel only. DO NOT disassemble or modify any part of the RI Witness Embryology Heated plate, or substitute any component for any other. Doing so may result in damage to samples. This voids the warranty and/or service contract. ONLY use the power cable and power supply adaptor supplied with the system. The cable to the power supply is the ‘disconnect device’ for this equipment. To remove all electrical power from this product, disconnect the power cable from the electrical outlet. Equipment should be positioned so as to allow easy access to the power cable. The appliance coupler or mains plug is used as the disconnect and must remain readily operable. WARNING To avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth. WARNING Not to be used in a patient environment. WARNING Refer to Guidance and Manufacturer’s Declaration Tables in this section of the User Manual for guidance on the environment suitable for this device. WARNING The temperature of the plate should not be more than 1.5ºC from the displayed temperature at any time. A temperature of more than 1.5ºC will cause the temperature inside the dish to change more rapidly and samples are at risk of overheating. In this instance samples should be removed from the plate immediately. We recommend the plate temperature be monitored periodically using a calibrated thermocouple thermometer. WARNING Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. WARNING There are no replaceable parts supplied with this device. Should any parts need to be replaced, contact RI or your distributor. WARNING Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. WARNING Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the Embryology Heated Plate, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result. Section 3 Research Instruments Ltd Safety Warnings Safety/Information Symbols Symbol Meaning Do not dispose of product with normal waste. In accordance with Annex II of the European Medical Device Directive 93/42/EEC, as amended by Directive 2007/47/EC under the supervision of notified body No.0120, SGS, UK Ltd. In accordance with the European Directive for R&TTE, Directive 1999/5/EC. Indicates the medical device manufacturer. Indicates the date of manufacture. Indicates the need for the user to consult the instructions for use for important cautionary information such as warnings and precautions that cannot, for a variety of reasons, be presented on the medical device itself. Consult instructions for use. SN Only REF The five digit number is a unique identifier assigned to the product. Caution: US Federal law restricts this device for sale to or on the order of a licensed healthcare practitioner. Indicates the reference number. Section 3 Safety Warnings Research Instruments Ltd Safety and Reliability Please read this manual carefully and follow the instructions to ensure that the system will work safely and reliably. Temperature Safety Safety is the responsibility of the laboratory. Risk assessment and working practices should comply with local regulatory policies. A warning triangle will be displayed on the work area touch screen and the status LED on the device user interface will display a yellow status alarm if the currently selected temperature cannot be maintained. Gently place your hand on the heated surface to verify that the temperature is appropriate for use. As with all heating systems, it is advisable to perform a periodic check of temperatures using a calibrated thermocouple thermometer. RFID Reader Environment An RI Witness system uses Radio Frequency Identification (RFID) readers to monitor a work area. Readers detect RFID tagged containers that are placed in the work area. The performance of RFID tag detection may be compromised by proximity of metal objects or electrical equipment Do not place metal objects near reader. Do not place electrical equipment near reader. Startup / Shutdown Procedure RI Witness hardware may be damaged by incorrect startup and shutdown procedures. “Section 5 - RI Witness Basic Operation” on page 11 describes the recommended startup and shutdown procedure for the RI Witness Embryology Heated Plate. Section 3 Research Instruments Ltd Safety Warnings Guidance and Manufacturer’s Declaration (Part 15 of FCC) — Electromagnetic Emissions Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the Federal Communications Commision (FCC) Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense. Note: This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. Guidance and Manufacturer’s Declaration (IEC 60601-1-2) — Electromagnetic Emissions RI Witness is intended for use in the electromagnetic environment specified below. The customer or the user of RI Witness should ensure that it is used in such an environment. Emissions test RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions EN 61000-3-2 Compliance Electromagnetic environment guidance Group 2 RI Witness must emit electromagnetic energy in order to perform its intended function. Nearby electronic equipment may be affected. Class B Class A Voltage fluctuations/ flicker emissions RI Witness is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Complies EN 61000-3-3 Section 3 Safety Warnings Research Instruments Ltd USA Only Compliance with the emissions requirements of CISPR 22 Class A requires the following warning: “This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.” Guidance and Manufacturer’s Declaration — Electromagnetic Immunity IMMUNITY Test IEC 60601 Test level Compliance level Electromagnetic environment - guidance Electrostatic discharge (ESD) ± 8 kV contact ± 8 kV contact ± 15 kV air ± 15 kV air Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%. IEC 61000-4-2 Electrical fast transient/ burst ± 2 kV for power supply ± 2 kV for power lines supply lines IEC 61000-4-4 ± 1 kV for input/output ± 1 kV for input/ lines output Lines Surge ± 1 kV line(s) to line(s) ± 2 kV line(s) to earth ± 1 kV differential Mains power quality Mode should be that of a ± 2 kV common mode typical commercial or hospital environment. <5 % UT (>95 % dip in UT ) for 0.5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles <5 % UT (>95 % dip in UT) for 5s <5 % UT (>95 % dip in UT ) for 0.5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles <5 % UT (>95 % dip in UT) for 5s Mains power quality should be that of a typical commercial or hospital environment. If the user of RI Witness requires continued operation during power mains interruptions, it is recommended that RI Witness be powered from an uninterruptible power supply or a battery. 30A/M 30A/M Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. IEC 61000-4-5 Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 Note: UT is the a.c. mains voltage prior to application of the test level. Mains power quality should be that of a typical commercial or hospital environment. Section 3 Research Instruments Ltd Safety Warnings Guidance and Manufacturer’s Declaration — Electromagnetic Immunity IMMUNITY Test Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 IEC 60601 Test level 3 Vrms Compliance Electromagnetic environment level guidance 3 Vrms 150 kHz to 80 MHz 3 V/m 80 MHz to 2.5 GHz 3 V/m Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the Embryology Heated Plate, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result. Section 4 Product Overview Research Instruments Ltd SECTION 4 - PRODUCT OVERVIEW RI Witness is a system which operates within an assisted reproduction (AR) clinic setting and provides a method of identifying human samples throughout an AR cycle (from egg and sperm collection to embryo transfer). The system is intended to minimise the risks associated with traditional/manual double-checking and provides the essential controls necessary to ensure eggs, sperm and embryos are correctly matched and treated during the AR process. The RI Witness system comprises hardware, firmware and software components, which can be configured depending on the treatment activities, number of AR cycles conducted, size and layout of the AR clinic. RFID (radio frequency identification) technology provides the means of identifying the containers (dishes, tubes) in which eggs, sperm and embryos are transferred and stored. The containers are labelled by a clinician with a special RFID tag which has been assigned a unique identifier. The unique identifier is linked to a patient/couple (specific parentage). As samples are processed as part of an AR cycle, RFID readers (both heated and non-heated) read the tags on the container and their identity and status is confirmed on-screen. If containers containing samples of incompatible origin come into contact at any stage of this process, the system activates an alarm and prompts the clinician to respond. This manual is specifically for the Embryology Heated Plate (and associated Tube Reader accessory) in both its flush fitted and sit on top configuration. Other devices in the RI Witness range have their own manuals, as does the software. Embryology Heated Plate Figure 4-1 Sit on Top Heated Reader Figure 4-2 Tube Reader Accessory Section 4 Research Instruments Ltd Product Overview RI Witness Embryology Heated Plate Specification Table Part Description Temperature Sensor 5 x PT1000 (1 per Channel) Electrical heating is controlled by a built-in 5-channel PWM temperature controller: Temperature Control • Channel 1-4: Work surface surrounding the ITO glass window is divided into quarters • Channel 5: ITO glass window Temperature controller accuracy: better than ±0.2°C when calibrated against a known reference. Displayed resolution: 0.1°C Setpoint temperature range: 30-45°C Displays 3 x 7-segment LED display shows the temperature reading from the ITO glass window temperature sensor. Connectivity USB plug type A Input: 85-264VAC (100-240VAC Nominal), 47-63Hz, Power Supply <3A , Class I Output: 48VDC, Max 4.6A (220W) Operating Conditions Temperature: 15˚C (59˚F) to 40˚C (104˚F). Ambient temperature must be > 5°C below setpoint. Humidity: 15% to 85% RH (Non Condensing) RFID Specification Frequency: 13.56Mhz Power: 1W Width: 460mm Dimensions Depth: 220mm 6-70-807 Thickness: 20mm 6-70-807-A/-B Thickness: 34mm Mass 6-70-807: 3.0kg (plus Power Supply 1.0kg) 6-70-807-A/-B: 5.0kg (plus Power Supply 1.0kg) 10 Section 5 RI Witness™ Basic Operation Research Instruments Ltd SECTION 5 - RI WITNESS BASIC OPERATION Startup Procedure To turn the device on, plug the power cable from the device into the power supply in-line connector ensuring it is fully inserted. Then plug the power supply into the wall power outlet. Figure 5-1 Power Supply In-Line Connector Once the device is plugged in, it will display the current measured temperature on the display. The status LED will remain off until the temperature has stabilised at the specified setpoint. The time to reach this will vary according to the ambient temperature, but will generally be within 15-30 minutes. Once the temperature has stabilised, the green status light will illuminate (see “Alarms and System Status” on page 18 for more information). RI suggests that you keep the RI Witness computers and work areas (including the Embryology Heated Plate) switched on. This means that the heating and monitoring is constant. Shutdown Procedure To shutdown the device remove all electrical power by disconnecting the cable from the electrical outlet. Connecting to the Software Plug the device into the tablet or PC (or attached USB hub) using the USB A cable that protrudes from the device. Once the Windows operating system has recognised the devices within the Embryology Heated Plate, open the RI Witness WorkArea software. To verify that the RI Witness Work Area software can communicate successfully, navigate to the Work Area Status window (click the yellow triangle or press the (i) icon). This will bring up the Work Area Status window where the ‘Embryology Reader’ and ‘Temperature Control’ should be listed in the Connected Devices section with a green tick next to them. For more detailed set up information, refer to the RI Witness software manual (6-70-121UM). User Interface The Embryology Heated Plate contains a built in user interface which allows access to basic temperature setpoint and calibration adjustment. A complete set of calibration options can only be accessed through the RI Witness WorkArea software. Temperature Adjustment Indicator Light Up Button Status Indicator Light Down Button Audio Off Indicator Light 11 Temperature Display (shows ITO glass window temperature) Settings Button Figure 5-2 User Interface Section 5 Research Instruments Ltd RI Witness™ Basic Operation Operator Position The operator should be positioned in such a place to easily access the User Interface, work surface of the device and the connected touch screen (if used with the RI Witness WorkArea software). Achieving the Correct Sample Temperature The heated plate is divided into 5 areas for calibration purposes. In order to achieve the correct sample temperature place the sample on top of the heated areas shown below. Do not place samples on top of the User Interface. User Interface Blue area not temperature controlled Top Left Heated Area Bottom Left Heated Area Window Heated Area Top Right Heated Area Red denotes heated area Bottom Right Heated Area Figure 5-3 Embryology Heated Plate Heated Areas Ambient temperature must be >5°c from the set point for the temperature control to work effectively Place only plastic or glass ware on the window heated area. Temperatures within the Petri dish are adjusted by changing the setpoint temperature as described on the next page. The temperature inside a Petri dish will normally be slightly lower than the heated plate, depending on ambient conditions, type of Petri dish and the sample preparation. After the system has been installed in its operating location, the temperature of the heated plate should be adjusted to allow for this difference. We recommend using a thermometer calibrated to 37°C fitted with a small thermocouple probe, such as the RI IVF Thermometer to measure the temperature inside the Petri dish. Prepare a Petri dish that mimics your normal Petri dish preparation and place it on the heated surface in its normal position. Place the probe of the thermometer in the centre of the dish against the bottom of the dish and allow the temperature reading to stabilise. Adjust the setpoint temperature until the desired temperature in the dish is reached, allowing 20 minutes (or as long as required) in between each setpoint change to allow the Petri dish temperatures to stabilise. Figure 5-4 Thermometer Probe Positioned in a Petri Dish 12 Section 5 RI Witness™ Basic Operation Research Instruments Ltd Changing the Temperature Setpoint Using the Device The maximum setpoint temperature allowed for this device is 45°C. WARNING: In the event of sensor failure the plate may become hot (up to 65°C). The temperature setpoint is applied to all heating channels and is set using the following procedure, or from within the RI Witness WorkArea software. Refer to the RI Witness Software Manual (6-70-121UM) for further information. 1. Press and hold the Settings button for 3 seconds. 2. The Temperature Adjustment Indicator light will flash. The Temperature Display will now show the current setpoint (not the current temperature). 3. Adjust the value shown on the Temperature Display using the Up until the desired setpoint is shown. and Down 4. Save the temperature by pressing and holding the Settings button A beep will be heard. for 3 seconds. buttons 5. The Temperature Adjustment Indicator light will go out and the Temperature Display will now show the current temperature. Once the temperature has stabilised at the setpoint, the green Status Indicator Light will illuminate. Note: To exit the setpoint adjustment mode without saving changes, do not press any buttons for 15 seconds and the device will return to normal operation (the Temperature Adjustment Indicator light will go out). Changing the Temperature Setpoint Using a PC and RI Witness WorkArea Software To change the setpoint using the RI Witness WorkArea software, click on the temperature displayed at the bottom right hand side of the screen. This will bring up a pop up box with up and down arrows which can be used to adjust the setpoint temperature. The temperature controller will then begin controlling using the new settings . After adjusting the setpoint temperature, check sample temperature inside the Petri dish. 13 Section 5 Research Instruments Ltd RI Witness™ Basic Operation Temperature Calibration Note: Using the built-in user interface on the Embryology Heated Plate, it is only possible to calibrate the temperature of the ITO glass window. To perform a full calibration of all 5 heated areas, this must be done from within the RI Witness WorkArea software. Perform calibration only if the displayed temperature is different to the actual surface temperature of any of the 5 heated areas. The process of calibration allows the user to manually adjust the temperature so that the displayed temperatures match the temperature of the surface. Before temperature calibration can be performed the device must be in the same conditions that it will be in during normal operation. The temperature calibration is affected by ambient conditions. Place the probe of a calibrated thermometer in good thermal contact with the surface. Note: Simply touching the probe on the surface is not adequate. Use a purpose-made surface probe and use thermal transfer paste. Products sold for computer heatsinks are suitable, and RI can also supply suitable materials. Wait at least 30 minutes to allow the temperature to stabilise before calibrating. Heated areas are divided as shown below, with the ‘X’ denoting recommended thermocouple positions for calibration: User Interface Top Left Bottom Left Top Right Window Bottom Right Figure 5-5 Recommended Thermocouple Positions for Temperature Calibration ITO Glass Window Calibration Using Built-In User Interface During calibration using the built-in user interface close the RI Witness WorkArea software to prevent interference with the thermometer reading. 1. Position the thermocouple probe on the Window in the location shown above. 2. Press and hold the Settings and buttons simultaneously for 3 seconds. The Temperature Adjustment Indicator light will flash. The Temperature Display will now flash between the current temperature (which may be a changing value) and the letters C A L . 3. Adjust the value shown on the Temperature Display using the Up and Down until the temperature matches that shown on the external thermometer. 4. Save the calibration by pressing and holding the Settings button be heard. buttons for 3 seconds. A beep will 5. The Temperature Adjustment Indicator light will go out and the Temperature Display will now show the current temperature with applied calibration. Leave the probe in position and once the temperature has stabilised at the setpoint, check that the calibration is accurate. Repeat the calibration process if necessary. The green Status Indicator Light will illuminate once temperatures have stabilised. 14 Section 5 RI Witness™ Basic Operation Research Instruments Ltd 6. After adjusting calibration check sample temperatures and adjust the setpoint temperature if required. Note: To exit the window calibration mode without saving changes, do not press any buttons for 15 seconds and the device will return to normal operation. The Temperature Adjustment Indicator light will go out and the Temperature Display will stop flashing. Full 5-channel Calibration Using PC and RI Witness WorkArea Software Full calibration of the 5 heated areas requires that each of the areas is calibrated in turn. 1. Open the RI Witness WorkArea software and navigate to the WorkArea Status window. 2. Click on the yellow triangle or the (i) icon then click WorkArea Settings, then Connected Devices, then Temperature Controller, then Check Calibration. The screen will now show the current temperature and calibration offsets of the five different heated areas. Note: RF will be switched off automiatically when on the Temperature Control screen. 3. Each heated area is independent so the order of calibration is not important. Position the thermocouple probe in one of the positions shown above. 4. Allow the reading to stabilise, then compare the temperature shown in the WorkArea software with the thermometer reading. 5. A difference within ± 0.2°C is acceptable. If the readings are outside this increase the offset to increase the reading displayed by the software, or decrease the offset to decrease the reading displayed by the software to match the temperature displayed by the thermometer. Allow a small delay for the offset change to register. When changing the offset, the temperature controller will then begin controlling using the new settings, so the surface temperature of that heated area may take a short time to re-stabilise. 6. Repeat this process for all 5 heated areas. 7. Once calibration is complete it is advisable to verify the temperature of each heated area to check that temperature calibration has been carried out effectively. After adjusting calibration, check sample temperatures and adjust the setpoint temperature if required. 15 Section 5 Research Instruments Ltd RI Witness™ Basic Operation Tube Reader Antenna Accessory The Tube Reader Antenna is an accessory for the Embryology Heated Plate that allows tags to be read in a vertical orientation. It is specifically designed to read tags placed on tubes in the RI Tube Holder. The Tube Reader Antenna is a passive device that only becomes powered when attached to the Embryology Heated Plate. The correct mounting orientation position is shown below in Figure 5-6. Tube Reader Antenna Connections Figure 5-6 Tube Reader Connections on the Embryology Heated Plate Refer to “Section 7- Care and Maintenance” on page 23 for cleaning precautions relating to the Tube Reader Antenna. Tube Reader Antenna Figure 5-7 Tube Reader Correctly Mounted on the Embryology Heated Plate 16 Section 6 Troubleshooting Research Instruments Ltd SECTION 6 - TROUBLESHOOTING RFID SYSTEM Problem Possible Cause Metal near reader Solution Remove any metallic objects from the area, check if the tags come back into Work Area Check security of USB and power cable Loose or no connection connections. Verify that the light on the power supply is illuminated Tags Not Reading Other electrical devices in the lab can cause RF noise/interference. If a portable electronic device RF noise or interference has been brought close to the device, remove it and check if the tags come back into the Work Area Broken tag Check whether the tag is readable by a different RI Witness device. If it is not, discard that tag Antenna tuning problem Navigate to the Work Area Settings screen, then click Connected Devices, then Embryology Reader, then RFID Tuning, check that all 5 channels (or 3 if you do not have the tube reader accessory connected) have green ticks next to them. If any have a yellow warning triangle next to them, contact an RI service representative 17 Section 6 Research Instruments Ltd Troubleshooting Temperature Control: Alarms and System Status The status of the temperature control system is shown by the Status Indicator Light positioned on the user interface of the device. Status Indicator Light Colour Off Meaning / Priority Please wait Initial power up/setpoint/mode/calibration changed. The light will be off until temperature of all heating systems has stabilised. Green (constantly on) Ready for use Temperature of all heating systems has stabilised. Yellow (constantly on) Low Priority Alarm Built-in user interface and RI Witness WorkArea software will show current window temperature. Press the button to cycle through the Alarm Condition Codes. Refer to tables on the following pages for details of each code. If the alarm sounds, finish the current procedure and investigate the cause of the alarm. Yellow (flashing) Medium Priority Alarm Built-in user interface and RI Witness WorkArea software will show current window temperature. Press the button to cycle through the Alarm Condition Codes. Refer to the tables on the following pages for details of each code. If the alarm sounds, finish the current procedure and investigate the cause of the alarm. When multiple alarms are active, the highest priority alarm will be shown or the icon in the RI Witness WorkArea Software, and on the device the Status Indicator Light. Note: For a full list of possible faults relating to each alarm condition and applicability of each alarm condition, refer to the tables on the following pages. Alarm Condition Codes are only displayed whilst the alarm is active and are cleared when the alarm is no longer active. Audible Alarms Audible alarms are sounded to indicate Low and Medium Priority Alarms, as described above. When in alarm condition it is possible to turn the Audio Off by pressing the down button. The Audio Off Indicator Light will illuminate for the duration of the alarm condition. The Audio will return if another alarm is activated or if the button is pressed again. Press the Up button whilst alarms are active to cycle through the error codes. See pages 19 to 22 for full list of Alarm Condition Codes. When multiple alarms are active, the audio for the highest priority alarm will be sounded. The alarm volume is not adjustable. Audible range for alarm system is as follows. Priority Medium Priority Low Priority Range 44.4 - 55.5dB 41.5 - 55.5dB Average 53dB 51.5dB 18 Section 6 Troubleshooting Research Instruments Ltd Alarm System Testing In order to test functionality of the alarm system hold down the button for 3 seconds when there are no active alarms. This will trigger a medium priority alarm signal, (3 audible pulses and 3 yellow flashes of the status indicator light). This check should be performed at regular intervals to reduce the chance of missing an alarm due to failed loudspeaker or status indicator light. Alarm Conditions Codes Alarm Code E01 Fault Condition ITO Window Heating Failure E02 Bottom Right Heating Channel Failure Bottom Left Heating Channel Failure Top Right Heating Channel Failure Top Left Heating Channel Failure Failure Channel ITO Window Sensor Failure Bottom Right Sensor Failure Bottom Left Sensor Failure Top Right Sensor Failure Top Left Sensor Failure E03 E04 E05 E06 E07 E08 E09 E10 19 Priority Low Low/ Medium Fault Description Alarm Actions Heating system is not Heating able to heat the specified controller heating channel. Alarm power is set will be activated 2 to 0% for minutes after power that heating on if there is less than channel until 1.5˚C temperature rise device is between 1 and 2 minutes restarted. after power on. If the temperature at 1 minute is already within ± 2.5˚C from the setpoint the test is omitted. No signal/out of range signal from temperature sensor. Alarm activates at any time if the sensor Low priority circuit fails to read a valid alarm is temperature. activated if the fault occurs when system is switched on. After this time a medium priority alarm is activated Heating power is set to 0% for that heating channel until a valid temperature is read. If any of the ITO Window sensors fail the temperature display will show --.-˚C Solution Restart the device by removing mains power then re-connecting. Possible sensor, cable or controller fault. May also be caused when the device is in over temperature condition. Restart the device by removing the mains power, then reconnect. Contact your distributor or RI Service if fault persists. Section 6 Research Instruments Ltd Alarm Code E11 E12 E13 E14 E15 E16 E17 E18 E19 E20 Fault Condition ITO Window Heating Channel Over Temperature Bottom Right Heating Channel Over Temperature Bottom Left Heating Channel Over Temperature Top Right Heating Channel Over Temperature Top Left Heating Channel Over Temperature ITO Window Heating Channel Temperature outside ± 1°C Bottom Right Heating Channel Temperature outside ± 1°C Bottom Left Heating Channel Temperature outside ± 1°C Top Right Heating Channel Temperature outside ± 1°C Top Left Heating Channel Temperature outside ± 1°C Troubleshooting Priority Fault Description Low / Medium Heating channel has exceeded the maximum allowable setpoint If fault temperature. Alarm occurs when activated at any time if the system the temperature sensor is switched exceeds 50˚C. on Medium Heating channel has deviated by more than 1˚C from the setpoint temperature. Alarm enabled 10 minutes after the temperature reaches ±2.5˚C from the setpoint temperature. Alarm Actions Temperature controller power is set to 0% until temperature falls to below 50˚C. Solution Possible heater or controller fault. Note: If the temperature continues to rise past this point, over temperature protection built in to the device will shut down the heating. The temperature controller continues to operate to bring back within the allowable limits. This may be caused by placing either hot or cold objects on the device, in particular the ITO Window. In this case either remove the object or wait a short time for the setpoint temperature to be reached. Sudden air movements or temperature change can also cause minor temperature fluctuations. In this case wait a short while for the temperature controller to respond. 20 Section 6 Troubleshooting Alarm Code E21 E22 E23 E24 E25 Fault Priority Condition ITO Window Medium Heating Channel Temperature outside ± 2.5°C Bottom Right Heating Channel Temperature outside ± 2.5°C Bottom Left Heating Channel Temperature outside ± 2.5°C Top Right Heating Channel Temperature outside ± 2.5°C Top Left Heating Channel Temperature outside ± 2.5°C Research Instruments Ltd Fault Description Heating channel has deviated by more than 2.5˚C from the setpoint temperature. Alarm enabled once it has reached ±2.5˚C from the setpoint temperature and is more than 1 minute after power on. Alarm Actions The temperature controller continues to operate to bring back within the allowable limits. Solution This may be caused by placing either hot or cold objects on the device, in particular the ITO Window. In this case either remove the object or wait a short time for the setpoint temperature to be reached. Sudden air movements or temperature change can also cause minor temperature fluctuations. In this case wait a short while for the temperature controller to respond. May also be caused when the device is in over temperature condition. Restart the device by removing the mains power, then reconnect. Contact your distributor or RI Service if fault persists. 21 Section 6 Research Instruments Ltd Alarm Code E26 E27 E28 E29 E30 E31 Troubleshooting Fault Priority Condition ITO Window Medium Heating Channel Low Heating Rate Bottom Right Heating Channel Low Heating Rate Bottom Left Heating Channel Low Heating Rate Top Right Heating Channel Low Heating Rate Top Left Heating Channel Low Heating Rate Fault Description Memory Fault Memory/controller fault. System failed to read or write data correctly. If it happens during run time the system will carry on with current data. If it happens during start up the system will load the default values and needs reconfiguration of setpoint calibration. Low Alarm Actions Heating controller Temperature did not achieve a controller temperature within 2.5˚C continues to of the setpoint in 15 operate. minutes from power on. System continues to operate until power is removed. When power is returned the system will operate with the default calibration and setpoint values. Solution If the device is operated in an environment where the ambient temperature is colder than the specified operating conditions or if there is a large amount of cold airflow over the device, then this alarm may triggered routinely. If neither of these conditions are present, restart the device. If the fault reoccurs contact an RI Service personnel. Set the setpoint temperature then re-calibrate. If the problem persists then there may be a fault with the controller. If the problem is resolved then the memory may have been corrupted during saving of values, eg if the device loses power whilst saving values. 22 Section 7 Care and Maintenance Research Instruments Ltd SECTION 7- CARE AND MAINTENANCE Cleaning RI Witness Embryology Heated Plate and Tube Reader Antenna may be cleaned with a soft cloth and mild detergent. Do not disconnect the cables attached to the device. If the Tube Reader Antenna is removed for cleaning be mindful to allow the contact surfaces on both the Heated Plate and the Tube Reader Antenna to fully dry before reattaching to ensure cleaning products are not trapped in the interface. Do not use solvents for cleaning. Do not disconnect readers. 23 Research Instruments Ltd Section 8 Repairs and Returns SECTION 8 - REPAIRS AND RETURNS Reuse Statement Assuming RI Witness is regularly maintained and routinely serviced, it should perform as required for a minimum of 7 years continual use, after which time we recommend you consider its replacement. Should you notice impaired performance and/or any issues where safety is compromised, or have any other concerns during the use of RI Witness, seek the advice of RI or their authorised representative promptly. RI Repairs System In the event that you have a problem with a RI instrument, please follow the procedure below to ensure prompt attention. 1. Read the ‘Troubleshooting’ section. 2. If you require any further help contact your distributor or RI directly. RI will try to resolve the problem as quickly as possible. Product Disposal (European Union) If the product is no longer serviceable it must be sent back to RI to be destroyed in an environmentally safe way. Do not dispose of this device with ‘normal’ waste. RI Returns System 1. Contact RI to obtain a Returned Materials Authorisation (RMA) number. Note: Goods will not bereplaced or refunded without prior agreement and clearly stating the RMA number. 2. Pack the item carefully in its original packaging. RI will not accept responsibility for damage due to incorrect packaging. Replacement items or additional repairs will be invoiced. 3. Clearly label the package with the RMA number, mark the package “Urgent - Returned Items For Repair”, and ship to the address on the next page. Goods should be insured for their full value during shipping. Contact Details Research Instruments Ltd, Bickland Industrial Park, Falmouth, Cornwall, TR11 4TA, UK Tel: +44 (0) 1326 372 753 Fax: +44 (0) 1326 378 783 E-mail: service@research-instruments.com Website: www.research-instruments.com Obligation to Inform In compliance with the European Medical Device Directive 93/42/EEC as amended, it is your duty to inform RI if you believe this device has, or may have, caused or contributed to the death of a patient or user or to a serious deterioration in their state of health. Feedback Thank you for purchasing a RI product. To help RI develop the best tools for ART, we rely on customer feedback. If you have any suggestions for how we can improve our products or the information we provide with them, please send them to feedback@research-instruments.com. Your feedback will help us develop the product and supporting materials to meet your future needs. Thank you. 24
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-GB Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c143 79.161210, 2017/08/11-10:28:36 Create Date : 2017:12:01 12:22:17Z Metadata Date : 2017:12:01 12:22:26Z Modify Date : 2017:12:01 12:22:26Z Creator Tool : Adobe InDesign CC 13.0 (Windows) Instance ID : uuid:1cc689d3-ce6d-47e7-ad9d-42cadf49f991 Original Document ID : xmp.did:222ABD753592E311BF37A4FDECD85711 Document ID : xmp.id:b65207ac-4ff5-0b4c-97b8-92b6084ccf2a Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:7a3fbc1e-799a-5d44-abcc-093bd15b362e Derived From Document ID : xmp.did:8c93196f-dcbd-394a-8fb1-f075bc7717b5 Derived From Original Document ID: xmp.did:222ABD753592E311BF37A4FDECD85711 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 13.0 (Windows) History Changed : / History When : 2017:12:01 12:22:17Z Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 28 Creator : Adobe InDesign CC 13.0 (Windows)EXIF Metadata provided by EXIF.tools