INSTALLATION INSTRUCTIONS
WIRELESS UNIVERSAL
STRIKE INTERFACE
(WUSI)
3820 Stern Avenue
St. Charles, IL 60174
Phone: 630-762-4450
Fax: 630-762-4455
P/N: M053-xxx-x001
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 2 of 17
INSTALLATION INSTRUCTIONS
Wireless Universal Strike Interface (WUSI)
NOTE: These instructions are for installing the Wireless Universal Strike Interface (WUSI), a component of a
Wyreless Access System. After completing this installation refer to the “Configuring and Operating the Wyreless
Access System” manual.
Table of Contents
1. Wyreless AccessTM System Components........................................................................................................3
1.1 Overview .......................................................................................................................................................3
1.2 Wireless Universal Strike Interface (WUSI) Components & Sales Models ..................................................4
2. Installing the WUSI .........................................................................................................................................4
2.1 Tools – Hardware Required...........................................................................................................................4
2.2 Determining the Best WPIM and WUSI Locations.......................................................................................5
2.3 Mounting the WUSI ......................................................................................................................................6
2.4 Getting Wires In & Out of the WUSI ............................................................................................................7
2.5 Wiring the WUSI to its Access Control Peripherals......................................................................................8
3. WUSI Cable/Wire Specifications .................................................................................................................14
4. Contacting Recognition Source ....................................................................................................................15
5. FCC Compliance & Warnings......................................................................................................................16
5.1 FCC Compliance .........................................................................................................................................16
5.2 UL Compliance............................................................................................................................................16
5.3 Warnings......................................................................................................................................................16
6. Revision History.............................................................................................................................................17
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 3 of 17
1. Wyreless AccessTM System Components
1.1 Overview
Every access control system that uses Wyreless AccessTM contains two different types of modules (Figure
1-1):
• at least one Wyreless Panel Interface Module (WPIM), and
• at least one Wyreless Access Point Module (WAPM)
Figure 1-1 – Wyreless Access System Block Diagram
Recognition Source’s product line contains several different expressions of each module.
The WPIM is wired to the access control panel and ideally is installed very close to the access control
panel. The WPIMs installation location is determined by the location of the WAPMs with which it will
communicate using RF.
The WAPM is installed at the access point where access will be controlled and/or monitored. Depending
on the application and which WAPM is used, some wiring at the access control point may be required.
Regardless of which WPIM or WAPM module is used, the communication link between the WPIM and
WAPM is always RF.
This manual describes the installation of a Wireless Universal Strike Interface (WUSI) which is a
WAPM.
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 4 of 17
1.2 Wireless Universal Strike Interface (WUSI) Components & Sales
Models
The WUSI (Figure 1-2 & Figure 1-3) includes the following components:
• a reader/keypad connector
• strike relay connector
• door position input
• request to exit input
• request to enter input
• tamper input & tamper switch
• flash programming port
• RF Transceiver
Figure 1-2 – Front of the WUSI
Figure 1-3 – Inside the WUSI
MODEL MOUNTING LOCATION
WUSI surface indoor
Table 1-1- WUSI Sales Model Table
2. Installing the WUSI
2.1 Tools – Hardware Required
• Hammer
• 9/32” & 3/4” drill bits (the size will depend on the mounting fasteners used)
• Flat and Phillips head screwdrivers (1/8” wide flat blade for screw terminals)
• Pencil
• Mounting Kit (K381-000-001), provided, including four zinc, pan head Phillips, 8-18 X 1 ½” sheet
metal screws and four heavy-duty anchors
• Mounting Kit (K384-003-001), provided, including four #8 X 2 ½” screws and four 1” round by 1”
high (1” O.D. x 1”) spacers
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 5 of 17
2.2 Determining the Best WPIM and WUSI Locations
Proper selection of WPIM and WUSI module mounting locations insures reliable RF communications.
The WPIM manual contains a section for determining the best location for the WPIM.
The maximum distance between WPIM and a WUSI is 200’ horizontally when installed inside a building
on the same floor that uses normal building construction materials. Never locate the WUSI and WPIM
more than one (1) floor apart. If on different floors, limit the maximum horizontal distance to 100’. The
maximum distance is 1000’ for a line of sight installation.
The maximum distance between WPIM and a WUSI is 200’ horizontally when installed inside a building
that uses normal building construction materials. The maximum distance is 1000’ for a line of sight
installation.
This section provides additional application specific help and guidelines to select the best mounting
location for the WUSI Transceiver Control Box:
• Mount the WUSI Transceiver Control Box inside the protected area.
• Mount the WUSI Transceiver Control Box on the wall, at least 55” from the floor
• Mount the WUSI Transceiver Control Box within 500’ cable feet of the Card Reader or other input
device
• Mount the WUSI Transceiver Control Box within 500’ cable feet of the Strike.
• A WUSI must, in all directions (sides, top, bottom, and back), have a minimum 1” separation from
any metal surface. Therefore if the WUSI must be mounted on a metal surface, though not
recommended, the supplied 1” spacer kit (K384-003-001) must be used.
NOTE: A WUSI located with a substantial steel barrier intervening between it and the WPIM may
require alternate WUSI and/or WPIM placement in order to ensure reliable RF communications.
In these applications, mount the WPIM remote from the access control panel. Choose the WPIM or
the WPIM’s Remote Antenna location to prevent “shadowing” of the WUSI from WPIM radio
transmissions.
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 6 of 17
2.3 Mounting the WUSI
2.3.1 TRANSCEIVER CONTROL BOX – A 1” hole is provided in the back of the Transceiver Control
Box for routing wires in & out. If needed, additional hole(s) can be drilled in the lower left hand
corner of the Transceiver Control Box. Wire routing inside the enclosure is very important. Improper
wire routing will reduce the RF range. Keep the wires inside the enclosure as short as possible (i.e. do
not coil any excess wire inside the enclosure) (Figure 2-1 & Figure 2-2).
Figure 2-1 – Improper Wire Routing
Figure 2-2 – Proper Wire Routing
2.3.1.1 Remove the Transceiver Control Box cover.
2.3.1.2 Place the Transceiver Control Box (cover removed) against the wall in the position it was
successfully “link” tested.
2.3.1.3 Using Transceiver Control Box as a template, mark the four corner mounting holes and the ½”
wire hole (if used) with a pencil.
2.3.1.4 Drill a 9/32” hole at each mounting mark, 1 ¾” deep, and a ½” hole at the wire hole mark (if
used).
2.3.1.5 Insert the four anchors provided firmly into the holes so they are flush with the wall.
2.3.1.6 Depending on the installation, you may want to screw the Transceiver Control Box to the wall
now or wait until the rest of the components are installed to facilitate wire routing.
If the WUSI is to be mounted on a non-metallic surface use the #8, 1½” screws provided (kit:
K381-000-001) to attach the WUSI to the wall..
If the WUSI is to be mounted on a metallic surface use the round 1” high spacers and the #8,
2½” screws provided (kit: K384-003-001) to attach the WUSI 1” from the wall.
2.3.2 CARD READER – If the installation uses a card reader or other input device, mount it using the
manufacturer’s installation instructions. Route the card reader wires into the Transceiver Control Box.
2.3.3 STRIKE - If the installation uses a strike device, mount it using the manufacturer’s installation
instructions. Route the strike device wires into the Transceiver Control Box.
2.3.4 DOOR POSITION SWITCH – If the installation uses a door position switch, mount it using the
manufacturer’s installation instructions. Route the door position switch wires into the Transceiver
Control Box.
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 7 of 17
2.3.5 REQUEST TO EXIT DEVICE – If the installation uses a separate request to exit device, mount it
using the manufacturer’s installation instructions. Route the request to exit device wires into the
Transceiver Control Box.
2.3.6 REQUEST TO ENTER DEVICE – If the installation uses a request to enter device, mount it using
the manufacturer’s installation instructions. Route the request to enter device wires into the
Transceiver Control Box.
2.4 Getting Wires In & Out of the WUSI
The back of the WUSI enclosure has a pre-drilled hole for getting wires in & out of the WUSI. For
optimum WUSI performance, this wire hole must be used.
If holes must be drilled in the WUSI enclosure determine the size and number of entry/exit connectors to
be used.
Use entry/exit wiring connectors/glands that are compliant with local electrical codes (i.e. conduit, etc.)
NOTE: When drilling, make certain that the drill bit does not damage any electronics inside the
enclosure. Use light drill pressure so that the bit does not enter the enclosure very far when the bit
breaks through the inside of the enclosure.
Figure 2-3 – Rear of WUSI Enclosure
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 8 of 17
2.5 Wiring the WUSI to its Access Control Peripherals
There are seven WUSI PCB connectors that provide connections to Access Control Peripherals that the
WUSI will monitor and/or control (Figure 2-4):
• DC Input Power
• Tamper Input
• Door Position Input
• Request to Exit Input
• Request to Enter Input
• Portal Output
• Card Reader
Some of the connections are optional based on the specific application of the WUSI. Refer to Section 3
for cable and wire specifications for the WUSI.
Figure 2-4 – WUSI Printed Circuit Board (PCB) Connections
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 9 of 17
Figure 2-5 – Typical Access Point Configuration
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 10 of 17
2.5.1 DC Input Power
The DC Input Power connection is mandatory. An external, UL approved, DC power supply that can
supply typically 12 VDC (7-14VDC range) must be provided. The DC power supply must be capable
of providing 300 mA of current to power the WUSI. Add the power requirements of the access
control peripherals connected to the WUSI to the 300 mA to determine the overall size of the DC
power supply.
Figure 2-4 shows where the DC power is connected to the WUSI PCB. Table 2-1 shows how to
connect the DC power. Make certain to observe the polarity.
Connect the shield of the DC Input Power cable to the Ground (-) terminal at the power supply. Do
not connect the cable shield at the WUSI (Figure 2-5).
12VDC+
DC
INPUT
POWER GND
The WSUI typically operates from 12 VDC and draws 300mA
peak maximum. This does not include the power consumption
required by the peripherals (strike, reader, etc).
Table 2-1 – DC Input Power Connections
2.5.2 Tamper Input
The Tamper Input connection is optional and provides a way of monitoring and external tamper
switch. The Tamper Input is in parallel with the Tamper Switch, SW1, on the WUSI PCB. SW1
monitors the state of the WUSI enclosure door and generates a tamper trouble when the door is open.
If other possible tamper conditions (i.e. power supply enclosures, gate controllers, etc.) need to be
monitored, wire a single pole, single throw (SPST) to the Tamper Input. When terminals
TAMPER_NC & GND (Figure 2-4) are shorted, a tamper trouble signal is generated (Table 2-2).
Connect the shield of the Tamper Input cable to the WUSI GND). Do not connect the cable shield at
the Tamper Switch (Figure 2-5).
The Tamper Input connection is not connected in UL installations.
TAMPER_NC
TAMPER GND
A dry contact closure across these terminals causes a tamper
trouble signal to be sent to the ACP
Table 2-2 – Tamper Input Connections
2.5.3 Portal Inputs
The portal inputs consist of a Request to Enter, Request to Exit, and Door Position Switch inputs.
Wiring any or all of the Portal Inputs is optional based on the WUSI application. All three inputs are
expecting an open circuit or a short circuit across their terminals.
When terminals R_ENTER & GND (Figure 2-4) are shorted, a “Request to Enter” signal is generated
(Table 2-3).
When terminals R_EXIT & GND (Figure 2-4) are shorted, a “Request to Exit” signal is generated
(Table 2-3).
When terminals DPS & GND (Figure 2-4) are shorted, a “Portal Closed” signal is generated. When
terminals DPS & GND are open, a “Portal Open” signal is generated (Table 2-3).
Connect the shield of the Portal Input cables to the appropriate WUSI GND terminal.. Do not connect
the cable shield at the Request to Enter, Request to Exit, or Door Position Switches (Figure 2-5).
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 11 of 17
R_ENTER
REQUEST
TO
ENTER GND
A dry contact closure across these terminals initiates a request
to enter.
R_EXIT
REQUEST
TO
EXIT GND
A dry contact closure across these terminals initiates a request
to exit.
DPS
DOOR
POSITION
SWITCH GND
A dry contact closure across these terminals indicates to the
ACP that the access point portal is closed. An open circuit
indicates to the ACP that the access point portal is open.
Table 2-3 – Portal Inputs Connections
2.5.4 Portal Output
The Portal Output consists of a Strike Relay with form C outputs (common, normally open, and
normally closed). Wiring of the Portal Output is optional based on the WUSI application.
When the portal is unlocked, the Strike Relay Output turns on indicating that the portal should be
unlocked. Therefore the appropriate side of the relay contact (normally open or normally closed)
must be used to make certain that when the relay is de-energized that the portal is locked and when
the relay is energized that the portal is unlocked.
STR_NC
STR_C
STRIKE
RELAY
OUTPUT STR_NO
Strike output, isolated form C contact rated 30VAC/VDC, 5A
(silver alloy contacts for heavy loads).
Table 2-4 – Portal Output Connection
A Suppressor must be installed with every electrical switching device run through the Portal Output
relay contact. The Suppressor protects the WUSI from the power generated by the collapsing
magnetic field of an electrical load. The Suppressor will maximize the life of the WUSI.
Follow the Electrical Lock/Load manufacturer’s recommendation for suppression of
magnetic/inductive loads. A properly rated bi-directional Tranzorb (Silicon Avalanche Diode) may
also be used. Install the Suppressor within 18 inches of the electrical load (Figure 2-6).
NOTE: The Portal Output must utilize a dedicated shielded cable to prevent transient contamination
of other WUSI signal wiring. Do not run the Portal Output wires in the same cable or conduit as any
other WUSI wiring. The Portal Output wiring should be at least 12 inches away from any other
WUSI wiring or it should be run in a separate conduit.
Connect the shield of the Portal Output cables to the appropriate WUSI J7-6 terminal (GND). Do not
connect the cable shield at the Electrical Lock/Load (Figure 2-5).
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 12 of 17
Figure 2-6 – Portal Output Suppression Diagram
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 13 of 17
2.5.5 Card Reader/Keypad
Any input device with a Wiegand or Clock & Data bit stream can be used with the WUSI. A
transaction must be a single bit stream of between 8 and 255 bits. Devices which output individual
characters/digits are not acceptable.
The WUSI provides a Card Reader interface. Wiring of the Card Reader is optional based on the
WUSI application.
Take the power requirements of the Card Reader into consideration when sizing the power supply for
the WUSI and its peripherals (Section 2.5.1).
Card Reader connections are shown in Table 2-5.
Connect the Card Reader cable shield to the WUSI GND terminal on the Card Reader connector. Do
not connect the cable shield at the Card Reader (Figure 2-5).
CLK/D1
DATA/D0
Card Reader inputs, each input line has a 3.3k pull up resistor
to 5V, and a 12V transient suppressor to GND.
12VDC+
GND
Reader power supply output. The WUSI PC board routes its
own power supply input to these terminals, so the readers see
the same supply as the WUSI. If other than 12 VDC is required
for the input device, then a separate input device power supply
must be used. Make certain that a common ground connection
is established between the input device’s power supply and the
WUSI.
GRN_LED
Green LED signal line. This signal goes to ground through
100ohm when activated. When deactivated, it is pulled up to
+5V through 1.1kohm.
CARD
READER
RED_LED Red LED signal line. Same functionality as GRN line, except
RED.
Table 2-5 – Card Reader Connections
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 14 of 17
3. WUSI Cable/Wire Specifications
Application Part Number AWG Description Maximum
Distance
DC Power
Input Belden 8760 18 2 conductor 1,000’
Tamper Belden 8760 18 twisted pair
shielded 2,000’
Request to
Enter Belden 8760 18 twisted pair
shielded 2,000’
Request to
Exit Belden 8760 18 twisted pair
shielded 2,000’
Door Position
Switch Belden 8760 18 twisted pair
shielded 2,000’
Strike
Relay Output Belden 8760 18 twisted pair
shielded 2,000’
Card
Reader Alpha 1296C 22 6 conductor
shielded 500’
Table 3-1 – WUSI Cable/Wire Specifications
This completes the installation of the WUSI.
If the Wyreless Panel Interface Module (WPIM) that will control this WUSI is not
installed, now is the time to install it, please refer to the “PIM Installation Instruction”
manual.
If the WPIM is installed, then you are ready to configure your Wyreless Access System,
please refer to the “Configuring & Operating a Wyreless Access System” manual.
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 15 of 17
4. Contacting Recognition Source
For questions regarding Wyreless Access™:
(630) 762-4450
(630) 762-4444 fax
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 16 of 17
5. FCC Compliance & Warnings
5.1 FCC Compliance
• This device has been authorized by the FCC Rules and Industry Canada.
• This device complies with the limits for a Class B digital device and a Class B intentional radiator,
pursuant to Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to
the following two conditions: (1) This device may cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
• The Wyreless Access System Component must be installed by qualified professionals or contractors
in accordance with FCC part 15.203, Antenna Requirements.
• Do not use any antenna other than the one provided with the unit.
5.2 UL Compliance
• The Wireless Universal Strike Interface (WUSI) listing under UL294 as an access control system
accessory is pending.
• Access equipment manufactured and/or sold by Recognition Source, LLC, is not rated for, or
intended for use in life safety installations.
• UL listed panic hardware shall be used to allow emergency exit from the protected area.
• UL listed compatible readers: HID, Model PROXPOINT.
• Use Recognition Source Power Supply, model PS-12VDCR-500mA UL listed class 2 power supply.
5.3 Warnings
• RF Exposure - To comply with FCC RF exposure requirements for mobile transmitting devices this
transmitter should only be used or installed at locations where there is normally at least a 20 cm
separation between the antenna and all persons.
• Do not co-locate and operate in conjunction with any other antenna or transmitter.
• Changes or modifications not expressly approved by Recognition Source could void the user’s
authority to operate the equipment.
3820 Stern Avenue
St. Charles, IL 60174
(630) 762-4450
P/N: M053-xxx-x001 (630) 762-4444 fax Page 17 of 17
6. Revision History
Version Date Changes
x001 11/26/03 preliminary in house release for comments