If ODU is not connected in the right order, related devices may fail to communicate with
each other or the unit may read wrong information. Given this, you need to connect the unit with
accurate RF Port and Signal Port in a corresponding number.
For unused RF Ports for ODU expansion, make sure to terminate them using SMA Term.
When you put ODU on the top of BIU, it is recommended to install the unit at least 1U
apart from BIU. Heat from BIU climbes up to reach ODU.
5.1.6
Consumption Power of BIU
The table below shows power consumption of BIU:
Part
Unit
Consumption Power
Remark
Shelf
Common Part
MCDU
7.5 W
MCPU
MPSU
MDBU 800PS
12W
MDBU 800PS+900I+Paging
20W
MDBU 850C
12W
MDBU 850C+700PS
19W
MDBU 1900P
20W
MDBU AWS-1
12W
MDBU
BIU supplies power for ODU. Therefore, when you want to calculate total power consumption of
BIU, you need to add power consumption of ODU to the total value.
Power consumption of ODU is given in the later paragraph describing ODU.
Confidential & Proprietary
63/99
5.2 ODU Installation
ODU should be, in any case, put on the top of BIU. This unit gets required power and RF
signals from BIU. The following table shows components of ODU:
No.
Unit
Common Part
Optional Part
5.2.1
Description
Remark
Shelf
Including Main Board, 19”,1U
1EA
RF Cable
SMA(F) to SMA(F), 400mm
2EA
Signal Cable
2Row(15P_F) to 2Row(15P_M),650mm
1EA
DOU
Optical Module with 4 Optic Port
Up to 2EA to be
inserted
ODU Shelf Installation
ODU is a shelf in around 1U size. Its width is 19” and so this unit should be inserted into a 19”
Standard Rack. ODU should be, in any case, put on the top of BIU. BIU should be distant
around 1U when the unit is installed.
5.2.2
ODU Power Cabling
ODU does not operate independently. The unit should get power from BIU.
When you connect 2-column, 15-pin D-SUB Signal cable from BIU and install DOU, LED on the
front panel is lit. Through this LED, you can check state values of LD and PD of DOU.
5.2.3
ODU Optic Cabling
As optical module shelf, ODU makes electronic-optical conversion of TX signals and then
makes optical-electronic conversion of RX signals. ODU can be equipped with up to two DOUs.
One DOU supports four optical ports and one optical port can be connected with ROU.
Optionally, only optical port 4 can be connected with OEU.
As WDM is installed in DOU, the unit can concurrently send and receive two pieces of
wavelength (TX:1310nm, RX:1550nm) through one optical core. DOU has SC/APC of optical
adaptor type.
Confidential & Proprietary
64/99
Figure 5.4 – Optical cable of SC/ACP Type
For optical adaptor, SC/APC type should be used. To prevent the optical access part from being
marred with dirt, it should be covered with a cap during move. When devices are connected
through optical cables, you need to clear them using alcohocol to remove dirt.
5.2.4
Insert DOU to ODU
In an ODU Shelf, up to two DOUs can be installed. DOU module is in Plug in Play type.
When you insert DOU in ODU, insert the unit into the left DOU1 slot first. You can be careful as
the number is silk printed at the left.
The following figure shows installation diagram of ODU with one DOU inserted in it.
The following figure shows installation diagram of ODU with two DOUs inserted in it.
When you insert DOU into ODU, insert the unit into the left DOU1 slot first. Into unused
slot, you need to insert BLANK UNIT in any case.
Confidential & Proprietary
65/99
5.2.5
Consumption Power of ODU
ODU gets power from BIU. One ODU can be equipped with up to two DOUs. Depending on
how many DOUs are installed, power consumption varies. The table below shows power
consumption of ODU:
Part
Unit
Consumption Power
ODU_4
DOU 1 EA
13W
ODU_8
DOU 2 EA
26W
Remark
5.3 ROU Installation
5.3.1
ROU Enclosure installation
ROU is designed to be water- and dirt-proof. The unit has the structure of One-Body enclosure.
It satisfies water-proof and quake-proof standards equivalent of NEMA4.
ROU can be mounted into either of a 19” Standard Rack or on a Wall.
Basically, ROU has both of a Wall Mount Bracket and a Rack Mount Bracket.
Depending on the use of the Rack Mount Bracket, the bracket can be removed.
The following shows dimension of the fixing point for the Wall Mount Bracket.
Figure 5.5 – How to install ROU
Confidential & Proprietary
66/99
Figure 5.6 – Dimension used to install ROU on the WALL
ROU Wall Mount Installation
Turn M12 Fixing Screws by half on the wall and fully fix the screw with a Wall Mount Bracket on
it.
For convenience, the Wall Mount Bracket has fixing holes to let you easily mount an enclosure.
Turn the M5 Wrench Bolt by half at each side of the Heatsink of the enclosure.
Confidential & Proprietary
67/99
Put the enclosure with the M5 Wrench Bolt fixed on the fixing groove and fix the M5 Wrench
Bolts into the remaining fixing holes.
In this case, you will use 12 M5 Wrench Bolts in total except bolts used for the fixing groove.
ROU Rack Mount Installation
Like other units, ROU is designed to be inserted into a rack. The unit occupies around 13U of
space except cable connection.
Confidential & Proprietary
68/99
ROU component
ROU has the following components:
No.
Common Part
Unit
Remark
Enclosure
Including Rack & Wall cradle
1EA
RCPU
1EA
R_OPTIC
With SC/ACP adaptor
1EA
RPSU
Alternative DC-48V or AC 120V
1EA
Multi-Plexer
1EA
Power Cable
Optional Part
Description
RDU+BPF
- MS Connector with 3 hole to AC 120 plug(AC)
- MS Connector with 2 lug termination(DC)
800PS,800PS+900I+Paging,850C,850C+700PS,
1900P+ AWS-1 RDU, VHF+UHF(NO BPF)
Up to 3EA
to
be
inserted
Basically, the common part of ROU should have an enclosure and it is equipped with RCPU to
inquire and control state of each module, R_OPTIC to make both of electronic-optical and
optical-electronic conversions, RPSU to supply power for ROU and a Multi-Plexer to help share
multiple TX/RX signals through one antenna. It should have Power Cable for external rectifier or
to supply required power.
Confidential & Proprietary
69/99
In addition, RDU can be inserted and removed to provide service for desired band (Optional).
5.3.2
ROU Power Cabling
ROU supports both of DC-48V and AC120V of input power. As RPSU for DC-48 and RPSU for
AC120V are separated from each other, you need to select one of them in case of purchase
order.
RPSU for DC -48V and RSPU for AC 120V have the same configuration and capacity while
each of the units uses different input voltage from each other.
The following figure shows configuration of RPSUs for DC -48V and AC 120V.
Confidential & Proprietary
70/99
MC Connector
Lug Naming
RPSU Terminal naming
Remark
numbering
AC
DC
AC
DC
AC_H
-48V
AC-H
-48V
AC_N
GND
AC-N
IN_GND
GND
DC NC
FG
FG
Check if the connection is the same as one seen in the table above and make sure to turn the
power ON.
5.3.3
Optical Cabling
ROU makes optical-electronic conversion of TX signals from upper ODU and OEU and makes
electronic- optical conversion of RX signals. ROU has one optical module in it. As WDM is
installed in the R_OPTIC module, two pieces of wavelength (TX:1310nm, RX:1550nm) can be
sent/received with one optical core at the same time. ROU has SC/APC of optical adaptor type.
For optical adaptor, SC/APC type can be used. To prevent the optical access part from being
marred with dirt, it should be covered with a cap during move. When devices are connected
through optical cables, you need to clear them using alcohocol to remove dirt.
Confidential & Proprietary
71/99
Optical cables should be inserted into Optic Port outside of ROU. Using an optical slack devices
in ROU, you need to coil around one or two roll of cables to be connected with the optical
adaptor of ROPTIC.
At this time, curvature of the optical cable should be at least 10Ø to prevent insertion loss from
being increased.
Through GUI, check if PD value of ROPTIC is in a tolerable range (+4~-1dBm).
5.3.4
Insertion of RDU
ROU has slots to enable up to three RDU modules to be inserted into the unit.
You can insert a RDU into any slot. It is not possible to provide services with a RDU
module alone; you need to connect the module with Cavity BPF in any case.
The table below shows types of RDU and CAVITY BPF:
No
Unit naming
Cavity BPF
RF CABLE
Multiplexer Interface
TX
RDU 800PS
800PS BPF
RDU 850C
850C BPF
RDU
TX CABLE 1EA
RX CABLE 1EA
BPF OUT
TX CABLE 1EA
BPF TX
RX CABLE 1EA
OUT
1900P DUP
TX/RX CABLE 1EA
RDU
800PS+900I+PA
TX CABLE 1EA
RDM TX
800PS+900I+PA
BPF
RX CABLE 1EA
OUT
RDU
850C+700PS
TX CABLE 1EA
RDM TX
850C+700PS
BPF
RX CABLE 1EA
OUT
1900P+AWS-1
RDU
VHF+UHF
RX
RDM RX IN
BPF RX IN
RDM AWS+1900P
TX CABLE 1EA
RX CABLE 1EA
RDM RX IN
RDM RX IN
The following describes how to install RDU in ROU.
How to install RDU 800PS Ass’y
The following components are required:
No.
Unit
Description
RDU 800PS
RF Module
800PS BPF
BPF
800PS TX RF CABLE
SMA(M) to SMA(M), 360mm
Confidential & Proprietary
72/99
Remark
4
800PS RX RF CABLE
SMA(M) to SMA(M), 410mm
ྙ Combine RDU 800PS with 800PS BPF (As it is a plug type, push the unit to
combine with BPF.)
ྚ Insert the combined 800PS+850C BPF Ass’y into any slot of ROU.
ྛ Combination point of 800PS+800PS BPF Ass’y of the multiplexer
Interface Point
Multiplexer Port naming
Remark
800PS RDU
800PS+900I+PA TX
Confidential & Proprietary
800PS BPF
TX OUT
73/99
800PS+900I+PA RX
RX IN
How to RDU install 850C Ass’y
The following components are required:
No.
Unit
Description
Remark
RDU 850C
RF Module
850C BPF
BPF
850C TX RF CABLE
SMA(M) to SMA(M), 310mm
850C RX RF CABLE
SMA(M) to SMA(M), 310mm
ྙ Combine 850C RDU with 850C BPF (As it is a plug type, push the unit to combine
with BPF.)
ྚ Insert the combined 850C+850C BPF Ass’y into any slot of ROU.
ྛ Combination point of 850C+850C BPF Ass’y of the multiplexer
Interface Point
Multiplexer Port naming
Remark
850C RDU
Confidential & Proprietary
850C BPF
74/99
850C TX
TX OUT
850C RX
RX IN
How to install RDU 800PS+900I+PA Ass’y
The following components are required:
No.
Unit
Description
RDU 800PS+900I+PA
RF Module
800PS+900I+PA BPF
BPF
800PS+900I+PA TX RF CABLE
SMA(M) to SMA(M), 460mm
800PS+900I+PA RX RF CABLE
SMA(M) to SMA(M), 380mm
Remark
ྙ Combine RDU 800PS+900I+PA with 800PS+900I+PA BPF (As it is a plug type, push
the unit to combine with BPF.)
ྚ Insert the combined 800PS+900I+PA BPF Ass’y into any slot of ROU.
ྛ Combination point of 800PS+900I+PA BPF Ass’y of the multiplexer
Confidential & Proprietary
75/99
Interface Point
Multiplexer Port naming
Remark
800PS+900I+PA RDU
800PS+900I+PA BPF
800PS+900I+PA TX
TX OUT
800PS+900I+PA RX
RX IN
How to install RDU 850C+700PS Ass’y
The following components are required:
No.
Unit
Description
RDU 850C+700PS
RF Module
850C+700PS BPF
BPF
850C+700PS TX RF CABLE
SMA(M) to SMA(M), 470mm
850C+700PS RX RF CABLE
SMA(M) to SMA(M), 400mm
Remark
ྙ Combine RDU 850C+700PS with 850C+700PS BPF (As it is a plug type, push the unit
to combine with BPF.)
ྚ Insert the combined 850C+700PS BPF Ass’y into any slot of ROU.
ྛ Combination point of 850C+700PS BPF Ass’y of the multiplexer
Confidential & Proprietary
76/99
Interface Point
Multiplexer Port naming
Remark
850C+700PS RDU
850C+700PS BPF
850C+700PS TX
TX OUT
850C+700PS RX
RX IN
How to install RDU 1900P+AWS-1 Ass’y
The following components are required:
No.
Unit
Description
RDU 1900P+AWS-1
RF Module
1900P+AWS-1 BPF
BPF
1900P+AWS-1 RF CABLE
SMA(M) to SMA(M), 390mm
1900P+AWS-1 RF-01
SMA(M) to SMA(M)
Remark
Semirigid
ྙ Combine RDU 1900P+AWS-1 with 1900P BPF (As it is a plug type, push the unit to
combine with BPF.)
Confidential & Proprietary
77/99

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2009:11:19 17:33:54+09:00
Modify Date                     : 2009:11:19 18:22:10+09:00
Metadata Date                   : 2009:11:19 18:22:10+09:00
Document ID                     : uuid:CD3AB237E6D4DE11860890701104768D
Instance ID                     : uuid:61f4c719-73fb-4ff4-b28e-7dfc4eec3c33
Derived From Instance ID        : uuid:547209bb-6c67-4584-8809-08840744331a
Derived From Document ID        : uuid:297b8a87-4535-43e4-aa0a-ca06442e10e7
Format                          : application/pdf
Title                           : untitled
Has XFA                         : No
Page Count                      : 15
EXIF Metadata provided by EXIF.tools
FCC ID Filing: W6U150V450U

Navigation menu