Confidential & Proprietary                   63/99   If ODU is not connected in the right order, related devices may fail to communicate with each other or the unit may read wrong information. Given this, you need to connect the unit with accurate RF Port and Signal Port in a corresponding number.   For unused RF Ports for ODU expansion, make sure to terminate them using SMA Term.   When you put ODU on the top of BIU, it is recommended to install the unit at least 1U apart from BIU. Heat from BIU climbes up to reach ODU. 5.1.6  Consumption Power of BIU The table below shows power consumption of BIU: Part Unit Consumption Power Remark ShelfMCDUMCPUCommon Part MPSU7.5 W   MDBU 800PS  12W   MDBU 800PS+900I+Paging  20W   MDBU 850C  12W   MDBU 850C+700PS  19W   MDBU 1900P  20W   MDBUMDBU AWS-1  12W   BIU supplies power for ODU. Therefore, when you want to calculate total power consumption of BIU, you need to add power consumption of ODU to the total value. Power consumption of ODU is given in the later paragraph describing ODU.
Confidential & Proprietary                   64/99 5.2 ODU Installation ODU should be, in any case, put on the top of BIU. This unit gets required power and RF signals from BIU. The following table shows components of ODU: No. Unit Description  Remark Shelf  Including Main Board, 19”,1U  1EA RF Cable  SMA(F) to SMA(F), 400mm  2EA Common Part Signal Cable  2Row(15P_F) to 2Row(15P_M),650mm  1EA Optional Part  DOU  Optical Module with 4 Optic Port  Up to 2EA to be inserted 5.2.1  ODU Shelf Installation ODU is a shelf in around 1U size. Its width is 19” and so this unit should be inserted into a 19” Standard Rack. ODU should be, in any case, put on the top of BIU. BIU should be distant around 1U when the unit is installed. 5.2.2  ODU Power Cabling ODU does not operate independently. The unit should get power from BIU. When you connect 2-column, 15-pin D-SUB Signal cable from BIU and install DOU, LED on the front panel is lit. Through this LED, you can check state values of LD and PD of DOU. 5.2.3  ODU Optic Cabling As optical module shelf, ODU makes electronic-optical conversion of TX signals and then makes optical-electronic conversion of RX signals. ODU can be equipped with up to two DOUs. One DOU supports four optical ports and one optical port can be connected with ROU. Optionally, only optical port 4 can be connected with OEU. As WDM is installed in DOU, the unit can concurrently send and receive two pieces of wavelength (TX:1310nm, RX:1550nm) through one optical core. DOU has SC/APC of optical adaptor type.
Confidential & Proprietary                   65/99 Figure  5.4  –  Optical cable of SC/ACP Type For optical adaptor, SC/APC type should be used. To prevent the optical access part from being marred with dirt, it should be covered with a cap during move. When devices are connected through optical cables, you need to clear them using alcohocol to remove dirt. 5.2.4  Insert DOU to ODU   In an ODU Shelf, up to two DOUs can be installed. DOU module is in Plug in Play type. When you insert DOU in ODU, insert the unit into the left DOU1 slot first. You can be careful as the number is silk printed at the left.   The following figure shows installation diagram of ODU with one DOU inserted in it. The following figure shows installation diagram of ODU with two DOUs inserted in it.   When you insert DOU into ODU, insert the unit into the left DOU1 slot first. Into unused slot, you need to insert BLANK UNIT in any case.
Confidential & Proprietary                   66/99 5.2.5  Consumption Power of ODU   ODU gets power from BIU. One ODU can be equipped with up to two DOUs. Depending on how many DOUs are installed, power consumption varies. The table below shows power consumption of ODU: Part Unit Consumption Power Remark ODU_4  DOU 1 EA  13W   ODU_8  DOU 2 EA  26W   5.3 ROU Installation 5.3.1  ROU Enclosure installation ROU is designed to be water- and dirt-proof. The unit has the structure of One-Body enclosure. It satisfies water-proof and quake-proof standards equivalent of NEMA4. ROU can be mounted into either of a 19” Standard Rack or on a Wall.   Basically, ROU has both of a Wall Mount Bracket and a Rack Mount Bracket. Depending on the use of the Rack Mount Bracket, the bracket can be removed. The following shows dimension of the fixing point for the Wall Mount Bracket. Figure 5.5 – How to install ROU
Confidential & Proprietary                   67/99 Figure  5.6  –  Dimension used to install ROU on the WALL   ROU Wall Mount Installation Turn M12 Fixing Screws by half on the wall and fully fix the screw with a Wall Mount Bracket on it.For convenience, the Wall Mount Bracket has fixing holes to let you easily mount an enclosure.   Turn the M5 Wrench Bolt by half at each side of the Heatsink of the enclosure.
Confidential & Proprietary                   68/99 Put the enclosure with the M5 Wrench Bolt fixed on the fixing groove and fix the M5 Wrench Bolts into the remaining fixing holes. In this case, you will use 12 M5 Wrench Bolts in total except bolts used for the fixing groove. ROU Rack Mount Installation Like other units, ROU is designed to be inserted into a rack. The unit occupies around 13U of space except cable connection.
Confidential & Proprietary                   69/99 ROU componentROU has the following components: No. Unit Description  Remark Enclosure  Including Rack & Wall cradle  1EA RCPU -  1EA R_OPTIC  With SC/ACP adaptor 1EARPSU  Alternative DC-48V or AC 120V    1EA Multi-Plexer -  1EA Common Part Power Cable  - MS Connector with 3 hole to AC 120 plug(AC) - MS Connector with 2 lug termination(DC) Optional Part  RDU+BPF  800PS,800PS+900I+Paging,850C,850C+700PS, 1900P+ AWS-1 RDU, VHF+UHF(NO BPF) Up to 3EA to be inserted Basically, the common part of ROU should have an enclosure and it is equipped with RCPU to inquire and control state of each module, R_OPTIC to make both of electronic-optical and optical-electronic conversions, RPSU to supply power for ROU and a Multi-Plexer to help share multiple TX/RX signals through one antenna. It should have Power Cable for external rectifier or to supply required power.
Confidential & Proprietary                   70/99 In addition, RDU can be inserted and removed to provide service for desired band (Optional). 5.3.2  ROU Power Cabling ROU supports both of DC-48V and AC120V of input power. As RPSU for DC-48 and RPSU for AC120V are separated from each other, you need to select one of them in case of purchase order. RPSU for DC -48V and RSPU for AC 120V have the same configuration and capacity while each of the units uses different input voltage from each other. The following figure shows configuration of RPSUs for DC -48V and AC 120V.
Confidential & Proprietary                   71/99 Lug Naming  RPSU Terminal naming MC Connector numbering AC DC AC DCRemark A AC_H -48V AC-H  -48V   B AC_N GND AC-N  IN_GND   C GND DC NC FG  FG   Check if the connection is the same as one seen in the table above and make sure to turn the power ON. 5.3.3 Optical Cabling ROU makes optical-electronic conversion of TX signals from upper ODU and OEU and makes electronic- optical conversion of RX signals. ROU has one optical module in it. As WDM is installed in the R_OPTIC module, two pieces of wavelength (TX:1310nm, RX:1550nm) can be sent/received with one optical core at the same time. ROU has SC/APC of optical adaptor type. For optical adaptor, SC/APC type can be used. To prevent the optical access part from being marred with dirt, it should be covered with a cap during move. When devices are connected through optical cables, you need to clear them using alcohocol to remove dirt.
Confidential & Proprietary                   72/99 Optical cables should be inserted into Optic Port outside of ROU. Using an optical slack devices in ROU, you need to coil around one or two roll of cables to be connected with the optical adaptor of ROPTIC. At this time, curvature of the optical cable should be at least 10Ø to prevent insertion loss from being increased. Through GUI, check if PD value of ROPTIC is in a tolerable range (+4~-1dBm). 5.3.4  Insertion of RDU ROU has slots to enable up to three RDU modules to be inserted into the unit. You can insert a RDU into any slot. It is not possible to provide services with a RDU module alone; you need to connect the module with Cavity BPF in any case. The table below shows types of RDU and CAVITY BPF: Multiplexer Interface No Unit naming  Cavity BPF  RF CABLE TX RX1  RDU 800PS  800PS BPF  TX CABLE 1EA RX CABLE 1EA  BPF OUT  RDM RX IN 2  RDU 850C  850C BPF  TX CABLE 1EA RX CABLE 1EA BPF TX OUT BPF RX IN 3RDU 1900P+AWS-1  1900P DUP  TX/RX CABLE 1EA  RDM AWS+1900P 5RDU 800PS+900I+PA 800PS+900I+PA BPFTX CABLE 1EA RX CABLE 1EA RDM TX OUT RDM RX IN 6RDU 850C+700PS 850C+700PS BPFTX CABLE 1EA RX CABLE 1EA RDM TX OUT RDM RX IN 7RDU VHF+UHF -TX CABLE 1EA RX CABLE 1EA  - - The following describes how to install RDU in ROU. How to install RDU 800PS Ass’yThe following components are required:No. Unit Description  Remark 1  RDU 800PS  RF Module   2 800PS BPF  BPF   3  800PS TX RF CABLE  SMA(M) to SMA(M), 360mm
Confidential & Proprietary                   73/99 4  800PS RX RF CABLE  SMA(M) to SMA(M), 410mm    Combine ྙRDU 800PS with 800PS BPF (As it is a plug type, push the unit to combine with BPF.)  Insert the combined 800PS+850C BPF Ass’y into any slot of ROU.ྚ Combination point of 800PS+800PS BPF Ass’y of the multiplexerྛInterface Point Multiplexer Port naming 800PS RDU  800PS BPF Remark 800PS+900I+PA TX  -  TX OUT
Confidential & Proprietary                   74/99 800PS+900I+PA RX  RX IN  -   How to RDU install 850C Ass’y   The following components are required:No. Unit Description  Remark 1  RDU 850C  RF Module   2 850C BPF  BPF   3  850C TX RF CABLE  SMA(M) to SMA(M), 310mm   4  850C RX RF CABLE  SMA(M) to SMA(M), 310mm    Combine 850C RDU with 850C BPF (As it is a plug type, push the unit to combine ྙwith BPF.)  Insert the combined 850C+850C BPF Ass’y into any slot of ROU.ྚ Combination point of 850C+850C BPF Ass’y of the multiplexerྛInterface Point Multiplexer Port naming 850C RDU  850C BPF Remark
Confidential & Proprietary                   75/99 850C TX  -  TX OUT   850C RX  -  RX IN   How to install RDU 800PS+900I+PA Ass’y   The following components are required: No. Unit Description  Remark 1  RDU 800PS+900I+PA  RF Module   2 800PS+900I+PA BPF  BPF   3  800PS+900I+PA TX RF CABLE  SMA(M) to SMA(M), 460mm   4  800PS+900I+PA RX RF CABLE  SMA(M) to SMA(M), 380mm    Combine ྙRDU 800PS+900I+PA with 800PS+900I+PA BPF (As it is a plug type, push the unit to combine with BPF.)  Insert the combined ྚ800PS+900I+PA BPF Ass’y into any slot of ROU.  Combination point of ྛ800PS+900I+PA BPF Ass’y of the multiplexer
Confidential & Proprietary                   76/99 Interface Point Multiplexer Port naming 800PS+900I+PA RDU  800PS+900I+PA BPFRemark 800PS+900I+PA TX  TX OUT  -   800PS+900I+PA RX  RX IN  -   How to install RDU 850C+700PS Ass’y   The following components are required: No. Unit Description  Remark 1  RDU 850C+700PS  RF Module   2 850C+700PS BPF  BPF   3  850C+700PS TX RF CABLE  SMA(M) to SMA(M), 470mm   4  850C+700PS RX RF CABLE  SMA(M) to SMA(M), 400mm    Combine ྙRDU 850C+700PS with 850C+700PS BPF (As it is a plug type, push the unit to combine with BPF.)  Insert the combined ྚ850C+700PS BPF Ass’y into any slot of ROU.  Combination point of ྛ850C+700PS BPF Ass’y of the multiplexer
Confidential & Proprietary                   77/99 Interface Point Multiplexer Port naming 850C+700PS RDU 850C+700PS BPF Remark 850C+700PS TX  TX OUT  -   850C+700PS RX  RX IN  -   How to install RDU 1900P+AWS-1 Ass’y   The following components are required: No. Unit Description  Remark 1  RDU 1900P+AWS-1  RF Module   2 1900P+AWS-1 BPF  BPF   3  1900P+AWS-1 RF CABLE  SMA(M) to SMA(M), 390mm   4  1900P+AWS-1 RF-01  SMA(M) to SMA(M)  Semirigid  Combine ྙRDU 1900P+AWS-1 with 1900P BPF (As it is a plug type, push the unit to combine with BPF.)