Siemens RF600R2 RFID UHF Reader RF650R, RF680R, RF685R User Manual SIMATIC RF600
Siemens AG RFID UHF Reader RF650R, RF680R, RF685R SIMATIC RF600
Siemens >
Contents
- 1. User Manual part 1
- 2. User Manual part 2
- 3. User Manual
User Manual part 2
Antennas 6.4 Antenna RF642A Alignment REVIEW The following diagram shows the optimum alignment of the RF600 transponders to the RF642A antenna. Figure 6-22 Antenna/transponder alignment SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 301 Antennas 6.4 Antenna RF642A Angle deviation diagram for alignment The following diagram shows the dependence of the following factors. ● Alignment angle of transponder to antenna REVIEW ● Maximum range of antenna Figure 6-23 Angle deviation diagram for alignment SIMATIC RF600 302 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.4 Antenna RF642A 6.4.6 Parameter settings of RF642A for RF620R/RF630R Operation within the EU, EFTA, or Turkey according to DIN EN 302208 V1.4.1 Note Limitation of the radiated power according to DIN EN 302208 V1.4.1 RF600 systems that are put into operation within the EU, EFTA, or Turkey (ETSI) can be operated with an RF642A antenna with a maximum radiated power of up to 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). By adjusting the transmit power of up to 500 mW ERP (or 27 dBm ERP, 800 mW EIRP, 29.15 dBm EIRP) and taking into account the RF642A antenna gain of 6 dBi and the cable loss associated with the antenna cable (see table), the radiated power of the antenna cannot be exceeded. You can make the power settings using the "distance_limiting" parameter. You will find more detailed information on the parameters in the section Parameter assignment manual RF620R/RF630R (http://support.automation.siemens.com/WW/view/en/33287195). The national approval for RF600 systems in China means a restriction to 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). The possible combination of antenna gain (7 dbi), cable loss, and max. 500 mW transmit power of the RF630R reader means it is not possible to exceed 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). REVIEW Operation in China Operation in the USA, Canada Note Limitation of the radiated power to 4000 mW EIRP (36 dBm EIRP) with an antenna gain of 7 dBi The antenna must be commissioned by qualified personnel. Antennas with a gain >6 dBi can be put into operation, as long as the radiated power of 4000 mW EIRP (36 dBm EIRP) is not exceeded. To comply with FCC and IC-FCB requirements, the system must satisfy the following relation: • Conducted power P dBm of the RF600 reader (< 30 dBm) • Antenna gain Gi dBi in the FCC frequency band (≤ 7 dBi) • Cable loss ak dB (≥ 1 dB) P(dBm) ≤ 30 dBm - (Gi - 6 dBi) + ak SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 303 Antennas 6.4 Antenna RF642A 6.4.7 Parameter settings of RF642A for RF640R/RF670R Operation within the EU, EFTA, or Turkey according to DIN EN 302208 V1.4.1 Note Limitation of the radiated power according to DIN EN 302208 V1.4.1 RF600 systems that are put into operation within the EU, EFTA, or Turkey (ETSI) can be operated with an RF642A antenna with a maximum radiated power of 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). By setting the radiated power of up to 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP), an RF642A antenna gain of 6 dBi and taking into account the cable loss associated with the antenna cable (see table), the radiated power of the reader is correctly configured and the radiated power at the antenna is not exceeded. REVIEW Operation in China By setting a max. radiated power of 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP), an RF642A antenna gain of 7 dBi and taking into account the cable loss associated with the antenna cable (see table), the reader's radiated power is correctly configured. Operation in the USA, Canada Note Limitation of the radiated power to 4000 mW EIRP (36 dBm EIRP) with an antenna gain of 7 dBi The antenna must be commissioned by qualified personnel. Antennas with a gain >6 dBi can be put into operation, as long as the radiated power of 4000 mW EIRP (36 dBm EIRP) is not exceeded. To comply with FCC and IC-FCB requirements, the system must satisfy the following relation: • Conducted power P dBm of the RF600 reader (< 30 dBm) • Antenna gain Gi dBi in the FCC frequency band (≤ 7 dBi) • Cable loss ak dB (≥ 1 dB) P(dBm) ≤ 30 dBm - (Gi - 6 dBi) + ak SIMATIC RF600 304 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.4 Antenna RF642A 6.4.8 Setting RF642A parameters for RF650R Operation within the EU according to DIN EN 302208 V1.4.1 Note Limitation of the radiated power according to DIN EN 302208 V1.4.1 RF600 systems that are put into operation within the EU, EFTA, or Turkey (ETSI) can be operated with an RF642A antenna with a maximum radiated power of 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). By setting the radiated power of up to 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP), an RF642A antenna gain of 6 dBi and taking into account the cable loss associated with the antenna cable (see table (Page 299)), the radiated power of the reader is correctly configured and the radiated power at the antenna is not exceeded. By setting a max. radiated power of 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP), an RF642A antenna gain of 7 dBi and taking into account the cable loss associated with the antenna cable (see table (Page 299)), the reader's radiated power is correctly configured. Operation in the USA, Canada REVIEW Operation in China Note Limitation of the radiated power to 4000 mW EIRP (36 dBm EIRP) with an antenna gain of 7 dBi The antenna must be commissioned by qualified personnel. Antennas with a gain >6 dBi can be put into operation, as long as the radiated power of 4000 mW EIRP (36 dBm EIRP) is not exceeded. To comply with FCC and IC-FCB requirements, the system must satisfy the following relation: • Conducted power P dBm of the RF600 reader (< 30 dBm) • Antenna gain Gi dBi in the FCC frequency band (≤ 7 dBi) • Cable loss ak dB (≥ 1 dB) P(dBm) ≤ 30 dBm - (Gi - 6 dBi) + ak SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 305 Antennas 6.4 Antenna RF642A 6.4.9 Setting RF642A parameters for RF680R/RF685R Operation within the EU according to DIN EN 302208 V1.4.1 Note Limitation of the radiated power according to DIN EN 302208 V1.4.1 RF600 systems that are put into operation within the EU, EFTA, or Turkey (ETSI) can be operated with an RF642A antenna with a maximum radiated power of 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). By setting the radiated power of up to 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP), an RF642A antenna gain of 6 dBi and taking into account the cable loss associated with the antenna cable (see table (Page 299)), the radiated power of the reader is correctly configured and the radiated power at the antenna is not exceeded. REVIEW Operation in China By setting a max. radiated power of 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP), an RF642A antenna gain of 7 dBi and taking into account the cable loss associated with the antenna cable (see table (Page 299)), the reader's radiated power is correctly configured. Operation in the USA, Canada Note Limitation of the radiated power to 4000 mW EIRP (36 dBm EIRP) with an antenna gain of 7 dBi The antenna must be commissioned by qualified personnel. Antennas with a gain >6 dBi can be put into operation, as long as the radiated power of 4000 mW EIRP (36 dBm EIRP) is not exceeded. To comply with FCC and IC-FCB requirements, the system must satisfy the following relation: • Conducted power P dBm of the RF600 reader (< 30 dBm) • Antenna gain Gi dBi in the FCC frequency band (≤ 7 dBi) • Cable loss ak dB (≥ 1 dB) P(dBm) ≤ 30 dBm - (Gi - 6 dBi) + ak SIMATIC RF600 306 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.4 Antenna RF642A 6.4.10 Antenna patterns 6.4.10.1 Antenna radiation patterns in the ETSI frequency band Directional radiation pattern Europe (ETSI) REVIEW The directional radiation pattern is shown for nominal alignment and a center frequency of 866.3 MHz. The nominal antenna alignment is given when the antenna elevation is provided as shown in the following figure. Figure 6-24 Reference system The half-power beam width of the antenna is defined by the angle between the two -3 dB points. Which range (in %) corresponds to the dB values in the patterns can be obtained from this table . Note that the measurements presented graphically below were carried out in a low-reflection environment. Deviations can therefore occur in a normally reflecting environment. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 307 Antennas 6.4 Antenna RF642A REVIEW Directional radiation pattern in the ETSI frequency band Pattern of the vertical plane of the antenna Pattern of the horizontal plane of the antenna Figure 6-25 Directional radiation pattern of RF642A in the ETSI frequency band SIMATIC RF600 308 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.4 Antenna RF642A 6.4.10.2 Antenna radiation patterns in the FCC frequency band Directional radiation pattern USA (FCC) REVIEW The directional radiation pattern is shown for nominal alignment and a center frequency of 915 MHz. Figure 6-26 Reference system The half-power beam width of the antenna is defined by the angle between the two -3 dB points (corresponding to half the power referred to the maximum power). Which range (in %) corresponds to the dB values in the patterns can be obtained from this table . Note that the measurements presented graphically below were carried out in a low-reflection environment. Deviations can therefore occur in a normally reflecting environment. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 309 Antennas 6.4 Antenna RF642A REVIEW Directional radiation pattern of the RF642A in the FCC frequency band Pattern of the vertical plane of the antenna Pattern of the horizontal plane of the antenna Figure 6-27 Directional radiation pattern of the RF642A in the FCC frequency band SIMATIC RF600 310 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.4 Antenna RF642A 6.4.10.3 Interpretation of directional radiation patterns The following overview table will help you with the interpretation of directional radiation patterns. The table shows which dBi values correspond to which read/write ranges (in %): You can read the radiated power depending on the reference angle from the directional radiation patterns, and thus obtain information on the read/write range with this reference angle with regard to a transponder. Deviation from maximum antenna gain [dBr] Read/write range [%] 100 -3 70 -6 50 -9 35 -12 25 -15 18 -18 13 Example REVIEW The dBr values correspond to the difference between the maximum dBi value and a second dBi value. As can be seen in Directional radiation pattern in the ETSI frequency band (Page 308), the maximum antenna gain in the horizontal plane is 6 dBi. In this plane and with the parallel polarization axis at +70° or 300°, the antenna gain dropped to about 0 dBi. Therefore the dBr value is 6. The antenna range is only 70° of the maximum range at + 50° or +300° from the Z axis within the horizontal plane (see values shown in red in the directional radiation pattern: Characteristic of the vertical plane of the antenna (Page 307) and the associated representation of the reference system (Page 307)). SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 311 Antennas 6.4 Antenna RF642A 6.4.11 Technical data Table 6- 23 General technical specifications RF642A 6GT2812-1GA08 Product type designation SIMATIC RF642A Dimensions (L x W x H) 185 x 185 x 45 mm Color Pastel turquoise Material PA 12 (polyamide 12) Silicone-free Frequency band Plug connection 865 to 928 MHz 30 cm coaxial cable with RTNC coupling An antenna cable is required for connection to the reader, e.g.: 6GT2815-0BH30 Max. radiated power according to ETSI REVIEW Max. radiated power according to CMIIT Max. radiated power according to FCC • RF620R, RF630R: < 970 mW ERP • RF640R, RF670R: ≤ 1900 mW ERP • RF650R: ≤ 1900 mW ERP • RF680R/RF685R: ≤ 2000 mW ERP • RF620R, RF630R: < 1200 mW ERP • RF640R, RF670R: ≤ 2000 mW ERP • RF650R: ≤ 1900 mW ERP • RF680R/RF685R: ≤ 2000 mW ERP • RF620R, RF630R: ≤2000 mW EIRP • RF640R, RF670R: ≤4000 mW EIRP • RF650R: ≤ 3160 mW ERP • RF680R/RF685R: ≤ 4000 mW ERP Max. power 2000 mW Impedance 50 ohms Antenna gain ETSI frequency band: 6 dBi FCC frequency band: 7 dBi VSWR (standing wave ratio) max.: 1.4 Polarization Linear polarization Aperture angle for transmitting/receiving ETSI frequency band: • Horizontal plane: 75° • Vertical plane: 70° See ETSI antenna pattern FCC frequency band: • Horizontal plane: 80° • Vertical plane: 70° See FCC antenna pattern Front-to-back ratio ETSI frequency band: 10 dB FCC frequency band: 9.8 dB ± 2.2 dB SIMATIC RF600 312 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.4 Antenna RF642A 6GT2812-1GA08 Shock resistant to EN 60068-227 30 g Vibration resistant to EN 600682-6 10 g Attachment of the antenna 4 screws M4 (VESA 100 fastening system) Tightening torque ≤ 2 Nm (at room temperature) Ambient temperature • Operation • -25 ℃ to +75 ℃ • Transport and storage • -40 ℃ to +85 ℃ MTBF in years 16880 Degree of protection according to EN 60529 IP65 Weight, approx. 600 g 6.4.12 Figure 6-28 The values differ for different dimensions/materials of the mounting surface. Dimension drawing REVIEW 1) Dimensional drawing of RF642A All dimensions in mm SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 313 Antennas 6.4 Antenna RF642A 6.4.13 Approvals & certificates Table 6- 24 6GT2812-1GA08 Certificate Description Conformity in accordance with R&TTE directive in association with the readers and accessories used Table 6- 25 6GT2812-1GA08 Standard FCC CFR 47, Part 15 sections 15.247 REVIEW Federal Communications Commission Industry Canada Radio Standards Specifications Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. The FCC approval is granted in association with the FCC approval of the following RF600 readers: • FCC ID: NXW-RF600R (for RF620R: 6GT2811-5BA00-1AA1, RF630R: 6GT2811-4AA00-1AA1, RF640R: 6GT2811-3BA00-1AA0, RF670R as of FS C1: 6GT2811-0AB00-1AA0) • FCC ID: NXW-RF630R (for 6GT2811-4AA00-1AA0) • FCC ID: NXW-RF670 (for RF670R as of FS A1: 6GT2811-0AB00-1AA0) RSS-210 Issue 7, June 2007, Sections 2.2, A8 The approval for Industry Canada is granted in association with the Industry Canada approval of the following RF600 readers: • IC: 267X-RF630 (for 6GT2811-4AA00-1AA0) • IC: 267X-RF670, RF670R FS A1 (for 6GT2811-0AB00-1AA0) • IC: 267X-RF600R, Model RF620R-2 (for 6GT2811-5BA00-1AA1) • IC: 267X-RF600R, Model RF630R-2 (for 6GT2811-4AA00-1AA1) • IC: 267X-RF600R, Model RF640R (for 6GT2811-3BA00-1AA0) • IC: 267X-RF600R, model RF670R-2 as of FS C1 (for 6GT28110AB00-1AA0) This product is UL-certified for the USA and Canada. It meets the following safety standard(s): UL 60950-1 - Information Technology Equipment Safety - Part 1: General Requirements CSA C22.2 No. 60950 -1 - Safety of Information Technology Equipment UL Report E 205089 SIMATIC RF600 314 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.5 RF660A antenna 6.5 RF660A antenna 6.5.1 Description SIMATIC RF660A Features Field of application The SIMATIC RF660A is a universal medium range UHF antenna with a compact design suitable for use in industry. Frequency ranges • 865 to 928 MHz (ETSI) • 902 to 928 MHz (FCC) Polarization RH circular Suitable for RF600 transponders that can pass in parallel with the antenna regardless of their orientation. Writing/reading range max. X m Mounting 4 x M4 Connector RTNC Readers that can be connected All RF600 readers with external antenna connectors Dimensions in mm 313 x 313 x 80 Degree of protection IP67 REVIEW (VESA 100 mounting system) Frequency ranges The antenna is available for broadband. It can therefore be used for two different frequency ranges that have been specified for the regions of Europe and China/USA respectively. ● The antenna for Europe (EU, EFTA countries) operates in the frequency range of 865 to 868 MHz. ● The antenna for China, the USA, and Canada operates in the frequency range of 902 to 928 MHz. Function The SIMATIC RF660A is used to transmit and receive RFID signals in the UHF range. The antennas are connected to the SIMATIC RF600 readers via antenna cables that are available in different lengths. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 315 Antennas 6.5 RF660A antenna Ordering data Description Article number RF660A antenna for Europe (865-868) 6GT2812-0AA00 RF660A antenna for China and the USA (902-928) 6GT2812-0AA01 Ordering data accessories Description Article number Antenna mounting kit Connecting cable between reader and antenna 6GT2890-0AA00 3m (1 dB cable attenuation) 6GT2815-0BH30 5 m, suitable for drag chains (cable loss 1.25 dB) 6GT2815-2BH50 10 m (2 dB cable attenuation) 6GT2815-1BN10 10 m (4 dB cable attenuation) 6GT2815-0AN10 REVIEW 15 m, suitable for drag 6GT2815-2BN15 chains (cable loss 4.0 dB) 20 m (4 dB cable attenuation) 6.5.2 Installation and assembly 6.5.2.1 RF660A mounting types 6GT2815-0AN20 VESA 100 mounting system A standardized VESA 100 mounting system is provided to mount the antenna. The mounting system consists of four fixing holes for M4 screws at intervals of 100 mm. This is therefore suitable for: ● Mounting on metallic and non-metallic backgrounds Note To achieve optimum wave propagation, the antenna should not be surrounded by conducting objects. The area between antenna and transponder should also allow wave propagation without interference. SIMATIC RF600 316 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.5 RF660A antenna Antenna Mounting Kit The Antenna Mounting Kit allows the fine adjustment of the antenna field by setting the solid angle (see "RF600 System Manual", chapter "Antennas" > "Mounting types"). 6.5.3 Connecting an antenna to a reader The SIMATIC RF660A antenna must be connected to the reader using an antenna cable. Requirement Note Use of Siemens antenna cable REVIEW To ensure optimum functioning of the antenna, it is recommended that a Siemens antenna cable is used in accordance with the list of accessories. Figure 6-29 Rear of antenna with RTNC connection Connecting RF660A to RF640R/RF670R Preassembled standard cables in lengths of 3 m, 10 m and 20 m are available for connection. The cable between antenna and reader can be up to 20 m in length. When less than four antennas are used, we recommend that the antennas are connected to the reader as follows: Number of antennas Connections on the reader 2 antennas ANT 1, ANT 2 3 antennas ANT 1, ANT 2, ANT 3 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 317 Antennas 6.5 RF660A antenna Connecting RF660A to RF630R Preassembled standard cables in lengths of 3 m, 10 m and 20 m are available for connection. The cable between antenna and reader can be up to 20 m in length. When one antenna is used, it is recommended that the remaining antenna connection is sealed using the supplied protective cap. REVIEW 6.5.3.1 Bending radii and bending cycles of the cable Cable designation Order No. Length [m] Cable loss [dB] Bending radius [mm] Bending cycle Antenna cable 6GT28150BH30 51 1 Mal Antenna cable 6GT2815(suitable for drag 2BH50 chains) 1,25 1) 1) Antenna cable 6GT28151BN10 10 77 1 Mal Antenna cable 6GT28150BN10 10 51 1 Mal Antenna cable 6GT2815(suitable for drag 0BN20 chains) 15 1) 1) Antenna cable 20 77 1 Mal 1) 6.5.4 6GT28150BN20 With cables suitable for drag chains, 3 million bending cycles at a bending radius of 6.5 mm and bending through ± 180° are permitted. Parameter settings of RF660A for RF620R/RF630R Operation within the EU, EFTA, or Turkey according to DIN EN 302208 V1.4.1 Note Limitation of the radiated power according to EN 302 208 V1.4.1 RF600 systems that are put into operation within the EU, EFTA, or Turkey (ETSI) can be operated with an RF660A antenna with a maximum radiated power of up to 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). By adjusting the transmit power of up to 500 mW ERP (or 27 dBm ERP, 800 mW EIRP, 29.15 dBm EIRP) and taking into account the RF660A antenna gain of 7 dBi (10 dBic) and the cable loss associated with the antenna cable (see table (Page 318)), the radiated power of the antenna cannot be exceeded. You can make the power settings using the "distance_limiting" parameter. You will find more detailed information on the parameters in SIMATIC RF600 318 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.5 RF660A antenna the section Parameter assignment manual RF620R/RF630R (http://support.automation.siemens.com/WW/view/en/33287195). Operation in China The national approval for RF600 systems in China means a restriction to 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). The possible combination of antenna gain, cable loss, and max. 500 mW radiated power of the RF620R/RF630R reader means it is not possible to exceed 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). Operation in the USA, Canada Note Limitation of the radiated power to 4000 mW EIRP (36 dBm EIRP) To meet the FCC and IC-FCB requirements, the radiated power may not exceed 4000 mW EIRP (36 dBm EIRP). Therefore the system must satisfy the following relation: • Conducted power P dBm of the RF600 reader (< 30 dBm) • Antenna gain Gi dBi in the FCC frequency band (≤ 6 dBi) • Cable loss ak dB (≥ 1 dB) 6.5.5 REVIEW P(dBm) ≤ 30 dBm - (Gi - 6 dBi) + ak Parameter settings of RF660A for RF640R/RF670R Operation within the EU, EFTA, or Turkey according to DIN EN 302208 V1.4.1 Note Limitation of the radiated power according to DIN EN 302208 V1.4.1 RF600 systems that are put into operation within the EU, EFTA, or Turkey (ETSI) can be operated with an RF660A antenna with a maximum radiated power of 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). By adjusting the radiated power of up to 1300 mW ERP (or 31.15 dBm ERP, 2140 mW EIRP, 33.3 dBm EIRP), the RF660A antenna gain of 7 dBi (10 dBic) and the cable loss associated with the antenna cable (see table (Page 318)), the radiated power of the reader is correctly configured and the radiated power at the antenna is not exceeded. Operation in China By setting a max. radiated power of 1300 mW ERP (or 31.15 dBm ERP, 2140 mW EIRP, 33.3 dBm EIRP), the RF660A antenna gain of 6 dBi (9 dBic) and the cable loss associated with the antenna cable (see table (Page 318)), the radiated power of the reader is correctly configured. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 319 Antennas 6.5 RF660A antenna Operation in the USA, Canada Note Limitation of the radiated power to 4000 mW EIRP (36 dBm EIRP) To meet the FCC and IC requirements, the radiated power may not exceed 4000 mW EIRP (36 dBm EIRP). Therefore the system must satisfy the following relation: • Conducted power P dBm of the RF600 reader (< 30 dBm) • Antenna gain Gi dBi in the FCC frequency band (≤ 6 dBi) • Cable loss ak dB (≥ 1 dB) P(dBm) ≤ 30 dBm - (Gi - 6 dBi) + ak 6.5.6 Setting RF660A parameters for RF650R Operation within the EU according to DIN EN 302208 V1.4.1 Note REVIEW Limitation of the radiated power according to DIN EN 302208 V1.4.1 RF600 systems that are put into operation within the EU, EFTA, or Turkey (ETSI) can be operated with an RF660A antenna with a maximum radiated power of 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). By adjusting the radiated power of up to 1300 mW ERP (or 31.15 dBm ERP, 2140 mW EIRP, 33.3 dBm EIRP), the RF660A antenna gain of 7 dBi (10 dBic) and the cable loss associated with the antenna cable (see table (Page 318)), the radiated power of the reader is correctly configured and the radiated power at the antenna is not exceeded. Operation in China By setting a max. radiated power of 1300 mW ERP (or 31.15 dBm ERP, 2140 mW EIRP, 33.3 dBm EIRP), the RF660A antenna gain of 6 dBi (9 dBic) and the cable loss associated with the antenna cable (see table (Page 318)), the radiated power of the reader is correctly configured. SIMATIC RF600 320 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.5 RF660A antenna Operation in the USA, Canada Note Limitation of the radiated power to 4000 mW EIRP (36 dBm EIRP) To meet the FCC and IC requirements, the radiated power may not exceed 4000 mW EIRP (36 dBm EIRP). Therefore the system must satisfy the following relation: • Conducted power P dBm of the RF600 reader (< 30 dBm) • Antenna gain Gi dBi in the FCC frequency band (≤ 6 dBi) • Cable loss ak dB (≥ 1 dB) P(dBm) ≤ 30 dBm - (Gi - 6 dBi) + ak 6.5.7 Setting RF660A parameters for RF680R/RF685R Operation within the EU according to DIN EN 302208 V1.4.1 Limitation of the radiated power according to DIN EN 302208 V1.4.1 RF600 systems that are put into operation within the EU, EFTA, or Turkey (ETSI) can be operated with an RF660A antenna with a maximum radiated power of 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP). REVIEW Note By adjusting the radiated power of up to 1300 mW ERP (or 31.15 dBm ERP, 2140 mW EIRP, 33.3 dBm EIRP), the RF660A antenna gain of 7 dBi (10 dBic) and the cable loss associated with the antenna cable (see table (Page 318)), the radiated power of the reader is correctly configured and the radiated power at the antenna is not exceeded. Operation in China By setting a max. radiated power of 2000 mW ERP (or 33 dBm ERP, 3250 mW EIRP, 35 dBm EIRP), the RF660A antenna gain of 6 dBi (9 dBic) and the cable loss associated with the antenna cable (see table (Page 318)), the radiated power of the reader is correctly configured. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 321 Antennas 6.5 RF660A antenna Operation in the USA, Canada Note Limitation of the radiated power to 4000 mW EIRP (36 dBm EIRP) To meet the FCC and IC requirements, the radiated power may not exceed 4000 mW EIRP (36 dBm EIRP). Therefore the system must satisfy the following relation: • Conducted power P dBm of the RF600 reader (< 30 dBm) • Antenna gain Gi dBi in the FCC frequency band (≤ 6 dBi) • Cable loss ak dB (≥ 1 dB) REVIEW P(dBm) ≤ 30 dBm - (Gi - 6 dBi) + ak SIMATIC RF600 322 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.5 RF660A antenna 6.5.8 Antenna patterns 6.5.8.1 Antenna pattern Spatial directional radiation pattern The following schematic diagram shows the main and auxiliary fields of the RF660A antenna in free space in the absence of reflecting/absorbing materials. Please note that the diagram is not to scale. REVIEW The recommended working range lies within the main field that is shown in green. Main field (processing field) Secondary fields Figure 6-30 Main and auxiliary fields of the RF660A antenna SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 323 Antennas 6.5 RF660A antenna Radiation diagram (horizontal) Europe (ETSI) The radiation diagram is shown for horizontal alignment and for a center frequency of 865 MHz. Horizontal antenna alignment is provided when the TNC connection on the antenna points vertically up or down. The radiating/receiving angle of the antenna is defined by the angle between the two -3 dB points (corresponding to half the power referred to the maximum performance at a 0° angle). REVIEW The optimum radiating/receiving angle is therefore approximately ±30 degrees. Figure 6-31 Directional radiation pattern of the antenna (at 865 MHz, horizontal alignment) USA (FCC) The radiation diagram is shown for horizontal alignment and for a center frequency of 915 MHz. The radiating/receiving angle of the antenna is defined by the angle between the two -3 dB points (corresponding to half the power referred to the maximum performance at a 0° angle). The optimum radiating/receiving angle is therefore approximately ±35 degrees. SIMATIC RF600 324 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.5 RF660A antenna Directional radiation pattern of the antenna (at 915 MHz, horizontal alignment) 6.5.9 REVIEW Figure 6-32 Interpretation of directional radiation patterns The following overview table will help you with the interpretation of directional radiation patterns. The table shows which dBi values correspond to which read/write ranges (in %): You can read the radiated power depending on the reference angle from the directional radiation patterns, and thus obtain information on the read/write range with this reference angle with regard to a transponder. The dBr values correspond to the difference between the maximum dBi value and a second dBi value. Deviation from maximum antenna gain [dBr] Read/write range [%] 100 -3 70 -6 50 -9 35 -12 25 -15 18 -18 13 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 325 Antennas 6.5 RF660A antenna Example As one can see from the section Antenna pattern (Page 323), the maximum antenna gain is 6 dBi. In the vertical plane, the antenna gain has dropped to approx. 3 dBi at +30°. Therefore the dBr value is -3. The antenna range is only 50% of the maximum range at ± 30° from the Z axis within the vertical plane. 6.5.10 Technical data Table 6- 26 General technical specifications RF660A 6GT2812-0AA00 6GT2812-0AA01 ETSI FCC, CMIIT Product type designation SIMATIC RF660A Dimensions (L x W x H) 313 x 313 x 80 mm Color Pastel turquoise Material PA 12 (polyamide 12) REVIEW Silicone-free Frequency band 865 to 868 MHz Plug connection RTNC 902 to 928 MHz Max. radiated power according to ETSI • RF620R, RF630R: < 1200 mW ERP • RF640R, RF670R: < 2000 mW ERP • RF650R: < 2000 mW ERP • RF680R/RF685R: < 2000 mW ERP SIMATIC RF600 326 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.5 RF660A antenna Max. radiated power according to CMIIT 6GT2812-0AA00 6GT2812-0AA01 ETSI FCC, CMIIT • RF620R, RF630R: < 1000 mW ERP • RF640R, RF670R: < 2000 mW ERP • RF650R: < 2000 mW ERP • RF680R/RF685R: Max. radiated power according to FCC • RF620R, RF630R: < 1600 mW EIRP • RF640R, RF670R: < 4000 mW EIRP • RF650R: < 4000 mW EIRP • RF680R/RF685R: < 4000 mW EIRP Max. power 2000 mW Impedance 50 ohms Antenna gain 7 dBi (5-7 dBic) VSWR (standing wave ratio) Max. 2:1 Polarization RH circular Aperture angle for transmitting/receiving 55° - 60° 60° - 75° Front-to-back ratio Attachment of the antenna 4 screws M4 (VESA 100 mount system) Tightening torque ≤ 2 Nm 6 dBi (> 6 dBic) REVIEW < 2000 mW ERP (at room temperature) Ambient temperature • Operation • -20 °C to +70 °C • Transport and storage • -40 °C to +85 °C MTBF in years 2 x 109 Degree of protection according to EN 60529 IP67 Weight, approx. 1.2 kg SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 327 Antennas 6.5 RF660A antenna 6.5.11 Dimension drawing Figure 6-33 Dimension drawing RF660A REVIEW All dimensions in mm (± 0.5 mm tolerance) SIMATIC RF600 328 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.5 RF660A antenna 6.5.12 Approvals & certificates Table 6- 27 6GT2812-0AA00 Certificate Description Conformity in accordance with R&TTE directive in association with the readers and accessories used Table 6- 28 6GT2812-0AA01 Standard FCC CFR 47, Part 15 sections 15.247 Industry Canada Radio Standards Specifications The FCC approval is granted in association with the FCC approval of the following RF600 readers: • FCC ID: NXW-RF600R (for RF620R: 6GT2811-5BA00-1AA1, RF630R: 6GT2811-4AA00-1AA1, RF640R: 6GT2811-3BA00-1AA0, RF670R as of FS C1: 6GT2811-0AB00-1AA0) • FCC ID: NXW-RF630R (for 6GT2811-4AA00-1AA0) • FCC ID: NXW-RF670 (for RF670R as of FS A1: 6GT2811-0AB00-1AA0) REVIEW Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. RSS-210 Issue 7, June 2007, Sections 2.2, A8 The approval for Industry Canada is granted in association with the Industry Canada approval of the following RF600 readers: • IC: 267X-RF630 (for 6GT2811-4AA00-1AA0) • IC: 267X-RF670, RF670R FS A1 (for 6GT2811-0AB00-1AA0) • IC: 267X-RF600R, Model RF620R-2 (for 6GT2811-5BA00-1AA1) • IC: 267X-RF600R, Model RF630R-2 (for 6GT2811-4AA00-1AA1) • IC: 267X-RF600R, Model RF640R (for 6GT2811-3BA00-1AA0) • IC: 267X-RF600R, model RF670R-2 as of FS C1 (for 6GT28110AB00-1AA0) This product is UL-certified for the USA and Canada. It meets the following safety standard(s): UL 60950-1 - Information Technology Equipment Safety - Part 1: General Requirements CSA C22.2 No. 60950 -1 - Safety of Information Technology Equipment UL Report E 205089 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 329 Antennas 6.6 Mounting types 6.6 Mounting types 6.6.1 Overview The following readers and antennas feature a standardized VESA 100 fixing system (4 x M4): ● SIMATIC RF620R/RF630R/RF640R/RF670R ● SIMATIC RF640A ● SIMATIC RF660A It is used to fix the above-mentioned antennas in place through a mounting plate or the antenna mounting kit. REVIEW 6.6.2 Ordering data Description Machine-Readable Product Code Antenna mounting kit 6GT2890-0AA00 SIMATIC RF600 330 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Antennas 6.6 Mounting types 6.6.3 Mounting with antenna mounting kit Flexible mounting is possible using the antenna mounting kit. An antenna can then be rotated through any angle in space. Antenna mounting kit Description Swivel range of wall mounting (1) Wall side (2) Antenna side REVIEW Distances for wall mounting SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 331 Antennas 6.6 Mounting types Antenna mounting kit Description VESA adapter plate from VESA 75 x 75 to VESA 100 x 100 The VESA adapter plate is required for fixing the antenna to the antenna mounting kit. REVIEW Hole drilling template for fixing the antenna mounting kit to the wall SIMATIC RF600 332 System Manual, xx/2014, J31069-D0171-U001-A15-7618 7 Transponder/tags 7.1 Overview 7.1.1 Mode of operation of transponders/tags The tag/transponder mainly comprises a microchip with an integral memory and a dipole antenna. The principle of operation of a passive RFID transponder is as follows: ● Diversion of some of the high-frequency energy emitted by the reader to supply power to the integral chip ● Commands received from reader REVIEW ● Responses are transmitted to the reader antenna by modulating the reflected radio waves (backscatter technique) Figure 7-1 Mode of operation of transponders The transmission ranges achieved vary in accordance with the size of the tag and the corresponding dipole antenna. In general the following rule applies: The smaller the tag and therefore the antenna, the shorter the range. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 333 Transponder/tags 7.1 Overview 7.1.2 Transponder classes and generations The transponder classes are distinguished by the different communication protocols used between the reader and transponder. Transponder classes are mostly mutually incompatible. The following transponder classes are supported by the RF 600 system: ● EPC Global Class 1 Gen 2 with full EPC Global Profile (ISO 18000-6C) Support for protocol types using the RF600 The definition of the transponders/tags according to ISO 18000-6 (corresponds to EPC Global Class 1 Gen 2) refers to implementation of the air-interface protocols. EPC Global RF600 supports the EPCglobal class 1. EPCglobal class 1 includes passive tags with the following minimum characteristics: ● EPC ID (Electronic Product Code IDentifier) ● Tag ID ● A function which permanently ensures that tags no longer respond. REVIEW ● Optional use or suppression of tags ● Optional password-protected access control ● Optional USER memory area. The programming is performed by the customer (cannot be reprogrammed after locking) 7.1.3 Electronic Product Code (EPC) The Electronic Product Code (EPC) supports the unique identification of objects (e.g. retail items, logistical items or transport containers). This makes extremely accurate identification possible. In practical use, the EPC is stored on a transponder (tag) and scanned by the reader. There are different EPC number schemes with different data lengths. Below is the structure of a GID-96-bit code (EPC Global Tag Data Standards V1.1 Rev. 1.27) : SIMATIC RF600 334 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.1 Overview ● Header: This identifies the EPC identification number that follows with regard to length, type, structure and version of the EPC ● EPC manager: This identifies the company/corporation ● Object class: Corresponds to the article number ● Serial number: Consecutive number of the article The Siemens UHF transponders are all suitable for working with EPC and other number schemes. Before a transponder can work with a number scheme, the relevant numbers must first be written to the transponder. REVIEW Allocation of the ECP ID by the tag manufacturer Figure 7-2 Allocation of the EPC ID on delivery of the tag SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 335 Transponder/tags 7.1 Overview 7.1.4 SIMATIC memory configuration of the RF600 transponders and labels SIMATIC memory configuration REVIEW The following graphic shows the structure of the virtual SIMATIC memory for the RF620R/RF630R reader and explains the function of the individual memory areas. The SIMATIC memory configuration is based on the 4 memory banks, as they are defined in EPC Global. Figure 7-3 SIMATIC memory areas of the RF600 transponders SIMATIC RF600 336 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.1 Overview Special memory configuration of the RF600 transponders and labels Tags Chip type User [hex] EPC TID Access FF00-FF0B (96 bits = FF00-FF0B) read/ write FFC0-FFC7 RF630L Impinj (-2AB02) Monza 4QT 00 - 3F FF00-FF0F (96 bits = FF00-FF0B) read/ write RF630L NXP G2XM (-2AB03) 00 - 3F FF00-FF1D (96 bits = FF00-FF0B) RF680L NXP G2XM 00 - 3F RF610T NXP G2XM RF610T ATEX RF620T Special KILL-PW Lock function FF80-FF87 Yes Yes FFC0-FFC9 FF80-FF87 Yes Yes read/ write FFC0-FFC7 FF80-FF87 Yes Yes FF00-FF1D (96 bits = FF00-FF0B) read/ write FFC0-FFC7 FF80-FF87 Yes Yes 00 - 3F FF00-FF1D (96 bits = FF00-FF0B) read/ write FFC0-FFC7 FF80-FF87 LOCKED Yes NXP G2XM 00 - 3F FF00-FF1D (96 bits = FF00-FF0B) read/ write FFC0-FFC7 FF80-FF87 LOCKED Yes Impinj Monza 4QT 00 - 3F FF00-FF0F (96 bits = FF00-FF0B) read/ write FFC0-FFC9 FF80-FF87 LOCKED Yes Impinj Monza 4QT 00 - 3F FF00-FF0F (96 bits = FF00-FF0B) read/ write FFC0-FFC9 FF80-FF87 LOCKED Yes RF630T NXP G2XM 00 - 3F FF00-FF1D (96 bits = FF00-FF0B) read/ write FFC0-FFC7 FF80-FF87 LOCKED Yes RF640T NXP G2XM 00 - 3F FF00FF1D0B (96 bits = FF00-FF0B) read/ write FFC0-FFC7 FF80-FF87 LOCKED Yes RF680T NXP G2XM 00 - 3F FF00-FF1D (96 bits = FF00-FF0B) read/ write FFC0-FFC7 FF80-FF87 LOCKED Yes RF630L (-2AB00, -2AB01) Impinj Monza 2 1) 1) REVIEW Range (preset length) RESERVED (passwords) RF622T RF625T 1) 1) Uses User Memory Indicator (UMI). SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 337 Transponder/tags 7.1 Overview Note Default EPC ID REVIEW When an RF610T-RF680T transponder is supplied, a 12 byte long identifier is assigned by the manufacturer as the EPC ID according to a number scheme (see "Assignment of the ECP ID by the manufacturer"). SIMATIC RF600 338 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.1 Overview Memory map of the ISO 18000-6C Monza 2 chip according to EPC The memory of the ISO 18000-6C Monza 2 chip is divided logically into four different memory banks: Memory bank (decimal) Memory type Description MemBank 112 USER User-writable USER memory area MemBank 102 TID Is defined by the manufacturer, contains the class identifier and serial number of a transponder. MemBank 012 EPC Contains the EPC UID, the protocol and the CRC of a transponder. You can write to the EPC memory area. In the delivery condition, the memory contents can have the following states: MemBank 002 RESERVED • empty • containing the same data • containing different data Contains the access and kill password. REVIEW The graphic below illustrates the exact memory utilization. Each box in the right part of the graphic represents one word (16 bits) in the memory. Color Mode of access by RF600 reader Read Write / read * Can only be overwritten with RF6xxL transponders. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 339 Transponder/tags 7.1 Overview Memory map of the ISO 18000-6C Monza 4QT chip according to EPC The memory of the ISO 18000-6C Monza 4QT chip is divided logically into four different memory banks: Memory bank (decimal) Memory type Description MemBank 112 USER User-writable USER memory area MemBank 102 TID Is defined by the manufacturer, contains the class identifier and serial number of a transponder. MemBank 012 EPC Contains the EPC data, the protocol information and the CRC data of a transponder. You can write to the EPC memory area. In the delivery condition, the memory contents can have the following states: MemBank 002 RESERVED • containing the same data • containing different data Contains the access and kill password. REVIEW The graphic below illustrates the exact memory utilization. Each box in the right part of the graphic represents one word (16 bits) in the memory. SIMATIC RF600 340 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Transponder/tags 7.1 Overview Color Mode of access by RF600 reader Read Write / read * Can only be overwritten with RF6xxL transponders. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 341 Transponder/tags 7.1 Overview Memory map of the ISO 18000-6C G2XM chip according to EPC The memory of the ISO 18000-6C G2XM chip is divided logically into four different memory banks: Memory bank (decimal) Memory type Description MemBank 112 USER User-writable USER memory area MemBank 102 TID Is defined by the manufacturer, contains the class identifier and serial number of a transponder. MemBank 012 EPC Contains the EPC data, the protocol information and the CRC data of a transponder. You can write to the EPC memory area. In the delivery condition, the memory contents can have the following states: MemBank 002 RESERVED • containing the same data • containing different data Contains the access and kill password. REVIEW The graphic below illustrates the exact memory utilization. Each box in the right part of the graphic represents one word (16 bits) in the memory. SIMATIC RF600 342 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Transponder/tags 7.1 Overview Color Mode of access by RF600 reader Read Write / read * Can only be overwritten with RF6xxL transponders. Parameter assignment Which parameter assignment options available to you for which reader of the RF600 family is outlined in the section "Overview of parameterization of RF600 reader (Page 461)". Detailed information on parameter assignment as well as examples for describing and reading specific memory areas can be found in the referenced sections of the documentation. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 343 Transponder/tags 7.1 Overview 7.1.5 Minimum distances and maximum ranges The following section describes the configuration of the antenna and transponder relative to each other. The aim of the section is to help you achieve the maximum ranges listed here in a typical electromagnetic environment. One of the main focuses of the section is the effect of the mounting surface of the transponder on the write/read distance. As the requirements for achieving the maximum distances specified here, note the following points: ● Operate the readers with the maximum possible and permitted transmit power. ● With external antennas, the antenna cable 6GT2815-0BH30 with a length of 3 m and 1 dB cable loss is used. ● The alignment of the transponder and antenna needs to be optimum (see section "Configurations of antenna and transponder (Page 344)"). ● The optimum mounting surface for the transponder has been selected (see section "Effects of the materials of the mounting surfaces on the range (Page 346)") ● The maximum range shown in the section "Maximum read/write ranges of transponders (Page 347)" applies only to read operations. REVIEW With write operations, the range is reduced as described in the section. ● Effects that reduce read/write ranges have been avoided (see section "Antenna configurations (Page 43)"). 7.1.5.1 Configurations of antenna and transponder Below, you will find several possible antenna-transponder configurations that are necessary to achieve the maximum range. With the RF620A and RF642A antennas, the polarization axes of the antenna and of the transponder must be aligned parallel to each other. Note Reduction of the maximum read/write range when using RF620A or RF642A antennas If the alignment of the polarization axes between the RF620A or RF642A antennas and transponders is not parallel, this reduces the read/write range. The reduction in the range depends on the angular deviation between the polarization axes of the RF620A or RF642A antenna and the polarization axis of the transponder. You will find further details in the section "Alignment of transponders to the antenna (Page 254)" or "Alignment of transponders to the antenna (Page 300)". SIMATIC RF600 344 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.1 Overview Possible transponder alignments depending on the antenna type To achieve the maximum read/write range with RF640A or RF660A antennas, make sure that the planes of the polarization axes have the same alignment. Changing the transponder angle within the x-y plane has no effect on the range. Antenna RF640A or RF660A Transponder Figure 7-4 Possible transponder alignment with RF640A or RF660A To achieve the maximum range with RF620A or RF642A antennas, make sure that the polarization axes of the antenna and transponder are parallel to each other. Changing the transponder angle within the x-y plane leads to a reduction of the range. ① ② REVIEW ① ② Antenna RF620A or RF642A Transponder Figure 7-5 Possible transponder alignment with RF620A or RF642A SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 345 Transponder/tags 7.1 Overview If the angle is changed within the y-z plane, this causes a reduction in range for all antenna types. ① ② Antenna RF620A, RF640A, RF642A or RF660A Transponder REVIEW Figure 7-6 Transponder alignment not allowed Note Optimum transponder position/alignment Depending on the electromagnetic properties of the environment, the optimum transponder position and alignment may differ from those shown above. 7.1.5.2 Effects of the materials of the mounting surfaces on the range Effects due to antenna mounting For the RF640A, RF642A and RF660A antennas, the antenna gain and therefore the maximum read/write range does not depend on the selected material of the mounting surface. In contrast to this, the antenna gain of the RF620A antenna and therefore the maximum read/write range of transponders does depend on the mounting surface of the antenna. To achieve the maximum range with an RF620A antenna, the antenna needs to be mounted on a metallic surface of at least 150 x 150 mm. You will find more detailed information on antenna gain in the subsections of the section "Antenna patterns (Page 257)". SIMATIC RF600 346 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.1 Overview Effects due to transponder mounting The maximum read/write range of the transponders depends on the material of the mounting surface. The specified ranges apply when mounted on non-metallic surfaces, such as paper or card, with the RF625T, RF630T and RF640T when mounted on metal. Mounting on plastic can reduce the maximum read/write range considerably depending on the type of plastic (up to 70%). When mounted on wood, the range is furhter reduced the more moisture the wood contains. Due to the attenuating properties of glass, direct mounting without a spacer can halve the range. If the RF625T, RF630T, RF640T or RF680T transponders are mounted on metal, this metallic surface acts as a reflection surface. This surface should therefore be adequately large. To achieve the listed maximum ranges, transponders must be mounted on a metallic mounting surface with a minimum diameter of 150 mm, for the RF630T and RF680T 300 mm. If the metallic mounting surface only has a diameter of 65 mm instead of the required 150 mm, the range is reduced by 65%. 7.1.5.3 Maximum read/write ranges of transponders Table 7- 1 Read ranges of transponders at a room temperature of +25 °C (all ranges in m) SIMATIC RF630L SIMATIC RF630L SIMATIC RF680L SIMATIC RF610T 6GT2810-2AB03 SIMATIC RF620T 2.5 with RF620A 1.6 0.8 1.6 with RF640A 4.5 2.8 2.2 2.8 4.5 with RF642A 5.5 3.5 2.8 3.5 5.5 with RF660A with internal antenna 3.5 4.5 with RF620A 2.2 1.4 1.1 1.4 2.2 with RF640A 3.1 with RF642A with RF660A 6GT2810-2AB00, 6GT2810-2AB01, 6GT2810-2AB020AX0 1) REVIEW Maximum read ranges SIMATIC RF620R with internal antenna SIMATIC RF630R SIMATIC RF640R SIMATIC RF650R with RF620A with RF640A with RF642A with RF660A SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 347 Transponder/tags 7.1 Overview SIMATIC RF630L 6GT2810-2AB00, 6GT2810-2AB01, 6GT2810-2AB020AX0 SIMATIC RF630L SIMATIC RF680L SIMATIC RF610T 6GT2810-2AB03 SIMATIC RF620T 1) SIMATIC RF670R with RF620A 2.2 1.4 1.1 1.4 2.2 with RF640A with RF642A with RF660A SIMATIC RF680R with RF620A with RF640A with RF642A with RF660A SIMATIC RF685R with internal antenna with RF620A REVIEW with RF640A with RF642A with RF660A SIMATIC RF625T 2) SIMATIC RF630T 2) SIMATIC RF640T 2) SIMATIC RF680T 2) 0.8 2.5 5.5 with RF620A 0.3 0.3 0.8 1.3 with RF640A 0.8 0.7 2.2 3.5 with RF642A 1.1 0.8 2.8 with RF660A 1.2 0.9 with internal antenna 1.3 3.5 with RF620A 0.4 0.3 1.1 1.8 with RF640A 1.2 0.9 with RF642A 1.5 1.2 with RF660A 1.5 1.2 SIMATIC RF620R with internal antenna SIMATIC RF630R SIMATIC RF640R SIMATIC RF650R with RF620A with RF640A with RF642A with RF660A SIMATIC RF600 348 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.1 Overview SIMATIC RF625T 2) SIMATIC RF630T 2) SIMATIC RF640T 2) SIMATIC RF680T 2) with RF620A 0.4 0.3 1.1 1.8 with RF640A 1.2 0.9 with RF642A 1.5 1.2 with RF660A 1.5 1.2 SIMATIC RF670R SIMATIC RF680R with RF620A with RF640A with RF642A with RF660A SIMATIC RF685R with internal antenna with RF620A with RF640A with RF642A 1) Mounting on a non-metallic surface. Mounting surface with a minimum diameter of 300 mm. Mounting on metal is not possible. 2) Mounting on metal Mounting surface with a minimum diameter of 150 mm, for the RF630T and RF680T 300 mm. Maximum write ranges REVIEW with RF660A Depending on the transponder type, the reader antenna requires more power for writing than for reading data. When writing, the maximum range reduces by approximately 30% compared with the read range. 7.1.5.4 Minimum distances between antennas and transponders The antennas listed here are all far field antennas. For this reason, a minimum distance between antennas and transponders must be maintained to ensure reliable transponder data access: Table 7- 2 Minimum distances to be maintained between antennas and transponders RF600 antenna Minimum distances to be maintained RF620A 50 mm RF640A 200 mm RF642A 200 mm RF660A 200 mm SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 349 Transponder/tags 7.2 SIMATIC RF630L Smartlabel 7.2 SIMATIC RF630L Smartlabel 7.2.1 Features SIMATIC RF630L smart labels are passive, maintenance-free data carriers based on UHF Class 1 Gen2 technology that are used to store the "Electronic Product Code" (EPC). Smart labels offer numerous possible uses for a wide range of applications and support efficient logistics throughout the process chain. SIMATIC RF630L transponder 6GT2810-2AB00 6GT2810-2AB01 6GT2810-2AB02-0AX0 6GT2810-2AB03 REVIEW Design Area of application Simple identification such as barcode replacement or supplementation, through warehouse and distribution logistics, right up to product identification. Memory EPC 96 bits EPC 96/128 bits EPC 96/240 bits Additional user memory No 64 bytes 64 bytes Range 1) max. 8 m max. 5 m Mounting Self-adhesive paper labels, for example for attaching to packaging units, paper or cartons Self-adhesive plastic labels, for example for attaching to packaging units, paper or cartons Not suitable for fixing straight onto metal or onto liquid containers The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) SIMATIC RF600 350 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.2 SIMATIC RF630L Smartlabel 7.2.2 RF630L transponder Article number Packaging RF630L transponder, SmartLabel 101.6 mm x 152.4 mm (4" x 6") 6GT2810-2AB00 Minimum order 1600 items (800 on one roll) RF630L transponder, 6GT2810-2AB01 SmartLabel 101.6 mm x 50.8 mm (4" x 2") Minimum order 1000 items (1000 on one roll) RF630L transponder, SmartLabel 97 mm x 27 mm 6GT2810-2AB020AX0 Minimum order 5000 items (5000 on one roll) RF630L transponder, SmartLabel 54 mm x 34 mm 6GT2810-2AB03 Minimum order 2000 items (2000 on one roll) Minimum spacing between labels REVIEW 7.2.3 Ordering data Figure 7-7 Minimum spacing between labels The specified minimum spacing applies for the SIMATIC RF630L smart labels with the following order numbers: ● 6GT2810-2AB00 ● 6GT2810-2AB01 ● 6GT2810-2AB02-0AX0 ● 6GT2810-2AB03 Table 7- 3 Minimum spacing Name Minimum spacing 50 mm 50 mm SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 351 Transponder/tags 7.2 SIMATIC RF630L Smartlabel Please note that smart labels can also be attached one above the other. The spacing between the labels attached one above the other depends on the damping characteristics of the carrier material. 7.2.4 Memory configuration of the smart label The memory configuration of the smart label is described in the section SIMATIC memory configuration of the RF600 transponders and labels (Page 336). 7.2.5 REVIEW Table 7- 4 Technical data Mechanical data 6GT2810-2AB00 6GT2810-2AB01 6GT2810-2AB02-0AX0 6GT2810-2AB03 Dimensions (L x W) 101.6 mm x 152.4 mm (ca. 4" x 6") 101.6 mm x 50.8 mm (ca. 4" x 2") 97 mm x 27 mm 54 mm x 34 mm Design Paper with integrated antenna Plastic with integrated antenna Label type Paper label Inlay Antenna material Aluminum Static pressure 10 N/mm2 Material surface Paper Type of antenna Shortened dipole Color white Printing Can be printed using heat transfer technique Mounting Single-sided adhesive (self-adhesive label). Single-sided adhesive (self-adhesive inlay). Degree of protection None, the label must be protected against humidity. IP65 Weight approx. 3 g approx. 1 g Table 7- 5 Plastic PET Transparent approx. 2 g Electrical data 6GT2810-2AB00 Air interface ISO 18 000-6 Type C Polarization type Linear Polarization direction The polarization direction is parallel with the short side of the paper label Frequency range 860 to 960 MHz Range 1) max. 8 m 6GT2810-2AB01 6GT2810-2AB02-0AX0 6GT2810-2AB03 The polarization direction is parallel with the long side of the paper label The polarization direction is parallel with the long side of the inlay max. 5 m SIMATIC RF600 352 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.2 SIMATIC RF630L Smartlabel 6GT2810-2AB00 6GT2810-2AB01 6GT2810-2AB02-0AX0 6GT2810-2AB03 Minimum spacing between labels • Vertically • 50 mm • Horizontally • 100 mm Energy source Field energy via antenna, without battery Multitag capability Yes The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)" 1) Table 7- 6 Memory specifications 6GT2810-2AB00 Type EPC Class 1 Gen2 Memory organization EPC 96 bits 6GT2810-2AB01 Listing ISO 18000-6C Data retention at +25 °C 10 years Read cycles Unlimited Write cycles 100.000 Anti collision approx. 100 labels/sec Table 7- 7 6GT2810-2AB03 EPC 96/128 bits EPC 96/240 bits 64 bytes 64 bytes REVIEW Additional user memory No 6GT2810-2AB02-0AX0 Environmental conditions 6GT2810-2AB00 6GT2810-2AB01 6GT2810-2AB02-0AX0 6GT2810-2AB03 Temperature range during operation -40 °C … 65 °C, up to 80 °C (200 cycles) Temperature range during storage The label should be stored in the range of +15°C and +25°C at a humidity of 40% to 60%. Storage duration Two years, determined by the shelf life of the adhesive Torsion and bending load Partially permissible Distance from metal Not suitable for fixing straight onto metal Table 7- 8 Identification 6GT2810-2AB00 6GT2810-2AB01 6GT2810-2AB02-0AX0 6GT2810-2AB03 CE CE approval to R&TTE FCC Passive labels or transponders comply with the valid regulations; certification is not required. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 353 Transponder/tags 7.2 SIMATIC RF630L Smartlabel REVIEW 7.2.6 Dimension drawings Figure 7-8 SIMATIC RF630L 6GT2810-2AB00 dimension drawing Figure 7-9 SIMATIC RF630L 6GT2810-2AB01 dimension drawing Figure 7-10 Dimension drawing SIMATIC RF630L 6GT2810-2AB02-0AX0 SIMATIC RF600 354 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.2 SIMATIC RF630L Smartlabel SIMATIC RF630L 6GT2810-2AB03 dimension drawing REVIEW Figure 7-11 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 355 Transponder/tags 7.3 SIMATIC RF680L Smartlabel 7.3 SIMATIC RF680L Smartlabel 7.3.1 Features The SIMATIC RF680L Smartlabel is passive and maintenance-free. It functions based on the UHF Class 1 Gen 2 technology and is used for saving the electronic product code (EPC) of 96 bits/240 bits. The label also has a 512 bit user memory. The SIMATIC RF680L is a heat-resistant Smartlabel with a limited service life. Its target use is the direct identification of objects in high-temperature applications. Thanks to its antenna geometry, the transponder can be read from any direction. However, the range is reduced if it is not aligned in parallel with the antenna. REVIEW SIMATIC RF680L Smartlabel Features Area of application Production logistics applications subject to high temperatures Air interface according to ISO°18000-6C Memory EPC 96 bit/240 bit Add-on-memory 64 bytes Range 1) max. 4 m Mounting Via a hole on the narrow side. Can also be glued by customer. The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) SIMATIC RF600 356 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.3 SIMATIC RF680L Smartlabel 7.3.2 Delivery format The SIMATIC RF680L is supplied on a roll. One roll always contains 1000 Smartlabels. You can tear off the Smartlabel from the roll at the perforation. Cardboard tube, inner dia 76 mm Roll label Perforation Figure 7-12 7.3.3 REVIEW ① ② ③ SIMATIC RF680L roll Ordering data Ordering data Article number Packaging SIMATIC RF680L 6GT2810-2AG80 1,000 units on a roll • Smartlabels 54 x 89 mm • heat-resistant SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 357 Transponder/tags 7.3 SIMATIC RF680L Smartlabel 7.3.4 Minimum spacing between labels Figure 7-13 Minimum spacing between labels Table 7- 9 Minimum spacing REVIEW Minimum spacing 7.3.5 20 mm 50 mm Memory configuration of the smart label The memory configuration of the smart label is described in the section SIMATIC memory configuration of the RF600 transponders and labels (Page 336). SIMATIC RF600 358 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.3 SIMATIC RF680L Smartlabel Mounting on metal Figure 7-14 Metal mounting surface Figure 7-15 Mounting on metal REVIEW 7.3.6 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 359 REVIEW Transponder/tags 7.3 SIMATIC RF680L Smartlabel 7.3.7 Technical data 7.3.7.1 Mechanical data Feature Description Dimensions (L x W) 156 mm x 40 mm Thickness of the label 0.4 mm (±25% incl.. chip) Design Synthetic paper; PEEK Antenna material Copper Static pressure 10 N/mm2 Transponder arching max. 6 mm (see "Dimension drawing") Silicone-free Yes Type of antenna Shortened dipole Color beige Printing Yes, customized Mounting Via a hole on the narrow side. Can also be glued by customer. Weight Approx. 3 g 7.3.7.2 Electrical data Characteristic Description Air interface According to ISO 18 000-6 C Polarization type Linear Polarization direction The polarization direction is parallel with the long side of the inlay Frequency range • Europe 865 to 868 MHz • USA 902 to 928 MHz Range 1) max. 4 m Minimum spacing between labels • Vertically • 50 mm • Horizontally • 20 mm Energy source Field energy via antenna, without battery Multitag capability Yes The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) SIMATIC RF600 360 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.3 SIMATIC RF680L Smartlabel 7.3.7.4 7.3.8 Memory specifications Property Description Type EPC Class 1 Gen 2 Memory organization EPC code 96 bits/240 bits User memory 64 bytes TID 64 bits Reserved (passwords) 64 bits Protocol ISO 18000-6C Data retention time 10 years Read cycles Unlimited Write cycles Minimum at +22 °C 100 000 Environmental conditions Property Description Temperature range during operation -25 °C … +85 °C (permanent) +200 °C up to six hours +220 °C up to one hour +230 °C for a short time Temperature range during storage -40 °C … +85 °C Torsion and bending load Partially permissible Distance from metal Whole surface not suitable for fixing straight onto metal (see chapter Mounting on metal (Page 359)) REVIEW 7.3.7.3 Certificates and approvals Certificate Description Conformity with R&TTE directive FCC Federal Communications Commission RoHS Passive labels and transponders comply with the valid regulations; certification is not required. Compliant according to EU Directive 2002/95/EC SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 361 Transponder/tags 7.3 SIMATIC RF680L Smartlabel 7.3.9 SIMATIC RF680L REVIEW Figure 7-16 Dimension drawing SIMATIC RF600 362 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.4 SIMATIC RF610T 7.4 SIMATIC RF610T 7.4.1 Features The SIMATIC RF610T is passive and maintenance-free. It operates based on the UHF Class 1 Gen 2 technology and is used for saving the electronic product code (EPC) of 96 bits / 240 bits. The label also has a 512 bit user memory. The SIMATIC RF610T offers a host of possible uses for a wide range of applications and supports efficient logistics throughout the entire process chain. Thanks to its antenna geometry, the transponder can be read from any direction. However, the range is reduced if it is not aligned in parallel with the antenna. SIMATIC RF610T Features Area of application • Simple identification, such as barcode replacement or barcode supplement • Warehouse and distribution logistics REVIEW • Product identification For the Food & Beverage sector, a special version can be supplied on request that is certified for use in contact with food. Air interface according to ISO°18000-6C Memory EPC 96 bit/240 bit Add-on-memory 64 bytes Range 1) max. 5 m Mounting • Suspended by means of cable ties, or similar • Can also be fixed with screws or glued by customer. • Not suitable for mounting straight onto metal. The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) 7.4.2 Ordering data Ordering data Article number Packaging SIMATIC RF610T 6GT2810-2BB80 Min. order quantity 500 units SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 363 Transponder/tags 7.4 SIMATIC RF610T 7.4.3 Safety instructions for the device/system Note This device/system may only be used for the applications described in the catalog and the technical documentation "System manual MOBY D, RF200, RF300, RF600 (http://support.automation.siemens.com/WW/view/en/10805817) and only in combination with third-party devices and components recommended and/or approved by Siemens. Minimum spacing between labels REVIEW 7.4.4 Figure 7-17 Minimum spacing between labels Table 7- 10 Minimum spacing Minimum spacing 7.4.5 20 mm 50 mm Memory configuration of the transponder The memory configuration of the transponder is described in the section SIMATIC memory configuration of the RF600 transponders and labels (Page 336). SIMATIC RF600 364 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.4 SIMATIC RF610T 7.4.6 Technical data 7.4.6.1 Mechanical data Feature Description Dimensions (L x W x H) 86 mm x 54 mm x 0.4 mm Design PVC (polyvinyl chloride) Antenna material Aluminum Static pressure 10 N/m2 Type of antenna Shortened dipole Color white Printing Can be printed using heat transfer technique Mounting 7.4.6.2 Suspended by means of cable ties, or similar Can also be fixed with screws or glued by customer. • Not suitable for mounting straight onto metal. Approx. 3 g Electrical data Characteristic Description Air interface According to ISO 18 000-6 C Polarization type Linear Polarization direction The polarization direction is parallel with the long side of the inlay Frequency range • Europe 865 … 868 MHz • USA 902 … 928 MHz Range 1) max. 5 m Energy source Field energy via antenna, without battery Multitag capability Yes REVIEW Weight • • The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 365 Transponder/tags 7.4 SIMATIC RF610T 7.4.6.3 REVIEW 7.4.6.4 Memory specifications Property Description Type EPC Class 1 Gen 2 Memory organization EPC code 96 bits/240 bits User memory 512 bits TID 64 bits Reserved (passwords) 64 bits Protocol ISO 18000-6C Data retention time 10 years Read cycles Unlimited Write cycles Minimum at +22 °C 100 000 Environmental conditions Feature Description Temperature range during operation -25 °C … +85 °C Temperature range during storage -40 °C … +85 °C Shock resistant acc. to EN 60068-2-27 Vibration acc. to EN 60068-2-6 100 g1 50 g1 Torsion and bending load Partially permissible Distance from metal Not suitable for fixing straight onto metal Degree of protection IP67 The values for shock and vibration are maximum values and must not be applied continuously. 1) Note Note that in temperature ranges > 70 °C, the transponder can become slightly deformed. However, this has no effect on the transponder function. SIMATIC RF600 366 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.4 SIMATIC RF610T 7.4.7 Certificates and approvals Certificate Description Conformity with R&TTE directive FCC Federal Communications Commission Passive labels and transponders comply with the valid regulations; certification is not required. This product is UL-certified for the USA and Canada. It meets the following safety standard(s): UL508 - Industrial Control Equipment CSA C22.2 No. 142 - Process Control Equipment • UL Report E 120869 Dimension drawing REVIEW 7.4.8 • • Figure 7-18 Dimensional drawing of SIMATIC RF610T All dimensions in mm SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 367 Transponder/tags 7.5 SIMATIC RF610T ATEX 7.5 SIMATIC RF610T ATEX 7.5.1 Features The SIMATIC RF610T special variant ATEX is passive and maintenance-free. It operates based on the UHF Class 1 Gen 2 technology and is used for saving the electronic product code (EPC) of 96 bits / 240 bits. The label also has a 512 bit user memory. The SIMATIC RF610T special variant ATEX provides numerous possible uses for a wide range of applications and allows efficient logistics throughout the entire process chain. Thanks to its antenna geometry, the transponder can be read from any direction. However, the range is reduced if it is not aligned in parallel with the antenna. SIMATIC RF610T Features Area of application • Simple identification, such as barcode replacement or barcode supplement • Warehouse and distribution logistics REVIEW • Product identification For the Food & Beverage sector, a special version can be supplied on request that is certified for use in contact with food. Air interface according to ISO°18000-6C Memory EPC 96 bit/240 bit Add-on-memory 64 bytes Range 1) max. 5 m Mounting • Suspended by means of cable ties, or similar • Can also be fixed with screws or glued by customer. • Not suitable for mounting straight onto metal. The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) 7.5.2 Ordering data Ordering data Article number Packaging SIMATIC RF610T special variant ATEX 6GT2810-2BB80-0AX1 Min. order quantity 500 units SIMATIC RF600 368 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.5 SIMATIC RF610T ATEX 7.5.3 Safety instructions for the device/system NOTICE Approved use This device/system may only be used for the applications described in the catalog and the technical documentation "System manual MOBY D, RF200, RF300, RF600 (http://support.automation.siemens.com/WW/view/en/10805817) and only in combination with third-party devices and components recommended and/or approved by Siemens. Minimum spacing between labels REVIEW 7.5.4 Figure 7-19 Minimum spacing between labels Table 7- 11 Minimum spacing Minimum spacing 7.5.5 a (horizontal) 20 mm b (vertical) 50 mm Memory configuration The memory configuration of the transponder is described in section SIMATIC memory configuration of the RF600 transponder and labels (Page 336). SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 369 Transponder/tags 7.5 SIMATIC RF610T ATEX 7.5.6 Technical specifications 7.5.6.1 Mechanical data Feature Description Dimensions (L x W x H) 86 mm x 54 mm x 0.4 mm Design PVC (polyvinyl chloride) Antenna material Aluminum Static pressure 10 N/m2 Type of antenna Shortened dipole Color white Printing Can be printed using heat transfer technique Mounting REVIEW Weight 7.5.6.2 • Suspended by means of cable ties, or similar • Can also be fixed with screws or glued by customer. • Not suitable for mounting straight onto metal. Approx. 3 g Electrical data Characteristic Description Air interface According to ISO 18 000-6 C Polarization type Linear Polarization direction The polarization direction is parallel with the long side of the inlay Frequency range Europe: 865 ... 868 MHz USA: 902 to 928 MHz Range 1) max. 5 m Energy source Field energy via antenna, without battery Multitag capability Yes The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) SIMATIC RF600 370 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.5 SIMATIC RF610T ATEX 7.5.6.4 Memory data Feature Description Type EPC Class 1 Gen 2 Memory organization EPC code 96 bits/240 bits User memory 64 bytes TID 64 bits Reserved (passwords) 64 bits Protocol ISO 18000-6C Data retention time 10 years Read cycles Unlimited Write cycles Minimum 100 000 at +22 °C Environmental conditions Feature Description Temperature range during operation -25 °C … +85 °C Temperature range during storage -40 °C … +85 °C Shock resistant acc. to EN 60068-2-27 Vibration acc. to EN 60068-2-6 100 g 1) 50 g 1) Torsion and bending load Partially permissible Distance from metal Not suitable for fixing straight onto metal Degree of protection IP67 REVIEW 7.5.6.3 The values for shock and vibration are maximum values and must not be applied continuously. 1) Note Note that in temperature ranges > 70 °C, the transponder can become slightly deformed. However, this has no effect on the transponder function. 7.5.6.5 Use of the transponder in the Ex protection area In a conformity declaration, TÜV NORD CERT GmbH has confirmed compliance with the essential health and safety requirements relating to the design and construction of equipment and protective systems intended for use in potentially explosive areas as per Annex II of the directive 94/9/EG. The essential health and safety requirements are satisfied in accordance with standards EN 60079-0: 2009, EN 60079-11: 2007 and EN 61241-11: 2006. This allows the RF610T special variant ATEX transponder to be used in hazardous areas for gases, for the device category 3 G and gas group IIB, or alternatively in hazardous areas for dusts, for the device category 3 D and group IIIB. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 371 Transponder/tags 7.5 SIMATIC RF610T ATEX Identification The identification is as follows: II 3 G Ex ic IIB T6 to T4 or Use of the transponder in hazardous areas for gases REVIEW 7.5.6.6 II 3 D Ex ic IIIB T120°C, -25 °C < Ta < +85 °C Note The labeling of the front of the transponder shown above is an example and can vary between batches produced at different times. This does not affect the haradous area marking. Temperature class delineation for gases The temperature class of the transponder for hazardous areas depends on the ambient temperature range: Ambient temperature range Temperature class -25 °C to +85 °C T1 - T4 -25 °C to +65 °C T5 -25 °C to +50 °C T6 SIMATIC RF600 372 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.5 SIMATIC RF610T ATEX WARNING Ignitions of gas-air mixtures When using the RF610T transponder, check to make sure that the temperature class is adhered to in keeping with the requirements of the area of application Non-compliance with the permitted temperature ranges while using the transponder can lead to ignitions of gas-air mixtures. WARNING Ignitions of gas-air mixtures The maximum radiated power of the transmitter used to operate the transponder must not exceed 2000 mW ERP. Non-compliance with the permitted radiated power can lead to ignitions of gas-air mixtures. 7.5.6.7 Use of the transponder in hazardous areas for dusts REVIEW The equipment is suitable for dusts whose ignition temperatures for a dust layer of 5 mm are higher than 190 °C (smoldering temperature). The ignition temperature specified here according to EN 60079-0 and EN 61241-11 for ignition protection type ic in this case references the smoldering temperature of a layer of combustible flyings (ic IIIA) or alternatively non-conductive dusts (ic IIIB). Temperature class delineation for dusts Ambient temperature range Temperature value -25 °C < Ta < +85 °C T120 °C WARNING Ignitions of dust-air mixtures When using the RF610T transponder, make sure that the temperature values are adhered to in keeping with the requirements of the area of application. Non-compliance with the permitted temperature ranges while using the transponder can lead to ignitions of dust-air mixtures. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 373 Transponder/tags 7.5 SIMATIC RF610T ATEX 7.5.7 Certificates and approvals Certificate Description Compatible with R&TTE directive For directive 94/9/EC: conformity declaration no. TÜV 11 ATEX 081778 FCC Federal Communications Commission Dimension drawing REVIEW 7.5.8 Passive labels and transponders comply with the valid regulations; certification is not required. Figure 7-20 Dimension drawing SIMATIC RF610T (special variant ATEX) All dimensions in mm SIMATIC RF600 374 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.6 SIMATIC RF620T 7.6 SIMATIC RF620T 7.6.1 Characteristics The SIMATIC RF620T Transponder is passive and maintenance-free, based on the UHF Class 1 Gen2 technology for storing 96-bit/128-bit electronic product codes (EPC). The transponder also has a 64-byte user memory. The container tag for industrial applications is rugged and highly resistant to detergents. It is designed for easy attachment onto plastic, wood, glass, e.g. containers, palettes, and trolleys The optimum functionality/range of the RF620T on metal is achieved by means of the spacer. Since the plastic is food safe, it is also suitable for use in the food-processing industry. This container tag is designed for the frequency bands of 860 MHz and 960 MHz and can be operated in combination with our UHF system RF660. Features Area of application Transponder for rugged, industrial requirements such as RF identification in warehouses and the logistics and transport area. Frequency range 860 to 960 MHz Polarization Linear Memory EPC 96 bit/128 bit Additional USER memory 64 bytes Range 1) max. 8 m Mounting • Screw, bond • On metal by means of spacers ① Labeling area Housing color REVIEW SIMATIC RF620T Transponder You can inscribe the transponder itself using laser, or adhere a label to position ①. Possible types of labeling: • Barcode • Inscription in plain text • Data matrix code Anthracite The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 375 Transponder/tags 7.6 SIMATIC RF620T 7.6.2 Ordering data Ordering data Article number SIMATIC RF620T 6GT2810-2HC81 • Frequency 865 MHz to 928 MHz, • UHF Class 1 Gen2 technology (96 bit/128 bit) • -25 °C to +85 °C operating temperature • Dimensions (L x W x H) 127 x 38 x 6 mm • IP67 degree of protection Spacer for SIMATIC RF620T • For attaching to metal surfaces • Dimensions (L x W x H) 155 x 38 x 12 mm 6GT2898-2AA00 Planning the use 7.6.3.1 Optimum antenna/transponder positioning with planar mounting of the transponder on metal REVIEW 7.6.3 Figure 7-21 Example of optimum reader-transponder positioning with RF620R and RF640R via the internal reader antenna. SIMATIC RF600 376 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.6 SIMATIC RF620T 7.6.3.2 Range when mounted on flat metallic carrier plates Figure 7-22 Optimum positioning of the transponder on a (square or circular) metal surface Table 7- 12 Range with metallic, flat carriers without spacers Carrier material Range Metal plate at least 300 x 300 mm typically 38% Table 7- 13 REVIEW The transponder generally has linear polarization. The polarization axis runs as shown in the diagram below. If the tag is mounted in the center of a flat metal plate, which is either approximately square or circular, it can be aligned in any direction since the transmitting and receiving RF660A antennas operate with circular polarization. Range with flat metallic carriers with spacers Carrier material Range Metal plate at least 300 x 300 mm typically 87% The use of spacers on metallic surfaces is recommended. On rectangular carrier plates, the range depends on the mounting orientation of the transponder A 90° rotation of the transponder about the axis of symmetry may result in greater ranges. You will find more detailed information on the range in the section "Minimum distances and maximum ranges (Page 344)". SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 377 Transponder/tags 7.6 SIMATIC RF620T 7.6.3.3 Influence of conducting walls on the range If there are conducting walls or restrictions in the vicinity that could affect the wireless field, a distance of approx. 10 cm is recommended. In principle, walls have least influence if the polarization axis is orthogonal to the wall. A spacer must be used in any case. Range: One conducting wall Influence on the range when positioned orthogonally to the conducting wall REVIEW View from above Distance d 20 mm 50 mm 100 mm Range approx. 100% approx. 100% approx. 100% Wall height 20 mm approx. 100% approx. 100% approx. 100% Wall height 50 mm approx. 80% approx. 100% approx. 100% Wall height 100 mm SIMATIC RF600 378 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.6 SIMATIC RF620T Influence on the range when positioned parallel to the conducting wall View from above Distance d 20 mm 50 mm 100 mm Range approx. 70% approx. 100% approx. 100% Wall height 20 mm approx. 60% approx. 90 % approx. 100% Wall height 50 mm approx. 30% approx. 70% approx. 100% Wall height 100 mm REVIEW Range: Two conducting walls Influence on the range when positioned against two conducting walls View from above Side view Distance d 20 mm 50 mm 100 mm Range approx. 70% approx. 100% approx. 100% Wall height 20 mm approx. 60% approx. 90 % approx. 100% Wall height 50 mm approx. 30% approx. 70% approx. 100% Wall height 100 mm The values specified in the tables above are guide values. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 379 Transponder/tags 7.6 SIMATIC RF620T 7.6.3.4 Directional radio pattern of the transponder on metallic surfaces Preferably, align the data carrier parallel to the transmitting antenna. If, however, the data carrier including the metallic carrier plate is tilted, the reading range will be reduced. REVIEW Rotation about the polarization axis or orthogonal to the polarization axis Figure 7-23 Characteristic of the transponder when rotated about the polarization axis or orthogonally to the polarization axis SIMATIC RF600 380 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.6 SIMATIC RF620T 7.6.3.5 Range when mounted on non-metallic carrier materials The transponder is generally designed for mounting on non-metallic objects which provide the conditions for the maximum reading ranges Table 7- 14 Range with non-metallic carriers Carrier material Range Transponder on wooden carrier (dry, degree of moisture < 15%) typically 75 % Transponder on plastic carrier typically 75 % Transponder on glass typically 75 % Transponder on plastic mineral water bottle typically 15 % The maximum range of 100% is achieved by mounting the transponder in a free space with low reflections on a metal-free carrier with a diameter of at least 300 mm. You will find more detailed information on the range in the section "Minimum distances and maximum ranges (Page 344)". Directional radio pattern of the transponder on non-metallic surfaces Preferably, align the data carrier parallel to the transmitting antenna. If, however, the data carrier including the metallic carrier plate is tilted, the reading range will be reduced. Rotation about the polarization axis Figure 7-24 REVIEW 7.6.3.6 Rotation of the transponder about the polarization axis Generally the range does not change when the transponder without carrier material is rotated about the polarization axis. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 381 Transponder/tags 7.6 SIMATIC RF620T REVIEW Rotation orthogonal to the polarization axis Figure 7-25 Transponder characteristics when rotated orthogonally to the polarization axis (within the tag plane) If the transponder is positioned orthogonally to the transmitting antenna, it normally cannot be read. Therefore the data carrier is preferably to be aligned parallel to the transmitting antenna. The following figure illustrates this situation. SIMATIC RF600 382 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Transponder/tags 7.6 SIMATIC RF620T Figure 7-26 Application example for possible orientations of the transponder. 7.6.3.7 Range when mounted on ESD carrier materials The transponder is generally designed for mounting on non-conductive objects which provide the conditions for the maximum reading ranges The conductive or dissipative surface of ESD materials limits the range depending on the surface resistance. Generally, dissipative materials with a surface resistance of 1 x 105 to 1 x 1011 ohm and conductive materials with 1 x 103 to 1 x 105 ohm are available. Table 7- 15 Limited range with ESD materials Carrier material Range Transponder on electrostatic dissipative materials, dimensions 60°x°40 cm approx. 50% (surface resistance 2 x 109 ohm) Transponder on electrostatically conductive materials, dimensions 60 x 40 cm (surface resistance 1 x 104 ohm) Use of spacers approx. 12% approx. 25 % SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 383 Transponder/tags 7.6 SIMATIC RF620T REVIEW 100% range is achieved when mounted in free space with low reflections. With multitag capability, the range may be limited further. Figure 7-27 Schematic representation of how the range depends on the surface resistance of the ESD material In the figure above, the two reading points are shown illustrating the range as a percentage dependent on the surface resistance. At the same time a linear dependence between the reading points is to be expected, however with measurement inaccuracies. The darker the hatching, the greater the probability that the reading point is found in the hatched area. SIMATIC RF600 384 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.6 SIMATIC RF620T 7.6.3.8 Communication with multiple transponders REVIEW The RF600 system is multitag-capable. This means that the reader can detect and write to several transponders almost simultaneously. The minimum distance between the transponders is ≥ 50 mm. Figure 7-28 Multitag reading 7.6.4 Mounting instructions NOTICE Level mounting Please note that both the transponder and the spacer must be mounted on a level surface. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 385 Transponder/tags 7.6 SIMATIC RF620T NOTICE The screw fixing element was tested with the types of screws, spring washers and plain washers indicated below. Depending on the application area, the user must use similar, correspondingly certified screws, spring washers and plain washers (e.g. for the food processing industry). EJOT screws can be additionally etched and passivated in some areas of the food processing industry, e.g if they made of stainless steel A2. In other areas without special requirements, the screws can be, for example, zinc plated and blue passivated. Note In case of high mechanical loads (such as shocks or vibration), the transponder must be fixed onto the spacer by means of screws. Properties Description Mounting type • • Screw mounting (e.g. 2 x M4 hexagon socket head cap screws DIN 6912, spring lock and grommet DIN 433) or glued • Transponder on spacer • Clips or screw on the side of the clip, or 2°x° screws (e.g. EJOT PT ® WN 5411 35x10 VZ crosshead screw/torx) • Spacer • Screw mounting (e.g.°2 x M4 hexagon socket head cap screws DIN 6912, spring lock and grommet DIN 433) or glued or secured with tape REVIEW Transponder Tightening torque 7.6.5 Graphics (at room temperature) < 1.2 Nm Memory configuration of the transponder The memory configuration of the transponder is described in the section SIMATIC memory configuration of the RF600 transponders and labels (Page 336). SIMATIC RF600 386 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.6 SIMATIC RF620T 7.6.6 Technical Specifications 7.6.6.1 Mechanical data Property Description Dimensions (L x W x H) • Transponder • 127 x 38 x 6 mm • Spacer • 157 x 39 x 12 mm Design Plastic enclosure (PP; food safe), silicon-free Housing color Anthracite Weight Transponder • Approx. 18 g • Spacer • Approx. 22 g • Transponder with spacer • Approx. 40 g Mounting on metal 7.6.6.2 Preferably with spacer Electrical data Characteristic Description Air interface According to ISO 18 000-6 C Frequency range 860 ... 960 MHz Range 1) max. 8 m Polarization type Linear Energy source Magnetic energy via antenna, without battery Multitag capability Yes, minimum distance between data carriers ≥ 50 mm REVIEW • Mounting on a flat metal-free carrier with a diameter of at least 300 mm and at room temperature. The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) 7.6.6.3 Memory specifications Characteristic Description Type EPC Class 1 Gen2 Memory organization EPC code 96/128 bit User memory 64 byte Protocol ISO 18000-6C Data retention time 10 years Read cycles Unlimited Write cycles 100 000 min. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 387 Transponder/tags 7.6 SIMATIC RF620T 7.6.6.4 7.6.6.5 Environmental conditions Property Description Temperature range during operation -25 °C to +85 °C Temperature range during storage -40 °C to +85 °C Shock Vibration compliant with EN 60721-3-7 Class 7 M3 100 g, 50 g Torsion and bending load Not permissible Degree of protection IP67 Chemical resistance of the transponder RF620T The following table provides an overview of the chemical resistance of the data memory made of polypropylene. Concentration 20 °C 50 °C Low ○○○○ ○○○○ Emissions containing hydrochloric acid ○○○○ ○○○○ Emissions containing sulphuric acid ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ REVIEW Emissions alkaline/containing hydrogen fluoride /carbon dioxide Battery acid 38 Aluminum acetate, w. Aluminum chloride ○○○○ ○○○○ Aluminum nitrate, w. 10 ○○○○ ○○○○ Aluminum salts ○○○○ ○○○○ Formic acid 50 ○○○○ Aminoacetic acid (glycocoll, glycine) 10 ○○○○ ○○○○ Ammonia gas Ammonia Ammonia, w. ○○○○ ○○○○ 25 ○○○○ ○○○○ conc. ○○○○ ○○○○ 10 ○○○○ ○○○○ Arsenic acid, w. ○○○○ ○○○○ Ascorbic acid, w. ○○○○ ○○○○ Petroleum spirit Benzene Prussic acid, w. Sodium hypochlorite solution diluted / 20 50 Borax Boric acid, w. Brake fluid 10 ○○ ○○○○ ○○○○ ○○○○ ○○ ○○ ○○ ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ SIMATIC RF600 388 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.6 SIMATIC RF620T Concentration Bromine techn. pure Butyl acetate (acetic acid butyl ester) 50 °C ○○○○ ○○○○ ○○ Calcium chloride, w./ alcoholic ○○○○ ○○○ Calcium chloride, ○○○○ ○○○○ Calcium nitrate, w. ○○○○ ○○○○ ○○○○ ○○○○ 50 Chlorine Chloroacetic acid Chloric acid 20 Chrome baths, tech. ○○○○ ᅳ ᅳ ○○○○ 10 ○○○○ ○○○○ 20 / 50 ○○ ○○ ○○○○ ○○ Chromic acid, w Chromosulphuric acid ᅳ ○○○○ ○○○○ Chromium salts Chromic acid ᅳ ○○○○ conc. 10 ○○○○ ○○○○ Diesel oil 100 ○○○○ Diglycole acid 30 ○○○○ ○○○○ Iron salts, w. k. g. ○○○○ ○○○○ ○○○○ ○○○○ 5 / 50 ○○○○ ○○○○ Ethanol 50 / 96 ○○○○ ○○○○ Ethyl alcohol 96 / 40 ○○○○ ○○○○ Citric acid Diesel fuel ○○○○ Vinegar Acetic acid Fluoride ○○○○ ○○○○ 10 ○○○○ ○○○○ 40 ○○○○ ○○○ Formaldehyde solution 30 ○○○○ ○○○○ Glycerin any ○○○○ ○○○○ ○○○○ ○○○○ Formaldehyde Glycol Uric acid ○○○○ HD oil, motor oil, without aromatic compounds ○○○○ Fuel oil ○○○○ Isopropanol techn. pure Potassium hydroxide, w. Potassium hydroxide Silicic acid Lysol ○○○○ ○○○○ ○○○○ 10 / 50 ○○○○ ○○○○ any ○○○○ ○○○○ ○○○○ ○○○○ saturated ○○○○ ○○○○ ○○○○ ○○ Common salt Carbonic acid ○○○○ REVIEW Butane, gas, liquid 20 °C SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 389 Transponder/tags 7.6 SIMATIC RF620T Concentration 20 °C 50 °C Magnesium salts, w. k. g. ○○○○ ○○○○ Magnesium salts any ○○○○ ○○○○ Machine oil 100 ○○○○ Sea water Methanol Methyl alcohol, w. 50 Lactic acid, w. Lactic acid ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ ○○○ ○○○○ ○○○○ ○○○○ k. g. ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ Sodium hydroxide solution, w. ○○○○ ○○○○ Nickel salts, w. Nickel salts k. g. ○○○○ Sodium hydroxide, w. Sodium hydroxide solution REVIEW ○○○○ 80 Sodium carbonate Sodium chloride, w. ○○○○ 3 / 85 Engine oil Sodium carbonate, w. (soda) ○○○○ 30 / 45 / 60 ○○○○ ○○○○ k. g. ○○○○ ○○○○ saturated ○○○○ ○○○○ Nitrobenzol ○○○ ○○ Oxalic acid ○○○○ ○○○○ Petroleum Phosphoric acid Phosphoric acid, w techn. pure ○○○○ 1-5 / 30 ○○○○ ○○○○ 85 ○○○○ ○○○ ○○○○ 20 ○○○○ Propane liquid ○○○○ Propane gaseous ○○ Mercury pure ○○○○ ○○○○ Crude oil 100 ○○○○ ○○ Ammonium chloride 100 ○○○○ ○○○○ ○○○○ ○○○○ Ammonium chloride, w. Nitric acid Hydrochloric acid Sulphur dioxide Sulphuric acid 50 ○○ 1-10 ○○○○ ○○○○ 1-5 / 20 ○○○○ ○○○○ 35 ○○○○ ○○○ conc. ○○○○ ○○○○ Low ○○○○ ○○○○ moist ○○○○ ○○ liquid 1-6 / 40 / 80 ○○○○ ○○○○ 20 ○○○○ ○○○ 60 ○○○○ ○○ SIMATIC RF600 390 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.6 SIMATIC RF620T Hydrogen sulphide Detergent Concentration 20 °C 50 °C 95 ○○ fuming Low/saturated ○○○○ ○○○○ High ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ ○○ Water Hydrogen techn. pure Plasticizer 7.6.7 Resistant ○○○ Virtually resistant ○○ Limited resistance ○ Less resistant ᅳ Not resistant w. Aqueous solution k. g. Cold saturated Certificates and approvals Table 7- 16 6GT2810-2HC00 - RF620T UHF container tag Certificate REVIEW Abbreviations ○○○○ Description CE Approval to R&TTE Table 7- 17 6GT2810-2HC80 - RF620T UHF container tag Standard FCC Federal Communications Commission Passive labels or transponders comply with the valid regulations; certification is not required. This product is UL-certified for the USA and Canada. It meets the following safety standard(s): • UL508 - Industrial Control Equipment • CSA C22.2 No. 142 - Process Control Equipment • UL Report E 120869 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 391 Transponder/tags 7.6 SIMATIC RF620T Dimension drawing REVIEW 7.6.8 Figure 7-29 SIMATIC RF620T UHF container tag Units of measurement: All dimensions in mm Tolerances, unless indicated otherwise, are +-0.5 mm. ① Labeling area, see Section Characteristics (Page 375) SIMATIC RF600 392 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.7 SIMATIC RF622T 7.7 SIMATIC RF622T 7.8 SIMATIC RF625T 7.8.1 Characteristics The SIMATIC RF625T transponder is a passive, maintenance-free data carrier with a round design. It operates based on the UHF Class 1 Gen 2 technology and is used to save the "Electronic Product Code" (EPC) of 96 bits/128 bits. The transponder also has a 512-bit user memory. The areas of application are industrial asset management, RF identification of tools, containers and metallic equipment. The Disk Tag is small and rugged and suitable for industrial applications with degree of protection IP68. It is highly resistant to oil, grease and cleaning agents. SIMATIC RF625T Features Area of application Identification tasks in rugged industrial environments Frequency variants Europe USA/Canada 865 MHz ... 868 MHz 902 MHz ... 928 MHz Air interface according to ISO°18000-6C Polarization Linear Memory EPC 96 bit/128 bit Add-on-memory 64 bytes Range 1) max. 1.5 m Mounting for direct mounting on conductive materials (preferably metal). REVIEW Ideally, the SIMATIC RF625T is mounted directly on a flat metal surface of at least 150 mm diameter where it achieves a typical sensing distance of 1.5 m. The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) 7.8.2 Ordering data Ordering data Article number SIMATIC RF625T (Europe), frequency range 865 MHz ... 868 MHz 6GT2810-2EE00 SIMATIC RF625T (USA / Canada), frequency range 902 MHz ... 928 MHz 6GT2810-2EE01 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 393 Transponder/tags 7.8 SIMATIC RF625T 7.8.3 Planning the use 7.8.3.1 Optimum antenna/transponder positioning with planar mounting of the transponder on metal Figure 7-30 Example of optimum reader/antenna transponder positioning REVIEW The graphic shows an example of optimum positioning of the transponder relative to the reader or the antenna. This positioning is regardless of whether you are working with the internal reader antenna or with one of the external RF600 antennas. SIMATIC RF600 394 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.8 SIMATIC RF625T 7.8.3.2 Range when mounted on flat metallic carrier plates Figure 7-31 Optimum positioning of the transponder on a (square or circular) metal surface Table 7- 18 Range on flat metallic carriers Carrier material Range Metal plate of at least Ø 150 mm 100 % Metal plate Ø 120 mm approx. 70% Metal plate Ø 85 mm approx. 60% Metal plate Ø 65 mm approx. 60% REVIEW The transponder generally has linear polarization. The polarization axis runs as shown in the diagram below. If the tag is mounted in the center of a flat metal plate, which is either approximately square or circular, it can be aligned in any direction since the transmitting and receiving RF660A antennas operate with circular polarization. On rectangular carrier plates, the range depends on the mounting orientation of the transponder You will find more detailed information on the range in the section "Minimum distances and maximum ranges (Page 344)". SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 395 Transponder/tags 7.8 SIMATIC RF625T 7.8.3.3 Range when mounted on non-metallic carrier materials The transponder is generally designed for mounting on metallic objects which provide the conditions for the maximum reading ranges Table 7- 19 Range with non-metallic carriers Carrier material Range Transponder on wooden carrier approx. 60% Transponder on plastic carrier approx. 65 % Transponder on plastic mineral water bottle approx. 70% Transponder without base approx. 50 % The maximum range of 100% is achieved by mounting the transponder in a free space with low reflections on a flat metal carrier with a diameter of at least 150 mm. You will find more detailed information on the range in the section "Minimum distances and maximum ranges (Page 344)". 7.8.3.4 Influence of conducting walls on the range REVIEW If there are conducting walls or restrictions in the vicinity that could affect the wireless field, a distance of approx. 10 cm is recommended. In principle, walls have least influence if the polarization axis is orthogonal to the wall. SIMATIC RF600 396 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.8 SIMATIC RF625T Range: One conducting wall Influence on range when positioned against one conducting wall View from above Distance d 20 mm 50 mm 100 mm Range approx. 100% approx. 100% approx. 100% Wall height 20 mm approx. 100% approx. 100% approx. 100% Wall height 50 mm approx. 80% approx. 100% approx. 100% Wall height 100 mm REVIEW Range: Two conducting walls Influence on the range when positioned against two conducting walls View from above Side view Distance d 20 mm 50 mm 100 mm Range approx. 70% approx. 75 % approx. 100% approx. 70% approx. 80% approx. 100% Wall height 50 mm approx. 70% approx. 40% approx. 50 % Wall height 100 mm Wall height 20 mm The values specified in the tables above are guide values. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 397 Transponder/tags 7.8 SIMATIC RF625T 7.8.3.5 Mounting in metal It is possible to mount the transponder in metal. If there is not enough clearance to the surrounding metal, this reduces the reading range. Clearance (all-round) Reading range 1) a = 5 mm Approx. 50 % a = 10 mm Approx. 70% The read range information applies when the transponder is mounted on a metallic carrier with a diameter of at least 150 mm. REVIEW 1) Figure 7-32 Flush-mounting of RF625T in metal SIMATIC RF600 398 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.8 SIMATIC RF625T 7.8.3.6 Directional radiation pattern of the transponder Directional diagram in the ETSI frequency band (Europe) REVIEW The directional diagram is shown for nominal alignment and a center frequency of 866.3 MHz. The nominal transponder alignment is achieved when the transponder is viewed as shown in the following figure. Figure 7-33 Reference system of the RF625T Ideally, align the data carrier parallel with the transmitting antenna or the reader. If the data carrier including the (metallic) carrier plate is tilted, the reading range will be reduced. The following diagrams show the effects on the reading range depending on the carrier material and the angle of inclination of the transponder. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 399 Transponder/tags 7.8 SIMATIC RF625T REVIEW Directional characteristics of the transponder when mounted on a metallic carrier Figure 7-34 Directional characteristics of the RF625T on a metallic carrier depending on the angle of inclination in a vertical or horizontal direction SIMATIC RF600 400 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.8 SIMATIC RF625T REVIEW Directional characteristics of the transponder when mounted on a non-metallic carrier Figure 7-35 Directional characteristics of the RF625T on a non-metallic carrier depending on the angle of inclination in a vertical or horizontal direction SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 401 Transponder/tags 7.8 SIMATIC RF625T 7.8.4 Mounting instructions Properties Description Type of installation Secured with screw ①, (M3 counter-sunk head screw) Tightening torque (at room temperature) ≤ 1.0 Nm Figure 7-36 Screw mounting REVIEW Note Make sure that the mounting surface is even when mounting the transponder. 7.8.5 Memory configuration of the transponder The memory configuration of the transponder is described in the section SIMATIC memory configuration of the RF600 transponders and labels (Page 336). 7.8.6 Technical Specifications 7.8.6.1 Mechanical data Property Description Dimensions (D x H) 30 (+0.5) mm x 8 (+0.5) mm Design Plastic housing (PA6.6), silicone-free Weight Approx. 6 g Mounting on metal directly on metal without spacing SIMATIC RF600 402 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.8 SIMATIC RF625T 7.8.6.2 Electrical data Characteristic Description Europe USA/Canada Air interface According to ISO 18 000-6 C According to ISO 18 000-6 C Frequency range 865 ... 868 MHz 902 ... 928 MHz 1) Necessary transmit power 2 W (ERP) 4 W (EIRP) Range max. 1.5 m max. 1.5 m Polarization type Linear Linear Energy source Field energy via antenna, without battery Field energy via antenna, without battery Multitag capability yes, minimum distance between data carriers ≥ 50 mm 3) yes, minimum distance between data carriers ≥ 50 mm 3) 2) Reduction of range to about 70% at the band limits 902 MHz or 928 MHz; acquisition is guaranteed at 915 MHz due to frequency hopping procedure. 1) 2) Mounting on a flat metal surface with a diameter of at least 150 mm and at room temperature. The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". When these minimum distances are not reached, there is a reduction in the maximum possible read and write distances of the transponder. 7.8.6.3 7.8.6.4 REVIEW 3) Information on memory Property Description Type EPC Class 1 Gen 2 Memory organization EPC code 96 bits/128 bits User memory 64 bytes TID 96 bits Reserved (passwords) 64 bits Protocol ISO 18000-6C Data retention time 10 years Read cycles Unlimited Write cycles Minimum 100 000, at +22 °C Environmental conditions Property Description Temperature range during operation -25 °C … +85 °C Temperature range during storage -40 °C … +125 °C Shock resistant to EN 60068-2-27 Vibration to EN 60068-2-6 50 g, 1) 20 g, 1) Torsion and bending load Not permissible SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 403 Transponder/tags 7.8 SIMATIC RF625T Property Description Degree of protection IP68 according to EN 60529: (45 minutes. immersion in water; water depth 1 m from top edge of housing at +20 °C) IPx9K to EN 60529: MTBF • Steam blaster nozzle distance 150 mm • 10 ... 15 l water per minute • Pressure 100 bar • Temperature 75 °C • Test time 30 seconds 2 x 10 5 hours The values for shock and vibration are maximum values and must not be applied continuously. 1) 7.8.6.5 Chemical resistance of the RF625T transponder REVIEW The following table provides an overview of the chemical resistance of the data memory made of polyamide 6.6. It must be emphasized that the plastic housing is extremely resistant to chemicals in automobiles (e.g.: oil, grease, diesel fuel, gasoline) which are not listed separately. Substance Concentration Mineral lubricants ■ Aliphatic hydrocarbons ■ Aromatic hydrocarbons ■ Petroleum spirit ■ Weak mineral acids ◪ Strong mineral acids □ Weak organic acids ◪ Strong organic acids □ Oxidizing acids □ Weak alkalis ◪ Strong alkalis □ Trichloroethylene ■ Perchloroethylene ■ Acetone ■ Alcohols ■ Hot water (hydrolysis resistance) ◪ Abbreviations: ■ Resistant ◪ Limited resistance □ Not resistant SIMATIC RF600 404 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.8 SIMATIC RF625T 7.8.7 Certificates and approvals Table 7- 20 SIMATIC RF625T UHF Disk Tag (Europe), 6GT2810-2EE00 Certificate Description Conforms to R&TTE directive Table 7- 21 SIMATIC RF625T UHF Disk Tag (USA/Canada), 6GT2810-2EE01 Standard FCC Federal Communications Commission Passive labels or transponders comply with the valid regulations; certification is not required This product is UL-certified for the USA and Canada. 7.8.8 • UL508 - Industrial Control Equipment • CSA C22.2 No. 142 - Process Control Equipment • UL Report E 120869 Dimension drawing Figure 7-37 REVIEW It meets the following safety standard(s): SIMATIC RF625T UHF Disk Tag Units of measurement: All dimensions in mm SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 405 Transponder/tags 7.9 SIMATIC RF630T 7.9 SIMATIC RF630T 7.9.1 Characteristics The SIMATIC RF630T transponder is a passive (i.e. battery-free) and maintenance-free, cylindrical data carrier. It operates based on the UHF Class 1 Gen 2 technology and is used to save the "Electronic Product Code" (EPC) of 96 bits/240 bits. The transponder also has a 512-bit user memory. Areas of application include the mounting of metallic components (e.g. engine assembly in the automobile industry) as well as RF identification of tools, containers and metal frames. The RF630T is small and rugged and suitable for industrial applications with IP68/IPX9K degree of protection. It is highly resistant to oil, grease and cleaning agents. The SIMATIC RF630T is mounted directly onto metal surfaces to ensure optimum functioning and its typical detection range is 1.2 m. REVIEW SIMATIC RF630T Features Area of application Identification tasks in rugged industrial environments Frequency variants Europe USA/Canada 868 MHz 915 MHz Air interface according to ISO°18000-6C Polarization Linear Memory EPC 96 bit/240 bit Add-on-memory 64 bytes Range 1) max. 1.2 m Mounting for direct mounting on conductive materials (preferably metal). The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) SIMATIC RF600 406 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.9 SIMATIC RF630T 7.9.2 Ordering data Ordering data Article number SIMATIC RF630T (Europe) 6GT2810-2EC00 • For attaching to metal surfaces • Frequency 865 MHz to 868 MHz SIMATIC RF630T (USA / Canada) • For attaching to metal surfaces • Frequency 902 MHz to 928 MHz 6GT2810-2EC10 Planning application 7.9.3.1 Optimum antenna/transponder positioning with plane mounting of the transponder on metal The maximum reading range is achieved when the reader antenna is positioned at right angles to the mounting surface. In the case of parallel mounting directly above the transponder, detection is not possible. Positioning of the RF660A antenna with the RF630R/RF670R/RF680R reader The RF630R, RF670R and RF680R readers can operate with an RF660A antenna which can be positioned as shown. REVIEW 7.9.3 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 407 Transponder/tags 7.9 SIMATIC RF630T REVIEW RF630T application example Figure 7-38 RF630T application example SIMATIC RF600 408 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.9 SIMATIC RF630T Figure 7-39 Example of optimum antenna/transponder positioning Depending on the design of the metal bracket (surface parallel to the transmitting antenna), an angle of 10° will have a favorable effect. REVIEW Positioning of two RF660A antennas Positioning of the RF620R/RF685R reader The RF620R reader with an integrated circular polarized antenna or the RF685R reader can be placed in the same position relative to the RF630T transponder as the RF660A antennas. Please note the different reading ranges for the RF600 readers in the section Electrical data (Page 414) SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 409 Transponder/tags 7.9 SIMATIC RF630T 7.9.3.2 Range when mounted on flat metallic carrier plates REVIEW The transponder generally has linear polarization. The polarization axis runs as shown in the diagram below. If the tag is mounted in the center of a flat metal plate, which is either approximately square or circular, it can be aligned in any direction since the transmitting and receiving RF660A antennas operate with circular polarization. Figure 7-40 Optimum positioning of the transponder on a (square or circular) metal surface Table 7- 22 Range on flat metallic carriers Carrier material Range Metal plate of at least Ø 300 mm 100 % Metal plate Ø 150 mm approx. 75 % Metal plate Ø 120 mm approx. 50 % Metal plate Ø 85 mm approx. 40% On rectangular carrier plates, the range depends on the mounting orientation of the transponder You will find more detailed information on the range in the section "Minimum distances and maximum ranges (Page 344)". 7.9.3.3 Influence of conducting walls on the range If there are conducting walls or restrictions in the vicinity that could affect the wireless field, a distance of approx. 10 cm is recommended. In principle, walls have least influence if the polarization axis is vertical to the conducting wall. SIMATIC RF600 410 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.9 SIMATIC RF630T Range: One conducting wall Influence on range when positioned against one conducting wall View from above 20 mm 50 mm 100 mm Range approx. 40% approx. 40% approx. 90 % Wall height 20 mm approx. 40% approx. 90 % approx. 90 % Wall height 50 mm approx. 40% approx. 40% approx. 90 % Wall height 100 mm REVIEW Distance d Range: Two conducting walls Influence on the range when positioned against two conducting walls Side view Distance d 20 mm 50 mm 100 mm Range approx. 90 % approx. 90 % approx. 90 % Wall height 20 mm approx. 25 % approx. 90 % approx. 90 % Wall height 50 mm approx. 25 % approx. 90 % approx. 90 % Wall height 100 mm The values specified in the tables above are guide values. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 411 Transponder/tags 7.9 SIMATIC RF630T 7.9.3.4 Directional radiation pattern of the transponder Preferably, align the data carrier orthogonal to the transmitting antenna. If, however, the tag including the metallic carrier plate is tilted, the reading range will be reduced. Note Incorrect alignment of the transponder REVIEW When you align the transponder in parallel with the transmitting antenna, it cannot be read! Optimum alignment of the transponder to the Incorrect alignment of the transponder to the transmitting antenna transmitting antenna Rotation about the polarization axis If the transponder mounting surface is circular there is almost no change in the reading range. SIMATIC RF600 412 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.9 SIMATIC RF630T Rotation of the mounting plane Characteristics of the transponder on rotation of the mounting plane 7.9.4 REVIEW Figure 7-41 Mounting instructions Properties Description Type of installation M6 bolt fixing, spanner size 19 mm Tightening torque (at room temperature) ≤ 6 Nm Note Make sure that the mounting surface is even when mounting the transponder. Electrical contact between the mounting surface and the transponder is necessary. Without a metal surface the transponder does not function. 7.9.5 Memory configuration of the transponder The memory configuration of the transponder is described in the section SIMATIC memory configuration of the RF600 transponders and labels (Page 336). SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 413 Transponder/tags 7.9 SIMATIC RF630T 7.9.6 Technical specifications 7.9.6.1 Mechanical data Property Description Dimensions (D x H) 21 mm x 21 mm (without thread), tolerance 1 mm spanner size 19 mm Design Plastic enclosure: PA 6.6 GF, silicone-free Thread: Stainless steel Weight approx. 22 g Installation directly on metal without spacing 7.9.6.2 Electrical data REVIEW Characteristic Description Europe USA/Canada Air interface According to ISO 18 000-6 C According to ISO 18 000-6 C Frequency range 865 ... 868 MHz 902 ... 928 MHz 1) Necessary transmit power 2 W (ERP) 4 W (EIRP) Range max. 1.5 m max. 1.5 m Polarization type Linear Linear Energy source Field energy via antenna, without battery Field energy via antenna, without battery Multitag capability yes, minimum distance between data carriers ≥ 50 mm 3) yes, minimum distance between data carriers ≥ 50 mm 3) 2) Reduction of range to about 70% at the band limits 902 MHz or 928 MHz; detection is guaranteed at 915 MHz due to frequency hopping procedure. 1) Mounting on a flat metal surface with a diameter of at least 300 mm and at room temperature. The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 2) When these minimum distances are not reached, there is a reduction in the maximum possible read and write distances of the transponder. 3) 7.9.6.3 Memory specifications Property Description Type EPC Class 1 Gen 2 Memory organization EPC code 96 bits/240 bits User memory 64 bytes TID 64 bits Reserved (passwords) 64 bits Protocol ISO 18000-6C Data retention time 10 years SIMATIC RF600 414 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.9 SIMATIC RF630T Description Read cycles Unlimited Write cycles Minimum at +22 °C 100 000 Environmental conditions Property Description Temperature range during operation -25 °C to +85 °C Temperature range during storage -40 °C to +125 °C Shock Vibration compliant with EN 60721-3-7 Class 7 M3 100 g, 1) 20 g, 1) Torsion and bending load Not permissible Degree of protection IP68 according to EN 60529: (45 minutes. Immersion in water; water depth 1 m from top edge of enclosure at +20 °C) IPx9K according to DIN 40005-9 (steam jet-air ejector: 150 mm; 10 to 15 l/min; 100 bar; 75 °C) 1) 7.9.6.5 REVIEW 7.9.6.4 Property The values for shock and vibration are maximum values and must not be applied continuously. Chemical resistance of the transponder The following table provides an overview of the chemical resistance of the plastic cap of the transponder made of PA 6.6 GF. Different values apply to the stainless steel bolt head. It must be emphasized that the plastic enclosure is extremely resistant to chemicals in automobiles (e.g.: oil, grease, diesel fuel, gasoline) which are not listed separately. Concentration 20 °C 60 °C conc. 20 Benzol Bleach solution (12.5 % effective chlorine) ᅳ Ammonia, w. Butane, gas, liquid 1) Nothing specified Butyl acetate (acetic acid butyl ester) + 1) Nothing specified Calcium chloride, saturated 10% solution ○ Chlorine ᅳ ᅳ Chrome baths, tech. ᅳ ᅳ Iron salts, w. k. g. Acetic acid, w. 10 ○ ᅳ Ethyl alcohol, w., undenaturated 40 Nothing specified SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 415 Transponder/tags 7.9 SIMATIC RF630T Concentration 20 °C 60 °C 30 Nothing specified Formalin Nothing specified Glycerine Nothing specified Isopropanol ○ Nothing specified + 1) Nothing specified Nothing specified Lactic acid, w. ᅳ Sodium carbonate, w. (soda) Nothing specified Sodium chloride, w. ○ Nothing specified Nothing specified ○ 1) Nothing specified Nothing specified ᅳ Formaldehyde Potassium hydroxide, w. 10-15 % Magnesium salts, w. Methyl alcohol, w. 50 Sodium hydroxide 10 % REVIEW Nitrobenzol Phosphoric acid 10 Propane Nitric acid 10 Hydrochloric acid Sulphur dioxide Sulphuric acid Hydrogen sulphide Carbon tetrachloride 1) 10 ᅳ Low ○ Nothing specified 25 ᅳ 10 ᅳ Dry 1-4 % Nothing specified Nothing specified for stainless steel Abbreviations Resistant ○ Limited resistance ᅳ Not resistant w. Aqueous solution k. g. Cold saturated SIMATIC RF600 416 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.9 SIMATIC RF630T 7.9.7 Certificates and approvals Table 7- 23 6GT2810-2EC00 - RF630T UHF Tool Tag - Europe Certificate Description Conformity with R&TTE directive Table 7- 24 6GT2810-2EC10 - RF630T Gen 2 UHF Tool Tag - USA / Canada Standard FCC Federal Communications Commission Passive labels and transponders comply with the valid regulations; certification is not required. This product is UL-certified for the USA and Canada. 7.9.8 • UL508 - Industrial Control Equipment • CSA C22.2 No. 142 - Process Control Equipment • UL Report E 120869 Dimension drawing Figure 7-42 REVIEW It meets the following safety standard(s): SIMATIC RF630T Units of measurement: All dimensions in mm General tolerances in accordance with DIN ISO 2768f. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 417 Transponder/tags 7.10 SIMATIC RF640T Gen 2 7.10 SIMATIC RF640T Gen 2 7.10.1 Characteristics The SIMATIC RF640T Gen 2 transponder is a passive (i.e. battery-free) and maintenancefree, round-shaped data carrier. It operates based on UHF Class 1 Gen 2 technology and is used to save the electronic product code (EPC) of 96 bits/240 bits. The transponder also has a 512-bit user memory. The areas of application are industrial asset management, RF identification of tools, containers and metallic equipment. The tool tag is small and rugged and suitable for industrial applications with degree of protection IP68. It is highly resistant to oil, grease and cleaning agents. Preferably the SIMATIC RF640T is to be mounted direct on a flat metal surface of at least 150 mm diameter where it achieves a typical sensing distance of 4 m. REVIEW SIMATIC RF640T Gen 2 Features Area of application Identification tasks in rugged industrial environments Suitable for use in hazardous areas. Frequency variants Europe USA/Canada 868 MHz 915 MHz Air interface according to ISO°18000-6C Polarization Linear Memory EPC 96 bit/240 bit Add-on-memory 64 bytes Range 1) max. 4.0 m Mounting for direct mounting on conductive materials (preferably metal). The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) SIMATIC RF600 418 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.10 SIMATIC RF640T Gen 2 Ordering data Ordering data Article number SIMATIC RF640T Gen 2 (Europe) 6GT2810-2DC00 • Frequency 865 MHz to 868 MHz • EPC 96 bits/240 bits • 64-byte user memory • -25 °C to +85 °C operating temperature • Dimensions (D x H) 50 mm x 8 mm SIMATIC RF640T Gen 2 (USA/Canada) • Frequency 902 MHz to 928 MHz • EPC 96 bits/240 bits • 64-byte user memory • -25 °C to +85 °C operating temperature • Dimensions (D x H) 50 mm x 8 mm 6GT2810-2DC10 7.10.3 Planning the use 7.10.3.1 Optimum antenna/transponder positioning with plane mounting of the transponder on metal REVIEW 7.10.2 Example of optimum antenna/transponder positioning Figure 7-43 Example of optimum antenna/transponder positioning with RF600 readers and an RF600 antenna SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 419 Transponder/tags 7.10 SIMATIC RF640T Gen 2 7.10.3.2 Range when mounted on flat metallic carrier plates REVIEW The transponder generally has linear polarization. The polarization axis runs as shown in the diagram below. If the tag is mounted in the center of a flat metal plate, which is either approximately square or circular, it can be aligned in any direction since the transmitting and receiving RF660A antennas operate with circular polarization. Figure 7-44 Optimum positioning of the transponder on a (square or circular) metal surface Table 7- 25 Range on flat metallic carriers Carrier material Range Metal plate of at least Ø 150 mm 100 % Metal plate Ø 120 mm approx. 80% Metal plate Ø 85 mm approx. 55% Metal plate Ø 65 mm approx. 40% On rectangular carrier plates, the range depends on the mounting orientation of the transponder You will find more detailed information on the range in the section "Minimum distances and maximum ranges (Page 344)". SIMATIC RF600 420 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.10 SIMATIC RF640T Gen 2 7.10.3.3 Range when mounted on non-metallic carrier materials The transponder is generally designed for mounting on metallic objects which provide the conditions for the maximum reading ranges Table 7- 26 Range with non-metallic carriers Carrier material Range Transponder on wooden carrier approx. 40% Transponder on plastic carrier approx. 35% Transponder on plastic mineral water bottle approx. 55% Transponder without base approx. 30% The maximum range of 100% is achieved by mounting the transponder in a free space with low reflections on a flat metal carrier with a diameter of at least 150 mm. You will find more detailed information on the range in the section "Minimum distances and maximum ranges (Page 344)". 7.10.3.4 Influence of conducting walls on the range REVIEW If there are conducting walls or restrictions in the vicinity that could affect the wireless field, a distance of approx. 10 cm is recommended. In principle, walls have least influence if the polarization axis is orthogonal to the wall. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 421 Transponder/tags 7.10 SIMATIC RF640T Gen 2 Range: One conducting wall Influence on range when positioned against one conducting wall REVIEW View from above Distance d 20 mm 50 mm 100 mm Range approx. 90 % approx. 90 % approx. 95 % Wall height 20 mm approx. 80% approx. 90 % approx. 90 % Wall height 50 mm approx. 70% approx. 75 % approx. 90 % Wall height 100 mm Range: Two conducting walls Influence on the range when positioned against two conducting walls View from above Side view Distance d 20 mm 50 mm 100 mm Range approx. 75 % approx. 90 % approx. 90 % Wall height 20 mm approx. 50 % approx. 45 % approx. 80% Wall height 50 mm approx. 40% approx. 45 % approx. 75 % Wall height 100 mm The values specified in the tables above are guide values. SIMATIC RF600 422 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.10 SIMATIC RF640T Gen 2 7.10.3.5 Directional radiation pattern of the transponder Preferably, align the tag parallel to the transmitting antenna. If, however, the tag including the metallic carrier plate is tilted, the reading range will be reduced. Figure 7-45 Transponder characteristics when rotated about the polarization axis REVIEW Rotation about the polarization axis SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 423 Transponder/tags 7.10 SIMATIC RF640T Gen 2 Rotation orthogonal to the polarization axis REVIEW Figure 7-46 7.10.3.6 Transponder characteristics when rotated orthogonally to the polarization axis (within the tag plane) Use of the transponder in the Ex protection area TÜV NORD CERT GmbH, appointed center no. 0044 as per Article 9 of the Directive 94/9/EC of the European Council of 23 March 1994, has confirmed the compliance with the essential health and safety requirements relating to the design and construction of equipment and protective systems intended for use in hazardous areas as per Annex II of the Directive. The essential health and safety requirements are satisfied in accordance with standards IEC 60079-0: 2011 and EN 60079-11: 2012. This allows the RF640T transponder to be used in hazardous areas for gases, for the device category 2G and gas group IIC, or alternatively in hazardous areas for dusts, for the device category 2D and group IIIB. Note Readability of the serial number on the type plate When using the transponder, make sure that the serial number can be read. The serial number is lasered and can be hidden by paint or other materials making it illegible. The customer is responsible for making sure that the serial number of a transponder for the hazardous area can be read at all times. SIMATIC RF600 424 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.10 SIMATIC RF640T Gen 2 Identification The identification is as follows: II 2 G Ex ib IIC T6 to T3 GB or Use of the transponder in hazardous areas for gases REVIEW 7.10.3.7 II 2 D Ex ib IIIB T135°C DB Note Transponder labeling The labeling of the front of the transponder shown above is an example and can vary between batches produced at different times. This does not affect the hazardous area marking. Temperature class delineation for gases The temperature class of the transponder for hazardous atmospheres (gases) depends on the ambient temperature and the radiated power of an antenna in the 865 - 868 MHz frequency band within the hazardous area. WARNING Ignitions of gas-air mixtures When using the RF640T transponder, check to ensure that the temperature class is observed in respect of the requirements of the area of application Non-compliance with the permitted temperature ranges while using the transponder can lead to ignitions of gas-air mixtures. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 425 Transponder/tags 7.10 SIMATIC RF640T Gen 2 WARNING Ignitions of gas-air mixtures The maximum transmitting power of the transmitter used to operate the transponder must not exceed 2 W. Non-compliance with the permissible transmitting power can lead to ignitions of gas-air mixtures. Temperature class assignment for gases and a radiated power less than 100 mW ERP REVIEW If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 100 mW, the temperature class assignment is as follows: Ambient temperature range Temperature class -25 °C to +85 °C T5 -25 °C to +76 °C T6 Temperature class assignment for gases and a radiated power less than 500 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 500 mW, the temperature class assignment is as follows: Ambient temperature range Temperature class -25 °C to +85 °C T4 -25 °C to +77 °C T5 -25 °C to +62 °C T6 Temperature class assignment for gases and radiated power for 2000 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 2000 mW, the temperature class assignment is as follows: Ambient temperature range Temperature class -25 °C to +85 °C T3 -25 °C to +65 °C T4 -25 °C to +25 °C T5 -25 °C to +10 °C T6 SIMATIC RF600 426 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.10 SIMATIC RF640T Gen 2 Temperature class assignment for gases and a radiated power of 10 mW to 2000 mW ERP If the radiated power of an antenna radiating into the hazardous area or of an antenna located in the hazardous area in the 865 - 868 MHz frequency band cannot exceed the radiated power selected in the following diagram, the maximum permitted ambient temperature range can be found in the corresponding temperature function of the diagram. This makes the following temperature class assignment valid: Temperature class -25 °C to +85 °C T2 -25 °C to +85 °C T3 -25 °C to Tmax (T4) °C T4 -25 °C to Tmax (T5) °C T5 -25 °C to Tmax (T6) °C T6 REVIEW Ambient temperature range Figure 7-47 7.10.3.8 Maximum permitted ambient temperature depending on the radiated power Use of the transponder in hazardous areas for dusts The equipment is suitable for dusts whose ignition temperatures for a dust layer of 5 mm are higher than 210 °C (smoldering temperature). The ignition temperature specified here according to IEC 60079-0: 2011 for ignition protection type ib in this case references the smoldering temperature of a layer of combustible flyings (ib IIIA) or alternatively nonconductive dusts (ib IIIB). SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 427 Transponder/tags 7.10 SIMATIC RF640T Gen 2 Temperature class delineation for dusts WARNING Ignitions of dust-air mixtures When using the RF640T transponder, check to ensure that the temperature values are complied with in connection with the requirements of the application area. Non-compliance with the permitted temperature ranges while using the transponder can lead to ignitions of dust-air mixtures. Temperature class assignment for dusts and a radiated power less than 100 mW ERP REVIEW If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 100 mW, the temperature class assignment is as follows: Ambient temperature range Temperature value -25 °C ≤ Ta ≤ +85 ℃ T94 °C Temperature class assignment for dusts and a radiated power less than 500 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 500 mW, the temperature class assignment is as follows: Ambient temperature range Temperature value -25 °C ≤ Ta ≤ +85 ℃ T108 °C Temperature class assignment for dusts and a radiated power less than 1280 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 1280 mW, the temperature class assignment is as follows: Ambient temperature range Temperature value -25 °C ≤ Ta ≤ +85 ℃ T135 °C SIMATIC RF600 428 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.10 SIMATIC RF640T Gen 2 Ambient temperature range for dust and radiated power of 2000 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 2000 mW, the temperature class assignment is as follows: Ambient temperature range Temperature value -25 °C ≤ Ta ≤ +60 ℃ T135 °C Temperature class assignment for dusts and a radiated power of 10 mW ERP to 2000 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band can be between the values 10 mW ERP and 1280 mW ERP, the temperature class assignment is as follows: Ambient temperature range Temperature value -25 °C ≤ Ta ≤ +85 ℃ Tvalue °C 1) See diagram, blue line If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band can be between the values 1280 mW ERP and 2000 mW ERP, the temperature class assignment is as follows: Ambient temperature range -25 °C ≤ Ta ≤ Tmax. ambient °C 1) Temperature value 1) 135°C REVIEW 1) See diagram, orange line WARNING Ignitions of dust-air mixtures Using the RF640T transponder with radiant power greater than 1280 mW ERP, requires compliance with the reduced maximum ambient temperature (see diagram) for maintaining the temperature value to a maximum of 135 °C. Non-compliance with the permitted temperature ranges while using the transponder can lead to ignitions of dust-air mixtures. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 429 Transponder/tags 7.10 SIMATIC RF640T Gen 2 The respective temperature value and the maximum allowed ambient temperature in relation to the radiated power of the antenna is shown in the diagram below: REVIEW Temperature value Ambient temperature Figure 7-48 Temperature value and maximum permitted ambient temperature in relation to the radiated power SIMATIC RF600 430 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.10 SIMATIC RF640T Gen 2 7.10.4 Mounting instructions Properties Description Type of installation Screw mounting ①, (M4 screws) (two DIN 433 washers and two M4 hexagon socket head cap screws DIN 6912) Tightening torque (at room temperature) < 1.2 Nm Figure 7-49 Screw mounting REVIEW Note Make sure that the mounting surface is even when mounting the transponder. 7.10.5 Memory configuration of the transponder The memory configuration of the transponder is described in the section SIMATIC memory configuration of the RF600 transponders and labels (Page 336). SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 431 Transponder/tags 7.10 SIMATIC RF640T Gen 2 7.10.6 Technical Specifications 7.10.6.1 Mechanical data Property Description Dimensions (D x H) 50 mm x 8 mm (+1 mm) Design PCB with integrated antenna Design Plastic enclosure (PA12), silicone-free Weight approx. 13 g Mounting on metal directly on metal without spacing 7.10.6.2 Electrical data REVIEW Characteristic Description Europe USA/Canada Air interface According to ISO 18 000-6 C According to ISO 18 000-6 C Frequency range 865 ... 868 MHz 902 ... 928 MHz 1) Necessary transmit power 2 W (ERP) 4 W (EIRP) Range max. 4.0 m max. 4.0 m Polarization type Linear Linear Energy source Field energy via antenna, without battery Field energy via antenna, without battery Multitag capability yes, minimum distance between data carriers ≥ 50 mm 3) yes, minimum distance between data carriers ≥ 50 mm 3) 2) Reduction of range to about 70% at the band limits 902 MHz or 928 MHz; acquisition is guaranteed at 915 MHz due to frequency hopping procedure. 1) 2) Mounting on a flat metal surface with a diameter of at least 150 mm and at room temperature. The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". When these minimum distances are not reached, there is a reduction in the maximum possible read and write distances of the transponder. 3) 7.10.6.3 Memory specifications Property Description Type EPC Class 1 Gen 2 Memory organization EPC code 96 bits/240 bits User memory 64 bytes TID 64 bits Reserved (passwords) 64 bits Protocol ISO 18000-6C Data retention time 10 years SIMATIC RF600 432 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.10 SIMATIC RF640T Gen 2 Description Read cycles Unlimited Write cycles Minimum at +22 °C 100 000 Environmental conditions Property Description Temperature range when operating in nonhazardous areas -25 °C … 85 °C1) Temperature range when operating in areas at risk of a gas explosion with temperature class T3-T6 See alsoUse of the transponder in hazardous areas for gases (Page 425) 2) Temperature range when operating in areas at risk of dust explosions with temperature value ≤ T135 °C See alsoUse of the transponder in hazardous areas for dusts (Page 427) 2) Temperature range during storage -40 °C … 125 °C1) Shock Vibration compliant with EN 60721-3-7 Class 7 M3 100 g, 3) 20 g, 3) Torsion and bending load Not permissible Degree of protection IP68 according to EN 60529: (45 minutes. immersion in water; water depth 1 m from top edge of housing at +20 °C) IP x9K according to EN 60529: • Steam blaster nozzle distance 150 mm • 10 ... 15 l of water per minute • Pressure 100 bar • Temperature 75 °C • Test time 30 seconds REVIEW 7.10.6.4 Property At temperatures above 70 °C the casing may distort slightly; this does not however cause any impairment of function (mechanical or electrical). 1) 2) Directive 94/9/EC of the European Council of 23 March 1994 must be complied with, see also Chapter "Using the transponder in hazardous areas". The values for shock and vibration are maximum values and must not be applied continuously. 3) WARNING Ignitions of gas-air or dust-air mixtures When using the RF640T transponder, check to ensure that the temperature values are observed in respect of the requirements of the hazardous area of application. Non-compliance with the permitted temperature ranges while using the transponder can lead to ignitions of gas-air or dust-air mixtures. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 433 Transponder/tags 7.10 SIMATIC RF640T Gen 2 Note Damage to the surface of the housing The values specified for the IP x9K test are maximum values and must not be applied continuously. Protracted loading of the transponder can lead to damage to the surface of the housing due to high pressures. 7.10.6.5 Chemical resistance of the RF640T transponder The following table gives an overview of the chemical composition of the data memory made from polyamide 12. The plastic housing has a notably high resistance to chemicals used in automobiles (e.g.: oil, grease, diesel fuel, gasoline) which are not listed separately. Concentration Battery acid 30 ○○ ᅳ ○○○○ conc. ○○○○ ○○○○ 10 ○○○○ ○○○○ ○○○○ ○○○ Benzol REVIEW 60 °C ○○○○ Ammonia gas Ammonia, w. 20 °C Bleach solution (12.5 % effective chlorine) ○○ ᅳ Butane, gas, liquid ○○○○ ○○○○ Butyl acetate (acetic acid butyl ester) ○○○○ ○○○○ ○○○○ ○○○ ○○○○ ○○○ Chlorine ᅳ ᅳ Chrome baths, tech. ᅳ ᅳ ○○○○ ○○○○ Calcium chloride, w. Calcium nitrate, w. Iron salts, w. k. g. k. g. Acetic acid, w. 50 ᅳ ᅳ Ethyl alcohol, w., undenaturated 96 ○○○○ ○○○ 50 ○○○○ ○○○○ Formaldehyde, w. 30 ○○○ ᅳ 10 ○○○○ ○○○ Formalin ○○○ ᅳ Glycerine ○○○○ ○○○○ Isopropanol ○○○○ ○○○ ○○○○ ○○○○ ○○ ᅳ k. g. ○○○○ ○○○○ Methyl alcohol, w. 50 ○○○○ ○○○○ Lactic acid, w. 50 ○○ ᅳ Potassium hydroxide, w. 50 Lysol Magnesium salts, w. Sodium carbonate, w. (soda) 10 ○○○ ○○ k. g. ○○○○ ○○○○ SIMATIC RF600 434 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Sodium chloride, w. Concentration 20 °C 60 °C k. g. ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ ○○○○ ○○○ ○○ Sodium hydroxide Nickel salts, w. k. g. Nitrobenzol Phosphoric acid ○ Propane 10 ○○○○ ○○○○ Mercury ○○○○ ○○○○ Nitric acid 10 ○ ᅳ Hydrochloric acid 10 ○ ᅳ Low ○○○○ ○○○○ 25 ○○ ᅳ 10 ○○○ ᅳ Low Sulphur dioxide Sulphuric acid Hydrogen sulphide ○○○○ ○○○○ Carbon tetrachloride ○○○○ ○○○○ Toluene ○○○○ ○○○ Detergent High Plasticizer Abbreviations ○○○○ Resistant ○○○ Virtually resistant ○○ Limited resistance ○ Less resistant ᅳ Not resistant w. Aqueous solution k. g. Cold saturated ○○○○ ○○○○ ○○○○ ○○○○ REVIEW Transponder/tags 7.10 SIMATIC RF640T Gen 2 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 435 Transponder/tags 7.10 SIMATIC RF640T Gen 2 7.10.7 Certificates and approvals Table 7- 27 6GT2810-2DC00 - RF640T Gen 2 UHF Tool Tag - Europe Certificate Description CE approval according to R&TTE guideline For Directive 94/9/EC: EC type test certification no. TÜV 07 ATEX 346241 Recognition of the quality assurance BVS 11 ATEX ZQS/E111 Table 7- 28 6GT2810-2DC10 - RF640T Gen 2 UHF Tool Tag - USA/Canada Standard FCC Federal Communications Commission Passive labels or transponders comply with the valid regulations; certification is not required. This product is UL-certified for the USA and Canada. It meets the following safety standard(s): REVIEW UL 60950-1 - Information Technology Equipment Safety - Part 1: General Requirements CSA C22.2 No. 60950 -1 - Safety of Information Technology Equipment UL Report E 205089 7.10.7.1 EC Declaration of Conformity according to directive 94/9EC RF640T Gen 2 UHF Tool Tag Version 1 The type test certification for the RF640T Gen 2 UHF Tool Tag Version 1 is stored by TÜV 07 ATEX 346241. On the basis of this certification, the CE declaration by the manufacturer has been made according to directive 94/9/EC. The producing factory of the RF640T Gen 2 UHF Tool Tag Version 1 has an ATEX quality assurance system recognized by the DEKRA EXAM GmbH with certificate number BVS 11 ATEX ZQS/E111. Manufacturer's address - distributor Manufacturer's address - factory Siemens Aktiengesellschaft Industry Sector (I) Industry Automation Division (IA) Sensors and Communication (SC) Communication and Identification (CI) Gleiwitzer Str. 555 D-90475 Nürnberg, Germany Siemens Aktiengesellschaft Industry Sector (I) Industry Automation Division (IA) Control Components and System Engineering (CE) Würzburger Straße 121 D-90766 Fürth, Germany SIMATIC RF600 436 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.10 SIMATIC RF640T Gen 2 Dimension drawing REVIEW 7.10.8 Figure 7-50 SIMATIC RF640T Gen 2 UHF Tool Tag Version 1 Units of measurement: All dimensions in mm SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 437 Transponder/tags 7.11 SIMATIC RF680T 7.11 SIMATIC RF680T 7.11.1 Characteristics The heat-resistant SIMATIC RF680T transponder is a passive, maintenance-free data carrier. It operates based on UHF Class 1 Gen 2 technology and is used to save the "Electronic Product Code" (EPC) of 96 bits/240 bits. The transponder also has a 512-bit user memory. These transponders with limited service life are ideally suited to high-temperature applications (e.g. the painting of vehicle bodies) as well as applications in production logistics. The RF680T is rugged and suitable for industrial applications with IP68/IPX9K degree of protection. It is highly resistant to oil, grease and cleaning agents. The SIMATIC RF680T is mounted directly onto metal and non-metal carrier plates to ensure optimum operation and has a typical detection range of 6.7 m. SIMATIC RF680T Features REVIEW Area of application Applications with high temperatures (up to +220 °C). Suitable for use in hazardous areas. Typical application areas: • Paint shops and their preparatory treatments, incl. drying ovens • Electrophoretic deposition area • Primer coat incl. drying oven • Top coat area incl. drying oven • Washing areas at temperatures > 85 °C Frequency range 865 ... 928 MHz (ETSI and FCC) Air interface according to ISO°18000-6C Polarization Linear Temperature range up to 220 °C Memory EPC 96 bit/240 bit Add-on-memory 64 bytes Range 1) max. 7 m Mounting Suitable for direct mounting on conductive and non-conductive materials. Material Plastic PPS; silicone-free Dimensions 130 x 32 x 15 mm The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 1) SIMATIC RF600 438 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.11 SIMATIC RF680T 7.11.2 Ordering data Ordering data Article number SIMATIC RF680T 6GT2810-2HG80 • Frequency 865 MHz to 928 MHz • EPC 96 bit/240 bit (64 bytes user memory) • -25 ... +220 °C • 130 x 32 x 15 mm Planning the use 7.11.3.1 Optimum antenna/transponder positioning with plane mounting of the transponder on metal REVIEW 7.11.3 Figure 7-51 Example of optimum antenna/transponder positioning SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 439 Transponder/tags 7.11 SIMATIC RF680T 7.11.3.2 Range when mounted on flat metallic carrier plates REVIEW The transponder generally has linear polarization. The polarization axis runs as shown in the diagram below. If the transponder is centrally mounted on a plane metal plate, which may either be almost square or circular, it can be aligned in any direction if the transmitting and receiving antennas operate with circular polarization (such as RF660A and RF620R). Figure 7-52 Optimum positioning of the transponder on a (square or circular) metal surface Table 7- 29 Range on flat metallic carriers Carrier material Range Europe Range USA Metal plate 150 x 150 mm typically 50 % typically 50 % Metal plate 300 x 300 mm typically 100 % typically 100 % On rectangular carrier plates, the range depends on the mounting orientation of the transponder A 90° rotation of the transponder about the axis of symmetry may result in greater ranges. You will find more detailed information on the range in the section "Minimum distances and maximum ranges (Page 344)". SIMATIC RF600 440 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.11 SIMATIC RF680T 7.11.3.3 Influence of conducting walls on the range If there are conducting walls or restrictions in the vicinity that shade the radio field, a distance of approx. 10 cm is recommended between the transponder and the wall. In principle, walls have least influence if the polarization axis is orthogonal to the wall. Range: One conducting wall Influence on the range when positioned orthogonally to the conducting wall Distance d 20 mm 50 mm 100 mm Range approx. 100% approx. 100% approx. 100% Wall height 20 mm approx. 100% approx. 100% approx. 100% Wall height 50 mm approx. 80% approx. 100% approx. 100% Wall height 100 mm REVIEW View from above SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 441 Transponder/tags 7.11 SIMATIC RF680T Influence on the range when positioned parallel to the conducting wall View from above Distance d 20 mm 50 mm 100 mm Range approx. 50% approx. 70% approx. 90% Wall height 20 mm approx. 40% approx. 70% approx. 90% Wall height 50 mm approx. 30% approx. 50% approx. 90% Wall height 100 mm REVIEW Range: Two conducting walls Influence on the range when positioned against two conducting walls Side view Distance d 20 mm 50 mm 100 mm Range approx. 50% approx. 70% approx. 90% Wall height 20 mm approx. 30% approx. 60% approx. 90% Wall height 50 mm approx. 25% approx. 50% approx. 90% Wall height 100 mm The values specified in the tables above are guide values. SIMATIC RF600 442 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.11 SIMATIC RF680T 7.11.3.4 Directional radiation pattern of the transponder on metallic surfaces It is recommendable to align the transponder parallel to the transmitting antenna. If, however, the transponder including the metallic carrier plate is tilted, the reading range will be reduced. REVIEW Rotation about the polarization axis or orthogonal to the polarization axis Figure 7-53 Characteristic of the transponder when rotated about the polarization axis or orthogonally to the polarization axis Note Please note that the directional effect is dependent on the size of the metal surface. The larger the metal surface, the larger the directional effect. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 443 Transponder/tags 7.11 SIMATIC RF680T 7.11.3.5 Range when mounted on non-metallic carrier materials The RF680T transponder is a universal transponder for mounting on many different types of carrier materials. Table 7- 30 Range for non-metal carriers (RF670R = 2 W ERP;) Carrier material Range Transponder on wooden carrier (dry, degree of moisture < 15%) typically 50 % Transponder on plastic carrier typically 50 % Transponder on glass typically 50 % The maximum range of 100% is achieved by mounting the transponder in a free space with low reflections on a flat metal carrier with a diameter of at least 300 mm. You will find more detailed information on the range in the section "Minimum distances and maximum ranges (Page 344)". REVIEW 7.11.3.6 Directional radiation pattern of the transponder on non-metallic surfaces It is recommendable to align the transponder parallel to the transmitting antenna. If, however, the transponder including the metallic carrier plate is tilted, the reading range will be reduced. Rotation about the polarization axis Figure 7-54 Rotation of the transponder about the polarization axis Generally the range does not change when the transponder without carrier material is rotated about the polarization axis. SIMATIC RF600 444 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.11 SIMATIC RF680T REVIEW Rotation orthogonal to the polarization axis Figure 7-55 Transponder characteristics when rotated orthogonally to the polarization axis (within the tag plane) If the transponder is positioned orthogonally to the transmitting antenna, it normally cannot be read. Therefore the transponder is preferably to be aligned parallel to the transmitting antenna. The following figure illustrates this situation. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 445 Transponder/tags 7.11 SIMATIC RF680T REVIEW Figure 7-56 7.11.3.7 Application example Relationship between performance and reading range The absolute values of the reading ranges specified below refer to a transmit power of 2 W ERP. When the power is reduced (e.g. when a different reader is used), you will find the corresponding reduced reading ranges in the following table: SIMATIC RF600 446 System Manual, xx/2014, J31069-D0171-U001-A15-7618 REVIEW Transponder/tags 7.11 SIMATIC RF680T 7.11.3.8 Use of the transponder in hazardous areas TÜV NORD CERT GmbH, appointed center no. 0044 as per Article 9 of the Directive 94/9/EC of the European Council of 23 March 1994, has confirmed the compliance with the essential health and safety requirements relating to the design and construction of equipment and protective systems intended for use in hazardous areas as per Annex II of the Directive. The essential health and safety requirements are satisfied in accordance with standards IEC 60079-0:2011 and EN 60079-11:2012. This allows the RF680T transponder to be used in hazardous areas for gases, for the device category 2G and gas group IIB, or alternatively in hazardous areas for dusts, for the device category 2D and group IIIB. Note Readability of the serial number on the type plate When using the transponder, make sure that the serial number can be read. The serial number is lasered and can be hidden by paint or other materials making it illegible. The customer is responsible for making sure that the serial number of a transponder for the hazardous area can be read at all times. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 447 Transponder/tags 7.11 SIMATIC RF680T Identification The identification is as follows: II 2G Ex ib IIB T6 to T2 Gb or 7.11.3.9 II 2D Ex ib IIIB T135 °C Db Use of the transponder in hazardous areas for gases Note REVIEW Transponder labeling The labeling of the front of the transponder shown above is an example and can vary between batches produced at different times. This does not affect the hazardous area marking. Temperature class delineation for gases The temperature class of the transponder for hazardous atmospheres (gases) depends on the ambient temperature and the radiated power of an antenna in the 865 - 868 MHz frequency band within the hazardous area. WARNING Ignitions of gas-air mixtures When using the RF680T transponder, check to make sure that the temperature class is adhered to in keeping with the requirements of the area of application Non-compliance with the permitted temperature ranges while using the transponder can lead to ignitions of gasair mixtures. SIMATIC RF600 448 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.11 SIMATIC RF680T WARNING Ignitions of gas-air mixtures The maximum transmitting power of the transmitter used to operate the transponder must not exceed 2 W. Non-compliance with the permissible transmitting power can lead to ignitions of gas-air mixtures. Temperature class assignment for gases and a radiated power less than 100 mW ERP Ambient temperature range Temperature class -25 °C ... +200 °C T2 -25 °C ... +190 °C T3 -25 °C ... +125 °C T4 -25 °C ... +90 °C T5 -25 °C ... +75 °C T6 Temperature class assignment for gases and a radiated power less than 500 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 500 mW, the temperature class assignment is as follows: Ambient temperature range Temperature class -25 °C ... +220 °C T2 -25 °C ... +173 °C T3 -25 °C ... +108 °C T4 -25 °C ... +73 °C T5 -25 °C ... +58 °C T6 REVIEW If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 100 mW, the temperature class assignment is as follows: SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 449 Transponder/tags 7.11 SIMATIC RF680T Temperature class assignment for gases and radiated power for 1000 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 1000 mW, the temperature class assignment is as follows: Ambient temperature range Temperature class -25 °C ... +220 °C T2 -25 °C ... +151 °C T3 -25 °C ... +86 °C T4 -25 °C ... +51 °C T5 -25 °C ... +36 °C T6 Temperature class assignment for gases and radiated power for 2000 mW ERP REVIEW If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 2000 mW, the temperature class assignment is as follows: Ambient temperature range Temperature class -25 °C ... +208 °C T2 -25 °C ... +108 °C T3 -25 °C ... +43 °C T4 -25 °C ... +8 °C T5 Temperature class assignment for gases and a radiated power of 10 mW to 2000 mW ERP If the radiated power of an antenna radiating into the hazardous area or of an antenna located in the hazardous area in the 865 - 868 MHz frequency band cannot exceed the radiated power selected in the following diagram, the maximum permitted ambient temperature range can be found in the corresponding temperature function of the diagram. This makes the following temperature class assignment valid: Ambient temperature range Temperature class -25 °C ... Tmax (T2) °C T2 -25 °C ... Tmax (T3) °C T3 -25 °C ... Tmax (T4) °C T4 -25 °C ... Tmax (T5) °C T5 -25 °C ... Tmax (T6) °C T6 SIMATIC RF600 450 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.11 SIMATIC RF680T Maximum permitted ambient temperature depending on the radiated power 7.11.3.10 REVIEW Figure 7-57 Use of the transponder in hazardous areas for dusts The equipment is suitable for dusts whose ignition temperatures for a dust layer of 5 mm are higher than 210 °C (smoldering temperature). The ignition temperature specified here according to IEC 60079-0:2011 for ignition protection type ib in this case references the smoldering temperature of a layer of combustible flyings (ib IIIA) or alternatively nonconductive dusts (ib IIIB). Temperature class delineation for dusts WARNING Ignitions of dust-air mixtures When using the RF680T transponder, check to make sure that the temperature values are adhered to in keeping with the requirements of the area of application Non-compliance with the permitted temperature ranges while using the transponder can lead to ignitions of dustair mixtures. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 451 Transponder/tags 7.11 SIMATIC RF680T Temperature class assignment for dusts and a radiated power less than 100 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 100 mW, the temperature class assignment is as follows: Ambient temperature range Temperature value -25 °C ≤ Ta ≤ +125 ℃ T135 °C Temperature class assignment for dusts and a radiated power less than 500 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 500 mW, the temperature class assignment is as follows: Ambient temperature range Temperature value -25 °C ≤ Ta ≤ +108 ℃ T135 °C Temperature class assignment for dusts and a radiated power less than 1000 mW ERP REVIEW If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 1000 mW, the temperature class assignment is as follows: Ambient temperature range Temperature value -25 °C ≤ Ta ≤ +86 ℃ T135 °C Ambient temperature range for dust and radiated power of 2000 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band cannot exceed the value 2000 mW, the temperature class assignment is as follows: Ambient temperature range Temperature value -25 °C ≤ Ta ≤ +43 ℃ T135 °C SIMATIC RF600 452 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.11 SIMATIC RF680T Temperature class assignment for dusts and a radiated power of 10 mW ERP to 2000 mW ERP If the radiated power of an antenna radiating into the hazardous area or located in the hazardous area and operating in the 865 - 868 MHz frequency band can be between the values 10 mW ERP and 2000 mW ERP, the temperature class assignment is as follows: Ambient temperature range -25 °C ≤ Ta ≤ Tmax. ambient °C 1) See diagram, orange line 2) See diagram, blue line Temperature value 1) 135°C 2) WARNING Ignitions of dust-air mixtures Using the RF680T transponder with radiant power greater than 1280 mW ERP, requires compliance with the reduced maximum ambient temperature (see diagram) for maintaining the temperature value to a maximum of 135 °C. Non-compliance with the permitted temperature ranges while using the transponder can lead to ignitions of dust-air mixtures. REVIEW The respective temperature value and the maximum allowed ambient temperature in relation to the radiated power of the antenna is shown in the diagram below: Temperature value Ambient temperature Figure 7-58 Temperature value and maximum permitted ambient temperature in relation to the radiated power SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 453 Transponder/tags 7.11 SIMATIC RF680T 7.11.4 Mounting instructions REVIEW Mount the SIMATIC RF680T transponder on the base using two M6 screws. Figure 7-59 Mounting SIMATIC RF680T Properties Description Type of mounting M6 screw mounting Tightening torque (at room temperature) ≤ 1 Nm (Note the expansion coefficients of the materials used at high temperatures!) Note Reduction of the read/write distance When mounting on metal or conductive material, ensure that the space below the transponder remains empty. 7.11.5 Memory configuration of the transponder The memory configuration of the transponder is described in the section SIMATIC memory configuration of the RF600 transponders and labels (Page 336). SIMATIC RF600 454 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.11 SIMATIC RF680T 7.11.6 Technical specifications 7.11.6.1 Mechanical data Property Description Dimensions (L x W x H) 130 x 32 x 15 mm Design Plastic housing (PPS) Housing color Black Weight Approx. 50 g Mounting on metal Yes Electrical data Characteristic Description Europe USA/Canada Air interface According to ISO 18 000-6 C Frequency range 865 ... 868 MHz 915 ... 928 MHz 1) Necessary transmit power 2 W (ERP) 4 W (EIRP) Range 2) max. 7 m Polarization type Linear Energy source Magnetic energy via antenna, without battery Multitag capability yes, minimum distance between data carriers ≥ 50 mm 3) REVIEW 7.11.6.2 Reduction of range to about 70% at the band limit 928 MHz on metal surfaces; acquisition is guaranteed at 921 MHz due to the frequency hopping procedure. 1) Mounting on a flat metal surface with a diameter of at least 300 mm and at room temperature. The information relates to the maximum read range. You will find more information on ranges in the section "Minimum distances and maximum ranges (Page 344)". 2) When these minimum distances are not reached, there is a reduction in the maximum possible read and write distances of the transponder. 3) 7.11.6.3 Memory specifications Property Description Type EPC Class 1 Gen2 Memory organization 96 bits/240 bits EPC code User memory 64 bytes Protocol ISO 18000-6C Data retention time 10 years Read cycles Unlimited Write cycles Typ. 1 000 000 (at +40 °C) SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 455 Transponder/tags 7.11 SIMATIC RF680T 7.11.6.4 Environmental conditions Property Ambient temperature Description • REVIEW • Operation Transport and storage -25 °C ... +100 °C Permanent from 100 °C ... +140 °C 20% reduction in the limit distance +200 °C 2) Tested up to 5000 hours or 3000 cycles +220 °C Tested up to 2000 hours or 1500 cycles Temperature range when operating in areas at risk of a gas explosion with temperature class T2-T6 See also Use of the transponder in hazardous areas for gases (Page 448) 3) Temperature range when operating in areas at risk of dust explosions with T135 °C See also Use of the transponder in hazardous areas for dusts (Page 451) 3) -40 °C ... +100 °C Shock Vibration compliant with EN 60721-3-7 Class 7 M3 50 g, 1) 20 g 1) Torsion and bending load Not permissible Degree of protection • IP68 according to EN 60529: (60 minutes. Immersion in cleaning fluids, fluid depth 5 m top edge of housing) • Dipping lacquer • IPx9K (steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75 °C) Silicone-free Yes MTBF 1,6 · 107 h The values for shock and vibration are maximum values and must not be applied continuously. 1) 2) Note that no processing is possible at temperatures of +140 °C or higher. Directive 94/9/EC of the European Council of 23 March 1994 must be complied with, see also Chapter "Using the transponder in hazardous areas (Page 447)". 3) SIMATIC RF600 456 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.11 SIMATIC RF680T 7.11.6.5 Chemical resistance of the RF680T transponder 20 °C 65 °C Ammonia, w. conc. ○ Butane gas Butyl acetate (acetic acid butyl ester) Calcium chloride Chlorine Chrome baths, tech. Acetic acid, w. 10% Ethyl alcohol, w., undenaturated Formaldehyde Isopropanol Methyl alcohol Lactic acid, w. Sodium carbonate, w. (soda) Sodium chloride, w. Sodium hydroxide 10% Nitrobenzol ○ Phosphoric acid Propane Nitric acid 10% Hydrochloric acid 10% Sulfur dioxide, minimal Sulfuric acid 25% Hydrogen sulfide, dry Carbon tetrachloride ○ REVIEW The following table provides an overview of the chemical resistance of the data memory made of polypropylene sulfide. Abbreviations Resistant ○ Limited resistance ᅳ Not resistant SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 457 Transponder/tags 7.11 SIMATIC RF680T 7.11.7 Certificates and approvals Table 7- 31 6GT2810-2HG80 - RF680T - Europe Certificate Description Conformity with R&TTE directive For Directive 94/9/EC: EC type test certification no. TÜV 07 ATEX 346241 Recognition of the quality assurance BVS 11 ATEX ZQS/E111 Table 7- 32 6GT2810-2HG80- RF680T - USA / Canada Standard FCC Federal Communications Commission Passive labels or transponders comply with the valid regulations; certification is not required. This product is UL-certified for the USA and Canada. REVIEW It meets the following safety standard(s): 7.11.7.1 • UL508 - Industrial Control Equipment • CSA C22.2 No. 142 - Process Control Equipment • UL Report E 120869 EC Declaration of Conformity according to directive 94/9/EG RF680T Version 1 The type test certification for the RF680T Version 1 is stored by TÜV 07 ATEX 346241. On the basis of this certification, the CE declaration by the manufacturer has been made according to directive 94/9/EC. The producing factory of the RF680T Version 1 has an ATEX quality assurance system recognized by the DEKRA EXAM GmbH with certificate number BVS 11 ATEX ZQS/E111. Manufacturer's address - distributor Manufacturer's address - factory Siemens Aktiengesellschaft Industry Sector (I) Industry Automation Division (IA) Sensors and Communication (SC) Communication and Identification (CI) Gleiwitzer Str. 555 D-90475 Nürnberg, Germany Siemens Aktiengesellschaft Industry Sector (I) Industry Automation Division (IA) Control Components and System Engineering (CE) Würzburger Straße 121 D-90766 Fürth, Germany SIMATIC RF600 458 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Transponder/tags 7.11 SIMATIC RF680T 7.11.8 Dimension drawing Figure 7-60 Dimension drawing of SIMATIC RF680T Units of measurement: All dimensions in mm REVIEW Tolerances, unless indicated otherwise, are +-0.5 mm. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 459 REVIEW Transponder/tags 7.11 SIMATIC RF680T SIMATIC RF600 460 System Manual, xx/2014, J31069-D0171-U001-A15-7618 8 Integration into networks 8.1 Overview of parameterization of RF600 reader Reader SIMATIC command messages RF-MANAGER Basic XML commands RFID reader interface RF620R/ RF630R: "Configuration Manual RF620R/RF630R", chapter "Overview of commands" RF640R/ RF670R Online help > chapter "Working with RFID objects" SIMATIC RF Function Manual, Chapter "Standard Configuration Messages" RF650R/ RF680R/ RF685R "Configuration manual RF650R/RF680R/RF685 R" section "Interface to the SIMATIC controller" "Configuration manual RF650R/RF680R/RF685 R" section "XML interface" RF680M Function Manual Mobile Reader, section "RFID Reader Interface Reference" 8.2 REVIEW The parameter assignment possibilities that are available to you for each reader of the RF600 family are outlined below. You will find detailed information on parameter assignment in the specified chapters of the documentation: Integration in IT networks via the user application Connecting the readers RF640R/RF670R using XML If you want to create your own applications for the RF640R/RF670R reader, you can do this using the XML-based interface of the reader. For information about XML commands, refer to the "SIMATIC RF Function Manual" . Connecting the readers RF650R/RF680R/RF685R using XML If you want to create your own applications for the RF650R/RF680R/RF685R reader, you can do this using the XML-based demo application of the reader. You will find information on the XML commands in the configuration manual "SIMATIC RF650R/RF680R/RF685R". SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 461 Integration into networks 8.3 Integration in SIMATIC networks 8.3 Integration in SIMATIC networks Connecting the readers RF620R/RF630R RF620R and RF630R readers are connected to the SIMATIC controller via the following communications modules: ● SIMATIC RF170C ● SIMATIC RF180C ● ASM 456 ● ASM 475 The RF182C communications module is connected with the PC directly over Ethernet. Connecting the RF680R/RF685R readers The RF680R/RF685R readers can be connected to a SIMATIC controller via PROFINET. Note Connection to the SIMATIC network planned REVIEW A connection via the ASM 456 and RF180C communications modules is currently being planned. This connection allows operation of the devices via PROFINET and PROFIBUS. With the help of the communications modules, the readers can also be connected in series. Options for connecting via communications modules Table 8- 1 Function blocks Option for connecting the readers via communications modules Communications modules ASM 456 RF170C RF180C ASM 475 1) RF182C 2) RF160C 1) 2) FB 45 1 - 2 readers FB 55 1 - 2 readers 1 - 2 readers 1 - 2 readers 1 - 2 readers N/A N/A N/A 1 - 2 readers 1 - 2 readers 1 - 2 readers N/A N/A N/A XML FC 44 N/A N/A N/A N/A 1 - 2 readers N/A N/A N/A N/A N/A N/A N/A 1 - 2 readers N/A Ethernet/IP N/A N/A N/A N/A N/A N/A 1) RFID 181EIP 2) 1 - 2 readers With all possible combinations, the input voltage at the communications module must not be below 21.6 V. The CMs/ASMs may only be operated in an ambient temperature of maximum 55 °C. 1) If 2 readers are used with a CM/ASM, the CM/ASM may only be operated at a maximum ambient temperature of 35 ℃. 2) The communications modules do not currently support multitag operation. SIMATIC RF600 462 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Integration into networks 8.3 Integration in SIMATIC networks Communications modules and function blocks Table 8- 2 Properties of the communications modules ASM/CM Interfaces to the application (PLC) ASM 456 Interfaces to the reader Function blocks Reader connections Dimensions (W x H x D) in mm Temperature Degree range of protecti on PROFIBUS DP-V1 2 x 8-pin FB 45 connection socket, FC 55 M12 2 (parallel) 60 x 210 x 54 0 ... +55 °C IP67 SIMATIC RF170C PROFIBUS DP-V1 2 x 8-pin FB 45 FC 55 connection socket, PROFINET IO M12 2 (parallel) 90 x 130 x 60 -25 ... 55° C IP67 SIMATIC RF180C PROFINET IO 2 x 8-pin FB 45 connection socket, M12 2 (parallel) 60 x 210 54 0 ... +60° C IP67 SIMATIC RF182C TCP/IP 2 x 8-pin connection socket, M12 2 (parallel) 60 x 210 x 54 0 ... +60° C IP67 or 79 REVIEW The following configuration graphics show which readers can be connected to which interface modules/communications modules. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 463 Integration into networks 8.3 Integration in SIMATIC networks REVIEW Configuration with SIMATIC RF170C Figure 8-1 Configuration with SIMATIC RF170C For more detailed information, refer to SIMATIC RF170C Operating Instructions (http://support.automation.siemens.com/WW/view/en/32622825). SIMATIC RF600 464 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Integration into networks 8.3 Integration in SIMATIC networks REVIEW Configuration with SIMATIC RF180C Figure 8-2 Configuration with SIMATIC RF180C For more detailed information, refer to SIMATIC RF180C Operating Instructions (http://support.automation.siemens.com/WW/view/en/30012157). SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 465 Integration into networks 8.3 Integration in SIMATIC networks REVIEW Configuration with ASM 456 Figure 8-3 Configuration with ASM 456 For more detailed information, refer to ASM 456 Operating Instructions (http://support.automation.siemens.com/WW/view/en/32629442). SIMATIC RF600 466 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Integration into networks 8.3 Integration in SIMATIC networks Figure 8-4 Configuration with SIMATIC RF182C For more detailed information, see SIMATIC RF182C Operating Instructions (http://support.automation.siemens.com/WW/view/en/38507897) REVIEW Configuration with RF182C SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 467 REVIEW Integration into networks 8.3 Integration in SIMATIC networks SIMATIC RF600 468 System Manual, xx/2014, J31069-D0171-U001-A15-7618 9 System diagnostics 9.1 Error messages and flash codes for RF620R/RF630R error_MOBY The ERR LED of the reader flashes when there are error messages. Some errors are also indicated by the flashing ERR LED of the CM. Table 9- 1 Error code Error messages of the communications module via the "error_MOBY" variable (B#16#..) Flashing of ERR LED 00 – Description No error 01 1x Boot message 2x Presence error, possible causes: • The active command was not carried out completely • The transponder left the field while the command was being processed • Communication problem between reader and transponder The next command is automatically executed on the next transponder. A read or write command is possible. REVIEW Default value if everything is ok If the write command is aborted with error code 01, inconsistencies between the expected and actual data may occur on the data carrier. Repeat the read/write command. 03 3x Problem on the connection to the reader or antenna problem. • The cable between the communications module and reader is wired incorrectly or there is a cable break • Antenna error: (Cable is defective), cable is no longer connected • The 24 V supply voltage is not connected or is not on or has failed briefly • Automatic fuse on the CM has blown • Hardware defect • Another reader is in the vicinity and is active • Interference on reader - or PROFIBUS line • Execute "init_run" after eliminating the problem SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 469 System diagnostics 9.1 Error messages and flash codes for RF620R/RF630R Error code (B#16#..) Flashing of ERR LED 05 5x Description Command/parameter assignment error, possible causes: • Unknown command • Incorrect parameter • Function not allowed • Mode in "SET-ANT" command unknown FB 45 / FB 55 is sending an uninterpretable command to the communications module. 06 6x • "command_DB" contains invalid command parameters • The "command_DB" was overwritten by the user • The transponder has signaled an address error Field disturbance on reader REVIEW The reader is receiving interference pulses from the environment. • The distance between two readers is too small and does not correspond to the configuration guidelines • The connecting cable to the reader is defective or too long or does not comply with the specification 07 7x No free ETSI transmit channel 09 9x Wrong communications standard selected in the "init_run" command (e.g. FCC for ETSI reader) 0B 11x Transponder memory cannot be read correctly or cannot be written to. The transponder signals an error. Options for troubleshooting: 0C 0D 0E 12x 13x 14x • Increase power • Change antenna alignment • Avoid field interference Memory of the transponder cannot be written to • Transponder memory is defective • Memory is write-protected (Memory Locked: 000000100B) (The transponder memory is PERMA-locked and cannot be overwritten or the reader password has to be reset) Error in specified address (address error) • The specified address does not exist on the transponder • The command must be checked and corrected. • This is not the correct transponder type. • Access attempted to non-existent or non-accessible memory areas ( Memoryoverrun: 00000011B) Password error • Incorrect transponder password (the reader password must be set again so that it matches the password). SIMATIC RF600 470 System Manual, xx/2014, J31069-D0171-U001-A15-7618 System diagnostics 9.1 Error messages and flash codes for RF620R/RF630R Error code (B#16#..) Flashing of ERR LED 0F 1x 10 16x Description Start-up message from CM. The CM was off and has not yet received an "init_run" command • "init_run" needs to be executed • The same physical CM channel is used in two (or more) UDT 10 structures. Check "ASM_address" and "ASM_channel" in all UDT 10 structures. "NEXT" not possible or not permitted • CM is operating without MDS control ("MDS_control = 0,1") • CM has already received a "NEXT" command • CM/reader does not recognize a "NEXT" command "REPEAT" after forbidden commands: 12 – 18x "REPEAT" for "SET-ANT" • "REPEAT" for "SLG-STATUS" Short circuit or overload of the 24 V outputs (DQ, error code, presence) • The affected output is turned off • All outputs are turned off when total overload occurs • A reset can only be performed by turning the 24 V voltage off and on again • Then start "init_run" Internal CM communication error. • Connector contact problem on the CM • Defective CM hardware – 13 14 19x 20x REVIEW 11 • Return CM for repair • Start the "init_run" command after eliminating the problem • CM/reader does not have enough buffer space to store the command temporarily. • Maximum allowable number of 150 commands in a command chain was ignored. If "REPEAT" is used in conjunction with a command chain, the maximum number of commands is also 150 (including the number of commands from a command repetition). If a command chain contains more than 150 commands, after the 150th command is called, it will be stopped and the above error message will be sent without processing the complete chain. Commands in the command chain that have already been executed can still be sent later after the error message "0x13" is sent. Internal CM/reader error. • Program sequence error on the CM • Cycle power to the CM • Start the "init_run" command after eliminating the problem • Watchdog error on reader SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 471 System diagnostics 9.1 Error messages and flash codes for RF620R/RF630R Error code (B#16#..) Flashing of ERR LED 15 21x Description Bad parameter assignment of the CM/reader • 16 23x REVIEW 17 22x 18 19 – 25x Check INPUT parameters in UDT 10 • Check parameters in HW Config • Transmit power set too high • Unused parameter bits are not 0. • "init_run" command has incorrect parameters • After a start-up, the CM has still not received an "init_run". • "scanning_time = 0x00" parameter was set (no standard selected). The FB command cannot be executed with the CM parameter assignment on PROFIBUS. • Length of the input/output areas too small for the cyclic I/O word. Did you use the right GSD file? • FB command (e.g. read) has too much user data (data length > 233 bytes) Communication error between FB 45 / FB 55 and communications module. Handshake error • "Params_DB" (UDT 10) of this CM station is overwritten by other parts of the program • Check parameter assignment of communications module in UDT 10 • Check FB 45/FB 55 command that caused this error • Start the "init_run" command after eliminating the problem An error has occurred that must be acknowledged with an "init_run". • A temporary short circuit has occurred on PROFIBUS • The "init_run" command is incorrect • Start the "init_run" command after eliminating the problem • Check the parameters "ASM_address", "ASM_channel" and "MOBY_mode". Previous command is active or buffer overflow The user sent a new command to the CM although the last command was still active. • Active command can only be terminated with an "init_run" • Before a new command can be started "READY-Bit = 1 must be set; exception: "init_run" • Two FB 45/FC 55 calls were set with the same "ASM_address" and "ASM_channel" parameters • Two FB 45/FC 55 calls are using the same "Params_DB" pointer • Start the "init_run" command after eliminating the problem • When command repetition (e.g. read-only MDS) is used, no data is fetched from the transponder. The data buffer on the CM has overflowed. Transponder data has been lost. SIMATIC RF600 472 System Manual, xx/2014, J31069-D0171-U001-A15-7618 System diagnostics 9.1 Error messages and flash codes for RF620R/RF630R Error code (B#16#..) Flashing of ERR LED 1A – Description PROFIBUS DP error occurred. • The PROFIBUS DP bus connection was interrupted – Wire break on the bus – Bus connector on CM was removed briefly • PROFIBUS DP master does not address CM anymore • "init_run" needs to be executed The CM has detected a frame interruption on the bus. PROFIBUS may have been reconfigured (e.g. with HW Config). This error is only indicated when access monitoring has been enabled in the PROFIBUS configuration. • 1C 1D 27x 28x – There is an inconsistency in the parameter assignment of the reader. Parameters were probably set in the Advanced User Parameter parameter with which the reader cannot work. • ETSI performance testing faulty • Antenna is already switched off • Antenna is already switched on • Mode in "SET-ANT" unknown. More transponders are located in the antenna field than can be processed simultaneously by the reader. A read or write command was sent to a transponder (UID) and one of the following conditions was met at the same time: • REVIEW 1B Only 1 transponder at a time can be processed with FB 45. With FB 45 and FB 55: there is more than one transponder with the same EPC-ID in the antenna field of the reader. Countermeasures: • • with FB 55: Increase the value in multitag or decrease the number of transponders in the field. • with FB 55 (with MOBY_mode = 7): There is one or more transponder in the antenna field for which the content of the "FF00 – FF03" addresses of the EPC-ID does not match (uniqueness when accessing transponders using a UID with the length of 8 bytes). • Power supply of the transponder in the limit range: Due to short-term power shortage, a transponder loses its communication status (session) and the identical EPC-ID is sent a second time as soon as power is above the limit value again. Increase the reader's radiated power and/or reduce the distance between antenna and transponder until this effect no longer occurs. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 473 System diagnostics 9.1 Error messages and flash codes for RF620R/RF630R Error code *) (B#16#..) Flashing of ERR LED Description 1E 30x Wrong number of characters in the command message frame. 1F 31 Active command canceled by "RESET ("init_run" or "cancel") or bus connector removed • Communication with the transponder was aborted by "init_run" • This error can only be reported if there is an "init_run" or "cancel" You will find the meaning of the error numbers in the EPC Global Class 1 Gen 2 document, Annex I. error_FB Table 9- 2 Error variable "error_FB" Error code Description REVIEW (B#16#...) 00 No error; default value if everything is ok 01 "Params_DB" is not available in SIMATIC 02 "Params_DB" is too small • UDT 10/11 was not used during definition • "Params_DB" must be 300 bytes in length (for each channel) • "Params_DB", "Params_ADDR" - check that they are correct 03 The DB after the "command_DB_number" pointer is not available in the SIMATIC controller. 04 The "command_DB" on the SIMATIC controller is too small 05 • UDT 20/21 was not used during command definition • The last command in the "command_DB" is a chained command; reset the chaining bit • Check the "command_DB_number/command_DB_address" command pointer Invalid command type • Check the "command_DB_number/command_DB_address" command pointer • Check the actual values in the "command_DB" – "init_run" needs to be executed SIMATIC RF600 474 System Manual, xx/2014, J31069-D0171-U001-A15-7618 System diagnostics 9.1 Error messages and flash codes for RF620R/RF630R Error code Description (B#16#...) Unexpected acknowledgement received. The parameters of the command and acknowledgement frame do not match ("command", "length", "address_MDS"). • The user changed the "command_DB_number/-_address" pointer during command execution. • The user changed the command parameters in the MOBY CMD data block (UDT 20) during command execution. • Check the parameter assignment of "ASM_address" and "ASM_channel". "ASM_address" and "ASM_channel" have the same parameter assignment for different channels. • The acknowledgement counter and command counter between the CM and FB are no longer synchronized – "init_run" needs to be executed 07 The "MOBY_mode" or "MDS_control" parameter (defined in UDT 10) has an invalid value 08 A bus error has occurred that is signaled by system functions SFB 52/53. More information on this error is available in the "error_BUS" variable. 09 • "ASM_address" or "ASM_channel" not available • "init_run" needs to be executed The CM has failed. • Loss of power on CM • PROFIBUS connector removed or PROFIBUS cable interrupted • "ASM_address" or "ASM_channel" not available This error is indicated if the "ASM_failure" bit was set in OB 122. OB 122 is called if FB 45 can no longer access the cyclic word for the CM. 0A 0B REVIEW 06 Another "init_run" was started while "init_run" was executing without waiting for "ready" • "init_run" must not be not set cyclically • The same physical channel/reader is used in two (or more) UDT 10 structures. Check "ASM_address" and "ASM_channel" in all UDT 10 structures. "init_run" cannot be executed; cyclic process image for the CM is disrupted; FB 45 reports a timeout of the process image for the CM The timeout time can be adapted in DBB 47 of UDT 10 if required. The default value is 50 (dec.) = 2 seconds. Greater values (255 max.) increase the timeout time. • "ASM_address" in UDT 10 has bad parameter settings. The "ASM_address" may be on the wrong module. • "ASM_channel" setting is ≥16 or ≤0 • CM hardware/firmware is faulty. • The same physical channel/reader is used in two (or more) UDT 10 structures. Check "ASM_address" and "ASM_channel" in all UDT 10 structures. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 475 System diagnostics 9.1 Error messages and flash codes for RF620R/RF630R Error code Description (B#16#...) 0C 0D Area length error on block move for FB 45. • "DAT_DB" does not exist or is set too small. "DAT_DB_number" and "DAT_DB_address" in UDT 20 need to be checked • Write command with length = 0 was sent • "init_run" needs to be executed An "init_run" was not completed correctly. The process image is inconsistent. This message is equivalent to a timeout. A timeout is reported 15s after starting "init_run". This time can be adjusted when necessary in DBW 44. • Execute "init_run" again • Turn CM off and on again • The "RUN-STOP" switch on the CPU was pressed rapidly several times in succession (particularly with slow PROFIBUS baud rates) • The same physical channel/reader is used in two (or more) UDT 10 structures. Check "ASM_address" and "ASM_channel" in all UDT 10 structures. error_BUS REVIEW Note The following table of bus errors does not claim to be complete. If you receive any messages that are not documented here, you will find them in the manual "System and standard functions S7-300/400, volume 1/2 (http://support.automation.siemens.com/WW/view/en/44240604)". Table 9- 3 Error variable "error_BUS" when operating via PROFIBUS/PROFINET Error code Description (W#16#...) 800A CM is not ready (temporary message) • This message is received by a user who is not using FB 45 and is querying the CM acyclically in very quick succession. 8x7F Internal error in parameter x. Cannot be remedied by the user. 8x22 8x23 Area length error when reading a parameter. Area length error when writing a parameter. This error code indicates that parameter x is partially or completely outside the operand range or the length of a bit array for an "ANY" parameter is not divisible by 8. 8x24 8x25 Area error when reading a parameter. Area error when writing parameter. This error code indicates that parameter x is in an area not allowed for the system function. 8x26 Parameter contains a time cell number that is too high. SIMATIC RF600 476 System Manual, xx/2014, J31069-D0171-U001-A15-7618 System diagnostics 9.1 Error messages and flash codes for RF620R/RF630R Error code Description (W#16#...) 8x27 Parameter contains a counter cell number that is too high. 8x28 8x29 Alignment error when reading a parameter. Alignment error when writing a parameter. The reference to parameter x is an operand whose bit address is not equal to 0. 8x30 8x31 The parameter is located in the write-protected global DB. The parameter is located in the write-protected instance DB. 8x32 8x34 8x35 The parameter contains a DB number that is too high. The parameter contains an FC number that is too high. The parameter contains an FB number that is too high. 8x3A 8x3C 8x3E The parameter contains a DB number that is not loaded. The parameter contains an FC number that is not loaded. The parameter contains an FB number that is not loaded. 8x42 An access error occurred while the system was attempting to read a parameter from the I/O area of the inputs. An access error occurred while the system was attempting to write a parameter to the I/O area of the outputs. 8x43 Error on nth (n > 1) read access after an error occurred. Error on nth (n > 1) write access after an error occurred. 8090 Specified logical base address is invalid: There is no assignment in SDB1/SDB2x, or it is not a base address. 8092 A type other than "BYTE" has been specified in an "ANY" reference. 8093 The area identifier contained in the configuration (SDB1, SDB2x) of the logical address is not permitted for these SFCs. Permitted: 80A0 • 0 = S7-400 • 1 = S7-300 • 2, 7 = DP modules REVIEW 8x44 8x45 Negative acknowledgment when reading from module; FB fetches acknowledgment although no acknowledgment is ready. A user who is not using the FB 45 would like to fetch DS 101 (or DS 102 to 104) although no acknowledgment is available. • Execute an "init_run" for resynchronization between CM and application 80A1 Negative acknowledgment while writing to the module. FB sends command although a CM is unable to receive a command 80A2 DP protocol error with layer 2 • DP-V1 mode must be set in the header module for distributed I/O. • Possible hardware defect 80A3 DP protocol error in Direct-Data-Link-Mapper or User-Interface/User. Could be a hardware defect. 80B0 • SFC not possible for module type. • Data record unknown to module. • Data record number ≥ 241 is not allowed. • Data records 0 and 1 are not permitted for SFB 52/53 "WR_REC". 80B1 The length specified in the "RECORD" parameter is wrong. 80B2 The configured slot is not occupied. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 477 System diagnostics 9.1 Error messages and flash codes for RF620R/RF630R Error code Description (W#16#...) 80B3 Actual module type is not the expected module type specified in "SDB1" 80C0 • RDREC: The module has the record, but there is no read data there yet. • WRREC: CM is not ready to receive new data – Wait until the cyclic counter has been incremented 80C1 The data of the preceding write job on the module for the same data record have not yet been processed by the module. 80C2 The module is currently processing the maximum possible number of jobs for a CPU. 80C3 Required resources (memory, etc.) are currently in use. This error is not reported by the FB 45. If this error occurs, the FB 45 waits until the system is able to provide resources again. REVIEW 80C4 80C5 Communication error • Parity error • SW ready not set • Error in block length management • Checksum error on CPU side • Checksum error on module side Distributed I/O not available. SIMATIC RF600 478 System Manual, xx/2014, J31069-D0171-U001-A15-7618 System diagnostics 9.2 Flashing codes RF640R/RF670R 9.2 Flashing codes RF640R/RF670R Flashing of ERR LED Repetitions Lit constantly Permanent Reader inactive, no configuration data Permanent Antenna 1 not connected or defective Permanent Antenna 2 not connected or defective Permanent Antenna 3 not connected or defective Permanent Antenna 4 not connected or defective 11 3 times Reading of user-defined memory has failed 12 3 times Writing of user-defined memory has failed 13 3 times The "SendCommand" function has failed 14 3 times Wrong or missing password 15 3 times Writing the transponder ID failed 16 3 times LOCK has failed 17 3 times KILL has failed 18 3 times Access to impermissible memory areas 19 3 times Too many transponders in the antenna field 20 Permanent General software errors 29 3 times Invalid frame; Bad frame parameters 30 3 times Incorrect message frame format 31 3 times The "SetReadProtect" NXP function has failed 32 3 times The "ResetReadProtect" NXP function has failed 33 3 times General error during identification of transponders (inventory) REVIEW Number Error description The LED states are described in the section Status display (Page 179). 9.3 Error messages RF640R/RF670R A description of the RF640R/RF670R error codes can be found in the "SIMATIC RF Function Manual". SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 479 System diagnostics 9.4 LED displays RF650R/RF680R/RF685R 9.4 LED displays RF650R/RF680R/RF685R Note that the RF650R reader does not provide an LED status display. With the help of the LED displays, you can read out the status and the error messages of the RF680R/RF685R readers. REVIEW The LED status display is in the middle on the front of the reader. The LED operating display is at the bottom on the front of the reader. ① ② LED status display (ST1 - ST9) - RF680R/RF685R only LED operating display • RUN/STOP (R/S) Shows whether the reader is ready for operation. • ERROR (ER) Indicates whether an error has occurred. • MAINTENANCE (MAINT) Shows whether the reader needs maintenance. • POWER (PWR) Shows whether the reader is supplied with power. • PRESENCE (PRE) RF650R only Shows whether one or several transponders are located in the antenna field. • LINK 1 (LK1) Shows that there is a connection via Ethernet interface "1". • RECEIVE/TRANSMIT 1 (R/T1) Shows that data is being sent and/or received via Ethernet interface "1". • LINK 2 (LK2) RF680R/RF685R only Shows that there is a connection via Ethernet interface "2". • RECEIVE/TRANSMIT 2 (R/T2) - RF680R/RF685R only Shows that data is being sent and/or received via Ethernet interface "2". Figure 9-1 LED displays of the reader With the LED operating display, you can read out the various operating statuses of the readers. The LED status display of the RF680R and RF685R readers has several functions. Among other things, the status display provides the following functions: SIMATIC RF600 480 System Manual, xx/2014, J31069-D0171-U001-A15-7618 System diagnostics 9.4 LED displays RF650R/RF680R/RF685R ● Error display If there is an error, the actual error is indicated by the lighting/flashing pattern. You will find more information on error messages in the section "xx". ● Display of RF activity Indicates that one or more transponders were detected. This function is indicated by the RF650R reader using the PRE LED. ● Indication of the quality of the antenna alignment (RSSI) When aligning the antenna, the status display indicates the RSSI value with which the transponder was detected. You will find more information on antenna alignment in the section "xx". 9.4.1 LED operating display The LED displays indicate the current reader status according to the following scheme: Display of the reader status with the LEDs Operating display LEDs R/S ER MT PR LK1 R/T Status display LEDs Meaning LK2 R/T Reader turned off Reader turned on (after startup) n. r. n. r. n. r. Reader ready for operation n. r. n. r. n. r. Reader working 9.4.2 REVIEW Table 9- 4 Error display by LEDs The display of the error messages using the LEDs is described in the section "Error messages RF640R/RF670R (Page 479)". SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 481 REVIEW System diagnostics 9.4 LED displays RF650R/RF680R/RF685R SIMATIC RF600 482 System Manual, xx/2014, J31069-D0171-U001-A15-7618 10 Accessories 10.1 Wide-range power supply unit for SIMATIC RF systems 10.1.1 Features Wide-range power supply unit for SIMATIC RF systems (1) DC output 1 (2) DC output 2 REVIEW (3) Mains connection Features • Wide-range input (3) for use worldwide • Dimensions without mains cable: 175 x 85 x 35 mm • Dimensions including mains cable: 250 x 85 x 35 mm • CE-compliant (EU and UK versions) • UL-certified for US and Canada (US version) • Mechanically and electrically rugged design • Secondary side (1), (2): 24 V DC / 3 A • Short-circuit and no-load stability • Suitable for frame mounting • 3 versions for use in the EU, UK, US SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 483 Accessories 10.1 Wide-range power supply unit for SIMATIC RF systems Description The wide-range power supply unit for SIMATIC RF systems is a universal compact power supply and provides the user with an efficient, cost-saving solution for many different midrange power supply tasks. The primary switched power supply is designed for use on single-phase AC systems. The two DC outputs (sockets) are connected in parallel and protected by a built-in current limiting circuit against overload and short-circuits. The device is vacuum-cast and prepared for Safety Class 2 applications. The EU and UK versions satisfy the low-voltage guideline as well as the current EU standards for CE conformity. Furthermore, the US version has been UL-certified for the US and Canada. 10.1.2 Scope of supply ● Wide-range power supply unit for SIMATIC RF systems ● 2 m mains cable (country-specific) ● Protective cover for flange outlet REVIEW ● Operating Instructions 10.1.3 Ordering data Wide-range power supply unit for SIMATIC RF-systems (100 - 240 VAC / 24 VDC / 3 A) with 2 m connecting cable with country-specific plug EU: 6GT2898-0AA00 UK: 6GT2898-0AA10 US: 6GT2898-0AA20 24 V connecting cable for SIMATIC RF640R/RF670R, length 5 m 6GT2891-0NH50 Note Risk of confusion Note that you cannot use the 24 V connecting cables of the discontinued RF660R reader for the RF640R and RF670R readers. SIMATIC RF600 484 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Accessories 10.1 Wide-range power supply unit for SIMATIC RF systems 10.1.4 Safety Information WARNING Danger to life It is not permitted to open the device or to modify the device. The following must also be taken into account: • Failure to observe this requirement shall constitute a revocation of the CE approval, UL certification for the US and Canada as well as the manufacturer's warranty. • For installation of the power supply, compliance with the DIN/VDE requirements or the country-specific regulations is essential. • The field of application of the power supply is limited to "Information technology in electrical office equipment" within the scope of validity of the EN 60950/VDE 0805 standard. • The housing can reach a temperature of +25 °C during operation without any adverse consequences. It must, however, be ensured that the power supply is covered in the case of a housing temperature of more than +25°C to protect persons from contact with the hot housing. Adequate ventilation of the power supply must be maintained under these conditions. Note REVIEW • When the equipment is installed, it must be ensured that the mains socket outlet is freely accessible. The wide-range power supply unit must only be used for SIMATIC products in the specifically described operating range and for the documented intended use. If the wide input range power supply for SIMATIC RF systems is used for an end product other than the SIMATIC RF600 system, the following must be taken into account: ● The electric strength test of the end product is to be based upon a maximum working voltage of: Transition from primary to SELV: 353 VDC, 620 Vpk ● The following secondary output circuits are SELV (low voltage; SELV = Safety Extra Low Voltage): all ● The following secondary output circuits are at non-hazardous energy levels: all ● The power supply terminals and/or connectors are suitable for field wiring if terminals are provided. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 485 Accessories 10.1 Wide-range power supply unit for SIMATIC RF systems ● The maximum investigated branch circuit rating is: 20 A ● The investigated pollution degree is: 2 WARNING If the wide input range power supply for SIMATIC RF systems is connected to an end product other than end products of the RF600 family, the end user is responsible and liable for operation of the system or end product that includes the wide input range power supply for SIMATIC RF systems. WARNING Alterations to the SIMATIC RF600 components and devices as well as the use of SIMATIC RF600 components with third-party RFID devices are not permitted. Failure to observe this requirement shall constitute a revocation of the radio equipment approvals, CE approval and manufacturer's warranty. Furthermore, the compliance to any salient safety specifications of VDE/DIN, IEC, EN, UL and CSA will not be guaranteed. Safety notes for the US and Canada REVIEW The SIMATIC RF640R/RF670R reader may only be operated with the wide range power supply unit for SIMATIC RF systems - as an optional component – or with power supply units that are UL-listed according to the safety standards specified below: ● UL 60950-1 - Information Technology Equipment Safety - Part 1: General Requirements ● CSA C22.2 No. 60950 -1 - Safety of Information Technology Equipment. WARNING The compliance of the SIMATIC RF600 system to the safety standards mentioned above will not be guaranteed if neither the wide-range power supply unit for SIMATIC RF systems°nor power supplies listed according to the safety standards above are used. SIMATIC RF600 486 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Accessories 10.1 Wide-range power supply unit for SIMATIC RF systems Safety information for Korea WARNING The SIMATIC RF640R/RF670R Reader may only be operated with power supplies that have received KETI approval. There is currently no KETI approval for the wide-range power supply (6GT2898-0AAx0). This is why the wide-range power supply may not be operated in South Korea. To use the SIMATIC RF640R/RF670R Reader in South Korea, you need a power supply (24 V DC / 3 A). This power supply must meet the requirements of the application field and have a KETI approval. You also need the connection cable for the SIMATIC RF640R/RF670R (6GT2891-0NH50). For the required pin assignments of the DC output for connecting the power supply, see section Pin assignment of DC outputs and mains connection (Page 490). You can find the pin assignment of the DC inputs for the reader in sections Pin assignment for power supply (Page 138) and Pin assignment for power supply (Page 185). Connecting REVIEW 10.1.5 ● There are three different (country-specific) mains cables for the EU, UK and US. The appropriate mains cable must be connected to the primary input of the power supply. Note It is only permissible to insert or remove the mains cable when the power supply is deenergized. ● The wide-range power supply unit has total insulation (Safety Class 2), IP65 ● It can be mounted using four fixing holes. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 487 Accessories 10.1 Wide-range power supply unit for SIMATIC RF systems 10.1.6 Technical specifications Table 10- 1 General technical specifications Insulation stability (prim./sec.) Uins p/s 3.3 kVAC Insulation resistance Rins >1 GΩ Leakage current Ileak Uin = 230 VAC, f = 50 Hz Safety class (SELV) Designed for installation in devices of Safety Class 2 Mains buffering th Uin = 230 VAC Ambient temperature Surface temperature ≥ 50 ms -25 °C to +55 °C Module top, center Max. 96 °C Storage temperature -40 °C to +85 °C Self-heating on full-load max. 45 K Interference immunity ESD HF fields Burst Surge HF injection Mains quality test REVIEW < 200 µA EN 61000-4-2, 4-3 up to 4-6, 4-11 Air discharge: 15 kV 10 V/m symmetrical: 2 Symmetrical: 1 10 Vrms Cooler Free convection Dimensions L x W x H 175 mm x 85 mm x 35 mm Weight 720 g Housing / casting UL 94-V0 Power supply class according to CSA Degree of protection IP65 MTBF in years Table 10- 2 Level 3 255 Technical specifications for the input Rated input voltage Uin EN 60950 / UL 60950 100 to 240 VAC 120 to 353 VDC Input voltage range Uin 94 to 264 VAC 120 to 375 VDC (UL: 353 VDC) Input frequency fin 50/60 Hz Radio interference level EN 55011/B Switching frequency fsw approx. 70 kHz typ. Length of cable 2m Table 10- 3 Technical specifications of the output Output voltage tolerance ∆Uout Uin = 230 VAC Overvoltage protection Noise ∆ULF Uout nom ≤ +2 %/-1 % Uout nom +20 % typ. Uin = min., BW: 1 MHz ≤ 1 % Uout SIMATIC RF600 488 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Accessories 10.1 Wide-range power supply unit for SIMATIC RF systems Noise ∆UHF Uin = min., BW: 20 MHz ≤ 2 % Uout Line Regulation Load Regulation Uin = min./max. Iout = 10...90...10 % ≤ 1,0 % ≤ 1,0 % Short-circuit current Imax Inom = 4 A (+50°C) 105 ... 130 % Inom Settling time tR load variations Iout = 10...90...10 % < 5 ms Temperature coefficient ε TA = -25 °C to +70 °C 0.01 %/K Overload behavior Pover Constant current Short-circuit protection/ No-load response Continuous/no-load stability Derating Connector type TA > +50 °C to +70 °C max. 2 %/K Flanged connector 4 pins Binder, Order no.: 09-3431-90-04 Output configurations Input Outputs ILoad = Efficiency U1 = U2 I1 + I2 (%) 110 VAC 24 VDC 0A 110 VAC 24 VDC 3A 220 VAC 24 VDC 0A 220 VAC 24 VDC 3A Table 10- 5 Remarks No-load stability ≥ 88 No-load stability ≥ 90 REVIEW Table 10- 4 Compliance with standards Designation Standard Electrical safety EN 60950 / UL 60950 / CAN/CSA 22.2 950, 3 Edition Values Conducted interference EN 61000-6-3 EN 55011 Class B Emission EN 61000-6-3 EN 55011 Class B All values are measured at full-load and at an ambient temperature of 25 °C (unless specified otherwise). SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 489 Accessories 10.1 Wide-range power supply unit for SIMATIC RF systems 10.1.7 Pin assignment of DC outputs and mains connection DC outputs Assignment (1) Ground (0V) (2) +24 V DC (3) +24 V DC (4) Ground (0V) Mains connection Assignment (1) 100 to 240 V AC (2) n.c. (3) 100 to 240 V AC REVIEW (4) n.c. SIMATIC RF600 490 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Accessories 10.1 Wide-range power supply unit for SIMATIC RF systems Dimension drawing Units of measurement: REVIEW 10.1.8 All dimensions in mm SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 491 Accessories 10.1 Wide-range power supply unit for SIMATIC RF systems 10.1.9 Certificates and approvals Table 10- 6 Certificate Wide-range power supply unit for SIMATIC RF systems 6GT2898-0AA00 - Europe, 6GT2898-0AA10 - UK Description CE approval to 2004/108/EC EMC 73/23/EEC LVD Table 10- 7 Wide-range power supply unit for SIMATIC RF systems 6GT2898-0AA20 - USA Standard This product is UL-certified for the US and Canada. It meets the following safety standards: UL 60950-1 - Information Technology Equipment Safety - Part 1: General Requirements REVIEW CSA C22.2 No. 60950 -1 - Safety of Information Technology Equipment UL Report E 205089 SIMATIC RF600 492 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Accessories 10.2 The PC adapter for SIMATIC RF-DIAG 10.2 The PC adapter for SIMATIC RF-DIAG 10.2.1 Description PC adapter for SIMATIC RF-DIAG ① USB interface ② RS-422 – CM / wide-range power supply unit The SIMATIC RF-DIAG product consists of a CD with software and documentation and a hardware packet. The hardware packet consists of a PC adapter for SIMATIC RF-DIAG, a USB connecting cable and an RS-422 cable. The PC adapter for SIMATIC RF-DIAG is a converter from USB to RS-422. Communication between the PC and reader can be established using the PC adapter. REVIEW ③ RS-422 – RF reader Characteristics ● RS-422 to USB converter for communication with the RF620R and RF630R ● Dimensions without connecting cables: 101 x 63 x 35 mm ● CE-compliant (EU and UK versions) ● FCC-compliant for use in the USA and Canada ● Mechanically and electrically rugged design ● RS-422 interface – With 24 VDC / 3 A for CM or wide-range power supply unit – With 24 VDC / 3 A for reader ● Short-circuit proof SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 493 Accessories 10.2 The PC adapter for SIMATIC RF-DIAG Highlights ● Diagnostics via a PC with the reader supplied with power from the system ● IP65 degree of protection ● Can be used in high temperature ranges ● Use in productive operation possible ● Switchover to diagnostics mode "on the fly" (parallel to regular operation) Note Protection from environmental influences The IP65 degree of protection of the PC adapter is only valid if the USB protective cap is fitted and the corresponding RS-422 cable is connected. During diagnostics, this degree of protection is not present. REVIEW 10.2.2 Pin assignment of the RS-422 interface Pin assignment for connection to the CM or wide-range power supply unit Pin assignment of the connector for PC adapter and CM or wide-range power supply unit Table 10- 8 Pin RS-422 interface of the PC adapter (male connector) Pin Assignment for Device end 8- CM pin M12 Assignment for wide-range power supply unit + 24 V + 24 V - Transmit Free 0V 0V + Transmit Free + Receive Free - Receive Free Free Free Ground (shield) Ground (shield) The knurled bolt of the M12 plug does not contact the shield (reader end). SIMATIC RF600 494 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Accessories 10.2 The PC adapter for SIMATIC RF-DIAG Pin assignment of the connecting cable between PC adapter and CM or wide-range power supply unit Table 10- 9 RS-422 connecting cable View of M12 socket M12 pin Core color Pin assignment for CM Pin assignment for wide-range power supply unit White 24 VDC 24 VDC Brown TX neg Not used green GND GND Yellow TX pos Not used gray RX pos Not used pink RX neg Not used Blue Not used Not used Red Ground (shield) Ground (shield) Pin assignment of the connector for PC adapter and UHF reader Table 10- 10 RS-422 interface of the PC adapter (female connector) Pin Pin Assignment for the RF readers REVIEW Pin assignment for connecting to the RF readers Device end 8pin M12 + 24 V - Transmit 0V + Transmit + Receive - Receive Free Ground (shield) The knurled bolt of the M12 plug does not contact the shield (reader end). SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 495 Accessories 10.2 The PC adapter for SIMATIC RF-DIAG Pin assignment of the connecting cable between PC adapter and UHF reader Table 10- 11 RS-422 connecting cable View of M12 plug M12 pin Wire color Pin assignment White 24 VDC Brown TX neg green GND Yellow TX pos gray RX pos pink RX neg Blue Not used Red Ground (shield) Pin assignment for connection to the PC Table 10- 12 USB 2.0 mini-B connector socket of the PC adapter REVIEW View of connection socket Pin Assignment Device side +5V Data - Data + ID (not used) GND Table 10- 13 USB 2.0 mini-B plug of the connecting cable View of mini-B plug Pin Wire color Assignment Red +5V White Data - green Data + ID (not used) Black GND Device side SIMATIC RF600 496 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Accessories 10.2 The PC adapter for SIMATIC RF-DIAG 10.2.3 Technical specifications Table 10- 14 Mechanical data Property Description Weight 310 g Dimensions (L x W x H) 101 × 63 × 35 mm Enclosure material Aluminum (painted) Housing color Black Installation No securing aids Interfaces RS422 USB MTBF in years • 1 x pin (8-pin M12, connection to CM/wide-range power supply) • 1 x socket (8-pin M12, connection to the reader) USB 2.0 Mini-B 1.1x103 Property Description Software – RS-422 SIMATIC S7 / TIA Software – USB • RF600 • 3964R & RF-DIAG REVIEW Table 10- 15 Software interfaces Table 10- 16 Electrical data Property Description Power supply of the PC adapter via USB (during operation) • Nominal value • 5 V DC • Permitted range • 4.0 to 5.25 VDC • 24 VDC • 20 to 30 VDC Power supply of the RF readers via RS-422 • Nominal value • Permitted range Current consumption • Connection via USB and RS-422 • Via 5 VDC, approx. 30 mA; 24 VDC, approx. 15 mA • No connection via USB • Via 24 VDC, ≤ 5 mA • 19.2 Kbps • 57.6 Kbps • 115.2 Kbps Transmission rates USB / RS-422 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 497 Accessories 10.2 The PC adapter for SIMATIC RF-DIAG Table 10- 17 Ambient conditions Property Description Temperature range during operation -25 ℃ to +70 ℃ Temperature range during storage -40 ℃ to +85 ℃ Shock resistant to EN 60068-2-27 50 g, 1) Vibration resistant to EN 60068-2-6 20 g, 1) Degree of protection in accordance with EN 60529 IP65 2) The values for shock and vibration are maximum values and must not be applied continuously nor when the USB plug is plugged in. 2) Only when the USB protective cap is fitted and the corresponding RS-422 cables are connected. REVIEW 1) SIMATIC RF600 498 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Accessories 10.2 The PC adapter for SIMATIC RF-DIAG Dimension drawing REVIEW 10.2.4 Figure 10-1 Dimension drawing of the PC adapter for SIMATIC RF-DIAG (all dimensions in mm) When the USB protective cap is screwed on, the length of the adapter is 134 mm. The tolerances are +/- 1 mm. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 499 Accessories 10.2 The PC adapter for SIMATIC RF-DIAG 10.2.5 Certificates and approvals Table 10- 18 Certificates and approvals for the PC adapter Certificate Description CE approval complying with 2004/108/EC EMC FCC Rules, Part 15, Subpart B, Sections 15.107 and 15.109 CAN/CSA-CISPR 22-10 - Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement REVIEW Industry Canada Radio Standards Specifications SIMATIC RF600 500 System Manual, xx/2014, J31069-D0171-U001-A15-7618 A Appendix A.1 Certificates and approvals Notes on CE marking The following applies to the system described in this documentation: The CE marking on a device is indicative of the corresponding approval: DIN ISO 9001 certificate The quality assurance system for the entire product process (development, production, and marketing) at Siemens fulfills the requirements of ISO 9001 (corresponds to EN29001: 1987). This has been certified by DQS (the German society for the certification of quality management systems). EQ-Net certificate no.: 1323-01 Table A- 1 FCC IDs: NXW-RF660, NXW-RF620R, NXW-RF630R, IC: 267X-RF620R, IC: 267XRF630 Standards FCC Title 47, Part 15.sections 15.247 Federal Communications Commission Industry Canada Radio Standards Specifications Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. RSS-210 Issue 6, Sections 2.2, A8 This product is UL-certified for the USA and Canada. It meets the following safety standard(s): UL 60950-1 - Information Technology Equipment Safety - Part 1: General Requirements CSA C22.2 No. 60950 -1 - Safety of Information Technology Equipment UL Report E 205089 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 501 Appendix A.1 Certificates and approvals Certification for the USA, Canada and Australia Safety One of the following markings on a device is indicative of the corresponding approval: Underwriters Laboratories (UL) to UL 60950 Standard (I.T.E), or to UL508 (IND.CONT.EQ) Underwriters Laboratories (UL) according to Canadian standard C22.2 No. 60950 (I.T.E) or C22.2 No. 142 (IND.CONT.EQ) Underwriters Laboratories (UL) according to standard UL 60950, Report E11 5352 and Canadian standard C22.2 No. 60950 (I.T.E) or UL508 and C22.2 No. 142 (IND.CONT.EQ) UL recognition mark Canadian Standard Association (CSA) per Standard C22.2. No. 60950 (LR 81690) or per C22.2 No. 142 (LR 63533) Canadian Standard Association (CSA) per American Standard UL 60950 (LR 81690) or per UL 508 (LR 63533) EMC USA Federal Communications This equipment has been tested and found to comply with the limits for a Commission Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful Radio Frequency interference when the equipment is operated in a commercial Interference Statement environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Shielded Cables Shielded cables must be used with this equipment to maintain compliance with FCC regulations. Modifications Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. Conditions of Operations This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CANADA Canadian Notice This Class B digital apparatus complies with Canadian ICES-003. Avis Canadien Cet appareil numérique de la classe b est conforme à la norme NMB-003 du Canada. SIMATIC RF600 502 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Appendix A.1 Certificates and approvals AUSTRALIA This product meets the requirements of the AS/NZS 3548 Norm. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 503 Appendix A.2 Service & support A.2 Service & support Technical Support You can access technical support for all IA/DT projects via the following: ● Phone: + 49 (0) 911 895 7222 ● Fax: + 49 (0) 911 895 7223 ● Web form for support request (http://www.siemens.com/automation/support-request) ● Internet: E-mail (mailto:support.automation@siemens.com) Contacts If you have any further questions on the use of our products, please contact one of our representatives at your local Siemens office. The addresses are found on the following pages: ● On the Internet (http://www.siemens.com/automation/partner) ● In Catalog CA 01 ● In the catalog ID 10 specially for Industrial Identification Systems Service & support for industrial automation and drive technologies You can find various services on the Support home page (http://www.siemens.com/automation/service&support) of IA/DT on the Internet. There you will find the following information, for example: ● Our newsletter containing up-to-date information on your products. ● Relevant documentation for your application, which you can access via the search function in "Product Support". ● A forum for global information exchange by users and specialists. ● Your local contact for IA/DT on site. ● Information about on-site service, repairs, and spare parts. Much more can be found under "Our service offer". SIMATIC documentation on the Internet A guide to the technical documentation for the various SIMATIC products and systems is available on the Internet: SIMATIC Guide manuals (http://www.siemens.com/simatic-tech-doku-portal) SIMATIC RF600 504 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Appendix A.2 Service & support RFID homepage For general information about our identification systems, visit RFID home page (http://www.siemens.com/ident/rfid). Online catalog and ordering system The online catalog and the online ordering system can also be found on the Industry Mall home page (http://www.siemens.com/industrymall/en). Training center We offer appropriate courses to get you started. Please contact your local training center or the central training center in D-90327 Nuremberg. Phone: +49 (0) 180 523 56 11 (€ 0.14 /min. from the German landline network, deviating mobile communications prices are possible) For information about courses, see the SITRAIN home page (http://www.sitrain.com). SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 505 Appendix A.2 Service & support SIMATIC RF600 506 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Glossary Active field Area with minimum field strength containing the sensing range. Within this sensing range, data can be read from the tag or written to the tag. Active surface See active field See active field Active surface See active field See active field Active tag/transponder Active transponders are battery-operated, i.e. they obtain the energy required to save data on the microchip from a built-in battery. They are usually in an idle state and do not transmit data in order to increase the energy source's service life. The transmitter is only activated when it receives a special activation signal. AM Amplitude modulation; data are present in the changes in carrier frequency amplitude. Amplitude modulation See AM AS See Automation system ASM Interface module, see Communication modules Automation system (AS) A programmable logical controller (PLC) of the SIMATIC S7 system, comprising a central controller, a CPU and various I/O modules. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 507 Glossary Battery-free data storage unit Mobile data storage units which operate without batteries. (See transponder). Power is supplied to the data storage unit across an electromagnetic alternating field. Baud Unit (digits per second). Baud rate The baud rate describes the data transmission's digit rate. Byte A group of eight bits CE guidelines See CE Label CE Label Communauté Européenne (product mark of the European Union) Communication modules Communication modules are used to integrate the identification systems in SIMATIC or SINUMERIK systems, or to connect them to PROFIBUS, PROFINET, PC or any other system. Once supplied with the corresponding parameters and data, they handle data communication. They then make the corresponding results and data available. Suitable software blocks (FB/FC for SIMATIC; C libraries for PCs with Windows) ensure easy and fast integration in the application. Continuous Wave See CW CW Continuous Wave; data are present in the carrier frequency which is switched on and off. Data rate The rate at which data are exchanged between the tag and reader. Typical units are bits per second or bytes per second. SIMATIC RF600 508 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Glossary Data transfer rate Number of characters which can be transmitted from a tag to a reader within a defined time. Baud rates are also used to specify how fast a reader can read information. Data transmission rate Unit of measurement for the volume of data transmitted within a unit of time, e.g. bytes/s, see also Baud dB See Decibel dBm Dimensional unit for the transmitted power in the logarithmic relation to 1 mW (Milliwatt). 0dBm = 1mW, +23dBm = 200mW, +30dBm = 1W. dBr dB(relative); a relative difference to a reference value Decibel (dB) Unit of measurement for the logarithmic relationship between two variables. Dense Reader Mode (DRM) In this mode, tag readability is increased through the application of interference-reducing measures. DRM is only defined for Gen 2 and does not function with other tag types. Detuning UHF antennas are tuned to receive a particular electromagnetic wavelength from the reader. If the antenna is too close to metal or a metallic material, it can be detuned, making the performance deteriorate. Distant field communication RFID antennas emit electromagnetic waves. If a tag is more than a full wavelength away from the reader's transmitting antenna, it is in a "distant field". If it is within a full wavelength, this is known as the "near field". The wavelength of UHF-RFID systems is approx. 33 cm. The distant field signal is attenuated with the square of the distance from the antenna, whereas the near field signal is attenuated with the cube of the distance from the antenna. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 509 Glossary Passive RFID systems based on distant field communication (UHF and microwave systems) have a greater read range than systems based on near field communication (typically lowfrequency and high-frequency systems). Dwell time The dwell time is the time in which the transponder dwells within the sensing range of a reader. The reader can exchange data with the transponder during this time. Dynamic mode In dynamic mode, the data carrier moves past the reader at a traversing rate which depends on the configuration. Various checking mechanisms ensure error-free data transfer even under extreme environmental conditions. EAN European article number. Standardized barcode used in Europe, Asia and South America. Is administered by EAN International. EBS Equipotential Bonding Strip Effective Isotropic Radiated Power See EIRP Effective Radiated Power See ERP. EIRP Effective Isotropic Radiated Power; unit of measurement for the transmission power of antennas (referred to an isotropic radiator) mainly used in the USA. EIRP is specified in Watt, and is not equal to ERP. (0dbi = - 2.14 dBm) Electromagnetic compatibility (EMC) Electromagnetic compatibility is the ability of an electrical or electronic device to operate satisfactorily in an electromagnetic environment without affecting or interfering with the environment over and above certain limits. EMC See Electromagnetic compatibility SIMATIC RF600 510 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Glossary EMC directive Guidelines for electromagnetic compatibility This guideline relates to any electrical or electronic equipment, plant or system containing electric or electronic components. EPC See EPC global EPC global Electronic Product Code. Standardized number system for identifying articles with a data width of either 64, 96 or 256 bits. Equipotential bonding Potential differences between different parts of a plant can arise due to the different design of the plant components and different voltage levels. It is necessary to compensate for these differences by equipotential bonding: this is done by combining the equipotential bonding conductors of power components and non-power components on a centralized equalizing conductor (EBS = Equipotential Bonding Strip). ERP Effective Radiated Power; unit of measurement for the transmission power of antennas (referred to an ideal dipole) mainly used in Europe. ERP is specified in Watt, and is not equal to EIRP. (0dbm = + 2.14 dBi) ESD directive Directive for handling Electrostatic Sensitive Devices ETSI European Telecommunications Standard Institute European Article Numbering See EAN. eXtensible markup language See XML. FCC Federal Communications Commission (USA) SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 511 Glossary FHSS Frequency Hopping Spread Spectrum; frequency change procedure. FM Frequency modulation; data are present in the changes in the frequency of the carrier frequency. Frequency hopping Frequency hopping technique Automatic search for free channels. In frequency hopping, data packets are transferred between the communication partners on constantly changing carrier frequencies. This makes it possible to react to interference from devices transmitting signals in the same frequency range (channel). If an attempt to send a data packet is unsuccessful, the packet can be transmitted again on a different carrier frequency. By default the RF600 uses this procedure (FCC) only in the USA and Canada. Frequency modulation See FM. Frequency Shift Keying See FSK FSK Modulation, Frequency Shift Keying; data are present in the changes between two frequencies. ICNIRP International Commission of Non Ionizing Radiological Protection ICRP International Commission of Radiological Protection Interface modules See communication modules Interrogator See readers SIMATIC RF600 512 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Glossary ISO International Standard Organization ISO 18000 Standard for data exchange of RFID systems between reader and transponder. There are various subdefinitions of this standard for the various approved frequency ranges for RFID. For example, the range 865 ... 868 MHz is described in ISO 18000-6. LAN Local Area Network LBT Listen Before Talk; the reader only transmits when the channel is free. License plate 10-digit code that is saved on every RFID tag. The code of the license plate establishes a connection between the item of baggage and the baggage processing system of the airport. As soon as the license plate has been read by the reader, a message is automatically sent to the baggage processing system. This message contains important data regarding the flight and destination of the item of baggage. Using this data, the item of baggage can be successfully sorted by the baggage processing system of the airport. Limit distance The limit distance is the maximum clear distance between reader antenna and transponder at which the transmission can still function under normal conditions. Mass recording The capability of a reader to record several or many transponders quasi-simultaneously and to read the code. Contrary to the multi-tag capability, the reader is not able to specifically address individual tags. MDS Mobile data memory, see Transponder. MES Manufacturing Execution System SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 513 Glossary Metal-free area Distance/area which must be maintained between the transponder and metal in order to prevent interference during data transfer between the transponder and reader. Mobile Data Memory (MDS) Mobile data memory, see Transponder Modulation Modulation is a procedure with which one or more characteristics (e.g. phase, amplitude, frequency) of a carrier oscillation are modified according to the response of a modulating oscillation. Multi-tag capability Multi-tag capability means that a reader can communicate simultaneously with different data carriers. Therefore the reader can specifically address a transponder with its UID (see also mass recording). Near field communication RFID antennas emit electromagnetic waves. If a tag is more than a full wavelength away from the reader's transmitting antenna, it is in a "distant field". If it is within a full wavelength, this is known as the "near field". The wavelength of UHF-RFID systems is approx. 33 cm. The distant field signal is attenuated with the square of the distance from the antenna, whereas the near field signal is attenuated with the cube of the distance from the antenna. Passive RFID systems based on near field communication (typically low-frequency and highfrequency systems) have a greater read range than systems based on distant field communication (typically UHF and microwave systems). Passive tag If electromagnetic waves from the reader reach the tag antenna, the energy is converted by the antenna into electricity which provides the tag chip with current. The tag is able to return information stored on the chip. Passive tags do not usually have a battery. A battery is required if the tag has a RAM, but the battery is only used to save information in the RAM. In particular, the battery is not used for data exchange between reader and transponder. Passive tag/transponder A tag without its own power supply. Passive transponders obtain the energy required to supply the microchips from the radio waves they receive. SIMATIC RF600 514 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Glossary PDM Pulse duration modulation; data are present in the pulse duration. Phase modulation See PM PLC Programmable Logic Controller, see PLC. Programmable logic controller; electronic device used in automation engineering for openloop and closed-loop control tasks. The typical modules of a PLC are the CPU, power supply (PS) and various input/output modules (I/O). Programmable controller: The programmable logical controllers (PLC) of the SIMATIC S5 system consist of a central controller, one or more CPUs, and various other modules (e.g. I/O modules). PLC Programmable Logic Controller, see PLC. Programmable logic controller; electronic device used in automation engineering for openloop and closed-loop control tasks. The typical modules of a PLC are the CPU, power supply (PS) and various input/output modules (I/O). Programmable controller: The programmable logical controllers (PLC) of the SIMATIC S5 system consist of a central controller, one or more CPUs, and various other modules (e.g. I/O modules). PLC Programmable Logic Controller, see PLC. Programmable logic controller; electronic device used in automation engineering for openloop and closed-loop control tasks. The typical modules of a PLC are the CPU, power supply (PS) and various input/output modules (I/O). Programmable controller: The programmable logical controllers (PLC) of the SIMATIC S5 system consist of a central controller, one or more CPUs, and various other modules (e.g. I/O modules). PM Phase modulation; data are present in the changes in carrier frequency phase. Programmable Logic Controller See PLC. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 515 Glossary Programmable Logic Controllers See PLC Protocol A combination of rules which manage communications systems. Pulse duration modulation See PDM Radio Frequency Identification See RFID. Read rate Number of tags which can be read within a defined time. The read rate can also be used for the maximum rate at which data can be read from a tag. The unit is bits per second or bytes per second. Reader (also interrogator) Readers transfer data between mobile data memories (transponders) and the higher-level systems. The data, including the energy required for processing and sending back, are transmitted to the transponder across an electromagnetic alternating field. This principle enables contact-free data transmission, ensures high industrial compatibility and works reliably in the presence of contamination or through non-metallic materials. Reader talks first A passive tag communicates in the read field of a reader with the reader. The reader sends energy to the tags which only reply when they are explicitly requested. The reader is able to find tags with a specific serial number commencing with either 1 or 0. If more than one tag responds, the reader can scan all tags commencing with 01 and subsequently with 010. This is referred to as "walking" on a binary tree, or "tree walking". Reading range The distance within which a reader can communicate with a tag. Active tags can cover a greater distance than passive tags because they use a battery to send signals. Reciprocity Reciprocity means that a two-way relationship exists between the transmit and receive case of a passive antenna. SIMATIC RF600 516 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Glossary RFID Radio Frequency Identification; a method of identifying items using electromagnetic waves. The reader supplies energy to the tag and communicates with it. RFID systems SIMATIC RF identification systems control and optimize material flow and production sequences. They identify reliably, quickly and economically, use non-contact data communication technology, and store data directly on the product. They are also resistant to contamination. RH circular Right hand circular polarization RSSI threshold value The "Received Signal Strength Indication" (RSSI) is an indicator of the receive field strength of the transponders. When the field strength with which the transponder is received undershoots the set RSSI threshold, the reader ignores the signal of this transponder. The RSSI threshold value can be activated to limit areas of the antenna fields to those in which transponders should still be accessed. This can be used to avoid undesirable effects, such as range overshoot when reading transponder data. RTNC Connector designation (Reverse TNC). Industrial coaxial connector with screw coupling, can be used for frequencies of up to 2 GHz. The mechanical design of the RTNC connector is not compatible with the TNC connector. RTTE Radio and Telecommunications Terminal Equipment SCM Supply Chain Management Secondary fields In addition to the main sensing range (antenna's main direction of transmission) there are secondary fields. These secondary fields are usually smaller than the main fields. The shape and characteristics of the secondary field depend on the metallic objects in the surroundings. Secondary fields should not be used in configuring. SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 517 Glossary SELV Safety Extra Low Voltage Sensing range Area in which reliable data exchange between transponder and reader is possible due to a particular minimum field strength. SSB Single Sideband Modulation. SSB is similar to AM (amplitude modulation), however, only one sideband is sent instead of two sidebands. This saves 50% of the spectrum required in the HF channel without affecting the signal/data rate. For RFID applications, an HF carrier must also be sent to supply energy to the tag. Sending a carrier is many times not required for other SSB applications, since the HF carrier itself does not contain any data. Static mode In static mode the transponder is positioned at a fixed distance (maximum: limit distance) exactly above the reader. Tag See transponder Tag talks first A passive tag communicates in the read field of a reader with the reader. When a tag reaches the field of a reader, it immediately indicates its presence by reflecting a signal. TARI Abbreviation of Type A Reference Interval. Duration (period) for representation of a bit with content 0. TCP/IP Transmission Control Protocol/Internet Protocol Telegram cycles A passive tag communicates in the read field of a reader with the reader. When a tag reaches the field of a reader, it immediately indicates its presence by reflecting a signal. Transmission of a read or write command is implemented in three cycles. They are called "Telegram cycles". One or two bytes of user data can be transferred with each command. The acknowledgment or response transfer (status or read data) takes place in three further cycles. SIMATIC RF600 518 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Glossary TNC Connector designation (Threaded Neill Concelman). Industrial coaxial connector with screw coupling, can be used for frequencies of up to 2 GHz. Transceiver (transmitter/receiver) Combination of transmitter and receiver. A unit which can both send and receive electromagnetic waves. Transmission distance Distance between communication module and transponder Transponder An invented word from transmitter and responder. Transponders are used on the product, the product carrier, the object, or its transport or packaging unit, and contain production and manufacturing data, i.e. all application-specific data. They follow the product through assembly lines, transfer and production lines and are used to control material flow. Because of their wireless design, transponders can be used, if necessary, at individual work locations or manufacturing stations, where their data can be read and updated. Tree walking See Reader talks first. UHF Ultra-high frequency; frequency range from 300 MHz to 3 GHz. UHF RFID tags usually operate between 866 MHz and 960 MHz. This corresponds to a wavelength of approx. 33 cm. UID User IDentifier; the UID is an unambiguous number in the transponder, assigned by the manufacturer. The UID is unambiguous, and can usually also be used as a fixed code. The UID is used to specifically address a transponder Ultra High Frequency See UHF. User IDentifier See UID SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 519 Glossary VESA Video Electronics Standards Association (authority that defines standards for the PC industry) Walking See Reader talks first. WLAN Wireless LAN writer See readers Writing/reading range See transmission distance XML eXtensible markup language; XML is a language derived from SGML with which other languages (document types) can be described. In the meantime, XML is a widely used language for distributing information on the Internet. Data exchange between reader and read station is carried out using XML commands. SIMATIC RF600 520 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Index Antenna cable Connector type, 70 Antenna cables, 70 Bending radius, 70 Antenna configuration, 43 Antenna gain, 61 Cable loss 4 dB, 61 Dependency on plane, 62 FCC, 61 Frequency dependency, 62 Antenna mounting kit RF620R, 103 RF640R, 148 RF650R, 170 RF670R, 188 RF680R, 209 RF685R, 235 Appearance of resonance, 69 Beam angle, 68 Read area, 68 Beam width Definition, 66 ETSI, 66 Bending radius Antenna cables, 70 Cable Shielding, 84 Cable loss Definition, 69 Dependencies, 69 Characteristic impedance Definition, 69, 69 Circular polarization, 64 Classes, 334 Coaxial antenna cables Coaxial, 70 Configuration, 103, 119 Antennas, 43 Connector type, 70 R-TNC, 70 Thread, 70 Contacts, 504 Courses, 505 Decibel Calculation example, 60 Definition, 60 Reference variables, 61 Design of the RF640R reader, 129 Design of the RF650R reader, 158 Design of the RF670R reader, 177 Design of the RF680R reader, 198 Design of the RF685R reader, 217 Dimensions RF620R reader, 108 RF630R reader, 124 RF650R reader, 173 RF670R reader, 193 RF680R reader, 213 RF685R reader, 239 Directional antennas, 58 EIRP, 59 Electromagnetic interference, 82 Electromagnetic waves UHF range, 73 EMC Directives, 502 Propagation of electromagnetic interference, 82 EMC Guidelines Basic Rules, 80 Cable shielding, 85 Definition, 79 Equipotential bonding, 83 Overview, 79 Equipotential bonding, 83 ERP, 59 Cable loss, 60 Logarithmic, standardized, 59 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 521 Index Front-to-back ratio, 65 Functions Overview, 244 Gate configuration Application areas, 44 Arrangement of antenna, 44 Generations, 334 Identification system UHF range, 29 Impedance Definition, 62 Specifications, 62 Influence of Interference, 73 Liquids, 74 Metals, 74 Non-metallic substances, 74 reflections, 73 Influencing factors, 56 Interfaces, 103, 119 Digital, 132 RS422, 103 Interference, 73 Interference sources Electromagnetic, 82 Isotropic radiator, 59 Isotropic spherical radiator, 61 Linear polarization, 65 Main applications RF600, 31 RF620R, 31 RF630R, 31 RF640R, 31 RF680M, 31 RF-MANAGER, 31 Main beam direction, 65 Minimum spacing For antennas, 49 Mounting of RF620R Antenna mounting kit, 103 Mounting of RF670R Antenna mounting kit, 188 Mounting types of the RF620R reader, 103 Mounting types of the RF630R reader, 119 Ordering data for RF670R, 178 Accessories, 178 Ordering data RF640R, 130 Accessories, 130 Ordering data RF650R, 158 Accessories, 159 Ordering data RF680R, 198 Accessories, 199 Ordering data RF685R, 218 Accessories, 218 Parameter, 56 Polarization Circular, 64 Linear, 65 Portal configuration Application example, 43 Power supply RF640R, 138 RF670R, 185 Reader RF680M Features, 243 Functions, 244 Reading range Dependency of the, 52 Reciprocity, 58 reflections, 73 Reflections, 69 Return loss Definition, 63 RF600 Main applications, 31 RF620A Technical specifications, 270 RF620R reader Configuration, 103 SIMATIC RF600 522 System Manual, xx/2014, J31069-D0171-U001-A15-7618 Index Design, 90 Dimensions, 108 Interfaces, 103 Mounting types, Status display, 92, 115 RF630R reader Configuration, 119 Design, 113 Dimensions, 124 Interfaces, 119 Mounting types, RF640R reader Design, 129 Digital I/O interface, 132 Interfaces, 132, 138 LEDs, 131 Mounting types, Power supply, 138 RF650R mounting Antenna mounting kit, 170 RF650R reader CE Approval, 174 Design, 158 Digital I/O interface, 160 FCC information, 175 IC-FCB information, 176 LEDs, 160 Mounting types, RF660A Technical specifications, 326 RF660A antenna Radiation/reception characteristic for Europe (ETSI), 324 Radiation/reception characteristic for USA (FCC), 324 RF670R reader CE Approval, 194 Design, 177 Digital I/O interface, 180 FCC information, 196 IC-FCB information, 197 Interfaces, 160, 180, 185 LEDs, 179 Mounting types, Power supply, 185 RF680R mounting Antenna mounting kit, 209 RF680R reader CE Approval, 214 Design, 198 Digital I/O interface, 200 FCC information, 215 IC-FCB information, 216 Interfaces, 200 LEDs, 200 Mounting types, RF685R mounting Antenna mounting kit, 235 RF685R reader Design, 217 Digital I/O interface, 219 FCC information, 241 IC-FCB information, 242 Interfaces, 219 LEDs, 219 Mounting types, RF-MANAGER Levels of the automation/IT structure, 29 Safety Information, 21 Scalar product, 59 Securing the RF640R Antenna mounting kit, 148 Shielding, 85 Antenna cables, 70 Spurious lobes, 65 Status display of the RF620R reader, 92, 115 Structure of the RF620R reader, 90 Structure of the RF630R reader, 113 Tag standards, 243 Technical documentation On the Internet, 504 Technical Support, 504 Training, 505 Transponder Classes, 334 Generations, 334 how it works, 333 Improving detection, 73 UHF bands China, 76 Europe, USA, 78 SIMATIC RF600 System Manual, xx/2014, J31069-D0171-U001-A15-7618 523 Index Voltage standing wave ratio Definition, 63 VSWR Definition, 63 Wide-range power supply unit Pin assignment for DC outputs, 490 SIMATIC RF600 524 System Manual, xx/2014, J31069-D0171-U001-A15-7618
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : SIEMENS AG Create Date : 2014:07:01 12:25:39+02:00 Modify Date : 2014:07:01 12:26:22+02:00 Subject : System Manual Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2014:07:01 12:26:22+02:00 Creator Tool : Acrobat PDFMaker 10.1 für Word Format : application/pdf Title : SIMATIC RF600 Description : System Manual Creator : SIEMENS AG Document ID : uuid:eb9ccbbf-f113-48f7-b477-f38abd1d2f8d Instance ID : uuid:3695a394-3c90-4bbc-ba8d-7099a413af73 Producer : Adobe PDF Library 10.0 Page Count : 226EXIF Metadata provided by EXIF.tools