SPECIFICATIONSPage 1of 4Touchscreen —With the exception of power(ON/OFF), all controls are on-screentouchkeys; touch is sensed by infrared opticaldevices; optional controls include mouse andkeyboardWaveform Capacity —four, five, or sixwaveformsModule Capacity —90369 accepts oneUltraview or PCMS module internally and willsupport up to two additional modules using the90499 module housingParameter Capacity —18 parameters utilizingUltraview and PCMS modules as well asFlexport®interfacesTrends —24 hours of trend data can bedisplayedGraphic —1-, 2-, 6-,12- or 24-hour segments;data is stored in 1-minute resolutions (6-hoursegment is the default)Ultraview1050Monitor90369■Lightweight, compact, highly portable■Shares same touchscreen controls asother Ultraview Care Network™andPCMS™monitors of appropriate levels■Compatible with the full line ofUltraview Care Network and PCMSmodules■Large, 10.4-inch (26.42 cm), TFT colordisplay with 140° viewing angle■Data Shuttle®option allows up to 24hours of patient data to be transferredto other Ultraview Care Network andPCMS monitors■Advanced power management systemmaximizesbatteryperformanceduringtransport; includes battery“fuel-gauge”■Optional interactive bed-to-bedEthernet communication■Instant “Quicknet” 10BaseT Ethernetconnection■Optional wireless Ethernet withone tofive outbound waveformsand numericvital signs transmitted at2.4 GHz■Optional built-in 2-channel recorder■Optional mainstream EtCO2, O2,andMin CO2■Support for up to 250 nodes on anetwork with the Expanded NetworkfeaturePRINTERCONTROLSPREVIOUSMENUNORMALSCREENSPECIALFUNCTIONSALM MONITORSETUPRECORDHELP97 100SPO2ECG8569 bpm(80 )ECGNIBPII MON PACEDST =0.16A = 0 ROW 512040VIST =0.00%1166469LAST BP =11:4003/30mmHg150100S11:3211:3311:3411:3511:36110/ 69( 84)113/ 73( 88)113/ 69( 84)82/ 51( 64)108/ 67( 83)11:3711:3711:3811:3911:40110/ 73( 82)104/ 67( 79)114/ 73( 85)103/ 70( 78)116/ 64( 80)SUSPENDTM
SPECIFICATIONSUltraview1050Monitor90369Page 2of 4Tabular —Time increments of 1, 5, 10, 15, or30 minutes; 1, 1.5 or 3hours (1 hour is thedefault)Remote View/Alarm Watch —When equippedwith the Ethernet option, the 1050 provides awaveform display from aremote bedside ortelemetry patient on the Ultraview networkeither on request (Remote View) and/or inresponse to an alarm (Alarm Watch); the 1050provides awaveform display from up to 32selected beds; an Ultraview bedside monitorcan be remotely viewed by up to 16 networkdevices simultaneously (e.g., monitors,workstations)Display —Trace Height: 1.65 in (4.2 cm)2.36 in (6.0 cm)Sweep Speed: Avariety of speeds areavailable under modulecontrolEthernet Communication —10BaseTtelephone-style modular connector (RJ45)providedWireless Ethernet Capability —Provides2.4 GHz frequency-hopping spread-spectrumcommunication; the wireless Ethernet will sendone to five waveforms and numeric vital signsto the Ultraview Care NetworkColor TFT Display (TFT) —Resolution —640 by 480 pixelsSize —8.31 in (21.12 cm) wide6.24 in (15.84 cm) highSoftware Updates —Software updates includingnew features and capabilities are easilyupdated over the networkOptions —F — Ethernet interface, SDLC, audio I/O, video,alarm, serial; provides noninteractivebed-to-bed communicationH—Capnography, Ethernet interface, SDLC,audio I/O, video, alarm, serialN — Vital Signs CalculationsO — Drug Dose CalculationsP—Interactive Network Functions —Addsinteractive remote view and alarm watchcapabilities for parameters displayed fromremote bedsides and remote functionalityfor all trends (requiresoption For H)Q—Data Shuttle to transfer patient informationto another monitorR — Patient Data LoggerU — Dual Channel Internal RecorderZ — Wireless Ethernet Communication04 — Four waveforms05 — Five waveforms06 — Six waveformsELECTRICAL SPECIFICATIONSMains Power —Line voltage: 100-240 VAC;Frequency: 50-60 HzBatteries —Both sealed-lead acid (SLA) andSpacelabs Medical nickel metal hydride(NiMH) are supported. One or two 12 V(2.30Ah SLA or 2.45 Ah NiMH) batteries may beused, providing up to 2.0 hours of operation(TFT display) for up to 300 charge/dischargecycles with SLA and up to 2.5 hours ofoperation (TFT display) for up to 600 charge/discharge cycles with NiMH; operating time isdependent on configuration and usage; 1.5hours are required to charge batteries to 100%of capacity with AC connected to rear paneland mains switch in the OFF position, 3-hourcharge time required with the mains switch inthe ON positionPower Fail Backup —Will maintain patient datafor aminimum of three minutesIsolation —Chassis leakage current not greaterthan 300 µA(meets AAMI, UL2601-1,CSA #601.1 and IEC 601-1 standards)PHYSICAL DIMENSIONSHeight: 8.3 in (21.1 cm)Depth: 6.2 in (15.8 cm)Width: 11.7 in (29.7 cm)Weight: 10.0 Ibs (4.6 kg)DUAL CHANNEL INTERNAL RECORDER—Option UPrinting Method —Thermal array print headResolution —Eight dots per mm vertical and32 dots per mm horizontal at 25mm persecond sweep speedPaper —Heat-sensitive paper, 50mm wide x30m long, available in arollTraces —All monitored parameters, includingwaveforms and graphic trends, full annotationincludedFrequency Response —Determined by theparameter recordedChart Speed —1.56, 3.12, 6.25, 12.5, 25 and50mm per second (depending on the monitorsweep speed selected)Alarm Record —Records any parameters in analarm state when “Record on Alarm” is activeAuto Run —20 seconds or duration of alarmviolation (whichever is longer)
SPECIFICATIONS Ultraview1050Monitor90369Page 3of 4Controls —Continue, Slow, Stop, Unit OffIndicators —Paper Out, Unit OffRecord —Allows selection of up to two activemonitor channels plus trendsENVIRONMENTAL REQUIREMENTSStorage —Temperature: -13° to 140°F (-25° to 60°C)Humidity: 95% (non-condensing)Altitude: 0 to 40,000 ft (0 to 12,192 m)Operating —Temperature: 32° to 122°F (0° to 50°C)Humidity: 95% (non-condensing)Altitude: 0 to 15,000 ft (0 to 4,572 m)ELECTROMAGNETIC COMPATIBILITYEN60601-1-2, 1993-04Emissions — (CISPR 11) EN55011, Class BEN61000-3-2: HarmonicsEN6100-3-3: FlickerMil-Std-461D: RE101Immunity —IEC 1000-4-2: ESD, 8kV contact/15 kV airIEC 1000-4-3: RF Fields, 20 volts/meter,26 MHz to 1GHzIEC 1000-4-4: Burst, 1 kV data andI/O ports/2 kV power portsIEC 1000-4-5: Surge, 1kV differential/2kV common modeIEC 1000-4-6: Conducted RF, 3volt r.m.s.150 kHz to 80 MHzIEC1000-4-8: Magnetic Field (50/60 Hz),60 Amps/meterIEC 1000-4-11: Power quality, voltage andfrequency variationsMil-Std 461D: CS101, 12 volt r.m.s.10 kHz to 150 kHzMil-Std 461D: CS114, 120 dBµA10 kHz to 400 MHzREGULATORY APPROVALSETL listed and meets standard UL2601-1 forelectrical safety; approved by CSA; CEmarked in accordance with the Medical DeviceDirective, 93/42/EECACCESSORIES119-0251-01 100-240 volt AC converterNote: This AC converter ismandatory and is included atno charge146-0018-00 Rechargeable sealed-leadacid (SLA) battery146-0055-00 Rechargeable nickel metalhydride (NiMH) batteryNote: NiMH batteries requireunits with a minimum serialnumber of 369-1XXXXX. SLAbatteries may be used with allserial number units.010-1114-00 External sealed-lead acidbattery charger (notcompatible with NiMH batterypacks); recharges 1to 4removable SLA batteries;100-240 V016-0347-00 Wall mount016-0369-00 Bed rail mount (for 90369without capnography option)016-0369-01 Bed rail mount (for 90369 withcapnography option)016-0447-00 Roll Stand040-0992-00 Conversion Kit 10BaseT toAUI010-0609-00 MouseFor information about required supplies,please refer to the Spacelabs MedicalSupplies Products Catalog
Ultraview1050Monitor90369Spacelabs Medical, Inc.15220 N.E. 40th StreetP.O . Box 97013Redmond, WA 98073-9713Telephone: (425) 882-3700Fax: (425) 885-4877Telex: 4740085 SPL UIUltraview, Ultraview CareNetwork, PCMS, Data Shuttleand Flexport are trademarks ofSpacelabs Medical, Inc.Other brands and productnames are trademarks of theirrespective owners.All specifications are subject tochange without notice.www.spacelabs.com©Spacelabs Medical, Inc. 2001061-0750-00 Rev. M05/2001Page 4of 4

Navigation menu