Spacelabs Healthcare 010-0914-00 User Manual sl logo fh7
Spacelabs Healthcare, Inc. sl logo fh7
Contents
- 1. User Manual 1 of 3
- 2. User Manual 2 0f 3
- 3. User Manual 3 of 3
User Manual 2 0f 3
TM Ultraview 1050 Monitor 90369 II MON PACED ST = 0.16 A=0 ROW 5 120 40 69 VI ST = 0.00 11:32 11:33 11:34 11:35 11:36 110/ 113/ 113/ 82/ 108/ 69( 73( 69( 51( 67( 84) 88) 84) 64) 83) 11:37 11:37 11:38 11:39 11:40 110/ 104/ 114/ 103/ 116/ 73( 67( 73( 70( 64( 82) 79) 85) 78) 80) LAST BP = 11:40 03/30 Lightweight, compact, highly portable ■ Shares same touchscreen controls as other Ultraview Care Network™ and PCMS™ monitors of appropriate levels ■ Compatible with the full line of Ultraview Care Network and PCMS modules ■ Large, 10.4-inch (26.42 cm), TFT color display with 140° viewing angle HELP MONITOR SETUP ■ SPECIAL FUNCTIONS ALM SUSPEND ■ 69 bpm 97 100 ■ Advanced power management system maximizes battery performance during transport; includes battery “fuel-gauge” ■ Optional interactive bed-to-bed Ethernet communication ■ Instant “Quicknet” 10BaseT Ethernet connection ■ Optional wireless Ethernet with one to five outbound waveforms and numeric vital signs transmitted at 2.4 GHz ■ Optional built-in 2-channel recorder ■ Optional mainstream EtCO2, O2, and Min CO2 ■ Support for up to 250 nodes on a network with the Expanded Network feature RECORD % 85 116 64 ( 80 ) S 150 100 PREVIOUS MENU Data Shuttle® option allows up to 24 hours of patient data to be transferred to other Ultraview Care Network and PCMS monitors NORMAL SCREEN PRINTER CONTROLS SPECIFICATIONS Touchscreen — With the exception of power (ON/OFF), all controls are on-screen touchkeys; touch is sensed by infrared optical devices; optional controls include mouse and keyboard Waveform Capacity — four, five, or six waveforms Module Capacity — 90369 accepts one Ultraview or PCMS module internally and will support up to two additional modules using the 90499 module housing Parameter Capacity — 18 parameters utilizing Ultraview and PCMS modules as well as Flexport® interfaces Trends — 24 hours of trend data can be displayed Graphic — 1-, 2-, 6-,12- or 24-hour segments; data is stored in 1-minute resolutions (6-hour segment is the default) Page 1 of 4 Ultraview 1050 Monitor 90369 SPECIFICATIONS Tabular — Time increments of 1, 5, 10, 15, or 30 minutes; 1, 1.5 or 3 hours (1 hour is the default) Remote View/Alarm Watch — When equipped with the Ethernet option, the 1050 provides a waveform display from a remote bedside or telemetry patient on the Ultraview network either on request (Remote View) and/or in response to an alarm (Alarm Watch); the 1050 provides a waveform display from up to 32 selected beds; an Ultraview bedside monitor can be remotely viewed by up to 16 network devices simultaneously (e.g., monitors, workstations) Display — Trace Height: 1.65 in (4.2 cm) 2.36 in (6.0 cm) Sweep Speed: A variety of speeds are available under module control Ethernet Communication — 10BaseT telephone-style modular connector (RJ45) provided Wireless Ethernet Capability — Provides 2.4 GHz frequency-hopping spread-spectrum communication; the wireless Ethernet will send one to five waveforms and numeric vital signs to the Ultraview Care Network Color TFT Display (TFT) — Resolution — 640 by 480 pixels Size — 8.31 in (21.12 cm) wide 6.24 in (15.84 cm) high Software Updates — Software updates including new features and capabilities are easily updated over the network Options — F — Ethernet interface, SDLC, audio I/O, video, alarm, serial; provides noninteractive bed-to-bed communication H — Capnography, Ethernet interface, SDLC, audio I/O, video, alarm, serial N — Vital Signs Calculations O — Drug Dose Calculations P — Interactive Network Functions — Adds interactive remote view and alarm watch capabilities for parameters displayed from remote bedsides and remote functionality for all trends (requires option F or H) Q — Data Shuttle to transfer patient information to another monitor R — Patient Data Logger U — Dual Channel Internal Recorder Z — Wireless Ethernet Communication 04 — Four waveforms 05 — Five waveforms 06 — Six waveforms ELECTRICAL SPECIFICATIONS Mains Power — Line voltage: 100-240 VAC; Frequency: 50-60 Hz Batteries — Both sealed-lead acid (SLA) and Spacelabs Medical nickel metal hydride (NiMH) are supported. One or two 12 V (2.30 Ah SLA or 2.45 Ah NiMH) batteries may be used, providing up to 2.0 hours of operation (TFT display) for up to 300 charge/discharge cycles with SLA and up to 2.5 hours of operation (TFT display) for up to 600 charge/ discharge cycles with NiMH; operating time is dependent on configuration and usage; 1.5 hours are required to charge batteries to 100% of capacity with AC connected to rear panel and mains switch in the OFF position, 3-hour charge time required with the mains switch in the ON position Power Fail Backup — Will maintain patient data for a minimum of three minutes Isolation — Chassis leakage current not greater than 300 µA (meets AAMI, UL2601-1, CSA #601.1 and IEC 601-1 standards) PHYSICAL DIMENSIONS Height: Depth: Width: Weight: 8.3 in (21.1 cm) 6.2 in (15.8 cm) 11.7 in (29.7 cm) 10.0 Ibs (4.6 kg) DUAL CHANNEL INTERNAL RECORDER — Option U Printing Method — Thermal array print head Resolution — Eight dots per mm vertical and 32 dots per mm horizontal at 25mm per second sweep speed Paper — Heat-sensitive paper, 50mm wide x 30m long, available in a roll Traces — All monitored parameters, including waveforms and graphic trends, full annotation included Frequency Response — Determined by the parameter recorded Chart Speed — 1.56, 3.12, 6.25, 12.5, 25 and 50mm per second (depending on the monitor sweep speed selected) Alarm Record — Records any parameters in an alarm state when “Record on Alarm” is active Auto Run — 20 seconds or duration of alarm violation (whichever is longer) Page 2 of 4 SPECIFICATIONS Controls — Continue, Slow, Stop, Unit Off Indicators — Paper Out, Unit Off Record — Allows selection of up to two active monitor channels plus trends ACCESSORIES 119-0251-01 100-240 volt AC converter Note: This AC converter is mandatory and is included at no charge 146-0018-00 Rechargeable sealed-lead acid (SLA) battery 146-0055-00 Rechargeable nickel metal hydride (NiMH) battery Note: NiMH batteries require units with a minimum serial number of 369-1XXXXX. SLA batteries may be used with all serial number units. 010-1114-00 External sealed-lead acid battery charger (not compatible with NiMH battery packs); recharges 1 to 4 removable SLA batteries; 100-240 V ENVIRONMENTAL REQUIREMENTS Storage — Temperature: -13° to 140°F (-25° to 60°C) Humidity: 95% (non-condensing) Altitude: 0 to 40,000 ft (0 to 12,192 m) Operating — Temperature: 32° to 122°F (0° to 50°C) Humidity: 95% (non-condensing) Altitude: 0 to 15,000 ft (0 to 4,572 m) ELECTROMAGNETIC COMPATIBILITY EN60601-1-2, 1993-04 Emissions — (CISPR 11) EN55011, Class B EN61000-3-2: Harmonics 016-0347-00 Wall mount EN6100-3-3: Flicker 016-0369-00 Mil-Std-461D: RE101 Bed rail mount (for 90369 without capnography option) 016-0369-01 Bed rail mount (for 90369 with capnography option) 016-0447-00 Roll Stand 040-0992-00 Conversion Kit 10BaseT to AUI Mouse Immunity — IEC 1000-4-2: ESD, 8 kV contact/15 kV air IEC 1000-4-3: RF Fields, 20 volts/meter, 26 MHz to 1 GHz IEC 1000-4-4: Burst, 1 kV data and I/O ports/2 kV power ports 010-0609-00 IEC 1000-4-5: Surge, 1 kV differential/ 2 kV common mode IEC 1000-4-6: Conducted RF, 3 volt r.m.s. 150 kHz to 80 MHz For information about required supplies, please refer to the Spacelabs Medical Supplies Products Catalog IEC1000-4-8: Magnetic Field (50/60 Hz), 60 Amps/meter IEC 1000-4-11: Power quality, voltage and frequency variations Mil-Std 461D: CS101, 12 volt r.m.s. 10 kHz to 150 kHz Mil-Std 461D: CS114, 120 dBµA 10 kHz to 400 MHz REGULATORY APPROVALS ETL listed and meets standard UL2601-1 for electrical safety; approved by CSA; CE marked in accordance with the Medical Device Directive, 93/42/EEC Page 3 of 4 Ultraview 1050 Monitor 90369 Ultraview 1050 Monitor 90369 Spacelabs Medical, Inc. 15220 N.E. 40th Street P.O. Box 97013 Redmond, WA 98073-9713 Telephone: (425) 882-3700 Fax: (425) 885-4877 Telex: 4740085 SPL UI Ultraview, Ultraview Care Network, PCMS, Data Shuttle and Flexport are trademarks of Spacelabs Medical, Inc. Other brands and product names are trademarks of their respective owners. All specifications are subject to change without notice. www.spacelabs.com © Spacelabs Medical, Inc. 2001 061-0750-00 Rev. M 05/2001 Page 4 of 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2001:05:11 14:43:25Z Creator : FreeHand 7.0 Modify Date : 2002:04:12 14:32:43-06:00 Page Count : 4 Creation Date : 2001:05:11 14:43:25Z Producer : Acrobat Distiller 4.0 for Windows Mod Date : 2002:04:12 14:32:43-06:00 Metadata Date : 2002:04:12 14:32:43-06:00 Title : sl_logo.fh7EXIF Metadata provided by EXIF.tools