SPECIFICATIONS ML-2499-BYGA2-0! 2.4 - 2.5 Gllz Antenna Model ML-2499'BYGA2'01 “shining Arres'er and Cable Assemblies Frequency MHz 24002500 ASSEMBLY AND INSTALLATION Gain: 13.9 dBi ' Number Elements: 15 Front-toBack Ratio: 18 dB E—Flane (3 dB beamwidth): 30° H—Flane (3 dB beamwidth): 34° "Radiating Element Brass Impededance (Ohms): 50 Antenna Conneclon Type N (n Antenna Weight lb. (kg): 1.25 (56) Mounting: Articulating mount Dimensions in.(cm): ZS-IIZ X 3-314 x 1~112(S7.3 x 9.5 X 3.8) Enclosure: UV Stable Polycarbonate Mast Diameter Max. in (cm): 2—118 (5.4) Antenna Cable in (cm): 12 (30.5) Important Wanting: Two pails of weep holes are provided in the radome one for vertical mounting and one for horizontal mDunling. You must fill Ihe unused pair of weep holes with adhesive dots prior to mounting or unwanted leakage into the radome may result {see instructions), APPLICATION "7 The ML-2499—BYGA2—01 is a complete kit consisting of a highly directional iselement Yagi enclosed in a UV stable weatherproof radome. This antenna providfi extended point- to-point link coverage. or sharply focused zonal coverage for 2.4-GHz ISM applications SAFETYa The ML»2499~BYGA2—01 and all associated equipment should be installed in accordance with applicable local and national electrical code guidelines to ensure safe operation. ANTENNA LOCATION The antenna may be mounted at interioforexbfiorlocations. For link installations. a “neat-sight path between antennas works best. Although 2.4 GHZ signals penetrate cubical dividers and interior partitions with little attenuation, reinforwd block walls, banks of metal cabinets, or steel shelving may attenuate signals or cause multipath, a condition where reflected signals interfere with the primary signal. Because antenna beam width Is restricted to 15degrees each side of center. the P0241SSNA must be aimed accurately during installation in order to provide optimum gain and best performance. GENERAL MOUNTING INFORMATION - The P0241 SSNA is equipped with an articulating mount, gifg'nififii'y'm‘?“ Inc' and may be oriented for vertical or horizontal polarization. lt Huntsville, Nv11742-1aoo accommodates mast sizes up to 2-1I8»inches (4.76 cm). 951533 310: WEEP HOLES Two sets of weep holes are provided in the P6241 5NA radome one set is required for horizontal mounting and one set for vertical mounting. Prior to installation, the unused pair of weep holes must be plugged with adhesive dots to prevent leakage. Two small adhesive dots are supplied with each antenna for this purpose. Weep-hole locations are shown in Figure-A. 1.Vertical Mounting: When mounting vertically, find two weep holes on the broad flat side of the radome and cover with adhesive dots 2. Horizontal Mounting. When mounting honzontally, find two (2) weep holes on the narrow edge of the radome and cover with adhesive dots. When adhesive dots are applied check to ensure holes are fully closed FIGURE A Coax Routing: During installation, avoid any sharp bend or kink in the feed line. Also, avoid bending coax close to the radome where it may apply pressure to the wall of the cable grommet and compromise the water seal. Route coax downward—or provide a drip loop to ensure rainwater accumulating on the jacket flows away from the cable grommet in the radome. ASSEMBLY 1. Prior to mounting, find the arrow sticker on the radome. When mounting vertically, the arrow should always point upward. When mounting horizontally. the arrow sticker should always be on top of the radome. This positioning is required (a) to ensure weep holes fall on the bottom of the antenna. and (b) to ensure proper phasing when multiple antennas are used with a harness. nouns B” ASSEMBLY cont. 2. Orient for the desired polarization and install the antenna base against the mast using the two U-bolts (04), four hex nuts (18), four lock washers (19) and two V-blooks (63) provided in hardware kit 3. If the antenna has an articulating mount, install the antenna ball into position and tilt tor the desired elevation angle (Figure-D). Tighten the socket screw with the supplied wrench. 4. Rotate antenna to the desired directional position and tighten all hardware. FIGURE C FIGURE D System grounding and lightning protection are essential especially for exterior-mounted antennas exposed to the elements (refer to the National Electrical Code). Never install an antenna where it may fall and contact electrical lines. KEY Pm DISPLAY SIZE U—BOLT 5115215 x 3-114’ x 2-7/rs' 010115 55 HEX sits' 18 owns SPLlTLOCK 5115‘ WASHER 195725 . v anACKEr 3 t ADHESIVE JUMPER KIT INSTALLATION (OPTIONAL) The jumper and arrester kits provide a convenient way to set up your link. For best results. tighten connectors securely and encapsulate exterior junctions with sealant tape. When routing cable. use drip loops to guide rain water away from the LAC4 and back of the antenna CANM1ZBRENMLA The Cushcraft lightning arrester kit has been designed to provide in—Iine lightning protection and can be easily integrated into the Cushcraft extension cable jumper system. The pre-made low loss cable assembly features high quality cable and N male connectors and easy to use connector wraps. It offers the user a fast, convenient method to remotely mount the antenna at a distance of up to 100 feet from the access point or bridge. CANMGOOLNM 7 énsnnaoufnh 245er CASNMtZODNM 10m E‘AsnM‘ofiNM‘ Jolt. CASNMBOONM soft. Figure E LAC4 Installation on PC24158NA CANM600LNM (50 ft) . Brldgel - an L009s “i Access Polnt \. f Sealant_ \ l Tape LAC4 LIGHTNING ARRESTER (OPTIONAL) For best results, install the LAC4 in close proximity to a low-resistance ground at a point where the coaxial cable enters the building (see Photo-1). in most cases, one B—foot rod driven into moist soil—or multiple mds bonded together will provide adequate grounding (see National Electrical Code guidelines) To connect the LAC4 to ground, use a very short and direct run of #10 solid copper wire (or equivalent) For exterior installations, weatherproof coax connectors with a suitable mastic or mbberized tape to prevent water incursion (see Photo1). Be sure to install in an accessible location that permits periodic inspection and (as needed) replacement of the gas cartridge. Provide drip loops in cables to prevent water from entering the building (see Photo 2). Photo 1 ‘L/ Sealant Tape , r or Rubberized Protestant Photo 2 v, Drip Loops fit /I' ‘i \\ Important Note: A good ground system is essential for proper operation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 3 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:45fd4302-e784-44d7-96b4-a319c1b6ab8c Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2004:09:08 17:22:13+08:00 Create Date : 2004:09:08 17:19:50+08:00 Metadata Date : 2004:09:08 17:22:13+08:00 Document ID : uuid:707e59bb-30d2-43ee-b4ab-787f3bde9b3c Format : application/pdf Title : 1.jpg Creator : Agaren Yang Author : Agaren YangEXIF Metadata provided by EXIF.tools