Symbol Technologies WSAP5100 WLAN Access Port User Manual AP300iQIGver13 11x17

Symbol Technologies Inc WLAN Access Port AP300iQIGver13 11x17

revised users manual 1

Download: Symbol Technologies WSAP5100 WLAN Access Port User Manual AP300iQIGver13 11x17
Mirror Download [FCC.gov]Symbol Technologies WSAP5100 WLAN Access Port User Manual AP300iQIGver13 11x17
Document ID470831
Application IDl5vg2vYrazte+gGksbHgfA==
Document Descriptionrevised users manual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize29.71kB (371333 bits)
Date Submitted2004-09-21 00:00:00
Date Available2004-09-08 00:00:00
Creation Date2004-09-17 12:39:08
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2004-09-17 12:39:08
Document TitleAP300iQIGver13_11x17.fm
Document CreatorPScript5.dll Version 5.2
Document Author: mstocksiek

(4)
(5)
• One RJ-45 connector
• LED indicators
• Safety wire tie point
• Kensington-compatible lock port
• Slots for wall mounting
• Clips for mounting on a suspended ceiling T-bar
Features
(6)
Task
802.11a Activity LED Amber
802.11b/g Activity LED Green
Booting
The amber LED flashes three times per second
until firmware is loaded. During boot, 802.11a
mobiles cannot associate.
After adoption, the amber LED is steady or
flashes with 802.11a radio traffic.
The amber LED flashes once per second
if an error prevents the 802.11a radio from
operating normally.
The green LED flashes three times per second
until firmware is loaded. During boot,
802.11b/g mobiles cannot associate.
After adoption, the green LED is steady or
flashes with 802.11b/g radio traffic.
The green LED flashes once per second
if an error prevents the 802.11b/g radio from
operating normally.
Error
Normal
LED Indicators
Transmit and receive
4.9 to 5.875 range
802.11b/g
1, 2, 5.5, 11 CCK
6, 9, 12, 18, 24, 36, 48, 54 ODFM
Transmit and receive
2.4 to 2.5 ISM range
The AP 300 Access Port, a component of the Symbol Wireless Switch System, links wireless
802.11a/b/g devices to the switch, enabling growth of your wireless network with a costeffective alternative to standard access points. The AP 300 Access Port provides two
placement options: wall and ceiling. Wall mount slots fit onto two screws provided. Arrows on
the case guide placement of the screws. Clips on the back of the case fit onto a suspended
ceiling T-bar.
The AP 300 Access Port is an IEEE 802.11-compliant device containing one 802.11a radio and
one 802.11b/g radio. The following table lists radio characteristics for each radio’s compliance.
The three supported 802.11g modes are simultaneous CCK and ODFM. CCK only, or ODFM only.
GHz
Service Information
© 2004 SYMBOL TECHNOLOGIES, INC. All rights reserved.
Before using the unit, it must be configured to operate in the facility’s network and run your
applications. If you have a problem running your unit or using your equipment, contact your
facility’s Technical or Systems Support. If there is a problem with the equipment, they will
contact the Symbol Support Center:
Austria/Österreich
1-800-672-906
Australia
Asia/Pacific
0800 328 2424
United Kingdom
Canada
1-800-653-5350
1-631-738-2400
United States
905-629-7226
6074-49020
Germany/Deutschland
01-40-96-52-21
9 5407 580
Finland/Suomi
7020-1718
Denmark/Danmark
1-505-5794-0
91 324 40 00
Inside Spain
+34 91 324 40 00
Outside Spain
Spain/España
+47 2232 4375
Norway/Norge
5-520-1835
Contact local distributor or call
+44 118 945 7360
Europe/Mid-East
Distributor Operations
1-800-347-0178 Inside US
+1-954-255-2610 Outside US
Latin America
Sales Support
84452900
Sweden/Sverige
AP 300 Access Port
Quick Installation Guide
802.11a/b/g Access Port Internal Antenna Model
WSAP-5110-100-WW
+65-6796-9600
Mexico/México
2-484441
Italy/Italia
France
11-8095311
Utilizing Diversity
315-271700
Mbps Data Rate Support
Netherlands/Nederland
Device
The lock port, compatible with Kensington-style security cables, is on the side of the case.
Lock Port
firmware downloaded from the switch can be updated via the Ethernet interface from the
Wireless Switch.
South Africa
(3)
Motherboard firmware enables the unit to boot after either a power up or a watchdog reset.
After self-boot, the motherboard sends an “I am alive” message into the network to be adopted
and loaded with the actual runtime code. The boot firmware on the motherboard and the
The AP 300 Access Port comprises two 802.11 radios: an 802.11b/g radio operating in
the 2.4 to 2.5Ghz band and an 802.11a radio operating in the 4.9 to 5.875Ghz band. Each radio
has an embedded controller which runs local firmware used to perform the functions of the
lower 802.11 MAC. All upper MAC functions and MAC management are controlled by the
Wireless Switch.
The AP 300 Access Port has one RJ-45 connector supporting an 10/100 Ethernet port and
requires 802.3af-compliant power from an external source.
24.1cm (9.5in.)
17.8cm (7.0in.)
5.1cm (2.0in.)
0.45kg (1.0lbs)
The AP 300 Access Port is an IEEE 802.11-compliant device containing one 802.11a radio and
one 802.11b/g radio. The unit contains internal 2.4-2.5GHz and 4.9-5.285GHz antennas and
supports UNII band 1, and it requires power from any UL-listed, 802.3af-compatible Power Over
Ethernet (PoE) power source.
Description
The unit has LED activity indicators on the front of the case provide a status display indicating
error conditions, transmission, and network activity for the 802.11a (amber) radio or the
802.11b/g (green) radio.
• AP 300 Access Port
• Two screws
• Two wall anchors
• Quick Installation Guide
AP 300 Access Port Package Contents
6, 9, 12, 18, 24, 36, 48, 54
Radio Characteristics
Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan);
No part of this publication can be modified or adapted in any way, for any purposes without
permission in writing from Symbol Technologies (Symbol). The material in this manual is
subject to change without notice. Symbol reserves the right to make changes to any product to
improve reliability, function, or design.
Symbol does not assume any product liability arising out of, or in connection with, the
application or use of any product, circuit, or application described herein.
No license is granted, either expressly or by implication, estoppel, or otherwise under any
Symbol Technologies, Inc., intellectual property rights. No license is granted, either expressly
or by implication, estoppel, or otherwise under any patent right or patent, covering or relating
to any combination, system, apparatus, machine, material, method, or process in which
Symbol products might be used. An implied license exists only for equipment, circuits, and
subsystems contained in Symbol products.
Symbol and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other
product names mentioned in this manual may be trademarks or registered trademarks of their
respective companies and are hereby acknowledged.
Symbol Technologies, Inc.
One Symbol Plaza
Holtsville, N.Y. 11742-1300
http://www.symbol.com
Patents
This product is covered by one or more of the following U.S. and foreign Patents:
4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,760,248; 4,806,742; 4,816,660;
4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183;
5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149;
5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553;
5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788;
5,306,900; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081;
5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949;
5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610;
5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028;
5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851;
5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731;
5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,848,064; 5,850,078;
5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059;
5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,029,894: 6,031,830;
6,036,098; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,082,621; 6,084,528; 6,088,482;
6,092,725; 6,101,483; 6,102,293; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180;
6,142,379; 6,172,478; 6,176,428; 6,178,426; 6,186,400; 6,188,681; 6,209,788; 6,209,789; 6,216,951; 6,220,514;
6,243,447; 6,244,513; 6,247,647; 6,308,061; 6,250,551; 6,295,031; 6,308,061; 6,308,892; 6,321,990; 6,328,213;
6,330,244; 6,336,587; 6,340,114; 6,340,115; 6,340,119; 6,348,773; D305,885;
For the latest version of this guide go to: http://www.symbol.com/manuals
D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581;
D414,171; D414,172; D418,500; D419,548; D423,468; D424,035; D430,158; D430,159; D431,562; D436,104; 5,912,662;
6,011873; 6,080,001; 6,234,389; 6,193,152B1;
72-69572-01
Revision 2 September 2004
Length
Width
Height
Weight
Dimensions & Weight
Operating Voltage
48VDC typical; 36-57VDC range
Operating Current
100mA to 165mA
Peak Current
250mA
Operating Temperature
0°C to 40°C (32°F to 104°F)
Operating Humidity
5% to 95% non-condensing
Operating Altitude (max )
2438m (8,000ft.)
Storage Temperature
-40°C to 70°C (-40°F to 158°F)
Storage Humidity
85%
Storage Altitude (max.)
4572m (15,000ft.)
Drop
91cm (36in.) to concrete
Electrostatic Discharge
+/-15kV air; +/-8kV contact; +/-2kV pin
Note: The AP 300 Access Port (WSAP-5110-100-WW) supports UNII band 1.
Technical Specifications
The AP 300 Access Port receives all power and transfers data through the same CAT-5 cable.
There is no additional power supply required.
802.11a
Introduction
European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713rev. 07/04
Warranty
(A) Warranty Symbol Technologies (hereafter “Seller”) hardware Products are warranted against defects in workmanship and
materials for a period of twelve (12) months from the date of shipment, unless otherwise provided by Seller in writing, provided
the Product remains unmodified and is operated under normal and proper conditions. Warranty provisions and durations on
software, integrated installed systems, Product modified or designed to meet specific customer specifications (“Custom
Products”), remanufactured products, and reconditioned or upgraded products, shall be as provided in the applicable Product
specification in effect at the time of purchase or in the accompanying software license.
(B) Spare Parts Spare parts (i.e. parts, components, or subassemblies sold by Seller for use in the service and maintenance
of Products) are warranted against defects in workmanship and materials for a period of thirty (30) days from the date of
shipment. Spare parts may be new or originate from returned units under the conditions set forth in subsection D below.
(C) Repair of Symbol-branded hardware For repairs on Symbol-branded hardware Products under this Agreement,
including repairs covered by warranty, the repair services provided are warranted against defects in workmanship and
materials on the repaired component of the Product for a period of thirty (30) days from the shipment date of the repaired
Product, or until the end of the original warranty period, whichever is longer.
(D) Product Service Products may be serviced or manufactured with parts, components, or subassemblies that originate from
returned products and that have been tested as meeting applicable specifications for equivalent new material and Products.
The sole obligation of Seller for defective hardware Products is limited to repair or replacement (at Seller’s option) on a “return
to service depot” basis with prior Seller authorization. Customer is responsible for shipment to the Seller and assumes all costs
and risks associated with this transportation; return shipment to the Customer will be at Seller's expense. Customer shall be
responsible for return shipment charges for product returned where Seller determines there is no defect (“No Defect Found”),
or for product returned that Seller determines is not eligible for warranty repair. No charge will be made to Buyer for
replacement parts for warranty repairs. Seller is not responsible for any damage to or loss of any software programs, data or
removable data storage media, or the restoration or reinstallation of any software programs or data other than the software,
if any, installed by Seller during manufacture of the Product.
(E) Original Warranty Period Except for the warranty applying solely to the repaired component arising from a repair service
as provided in Section C above, the aforementioned provisions do not extend the original warranty period of any Product that
had either been repaired or replaced by Seller.
(F) Warranty Provisions The above warranty provisions shall not apply to any Product (i) which has been repaired, tampered
with, altered or modified, except by Seller’s authorized service personnel; (ii) in which the defects or damage to the Product
result from normal wear and tear, misuse, negligence, improper storage, water or other liquids, battery leakage, use of parts
or accessories not approved or supplied by Symbol, or failure to perform operator handling and scheduled maintenance
instructions supplied by Seller; (iii) which has been subjected to unusual physical or electrical stress, abuse, or accident, or
forces or exposure beyond normal use within the specified operational and environmental parameters set forth in the
applicable Product specification; nor shall the above warranty provisions apply to any expendable or consumable items, such
as batteries, supplied with the Product.
EXCEPT FOR THE WARRANTY OF TITLE AND THE EXPRESS WARRANTIES STATED ABOVE, SELLER DISCLAIMS ALL
WARRANTIES ON PRODUCTS FURNISHED HEREUNDER INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR USE. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED IN DURATION
TO THE LIMITED WARRANTY PERIOD. SOME STATES OR COUNTRIES DO NOT ALLOW A LIMITATION ON HOW LONG AN
IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR
CONSUMER PRODUCTS. IN SUCH STATES OR COUNTRIES, FOR SUCH PRODUCTS, SOME EXCLUSIONS OR LIMITATIONS OF
THIS LIMITED WARRANTY MAY NOT APPLY.
The stated express warranties are in lieu of all obligations or liabilities on the part of Seller for damages, including but not
limited to, special, indirect or consequential damages arising out of or in connection with the use or performance of the Product
or service. Seller’s liability for damages to Buyer or others resulting from the use of any Product or service furnished hereunder
shall in no way exceed the purchase price of said Product or the fair market value of said service, except in instances of injury
to persons or property.
(1)
(2)
Installation Instructions
9.
The AP 300 Access Port mounts either on a wall with wide-shoulder screws or on a suspended
ceiling T-bar. This unit is not designed for mounting on a desk.
To prepare for installation, perform the following steps:
1.
Match the model number on the purchase order with the model numbers in the packing
list and on the case of the device shipped.
2.
Verify that the contents of the box include the intended AP 300 Access Port and
mounting hardware:
3.
4.
Item
Notes
WSAP-5110-100-WW
802.11a/b/g configuration.
Mounting Hardware: Two wide-shoulder Phillips pan head self-tapping
screws.
Verify the unit has power by observing that the LEDs are lit or flashing.
Suspended Ceiling T-Bar Mount
CE Marking and European Economic Area (EEA)
Regulatory Information
Ceiling mount requires holding the AP 300 Access Port up against a T-bar of a suspended ceiling
grid and twisting the case onto the T-bar.
All Symbol devices are designed to be compliant with rules and regulations in locations they are
sold and will be labeled as required. Any changes or modifications to Symbol Technologies
equipment, not expressly approved by Symbol Technologies, could void the user’s authority to
operate the equipment.
Ceiling Mount Hardware
• Safety wire (recommended) and security cable (optional)
Use only the approved antennas. Unauthorized antennas, modifications, or attachments could
cause damage and may violate regulations.
Ceiling Mount Procedure
This device is to be used only with Symbol Technologies Wireless Switch.
1.
If required, loop a safety wire—with a diameter of at least .101cm (.04in.) but no more
than .158cm (.0625in.) —through the tie post and secure the loop.
2.
If required, install and attach a security cable to the lock port.
3.
Plug the Ethernet cable into the the unit and to a switch with an 802.3af-compatible
power source.
Review site survey and network analysis reports to determine the location and
mounting position for the AP 300 Access Port.
Connect a CAT-5 cable to a compatible 802.3af power source and run the cable to the
installation site. Ensure that there is sufficient slack on the cable to perform the
installation steps.
Wall Mount
This mounting requires hanging the AP 300 Access Port along its width or length using the two
slots on the bottom of the unit. The AP 300 can be mounted onto any plaster, wood, or cement
wall surface using the provided wall anchors when necessary. The illustration shows a
lengthwise mount.
Country Approvals
Regulatory markings are applied to the device signifying the radio (s) are approved for use in the
following countries: United States, Canada, Australia, Japan & Europe 1,2. Please refer to the
Symbol Declaration of Conformity (DoC) for details of other country markings. This is available at
http://www2.symbol.com/doc/.
Note 1: For 2.4GHz Products: Europe includes, Austria, Belgium, Croatia, Czech Republic, Croatia, Cyprus, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Slovak Republic, Slovenia, Spain, Sweden, Switzerland, and the United Kingdom.
Note 2: The use of 5GHz RLAN’s has varying restrictions of use; please refer to the Symbol Declaration of Conformity (DoC) for details.
The use of 2.4GHz RLAN’s, for use through the EEA, have the following restrictions:
• Maximum radiated transmit power of 100 mW EIRP in the frequency range 2.400 -2.4835
GHz
• France, outside usage is restricted to 2.4-2.454 GHz
• Belgium, outside usage is restricted to 2.460-2.4835 GHz
• Italy requires a user license for outside usage.
The use of 5GHz RLAN’s has varying restrictions for use within the EEA; please refer to the
Symbol Declaration of Conformity (DoC) for details at http://www2.symbol.com/doc/
Statement of Compliance
Symbol Technologies, Inc., hereby, declares that this device is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC. A Declaration of
Conformity may be obtained from
http://www2.symbol.com/doc/
Other Countries
Mexico - Restrict Frequency Range to: 2.450 - 2.4835 GHz.
Sri Lanka - Restrict Frequency Range to: 2.400 – 2.430 GHz.
Operation of the device without regulatory approval is illegal.
Frequency of Operation
4.
Face the bottom of the T-bar with the back of the case.
5.
Orient the case by its length and the length of the T-bar.
6.
Rotate the case in place 45 degrees clockwise, or about 10 o’clock.
7.
Push the back of the case onto the bottom of the T-bar.
The use on UNII (Unlicensed National Information Infrastructure) Band 1 5150-5250 MHz is restricted to indoor
use only.
FCC/EU RF Exposure Guidelines
Safety Information
The device complies with Internationally recognised standards covering Specific Absorption Rate
(SAR) related to human exposure to electromagnetic fields from radio devices. It is advisable to
use the device only in the normal operating position.
Remote and Standalone Antenna Configurations
To comply with FCC RF exposure requirements, antennas that are mounted externally at remote
locations or operating near users at stand-alone desktop or similar configurations must operate
with a minimum separation distance of 20 cm from all persons.
(7)
(9)
Wall Mount Hardware
• Two wide-shoulder Phillips pan head self-tapping screws
• Two wall anchors
• Safety wire (recommended) and security cable (optional)
Note:
In the event that the original mounting screws are lost, the following screws
can be used instead:`(ANSI Standard) #6-18 X 0.875in. Type A or AB Self-Tapping Screw, or (ANSI Standard Metric) M3.5 X 0.6 X 20mm Type D Self-Tapping
Screw
8.
Rotate the case 45 degrees counter-clockwise. The clips click as they fasten to the T-bar.
Orient the case on the wall by its width or length.
2.
Using the arrows on one edge of the case as guides, move the edge to the midline of
the mounting area and mark points on the midline for the screws.
9.
Verify the unit has power by observing the LEDs.
3.
At each point, drill a hole in the wall, insert an anchor, screw into the anchor the wall
mounting screw and stop when there is 1mm between the screw head and the wall.
Note:
When pre-drilling a hole the recommended hole size is 2.8mm (0.11in.) if the
screws are going directly into the wall and 6mm (0.23in.) if the provided wall
anchors are being used.
(13)
Power Supply
Customer Support
This device is powered from a 802.3af compliant power source which is UL approved.
Symbol Technologies provides its customers with prompt and accurate customer support. Use
the Symbol Support Center as the primary contact for any technical problem, question or
support issue involving Symbol products.
Radio Frequency Interference Requirements
Wall Mount Procedure
1.
(11)
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
• Consult the dealer or an experienced radio/TV technician for help.
If the Symbol Customer Support specialists cannot solve a problem, access to all technical
disciplines within Symbol becomes available for further assistance and support. Symbol
Customer Support responds to calls by e-mail, telephone or fax within the time limits set forth
individual contractual agreements.
When contacting Symbol Customer Support, please provide the following information:
• Device serial number
• Product name or model number
• Software type and version number
North American Contacts
Inside North America, contact Symbol at:
Symbol Technologies, Inc.
One Symbol Plaza
Holtsville, New York 11742-1300
Radio Transmitters (Part 15)
4.
If required, loop a safety wire—with a diameter of at least .101cm (.04in.) but no more
than .158cm (.0625in.)—around the tie point and secure the loop.
5.
If required, install and attach a security cable to the unit’s lock port.
6.
Attach the Ethernet cable to the unit and to a switch with an 802.3af-compatible power
source.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Radio Frequency Interference Requirements – Canada
For warranty and service information, contact the Symbol Support Center: telephone 1-631738-6213 or 1-800-653-5350; fax: (631) 563-5410; or E-mail: support@symbol.com.
This Class B digital apparatus complies with Canadian ICES-003.
Web Support Sites and Additional Information
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Radio Transmitters
This device complies with RSS 210 of Industry & Science Canada. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference and (2) this device
must accept any interference received, including interference that may cause undesired operation.
Label Marking: The Term “IC:” before the radio certification only signifies that Industry Canada
technical specifications were met.
7.
Place the middle of each of the case’s mount slots over the screw heads.
8.
Slide the case down along the mounting surface to hang the mount slots on the screw
heads.
(8)
(10)
1-631-738-2400/1-800-SCAN 234
Fax: 1-631-738-5990
International Contacts
Outside North America, contact Symbol at:
Symbol Technologies, Inc.
Symbol Place
Winnersh Triangle, Berkshire, RG41 5TP
United Kingdom
0800-328-2424 (Inside UK) /+44 118 945 7529 (Outside UK)
(12)
MySymbolCare
Symbol Services Homepage
Symbol Software Updates
Symbol Developer Program
Symbol Knowledge Base
http://www.symbol.com/services/msc/
http://symbol.com/services/
http://symbol.com/services/downloads/
http://software.symbol.com/devzone/
http://kb.symbol.com/register.asp
Obtain additional information by contacting Symbol at:
• 1-800-722-6234, inside North America
• +1-631-738-5200, in/outside North America
• http://www.symbol.com/
(14)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:c2b02258-b721-43fb-b167-c46b9d733ddf
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Create Date                     : 2004:09:17 12:39:08-07:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2004:09:17 12:39:08-07:00
Document ID                     : uuid:7d5ad571-a814-4086-950b-8a2d1b8cb8dc
Format                          : application/pdf
Title                           : AP300iQIGver13_11x17.fm
Creator                         : mstocksiek
Author                          : mstocksiek
EXIF Metadata provided by EXIF.tools
FCC ID Filing: H9PWSAP5100

Navigation menu