Symbol Technologies WSAP5100 WLAN Access Port User Manual AP300QIGver13 11x17
Symbol Technologies Inc WLAN Access Port AP300QIGver13 11x17
Contents
- 1. users manual 1
- 2. users manual 2
- 3. installation manual
- 4. revised users manual 1
- 5. revised users manual 2
revised users manual 2
(4) (5) (6) 802.11a Activity LED Amber 802.11b/g Activity LED Green The amber LED flashes three times per second until firmware is loaded. During boot, 802.11a mobiles cannot associate. After adoption, the amber LED is steady or flashes with 802.11a radio traffic. The amber LED flashes once per second if an error prevents the 802.11a radio from operating normally. The green LED flashes three times per second until firmware is loaded. During boot, 802.11b/g mobiles cannot associate. After adoption, the green LED is steady or flashes with 802.11b/g radio traffic. The green LED flashes once per second if an error prevents the 802.11b/g radio from operating normally. Normal The AP 300 Access Port is an IEEE 802.11-compliant device containing one 802.11a radio and one 802.11b/g radio. The following table lists radio characteristics for each radio’s compliance. The three supported 802.11g modes are simultaneous CCK and ODFM, CCK only, or ODFM only. Error 23.5cm (9.25in.) 14.6cm (5.75in.) 2.54cm (1.0in.) 0.73kg (1.6lbs) Motherboard firmware enables the unit to boot after either a power up or a watchdog reset. After self-boot, the motherboard sends an “I am alive” message into the network to be adopted and loaded with the actual runtime code. The boot firmware on the motherboard and the firmware downloaded from the switch can be updated via the Ethernet interface from the Wireless Switch. The AP 300 Access Port comprises two 802.11 radios: an 802.11b/g radio operating in the 2.4 to 2.5Ghz band and an 802.11a radio operating in the 4.9 to 5.875Ghz band. Each radio has an embedded controller which runs local firmware used to perform the functions of the lower 802.11 MAC. All upper MAC functions and MAC management are controlled by the Wireless Switch. The AP 300 Access Port has one RJ-45 connector supporting an 10/100 Ethernet port and requires 802.3af-compliant power from an external source. The unit has LED activity indicators on the front of the case for a wall mount. With the unit mounted above a ceiling, LEDs are at the center of an oval badge on the ceiling; a light pipe enables viewing the back LEDs through the ceiling tile. LED Indicators Service Information © 2004 SYMBOL TECHNOLOGIES, INC. All rights reserved. Before using the unit, it must be configured to operate in the facility’s network and run your applications. If you have a problem running your unit or using your equipment, contact your facility’s Technical or Systems Support. If there is a problem with the equipment, they will contact the Symbol Support Center: Austria/Österreich 1-800-672-906 Australia Asia/Pacific 0800 328 2424 United Kingdom Canada 1-800-653-5350 1-631-738-2400 United States 905-629-7226 6074-49020 Germany/Deutschland 01-40-96-52-21 9 5407 580 Finland/Suomi 7020-1718 Denmark/Danmark 1-505-5794-0 91 324 40 00 Inside Spain +34 91 324 40 00 Outside Spain Spain/España +47 2232 4375 Norway/Norge 5-520-1835 1-800-347-0178 Inside US +1-954-255-2610 Outside US Latin America Sales Support 84452900 Sweden/Sverige AP 300 Access Port Quick Installation Guide 802.11a/b/g Access Port External Antenna Model WSAP-5100-100-WW +65-6796-9600 Mexico/México 2-484441 Italy/Italia France 11-8095311 2.4 to 2.5 ISM range The lock port, compatible with Kensington-style security cables, is on the side of the case. 315-271700 4.9 to 5.875 range Transmit and receive • Supports a single antenna or dual antennas in diversity mode • Reverse BNC connectors for 2.4-2.5Ghz and Reverse SMA connectors for 4.9-5.825Ghz (Primary Antenna connectors marked • and Secondary Antenna connectors marked ••) • One RJ-45 connector • Two redundant sets of LED indicators, top and bottom; slots next to the bottom LEDs are for a clip on the light pipe • Point for a safety wire loop • Kensington-compatible lock port • Slots for wall mounting Lock Port Features Netherlands/Nederland Transmit and receive 1, 2, 5.5, 11 CCK 6, 9, 12, 18, 24, 36, 48, 54 ODFM GHz South Africa The AP 300 Access Port is an IEEE 802.11-compliant device containing one 802.11a radio and one 802.11b/g radio. The unit supports external antennas, listed under Supported Antennas, and it requires power from any UL-listed, 802.3af-compatible Power Over Ethernet (PoE) switch or power injector. Description 6, 9, 12, 18, 24, 36, 48, 54 802.11b/g Utilizing Diversity Contact local distributor or call +44 118 945 7360 48VDC typical; 36-57VDC range 100mA to 165mA 250mA -20°C to 50°C (-4°F to 122°F) 5% to 95% non-condensing 2438m (8,000ft.) -40°C to 70°C (-40°F to 158°F) 85% 4572m (15,000ft.) 91cm (36in.) to concrete +/-15kV air; +/-8kV contact; +/-2kV pin UL 2043 • AP 300 Access Port with external antenna connectors (Plenum Rated) • Two wall mount screws • Two wall anchors • Light pipe • Badge for light pipe • Decal for badge • Quick Installation Guide AP 300 Access Port Package Contents 802.11a Mbps Data Rate Support Europe/Mid-East Distributor Operations (3) Task Booting Radio Characteristics Length Width Height Weight The LEDs provide a status display indicating error conditions, transmission, and network activity for the 802.11a (amber) radio or the 802.11b/g (green) radio. Dimensions & Weight Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan); No part of this publication can be modified or adapted in any way, for any purposes without permission in writing from Symbol Technologies (Symbol). The material in this manual is subject to change without notice. Symbol reserves the right to make changes to any product to improve reliability, function, or design. European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713rev. 07/04 (A) Warranty Symbol Technologies (hereafter “Seller”) hardware Products are warranted against defects in workmanship and materials for a period of twelve (12) months from the date of shipment, unless otherwise provided by Seller in writing, provided the Product remains unmodified and is operated under normal and proper conditions. Warranty provisions and durations on software, integrated installed systems, Product modified or designed to meet specific customer specifications (“Custom Products”), remanufactured products, and reconditioned or upgraded products, shall be as provided in the applicable Product specification in effect at the time of purchase or in the accompanying software license. (B) Spare Parts Spare parts (i.e. parts, components, or subassemblies sold by Seller for use in the service and maintenance of Products) are warranted against defects in workmanship and materials for a period of thirty (30) days from the date of shipment. Spare parts may be new or originate from returned units under the conditions set forth in subsection D below. (C) Repair of Symbol-branded hardware For repairs on Symbol-branded hardware Products under this Agreement, including repairs covered by warranty, the repair services provided are warranted against defects in workmanship and materials on the repaired component of the Product for a period of thirty (30) days from the shipment date of the repaired Product, or until the end of the original warranty period, whichever is longer. (D) Product Service Products may be serviced or manufactured with parts, components, or subassemblies that originate from returned products and that have been tested as meeting applicable specifications for equivalent new material and Products. The sole obligation of Seller for defective hardware Products is limited to repair or replacement (at Seller’s option) on a “return to service depot” basis with prior Seller authorization. Customer is responsible for shipment to the Seller and assumes all costs and risks associated with this transportation; return shipment to the Customer will be at Seller's expense. Customer shall be responsible for return shipment charges for product returned where Seller determines there is no defect (“No Defect Found”), or for product returned that Seller determines is not eligible for warranty repair. No charge will be made to Buyer for replacement parts for warranty repairs. Seller is not responsible for any damage to or loss of any software programs, data or removable data storage media, or the restoration or reinstallation of any software programs or data other than the software, if any, installed by Seller during manufacture of the Product. (E) Original Warranty Period Except for the warranty applying solely to the repaired component arising from a repair service as provided in Section C above, the aforementioned provisions do not extend the original warranty period of any Product that had either been repaired or replaced by Seller. (F) Warranty Provisions The above warranty provisions shall not apply to any Product (i) which has been repaired, tampered with, altered or modified, except by Seller’s authorized service personnel; (ii) in which the defects or damage to the Product result from normal wear and tear, misuse, negligence, improper storage, water or other liquids, battery leakage, use of parts or accessories not approved or supplied by Symbol, or failure to perform operator handling and scheduled maintenance instructions supplied by Seller; (iii) which has been subjected to unusual physical or electrical stress, abuse, or accident, or forces or exposure beyond normal use within the specified operational and environmental parameters set forth in the applicable Product specification; nor shall the above warranty provisions apply to any expendable or consumable items, such as batteries, supplied with the Product. EXCEPT FOR THE WARRANTY OF TITLE AND THE EXPRESS WARRANTIES STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES ON PRODUCTS FURNISHED HEREUNDER INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD. SOME STATES OR COUNTRIES DO NOT ALLOW A LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS. IN SUCH STATES OR COUNTRIES, FOR SUCH PRODUCTS, SOME EXCLUSIONS OR LIMITATIONS OF THIS LIMITED WARRANTY MAY NOT APPLY. The stated express warranties are in lieu of all obligations or liabilities on the part of Seller for damages, including but not limited to, special, indirect or consequential damages arising out of or in connection with the use or performance of the Product or service. Seller’s liability for damages to Buyer or others resulting from the use of any Product or service furnished hereunder shall in no way exceed the purchase price of said Product or the fair market value of said service, except in instances of injury to persons or property. D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581; D414,171; D414,172; D418,500; D419,548; D423,468; D424,035; D430,158; D430,159; D431,562; D436,104; 5,912,662; 6,011873; 6,080,001; 6,234,389; 6,193,152B1; Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any Symbol Technologies, Inc., intellectual property rights. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license exists only for equipment, circuits, and subsystems contained in Symbol products. Symbol and the Symbol logo are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc. One Symbol Plaza Holtsville, N.Y. 11742-1300 http://www.symbol.com Patents This product is covered by one or more of the following U.S. and foreign Patents: For the latest version of this guide go to: http://www.symbol.com/manuals Warranty (2) (1) 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,760,248; 4,806,742; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,557,093; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,627,359; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,848,064; 5,850,078; 5,861,615; 5,874,720; 5,875,415; 5,900,617; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,059; 5,923,025; 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,947; 6,029,894: 6,031,830; 6,036,098; 6,047,892; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,082,621; 6,084,528; 6,088,482; 6,092,725; 6,101,483; 6,102,293; 6,104,620; 6,114,712; 6,115,678; 6,119,944; 6,123,265; 6,131,814; 6,138,180; 6,142,379; 6,172,478; 6,176,428; 6,178,426; 6,186,400; 6,188,681; 6,209,788; 6,209,789; 6,216,951; 6,220,514; 6,243,447; 6,244,513; 6,247,647; 6,308,061; 6,250,551; 6,295,031; 6,308,061; 6,308,892; 6,321,990; 6,328,213; 6,330,244; 6,336,587; 6,340,114; 6,340,115; 6,340,119; 6,348,773; D305,885; 72-69571-01 Revision 2 September 2004 Operating Voltage Operating Current Peak Current Operating Temperature Operating Humidity Operating Altitude (max ) Storage Temperature Storage Humidity Storage Altitude (max.) Drop (without antennas) Electrostatic Discharge Plenum Rated Technical Specifications The AP 300 Access Port receives all power and transfers data through the same CAT-5 cable. There is no additional power supply required. The AP 300 Access Port, a component of the Symbol Wireless Switch System, links wireless 802.11a/b/g devices to the switch, enabling growth of your wireless network with a costeffective alternative to standard access points. The AP 300 Access Port provides two placement options: wall and ceiling. Wall mount slots fit onto two screws provided. Arrows on the case guide placement of the screws. For placement above a suspended ceiling, a safety wire tie point on the case provides for a loop of regulatory safety wire, and the light pipe, a pair of small pipes, fits through a hole in the ceiling tile to provide a view of the unit’s status lights. Device Introduction Radio Transmitters (Part 15) Installation Instructions Suspended Ceiling Tile (Plenum) Mount Supported Antennas The AP 300 Access Port mounts either on a wall with mounting screws or in the ceiling. Ceiling mount requires placing the AP 300 Access Port above a suspended ceiling and installing the provided light pipe for viewing the status lights of the unit. Contact a Symbol sales associate for these and other available AP 300 Access Port antenna options. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 802.11b/g Antennas Radio Frequency Interference Requirements – Canada To prepare for installation, perform the following steps: 1. Match the model number on the purchase order with the model numbers in the packing list and on the case of the device shipped. 2. Verify that the contents of the box include the intended AP 300 Access Port and mounting hardware: Item Notes WSAP-5100-100-WW 802.11a and 802.11b/g configurations with external RSMA (.11a radio) and RBNC (.11g radio) antenna connectors. The antenna is a separate purchasable item. Mounting Hardware: Two Phillips pan head self-tapping screws. 3. Review site survey and network analysis reports to determine the location and mounting position for the AP 300 Access Port. 4. Connect a CAT-5 cable to a compatible 802.3af power source and run the cable to the installation site. Ensure that there is sufficient slack on the cable to perform the installation steps. Note: Notes or warnings about suspended ceiling mounts apply to all installations where the unit is placed on suspended ceiling tile. The case has a safety wire tie point for a standard safety wire. Caution: Symbol does not recommend mounting the AP 300 Access Port directly to any suspended ceiling tile with a thickness less than 1.27cm (0.5in.) or a suspended ceiling tile with an unsupported span greater than 66cm (26in.). Symbol does strongly recommend fitting the AP 300 Access Port with a safety wire suitable for the specific installation. The safety wire should be a standard ceiling suspension cable or equivalent steel wire between .159cm (.062in.) and .25cm (.10in.) in diameter. This placement requires installation of the provided light pipe for viewing the status lights of the unit. This Class B digital apparatus complies with Canadian ICES-003. Antenna Option 2.4-2.5Ghz, 11.2dBi 120 Degree Sector Antenna 2.4-2.5Ghz, 2dBi Fixed Point Dipole Antenna 2.4-2.5Ghz, 4.6dBi OMNI Antenna 2.4-2.5Ghz, 14.2dBi YAGI Antenna Part Number ML-2499-11PNA2-01 ML-2499-APA2-01 ML-2499-HPA3-01 ML-2499-BYGA2-01 802.11a Antennas Antenna Option 4.9GHz to 5.825GHz, 2dBi RSMA Dipole Antenna 4.9GHz to 5.825GHz, 14.2dBi Patch Antenna 4.9GHz to 5.825GHz, 5.9dBi OMNI Antenna Wall Mount Part Number ML-5299-APA1-01 ML-5299-WPNA1-01 ML-5299-HPA1-01 Regulatory Information Wall mounting requires hanging the AP 300 Access Port along its width or length using the pair of slots on the bottom of the unit. The AP 300 can be mounted onto any plaster, wood, or cement wall surface using the provided wall anchors when necessary. The illustration shows a lengthwise mount. All Symbol devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to Symbol Technologies equipment, not expressly approved by Symbol Technologies, could void the user’s authority to operate the equipment. Use only the approved antennas. Unauthorized antennas, modifications, or attachments could cause damage and may violate regulations. This device is to be used only with Symbol Technologies Wireless Switch. Country Approvals Regulatory markings are applied to the device signifying the radio (s) are approved for use in the following countries: United States, Canada, Australia, Japan & Europe 1,2. Please refer to the Symbol Declaration of Conformity (DoC) for details of other country markings. This is available at http://www2.symbol.com/doc/. Note 1: For 2.4GHz Products: Europe includes, Austria, Belgium, Croatia, Czech Republic, Croatia, Cyprus, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovak Republic, Slovenia, Spain, Sweden, Switzerland, and the United Kingdom. (7) Wall Mount Hardware • Two Phillips pan head self-tapping screws • Two wall anchors • Safety wire (recommended) and security cable (optional) Note: In the event that the original mounting screws are lost, the following screws can be used instead:(ANSI Standard) #6-18 X 0.875in. Type A or AB Self-Tapping Screw, or (ANSI Standard Metric) M3.5 X 0.6 X 20mm Type D Self-Tapping Screw (9) Ceiling Mount Hardware • Light pipe • Badge for light pipe • Decal for badge • Safety wire (recommended) and security cable (optional) Ceiling Mount Procedure 1. If possible, remove the ceiling tile from its frame and place it, finished side down, on a work surface. 2. If required, install a safety wire, between .15cm (.06in.) and .25cm (.10in.) in diameter, in the ceiling space. Wall Mount Procedure 1. Orient the case on the wall by its width or length. 3. If required, install and attach a security cable to the unit’s lock port. 2. Using the arrows on one edge of the case as guides, 4. Mark a point on the upper or unfinished side of the tile. 5. Push the light pipe through the tile at the mark and remove the light pipe. If necessary, use a drill to make a hole in the tile. 6. Snap the clips of the light pipe into the bottom of the case. 7. Fit the light pipe into hole in the tile from its unfinished side. 8. Place the decal on the back of the badge and snap the badge onto the light pipe from the finished side of the tile. 9. Attach appropriate antennas to the connectors. Alignment Arrows move the edge to the midline of the mounting area and mark points on the midline for the screws. 3. At each point, drill a hole in the wall, insert an anchor, screw into the anchor the wall mounting screw and stop when there is 1mm between the screw head and the wall. Note: When pre-drilling a hole the recommended hole size is 2.8mm (0.11in.) if the screws are going directly into the wall and 6mm (0.23in.) if the provided wall anchors are being used. 4. If required, loop a safety wire, between .15cm (.06in.) and .25cm (.10in.) in diameter, around the tie post and secure the loop. 5. If required, install and attach a security cable to the unit’s lock port. 6. Place the large corner of each of the case’s mount slots over the screw heads. 7. Slide the case down along the mounting surface to hang the mount slots on the screw heads. 8. Attach appropriate antennas to the connectors. 9. Attach the Ethernet cable to the unit and to a switch with an 802.3af compatible power source. 10. Attach any safety wire to the safety wire tie point or security cable to the unit’s lock port. 11. Bring the tile into the ceiling space. 12. Plug the Ethernet cable into the the unit and to a switch with an 802.3af-compatible power source. 13. Verify the unit has power by observing the LEDs. 14. Place the ceiling tile back in its frame. 10. Verify the unit has power by observing that the LEDs are lit or flashing. (8) (10) Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Radio Transmitters This device complies with RSS 210 of Industry & Science Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Label Marking: The Term “IC:” before the radio certification only signifies that Industry Canada technical specifications were met. CE Marking and European Economic Area (EEA) The use of 2.4GHz RLAN’s, for use through the EEA, have the following restrictions: • Maximum radiated transmit power of 100 mW EIRP in the frequency range 2.400 -2.4835 GHz • France, outside usage is restricted to 2.4-2.454 GHz • Belgium, outside usage is restricted to 2.460-2.4835 GHz • Italy requires a user license for outside usage. The use of 5GHz RLAN’s has varying restrictions for use within the EEA; please refer to the Symbol Declaration of Conformity (DoC) for details at http://www2.symbol.com/doc/ Statement of Compliance Symbol Technologies, Inc., hereby, declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A Declaration of Conformity may be obtained from http://www2.symbol.com/doc/ Other Countries Mexico - Restrict Frequency Range to: 2.450 - 2.4835 GHz. Sri Lanka - Restrict Frequency Range to: 2.400 – 2.430 GHz. (11) Note 2: The use of 5GHz RLAN’s has varying restrictions of use; please refer to the Symbol Declaration of Conformity (DoC) for details. Operation of the device without regulatory approval is illegal. Frequency of Operation The use on UNII (Unlicensed National Information Infrastructure) Band 1 5150-5250 MHz is restricted to indoor use only. FCC/EU RF Exposure Guidelines Safety Information The device complies with Internationally recognised standards covering Specific Absorption Rate (SAR) related to human exposure to electromagnetic fields from radio devices. It is advisable to use the device only in the normal operating position. Remote and Standalone Antenna Configurations To comply with FCC RF exposure requirements, antennas that are mounted externally at remote locations or operating near users at stand-alone desktop or similar configurations must operate with a minimum separation distance of 20 cm from all persons. Power Supply This device is powered from a 802.3af compliant power source which is UL approved. Radio Frequency Interference Requirements This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help. (12) (13) Customer Support Symbol Technologies provides its customers with prompt and accurate customer support. Use the Symbol Support Center as the primary contact for any technical problem, question or support issue involving Symbol products. If the Symbol Customer Support specialists cannot solve a problem, access to all technical disciplines within Symbol becomes available for further assistance and support. Symbol Customer Support responds to calls by e-mail, telephone or fax within the time limits set forth individual contractual agreements. When contacting Symbol Customer Support, please provide the following information: • Device serial number • Product name or model number • Software type and version number North American Contacts Inside North America, contact Symbol at: Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 1-631-738-2400/1-800-SCAN 234 Fax: 1-631-738-5990 International Contacts Outside North America, contact Symbol at: Symbol Technologies, Inc. Symbol Place Winnersh Triangle, Berkshire, RG41 5TP United Kingdom 0800-328-2424 (Inside UK) /+44 118 945 7529 (Outside UK) For warranty and service information, contact the Symbol Support Center: telephone 1-631738-6213 or 1-800-653-5350; fax: (631) 563-5410; or E-mail: support@symbol.com. Web Support Sites and Additional Information MySymbolCare Symbol Services Homepage Symbol Software Updates Symbol Developer Program Symbol Knowledge Base http://www.symbol.com/services/msc/ http://symbol.com/services/ http://symbol.com/services/downloads/ http://software.symbol.com/devzone/ http://kb.symbol.com/register.asp Obtain additional information by contacting Symbol at: • 1-800-722-6234, inside North America • +1-631-738-5200, in/outside North America • http://www.symbol.com/ (14)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:a3ef2168-3136-4ea1-8d05-108fe3323c67 Producer : Acrobat Distiller 6.0.1 (Windows) Create Date : 2004:09:17 12:43:45-07:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2004:09:17 12:43:45-07:00 Document ID : uuid:904af0e1-c212-44d7-8fff-e23259133f86 Format : application/pdf Title : AP300QIGver13_11x17.fm Creator : mstocksiek Author : mstocksiekEXIF Metadata provided by EXIF.tools