TAIYO YUDEN EYSMJCS Complete Class 2 Bluetooth Module User Manual
Taiyo Yuden Co., Ltd. Complete Class 2 Bluetooth Module
user manual
24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Bluetooth® Module EYSMJCS (RF+Baseband (Class 2) USB) User’s Manual In case you adopt this module and design some appliance, please ask for the latest specifications from the local sales office. We wish the customer to request the Specification Report when the design for the mass production begins because the content of this Data Report might change without a previous notice to the customer. The Bluetooth® word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by TAIYO YUDEN CO., LTD. is under license. 1/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Document constituent list Control name General Items Absolute maximum ratings Electrical characteristics Electrical characteristics Electrical characteristics Electrical characteristics Circuit schematic Outline / Appearance Outline / Appearance Pin Layout Control No. HD-AG-A071063 HD-AM-A071063 HD-AE-A071063 HD-AE-B071063 HD-AE-C071063 HD-AE-D071063 HD-MC-A071063 HD-AD-A071063 HD-AD-B071063 HD-BA-A071063 Document Page 1/3 – 3/3 1/1 1/3- 3/3 1/2 - 2/2 1/13 - 13/13 1/10- 10/10 1/1 1/1 1/1 1/1 Rev. record 24-Aug.-2007> Ver.0.1 2/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. Control name HD-AG-A071063 (1/3) General Items Scope This specification (“Specification”) applies to the hybrid IC “EYSMJCS” for use Bluetooth® module (“Product”) manufacture by TAIYO YUDEN Co., Ltd. (“TAIYO YUDEN”) 1. User’s Code: EYSMJCS (USB I/F Support) Type: EYSMJCS 2. Function: Radio frequency transfer Module (power class 2). Bluetooth® standard Ver 2.0+EDR conformity 3. Application: Laptop PC 4. Structure: Hybrid IC loaded with silicon monolithic semiconductor 5. Outline: FFC/FPC Connector Type 6. Marking: TBD 7. Features: -Bluetooth® 2.0+EDR conformity -USB Interface -Point-to-Multipoint (7 Slaves) -Encryption -Hold, Sniff and Park Mode -Supported Link Type: ACL -AFH -EDR (Enhanced Data Rate) 8. Packing: TBD 9. Terminal: Data input-output (6pin Cable Connector) RF input-output (Antenna) 10. Mount: TBD 11. Notes: a. Any question arising from this Specification shall be solved through mutual discussion by the parties hereof. b. This Product is not designed for radiation durable and should not be used under the circumstance of radiation. 3/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AG-A071063 Ver.0.1 (2/3) Control name General Items c. The operating conditions of this Product are as shown in this Specification. Please note that TAIYO YUDEN shall not be liable for a failure and/or abnormality which is caused by use under the conditions other than the operating conditions hereof. d. This Product mentioned in this Specification is manufactured for use in Laptop PC. Before using this Product in any special equipment (such as medical equipment, space equipment, air craft, disaster prevention equipment), where higher safety and reliability are duly required, the applicability and suitability of this Product must be fully evaluated by the customer at its sole risk to ensure correct and safety operation of those special equipments. Also, evaluation of the safety function of this Product even for use in general electronics equipment shall be thoroughly made and when necessary, a protective circuit shall be added in design stage, all at the customer’s sole risk. e. TAIYO YUDEN warrants only that this Product is in conformity with this Specification for one year after purchase and shall in no event give any other warranty. f. The warranty period shall be one year. g. Communication between this Product and others might not be established nor maintained depending upon radio environment or operating conditions of this Product and other Bluetooth® products. h. This Product is designed for use in products which comply with Bluetooth® Specifications (Ver 2.0+EDR) (“Bluetooth Specifications”). TAIYO YUDEN disclaims and is not responsible for any liability concerning infringement by this Product under any intellectual property right owned by third party in case the customer uses this Product in any product which does not comply with Bluetooth Specifications (the “non-complying products”). Furthermore, TAIYO YUDEN warrants only that this Product complies with this Specification and does not grant any other warranty including warranty for application of the non-complying products. i. TAIYO YUDEN dose not render updating or upgrading service for the firmware in the Module. j. In order to take tests for getting the certification of each country’s Radio Law with a device incorporating this module, it is necessary to make the software in Host to put the module into test condition. Please contact TAIYO YUDEN for farther details. k. Please evaluate adequately our module incorporated to your products before mass production. l. This Product operates in the unlicensed ISM band at 2.4GHz. In case this Product is used around the other wireless devices which operate in same frequency band of this Product, there is a possibility that interference occurs between this Product and such other devices. If such interference occurs, please stop the operation of other devices or relocate this Product before using this Product or do not use this Product around the other wireless devices. 4/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AG-A071063 Ver.0.1 (3/3) Control name General Items m. Containment of hazardous substance in this Product *Pb (Lead) : Non use *Additional RoHS regulation substance (Cd.Hg.Cr+6.PBB.PBDE) :Non use n. In addition when this Product is used under environmental conditions such as over voltage which are not guaranteed ,it may be destroyed in short mode. To ensure the security of customer’s product, please add an extra fuse or/and a protection circuit for over voltage. p. In some cases, TAIYO YUDEN may use replacements as component parts of Products. Such replacement shall apply only to component part of Products, which TAIYO YUDEN deems it possible to replace or substitute according to (i) Scope provided in this Specification (e.g. Official Standard (Type Approvals, Bluetooth LOGO etc.)) and (ii) Quality of Products. TAIYO YUDEN also ensures traceability of such replacement on production lot basis. r. Do not alter Hardware and/or Software of this Product. Please note that TAIYO YUDEN shall not be liable for any problem if it is caused by customer's alteration of Hardware or/and Software without Taiyo Yuden's prior approvals. This module is still under development, thus specifications do not guarantee both the quality and reliability at the time of shipment. Since the specifications and mass production of the module are not confirmed either, the contents of the technical notes are subject to change without any prior notice. 5/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AM-A 071063 Control name Absolute maximum ratings (1/1) Absolute maximum ratings Item Supply voltage Input voltage Symbol Min. Typ. Rating Max. Remark Unit VDD -0.3 3.6 Vin -0.3 VDD+0.3 Ta=25 degrees C, GND reference I/O terminals except USB interface Recommendation operating range Item Symbol Supply voltage Supply voltage ripple and spike noise Operation temperature range Storage temperature range VDD Min. 3.15 Rating Typ. Max. 3.3 3.45 VDD_rn Unit (30) mVp-p Topr 25 70 Degrees C Tstg -30 25 85 Degrees C Remark Note 1 Humidity=40%RH Note 2 Humidity=40%RH Note 3 Notes: 1. To fill the standard of “Supply voltage ripple and spike noise”, the capacitor, which has the capacity of 2.2uF or more, should be put in the terminal VDD outside as a bypass capacitor . 2. Operating temperature range is set to satisfy products electrical characteristics in the short term. In terms of product life cycle when it is used in condition of varying from TYP standard in the long term, please refer to the reliability condition. 3. Storage temperature range is the condition for transportation and storage in temporary. 6/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-A071063 Electrical characteristic (1/3) Control name Electrical characteristics DC Specifications The Specification applies for Topr.= 25 degrees C, VDD=3.3V No. Parameter Condition Normal supply voltage Input Low Voltage 1 Input Low Voltage 2 Input High Voltage 1 Input High Voltage 2 Output Low Voltage 1 Output Low Voltage 2 Output High voltage 1 Output High voltage 2 /RESET, PIOX USB_D+, USB_D/RESET, PIOX USB_D+, USB_DPIOX USB_D+, USB_DPIOX USB_D+, USB_D- Symbol VDD VIL1 VIL2 VIH1 VIH2 VOL1 VOL2 VOH1 VOH2 Min. 3.15 -0.3 0.7xVDD 2.0 VDD-0.4 2.8 Typ. 3.3 Max. 3.45 0.8 0.8 VDD+0.3 0.4 0.3 Unit Remark V IOL=4mA V IOH=-4mA mA Notes 3, 4 10 Peak current Continuous Rx Iccp1 (42) (120) 11 Average current1 12 Average current2 Sniff mode (Slave only) Standby mode Icca1 Icca2 (10) (9) 13 Average current3 Send DM1packet (Master) Icca3 (36) mA Notes 1, 3, 4 mA Notes 3, 4 mA Notes 3, 4 14 Average current4 15 Average current5 16 Average current6 Receive DM1packet (Slave) Hold mode (Slave only) Park mode (Slave only) Icca4 Icca5 Icca6 (37) (9) (9) mA Notes 3, 4 mA Notes 3, 4 mA Notes 2, 3, 4 Notes: 1. Sniff mode parameter. Max interval 0050h Min interval 0010h Attempt 0005h Timeout 0005h 2. Park mode parameter. Max interval 0100h Min interval 0010h 3. The consumption current might fluctuate with the condition of radio communication, host performance and test circuit. 4. The value may fluctuate several (mA) depending on Firmware version. 7/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. Control name HD-AE-A071063 (2/3) Electrical characteristics AC Specifications The Specification applies for Topr.= 25 degrees C, VDD=3.3V No. Parameter Condition Symbol Min Typ Max Unit ms Note 1 ms Note 2 ms Notes 3, 4 VDD Rise Time from 0V to 3.15V t1 VDD= 3.15V to /RESET High t2 10 /RESET High to Module Ready t3 /RESET Pulse Width t4 DETACH High to USB I/F High-Z t5 DETACH Low to USB I/F Active t6 /RESET High to /RESET Low t7 3000 /RESET Low to USB_I/F High-Z t8 Module Active to /RESET Low t9 ms 10 /RESET Low to VDD_3.3V Off t10 ms (100) 3000 Remark ms 130 ms 10 ms ms 10 Note 5 ms Note 5 Notes: 1. This module has an internal flash memory and a function to erase/sort unnecessary data if certain HCI commands are issued and consume more than a certain level of free space in the flash memory. This operation occurs at every module initialization (power-on). If supply voltage becomes non-defined states during initialization or writing in flash memory, data in flash memory might be destroyed. If the data in flash memory is destroyed, module will not work correctly. Therefore please be sure to stabilize power source before /RESET release. In addition please design module peripheral circuits to avoid temporary blackout of power source during operation. Please refer HD-AE-C 071063 for HCI command which rewrites flash memory data. 2. Input /RESET signal of 10ms and more in condition of VDD_3.3V at over 3.15V. 3. When the module is ready to accept the command, its module outputs the “0F 04 00 01 00 00” (Hex) USB to the Data Line. After that, please access to the module. 4. The Typ. is a reference value. The value may change depending on the firmware version and conditions of use. 5. You don’t need to wait t6 if you confirm that this module has output “0F 04 00 01 00 00” (Hex). 8/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-A071063 Control name Electrical characteristics (3/3) VDD t2 t7 t1 /RESET (Note 1) t4 USB_DETACH t3 t9 t8 t5 Active USB_I/F Active t6 Active Timing Diagram for Power Up Sequence VDD_3.3V t10 /RESET (Note 1) USB_DETACH USB_I/F Active Timing Diagram for Power Down Sequence 9/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-B071063 (1/2) Control name Electrical characteristics RF Specifications at Basic Rate The Specification applies for Ta=25 degrees C, VDD=3.3V No. Parameter Condition Symbol Min Typ Max Unit FREQ PO 2400 -6 2483.5 MHz +4 dBm dF1: F0(11110000) M1 140 dF2: AA(10101010) M4 115 dF2/dF1 MC 0.8 2MHz(|M-N|=2) ISE1 -20 dBm 3MHz or greater (|M-N|>=3) ISE2 -40 dBm Remark 10 11 12 13 14 15 Frequency band Tx power Modulation characteristics 1 Modulation characteristics 2 Modulation characteristics 3 In-band spurious emission 2 spurious In-band emission 3 Initial Carrier Frequency Frequency Drift 1 Frequency Drift 2 Drift rate C/I co-channel C/I 1MHz C/I 2MHz C/I >= 3MHz 16 C/I Image CI4 -9 dB 17 C/I Image +/- 1MHz Out-of-Band Blocking 1 Out-of-Band Blocking 2 Out-of-Band Blocking 3 CI5 -20 dB OBB1 -10 dBm OBB2 -27 dBm OBB3 -27 dBm OBB4 -10 dBm BER<=0.1 dBm BER<=0.1 18 19 20 21 Out-of-Band Blocking 4 23 Maximum Input Level 20dB Bandwidth 24 Sensitivity-single 25 Sensitivity-multi 22 DH1 DH3,DH5 DH1,DH3,DH5 30MHz to 2000MHz f=2460MHz 2000 to 2399MHz f=2460MHz 2484 to 3000MHz f=2460MHz 3000MHz to 12.75GHz f=2460MHz 175 kHz kHz ICF -75 +75 kHz FD1 FD2 DR CIC CI1 CI2 CI3 -25 -40 +25 +40 400 11 -30 -40 kHz kHz Hz/us dB dB dB dB MAXP -20 B20 MHz DH1 SEN1 -70 dBm DH3,DH5 SEN2 -70 dBm -60dBm -60dBm -60dBm -67dBm -3MHz offset -67dBm -67dBm BER<=0.1 BER<=0.1 BER<=0.1 BER<=0.1 BER<=0.1 10/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-B071063 (2/2) Control name Electrical characteristics RF Specifications at EDR The Specification applies for Ta=25 degrees C, VDD =3.3V No. Parameter Condition Symbol Min Typ Max Unit Pai/4DQPSK 8DPSK Pai/4DQPSK 8DPSK Pai/4DQPSK 8DPSK RDE1 RDE2 PDE1 PDE2 D991 D992 |M-N|=1 EISE1 |M-N|=2 EISE2 -20 dBm |M-N|=3 EISE3 -40 dBm -75 +75 kHz -10 PGFSK -4 +10 PGFSK +1 kHz 15 16 17 18 RMS DEVM 1 RMS DEVM 2 Peak DEVM 1 Peak DEVM 2 99% DEVM 1 99% DEVM 2 EDR In-band spurious emission 1 EDR In-band spurious emission 2 EDR In-band spurious emission 3 EDR Initial Carrier Frequency EDR Drift Relative transmit power Actual Sensitivity Level BER Floor Performance C/I co-channel C/I 1MHz C/I 2MHz C/I >= 3MHz 19 C/I Image 20 21 22 23 24 10 11 12 EICF ED PDPSK RTP 2-DH5(3-DH5) 16000000bit 2-DH5(3-DH5) 160000000bit 2-DH5 2-DH5 2-DH5 2-DH5 Remark 0.20 0.13 0.35 0.25 0.30 0.20 26 dB dB ESEN -70 dBm BER= 10-4 FSEN -60 dBm BER= 10-5 2CIC 2CI1 2CI2 2CI3 13 -30 -40 dB dB dB dB 2-DH5 2CI4 -7 dB C/I Image +/- 1MHz C/I co-channel C/I 1MHz C/I 2MHz C/I >= 3MHz 2-DH5 3-DH5 3-DH5 3-DH5 3-DH5 2CI5 3CIC 3CI1 3CI2 3CI3 -20 21 -25 -33 dB dB dB dB dB 25 C/I Image 3-DH5 3CI4 dB 26 C/I Image +/- 1MHz 3-DH5 -13 dB 27 Maximum Input Level 2-DH5(3-DH5) 3CI5 EMAX 13 14 -20 -60dBm -60dBm -60dBm -67dBm -67dBm -3MHz offset -67dBm -60dBm -60dBm -60dBm -67dBm -67dBm -3MHz offset -67dBm dBm Note: Bluetooth® standard Ver 2.0+EDR conformity 11/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. Control name HD-AE-C071063 (1/13) Electrical characteristics Supported HCI Commands / HCI Events The Bluetooth® functions of this module is as written in the attached PICS. Depending on firmware version Upgrade, the Bluetooth® functions are subject to change without notice. HCI COMMAND LIST Firmware Version 21e (Build3164) OpCode Group (Hex) Command (Hex) Parameters HCI _Inquiry 0x0401 LAP Inquiry Length Num Responses HCI _ Inquiry_ Cancel 0x0402 Command Description Returns Status Notes LINK CONTROL Inquiry HCI_ Periodic_ Inquiry _Mode 0x0403 HCI _Exit _Periodic _Inquiry _Mode 0x0404 Max Period Length Min Period Length LAP Inquiry Length Num Responses Yes Status Yes Status Yes Status Yes Connection Management HCI _Create_ Connection 0x0405 HCI _Disconnect 0x0406 HCI _Add _SCO _Connection 0x0407 HCI _Create _Connection _Cancel 0x0408 HCI _Accept _Connection _Request 0x0409 HCI _Reject _Connection _Request HCI _Change _Connection _Packet _Type 0x040A 0x040F HCI _Setup _Synchronous _Connection 0x0428 28 HCI _Accept _Synchronous _Connection _Request 0x0429 29 HCI _Reject _Synchronous _Connection _Request 0x042A 2A BD ADDR Packet Type Page Scan Repetition Mode Page Scan Mode Clock Offset Allow Role Switch Connection Handle Reason SCO Handle Packet Type BD ADDR BD ADDR Role BD ADDR Connection Handle Packet Type Connection_Handle Transmit_Bandwidth Receive_Bandwidth Max_Latency Voice_Setting Retransmission_Effort Packet_Type BD ADDR Transmit_Bandwidth Receive_Bandwidth Max_Latency Content Format Retransmission_Effort Packet_Type BD ADDR Reason Status BD_ADDR Yes a,b Yes Yes b,c, d,j,p Yes Yes Yes Yes Yes l,m, o,p Yes l,m,o Yes l,m,o 12/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 Control name Electrical characteristics (2/13) Authentication / Pairing HCI _Link _Key _Request _Reply 0x040B BD ADDR Link Key HCI _Link _Key _Request _Negative _Reply 0x040C BD ADDR HCI _PIN _Code _Request _Reply 0x040D BD ADDR PIN Code Length PIN Code 0x040E BD ADDR HCI _PIN _Code _Request _Negative _Reply HCI _Authentication _Requested HCI _Change _Connection _Link _Key Status BD ADDR Status BD ADDR Status BD ADDR Yes Status BD ADDR Yes Yes Yes 0x0411 11 Connection Handle Yes 0x0415 15 Connection Handle Yes HCI _Set _Connection _Encryption 0x0413 13 HCI _Master _Link _Key 0x0417 17 Encryption Connection Handle Encryption Enable Key Flag Yes Yes Remote Information HCI _Remote _Name_ Request HCI _Remote _Name _Request _Cancel HCI _Read _Remote _Supported _Features HCI _Read _Remote _Extended _Features HCI _Read _Remote _Version _Information HCI _Read _Clock _Offset HCI _Read _LMP _Handle 0x0419 19 BD ADDR Page Scan Repetition Mode Page Scan Mode Clock Offset 0x041A 1A BD_ADDR 0x041B 1B Connection Handle Yes Yes Yes 0x041C 1C Connection Handle Page_Number 0x041D 1D Connection Handle 0x041F 1F Connection Handle 0x0420 20 Connection Handle Yes Status BD_ADDR Yes Yes Status Connection Handle LMP_Handle Reseved Yes 13/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 Control name Electrical characteristics (3/13) LINK POLICY Connection Handle Hold Mode Max Interval Hold Mode Min Internal Connection Handle Sniff Mode Max Interval Sniff Mode Min Interval Sniff Attempt Sniff Timeout Connection Handle Connection Handle Beacon Max Interval Beacon Min Interval Connection Handle Connection Handle Flags Service Type Token Rate Peak Bandwidth Latency Delay Variation HCI _Hold _Mode 0x0801 HCI _Sniff _Mode 0x0803 HCI _Exit _Sniff _Mode 0x0804 HCI _Park _State 0x0805 HCI _Exit _Park _State 0x0806 HIC _QoS _Setup 0x0807 HCI _Role _Discovery 0x0809 Connection Handle HCI _Switch _Role 0x080B BD ADDR Role HCI _Read _Link _Policy _Settings 0x080C Connection Handle HCI _Write _Link _Policy _Settings 0x080D Connection Handle Link Policy settings HCI _Read _Default _Link _Policy _Settings 0x080E HCI _Write _Default _Link _Policy _Settings 0x080F HCI _Flow _Specification 0x0810 10 Default Link Policy Settings Connection Handle Flags Flow direction Service Type Token Rate Token Bucket Size Peak Bandwidth Access Latency Yes Yes Yes Status Connection Handle Current Role Yes Yes Yes e,m Yes Yes States Connection Handle Link Policy Settings States Connection Handle Status Default Link Policy Settings Status Yes Yes Yes Yes No l,m 14/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 (4/13) Control name Electrical characteristics HOST CONTROLLER & BASEBAND HCI _Set _Event _Mask HCI _Reset 0x0C01 0x0C03 Event Mask HCI _Set _Event _Filter 0x0C05 Filter Type Filter Condition Type Condition HCI _Flush 0x0C08 Connection Handle HCI _Read _PIN _Type 0x0C09 HCI _Write _PIN _Type HCI _Create _New _Unit _Key 0x0C0A 0x0C0B HCI _Read _Stored _Link _Key 0x0C0D HCI _Write _Stored _Link _Key 0x0C11 11 HCI _Delete _Stored _Link _Key 0x0C12 12 HCI _Write _Local _Name 0x0C13 13 HCI _Read _Local _Name 0x0C14 14 0x0C15 15 0x0C16 16 HCI _Read _Page _Timeout 0x0C17 17 HCI _Write _Page _Timeout 0x0C18 18 HCI _Read _Scan _Enable 0x0C19 19 HCI _Write _Scan _Enable 0x0C1A 1A HCI _Read _Page _Scan _Activity 0x0C1B 1B HCI _Write _Page _Scan _Activity 0x0C1C 1C HCI _Read _Inquiry _Scan _Activity 0x0C1D 1D HCI _Write _Inquiry _Scan _Activity 0x0C1E 1E HCI _Read _Authentication _Enable 0x0C1F 1F HCI _Write _Authentication _Enable 0x0C20 20 HCI _Read _Encryption _Mode 0x0C21 21 HCI _Write _Encryption _Mode 0x0C22 22 HCI _Read _Class _of _Device 0x0C23 23 HCI _Write _Class _of _Device 0x0C24 24 HCI _Read _Voice _Setting 0x0C25 25 HCI _Write _Voice _Setting 0x0C26 26 PIN Type BD ADDR HCI _Read _Connection _Accept _Timeout HCI _Write _Connection _Accept _Timeout Read All Flag Num Keys To Write BD ADDR [I] Link Key [I] BD ADDR Delete All Flag Local Name Conn Accept Timeout Page Timeout Scan Enable Page Scan Interval Page Scan Window Inquiry Scan Interval Inquiry Scan Window Authentication Enable Encryption Mode Class of Device Voice Channel setting States States Yes Yes States Yes States Connection Handle States PIN Type States States States Max Num Keys Num Keys Read States Num Keys Written States Num Keys Deleted States States Local Name States Conn Accept Timeout States States Page Timeout States States Scan Enable States States Page Scan Interval Page Scan Window Yes Yes Yes Yes Yes Yes Yes Yes f,k Yes Yes Yes Yes Yes Yes Yes Yes States Yes States Inquiry Scan Interval Inquiry Scan Window Yes States Yes States Authentication Enable States States Encryption Mode States States Class of Device States States Voice Setting States Yes Yes Yes Yes Yes Yes Yes Yes 15/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 HCI _Read _Automatic _Flush _Timeout HCI _Write _Automatic _Flush_ Timeout HCI _Read _Num _Broadcast_ Retransmission HCI _Write _Num _Broadcast_ Retransmission (5/13) Control name Electrical characteristics 0x0C27 27 Connection Handle 0x0C28 28 Connection Handle Flash Timeout 0x0C29 29 Num Broadcast Retransmission 0x0C2A 2A HCI _Read _Hold _Mode _Activity 0x0C2B 2B HCI _Write _Hold _Mode _Activity 0x0C2C 2C HCI _Read _Transmit _Power _Level 0x0C2D 2D HCI _Read _Synchronous _Flow _Control _Enable 0x0C2E 2E 0x0C2F 2F Synchronous Flow Control Enable 0x0C31 31 Flow Control Enable HCI _Write _ Synchronous _Flow _Control _Enable HCI _Set _Controller _To _Host _Flow _Control Hold Mode Activity Connection Handle Type Host ACL Data Packet Length Host SCO Data Packet Length Host Total Num ACL Data Packets Host Total Num SCO Data Packets Number of Handles Connection handle [I] Host Num of Completed Packets [I] HCI _Host _Buffer _Size 0x0C33 33 HCI _Host _Number _Of _Completed _Packets 0x0C35 35 HCI _Read _Link _Supervision _Timeout 0x0C36 36 Connection Handle 0x0C37 37 Connection Handle Link Supervision Timeout 0x0C38 38 HCI _Read _Current _IAC _LAP 0x0C39 39 HCI _Write _Current _IAC _LAP 0x0C3A 3A 0x0C3B 3B 0x0C3C 3C 0x0C3D 3D HCI _Write _Link _Supervision _Timeout HCI _Read _Number _Of _Support _IAC HCI _Read _Page _Scan _Period _Mode HCI _Write _Page _Scan _Period _Mode HCI _Read _Page _Scan _Mode HCI _Write _Page _Scan _Mode HCI _Set _AFH _Host _Channel _Classification Ver.0.1 0x0C3E 3E 0x0C3F 3F Num Current IAC IAC LAP [I] Page Scan Period Mode Page Scan Mode AH Host Channel Classification States Connection Handle Flush Timeout States Connection Handle Yes Yes States Yes States Yes States Hold Mode Activity States States Connection Handle Power Level States Synchronous Flow Control Enable Yes Yes Yes No c,d,k States No c,d,k States Yes States Yes Yes States Connection Handle Link Supervision Timeout States Connection Handle States Num Support IAC States Num Current IAC IAC LAP [I] Yes Yes Yes Yes States Yes States Page Scan Period Mode Yes States Yes States Page Scan Mode States Status Yes Yes h,j Yes 16/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 (6/13) HCI _Read _Inquiry _Scan _Type 0x0C42 42 HCI _Write _Inquiry _Scan _Type 0x0C43 43 HCI _Read _Inquiry _Mode 0x0C44 44 HCI _Write _Inquiry _Mode 0x0C45 45 HCI _Read _Page _Scan _Type 0x0C46 46 HCI _Write _Page _Scan _Type 0x0C47 47 HCI _Read _AFH _Channel _Assessment _Mode 0x0C48 48 HCI _Write _AFH _Channel _Assessment _Mode 0x0C49 49 Control name Electrical characteristics Inquiry Scan Type Inquiry Mode Page Scan Type AFH Channel Assessment Mode Status Inquiry Scan Type Status Status Inquiry Mode Status Status Page Scan Type Status Status AFH Channel Assessment Mode Status Yes Yes Yes Yes Yes Yes Yes Yes INFORMATIONAL PARAMETERS HCI _Read _Local _Version _ Information 0x1001 0x1002 0x1003 HCI _Read _Local _Extended _Features 0x1004 HCI _Read _Buffer _Size 0x1005 HCI _Read _Country _Code 0x1007 HCI _Read _BD _ADDR 0x1009 HCI _Read _Local _Supported _Commands HCI _Read _Local _Supported _Features Page number Status HCI Version HCI Revision LMP Version Manufacturer Name LMP Subversion Status Supported Commands Status LMP_Features Status Page number Maximum Page Number Extended LMP Features Status HC ACL Data Packet Length HC Synchronous Data Packet Length HC Total Num ACL Data Packet HC Total Num Synchronous Data Packe Status Country Code Status BD ADDR Yes Yes Yes Yes Yes Yes Yes 17/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 Control name Electrical characteristics (7/13) STAUS PARAMETERS HCI _Read _Failed _Contact _Counter 0x1401 Connection Handle HCI _Reset _Failed _Contact _Counter 0x1402 Connection Handle HCI _Read _Link _Quality 0x1403 Connection Handle HCI _Read _RSSI 0x1405 Connection Handle HCI _Read _AFH _Channel _Map 0x1406 Connection Handle HCI _Read _Clock 0x1407 Which Clock Connection Handle Status Connection handle Failed Contact Counter Status Connection handle Status Connection Handle Link Quality Status Connection Handle RSSI Status Connection Handle AFH Mode AFH Channel Map Status Connection Handle AFH Mode AFH Channel Map Yes Yes Yes Yes Yes Yes TESTING HCI _Read _Loopback _Mode 0x1801 HCI _Write _Loopback _Mode HCI _Enable _Device _Under _Test _Mode 0x1802 0x1803 Loopback Mode States Loopback Mode Yes States Yes States Yes g,i 18/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 Ver.0.1 (8/13) Control name Electrical characteristics Notes: a) Up to seven connections: a slave of up to two masters, and/or a master of up to seven slave. Some operations restricted or non-functional in a scatternet. b) Chip resource limits constrain the rate at which ACL and SCO connections can be made and broken to approximately 20 per 15 seconds. The time limit can be configured. b) Up to three SCO links. Each SCO link can be routed over the chip’s PCM interface or over HCI/BCSP. Preliminary Support for SCO over USB or H4 is in place, but testing has been light. d) No HCI SCO Host Controller to Host flow control support. No HCI SCO Host to Host Controller flow control support. e) Limited support for “best effort” and “guaranteed” Qos only. f) Initial device name taken from PS Keys, and so is maintained through a reset/reboot. g) HCI Reset does not work if the device is in local loopback mode. h) Optional Paging schemes are not supported. i) Remote ACL loopback sometimes deadlocks when the device’s flow control mechanisms assert to each other. j) Bluetooth v1.1 specification command, deprecated in the v1.2 specification,or later; support retained for backwards co mpatibility. k) Bluetooth v1.1 specification command, renamed in the v1.2 specification,or later. Park Mode ---> Park State Exit Park Mode ---> Exit Park State Set Host Controller To Host Flow Control ---> Set Controller To Host Flow Control Change Local Name ---> Write Local Name Read SCO Flow Control Enable ---> Read Synchronous Flow Control Enable Write SCO Flow Control Enable ---> Write Synchronous Flow Control Enable Get Link Quality ---> Read Link Quality l) Command not in the Bluetooth v1.1 specification. m) Underlying Flow_Specification functionality the same as for QoS_Setup. n) Command which rewrites FROM in module p) CVSD not available with 3EV3 or 3EV5 EDR packets. q) HCI Setup Synchronous Connection command does not support HV1,HV2 and HV3 Packet Type. If you want to use those Packet Types, please use HCI Add SCO connection command. 19/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 Ver.0.1 Control name Electrical characteristics (9/13) HCI EVENT LIST Event Description OpCode Parameters Status Inquiry _Complete 0x01 Yes Inquiry _Result 0x02 Inquiry _Result _with _RSSI 0x22 Status Num Responses BD ADDR [I] Page Scan Repetition Mode [I] Page Scan Period Mode [I] Page Scan Mode [I] Class of Device [I] Clock Offset [I] Num Responses BD ADDR [I] Page Scan Repetition Mode [I] Page Scan Period Mode [I] Page Scan Mode [I] Class of Device [I] Clock Offset [I] RSSI [I] Notes Inquiry Yes Yes Connection Management Connection _Complete 0x03 Connection _Request 0x04 Disconnection _Complete 0x05 Synchronous _Connection _Complete 0x2C Synchronous _Connection _Changed 0x2D Status Connection Handle BD ADDR Link Type Encryption Mode BD ADDR Class of Device Link Type Status Connection Handle Reason Status Connection Handle BD ADDR Link Type Transmission Interval Retransmission Window Rx Packet Length Tx Packet Length Air Mode Status Connection Handle Transmission Interval Retransmission Window Rx Packet Length Tx Packet Length Yes Yes Yes Yes Yes 20/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 Ver.0.1 Control name Electrical characteristics (10/13) Authentication / Pairing Authentication _Complete 0x06 Return _Link _Keys 0x15 PIN _Code _Request Link _Key _Request 0x16 0x17 Link _Key _Notification 0x18 Status Connection Handle Num Keys BD ADDR [I] Link Key [I] BD ADDR BD ADDR BD ADDR Link Key Yes Yes Yes Yes Yes Encryption Encryption _Change 0x08 Change _Connection _Link _Key _Complete 0x09 Master _Link _Key _Complete 0x0A Status Connection Handle Encryption Enable Status Connection Handle Status Connection Handle Key Flag Yes Yes Yes Remote Information Remote _Name _Request _Complete 0x07 Read _Remote _Supported _Features _Complete 0x0B Read _Remote _Version _Information _Complete 0x0C Read _Remote _Extended _Features _Complete 0x23 Status BD ADDR Remote Name Status Connection Handle LMP Features Status Connection Handle LMP Version Manufacture Name LMP Subversion Status Connection Handle Page Number Maximum page number Extended LMP Features Yes Yes Yes Yes 21/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 Ver.0.1 Control name Electrical characteristics (11/13) Link Policy QoS _Setup _Complete 0x0D Role _Change 0x12 Mode _Change 0x14 Flow _Specification _Complete 0x21 Status Connection Handle Flags Service Type Token Rate Peak Bandwidth Latency Delay Variation Status BD ADDR New Role Status Connection Handle Current Mode Interval Status Connection Handle Flags Flow direction Service Type Token Rate Token Bucket Size Peak Bandwidth Access Latency Yes Yes Yes Yes b,c General Command _Complete 0x0E Command _Status 0x0F Hardware _Error 0x10 Number _Of _Completed _Packets 0x13 Data _Buffer _Overflow 0x1A Max _Slots _Change 0x1B Read _Clock _Offset _Complete 0x1C Num HCI Command Packets Command Opcode Return Parameters Status Num HCI Command Packets Command Opcode Hardware Code Number of Handles Connection Handle [I] HC Num HCI Data Packets [I] Link Type Connection Handle LMP Max Slots Status Connection Handle Clock Offset Yes Yes Yes Yes No Yes Yes Host Controller & Baseband Flush _Occurred 0x11 Connection Handle Yes Loopback _Command 0x19 Yes Connection _Packet _Type _Change 0x1D QoS _Violation 0x1E Page _Scan _Mode _Change 0x1F Page _Scan _Repetition _Mode _Change 0x20 HCI Command Packet Status Connection Handle Packet Type Connection Handle BD ADDR Page Scan Mode BD ADDR Page Scan Repetition Mode Yes No No Yes 22/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 Ver.0.1 (12/13) Control name Electrical characteristics Notes: a) Significance and expected recovery procedure is ill defined. b) Event not in the Bluetooth v1.1 specification. c) Event provoked by local Flow Specification command, even through the command is not implemented. d) Optional paging schemes not supported. Bluetooth v1.1 specification only. 23/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-C071063 Ver.0.1 (13/13) Control name Electrical characteristics Module Stack USB I/F HOST USB HCI Host Transport HCI Implementation Link Manager Link Controller Base Band Radio Note: The protocol stack in the module is compliant with the Specification of the Bluetooth® System V2.0+EDR Bluetooth® Module 24/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-D071063 (1/10) Control name Electrical characteristics PICS for Firmware Version 21d (Build3059) The Bluetooth® functions of this module are as below. Depending on firmware version upgrade, the Bluetooth® functions are subject to change without notice. SUMMARY Table 2-1: Controller Core Specification Item Specification Name Core Spec Version 1.1, Adopted 5 Feb 2001 (Ver. 1.1) Core Spec Version 1.2, Adopted 5 Nov 2003 (Ver. 1.2) Core Spec Version 2.0, Adopted 4 Nov 2004 (Ver. 2.0) Core Spec Version 2.0 + EDR, Adopted 4 Nov 2004(Ver. 2.0 + EDR) Support No No No Yes Table 2-2: EDR Features Prerequisite: 2-1/4 (Ver. 2.0 + EDR) Item Feature EDR for asynchronous transports (single slot) EDR for asynchronous transports (multi-slot) EDR for synchronous transports Support Yes Yes Yes RF RF Capabilities (based on PICS proforma for Radio): Table A.1: RF Capabilities Item Capability Status Support Power Class (1,2 or 3) Power Control 1-slot packets supported 3-slot packets supported 5-slot packets supported 79 Channels Support for GFSK modulation Support for π/4-DQPSK modulation Support for 8DPSK modulation C.1 C.2 C.3 Yes Yes Yes Yes Yes Yes Yes Yes Yes Allowed 1 .. 3 Values Supported C.1: Mandatory to support if Power Class 1 is supported, optional to support if Power Class 2 or 3 is supported. C.2: Mandatory if SUMMARY, 2-1/4 is claimed; Optional if SUMMARY, 2-1/3 is claimed; Excluded otherwise. C.3: Mandatory if SUMMARY, 2-1/4 is claimed; Else Optional if (RF, 1/8 AND SUMMARY, 2-1/3) is claimed; Excluded otherwise. 25/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-D071063 Ver.0.1 (2/10) Control name Electrical characteristics Baseband Baseband Capabilities (based on PICS proforma for Baseband) Table B.1: Physical Channel Item Capability Support frequency band and 79 RF channels Adaptive Frequency Hopping Kernel Item Capability Basic Data Rate, 1 Mbps payload data rate Enhanced Data Rate, 2 Mbps payload data rate Enhanced Data Rate, 3 Mbps payload data rate Status Support Yes Yes Status C.1 C.2 Support Yes Yes Yes Table B.1a: Modulation schemes C.1: Mandatory if (SUMMARY, 2-1/4) is claimed; Optional if (SUMMARY, 2-1/3) is claimed; Excluded otherwise. C.2: Mandatory if (SUMMARY, 2-1/4) is claimed; Optional if (BB, 1a/2 AND SUMMARY, 2-1/3) is claimed; Excluded otherwise. Table B.2: Link Types Item Capability Support of ACL link Support of SCO link Support of eSCO link Support of Enhanced Data Rate ACL links Support of Enhanced Data Rate eSCO links Status C.1 C.2 Support Yes Yes Yes Yes Yes C.1: Mandatory IF (SUMMARY, 2-2/1 OR SUMMARY, 2-2/2) is claimed; ELSE Optional IF (SUMMARY, 2-1/3 OR SUMMARY, 2-1/4) is claimed; Excluded otherwise. C.2: Mandatory IF SUMMARY, 2-2/3 is claimed; ELSE Optional IF (SUMMARY, 2-1/3 OR SUMMARY, 2-1/4) is claimed; Excluded otherwise. Table B.3: SCO Link Support Prerequisite: B.2/2 (Support of SCO link) Item Capability Status Support SCO links to same Slave SCO links to different Slaves SCO links from same Master SCO links from different Masters C.1 C.1 Yes Yes Yes No Allowed 1 .. 3 1 .. 3 1.. 3 Values Supported Allowed (1 .. 6) (2 .. 5) (1 .. 6) (2 .. ) Values Supported C.1: Mandatory to support at least 1 link. Prerequisite: B.2/3 (Support of eSCO link) Item Capability Status Support eSCO links to same Slave eSCO links to different Slaves eSCO links from same Master eSCO links from different Masters C.2 C.2 Yes Yes Yes No C.2: Mandatory to support at least 1 link. 26/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-D071063 Ver.0.1 (3/10) Control name Electrical characteristics Table B.4: Common Packet Types Item Capability Support of ID packet type Support of NULL packet type Support of POLL packet type Support of FHS packet type Support of DM1 packet type Item Capability Support of DH1 packet type Support of DM3 packet type Support of DH3 packet type Support of DM5 packet type Support of DH5 packet type Support of AUX1 packet type Status Support Yes Yes Yes Yes Yes Status Support Yes Yes Yes Yes Yes Yes Table B.5: ACL Packet Types Table B.5a: Enhanced Data Rate ACL packet types Prerequisite: B.2/4 (Support of Enhanced Data Rate ACL links) Item Capability Support 2-DH1 packet type Support 2-DH3 packet type Support 2-DH5 packet type Support 3-DH1 packet type Support 3-DH3 packet type Support 3-DH5 packet type Status C.1 C.2 C.2 C.3 C.4 C.5 Support Yes Yes Yes Yes Yes Yes C.1: Mandatory IF (SUMMARY, 2-2/1 OR SUMMARY, 2-2/2) is claimed; ELSE Optional IF BB, 1a/2 is claimed; Excluded otherwise. C.2: Mandatory IF SUMMARY, 2-2/2 is claimed; ELSE Optional IF BB, 1a/2 is claimed; Excluded otherwise. C.3: Mandatory IF (SUMMARY, 2-2/1 OR SUMMARY, 2-2/2) is claimed; ELSE Optional IF BB 1a/3 is claimed; Excluded otherwise. C.4: Mandatory IF SUMMARY, 2-2/2 is claimed; ELSE Optional IF (BB, 5a/2 AND BB, 5a/4) is claimed; Excluded otherwise. C.5: Mandatory IF SUMMARY 2-2/2 is claimed; ELSE Optional IF (BB, 5a/3 AND BB, 5a/4) is claimed; Excluded otherwise. Table B.6: SCO and eSCO Packet Types Prerequisite for items 1-4: B.2/2 (Support of SCO link) Item Capability Support of HV1 packet type Support of HV2 packet type Support of HV3 packet type Support of DV packet type Status Support Yes Yes Yes Yes Status Support Yes Yes Yes Prerequisite for items 5-7: B.2/3 (Support of eSCO link) Item Capability Support of EV3 packet type Support of EV4 packet type Support of EV5 packet type 27/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-D071063 (4/10) Control name Electrical characteristics Table B.6a: Enhanced Data Rate eSCO packet types Prerequisite: B.2/5 (Support of Enhanced Data Rate eSCO links) Item Capability Support 2-EV3 packet type Support 2-EV5 packet type Support 3-EV3 packet type Support 3-EV5 packet type Status C.1 C.2 C.3 C.4 Support Yes Yes Yes Yes C.1: Mandatory IF SUMMARY, 2-2/3 is claimed; ELSE Optional IF BB, 1a/2 is claimed; Excluded otherwise. C.2:Optional IF BB, 1a/2 is claimed; Excluded otherwise. C.3: Mandatory IF SUMMARY, 2-2/3 is claimed; ELSE Optional IF BB, 1a/3 is claimed; Excluded otherwise. C.4: Optional IF BB, 1a/3 is claimed; Excluded otherwise. Table B.7: Page Procedures Item Capability Support paging Support page scan Status Support Yes Yes Supports Interlaced Scan during page scan Yes Item Capability Supports mandatory scan mode) Status Support Yes Item Capability Supports paging mode R0 Supports paging mode R1 Supports paging mode R2 Status C.1 C.1 C.1 Support Yes Yes Yes Status Support Yes Yes Yes Capability Support inquiry Inquiry scan with first FHS Status Support Yes Yes Supports the dedicated inquiry access code Supports Interlaced Scan during inquiry scan Yes Yes Table B.8: Paging Schemes Table B.9: Paging Modes C.1: At least one of the paging scan modes must be supported. Table B.9 (b): Paging Train Repetition Item Capability Supports Npage >= 1 Supports Npage >= 128 Supports Npage >= 256 Note: The master should use Npage >= 256 unless it knows what SR mode the slave uses. Table B.10: Inquiry Procedures Item 28/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-D071063 (5/10) Control name Electrical characteristics Table B.11: Piconet Capabilities Item Capability Status Support Broadcast messages Point-to-multipoint connections Yes Yes Allowed N/A (2 .. 7) Values Supported Table B.12: Scatternet Capabilities Item Capability Act as Master in one piconet and as Slave in another piconet Act as Slave in more than one piconet Status Support Yes Yes Table B.13: Synchronous Coding Schemes Prerequisite: B.2/2 (SCO link Support) Item Capability A-law u-law CVSD Transparent Synchronous Data Status Support Yes Yes Yes Yes Status Support Yes Yes Status Support Yes Yes Link Manager Link Manager Capabilities (based on PICS proforma for Link Manager) Table C.1: Response Messages Item Capability Accept message Reject message Item Capability 3-slot packets 5-slot packets Table C.2: Supported Features Encryption Yes 10 11 12 13 14 15 16 17 18 Slot offset Timing accuracy Role switch (Master/Slave) Hold mode Sniff mode Park mode Power Control Channel quality driven data rate SCO link RSSI Broadcast encryption eSCO link Adaptive frequency hopping Enhanced Data Rate ACL Enhanced Data Rate eSCO C.1 C.2 C.3 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes C.1: If Power Class 1 is supported (RF, 1/1=1) then Mandatory, else Optional. C.2: Mandatory IF (SUMMARY 2-2/1 OR SUMMARY 2-2/2) is claimed; ELSE Optional IF (SUMMARY 2-1/3 OR SUMMARY 2-1/4) is claimed; Excluded otherwise. C.3: Mandatory IF SUMMARY 2-2/3 is claimed; ELSE Optional IF (SUMMARY 2-1/3 OR SUMMARY 2-1/4) is claimed; Excluded otherwise. 29/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-D071063 Control name Electrical characteristics (6/10) Table C.3: Authentication Item Capability Initiate authentication before connection completed Initiate authentication after connection completed Respond to authentication request Status Support Yes Yes Yes Item Capability Initiate pairing before connection completed Initiate pairing after connection completed Respond to pairing request Use fixed PIN and request responder to initiator switch Use variable PIN Accept initiator to responder switch Status Support Yes Yes Yes C.1 Yes C.1 C.2 Yes Yes Capability Creation of link key - Unit Key Creation of link key - Combination Key Initiate change of link key Accept change of link key Status C.1 C.1 Support Yes Yes Yes Yes Accept pairing with Unit Key Yes Table C.4: Pairing C.1: Mandatory to support at least one of Pairing /4 and Pairing /5. C.2: Mandatory to support if Pairing /5 AND (Pairing /1 OR Pairing /2) is supported. Table C.5: Link Keys Item C.1: Mandatory to support at least one of the key types. Table C.6: Encryption Prerequisite: C.2/3 (Encryption supported) Item Capability Initiate encryption Accept encryption requests Status Support Yes Yes Key size negotiation Start encryption Accept start of encryption Stop encryption Accept stop of encryption Yes Yes Yes Yes Yes Item Capability Request clock offset information Respond to clock offset requests Status Support Yes Yes Table C.7: Clock Offset Information 30/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-D071063 (7/10) Control name Electrical characteristics Table C.8: Slot Offset Information Prerequisite: C.2/4 (Slot offset) Item Capability Send slot offset information Status C.1 Support Yes C.1: Mandatory to support if support if Role Switch/1 (Master/Slave switch) otherwise optional. Table C.9: Timing Accuracy Information Prerequisite: C.2/5 (Timing accuracy) Item Capability Request timing accuracy information Respond to timing accuracy information requests Item Capability Request LM version information Respond to LM version information requests Item Capability Request supported features Respond to supported features requests Request extended features mask Respond to extended features Request Status Support Yes Yes Status Support Yes Yes Status C.1 C.2 C.2 Support Yes Yes Yes Yes Table C.10: LM Version Information Table C.11: Feature Support C.1: Mandatory to support if any of the optional features in Supported Features /1-3, Supported Features /5, Supported Features /7-12, Supported Features /14-16, Adaptive Frequency Hopping /1 is requested by the IUT otherwise optional. C.2: Mandatory if a feature requiring another features page is supported, otherwise optional. Table C.12: Name Information Item Capability Request name information Respond to name requests Status Support Yes Yes Status Support Yes Yes Status Support Yes Table C.13: Role Switch Prerequisite: C.2/6 (Role switch) Item Capability Request Master Slave switch Accept Master Slave switch requests Item Capability Detach connection Table C.14: Detach 31/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-D071063 Ver.0.1 (8/10) Control name Electrical characteristics Table C.14a: Setting up and Removing Enhanced Data Rate ACL Connection Item Capability Enter Enhanced Data Rate Exit Enhanced Data Rate Status C.1 C.1 Support Yes Yes C.1: Mandatory if LMP, 2/17 supported, otherwise excluded. Table C.14b: Setting up and Removing Enhanced Data Rate eSCO Connection Item Capability Enter and exit eSCO using Enhanced Data Rate Packets Status Support C.1 Yes Status C.1 Support Yes Yes Yes Yes Capability Status Support Request sniff mode Respond to sniff mode requests (renegotiate or reject) Yes Yes Request un-sniff Accept un-sniff requests C.1 Yes Yes C.1: Mandatory if LMP, 2/18 supported, otherwise excluded. Table C.15: Hold mode Prerequisite: 2/7 (Hold mode) Item Capability Force hold mode Request hold mode Respond to hold mode requests Accept forced hold mode C.1: Mandatory to support if LMP, 15 /1 (Force hold mode) is supported, otherwise optional. Table C.16: Sniff mode Prerequisite: C.2/8 (Sniff mode) Item C.1: If LMP, 16/2 (Request sniff mode) is supported then mandatory to support, otherwise optional. Table C.17: Park mode Prerequisite: C.2/9 (Park Mode) Item 10 11 12 13 Capability Status Support Request park mode Respond to park mode requests Yes Yes Set up broadcast scan window Accept changes to the broadcast scan window Modify beacon parameters Accept modification of beacon parameters Request Unpark using PM_ADDR Request Unpark using BD_ADDR Slave requested Unpark Accept Unpark using PM_ADDR Accept Unpark using BD_ADDR C.1 C.1 Yes Yes Yes Yes Yes Yes Yes Yes Yes C.1: If LMP, 17/3 (Respond to park mode requests) is supported then at least one of LMP, 17 /9 (Unpark using PM_ADDR) or LMP, 17/10 (Unpark using BD_ADDR) is mandatory to support, otherwise optional. 32/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-D071063 (9/10) Control name Electrical characteristics Table C.18: Power Control Prerequisite: C.2/13 (RSSI) Item Capability Request to increase power Request to decrease power Status Support Yes Yes Status Support Yes Yes Status Support Yes Yes Status C.1 Support Yes Yes Yes Prerequisite: C.2/10 (Power control) Item Capability Respond when max power reached Respond when min power reached Item Capability Set link supervision timeout value Accept link supervision timeout setting Item Capability Channel quality driven change between DM and DH packet types Force/Request change of Quality of Service Request change of Quality of Service Table C.19: Link supervision Timeout Table C.20: Quality of Service C.1: Mandatory to support if support of LMP, 2 /11 is stated in the feature request, otherwise optional. Table C.21: SCO Links Prerequisite: C.2/12 (SCO link) Item Capability Initiate SCO links, as Master Initiate SCO links, as Slave Accept SCO links Remove SCO link, as Master Remove SCO link, as Slave Negotiate SCO link parameters, as Master Negotiate SCO link parameters, as Slave Status C.1 C.2 C.3 C.4 Support Yes Yes Yes Yes Yes Yes Yes C.1: Mandatory to support if LMP, 21 /1 (Initiating SCO links, as Master) is supported, otherwise optional. C.2: Mandatory to support if LMP, 21 /2 (Initiating SCO links, as Slave) is supported, otherwise optional. C.3: Mandatory to support if LMP, 21 /1 (Initiating SCO links, as Master) or LMP, 21/3 (Accept SCO links) is supported, otherwise optional. C.4: Mandatory to support if LMP, 21 /2 (Initiating SCO links, as Slave) or LMP, 21/3 (Accept SCO links) is supported, otherwise optional.Comments: Table C.22: Multi-Slot Packages Item Capability Accept maximum allowed number of slots to be used Request maximum number of slots to be used Accept request of maximum number of slots to be used Status C.1 C.1 C.1 Support Yes Yes Yes C.1: Mandatory to support if LMP, 2 /1 and/or LMP, 2 /2 is supported in the feature request, otherwise optional. 33/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AE-D071063 (10/10) Control name Electrical characteristics Table C.23: Paging Scheme Item Capability Request page mode to use Accept suggested page mode Request page scan mode to use Accept suggested page scan mode Item Capability Create connection for higher layers Respond to requests to establish connections for higher layers Indicate that link set-up is completed Item Capability Activate test mode Ability to reject activation of test mode if test mode is disabled Control test mode Ability to reject test mode control commands if test mode is disabled. Status Support Yes Yes Yes Yes Status Support Yes Yes Yes Status Support Yes Yes Yes Yes Table C.24: Connection Establishment Table C.25: Test Mode Table C.26: Adaptive Frequency Hopping Prerequisite: C.2/20 (AFH) Item Capability Support of AFH switch as master Support of AFH switch as slave Support of Channel Classification reporting as master Support of Channel Classification reporting as slave Support channel classification from host Support of Channel Classification Status C.1 C.2 C.3 Support Yes Yes Yes Yes Yes Yes C.1: Optional if LMP, 26/6 is supported, otherwise excluded. C.2: Mandatory if LMP, 26/6 is supported, otherwise excluded. C.3: Mandatory if LMP, 26/1 or LMP, 26/4 is supported, otherwise optional. Notes: This Data Report is based on “1846_BC4-Ext_RF.ICS-2.0.E.0”, “1847_HCIStack2.0EDR_BB.ICS-2.0.E.0”, “1848_HCIStack2.0EDR_LMP.ICS-2.0.E.0”and “SUM.ICS-2.0.E.4”. 34/40 TAIYO YUDEN 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-MC-A071063 Control name Circuit Schematic (1/1) Block Diagram CRYSTAL 26 MHz 32Kbit EEPROM Antenna Baseband Balun filter Connector RF Bluetooth Device Micro controller LDO GND USB_DETACH /RESET USB DUSB D+ VDD 35/40 TAIYO YUDEN 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AD-A071063 Ver.0.1 (1/1) Control name Outline/Appearance Unit: mm, Tolerances unless otherwise specified: +/-0.2mm Note: Outline/Appearance data is PRELIMINARY, not guaranteed and subject to change without notice. Please contact Taiyo Yuden for the details of module mountings. TAIYO YUDEN 36/40 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-AD-B071063 Control name Outline/Appearance (1/1) Indication label Label1 Case-side (ケース側 1 枚目) Product Number:EYSMJCS 2.4FH1 EYSMJCSFX 201 WW 07215204 CA46920-0316 01A Taiyo Yuden Co.,Ltd. Label2 Case-side ABCDEFGHIJK (ケース側 2 枚目) IC: 4389B-EYSMJCS FCC ID:RYYEYSMJCS Label3 Back-side XXX-XXXXXXX (基板側) LOT.No 00037AAAAAAA Material: PET ( UL969 ) / Label color : White TAIYO YUDEN 37/40 24-Aug.-2007 TAIYO YUDEN Confidential & Tentative EYSMJCS Control No. HD-BA-A071063 Ver.0.1 (1/1) Control name Pin Layout Pin Descriptions Terminal No. Terminal name Input/Output Description GND PIO2/USB_DETACH Input /RESET Input USB_D- Input/Output USB data (Negative) input-output USB_D+ Input/Output USB data (Positive) input-output VDD Input Remark Ground DETACH signal input Low USB connect High USB disconnect Active low RESET signal with internal weak pull-up DC3.3V Power supply Note 1 Note 2 Note 3 Notes: 1. Strength pull-downs (pull-ups) are equivalent to a few kOhms resistance, but are more accurately modeled as a 40uA current drain (source). 2. Weak pull-ups can be thought of 1M Ohm connections to VDD, but are more accurately modeled as a -1uA current source. 3. Pin 6 (VDD) is used for power supply of BT module. To fill the standard of “Supply voltage ripple and spike noise”, the capacitor, which has the capacity of 2.2uF or more, should be put in the terminal VDD outside as a bypass capacitor. TAIYO YUDEN 38/40 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS FCC Regulatory Information CAUTION: To maintain compliance with FCC’s RF exposure guidelines, use only the supplied antenna. Unauthorized antenna, modification, or attachments could damage the transmitter and may violate FCC regulations. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may Cause undesired operation. Canada Regulatory Information Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. L'utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et (2) l'utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. R&TTE Directive Information Hereby Taiyo Yuden Co., Ltd., declares that this Complete Class2 Bluetooth Module (Model No.: EYSMJCS) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC Caution Please note that this users manual should not be provided to end-users. TAIYO YUDEN 39/40 24-Aug.-2007 Ver.0.1 TAIYO YUDEN Confidential & Tentative EYSMJCS Notice At the use of our Module, following is required to be shown under the responsibility of the manufacture who integrates it into their device. The following sentence has to be displayed on the outside of the device in which the module is installed: "Contains Transmitter Module FCC ID: RYYEYSMJCS ", or "Contains IC: 4389B-EYSMJCS " FCC Regulatory information CAUTION: To maintain compliance with FCC’s RF exposure guidelines, use only the supplied antenna. Unauthorized antenna, modification, or attachments could damage the transmitter and may violate FCC regulations. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may Cause undesired operation. Canada Regulatory information Operation is subject to the following two conditions: (3) this device may not cause interference, and (4) this device must accept any interference, including interference that may cause undesired operation of the device. L'utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (3) il ne doit pas produire de brouillage et l'utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. R&TTE Directive information Hereby [Name of manufacture(*)], declares that this [type of equipment(*)] is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC (*) Note: Please write in your company name and type of equipment into [ ]. TAIYO YUDEN 40/40
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Warning : Error loading Encrypt objectEXIF Metadata provided by EXIF.tools