TAIYO YUDEN EYSMJCS Complete Class 2 Bluetooth Module User Manual

Taiyo Yuden Co., Ltd. Complete Class 2 Bluetooth Module

user manual

Download: TAIYO YUDEN EYSMJCS Complete Class 2 Bluetooth Module User Manual
Mirror Download [FCC.gov]TAIYO YUDEN EYSMJCS Complete Class 2 Bluetooth Module User Manual
Document ID853798
Application IDdg8S+zYLNbkcqDBMIVuyxg==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize46.18kB (577302 bits)
Date Submitted2007-10-12 00:00:00
Date Available2007-10-12 00:00:00
Creation Date2017-11-26 06:36:57
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-11-26 06:36:57
Document Titleuntitled

24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Bluetooth® Module
EYSMJCS (RF+Baseband (Class 2) USB)
User’s Manual
In case you adopt this module and design some appliance, please
ask for the latest specifications from the local sales office.
We wish the customer to request the Specification Report when the
design for the mass production begins because the content of this
Data Report might change without a previous notice to the customer.
The Bluetooth® word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks
by TAIYO YUDEN CO., LTD. is under license.
1/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Document constituent list
Control name
General Items
Absolute maximum ratings
Electrical characteristics
Electrical characteristics
Electrical characteristics
Electrical characteristics
Circuit schematic
Outline / Appearance
Outline / Appearance
Pin Layout
Control No.
HD-AG-A071063
HD-AM-A071063
HD-AE-A071063
HD-AE-B071063
HD-AE-C071063
HD-AE-D071063
HD-MC-A071063
HD-AD-A071063
HD-AD-B071063
HD-BA-A071063
Document Page
1/3 – 3/3
1/1
1/3- 3/3
1/2 - 2/2
1/13 - 13/13
1/10- 10/10
1/1
1/1
1/1
1/1
Rev. record
24-Aug.-2007> Ver.0.1
2/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
Control name
HD-AG-A071063
(1/3)
General Items
Scope
This specification (“Specification”) applies to the hybrid IC “EYSMJCS” for use Bluetooth® module
(“Product”) manufacture by TAIYO YUDEN Co., Ltd. (“TAIYO YUDEN”)
1. User’s Code: EYSMJCS (USB I/F Support)
Type: EYSMJCS
2. Function: Radio frequency transfer Module (power class 2). Bluetooth® standard Ver 2.0+EDR conformity
3. Application: Laptop PC
4. Structure: Hybrid IC loaded with silicon monolithic semiconductor
5. Outline: FFC/FPC Connector Type
6. Marking: TBD
7. Features:
-Bluetooth® 2.0+EDR conformity
-USB Interface
-Point-to-Multipoint (7 Slaves)
-Encryption
-Hold, Sniff and Park Mode
-Supported Link Type: ACL
-AFH
-EDR (Enhanced Data Rate)
8. Packing: TBD
9. Terminal: Data input-output (6pin Cable Connector)
RF input-output (Antenna)
10. Mount: TBD
11. Notes:
a. Any question arising from this Specification shall be solved through mutual discussion by the parties
hereof.
b. This Product is not designed for radiation durable and should not be used under the circumstance of
radiation.
3/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AG-A071063
Ver.0.1
(2/3)
Control name
General Items
c. The operating conditions of this Product are as shown in this Specification. Please note that TAIYO
YUDEN shall not be liable for a failure and/or abnormality which is caused by use under the conditions
other than the operating conditions hereof.
d. This Product mentioned in this Specification is manufactured for use in Laptop PC. Before using this
Product in any special equipment (such as medical equipment, space equipment, air craft, disaster
prevention equipment), where higher safety and reliability are duly required, the applicability and
suitability of this Product must be fully evaluated by the customer at its sole risk to ensure correct and
safety operation of those special equipments. Also, evaluation of the safety function of this Product even
for use in general electronics equipment shall be thoroughly made and when necessary, a protective circuit
shall be added in design stage, all at the customer’s sole risk.
e. TAIYO YUDEN warrants only that this Product is in conformity with this Specification for one year after
purchase and shall in no event give any other warranty.
f. The warranty period shall be one year.
g. Communication between this Product and others might not be established nor maintained depending upon
radio environment or operating conditions of this Product and other Bluetooth® products.
h. This Product is designed for use in products which comply with Bluetooth® Specifications (Ver 2.0+EDR)
(“Bluetooth Specifications”). TAIYO YUDEN disclaims and is not responsible for any liability concerning
infringement by this Product under any intellectual property right owned by third party in case the
customer uses this Product in any product which does not comply with Bluetooth Specifications (the
“non-complying products”). Furthermore, TAIYO YUDEN warrants only that this Product complies with
this Specification and does not grant any other warranty including warranty for application of the
non-complying products.
i. TAIYO YUDEN dose not render updating or upgrading service for the firmware in the Module.
j. In order to take tests for getting the certification of each country’s Radio Law with a device incorporating
this module, it is necessary to make the software in Host to put the module into test condition. Please
contact TAIYO YUDEN for farther details.
k. Please evaluate adequately our module incorporated to your products before mass production.
l. This Product operates in the unlicensed ISM band at 2.4GHz. In case this Product is used around the other
wireless devices which operate in same frequency band of this Product, there is a possibility that
interference occurs between this Product and such other devices. If such interference occurs, please stop
the operation of other devices or relocate this Product before using this Product or do not use this Product
around the other wireless devices.
4/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AG-A071063
Ver.0.1
(3/3)
Control name
General Items
m. Containment of hazardous substance in this Product
*Pb (Lead)
: Non use
*Additional RoHS regulation substance (Cd.Hg.Cr+6.PBB.PBDE) :Non use
n. In addition when this Product is used under environmental conditions such as over voltage which
are not guaranteed ,it may be destroyed in short mode. To ensure the security of customer’s product,
please add an extra fuse or/and a protection circuit for over voltage.
p. In some cases, TAIYO YUDEN may use replacements as component parts of Products. Such
replacement shall apply only to component part of Products, which TAIYO YUDEN deems it
possible to replace or substitute according to (i) Scope provided in this Specification (e.g.
Official Standard (Type Approvals, Bluetooth LOGO etc.)) and (ii) Quality of Products. TAIYO
YUDEN also ensures traceability of such replacement on production lot basis.
r. Do not alter Hardware and/or Software of this Product.
Please note that TAIYO YUDEN shall not be liable for any problem if it is caused by customer's
alteration of Hardware or/and Software without Taiyo Yuden's prior approvals.
This module is still under development, thus specifications do not guarantee both the quality and
reliability at the time of shipment. Since the specifications and mass production of the module are not
confirmed either, the contents of the technical notes are subject to change without any prior notice.
5/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AM-A 071063
Control name
Absolute maximum ratings
(1/1)
Absolute maximum ratings
Item
Supply voltage
Input voltage
Symbol
Min.
Typ.
Rating
Max.
Remark
Unit
VDD
-0.3
3.6
Vin
-0.3
VDD+0.3
Ta=25 degrees C,
GND reference
I/O terminals except
USB interface
Recommendation operating range
Item
Symbol
Supply voltage
Supply voltage ripple
and spike noise
Operation temperature
range
Storage temperature
range
VDD
Min.
3.15
Rating
Typ.
Max.
3.3
3.45
VDD_rn
Unit
(30)
mVp-p
Topr
25
70
Degrees C
Tstg
-30
25
85
Degrees C
Remark
Note 1
Humidity=40%RH
Note 2
Humidity=40%RH
Note 3
Notes:
1. To fill the standard of “Supply voltage ripple and spike noise”, the capacitor, which has the capacity of
2.2uF or more, should be put in the terminal VDD outside as a bypass capacitor .
2. Operating temperature range is set to satisfy products electrical characteristics in the short term.
In terms of product life cycle when it is used in condition of varying from TYP standard in the long term,
please refer to the reliability condition.
3. Storage temperature range is the condition for transportation and storage in temporary.
6/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-A071063
Electrical characteristic
(1/3)
Control name
Electrical characteristics
DC Specifications
The Specification applies for Topr.= 25 degrees C, VDD=3.3V
No.
Parameter
Condition
Normal supply voltage
Input Low Voltage 1
Input Low Voltage 2
Input High Voltage 1
Input High Voltage 2
Output Low Voltage 1
Output Low Voltage 2
Output High voltage 1
Output High voltage 2
/RESET, PIOX
USB_D+, USB_D/RESET, PIOX
USB_D+, USB_DPIOX
USB_D+, USB_DPIOX
USB_D+, USB_D-
Symbol
VDD
VIL1
VIL2
VIH1
VIH2
VOL1
VOL2
VOH1
VOH2
Min.
3.15
-0.3
0.7xVDD
2.0
VDD-0.4
2.8
Typ.
3.3
Max.
3.45
0.8
0.8
VDD+0.3
0.4
0.3
Unit
Remark
V IOL=4mA
V IOH=-4mA
mA Notes 3, 4
10 Peak current
Continuous Rx
Iccp1
(42)
(120)
11 Average current1
12 Average current2
Sniff mode (Slave only)
Standby mode
Icca1
Icca2
(10)
(9)
13 Average current3
Send DM1packet (Master)
Icca3
(36)
mA Notes 1, 3, 4
mA Notes 3, 4
mA Notes 3, 4
14 Average current4
15 Average current5
16 Average current6
Receive DM1packet (Slave)
Hold mode (Slave only)
Park mode (Slave only)
Icca4
Icca5
Icca6
(37)
(9)
(9)
mA Notes 3, 4
mA Notes 3, 4
mA Notes 2, 3, 4
Notes:
1. Sniff mode parameter.
Max interval 0050h
Min interval 0010h
Attempt
0005h
Timeout
0005h
2. Park mode parameter.
Max interval 0100h
Min interval 0010h
3. The consumption current might fluctuate with the condition of radio communication, host performance
and test circuit.
4. The value may fluctuate several (mA) depending on Firmware version.
7/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
Control name
HD-AE-A071063
(2/3)
Electrical characteristics
AC Specifications
The Specification applies for Topr.= 25 degrees C, VDD=3.3V
No.
Parameter
Condition
Symbol
Min
Typ
Max
Unit
ms
Note 1
ms
Note 2
ms
Notes 3, 4
VDD Rise Time from 0V to 3.15V
t1
VDD= 3.15V to /RESET High
t2
10
/RESET High to Module Ready
t3
/RESET Pulse Width
t4
DETACH High to USB I/F High-Z
t5
DETACH Low to USB I/F Active
t6
/RESET High to /RESET Low
t7
3000
/RESET Low to USB_I/F High-Z
t8
Module Active to /RESET Low
t9
ms
10 /RESET Low to VDD_3.3V Off
t10
ms
(100)
3000
Remark
ms
130
ms
10
ms
ms
10
Note 5
ms
Note 5
Notes:
1. This module has an internal flash memory and a function to erase/sort unnecessary data if certain HCI commands
are issued and consume more than a certain level of free space in the flash memory. This operation occurs at every
module initialization (power-on).
If supply voltage becomes non-defined states during initialization or writing in flash memory, data in flash memory
might be destroyed. If the data in flash memory is destroyed, module will not work correctly. Therefore please be
sure to stabilize power source before /RESET release.
In addition please design module peripheral circuits to avoid temporary blackout of power source during operation.
Please refer HD-AE-C 071063 for HCI command which rewrites flash memory data.
2. Input /RESET signal of 10ms and more in condition of VDD_3.3V at over 3.15V.
3. When the module is ready to accept the command, its module outputs the “0F 04 00 01 00 00” (Hex) USB to the
Data Line. After that, please access to the module.
4. The Typ. is a reference value. The value may change depending on the firmware version and conditions of use.
5. You don’t need to wait t6 if you confirm that this module has output “0F 04 00 01 00 00” (Hex).
8/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-A071063
Control name
Electrical characteristics
(3/3)
VDD
t2
t7
t1
/RESET
(Note 1)
t4
USB_DETACH
t3
t9
t8
t5
Active
USB_I/F
Active
t6
Active
Timing Diagram for Power Up Sequence
VDD_3.3V
t10
/RESET
(Note 1)
USB_DETACH
USB_I/F
Active
Timing Diagram for Power Down Sequence
9/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-B071063
(1/2)
Control name
Electrical characteristics
RF Specifications at Basic Rate
The Specification applies for Ta=25 degrees C, VDD=3.3V
No. Parameter
Condition
Symbol Min
Typ
Max
Unit
FREQ
PO
2400
-6
2483.5 MHz
+4
dBm
dF1: F0(11110000)
M1
140
dF2: AA(10101010)
M4
115
dF2/dF1
MC
0.8
2MHz(|M-N|=2)
ISE1
-20
dBm
3MHz or greater
(|M-N|>=3)
ISE2
-40
dBm
Remark
10
11
12
13
14
15
Frequency band
Tx power
Modulation
characteristics 1
Modulation
characteristics 2
Modulation
characteristics 3
In-band
spurious
emission 2
spurious
In-band
emission 3
Initial Carrier
Frequency
Frequency Drift 1
Frequency Drift 2
Drift rate
C/I co-channel
C/I 1MHz
C/I 2MHz
C/I >= 3MHz
16
C/I Image
CI4
-9
dB
17
C/I Image +/- 1MHz
Out-of-Band
Blocking 1
Out-of-Band
Blocking 2
Out-of-Band
Blocking 3
CI5
-20
dB
OBB1
-10
dBm
OBB2
-27
dBm
OBB3
-27
dBm
OBB4
-10
dBm
BER<=0.1
dBm
BER<=0.1
18
19
20
21
Out-of-Band
Blocking 4
23
Maximum Input
Level
20dB Bandwidth
24
Sensitivity-single
25
Sensitivity-multi
22
DH1
DH3,DH5
DH1,DH3,DH5
30MHz to 2000MHz
f=2460MHz
2000 to 2399MHz
f=2460MHz
2484 to 3000MHz
f=2460MHz
3000MHz to
12.75GHz
f=2460MHz
175
kHz
kHz
ICF
-75
+75
kHz
FD1
FD2
DR
CIC
CI1
CI2
CI3
-25
-40
+25
+40
400
11
-30
-40
kHz
kHz
Hz/us
dB
dB
dB
dB
MAXP -20
B20
MHz
DH1
SEN1
-70
dBm
DH3,DH5
SEN2
-70
dBm
-60dBm
-60dBm
-60dBm
-67dBm
-3MHz
offset
-67dBm
-67dBm
BER<=0.1
BER<=0.1
BER<=0.1
BER<=0.1
BER<=0.1
10/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-B071063
(2/2)
Control name
Electrical characteristics
RF Specifications at EDR
The Specification applies for Ta=25 degrees C, VDD =3.3V
No. Parameter
Condition
Symbol
Min
Typ
Max
Unit
Pai/4DQPSK
8DPSK
Pai/4DQPSK
8DPSK
Pai/4DQPSK
8DPSK
RDE1
RDE2
PDE1
PDE2
D991
D992
|M-N|=1
EISE1
|M-N|=2
EISE2
-20
dBm
|M-N|=3
EISE3
-40
dBm
-75
+75
kHz
-10
PGFSK
-4
+10
PGFSK
+1
kHz
15
16
17
18
RMS DEVM 1
RMS DEVM 2
Peak DEVM 1
Peak DEVM 2
99% DEVM 1
99% DEVM 2
EDR In-band spurious
emission 1
EDR In-band spurious
emission 2
EDR In-band spurious
emission 3
EDR Initial Carrier
Frequency
EDR Drift
Relative transmit
power
Actual Sensitivity
Level
BER Floor
Performance
C/I co-channel
C/I 1MHz
C/I 2MHz
C/I >= 3MHz
19
C/I Image
20
21
22
23
24
10
11
12
EICF
ED
PDPSK
RTP
2-DH5(3-DH5)
16000000bit
2-DH5(3-DH5)
160000000bit
2-DH5
2-DH5
2-DH5
2-DH5
Remark
0.20
0.13
0.35
0.25
0.30
0.20
26
dB
dB
ESEN
-70
dBm BER= 10-4
FSEN
-60
dBm BER= 10-5
2CIC
2CI1
2CI2
2CI3
13
-30
-40
dB
dB
dB
dB
2-DH5
2CI4
-7
dB
C/I Image +/- 1MHz
C/I co-channel
C/I 1MHz
C/I 2MHz
C/I >= 3MHz
2-DH5
3-DH5
3-DH5
3-DH5
3-DH5
2CI5
3CIC
3CI1
3CI2
3CI3
-20
21
-25
-33
dB
dB
dB
dB
dB
25
C/I Image
3-DH5
3CI4
dB
26
C/I Image +/- 1MHz
3-DH5
-13
dB
27
Maximum Input Level 2-DH5(3-DH5)
3CI5
EMAX
13
14
-20
-60dBm
-60dBm
-60dBm
-67dBm
-67dBm
-3MHz
offset
-67dBm
-60dBm
-60dBm
-60dBm
-67dBm
-67dBm
-3MHz
offset
-67dBm
dBm
Note:
Bluetooth® standard Ver 2.0+EDR conformity
11/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
Control name
HD-AE-C071063
(1/13)
Electrical characteristics
Supported HCI Commands / HCI Events
The Bluetooth® functions of this module is as written in the attached PICS. Depending on
firmware version Upgrade, the Bluetooth® functions are subject to change without notice.
HCI COMMAND LIST
Firmware Version 21e (Build3164)
OpCode
Group
(Hex)
Command
(Hex)
Parameters
HCI _Inquiry
0x0401
LAP
Inquiry Length
Num Responses
HCI _ Inquiry_ Cancel
0x0402
Command Description
Returns
Status
Notes
LINK CONTROL
Inquiry
HCI_ Periodic_ Inquiry _Mode
0x0403
HCI _Exit _Periodic _Inquiry _Mode
0x0404
Max Period Length
Min Period Length
LAP
Inquiry Length
Num Responses
Yes
Status
Yes
Status
Yes
Status
Yes
Connection Management
HCI _Create_ Connection
0x0405
HCI _Disconnect
0x0406
HCI _Add _SCO _Connection
0x0407
HCI _Create _Connection _Cancel
0x0408
HCI _Accept _Connection _Request
0x0409
HCI _Reject _Connection _Request
HCI _Change _Connection _Packet
_Type
0x040A
0x040F
HCI _Setup _Synchronous
_Connection
0x0428
28
HCI _Accept _Synchronous
_Connection _Request
0x0429
29
HCI _Reject _Synchronous
_Connection _Request
0x042A
2A
BD ADDR
Packet Type
Page Scan Repetition Mode
Page Scan Mode
Clock Offset
Allow Role Switch
Connection Handle
Reason
SCO Handle
Packet Type
BD ADDR
BD ADDR
Role
BD ADDR
Connection Handle
Packet Type
Connection_Handle
Transmit_Bandwidth
Receive_Bandwidth
Max_Latency
Voice_Setting
Retransmission_Effort
Packet_Type
BD ADDR
Transmit_Bandwidth
Receive_Bandwidth
Max_Latency
Content Format
Retransmission_Effort
Packet_Type
BD ADDR
Reason
Status
BD_ADDR
Yes
a,b
Yes
Yes
b,c,
d,j,p
Yes
Yes
Yes
Yes
Yes
l,m,
o,p
Yes
l,m,o
Yes
l,m,o
12/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
Control name
Electrical characteristics
(2/13)
Authentication / Pairing
HCI _Link _Key _Request _Reply
0x040B
BD ADDR
Link Key
HCI _Link _Key _Request
_Negative _Reply
0x040C
BD ADDR
HCI _PIN _Code _Request _Reply
0x040D
BD ADDR
PIN Code Length
PIN Code
0x040E
BD ADDR
HCI _PIN _Code _Request
_Negative _Reply
HCI _Authentication _Requested
HCI _Change _Connection _Link
_Key
Status
BD ADDR
Status
BD ADDR
Status
BD ADDR
Yes
Status
BD ADDR
Yes
Yes
Yes
0x0411
11
Connection Handle
Yes
0x0415
15
Connection Handle
Yes
HCI _Set _Connection _Encryption
0x0413
13
HCI _Master _Link _Key
0x0417
17
Encryption
Connection Handle
Encryption Enable
Key Flag
Yes
Yes
Remote Information
HCI _Remote _Name_ Request
HCI _Remote _Name _Request
_Cancel
HCI _Read _Remote _Supported
_Features
HCI _Read _Remote _Extended
_Features
HCI _Read _Remote _Version
_Information
HCI _Read _Clock _Offset
HCI _Read _LMP _Handle
0x0419
19
BD ADDR
Page Scan Repetition Mode
Page Scan Mode
Clock Offset
0x041A
1A
BD_ADDR
0x041B
1B
Connection Handle
Yes
Yes
Yes
0x041C
1C
Connection Handle
Page_Number
0x041D
1D
Connection Handle
0x041F
1F
Connection Handle
0x0420
20
Connection Handle
Yes
Status
BD_ADDR
Yes
Yes
Status
Connection Handle
LMP_Handle
Reseved
Yes
13/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
Control name
Electrical characteristics
(3/13)
LINK POLICY
Connection Handle
Hold Mode Max Interval
Hold Mode Min Internal
Connection Handle
Sniff Mode Max Interval
Sniff Mode Min Interval
Sniff Attempt
Sniff Timeout
Connection Handle
Connection Handle
Beacon Max Interval
Beacon Min Interval
Connection Handle
Connection Handle
Flags
Service Type
Token Rate
Peak Bandwidth
Latency
Delay Variation
HCI _Hold _Mode
0x0801
HCI _Sniff _Mode
0x0803
HCI _Exit _Sniff _Mode
0x0804
HCI _Park _State
0x0805
HCI _Exit _Park _State
0x0806
HIC _QoS _Setup
0x0807
HCI _Role _Discovery
0x0809
Connection Handle
HCI _Switch _Role
0x080B
BD ADDR
Role
HCI _Read _Link _Policy _Settings
0x080C
Connection Handle
HCI _Write _Link _Policy _Settings
0x080D
Connection Handle
Link Policy settings
HCI _Read _Default _Link _Policy
_Settings
0x080E
HCI _Write _Default _Link _Policy
_Settings
0x080F
HCI _Flow _Specification
0x0810
10
Default Link Policy
Settings
Connection Handle
Flags
Flow direction
Service Type
Token Rate
Token Bucket Size
Peak Bandwidth
Access Latency
Yes
Yes
Yes
Status
Connection Handle
Current Role
Yes
Yes
Yes
e,m
Yes
Yes
States
Connection Handle
Link Policy Settings
States
Connection Handle
Status
Default Link Policy
Settings
Status
Yes
Yes
Yes
Yes
No
l,m
14/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
(4/13)
Control name
Electrical characteristics
HOST CONTROLLER & BASEBAND
HCI _Set _Event _Mask
HCI _Reset
0x0C01
0x0C03
Event Mask
HCI _Set _Event _Filter
0x0C05
Filter Type
Filter Condition Type
Condition
HCI _Flush
0x0C08
Connection Handle
HCI _Read _PIN _Type
0x0C09
HCI _Write _PIN _Type
HCI _Create _New _Unit _Key
0x0C0A
0x0C0B
HCI _Read _Stored _Link _Key
0x0C0D
HCI _Write _Stored _Link _Key
0x0C11
11
HCI _Delete _Stored _Link _Key
0x0C12
12
HCI _Write _Local _Name
0x0C13
13
HCI _Read _Local _Name
0x0C14
14
0x0C15
15
0x0C16
16
HCI _Read _Page _Timeout
0x0C17
17
HCI _Write _Page _Timeout
0x0C18
18
HCI _Read _Scan _Enable
0x0C19
19
HCI _Write _Scan _Enable
0x0C1A
1A
HCI _Read _Page _Scan _Activity
0x0C1B
1B
HCI _Write _Page _Scan _Activity
0x0C1C
1C
HCI _Read _Inquiry _Scan _Activity
0x0C1D
1D
HCI _Write _Inquiry _Scan _Activity
0x0C1E
1E
HCI _Read _Authentication _Enable
0x0C1F
1F
HCI _Write _Authentication _Enable
0x0C20
20
HCI _Read _Encryption _Mode
0x0C21
21
HCI _Write _Encryption _Mode
0x0C22
22
HCI _Read _Class _of _Device
0x0C23
23
HCI _Write _Class _of _Device
0x0C24
24
HCI _Read _Voice _Setting
0x0C25
25
HCI _Write _Voice _Setting
0x0C26
26
PIN Type
BD ADDR
HCI _Read _Connection _Accept
_Timeout
HCI _Write _Connection _Accept
_Timeout
Read All Flag
Num Keys To Write
BD ADDR [I]
Link Key [I]
BD ADDR
Delete All Flag
Local Name
Conn Accept Timeout
Page Timeout
Scan Enable
Page Scan Interval
Page Scan Window
Inquiry Scan Interval
Inquiry Scan Window
Authentication Enable
Encryption Mode
Class of Device
Voice Channel setting
States
States
Yes
Yes
States
Yes
States
Connection Handle
States
PIN Type
States
States
States
Max Num Keys
Num Keys Read
States
Num Keys Written
States
Num Keys Deleted
States
States
Local Name
States
Conn Accept Timeout
States
States
Page Timeout
States
States
Scan Enable
States
States
Page Scan Interval
Page Scan Window
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
f,k
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
States
Yes
States
Inquiry Scan Interval
Inquiry Scan Window
Yes
States
Yes
States
Authentication Enable
States
States
Encryption Mode
States
States
Class of Device
States
States
Voice Setting
States
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
15/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
HCI _Read _Automatic _Flush
_Timeout
HCI _Write _Automatic _Flush_
Timeout
HCI _Read _Num _Broadcast_
Retransmission
HCI _Write _Num _Broadcast_
Retransmission
(5/13)
Control name
Electrical characteristics
0x0C27
27
Connection Handle
0x0C28
28
Connection Handle
Flash Timeout
0x0C29
29
Num Broadcast
Retransmission
0x0C2A
2A
HCI _Read _Hold _Mode _Activity
0x0C2B
2B
HCI _Write _Hold _Mode _Activity
0x0C2C
2C
HCI _Read _Transmit _Power
_Level
0x0C2D
2D
HCI _Read _Synchronous _Flow
_Control _Enable
0x0C2E
2E
0x0C2F
2F
Synchronous Flow
Control Enable
0x0C31
31
Flow Control Enable
HCI _Write _ Synchronous _Flow
_Control _Enable
HCI _Set _Controller _To _Host
_Flow _Control
Hold Mode Activity
Connection Handle
Type
Host ACL Data Packet
Length
Host SCO Data Packet
Length
Host Total Num ACL Data
Packets
Host Total Num SCO Data
Packets
Number of Handles
Connection handle [I]
Host Num of Completed
Packets [I]
HCI _Host _Buffer _Size
0x0C33
33
HCI _Host _Number _Of
_Completed _Packets
0x0C35
35
HCI _Read _Link _Supervision
_Timeout
0x0C36
36
Connection Handle
0x0C37
37
Connection Handle
Link Supervision Timeout
0x0C38
38
HCI _Read _Current _IAC _LAP
0x0C39
39
HCI _Write _Current _IAC _LAP
0x0C3A
3A
0x0C3B
3B
0x0C3C
3C
0x0C3D
3D
HCI _Write _Link _Supervision
_Timeout
HCI _Read _Number _Of _Support
_IAC
HCI _Read _Page _Scan _Period
_Mode
HCI _Write _Page _Scan _Period
_Mode
HCI _Read _Page _Scan _Mode
HCI _Write _Page _Scan _Mode
HCI _Set _AFH _Host _Channel
_Classification
Ver.0.1
0x0C3E
3E
0x0C3F
3F
Num Current IAC
IAC LAP [I]
Page Scan Period Mode
Page Scan Mode
AH Host Channel
Classification
States
Connection Handle
Flush Timeout
States
Connection Handle
Yes
Yes
States
Yes
States
Yes
States
Hold Mode Activity
States
States
Connection Handle
Power Level
States
Synchronous Flow
Control Enable
Yes
Yes
Yes
No
c,d,k
States
No
c,d,k
States
Yes
States
Yes
Yes
States
Connection Handle
Link Supervision
Timeout
States
Connection Handle
States
Num Support IAC
States
Num Current IAC
IAC LAP [I]
Yes
Yes
Yes
Yes
States
Yes
States
Page Scan Period Mode
Yes
States
Yes
States
Page Scan Mode
States
Status
Yes
Yes
h,j
Yes
16/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
(6/13)
HCI _Read _Inquiry _Scan _Type
0x0C42
42
HCI _Write _Inquiry _Scan _Type
0x0C43
43
HCI _Read _Inquiry _Mode
0x0C44
44
HCI _Write _Inquiry _Mode
0x0C45
45
HCI _Read _Page _Scan _Type
0x0C46
46
HCI _Write _Page _Scan _Type
0x0C47
47
HCI _Read _AFH _Channel
_Assessment _Mode
0x0C48
48
HCI _Write _AFH _Channel
_Assessment _Mode
0x0C49
49
Control name
Electrical characteristics
Inquiry Scan Type
Inquiry Mode
Page Scan Type
AFH Channel
Assessment Mode
Status
Inquiry Scan Type
Status
Status
Inquiry Mode
Status
Status
Page Scan Type
Status
Status
AFH Channel
Assessment Mode
Status
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
INFORMATIONAL PARAMETERS
HCI _Read _Local _Version _
Information
0x1001
0x1002
0x1003
HCI _Read _Local _Extended
_Features
0x1004
HCI _Read _Buffer _Size
0x1005
HCI _Read _Country _Code
0x1007
HCI _Read _BD _ADDR
0x1009
HCI _Read _Local _Supported
_Commands
HCI _Read _Local _Supported
_Features
Page number
Status
HCI Version
HCI Revision
LMP Version
Manufacturer Name
LMP Subversion
Status
Supported Commands
Status
LMP_Features
Status
Page number
Maximum Page Number
Extended LMP Features
Status
HC ACL Data Packet
Length
HC Synchronous Data
Packet Length
HC Total Num ACL
Data Packet
HC Total Num
Synchronous Data Packe
Status
Country Code
Status
BD ADDR
Yes
Yes
Yes
Yes
Yes
Yes
Yes
17/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
Control name
Electrical characteristics
(7/13)
STAUS PARAMETERS
HCI _Read _Failed _Contact
_Counter
0x1401
Connection Handle
HCI _Reset _Failed _Contact
_Counter
0x1402
Connection Handle
HCI _Read _Link _Quality
0x1403
Connection Handle
HCI _Read _RSSI
0x1405
Connection Handle
HCI _Read _AFH _Channel _Map
0x1406
Connection Handle
HCI _Read _Clock
0x1407
Which Clock
Connection Handle
Status
Connection handle
Failed Contact Counter
Status
Connection handle
Status
Connection Handle
Link Quality
Status
Connection Handle
RSSI
Status
Connection Handle
AFH Mode
AFH Channel Map
Status
Connection Handle
AFH Mode
AFH Channel Map
Yes
Yes
Yes
Yes
Yes
Yes
TESTING
HCI _Read _Loopback _Mode
0x1801
HCI _Write _Loopback _Mode
HCI _Enable _Device _Under _Test
_Mode
0x1802
0x1803
Loopback Mode
States
Loopback Mode
Yes
States
Yes
States
Yes
g,i
18/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
Ver.0.1
(8/13)
Control name
Electrical characteristics
Notes:
a)
Up to seven connections: a slave of up to two masters, and/or a master of up to seven slave.
Some operations restricted or non-functional in a scatternet.
b) Chip resource limits constrain the rate at which ACL and SCO connections can be made and broken to approximately
20 per 15 seconds. The time limit can be configured.
b)
Up to three SCO links. Each SCO link can be routed over the chip’s PCM interface or over HCI/BCSP.
Preliminary Support for SCO over USB or H4 is in place, but testing has been light.
d)
No HCI SCO Host Controller to Host flow control support.
No HCI SCO Host to Host Controller flow control support.
e)
Limited support for “best effort” and “guaranteed” Qos only.
f)
Initial device name taken from PS Keys, and so is maintained through a reset/reboot.
g)
HCI Reset does not work if the device is in local loopback mode.
h)
Optional Paging schemes are not supported.
i)
Remote ACL loopback sometimes deadlocks when the device’s flow control mechanisms assert to each other.
j)
Bluetooth v1.1 specification command, deprecated in the v1.2 specification,or later; support retained for backwards co
mpatibility.
k)
Bluetooth v1.1 specification command, renamed in the v1.2 specification,or later.
Park Mode ---> Park State
Exit Park Mode ---> Exit Park State
Set Host Controller To Host Flow Control ---> Set Controller To Host Flow Control
Change Local Name ---> Write Local Name
Read SCO Flow Control Enable ---> Read Synchronous Flow Control Enable
Write SCO Flow Control Enable ---> Write Synchronous Flow Control Enable
Get Link Quality ---> Read Link Quality
l)
Command not in the Bluetooth v1.1 specification.
m) Underlying Flow_Specification functionality the same as for QoS_Setup.
n) Command which rewrites FROM in module
p)
CVSD not available with 3EV3 or 3EV5 EDR packets.
q)
HCI Setup Synchronous Connection command does not support HV1,HV2 and HV3 Packet Type. If you want to use those
Packet Types, please use HCI Add SCO connection command.
19/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
Ver.0.1
Control name
Electrical characteristics
(9/13)
HCI EVENT LIST
Event Description
OpCode
Parameters
Status
Inquiry _Complete
0x01
Yes
Inquiry _Result
0x02
Inquiry _Result _with _RSSI
0x22
Status
Num Responses
BD ADDR [I]
Page Scan Repetition Mode [I]
Page Scan Period Mode [I]
Page Scan Mode [I]
Class of Device [I]
Clock Offset [I]
Num Responses
BD ADDR [I]
Page Scan Repetition Mode [I]
Page Scan Period Mode [I]
Page Scan Mode [I]
Class of Device [I]
Clock Offset [I]
RSSI [I]
Notes
Inquiry
Yes
Yes
Connection Management
Connection _Complete
0x03
Connection _Request
0x04
Disconnection _Complete
0x05
Synchronous _Connection _Complete
0x2C
Synchronous _Connection _Changed
0x2D
Status
Connection Handle
BD ADDR
Link Type
Encryption Mode
BD ADDR
Class of Device
Link Type
Status
Connection Handle
Reason
Status
Connection Handle
BD ADDR
Link Type
Transmission Interval
Retransmission Window
Rx Packet Length
Tx Packet Length
Air Mode
Status
Connection Handle
Transmission Interval
Retransmission Window
Rx Packet Length
Tx Packet Length
Yes
Yes
Yes
Yes
Yes
20/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
Ver.0.1
Control name
Electrical characteristics
(10/13)
Authentication / Pairing
Authentication _Complete
0x06
Return _Link _Keys
0x15
PIN _Code _Request
Link _Key _Request
0x16
0x17
Link _Key _Notification
0x18
Status
Connection Handle
Num Keys
BD ADDR [I]
Link Key [I]
BD ADDR
BD ADDR
BD ADDR
Link Key
Yes
Yes
Yes
Yes
Yes
Encryption
Encryption _Change
0x08
Change _Connection _Link _Key _Complete
0x09
Master _Link _Key _Complete
0x0A
Status
Connection Handle
Encryption Enable
Status
Connection Handle
Status
Connection Handle
Key Flag
Yes
Yes
Yes
Remote Information
Remote _Name _Request _Complete
0x07
Read _Remote _Supported _Features _Complete
0x0B
Read _Remote _Version _Information _Complete
0x0C
Read _Remote _Extended _Features _Complete
0x23
Status
BD ADDR
Remote Name
Status
Connection Handle
LMP Features
Status
Connection Handle
LMP Version
Manufacture Name
LMP Subversion
Status
Connection Handle
Page Number
Maximum page number
Extended LMP Features
Yes
Yes
Yes
Yes
21/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
Ver.0.1
Control name
Electrical characteristics
(11/13)
Link Policy
QoS _Setup _Complete
0x0D
Role _Change
0x12
Mode _Change
0x14
Flow _Specification _Complete
0x21
Status
Connection Handle
Flags
Service Type
Token Rate
Peak Bandwidth
Latency
Delay Variation
Status
BD ADDR
New Role
Status
Connection Handle
Current Mode
Interval
Status
Connection Handle
Flags
Flow direction
Service Type
Token Rate
Token Bucket Size
Peak Bandwidth
Access Latency
Yes
Yes
Yes
Yes
b,c
General
Command _Complete
0x0E
Command _Status
0x0F
Hardware _Error
0x10
Number _Of _Completed _Packets
0x13
Data _Buffer _Overflow
0x1A
Max _Slots _Change
0x1B
Read _Clock _Offset _Complete
0x1C
Num HCI Command Packets
Command Opcode
Return Parameters
Status
Num HCI Command Packets
Command Opcode
Hardware Code
Number of Handles
Connection Handle [I]
HC Num HCI Data Packets [I]
Link Type
Connection Handle
LMP Max Slots
Status
Connection Handle
Clock Offset
Yes
Yes
Yes
Yes
No
Yes
Yes
Host Controller & Baseband
Flush _Occurred
0x11
Connection Handle
Yes
Loopback _Command
0x19
Yes
Connection _Packet _Type _Change
0x1D
QoS _Violation
0x1E
Page _Scan _Mode _Change
0x1F
Page _Scan _Repetition _Mode _Change
0x20
HCI Command Packet
Status
Connection Handle
Packet Type
Connection Handle
BD ADDR
Page Scan Mode
BD ADDR
Page Scan Repetition Mode
Yes
No
No
Yes
22/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
Ver.0.1
(12/13)
Control name
Electrical characteristics
Notes:
a) Significance and expected recovery procedure is ill defined.
b) Event not in the Bluetooth v1.1 specification.
c) Event provoked by local Flow Specification command, even through the command is not implemented.
d) Optional paging schemes not supported. Bluetooth v1.1 specification only.
23/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-C071063
Ver.0.1
(13/13)
Control name
Electrical characteristics
Module Stack
USB I/F
HOST
USB HCI Host Transport
HCI Implementation
Link Manager
Link Controller
Base Band
Radio
Note:
The protocol stack in the module is compliant with the Specification of the Bluetooth® System V2.0+EDR
Bluetooth® Module
24/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-D071063
(1/10)
Control name
Electrical characteristics
PICS for Firmware Version 21d (Build3059)
The Bluetooth® functions of this module are as below. Depending on firmware version upgrade, the Bluetooth®
functions are subject to change without notice.
SUMMARY
Table 2-1: Controller Core Specification
Item
Specification Name
Core Spec Version 1.1, Adopted 5 Feb 2001 (Ver. 1.1)
Core Spec Version 1.2, Adopted 5 Nov 2003 (Ver. 1.2)
Core Spec Version 2.0, Adopted 4 Nov 2004 (Ver. 2.0)
Core Spec Version 2.0 + EDR, Adopted 4 Nov 2004(Ver. 2.0 + EDR)
Support
No
No
No
Yes
Table 2-2: EDR Features
Prerequisite: 2-1/4 (Ver. 2.0 + EDR)
Item
Feature
EDR for asynchronous transports (single slot)
EDR for asynchronous transports (multi-slot)
EDR for synchronous transports
Support
Yes
Yes
Yes
RF
RF Capabilities (based on PICS proforma for Radio):
Table A.1: RF Capabilities
Item
Capability
Status
Support
Power Class (1,2 or 3)
Power Control
1-slot packets supported
3-slot packets supported
5-slot packets supported
79 Channels
Support for GFSK modulation
Support for π/4-DQPSK modulation
Support for 8DPSK modulation
C.1
C.2
C.3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Allowed
1 .. 3
Values
Supported
C.1: Mandatory to support if Power Class 1 is supported, optional to support if Power Class 2 or 3 is supported.
C.2: Mandatory if SUMMARY, 2-1/4 is claimed; Optional if SUMMARY, 2-1/3 is claimed; Excluded otherwise.
C.3: Mandatory if SUMMARY, 2-1/4 is claimed; Else Optional if (RF, 1/8 AND SUMMARY, 2-1/3) is claimed;
Excluded otherwise.
25/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-D071063
Ver.0.1
(2/10)
Control name
Electrical characteristics
Baseband
Baseband Capabilities (based on PICS proforma for Baseband)
Table B.1: Physical Channel
Item
Capability
Support frequency band and 79 RF channels
Adaptive Frequency Hopping Kernel
Item
Capability
Basic Data Rate, 1 Mbps payload data rate
Enhanced Data Rate, 2 Mbps payload data rate
Enhanced Data Rate, 3 Mbps payload data rate
Status
Support
Yes
Yes
Status
C.1
C.2
Support
Yes
Yes
Yes
Table B.1a: Modulation schemes
C.1: Mandatory if (SUMMARY, 2-1/4) is claimed; Optional if (SUMMARY, 2-1/3) is claimed; Excluded otherwise.
C.2: Mandatory if (SUMMARY, 2-1/4) is claimed; Optional if (BB, 1a/2 AND SUMMARY, 2-1/3) is claimed;
Excluded otherwise.
Table B.2: Link Types
Item
Capability
Support of ACL link
Support of SCO link
Support of eSCO link
Support of Enhanced Data Rate ACL links
Support of Enhanced Data Rate eSCO links
Status
C.1
C.2
Support
Yes
Yes
Yes
Yes
Yes
C.1: Mandatory IF (SUMMARY, 2-2/1 OR SUMMARY, 2-2/2) is claimed;
ELSE Optional IF (SUMMARY, 2-1/3 OR SUMMARY, 2-1/4) is claimed; Excluded otherwise.
C.2: Mandatory IF SUMMARY, 2-2/3 is claimed; ELSE Optional IF (SUMMARY, 2-1/3 OR SUMMARY, 2-1/4) is claimed;
Excluded otherwise.
Table B.3: SCO Link Support
Prerequisite: B.2/2 (Support of SCO link)
Item
Capability
Status
Support
SCO links to same Slave
SCO links to different Slaves
SCO links from same Master
SCO links from different Masters
C.1
C.1
Yes
Yes
Yes
No
Allowed
1 .. 3
1 .. 3
1.. 3
Values
Supported
Allowed
(1 .. 6)
(2 .. 5)
(1 .. 6)
(2 .. )
Values
Supported
C.1: Mandatory to support at least 1 link.
Prerequisite: B.2/3 (Support of eSCO link)
Item
Capability
Status
Support
eSCO links to same Slave
eSCO links to different Slaves
eSCO links from same Master
eSCO links from different Masters
C.2
C.2
Yes
Yes
Yes
No
C.2: Mandatory to support at least 1 link.
26/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-D071063
Ver.0.1
(3/10)
Control name
Electrical characteristics
Table B.4: Common Packet Types
Item
Capability
Support of ID packet type
Support of NULL packet type
Support of POLL packet type
Support of FHS packet type
Support of DM1 packet type
Item
Capability
Support of DH1 packet type
Support of DM3 packet type
Support of DH3 packet type
Support of DM5 packet type
Support of DH5 packet type
Support of AUX1 packet type
Status
Support
Yes
Yes
Yes
Yes
Yes
Status
Support
Yes
Yes
Yes
Yes
Yes
Yes
Table B.5: ACL Packet Types
Table B.5a: Enhanced Data Rate ACL packet types
Prerequisite: B.2/4 (Support of Enhanced Data Rate ACL links)
Item
Capability
Support 2-DH1 packet type
Support 2-DH3 packet type
Support 2-DH5 packet type
Support 3-DH1 packet type
Support 3-DH3 packet type
Support 3-DH5 packet type
Status
C.1
C.2
C.2
C.3
C.4
C.5
Support
Yes
Yes
Yes
Yes
Yes
Yes
C.1: Mandatory IF (SUMMARY, 2-2/1 OR SUMMARY, 2-2/2) is claimed; ELSE Optional IF BB, 1a/2 is claimed;
Excluded otherwise.
C.2: Mandatory IF SUMMARY, 2-2/2 is claimed; ELSE Optional IF BB, 1a/2 is claimed; Excluded otherwise.
C.3: Mandatory IF (SUMMARY, 2-2/1 OR SUMMARY, 2-2/2) is claimed; ELSE Optional IF BB 1a/3 is claimed;
Excluded otherwise.
C.4: Mandatory IF SUMMARY, 2-2/2 is claimed; ELSE Optional IF (BB, 5a/2 AND BB, 5a/4) is claimed;
Excluded otherwise.
C.5: Mandatory IF SUMMARY 2-2/2 is claimed; ELSE Optional IF (BB, 5a/3 AND BB, 5a/4) is claimed; Excluded otherwise.
Table B.6: SCO and eSCO Packet Types
Prerequisite for items 1-4: B.2/2 (Support of SCO link)
Item
Capability
Support of HV1 packet type
Support of HV2 packet type
Support of HV3 packet type
Support of DV packet type
Status
Support
Yes
Yes
Yes
Yes
Status
Support
Yes
Yes
Yes
Prerequisite for items 5-7: B.2/3 (Support of eSCO link)
Item
Capability
Support of EV3 packet type
Support of EV4 packet type
Support of EV5 packet type
27/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-D071063
(4/10)
Control name
Electrical characteristics
Table B.6a: Enhanced Data Rate eSCO packet types
Prerequisite: B.2/5 (Support of Enhanced Data Rate eSCO links)
Item
Capability
Support 2-EV3 packet type
Support 2-EV5 packet type
Support 3-EV3 packet type
Support 3-EV5 packet type
Status
C.1
C.2
C.3
C.4
Support
Yes
Yes
Yes
Yes
C.1: Mandatory IF SUMMARY, 2-2/3 is claimed; ELSE Optional IF BB, 1a/2 is claimed; Excluded otherwise.
C.2:Optional IF BB, 1a/2 is claimed; Excluded otherwise.
C.3: Mandatory IF SUMMARY, 2-2/3 is claimed; ELSE Optional IF BB, 1a/3 is claimed; Excluded otherwise.
C.4: Optional IF BB, 1a/3 is claimed; Excluded otherwise.
Table B.7: Page Procedures
Item
Capability
Support paging
Support page scan
Status
Support
Yes
Yes
Supports Interlaced Scan during page scan
Yes
Item
Capability
Supports mandatory scan mode)
Status
Support
Yes
Item
Capability
Supports paging mode R0
Supports paging mode R1
Supports paging mode R2
Status
C.1
C.1
C.1
Support
Yes
Yes
Yes
Status
Support
Yes
Yes
Yes
Capability
Support inquiry
Inquiry scan with first FHS
Status
Support
Yes
Yes
Supports the dedicated inquiry access code
Supports Interlaced Scan during inquiry scan
Yes
Yes
Table B.8: Paging Schemes
Table B.9: Paging Modes
C.1: At least one of the paging scan modes must be supported.
Table B.9 (b): Paging Train Repetition
Item
Capability
Supports Npage >= 1
Supports Npage >= 128
Supports Npage >= 256
Note: The master should use Npage >= 256 unless it knows what SR mode the slave uses.
Table B.10: Inquiry Procedures
Item
28/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-D071063
(5/10)
Control name
Electrical characteristics
Table B.11: Piconet Capabilities
Item
Capability
Status
Support
Broadcast messages
Point-to-multipoint connections
Yes
Yes
Allowed
N/A
(2 .. 7)
Values
Supported
Table B.12: Scatternet Capabilities
Item
Capability
Act as Master in one piconet and as Slave in another piconet
Act as Slave in more than one piconet
Status
Support
Yes
Yes
Table B.13: Synchronous Coding Schemes
Prerequisite: B.2/2 (SCO link Support)
Item
Capability
A-law
u-law
CVSD
Transparent Synchronous Data
Status
Support
Yes
Yes
Yes
Yes
Status
Support
Yes
Yes
Status
Support
Yes
Yes
Link Manager
Link Manager Capabilities (based on PICS proforma for Link Manager)
Table C.1: Response Messages
Item
Capability
Accept message
Reject message
Item
Capability
3-slot packets
5-slot packets
Table C.2: Supported Features
Encryption
Yes
10
11
12
13
14
15
16
17
18
Slot offset
Timing accuracy
Role switch (Master/Slave)
Hold mode
Sniff mode
Park mode
Power Control
Channel quality driven data rate
SCO link
RSSI
Broadcast encryption
eSCO link
Adaptive frequency hopping
Enhanced Data Rate ACL
Enhanced Data Rate eSCO
C.1
C.2
C.3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
C.1: If Power Class 1 is supported (RF, 1/1=1) then Mandatory, else Optional.
C.2: Mandatory IF (SUMMARY 2-2/1 OR SUMMARY 2-2/2) is claimed;
ELSE Optional IF (SUMMARY 2-1/3 OR SUMMARY 2-1/4) is claimed; Excluded otherwise.
C.3: Mandatory IF SUMMARY 2-2/3 is claimed; ELSE Optional IF (SUMMARY 2-1/3 OR SUMMARY 2-1/4) is claimed; Excluded
otherwise.
29/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-D071063
Control name
Electrical characteristics
(6/10)
Table C.3: Authentication
Item
Capability
Initiate authentication before connection completed
Initiate authentication after connection completed
Respond to authentication request
Status
Support
Yes
Yes
Yes
Item
Capability
Initiate pairing before connection completed
Initiate pairing after connection completed
Respond to pairing request
Use fixed PIN and request
responder to initiator switch
Use variable PIN
Accept initiator to responder switch
Status
Support
Yes
Yes
Yes
C.1
Yes
C.1
C.2
Yes
Yes
Capability
Creation of link key - Unit Key
Creation of link key - Combination Key
Initiate change of link key
Accept change of link key
Status
C.1
C.1
Support
Yes
Yes
Yes
Yes
Accept pairing with Unit Key
Yes
Table C.4: Pairing
C.1: Mandatory to support at least one of Pairing /4 and Pairing /5.
C.2: Mandatory to support if Pairing /5 AND (Pairing /1 OR Pairing /2) is supported.
Table C.5: Link Keys
Item
C.1: Mandatory to support at least one of the key types.
Table C.6: Encryption
Prerequisite: C.2/3 (Encryption supported)
Item
Capability
Initiate encryption
Accept encryption requests
Status
Support
Yes
Yes
Key size negotiation
Start encryption
Accept start of encryption
Stop encryption
Accept stop of encryption
Yes
Yes
Yes
Yes
Yes
Item
Capability
Request clock offset information
Respond to clock offset requests
Status
Support
Yes
Yes
Table C.7: Clock Offset Information
30/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-D071063
(7/10)
Control name
Electrical characteristics
Table C.8: Slot Offset Information
Prerequisite: C.2/4 (Slot offset)
Item
Capability
Send slot offset information
Status
C.1
Support
Yes
C.1: Mandatory to support if support if Role Switch/1 (Master/Slave switch) otherwise optional.
Table C.9: Timing Accuracy Information
Prerequisite: C.2/5 (Timing accuracy)
Item
Capability
Request timing accuracy information
Respond to timing accuracy information requests
Item
Capability
Request LM version information
Respond to LM version information requests
Item
Capability
Request supported features
Respond to supported features requests
Request extended features mask
Respond to extended features Request
Status
Support
Yes
Yes
Status
Support
Yes
Yes
Status
C.1
C.2
C.2
Support
Yes
Yes
Yes
Yes
Table C.10: LM Version Information
Table C.11: Feature Support
C.1: Mandatory to support if any of the optional features in Supported Features /1-3, Supported Features /5,
Supported Features /7-12, Supported Features /14-16, Adaptive Frequency Hopping /1 is requested
by the IUT otherwise optional.
C.2: Mandatory if a feature requiring another features page is supported, otherwise optional.
Table C.12: Name Information
Item
Capability
Request name information
Respond to name requests
Status
Support
Yes
Yes
Status
Support
Yes
Yes
Status
Support
Yes
Table C.13: Role Switch
Prerequisite: C.2/6 (Role switch)
Item
Capability
Request Master Slave switch
Accept Master Slave switch requests
Item
Capability
Detach connection
Table C.14: Detach
31/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-D071063
Ver.0.1
(8/10)
Control name
Electrical characteristics
Table C.14a: Setting up and Removing Enhanced Data Rate ACL Connection
Item
Capability
Enter Enhanced Data Rate
Exit Enhanced Data Rate
Status
C.1
C.1
Support
Yes
Yes
C.1: Mandatory if LMP, 2/17 supported, otherwise excluded.
Table C.14b: Setting up and Removing Enhanced Data Rate eSCO Connection
Item
Capability
Enter and exit eSCO using Enhanced Data
Rate Packets
Status
Support
C.1
Yes
Status
C.1
Support
Yes
Yes
Yes
Yes
Capability
Status
Support
Request sniff mode
Respond to sniff mode requests (renegotiate or reject)
Yes
Yes
Request un-sniff
Accept un-sniff requests
C.1
Yes
Yes
C.1: Mandatory if LMP, 2/18 supported, otherwise excluded.
Table C.15: Hold mode
Prerequisite: 2/7 (Hold mode)
Item
Capability
Force hold mode
Request hold mode
Respond to hold mode requests
Accept forced hold mode
C.1: Mandatory to support if LMP, 15 /1 (Force hold mode) is supported, otherwise optional.
Table C.16: Sniff mode
Prerequisite: C.2/8 (Sniff mode)
Item
C.1: If LMP, 16/2 (Request sniff mode) is supported then mandatory to support, otherwise optional.
Table C.17: Park mode
Prerequisite: C.2/9 (Park Mode)
Item
10
11
12
13
Capability
Status
Support
Request park mode
Respond to park mode requests
Yes
Yes
Set up broadcast scan window
Accept changes to the broadcast scan window
Modify beacon parameters
Accept modification of beacon parameters
Request Unpark using PM_ADDR
Request Unpark using BD_ADDR
Slave requested Unpark
Accept Unpark using PM_ADDR
Accept Unpark using BD_ADDR
C.1
C.1
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
C.1: If LMP, 17/3 (Respond to park mode requests) is supported then at least one of LMP, 17 /9
(Unpark using PM_ADDR) or LMP, 17/10 (Unpark using BD_ADDR) is mandatory to support, otherwise optional.
32/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-D071063
(9/10)
Control name
Electrical characteristics
Table C.18: Power Control
Prerequisite: C.2/13 (RSSI)
Item
Capability
Request to increase power
Request to decrease power
Status
Support
Yes
Yes
Status
Support
Yes
Yes
Status
Support
Yes
Yes
Status
C.1
Support
Yes
Yes
Yes
Prerequisite: C.2/10 (Power control)
Item
Capability
Respond when max power reached
Respond when min power reached
Item
Capability
Set link supervision timeout value
Accept link supervision timeout setting
Item
Capability
Channel quality driven change between DM and DH packet types
Force/Request change of Quality of Service
Request change of Quality of Service
Table C.19: Link supervision Timeout
Table C.20: Quality of Service
C.1: Mandatory to support if support of LMP, 2 /11 is stated in the feature request, otherwise optional.
Table C.21: SCO Links
Prerequisite: C.2/12 (SCO link)
Item
Capability
Initiate SCO links, as Master
Initiate SCO links, as Slave
Accept SCO links
Remove SCO link, as Master
Remove SCO link, as Slave
Negotiate SCO link parameters, as Master
Negotiate SCO link parameters, as Slave
Status
C.1
C.2
C.3
C.4
Support
Yes
Yes
Yes
Yes
Yes
Yes
Yes
C.1: Mandatory to support if LMP, 21 /1 (Initiating SCO links, as Master) is supported, otherwise optional.
C.2: Mandatory to support if LMP, 21 /2 (Initiating SCO links, as Slave) is supported, otherwise optional.
C.3: Mandatory to support if LMP, 21 /1 (Initiating SCO links, as Master) or LMP, 21/3 (Accept SCO links) is supported, otherwise
optional.
C.4: Mandatory to support if LMP, 21 /2 (Initiating SCO links, as Slave) or LMP, 21/3 (Accept SCO links) is supported, otherwise
optional.Comments:
Table C.22: Multi-Slot Packages
Item
Capability
Accept maximum allowed number of slots to be used
Request maximum number of slots to be used
Accept request of maximum number of slots to be used
Status
C.1
C.1
C.1
Support
Yes
Yes
Yes
C.1: Mandatory to support if LMP, 2 /1 and/or LMP, 2 /2 is supported in the feature request, otherwise optional.
33/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AE-D071063
(10/10)
Control name
Electrical characteristics
Table C.23: Paging Scheme
Item
Capability
Request page mode to use
Accept suggested page mode
Request page scan mode to use
Accept suggested page scan mode
Item
Capability
Create connection for higher layers
Respond to requests to establish connections for higher layers
Indicate that link set-up is completed
Item
Capability
Activate test mode
Ability to reject activation of test mode if test mode is disabled
Control test mode
Ability to reject test mode control commands if test mode is disabled.
Status
Support
Yes
Yes
Yes
Yes
Status
Support
Yes
Yes
Yes
Status
Support
Yes
Yes
Yes
Yes
Table C.24: Connection Establishment
Table C.25: Test Mode
Table C.26: Adaptive Frequency Hopping
Prerequisite: C.2/20 (AFH)
Item
Capability
Support of AFH switch as master
Support of AFH switch as slave
Support of Channel Classification reporting as master
Support of Channel Classification reporting as slave
Support channel classification from host
Support of Channel Classification
Status
C.1
C.2
C.3
Support
Yes
Yes
Yes
Yes
Yes
Yes
C.1: Optional if LMP, 26/6 is supported, otherwise excluded.
C.2: Mandatory if LMP, 26/6 is supported, otherwise excluded.
C.3: Mandatory if LMP, 26/1 or LMP, 26/4 is supported, otherwise optional.
Notes:
This Data Report is based on “1846_BC4-Ext_RF.ICS-2.0.E.0”, “1847_HCIStack2.0EDR_BB.ICS-2.0.E.0”,
“1848_HCIStack2.0EDR_LMP.ICS-2.0.E.0”and “SUM.ICS-2.0.E.4”.
34/40
TAIYO YUDEN
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-MC-A071063
Control name
Circuit Schematic
(1/1)
Block Diagram
CRYSTAL
26 MHz
32Kbit
EEPROM
Antenna
Baseband
Balun
filter
Connector
RF
Bluetooth
Device
Micro
controller
LDO
GND
USB_DETACH
/RESET
USB DUSB D+
VDD
35/40
TAIYO YUDEN
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AD-A071063
Ver.0.1
(1/1)
Control name
Outline/Appearance
Unit: mm, Tolerances unless otherwise specified: +/-0.2mm
Note:
Outline/Appearance data is PRELIMINARY, not guaranteed and subject to change without notice.
Please contact Taiyo Yuden for the details of module mountings.
TAIYO YUDEN
36/40
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-AD-B071063
Control name
Outline/Appearance
(1/1)
Indication label
Label1
Case-side
(ケース側 1 枚目)
Product Number:EYSMJCS
2.4FH1
EYSMJCSFX
201 WW 07215204 CA46920-0316 01A
Taiyo Yuden Co.,Ltd.
Label2
Case-side
ABCDEFGHIJK
(ケース側 2 枚目)
IC: 4389B-EYSMJCS
FCC ID:RYYEYSMJCS
Label3
Back-side
XXX-XXXXXXX
(基板側)
LOT.No
00037AAAAAAA
Material: PET ( UL969 ) / Label color : White
TAIYO YUDEN
37/40
24-Aug.-2007
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Control No.
HD-BA-A071063
Ver.0.1
(1/1)
Control name
Pin Layout
Pin Descriptions
Terminal
No.
Terminal name
Input/Output
Description
GND
PIO2/USB_DETACH
Input
/RESET
Input
USB_D-
Input/Output
USB data (Negative) input-output
USB_D+
Input/Output
USB data (Positive) input-output
VDD
Input
Remark
Ground
DETACH signal input
Low
USB connect
High
USB disconnect
Active low RESET signal with internal weak
pull-up
DC3.3V Power supply
Note 1
Note 2
Note 3
Notes:
1. Strength pull-downs (pull-ups) are equivalent to a few kOhms resistance, but are more accurately modeled as
a 40uA current drain (source).
2. Weak pull-ups can be thought of 1M Ohm connections to VDD, but are more accurately modeled as a -1uA
current source.
3. Pin 6 (VDD) is used for power supply of BT module. To fill the standard of “Supply voltage ripple and spike
noise”, the capacitor, which has the capacity of 2.2uF or more, should be put in the terminal VDD outside as
a bypass capacitor.
TAIYO YUDEN
38/40
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
FCC Regulatory Information
CAUTION: To maintain compliance with FCC’s RF exposure guidelines, use only the supplied antenna.
Unauthorized antenna, modification, or attachments could damage the transmitter and may violate FCC
regulations.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may Cause undesired
operation.
Canada Regulatory Information
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of
the device.
L'utilisation de ce dispositif est autorisée seulement aux conditions suivantes :
(1) il ne doit pas produire de brouillage et
(2) l'utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce
brouillage est susceptible de compromettre le fonctionnement du dispositif.
R&TTE Directive Information
Hereby Taiyo Yuden Co., Ltd., declares that this Complete Class2 Bluetooth Module (Model No.:
EYSMJCS) is in compliance with the essential requirements and other relevant provisions of Directive
1999/5/EC
Caution
Please note that this users manual should not be provided to end-users.
TAIYO YUDEN
39/40
24-Aug.-2007
Ver.0.1
TAIYO YUDEN Confidential
& Tentative
EYSMJCS
Notice
At the use of our Module, following is required to be shown under the responsibility of the
manufacture who integrates it into their device.
The following sentence has to be displayed on the outside of the device in which the module is installed:
"Contains Transmitter Module FCC ID: RYYEYSMJCS ", or "Contains IC: 4389B-EYSMJCS "
FCC Regulatory information
CAUTION: To maintain compliance with FCC’s RF exposure guidelines, use only the supplied antenna.
Unauthorized antenna, modification, or attachments could damage the transmitter and may violate FCC
regulations.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may Cause undesired
operation.
Canada Regulatory information
Operation is subject to the following two conditions:
(3) this device may not cause interference, and
(4) this device must accept any interference, including interference that may cause undesired operation of
the device.
L'utilisation de ce dispositif est autorisée seulement aux conditions suivantes :
(3) il ne doit pas produire de brouillage et
l'utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage
est susceptible de compromettre le fonctionnement du dispositif.
R&TTE Directive information
Hereby [Name of manufacture(*)], declares that this [type of equipment(*)] is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC
(*) Note: Please write in your company name and type of equipment into [ ].
TAIYO YUDEN
40/40

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Warning                         : Error loading Encrypt object
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RYYEYSMJCS

Navigation menu