Tagsys CONVYRANT Conveyor Antenna User Manual ConveyAntInstall270
Tagsys S.A. Conveyor Antenna ConveyAntInstall270
Tagsys >
Contents
- 1. Installation
- 2. Installation Guide
Installation Guide
Conveyor Antenna for 270 TL Installation Guide Revision 1.0 TAGSYS April 2004 Conveyor Antenna for 270 TL Installation Guide Publishing Information Disclaimer and Limitation of Liability All information herein is either public information or is the property of and owned solely by TAGSYS who shall have and keep the sole right to file patent applications or any other kind of intellectual property protection in connection with such information. Nothing herein shall be construed as implying or granting to you any rights, by license, grant or otherwise, under any intellectual and/or industrial property rights of or concerning any of TAGSYS’ information. This document can be used for informational, non-commercial, internal and personal use only provided that: § the copyright notice below, the confidentiality and proprietary legend and this full warning notice appear in all copies. § this document shall not be posted on any network computer or broadcast in any media and no modification of any part of this document shall be made. Use for any other purpose is expressly prohibited and may result in severe civil and criminal liabilities. The information contained in this document is provided “AS IS” without any warranty of any kind. Unless otherwise expressly agreed in writing, TAGSYS makes no warranty as to the value or accuracy of information contained herein. The document could include technical inaccuracies or typographical errors. Changes are periodically added to the information herein. Furthermore, TAGSYS reserves the right to make any change or improvement in the specifications data, information, and the like described herein, at any time. Therefore TAGSYS assumes no liability and is not responsible for customer applications or product or software that include TAGSYS products. TAGSYS HEREBY DISCLAIMS ALL WARRANTIES AND CONDITIONS WITH REGARD TO THE INFORMATION CONTAINED HEREIN, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE AND NON-INFRINGEMENT. IN NO EVENT SHALL TAGSYS BE LIABLE, WHETHER IN CONTRACT, TORT OR OTHERWISE, FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DAMAGES RESULTING FROM LOSS OF USE, DATA, PROFITS, REVENUES, OR CUSTOMERS, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF INFORMATION CONTAINED IN THIS DOCUMENT. TAGSYS does not and shall not warrant that this product/system/equipment will be resistant to all possible attacks, and shall not incur, and disclaims, any liability in this respect. Even if each product is compliant with current security standards in force on the date of their design, security mechanisms' resistance necessarily evolves according to the state-of-the-art in security and notably under the emergence of new attacks. Under no circumstances shall TAGSYS be held liable for any third party actions, and in particular in case of any successful attack against systems or equipment incorporating TAGSYS products. TAGSYS disclaims any liability with respect to security for direct, indirect, incidental or consequential damages that result from any use of its products. It is further stressed that independent testing and verification by the person using the product is particularly encouraged, especially in any application in which defective, incorrect, or insecure functioning could result in damage to persons or property, denial of service, or loss of privacy. © 2000-2004 TAGSYS. All rights reserved. Microsoft, Visual C++, Windows, and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the U.S.A. and/or other countries. Printed in France. TAGSYS – 180 Chemin de St Lambert, 13821 LA PENNE SUR HUVEAUNE, France. Tel: +33 (0)4.91.27.57.00 / Fax: +33 (0)4.91.27.57.01 Document Reference: 10926A1 2/26 Revision 1.0 September 20034 Read This First Read This First Welcome to the TAGSYS RFID System. This Installation Guide is designed to help you get up and running quickly using this high-quality Radio Frequency Identification (RFID) system. It describes all you need to know about how to install and use the TAGSYS system and its associated applications. It provides a step-by-step guide for the following procedures: § Installation of the Conveyor Antenna § Configuring the product for use within your library system § Using the product with your computer system This guide is designed for all TAGSYS partners and for TAGSYS Expert Network customers implementing a low-cost and high-performance RFID solution. This document does not assume any previous knowledge of Radio Frequency Identification (RFID) technology. Conventions Symbol Meaning CAUTION: A note that advises users that a specific action could result in the loss of data or damage the hardware. WARNING: A note that advises users that a specific action may result in physical harm. A note that provides additional information that helps the user perform a task or obtain the best performance from the product. Abbreviations and Acronyms AFI Application Family Identifier AON All Or None API Application Programming Interface RF Radio Frequency Glossary Anti-Collision Tag capability making it readable while other tags are present in the RF field. Antenna An aerial that receives and/or transmits radio frequency signals. Aerials are manufactured in a variety of forms, shapes and sizes. BNC Connector Cylindrical metal connector with a copper core that is located at the tip of a coaxial cable, and is used to connect cables together. It attaches by pushing and twisting the outer cylinder on to two locking pins. Coupler See Reader. April 2004 Revision 1.0 3/26 Conveyor Antenna for 270 TL Installation Guide IEC Connector Three-pin connector used on sockets that carry mains electricity to the computer. All PCs use a male IEC connector and mains lead with a female IEC connector. Multi-Read See Anti-Collision Packaged Reader A reader in its casing. Phase Shift Difference of phase between the 13.56 MHz field emitted by two antennas. This feature is dedicated to rotating field applications and three-dimensional volume smart label detection. Protocol A set of rules governing a particular function, such as the flow of data/information in a communication system (communication between a smart label and a reader or a reader and a PC or host computer). Radio Frequency Identification System (RFID) An automatic identification and data capture system comprising one or more readers and one or more smart labels in which data transfer is achieved by means of suitable modulated inductive or radiating electromagnetic carriers. Reader Electronic system for the communication between smart labels and host computers. Reader Talks First Chip protocol for exchanges between the reader and the chip, whereby the chip waits for a command from the reader to which it responds. RS-232 Electronic Industries Association (EIA) standard for serial interfaces between computers and peripherals that defines the function, the electrical characteristics and the timing of signals. RS-485 Electronic Industries Association (EIA) standard for multipoint, differential data transmission. It allows multiple nodes to communicate bi-directionally over 1 or 2 twisted pairs. Smart Label Small, flexible tag from the 13.56 MHz TAGSYS product line. A smart label is made of a chip connected to an etched antenna. Tag See Smart Label. Tag Talks First Chip protocol for exchanges between the reader and the chip, whereby the tag sends information continuously, without waiting for a specific command from the reader. Transceiver A combined transmitter and receiver. Transponder A combined receiver/transmitter that automatically transmits a signal when a ‘trigger’ is received by it. The trigger is often a pulse, called an interrogation pulse. 4/26 Revision 1.0 September 20034 Read This First If you need assistance Please contact your nearest TAGSYS sales representative or the TAGSYS welcome desk at: Telephone: Fax: E-Mail: +33 (0) 4 91 27 57 00 +33 (0) 4 91 27 57 01 info@tagsys.net Contact for Comments We welcome your feedback to help us provide high quality documentation. For technical comments, please contact our welcome desk: Telephone: Fax: E-Mail: +33 (0) 4 91 27 57 00 +33 (0) 4 91 27 57 01 info@tagsys.net Please remember to quote the Document Reference Number 10926A1, your job title and your company. Quality Issues TAGSYS implements stringent quality controls at all stages of its manufacturing process. However, should you find a defect with this product, please notify your TagSys Quality Service representative using the dedicated Product Return Form. Telephone: Fax: April 2004 +33 (0) 4 91 27 57 36 +33 (0) 4 91 27 57 02 Revision 1.0 5/26 Conveyor Antenna for 270 TL Installation Guide Table of Contents Publishing Information Disclaimer and Limitation of Liability Read This First Conventions Abbreviations and Acronyms Glossary If you need assistance Contact for Comments Quality Issues For Your Safety 1.1 1.2 1.3 General Use Care and Maintenance Important Safety Information 1.3.1 1.3.2 2.1 2.2 Occupational Health and Safety Notices Regulatory Notices 10 11 12 3.1 12 Delivery Kit Installation 14 4.1 4.2 4.3 14 15 16 Antenna Location Antennas Active Area Installing the Conveyor Antenna 4.3.1 In Europe (CE and RTTE Directives) In USA (FCC Directive) In Canada Overview 4.4 4.5 4.6 4.7 Operating Environment Medical Devices Certification 2.2.1 2.2.2 2.2.3 Guides 17 Installing the TR-L100 Reader Unit Installing the Signal/Buzzer Box Cabling Requirements Installation Test 18 18 19 19 Maintenance 20 5.1 5.2 5.3 20 20 20 Servicing the Conveyor Antenna Servicing the Reader Unit Servicing the Signal Box Technical Data 21 6.1 6.2 21 22 Mechanical Characteristics Electrical Characteristics Warranty Conditions 23 7.1 Warranty 23 7.1.1 7.1.2 7.1.3 23 24 24 6/26 Warranty Exclusions General Provisions How to Return Defective Products Revision 1.0 September 20034 For Your Safety 1 For Your Safety 1.1 General Use The Conveyor Antenna is designed to be rugged and reliable and to provide years of trouble-free service. Please observe the following general tips: § Take care not to scratch the device. Keep the device clean. When working with the device, use only TAGSYS-approved accessories. § This device is not waterproof and should not be exposed to rain or moisture. Under extreme conditions, water may enter the circuitry. § Take care not to drop the device or subject it to any strong impact. § Protect the device from extreme temperatures. For example, keep it away from heaters and other heat sources. § Do not store or use the device in any location that is extremely dusty, damp, or wet. § Use a soft, damp cloth to clean the device. If the surface of the device becomes soiled, clean it with a soft cloth moistened with a diluted window-cleaning solution. 1.2 Care and Maintenance This device is a product of superior design and should be handled with care. The suggestions below will further increase the lifetime of this device. § Keep the device and all parts and accessories out of the reach of small children. § Keep the device dry. Precipitation, humidity and liquids contain minerals that will corrode electronic circuits. § Do not use or store the device in dusty, dirty areas. Its moving parts can be damaged. § Do not store in hot areas. High temperatures can shorten the life of electronic devices and warp or melt certain plastics. § Do not store in cold areas. When the device warms up (to its normal temperature), moisture can form inside the device, which may damage electronic circuit boards. § Do not attempt to open the device. Non-professional handling of the device may damage it. § Handle the device with care. Shocks may break internal circuit boards. § Do not clean the device with harsh chemicals, cleaning solvents or strong detergents. Gently wipe the device with a soft cloth slightly dampened in a mild soap-and-water solution. § Do not paint the device. Paint may clog the device’s moving parts and prevent proper operation. April 2004 Revision 1.0 7/26 Conveyor Antenna for 270 TL Installation Guide 1.3 Important Safety Information 1.3.1 Operating Environment Follow all special regulations that are applicable in any area and always switch off the device whenever its use is prohibited, or when it may cause interference or danger. When connecting the device or any accessory to another device, read its user’s guide for detailed safety instructions. Do not connect incompatible products. As with all RF equipment, users are advised that the equipment should only be used in its normal operating position. 1.3.2 Medical Devices Most modern electronic equipment is shielded from radio-frequency (RF) signals. However, other electronic equipment may not be shielded against the RF signals from your device. Operation of radio transmitting equipment, including cellular mobile phones, may interfere with the functionality of inadequately protected medical devices. Consult a physician or the manufacturer of the medical device to determine if they are adequately shielded from external RF energy or if you have any questions. 8/26 Revision 1.0 September 20034 Certification 2 Certification 2.1 Occupational Health and Safety Notices TAGSYS Products have been designed not to exceed the limits given in the European Standard EN 50364 “Limitation of human exposure to electromagnetic fields from devices used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications” in conjunction with the European Standard EN 50357 describing how to evaluate the exposure level. It is the responsibility of the TAGSYS Partner to install the Conveyor Antenna as described in TAGSYS Product Manuals or TAGSYS Documentation and with the appropriate antennas. Modification of any TAGSYS System is prohibited without the written consent of TAGSYS. Unauthorized modifications may void the conformity of the equipment to safety norm and will void the TAGSYS warranty. An RF fields survey has been carried out on all the System components, in accordance with AS/NZS 2771.1: Radio Frequency Radiation, Part 1. According to this standard the maximum allowable RF exposure levels (non-occupational) at 3 kHz to 300 GHz are 200 µW/cm2. 2.2 Regulatory Notices An RFID system typically composed of an RF emission device such as the Conveyor Antenna is subject to national regulations that may differ by country. One important item to consider is the maximum permissible magnetic field intensity at a distance of 10 meters from the antenna that must not exceed 42 dBµA/m in Europe and 104 dBµV/m in the US. In compliance with these regulations, only the following two configurations are authorized and will be installed by approved TAGSYS technical representatives: • Config. 1: 300 x 900 mm. antenna coil with 2 Watt Output Power • Config. 2: 200 x 900 mm antenna coil with 2 Watt Output Power The Conveyor Antenna meets these limits. It is the responsibility of the TAGSYS Partner to install the Conveyor Antenna as described in this Installation Guide or in TAGSYS Documentation. The installation of the conveyor antenna configuration and output power settings by unauthorized technical personnel is prohibited. 2.2.1 In Europe (CE and RTTE Directives) The Conveyor Antenna complies (CE Declaration of Conformity granted) with the European EMC directive. The Conveyor Antenna complies with the requirements of the Telecommunication Terminal Equipment Act (FTEG) and the RTTE Directive 1995/5/EC. Any modification of the Conveyor Antenna is prohibited without the written consent of TAGSYS. Unauthorized modifications may void the conformity of the equipment to CE and RTTE Directives and will void the TAGSYS warranty. April 2004 Revision 1.0 9/26 Conveyor Antenna for 270 TL Installation Guide If a Conveyor Antenna is further integrated in a different product, it is the responsibility of the manufacturer of this complementary product to obtain the required approvals for this product. 2.2.2 In USA (FCC Directive) The Conveyor Antenna has been designed to comply with Part 15 of the FCC Rules. Furthermore typical configurations based on a Medio S002 have been successfully tested with Part 15 of the FCC rules (FCC ID Number pending). Conveyor Antenna with Medio L100 Reader Config. 1: 300 x 900 mm antenna coil with 2 Watt Output Power Config. 2: 200 x 900 mm. antenna coil with 2 Watt Output Power WARNING TO USERS IN THE UNITED STATES FEDERAL COMMUNCIATIONS COMMISSION (FCC) RADIO INTERFERENCE STATEMENT 47 CFR Section 15.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different to that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. NO UNAUTHORIZED MODIFICATIONS 47 CFR Section 15.21 CAUTION: This equipment may not be modified, altered, or changed in any way without signed written permission from TAGSYS SA. Unauthorized modification may void the equipment authorization from the FCC and will void the TAGSYS warranty. ANTENNA REQUIREMENT 47 CFR Section 15.203 CAUTION: This equipment must be professionally installed. The installer shall be responsible for ensuring that the proper antenna is employed so that the limits in this part are not exceeded. Nonprofessional installation or installation of the equipment with an improper antenna may void the equipment authorization from the FCC and will void the TAGSYS warranty. Operation is subject to the following two conditions: (1) The system devices may not cause harmful interference, and (2) The library system devices must accept any interference received, including interference that may cause undesired operation. 10/26 Revision 1.0 September 20034 Certification 2.2.3 In Canada Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. April 2004 Revision 1.0 11/26 Conveyor Antenna for 270 TL Installation Guide 3 Overview The Conveyor Antenna (Figure 1) has been optimized for use with the TAGSYS Medio L100 and Medio L200 readers for garment tracking applications. For Textile Rental and Laundry applications, the Conveyor Antenna is recommended for: • On-the-fly garment identification for automatic sorting • Automatic reading at loading points An optional signal box is available that indicates a correct tag reading with a buzzer or a flashing light. Optimal performance is achieved when the tags to be read are presented in parallel to the conveyor antenna and centered on the active area antenna according to the internal antenna configuration. Several antenna configurations are available inside the shape and have to be carefully linked to the tag positioning. To identify the best solution for your system, it is strongly recommended to read the TAGSYS Textile Tag Positioning Guide. Figure 1: Conveyor Antenna 3.1 Delivery Kit The items listed in Table 1 are included in the delivery kit. Table 1: Contents of the Delivery Kit Quantity 12/26 Description Conveyor Antenna with 2 coaxial cables with 6 ferrite beads each TR-L100 Reader Unit Signal Box, including 6-meter shielded UL cable (Optional) Welcome Letter / Product Return Form CD-ROM with: • Conveyor Antenna Installation Guide • Textile Tag Positioning Guide Revision 1.0 September 20034 Overview Figure 2: Full Conveyor Antenna System with the TR-L100 Reader and Signal Box April 2004 Revision 1.0 13/26 Conveyor Antenna for 270 TL Installation Guide 4 Installation Before installing the Conveyor Antenna in your industrial laundry or textile rental conveyor system, it is strongly recommended to read the TAGSYS Textile Tag Positioning Guide that provides information on how to select the best antenna configuration for your conveyor system. Figure 3: Standard Upright Installation 4.1 Antenna Location The antenna is designed for an industrial indoor usage. The recommended position for the Conveyor Antenna is the upright conveyor configuration. Using the guidelines provided in the TAGSYS Textile Tag Positioning Guide, identify the best location of the Conveyor Antenna in relation to the following considerations: • The conveyor drive system • The position of the tags attached to garments and the antenna active area • Garment guide system (either an independent unit or the conveyor antenna panel itself) • L100 Reader cannot be more than 3 meters distant • Possible disturbances (power cables, motors, variable frequency drives, etc.) 1. For optimum performance, always ensure that any metallic or conductive parts are located behind the antenna. 2. Shortening or extending the supplied coaxial antenna cables may decrease performance. 3. Do not place antenna cables close to other cables, especially power cables 14/26 Revision 1.0 September 20034 Installation 4.2 Antennas Active Area IMPORTANT: Note that the dimensions of the antennas inside the conveyor antenna housing given in this document are based on the actual size of the radiating coil and not on the overall size of the individual antenna unit. Several antenna configurations are available and must be carefully linked to the tag positioning. Figure 4 shows the various antenna configurations used with the conveyor antenna and the 270TL tag. It is strongly recommended to read the Textile Tag Positioning Guide to decide which configuration is best adapted to your system. Figure 4: Conveyor Antenna Configurations for 270TL 41cm 41cm 4 cm 30cm 100cm 100cm 90cm 20cm 100cm 90cm TR CA8 TR CA 7 TR CA7 Note that the dimensions of the antennas inside the conveyor antenna housing are based on the actual size of the radiating coil and not on the overall size of the individual antenna unit. The TR-CA7 (300x900) antenna is generally the most popular model for loading or marrying stations as its configuration provides the greatest continuous vertical reading area (almost 1 meter). In this case, garments of any type or size are easily read when they pass in front of this antenna. However, if the garments are presented quickly on the fly on a conveyor in front of the TR-CA7 antenna, some inversion between following garments may occur. In this case, it is best to use the April 2004 Revision 1.0 15/26 Conveyor Antenna for 270 TL Installation Guide TR-CA8 antenna that has a reduced horizontal reading area (200 mm x 900). In that case 2 following tags at the same time in the reading area almost never happen. If a large amount of ambient noise is generated by the conveyor system, it is best to reduce the power of the reader or the size of the top antenna (generally the closest to the noise source). so as not to affect reading performance. In this case, other conveyor antenna configurations may be used (see other TR-Ca for single read tag user’s guide). The reading distances for the various antennas are given in Table 2. Table 2: Antenna Reading Distances Radiating Antenna Coil Dimension 4.3 Average Reading Distance Average Reading Distance (under 2Watts) (under 1Watt) 300 x 900 mm. 150 mm. 110mm 200 x 900 mm. 145 mm. 100mm Installing the Conveyor Antenna The lightweight conveyor antenna can be mounted in any position using brackets. It is recommended to use brackets made of a non-metallic material. If metallic brackets are used, make sure that they do not form a loop that may create interference and reduce antenna performance. Brackets are attached to the Conveyor Antenna at the points shown in Figure 8. M5x14 screws (metric threaded) are included in the delivery kit for attaching the brackets. If mounted as shown in Figure 5, the position of the conveyor antenna can then be finely adjusted in order for the tag positioning area of the garments to coincide with the reading areas of the conveyor antenna. 16/26 Revision 1.0 September 20034 Installation Figure 5: Mounting Brackets on Conveyor Antenna 4.3.1 Guides Guides are often used along the conveyor to protect garments and to ensure that garments are correctly presented in front of the antenna for valid reading of their tags the hangers and to prevent them from swinging. In some cases, items can be correctly positioned by having the item brush against the conveyor antenna as shown in Figure 6. Figure 6: Conveyor Antenna used as a Guide CAUTION: Metallic or conductive parts must not be located less than 300 mm. around the active areas of the Conveyor Antenna. April 2004 Revision 1.0 17/26 Conveyor Antenna for 270 TL Installation Guide 4.4 Installing the TR-L100 Reader Unit Once fixed on the conveyor, the 2 BNC cables of the Conveyor Antenna must be connected (randomly) to Channels 1 and 2 of the Medio L100 reader. CAUTION: The reader unit MUST be switched OFF before connecting or disconnecting the antenna. 4.5 Installing the Signal/Buzzer Box A Signal box (optional) is also available for textile rental and laundry applications. This box is equipped with two signal lamps (green and white) and a buzzer. Delivered with a 6meter long cable, this Signal Box is easily connected to the I/O ports of the TR-L100 Reader. The L200 Explorer software provides a user-friendly configuration system. The I/O ports and power connections are located on the front panel of the TR-L100 Reader. Figure 7: Signal Box In general, the buzzer and green lamp are used to signal that a tag has been correctly read. The white lamp generally means that the reader unit is switched on or that the tag-reading timeslot is open. Table 3: Signal Box Connections Signal Box Wire TR-L100 Connection Description White (White Lamp) I/O Port 2 Lights when Trigger is On Green (Green Lamp) I/O Port 3 Lights when Tag Read is OK I/O Port 3 Sounds when Tag Read is OK I/O Port 4 Sounds when Tag Read is not OK VOUT Power Supply Black (Buzzer) Red (Power) Note that VOUT must be connected to VIN. The I/O ports are easily configured using the L200 Explorer software. For more information, refer to the TR-L100 Reader or L200 Explorer User's Guides. 18/26 Revision 1.0 September 20034 Installation 4.6 Cabling Requirements All Conveyor Antenna cables must be correctly shielded. The shielding effectiveness of the material used should be of good performance (at least 60 dB), especially in the frequency range of 10 to 60 MHz. The addition of ferrite clamps near the reader unit will increase common mode rejection. TAGSYS antenna products are delivered with good performance shielded coaxial cables with 6 ferrite beads already mounted to increase shielding effectiveness at low frequencies (Figure 9). 4.7 Installation Test After setup, an installation test has to be done to ensure proper functioning: 1. Place 10 pieces of each of the different garment types on the conveyor. Check that the tags are attached to each garment as specified for actual conveyor antenna configuration. 2. Run the conveyor. 3. Check that each garment is read. 4. Repeat this procedure 10 times (1000 possible readings). 5. A read rate greater than 98% means the installation is OK. April 2004 Revision 1.0 19/26 Conveyor Antenna for 270 TL Installation Guide 5 Maintenance 5.1 Servicing the Conveyor Antenna CAUTION: The Conveyor Antenna contains no operator serviceable parts and must only be serviced by qualified personnel. No regular servicing is required, except for keeping the unit clean. It is recommended that an approved TAGSYS technical representative inspect the electronics unit at least once per year. 5.2 Servicing the Reader Unit CAUTION: The Reader Unit contains no operator serviceable parts and must only be serviced by qualified personnel. No regular servicing is required, except for keeping the unit clean. It is recommended that an approved TAGSYS technical representative inspect the electronics unit at least once per year. 5.3 Servicing the Signal Box CAUTION: The Signal Box contains no operator serviceable parts and must only be serviced by qualified personnel. No regular servicing is required, except for keeping the unit clean. It is recommended that an approved TAGSYS technical representative inspect the electronics unit at least once per year. 20/26 Revision 1.0 September 20034 Technical Data 6 Technical Data 6.1 Mechanical Characteristics Description Value Housing Plastic ABS UL 94-V0 Dimensions 998 x 418 x 34 mm. (39 Weight 8 kg. (17.6 lb.) Color Pantone P536 Blue Protection Class IP 21 Operating Temperature 0 °C to 55 °C (32 °F to 131 °F) Storage Temperature -25 °C to +60 °C (-130 °F to 140 °F) x 16 x 1½ in.) Figure 8: Conveyor Antenna Mechanical Diagram (Mounting Hole Dimensions) 350 mm. 970 mm. April 2004 Revision 1.0 21/26 Conveyor Antenna for 270 TL Installation Guide 6.2 Electrical Characteristics Description Value Input Power Absolute Maximum Rating 8.0 W Max. with TR-CA7 Configuration 2.0 W Max. with TR-CA8 Configuration 2.0 W Operating Frequency 13.56 MHz Impedance 50±5 Ω and 0°±5° Antenna Connection Standard 50-Ohm, BNC connection Antenna Connection cables Standard 50-Ohm, RG-58 cable (3 m. long) with 6 ferrite beads at the reader unit end. Typical Performances (*) Reading: 140 mm. (*) Laboratory test results using a Medio L100 reader and an Ario 10TL tag in a standard upright configuration. Tag placed in the middle of any of two active areas of the dual 120 x 470 mm. configuration. CAUTION: Only use recommended cable with correct shielding for Signal Box. The Conveyor Antenna must be connected to the TR-L100 Reader unit using only the supplied RG-58 cable with 6 ferrite beads fastened at the reader unit end. Figure 9: Ferrite Beads with TR-L100 Reader For optimum performance in Industrial Laundry and Textile Rental applications using a Medio L100 reader, apply a typical transmitting power of 3 W and 4 W maximum. 22/26 Revision 1.0 September 20034 Warranty Conditions 7 Warranty Conditions 7.1 Warranty TAGSYS warrants that its Conveyor Antenna (Product) shall comply with the functional specifications set forth herein for a period of one year from the date of delivery to the Buyer. This warranty is valid for the original Buyer of the Product and is not assignable or transferable to any other party. TAGSYS cannot be responsible in any way for, and disclaims any liability in connection with the operation or performance of: § any product in which the Product is incorporated; § any equipment not supplied by TAGSYS which is attached to or used in connection with the Product; or, § the Product with any equipment. This warranty only applies to the Product and excludes all other equipment. Optimal operation and performance of the Product are obtained by using TAGSYS’ readers, by applying TAGSYS installation guidelines and by having your installation reviewed by a TAGSYS’ technical consultant. The TAGSYS warranty does not cover the installation, maintenance or service of the Product and is strictly limited to the replacement of Products considered as defective by TAGSYS and returned according to the return procedure defined below; in such case, TAGSYS will, at TAGSYS’ option, either replace every defective Product by one new Product or refund the purchase price paid by Buyer to TAGSYS for the defective Product. 7.1.1 Warranty Exclusions The following conditions are not covered under the warranty: § Defects or damages resulting from storage of the Product under conditions that do not comply with TAGSYS specifications or normal usage. § Defects or damages resulting from use of the Product in abnormal conditions (abnormal conditions being defined as any conditions exceeding the ones stated in the product specifications). § Defects or damages from misuse, accident or neglect. § Defects from improper testing, operation, maintenance or installation. § Defects from alteration, modification except modifications or adjustments specifically described in this Product reference guide, adjustment or repair, or any attempt to do any of the foregoing, by anyone other than TAGSYS. § Any action on the product that prevents TAGSYS to perform an inspection and test of the Product in case of a warranty claim. § Tampering with or abuse of the Product. § Any use or incorporation by the Buyer or a third party of TAGSYS’ Product into life saving or life support devices or systems, or any related products; TAGSYS expressly excludes any liability for such use. April 2004 Revision 1.0 23/26 Conveyor Antenna for 270 TL Installation Guide 7.1.2 General Provisions This warranty sets forth the full extent of TAGSYS responsibility regarding the Product. In any event, TAGSYS warranty is strictly limited to (at TAGSYS’ sole option) the replacement or refund of the Products purchase price to TAGSYS, of Products considered as defective by TAGSYS. The remedy provided above is in lieu and to the exclusion of all other remedies, obligations or liabilities on the part of TAGSYS for damages, whether in contract, tort or otherwise, and including but not limited to, damages for any defects in the Products or for any injury, damage, or loss resulting from such defects or from any work done in connection therewith or for consequential loss, whether based upon lost goodwill, lost resale profits, impairment of other goods or arising from claims by third parties or otherwise. TAGSYS disclaims any explicit warranty not provided herein and any implied warranty, guaranty or representation as to performance, quality and absence of hidden defects, and any remedy for breach of contract, which but for this provision, might arise by implication, operation of law, custom of trade or course of dealing, including implied warranties of merchantability and fitness for a particular purpose. 7.1.3 How to Return Defective Products The Buyer shall notify TAGSYS of the defects within 15 working days after the defects are discovered. Defective Products must be returned to TAGSYS after assignment by a TAGSYS Quality Department representative of an RMA (Return Material Authorization) number. No Products shall be returned without their proof of purchase and without the acceptance number relating to the return procedure. All Products shall be returned with a report from the Buyer stating the complete details of the alleged defect. Call +33 4 91 27 57 36 for return authorization and shipping address. If returned Products prove to be non-defective, a charge will be applied to cover TAGSYS’ analysis cost and shipping costs. If the warranty does not apply for returned Products (due to age, or application of a warranty exclusion clause), a quote for replacement will be issued, and no replacement will be granted until a valid purchase order is received. If no purchase order is received within 30 days after the date of TAGSYS quote, TAGSYS will return the products and charge the analysis cost and shipping costs. All replaced Products shall become the property of TAGSYS. The Product Return Form is included on the following page. This form should accompany any product you need to return to TAGSYS for analysis in the event of a problem. 24/26 Revision 1.0 September 20034 Warranty Conditions Product Return Form Customer Profile: Company: ............................................................... Address: ................................................................. ............................................................................... ............................................................................... City & State:............................................................ Contact Name: ....................................................... Contact e-mail: ...................................................... Contact Phone: ...................................................... Contact Fax: .......................................................... Zip Code:................................................................ Country:.................................................................. Order identification: Product Name:........................................................ Invoice Number: ..................................................... Order Number (OEF): ............................................. Return Quantity: .................................................... Parcel Pick up : Length: ................................................................... Height: ............................................................... Width : ................................................................... Weight: .............................................................. Address to collect the parcel : ................................................................................................................................................................... ................................................................................................................................................................... ................................................................................................................................................................... ................................................................................................................................................................... Contact: ................................................................. Phone: .............................................................. . Reason for return: ................................................................................................................................................................... ................................................................................................................................................................... ................................................................................................................................................................... ................................................................................................................................................................... ................................................................................................................................................................... To inform TAGSYS of this return, please email it to: valerie.guenegan@tagsys.net and to catherine.thouvenin@tagsys.net or fax it to your Quality Service representative at +33 (0) 4 91 27 57 02 Address to ship the product: TAGSYS 180, chemin de Saint Lambert 13821 La Penne sur Huveaune FRANCE Return Procedure April 2004 Revision 1.0 25/26 Conveyor Antenna for 270 TL Installation Guide The product returned will go through stringent quality controls. A final analysis report will be sent to you as soon as possible. Please contact your Quality Service representative for further details at +33 (0) 4 91 27 57 36 26/26 Revision 1.0 September 20034
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 26 Creator : Microsoft Word Create Date : 2004:05:05 10:34:26 Title : ConveyAntInstall270.PDF Author : labo Producer : Acrobat PDFWriter 4.0 pour WindowsEXIF Metadata provided by EXIF.tools