Thales ATM 435 LICENSED NON-BROADCAST TRANSMITTER User Manual USERS MANUAL 1

Thales ATM LICENSED NON-BROADCAST TRANSMITTER USERS MANUAL 1

Contents

USERS MANUAL 1

Download: Thales ATM 435 LICENSED NON-BROADCAST TRANSMITTER User Manual USERS MANUAL 1
Mirror Download [FCC.gov]Thales ATM 435 LICENSED NON-BROADCAST TRANSMITTER User Manual USERS MANUAL 1
Document ID857502
Application IDLUsEAjAPfOPo//h6moF33A==
Document DescriptionUSERS MANUAL 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize141.28kB (1766018 bits)
Date Submitted2007-10-22 00:00:00
Date Available2007-12-07 00:00:00
Creation Date2006-03-17 15:13:33
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2007-09-05 14:16:11
Document TitleMicrosoft Word - DME 400 STD eng vol 1 sect01 Gen Inform sept05 _jan06ok_.doc
Document CreatorAcrobat PDFMaker 7.0.5 for Word

Description, Installation, Operation, Maintenance
Reference: Vol. 1 Code 955 900 031C
GROUND BEACON
DME 415/435
Technical Manual
VOLUME 1
Equipment description, Installation, Operation, Maintenance and PC user
SECTION 1
GENERAL INFORMATION
Vers. D, September 2005
THALES Italia S.p.A.- Air Systems Division
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
1-II
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table of CONTENTS
Paragraph
Page
SECTION 1............................................................................................................................................1-1
GENERAL INFORMATION....................................................................................................1-1
1.1
INTRODUCTION ..............................................................................................................1-1
1.2
DME PRINCIPLE ..............................................................................................................1-1
1.2.1
Coverage ..........................................................................................................................1-2
1.2.2
Traffic Capacity .................................................................................................................1-2
1.2.3
Accuracy ...........................................................................................................................1-2
1.2.4
Nominal Reply Delay – Pair Pulse Code - Channeling.....................................................1-2
1.3
GENERAL FEATURES OF THE EQUIPMENT................................................................1-13
1.3.1
Equipment Versions..........................................................................................................1-13
1.3.2
Main Feature of the Equipment ........................................................................................1-13
1.3.2.1
Engineering.......................................................................................................................1-14
1.3.2.2
Safety ................................................................................................................................1-14
1.3.2.3
Installation.........................................................................................................................1-14
1.3.2.4
Operation ..........................................................................................................................1-14
1.4
BEACON COMPOSITION AND IDENTIFICATION..........................................................1-16
1.5
PHYSICAL AND MECHANICAL general Description.......................................................1-19
1.6
EQUIPMENT FUNCTIONAL DESCRIPTION...................................................................1-26
1.6.1
General Overview .............................................................................................................1-26
1.6.2
DME 415/435 System Functional Description ..................................................................1-27
1.6.3
I/O SYSTEM - Functional description ...............................................................................1-31
1.6.3.1
I/O Local site .....................................................................................................................1-31
1.6.3.2
LOCAL CONTROL & STATUS UNIT (LCSU) ..................................................................1-34
1.6.3.2.1
CONTROL AND STATUS BOARD - CSB module – Functional description....................1-36
1.6.3.2.1.1 CPU and Memories...........................................................................................................1-37
1.6.3.2.1.2 Serial Lines .......................................................................................................................1-40
1.6.3.2.1.3 Parallel ports .....................................................................................................................1-41
1.6.3.2.2
LOCAL FRONT CONTROL PANEL .................................................................................1-44
1.6.3.2.2.1 INDICATION AND CONTROLS - INC Module - functional description............................1-45
1.6.3.3
REMOTE CONTROL SYSTEM ........................................................................................1-48
1.6.3.3.1
Remote Control & Status Indicator (RCSI 446) ................................................................1-50
1.6.3.3.2
Remote Control and Status Equipment (RCSE)...............................................................1-51
1.6.3.3.3
MCS ..................................................................................................................................1-52
1.6.3.4
Status Indicator SI 446......................................................................................................1-53
1.6.3.5
Personal Computer - PC...................................................................................................1-54
1.6.4
TRANSPONDER – Functional description .......................................................................1-55
1.6.4.1
General Overviews ...........................................................................................................1-55
1.6.4.1.1
Pilot Pulse .........................................................................................................................1-55
1.6.4.1.2
Transponder Main Delay Measurement ...........................................................................1-55
1.6.4.2
RECEIVER - RX module...................................................................................................1-60
1.6.4.2.1
UHF coupler (pilot pulse mixer) and 63 MHz Oscillator....................................................1-61
1.6.4.2.2
UHF Front End & 63 MHz linear amplification ..................................................................1-61
1.6.4.2.3
Synthesizer .......................................................................................................................1-62
1.6.4.2.4
Programmable attenuators ...............................................................................................1-62
1.6.4.2.5
Logarithmic Amplifier ........................................................................................................1-63
1.6.4.2.6
On channel validation (OCV) ............................................................................................1-63
1.6.4.2.7
RX reference power supply ..............................................................................................1-63
1.6.4.2.8
Digital circuitry and data bus,............................................................................................1-64
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-a
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Paragraph
1.6.4.3
1.6.4.3.1
1.6.4.3.2
1.6.4.3.3
1.6.4.3.4
1.6.4.3.5
1.6.4.3.6
1.6.4.3.7
1.6.4.3.8
1.6.4.3.9
1.6.4.4
1.6.4.4.1
1.6.4.4.1.1
1.6.4.4.1.2
1.6.4.4.1.3
1.6.4.4.2
1.6.4.4.3
1.6.4.4.4
1.6.4.4.4.1
1.6.4.4.5
1.6.4.4.6
1.6.4.4.7
1.6.4.4.8
1.6.4.5
1.6.4.5.1
1.6.4.5.2
1.6.4.5.3
1.6.4.5.4
1.6.4.5.5
1.6.4.5.6
1.6.4.5.7
1.6.4.6
1.6.4.6.1
1.6.4.6.2
1.6.4.6.3
1.6.4.6.4
1.6.4.6.5
1.6.4.6.6
1.6.4.7
1.6.5
1.6.5.1.1
1.6.5.1.2
1.6.5.1.3
1.6.5.1.4
1.6.5.1.5
1.6.6
1.6.6.1
1.6.6.2
1.6.6.3
1.6.6.3.1
1-b
Page
SIGNAL PROCESSOR - DPR module ............................................................................ 1-66
Analog Input, TOA & Delay Compare ............................................................................. 1-68
On-channel validate ......................................................................................................... 1-69
Decoder and Dead Time .................................................................................................. 1-69
Echo suppression............................................................................................................. 1-70
Main Delay & Priority Circuit............................................................................................. 1-71
Keyer and 1350 Hz Generator ......................................................................................... 1-71
Squitter Generator........................................................................................................... 1-72
DPR reference power supply ........................................................................................... 1-72
Digital Input circuitry and Data bus .................................................................................. 1-72
MODULATOR – DMD module ......................................................................................... 1-73
Microprocessor and Peripherals ...................................................................................... 1-75
Watchdog and Power-On Reset ...................................................................................... 1-75
Serial Communication Controller ..................................................................................... 1-75
Internal Timers ................................................................................................................. 1-75
Coded Gaussian former & Pedestal Modulation Generators........................................... 1-75
Coded Square Gates Modulation..................................................................................... 1-76
Scan & Calibration Counters and reply delay Fine compensation.................................. 1-76
Overload Protection.......................................................................................................... 1-77
Acquisition Process .......................................................................................................... 1-77
Modulation signals measurements................................................................................... 1-77
DMD reference power supply........................................................................................... 1-77
Digital Input and Data bus ................................................................................................ 1-78
TRANSMITTER -TX 100 module ..................................................................................... 1-79
RF amplifiers chain circuits .............................................................................................. 1-79
Video Modulation amplifiers ............................................................................................. 1-79
Detectors circuits.............................................................................................................. 1-81
Pulse Duration Protection circuits .................................................................................... 1-81
Dedicated Power supply for RF amplifiers and TX100 ref. voltage power supply ........... 1-82
Circuits for measurement and diagnostic purpose........................................................... 1-83
Digital signals and Data bus............................................................................................. 1-83
1kWp RF POWER AMPLIFIER – TKW module (only DME 435)..................................... 1-84
RF amplifiers .................................................................................................................... 1-84
Detectors circuits.............................................................................................................. 1-87
Pulse Duration Protection circuits .................................................................................... 1-87
Dedicated 50V Power supply for RF amplif. and TKW ref. voltage power supply ........... 1-87
Circuits for measurement and diagnostic purpose........................................................... 1-88
Digital signals and Data bus............................................................................................. 1-88
TRANSPONDER POWER SUPPLY (+5V & ±15V) – PWS module............................... 1-90
RF PATH AND DUPLEXER – DPX module – Functional description ............................. 1-91
RF electronic switch circuitry............................................................................................ 1-92
Coupler detecting the pilot pulse and the coupler of the monitor-interrogator ................. 1-92
Video driver of RF switches commands........................................................................... 1-92
DPX reference power supply............................................................................................ 1-93
Patch Panel ...................................................................................................................... 1-94
MONITOR SYSTEM......................................................................................................... 1-96
Monitor Reply Delay measurement.................................................................................. 1-97
MONITOR - MON module – Functional description......................................................... 1-99
RF Analog Group ............................................................................................................. 1-99
Frequency synthesizer ..................................................................................................... 1-101
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Paragraph
1.6.6.3.2
1.6.6.3.3
1.6.6.3.4
1.6.6.3.5
1.6.6.3.6
1.6.6.4
1.6.6.4.1
1.6.6.5
1.6.6.5.1
1.6.6.5.2
1.6.6.5.3
1.6.6.5.4
1.6.6.5.5
1.6.6.5.6
1.6.6.6
1.6.6.6.1
1.6.6.6.2
1.6.6.6.3
1.6.6.7
1.6.6.7.1
1.6.6.7.2
1.6.6.8
1.6.6.9
1.6.6.9.1
1.6.6.9.2
1.6.7
1.6.7.1
1.6.7.2
1.6.7.2.1
1.6.7.2.2
1.6.7.2.3
1.6.8
1.6.8.1
1.6.9
1.6.9.1
1.6.9.2
1.6.9.2.1
1.6.9.2.2
1.6.10
Page
59MHz oscillator & Linear modulator................................................................................1-102
Digital Attenuator ..............................................................................................................1-102
Mixer FRX - Filter & UHF Amplifier.....................................................................................1-103
Input-Output selector ........................................................................................................1-103
Linear 63 MHz Detector ....................................................................................................1-106
Analog/digital video section ..............................................................................................1-107
Acquisition ad Generation.................................................................................................1-107
Parallel line and serial line interface .................................................................................1-110
Status signals from Transponders ....................................................................................1-111
Commands to Transponders ............................................................................................1-111
Status signals from the Antenna - Dummy Load Switch (Duplexer) ................................1-111
Commands to the Antenna - Dummy Load Switch (Duplexer).........................................1-111
Signals Exchanging with the other Monitor.......................................................................1-111
Other signals from/to Transponders .................................................................................1-112
CPU and Digital processor ...............................................................................................1-112
Serial connection with LCSU unit .....................................................................................1-113
Automatic cycle.................................................................................................................1-113
Monitor Reply Delay measurement ..................................................................................1-114
Morse code (MORCO) decoder........................................................................................1-114
Identification code .............................................................................................................1-114
Morse code detector .........................................................................................................1-115
MON reference power supply ...........................................................................................1-115
MONITOR SOFTWARE PROGRAM................................................................................1-115
Automatic Monitoring Operation .......................................................................................1-115
Automatic & Semi-Automatic Testing ...............................................................................1-116
INTERFACE SYSTEM – Functional description ..............................................................1-117
Associated Facility Interface - AFI module .......................................................................1-117
Modem (MDM) ..................................................................................................................1-118
Modem Level Adapter interface........................................................................................1-118
Switched and dedicated line Modem - LGM28,8..............................................................1-118
Dedicated Line Modem LGM1200MD – Party line ...........................................................1-120
COAXIAL RELAY – KCX module .....................................................................................1-121
TAI dummy – Interface module.........................................................................................1-121
POWER SUPPLY SYSTEM – Functional description ......................................................1-121
BCPS unit .........................................................................................................................1-123
Power supply with BCPS subrack Frako type (optional) .................................................1-125
AC/DC module – AC-DC converter (type Frako optional) ................................................1-127
Battery Supervisor module ...............................................................................................1-128
DME ANTENNA................................................................................................................1-129
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-c
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
List of FIGURES
Figure
Page
Figure 1.1. DME - Principle of the RF signals path ............................................................................. 1-1
Figure 1.2. DME - Theory of operation, simplified block diagram ....................................................... 1-2
Figure 1.3. DME Channels Reply and Interrogation Frequencies....................................................... 1-3
Figure 1.4. DME 415 (same as DME 435) – Cabinet and PC, example of arrangement.................... 1-15
Figure 1.5. DME 435 – Front view with anterior door opened – Full Dual version ............................. 1-21
Figure 1.6. DME 415 – Front view with anterior door opened – Full Dual version .............................. 1-22
Figure 1.7. DME 435 Single version – Front view with anterior door opened ..................................... 1-23
Figure 1.8. DME 435 – Rear side view of the cabinet ......................................................................... 1-24
Figure 1.9. DME 415/435 – Top view .................................................................................................. 1-25
Figure 1.10. DME 415/435 – Simplified general block diagram .......................................................... 1-28
Figure 1.11. DME 415/435 – Main RF path signals - General simplified block diagram..................... 1-29
Figure 1.12. DME 415/435 – Local I/O system general block diagram ............................................... 1-30
Figure 1.13. DME 415/435 – AC/DC Power Supply system & Battery Charge - Block diagram......... 1-30
Figure 1.14. I/O Panel.......................................................................................................................... 1-32
Figure 1.15. Local site set up – Typical configuration ......................................................................... 1-33
Figure 1.16. LCSU - Simplified Block Diagram.................................................................................... 1-34
Figure 1.17. CSB module – Simplified Block Diagram ........................................................................ 1-35
Figure 1.18. CSB module – General Block Diagram ........................................................................... 1-37
Figure 1.19. CSB module – CPU and Memories: Block Diagram ....................................................... 1-39
Figure 1.20. CSB module – Serial lines: Block Diagram ..................................................................... 1-41
Figure 1.21. CSB module – I/O Parallel Ports: Block Diagram............................................................ 1-43
Figure 1.22. Local Front Panel ............................................................................................................ 1-45
Figure 1.23. INC module - simplified block diagram............................................................................ 1-46
Figure 1.24. INC Module - Indication and Control: General Block Diagram........................................ 1-46
Figure 1.25. INC Module - Indication and Control: Block Diagram...................................................... 1-47
Figure 1.26. Possible connection between Remote RCSI/RCSE and Local site ................................ 1-48
Figure 1.27. Example of single site connection with RCSI .................................................................. 1-49
Figure 1.28. Example of multi site connection with RCSI.................................................................... 1-49
Figure 1.29. Example of multi site connection with RCSE .................................................................. 1-50
Figure 1.30. RCSI-8 – Remote control ................................................................................................ 1-51
Figure 1.31. RCSE 443 – Remote control ........................................................................................... 1-51
Figure 1.32. RCSE 443 – Remote control CTU & RunWay select...................................................... 1-52
Figure 1.33. MCS – Remote control .................................................................................................... 1-52
Figure 1.34. SI446-2 and SI 446-8 - Front panel view......................................................................... 1-53
Figure 1.35. Example of connections between beacon and PC with RCSI/RCSE.............................. 1-54
Figure 1.36. DME 415/435 TRANSPONDER– General block diagram of the main signals ............... 1-56
Figure 1.37. DME 415/435 TRANSPONDER– Main Delay Measurement and compensation ........... 1-57
Figure 1.38. DME 415/435 TRANSPONDER– General block diagram .............................................. 1-58
Figure 1.39. RX module – General block diagram .............................................................................. 1-59
Figure 1.40. RX - Layout location in the extrusion of the Analog RF .................................................. 1-60
Figure 1.41. RX - Receiver Coupler and 63 MHz oscillator block diagram ......................................... 1-61
Figure 1.42. RX – Front End and 63 MHz linear amplif. - Block diagram............................................ 1-61
Figure 1.43. RX – Frequency Synthesizer & RF Amplifier - Block diagram ........................................ 1-62
Figure 1.44. RX – IF programmable digital Attenuator - Block diagram.............................................. 1-63
Figure 1.45. RX – 63 MHz logarithmic amplifiers - Block diagram ...................................................... 1-64
Figure 1.46. RX – Digital circuitry and data bus block diagram........................................................... 1-65
Figure 1.47. DPR module – General block diagram............................................................................ 1-67
Figure 1.48. DPR – TOA & Delay-Compare – Block diagram ............................................................. 1-68
1-d
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Figure
Figure 1.49.
Figure 1.50.
Figure 1.51.
Figure 1.52.
Figure 1.53.
Figure 1.54.
Figure 1.55.
Figure 1.56.
Figure 1.57.
Figure 1.58.
Figure 1.59.
Figure 1.60.
Figure 1.61.
Figure 1.62.
Figure 1.63.
Figure 1.64.
Figure 1.65.
Figure 1.66.
Figure 1.67.
Figure 1.68.
Figure 1.69.
Figure 1.70.
Figure 1.71.
Figure 1.72.
Figure 1.73.
Figure 1.74.
Figure 1.75.
Figure 1.76.
Figure 1.77.
Figure 1.78.
Figure 1.79.
Figure 1.80.
Figure 1.81.
Figure 1.82.
Figure 1.83.
Figure 1.84.
Figure 1.85.
Figure 1.86.
Figure 1.87.
Figure 1.88.
Figure 1.89.
Figure 1.90.
Figure 1.91.
Figure 1.92.
Figure 1.93.
Figure 1.94.
Figure 1.95.
Figure 1.96.
Figure 1.97.
Figure 1.98.
Page
DPR – Decoder & Dead Time – Simplified Block diagram ..............................................1-70
DPR – Main Delay, keyer & Priority Circuit – Simplified Block diagram ..........................1-71
DPR – Squitter generator – Simplified Block diagram .....................................................1-72
DPR – Digital circuitry and data bus - Block diagram ......................................................1-72
DMD module – General Block diagram ...........................................................................1-74
DMD – Bus system - Block diagram ................................................................................1-78
TX100 module – General block diagram .........................................................................1-80
TX100 – Layout location of main functional blocks..........................................................1-81
TX100 – Pulse duration protection circuits ......................................................................1-82
TX100 – Dedicated power supply ....................................................................................1-82
TX100 – Digital circuits – Block Diagram.........................................................................1-83
TKW – RF stages Matching Network – Block Diagram ...................................................1-84
TKW module – General block diagram ............................................................................1-85
TKW – Main Components Location .................................................................................1-86
TKW – Pulse Duration Protection circuits ........................................................................1-87
TKW – Dedicated power supply.......................................................................................1-88
TKW – Digital circuits – Block Diagram ...........................................................................1-89
PWS module – General Block Diagram...........................................................................1-90
DPX module – Simplified Block Diagram.........................................................................1-91
DPX – RF circuits Block Diagram ....................................................................................1-92
DPX– Video circuits – Simplified Block diagram..............................................................1-93
DPX– Video circuits – Example of PIN diodes commands..............................................1-93
DPX Ref. Power Supply – Simplified Block diagram .......................................................1-94
DPX & Patch panel – Frontal view...................................................................................1-94
DPX & Patch Panel – Simplified Block diagram ..............................................................1-95
DME 415/435 - MONITOR system – Simplified block diagram .......................................1-97
DME 415/435 - MONITOR – Reply Delay Measurement ................................................1-98
MONITOR – Location of the RF stages on the casting ...................................................1-99
MONITOR – Analog RF group - Block diagram...............................................................1-100
MONITOR – Synthesizer – Simplified block schematic diagram.....................................1-101
MONITOR – Synthesizer – Block diagram ......................................................................1-101
MONITOR – 59 MHz oscillator & Linear modulator – Block diagram..............................1-102
MONITOR – Digital Attenuator – Block diagram .............................................................1-102
MONITOR – Mixer FRX - Filter & UHF Amplifier – Block diagram....................................1-103
MONITOR – Input-Output RF selector – General Block diagram....................................1-104
MONITOR – Input-Output RF selector – Detailed Block diagrams .................................1-105
MONITOR – Linear Detector - Block diagram .................................................................1-106
MONITOR – Acquisition and Generation - General Block diagram.................................1-107
MONITOR – Parallel line and serial line interface - General Block diagram ..................1-110
MONITOR – CPU and Digital processor - Block diagram ...............................................1-112
MONITOR – Morse code decoder - Block diagram .........................................................1-114
AFI module - Association Facility Interface – Simplified Block Diagram .........................1-118
Modem Level adapter - Block diagram ............................................................................1-118
LGM 28,8 MODEM – Simplified Block Diagram ..............................................................1-119
LGM1200MD Modem, block diagram ..............................................................................1-120
Transfer relay, block diagram ..........................................................................................1-121
EQUIPMENT POWER SUPPLY SYSTEM – General Block Diagram ............................1-122
BCPS unit – Simplified Block Diagram ...........................................................................1-123
BCPS unit – AC/DC module - Schematic block diagram................................................1-124
BCPS unit – AC/DC module - Auxiliary voltage - Schematic block diagram ..................1-124
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-e
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Figure
Page
Figure 1.99. BCPS unit – AC/DC module - Sharing current circuitry - Schematic block diagram...... 1-125
Figure 1.100. Power Supply with BCPS Frako type – Simplified Block Diagram................................ 1-125
Figure 1.101. Power Supply with BCPS Frako type – Front and Rear view ....................................... 1-126
Figure 1.102. BCPS Frako type AC/DC module – General block diagram ......................................... 1-127
Figure 1.103. Battery Supervisor: Protection Circuit - Block Diagram................................................. 1-128
Figure 1.104. DME ANTENNA ............................................................................................................ 1-130
List of TABLES
Table
Page
Table 1-1. Frequencies for DME Channels .......................................................................................... 1-3
Table 1-2. Frequencies and Code Pulses for DME Channels (1 to 17) ............................................... 1-4
Table 1-2. Frequencies and Code Pulses for DME Channels (18 to 28) ............................................. 1-5
Table 1-2. Frequencies and Code Pulses for DME Channels (29 to 40) ............................................. 1-6
Table 1-2. Frequencies and Code Pulses for DME Channels (41 to 52) ............................................. 1-7
Table 1-2. Frequencies and Code Pulses for DME Channels (53 to 68) ............................................. 1-8
Table 1-2. Frequencies and Code Pulses for DME Channels (69 to 85) ............................................. 1-9
Table 1-2. Frequencies and Code Pulses for DME Channels (86 to 99) ............................................. 1-10
Table 1-2. Frequencies and Code Pulses for DME Channels (100 to 113) ......................................... 1-11
Table 1-2. Frequencies and Code Pulses for DME Channels (114 to 126) ......................................... 1-12
Table 1-3. Composition of the Equipment ............................................................................................ 1-16
Table 1-4. User Interface Composition (option).................................................................................... 1-17
Table 1-5. Material Supplied................................................................................................................. 1-18
Table 1-6. RF Interrogation levels by monitors to Rx ........................................................................... 1-106
1-f
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
SECTION 1
GENERAL INFORMATION
1.1
INTRODUCTION
DME (Distance Measuring Equipment) has been standardized by the ICAO as a radio aid for short and
medium-distance navigation. It is a secondary type of radar, which allows several aircraft to simultaneously
measure their distance from a ground reference (DME transponder). The distance is determined by
measuring the propagation delay of a RF pulse, which is emitted by the aircraft transmitter and returned at a
different frequency by the ground station after reception.
In conjunction with a VOR, the DME, which should preferably be installed at the same location as a
VOR/DME, enables to determine the direction and the distance (rho-theta method).
Since the DME operates in the same frequency range (960 to 1215 MHz) and according to the same
principle as the distance measuring section of the TACAN, combined VOR/TACAN systems (VORTAC) are
installed in many countries, as well as VOR/DME systems.
1.2
DME PRINCIPLE
Aircraft's equipped with DME transmit encoded interrogating RF pulse pairs on the beacon's receiving
channel. The beacon, in turn, emits encoded reply pulse pairs on the receiving channel of the air-borne
equipment, which is 63 MHz apart from the transmitter frequency former.
The time interval between interrogation emission and reply reception provides the aircraft with the real
distance information from the ground station; this information may be read by the pilot or the navigator
directly on the airborne indicator.
The ground transponder is able to answer up to about 200 interrogators at a time (i.e. 4800 pulse pairs/s).
Generates random pulse pairs ("squitter") to maintain a minimum PRF of 800 to 2700 pulse pairs per
second (programmable) whenever the number of decoded interrogations is lower than that.
This reply is received and decoded by the airborne receiver, where special timing circuits automatically
measure the lapse between interrogation and reply and convert this measurement into electrical output
signals. The beacon introduces a fixed delay, called reply delay, between the reception of each encoded
interrogating pulse pair and the transmission of the corresponding reply ( see Figure 1.1).
Travel time (50µs+1µs/150m)
Interrogation Paire pulses
transmitted by aircraft
One way time
1µs/300m
Interrogation Paire pulses
received by transponder
Replay Delay of the beacon
(50µs)
Replay delay Paire pulses
transmitted by transponder
One way time
1µs/300m
Replay Paire pulses
received by aircraft
Figure 1.1. DME - Principle of the RF signals path
The transponder periodically transmits special identification pulse groups, interleaved with the reply and
squitter pulses that can be decoded by the aircraft as a Morse tone, keyed with the beacon code name.
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-1
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
The airborne receiver is able to recognize the replies to its own interrogations, among the many other pulses
transmitted by the beacon, by means of a stroboscopic procedure.
The DME theory of operation is summarized in a block diagram in Figure 1.2.
AIRCRAFT'S
ANTENNA
BEACON'S
ANTENNA
TRANSMITS DISTANCE
INFORMATION
and IDENTIFICATION
SIGNAL
RECEIVED
INTERROGATIONS
AUTOPILOT
TRANSMITTER
RECEIVER
DISTANCE
CIRCUITS
DISTANCE INFORMATION
TO BOARD INDICATOR
INTERROGATION
TRIGGERS
DME
AIRBORNE
REPLY TRIGGER TO
INTERROGATIONS
BEACON
IDENTIFICATION TONE
CHANNEL SELECTOR
RECEIVER
TRANSMITTER
DME GROUND BEACON
Figure 1.2. DME - Theory of operation, simplified block diagram
1.2.1
Coverage
According to the frequency band used, the DME system coverage is limited to the optical range and
depends on the aircraft flight altitude and on the type of ground.
The high frequency used and the use of special techniques have made the system much less sensitive to
site errors than other types of omni-directional beacons now in use.
1.2.2
Traffic Capacity
The aircraft handling capacity is adequate for a traffic peak of 200 aircrafts. When the traffic peak exceeds
200 aircrafts the transponder should be capable of handling that peak.
1.2.3
Accuracy
As a result of the development and the applications of modern electronic technologies, the accuracy of the
distance information provided by the DME system is improving all the time.
At present, the accuracy of a DME system can be considered within the maximum values specified below:
±0.12 NM +0.05% of the distance, from 0 to 65 nautical miles, and ± 0.17 NM +0.05% of the distance, above
65 nautical miles.
1.2.4
Nominal Reply Delay – Pair Pulse Code - Channeling
Each beacon is identified by means of its channel frequency, its pulse coding and its identity signal.
The ground beacon introduces a fixed delay between the reception of interrogating pulses and the
transmission of the corresponding reply pulses.
This fixed delay, called main delay or fundamental delay, is introduced. So that an aircraft which is flying
very close to the beacon can complete transmission of the encoded interrogating pulse pair, and then
deactivate its own transmitter, before its receiver begins receiving the corresponding beacon reply pulses.
To render the system as immune as possible to errors caused by interfering signals, the DME system
transmits pulse pairs instead of single pulses; each pair includes two 3.5 µs pulses whose spacing depends
on the channel mode selected.
The channel code, pulse code, reply delay and operating mode are shown on the following table (standard
ICAO).
1-2
Channel
Code
Nominal
Interrogation Pulse Code
[µs]
Transponder
Reply Pulse Code
[µs]
Transponder
Nominal Reply Delay
[µs]
12
12.0 ± 0.1
50
36
30.0 ± 0.1
56
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Each operational channel in the DME system is defined by two frequencies (interrogation and reply
frequencies), spaced 63 MHz apart, and by the pulse code for the assigned channel (X or Y channel).
The DME system transmits on a pre-selected channel among the 252 available ones. These channels are
divided into 126 X channels and 126 Y channels providing a frequency ranging from 1025 to 1150 MHz for
aircraft transmission (interrogation). Moreover, a 962 to 1213 MHz frequency for signal reception by the
aircraft (ground beacon reply transmission). Interrogation and reply frequencies are assigned with one MHz
spacing between channels.
The diagram shown in figure 1.3 gives the aircraft interrogation frequency associated to the beacon reply
frequency for both channel types X, Y. The same information is also given in table 1-1 and table 1-2 for X
and Y channels respectively, as per ICAO ANNEX 10.
Each beacon emits a Morse identity code signal that can be heard in the pilot headset; this code consists of
pulse pairs transmitted at a frequency of 1350 Hz.
Each beacon is therefore identified by means of its channel frequency, its pulse coding and its identity
signal.
Table 1-1. Frequencies for DME Channels
Channel
X Channels (n° 126)
I = 1025 + (CH-1)
R = I - 63
R = I + 63
1 ≤ CH ≤ 63
64 ≤ CH ≤ 126
I = INTERROGATION FREQUENCY (MHz)
R = REPLY FREQUENCY (MHz)
Y Channels (n° 126)
I = 1025 + (CH-1)
R = I + 63
R = I - 63
CH = CHANNEL NUMBER
960 MHz
1215 MHz
1025 MHz
962 MHz
1088 MHz
1151 MHz
1213 MHz
64-126X
1-63X
1-63Y
64-126Y
INTERROGATION FREQUENCIES
REPLY FREQUENCIES
Figure 1.3. DME Channels Reply and Interrogation Frequencies
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-3
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table 1-2. Frequencies and Code Pulses for DME Channels (1 to 17)
DME PARAMETERS
CHANNEL PAIRING
INTERROGATION
REPLY
Pulse Codes
DME/P
DME
Channel
VHF
FREQ.
MHz
MLS
FREQ.
MHz
MLS
Channel
Frequency
MHz
DME/N
µs
IAM
µs
FAM
µs
Frequency
MHz
Pulse
Codes
µs
1X
1Y
−
−
−
−
−
−
1025
1025
12
36
−
−
−
−
962
1088
12
30
2X
2Y
−
−
−
−
−
−
1026
1026
12
36
−
−
−
−
963
1089
12
30
3X
3Y
−
−
−
−
−
−
1027
1027
12
36
−
−
−
−
964
1090
12
30
4X
4Y
−
−
−
−
−
−
1028
1028
12
36
−
−
−
−
965
1091
12
30
5X
5Y
−
−
−
−
−
−
1029
1029
12
36
−
−
−
−
966
1092
12
30
6X
6Y
−
−
−
−
−
−
1030
1030
12
36
−
−
−
−
967
1093
12
30
7X
7Y
−
−
−
−
−
−
1031
1031
12
36
−
−
−
−
968
1094
12
30
8X
8Y
−
−
−
−
−
−
1032
1032
12
36
−
−
−
−
969
1095
12
30
9X
9Y
−
−
−
−
−
−
1033
1033
12
36
−
−
−
−
970
1096
12
30
10X
10Y
−
−
−
−
−
−
1034
1034
12
36
−
−
−
−
971
1097
12
30
11X
11Y
−
−
−
−
−
−
1035
1035
12
36
−
−
−
−
972
1098
12
30
12X
12Y
−
−
−
−
−
−
1036
1036
12
36
−
−
−
−
973
1099
12
30
13X
13Y
−
−
−
−
−
−
1037
1037
12
36
−
−
−
−
974
1100
12
30
14X
14Y
−
−
−
−
−
−
1038
1038
12
36
−
−
−
−
975
1101
12
30
15X
15Y
−
−
−
−
−
−
1039
1039
12
36
−
−
−
−
976
1102
12
30
16X
16Y
−
−
−
−
−
−
1040
1040
12
36
−
−
−
−
977
1103
12
30
17X
17Y
17Z
108.00
108.05
−
−
5043.0
5043.3
−
540
541
1041
1041
1041
12
36
−
−
36
21
−
42
27
978
1104
1104
12
30
15
1-4
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table 1-2. Frequencies and Code Pulses for DME Channels (18 to 28)
DME PARAMETERS
CHANNEL PAIRING
INTERROGATION
REPLY
Pulse Codes
DME/P
DME
Channel
VHF
FREQ.
MHz
MLS
FREQ.
MHz
MLS
Channel
Frequency
MHz
DME/N
µs
IAM
µs
FAM
µs
Frequency
MHz
Pulse
Codes
µs
18X
18W
18Y
18Z
108.10
−
108.15
−
5031.0
5031.3
5043.6
5043.9
500
501
542
543
1042
1042
1042
1042
12
−
36
−
12
24
36
21
18
30
42
27
979
979
1105
1105
12
24
30
15
19X
19Y
19Z
108.20
108.25
−
−
5044.2
5044.5
−
544
545
1043
1043
1043
12
36
−
−
36
21
−
42
27
980
1106
1106
12
30
15
20X
20W
20Y
20Z
108.30
−
108.35
−
5031.6
5031.9
5044.8
5045.1
502
503
546
547
1044
1044
1044
1044
12
−
36
−
12
24
36
21
18
30
42
27
981
981
1107
1107
12
24
30
15
21X
21Y
21Z
108.40
108.45
−
−
5045.4
5045.7
−
548
549
1045
1045
1045
12
36
−
−
36
21
−
42
27
982
1108
1108
12
30
15
22X
22W
22Y
22Z
108.50
−
108.55
−
5032.2
5032.5
5046.0
5046.3
504
505
550
551
1046
1046
1046
1046
12
−
36
−
12
24
36
21
18
30
42
27
983
983
1109
1109
12
24
30
15
23X
23Y
23Z
108.60
108.65
−
−
5046.6
5046.9
−
552
553
1047
1047
1047
12
36
−
−
36
21
−
42
27
984
1110
1110
12
30
15
24X
24W
24Y
24Z
108.70
−
108.75
−
5032.8
5033.1
5047.2
5047.5
506
507
554
555
1048
1048
1048
1048
12
−
36
−
12
24
36
21
18
30
42
27
985
985
1111
1111
12
24
30
15
25X
25Y
25Z
108.80
108.85
−
−
5047.8
5048.1
−
556
557
1049
1049
1049
12
36
−
−
36
21
−
42
27
986
1112
1112
12
30
15
26X
26W
26Y
26Z
108.90
−
108.95
−
5033.4
5033.7
5048.4
5048.7
508
509
558
559
1050
1050
1050
1050
12
−
36
−
12
24
36
21
18
30
42
27
987
987
1113
1113
12
24
30
15
27X
27Y
27Z
109.00
109.05
−
−
5049.0
5049.3
−
560
561
1051
1051
1051
12
36
−
−
36
21
−
42
27
988
1114
1114
12
30
15
28X
28W
28Y
28Z
109.10
−
109.15
−
5034.0
5034.3
5049.6
5049.9
510
511
562
563
1052
1052
1052
1052
12
−
36
−
12
24
36
21
18
30
42
27
989
989
1115
1115
12
24
30
15
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-5
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table 1-2. Frequencies and Code Pulses for DME Channels (29 to 40)
DME PARAMETERS
CHANNEL PAIRING
INTERROGATION
REPLY
Pulse Codes
DME/P
DME
Channel
VHF
FREQ.
MHz
MLS
FREQ.
MHz
MLS
Channel
Frequency
MHz
DME/N
µs
IAM
µs
FAM
µs
Frequency
MHz
Pulse
Codes
µs
29X
29Y
29Z
109.20
109.25
−
−
5050.2
5050.5
−
564
565
1053
1053
1053
12
36
−
−
36
21
−
42
27
990
1116
1116
12
30
15
30X
30W
30Y
30Z
109.30
−
109.35
−
5034.6
5034.9
5050.8
5051.1
512
513
566
567
1054
1054
1054
1054
12
−
36
−
12
24
36
21
18
30
42
27
991
991
1117
1117
12
24
30
15
31X
31Y
31Z
109.40
109.45
−
−
5051.4
5051.7
−
568
569
1055
1055
1055
12
36
−
−
36
21
−
42
27
992
1118
1118
12
30
15
32X
32W
32Y
32Z
109.50
−
109.55
−
5035.2
5035.5
5052.0
5052.3
514
515
570
571
1056
1056
1056
1056
12
−
36
−
12
24
36
21
18
30
42
27
993
993
1119
1119
12
24
30
15
33X
33Y
33Z
109.60
109.65
−
−
5052.6
5052.9
−
572
573
1057
1057
1057
12
36
−
−
36
21
−
42
27
994
1120
1120
12
30
15
34X
34W
34Y
34Z
109.70
−
109.75
−
5035.8
5036.1
5053.2
5053.5
516
517
574
575
1058
1058
1058
1058
12
−
36
−
12
24
36
21
18
30
42
27
995
995
1121
1121
12
24
30
15
35X
35Y
35Z
109.80
109.85
−
−
5053.8
5054.1
−
576
577
1059
1059
1059
12
36
−
−
36
21
−
42
27
996
1122
1122
12
30
15
36X
36W
36Y
36Z
109.90
−
109.95
−
5036.4
5036.7
5054.4
5054.7
518
519
578
579
1060
1060
1060
1060
12
−
36
−
12
24
36
21
18
30
42
27
997
997
1123
1123
12
24
30
15
37X
37Y
37Z
110.00
110.05
−
−
5055.0
5055.3
−
580
581
1061
1061
1061
12
36
−
−
36
21
−
42
27
998
1124
1124
12
30
15
38X
38W
38Y
38Z
110.10
−
110.15
−
5037.0
5037.3
5055.6
5055.9
520
521
582
583
1062
1062
1062
1062
12
−
36
−
12
24
36
21
18
30
42
27
999
999
1125
1125
12
24
30
15
39X
39Y
39Z
110.20
110.25
−
−
5056.2
5056.5
−
584
585
1063
1063
1063
12
36
−
−
36
21
−
42
27
1000
1126
1126
12
30
15
40X
40W
40Y
40Z
110.30
−
110.35
−
5037.6
5037.9
5056.8
5057.1
522
523
586
587
1064
1064
1064
1064
12
−
36
−
12
24
36
21
18
30
42
27
1001
1001
1127
1127
12
24
30
15
1-6
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table 1-2. Frequencies and Code Pulses for DME Channels (41 to 52)
DME PARAMETERS
CHANNEL PAIRING
INTERROGATION
REPLY
Pulse Codes
DME/P
DME
Channel
VHF
FREQ.
MHz
MLS
FREQ.
MHz
MLS
Channel
Frequency
MHz
DME/N
µs
IAM
µs
FAM
µs
Frequency
MHz
Pulse
Codes
µs
41X
41Y
41Z
110.40
110.45
−
−
5057.4
5057.7
−
588
589
1065
1065
1065
12
36
−
−
36
21
−
42
27
1002
1128
1128
12
30
15
42X
42W
42Y
42Z
110.50
−
110.55
−
5038.2
5038.5
5058.0
5058.3
524
525
590
591
1066
1066
1066
1066
12
−
36
−
12
24
36
21
18
30
42
27
1003
1003
1129
1129
12
24
30
15
43X
43Y
43Z
110.60
110.65
−
−
5058.6
5058.9
−
592
593
1067
1067
1067
12
36
−
−
36
21
−
42
27
1004
1130
1130
12
30
15
44X
44W
44Y
44Z
110.70
−
110.75
−
5038.8
5039.1
5059.2
5059.5
526
527
594
595
1068
1068
1068
1068
12
−
36
−
12
24
36
21
18
30
42
27
1005
1005
1131
1131
12
24
30
15
45X
45Y
45Z
110.80
110.85
−
−
5059.8
5060.1
−
596
597
1069
1069
1069
12
36
−
−
36
21
−
42
27
1006
1132
1132
12
30
15
46X
46W
46Y
46Z
110.90
−
110.95
−
5039.4
5039.7
5060.4
5060.7
528
529
598
599
1070
1070
1070
1070
12
−
36
−
12
24
36
21
18
30
42
27
1007
1007
1133
1133
12
24
30
15
47X
47Y
47Z
111.00
111.05
−
−
5061.0
5061.3
−
600
601
1071
1071
1071
12
36
−
−
36
21
−
42
27
1008
1134
1134
12
30
15
48X
48W
48Y
48Z
111.10
−
111.15
−
5040.0
5040.3
5061.6
5061.9
530
531
602
603
1072
1072
1072
1072
12
−
36
−
12
24
36
21
18
30
42
27
1009
1009
1135
1135
12
24
30
15
49X
49Y
49Z
111.20
111.25
−
−
5062.2
5062.5
−
604
605
1073
1073
1073
12
36
−
−
36
21
−
42
27
1010
1136
1136
12
30
15
50X
50W
50Y
50Z
111.30
−
111.35
−
5040.6
5040.9
5062.8
5063.1
532
533
606
607
1074
1074
1074
1074
12
−
36
−
12
24
36
21
18
30
42
27
1011
1011
1137
1137
12
24
30
15
51X
51Y
51Z
111.40
111.45
−
−
5063.4
5063.7
−
608
609
1075
1075
1075
12
36
−
−
36
21
−
42
27
1012
1138
1138
12
30
15
52X
52W
52Y
52Z
111.50
−
111.55
−
5041.2
5041.5
5064.0
5064.3
534
535
610
611
1076
1076
1076
1076
12
−
36
−
12
24
36
21
18
30
42
27
1013
1013
1139
1139
12
24
30
15
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-7
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table 1-2. Frequencies and Code Pulses for DME Channels (53 to 68)
DME PARAMETERS
CHANNEL PAIRING
INTERROGATION
REPLY
Pulse Codes
DME/P
DME
Channel
VHF
FREQ.
MHz
MLS
FREQ.
MHz
MLS
Channel
Frequency
MHz
DME/N
µs
IAM
µs
FAM
µs
Frequency
MHz
Pulse
Codes
µs
53X
53Y
53Z
111.60
111.65
−
−
5064.5
5064.9
−
612
613
1077
1077
1077
12
36
−
−
36
21
−
42
27
1014
1140
1140
12
30
15
54X
54W
54Y
54Z
111.70
−
111.75
−
5041.8
5042.1
5065.2
5065.5
536
537
614
615
1078
1078
1078
1078
12
−
36
−
12
24
36
21
18
30
42
27
1015
1015
1141
1141
12
24
30
15
55X
55Y
55Z
111.80
111.85
−
−
5065.8
5066.1
−
616
617
1079
1079
1079
12
36
−
−
36
21
−
42
27
1016
1142
1142
12
30
15
56X
56W
56Y
56Z
111.90
−
111.95
−
5042.4
5042.7
5066.4
5066.7
538
539
618
619
1080
1080
1080
1080
12
−
36
−
12
24
36
21
18
30
42
27
1017
1017
1143
1143
12
24
30
15
57X
57Y
112.00
112.05
−
−
−
−
1081
1081
12
36
−
−
−
−
1018
1144
12
30
58X
58Y
112.10
112.15
−
−
−
−
1082
1082
12
36
−
−
−
−
1019
1145
12
30
59X
59Y
112.20
112.25
−
−
−
−
1083
1083
12
36
−
−
−
−
1020
1146
12
30
60X
60Y
−
−
−
−
−
−
1084
1084
12
36
−
−
−
−
1021
1147
12
30
61X
61Y
−
−
−
−
−
−
1085
1085
12
36
−
−
−
−
1022
1148
12
30
62X
62Y
−
−
−
−
−
−
1086
1086
12
36
−
−
−
−
1023
1149
12
30
63X
63Y
−
−
−
−
−
−
1087
1087
12
36
−
−
−
−
1024
1150
12
30
64X
64Y
−
−
−
−
−
−
1088
1088
12
36
−
−
−
−
1151
1025
12
30
65X
65Y
−
−
−
−
−
−
1089
1089
12
36
−
−
−
−
1152
1026
12
30
66X
66Y
−
−
−
−
−
−
1090
1090
12
36
−
−
−
−
1153
1027
12
30
67X
67Y
−
−
−
−
−
−
1091
1091
12
36
−
−
−
−
1154
1028
12
30
68X
68Y
−
−
−
−
−
−
1092
1092
12
36
−
−
−
−
1155
1029
12
30
1-8
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table 1-2. Frequencies and Code Pulses for DME Channels (69 to 85)
DME PARAMETERS
CHANNEL PAIRING
INTERROGATION
REPLY
Pulse Codes
DME/P
DME
Channel
VHF
FREQ.
MHz
MLS
FREQ.
MHz
MLS
Channel
Frequency
MHz
DME/N
µs
IAM
µs
FAM
µs
Frequency
MHz
Pulse
Codes
µs
69X
69Y
−
−
−
−
−
−
1093
1093
12
36
−
−
−
−
1156
1030
12
30
70X
70Y
112.30
112.35
−
−
−
−
1094
1094
12
36
−
−
−
−
1157
1031
12
30
71X
71Y
112.40
112.45
−
−
−
−
1095
1095
12
36
−
−
−
−
1158
1032
12
30
72X
72Y
112.50
112.55
−
−
−
−
1096
1096
12
36
−
−
−
−
1159
1033
12
30
73X
73Y
112.60
112.65
−
−
−
−
1097
1097
12
36
−
−
−
−
1160
1034
12
30
74X
74Y
112.70
112.75
−
−
−
−
1098
1098
12
36
−
−
−
−
1161
1035
12
30
75X
75Y
112.80
112.85
−
−
−
−
1099
1099
12
36
−
−
−
−
1162
1036
12
30
76X
76Y
112.90
112.95
−
−
−
−
1100
1100
12
36
−
−
−
−
1163
1037
12
30
77X
77Y
113.00
113.05
−
−
−
−
1101
1101
12
36
−
−
−
−
1164
1038
12
30
78Y
78Y
113.10
113.15
−
−
−
−
1102
1102
12
36
−
−
−
−
1165
1039
12
30
79X
79Y
113.20
113.25
−
−
−
−
1103
1103
12
36
−
−
−
−
1166
1040
12
30
80X
80Y
80Z
113.30
113.35
−
−
5067.0
5067.3
−
620
621
1104
1104
1104
12
36
−
−
36
21
−
42
27
1167
1041
1041
12
30
15
81X
81Y
81Z
113.40
113.45
−
−
5067.6
5067.9
−
622
623
1105
1105
1105
12
36
−
−
36
21
−
42
27
1168
1042
1042
12
30
15
82X
82Y
82Z
113.50
113.55
−
−
5068.2
5068.5
−
624
625
1106
1106
1106
12
36
−
−
36
21
−
42
27
1169
1043
1043
12
30
15
83X
83Y
83Z
113.60
113.65
−
−
5068.8
5069.1
−
626
627
1107
1107
1107
12
36
−
−
36
21
−
42
27
1170
1044
1044
12
30
15
84X
84Y
84Z
113.70
113.75
−
−
5069.4
5069.7
−
628
629
1108
1108
1108
12
36
−
−
36
21
−
42
27
1171
1045
1045
12
30
15
85X
85Y
85Z
113,80
113,85
5070.0
5071.3
1109
1109
1109
12
36
36
21
42
27
1172
1046
1046
12
30
15
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-9
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table 1-2. Frequencies and Code Pulses for DME Channels (86 to 99)
DME PARAMETERS
CHANNEL PAIRING
INTERROGATION
REPLY
Pulse Codes
DME/P
DME
Channel
VHF
FREQ.
MHz
MLS
FREQ.
MHz
MLS
Channel
Frequency
MHz
DME/N
µs
IAM
µs
FAM
µs
Frequency
MHz
Pulse
Codes
µs
86X
86Y
86Z
113.90
113.95
−
−
5070.6
5070.9
−
632
633
1110
1110
1110
12
36
−
−
36
21
−
42
27
1173
1047
1047
12
30
15
87X
87Y
87Z
114.00
114.05
−
−
5071.2
5071.5
−
634
635
1111
1111
1111
12
36
−
−
36
21
−
42
27
1174
1048
1048
12
30
15
88X
88Y
88Z
114.10
114.15
−
−
5071.8
5072.1
−
636
637
1112
1112
1112
12
36
−
−
36
21
−
42
27
1175
1049
1049
12
30
15
89X
89Y
89Z
114.20
114.25
−
−
5072.4
5072.7
−
638
639
1113
1113
1113
12
36
−
−
36
21
−
42
27
1176
1050
1050
12
30
15
90X
90Y
90Z
114.30
114.35
−
−
5073.0
5073.3
−
640
641
1114
1114
1114
12
36
−
−
36
21
−
42
27
1177
1051
1051
12
30
15
91X
91Y
91Z
114.40
114.45
−
−
5073.6
5073.9
−
642
643
1115
1115
1115
12
36
−
−
36
21
−
42
27
1178
1052
1052
12
30
15
92X
92Y
92Z
114.50
114.55
−
−
5074.2
5074.5
−
644
645
1116
1116
1116
12
36
−
−
36
21
−
42
27
1179
1053
1053
12
30
15
93X
93Y
93Z
114.60
114.65
−
−
5074.8
5075.1
−
646
647
1117
1117
1117
12
36
−
−
36
21
−
42
27
1180
1054
1054
12
30
15
94X
94Y
94Z
114.70
114.75
−
−
5075.4
5075.7
−
648
649
1118
1118
1118
12
36
−
−
36
21
−
42
27
1181
1055
1055
12
30
15
95X
95Y
95Z
114.80
114.85
−
−
5076.0
5076.3
−
650
651
1119
1119
1119
12
36
−
−
36
21
−
42
27
1182
1056
1056
12
30
15
96X
96Y
96Z
114.90
114.95
−
−
5076.6
5076.9
−
652
653
1120
1120
1120
12
36
−
−
36
21
−
42
27
1183
1057
1057
12
30
15
97X
97Y
97Z
115.00
115.05
−
−
5077.2
5077.5
−
654
655
1121
1121
1121
12
36
−
−
36
21
−
42
27
1184
1058
1058
12
30
15
98X
98Y
98Z
115.10
115.15
−
−
5077.8
5078.1
−
656
657
1122
1122
1122
12
36
−
−
36
21
−
42
27
1185
1059
1059
12
30
15
99X
99Y
99Z
115.20
115.25
−
−
5078.4
5078.7
−
658
659
1123
1123
1123
12
36
−
−
36
21
−
42
27
1186
1060
1060
12
30
15
1-10
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table 1-2. Frequencies and Code Pulses for DME Channels (100 to 113)
DME PARAMETERS
CHANNEL PAIRING
INTERROGATION
REPLY
Pulse Codes
DME/P
DME
Channel
VHF
FREQ.
MHz
MLS
FREQ.
MHz
MLS
Channel
Frequency
MHz
DME/N
µs
IAM
µs
FAM
µs
Frequency
MHz
Pulse
Codes
µs
100X
100Y
100Z
115.30
115.35
−
−
5079.0
5079.3
−
660
661
1124
1124
1124
12
36
−
−
36
21
−
42
27
1187
1061
1061
12
30
15
101X
101Y
101Z
115.40
115.45
−
−
5079.6
5079.9
−
662
663
1125
1125
1125
12
36
−
−
36
21
−
42
27
1188
1062
1062
12
30
15
102X
102Y
102Z
115.50
115.55
−
−
5080.2
5080.5
−
664
665
1126
1126
1126
12
36
−
−
36
21
−
42
27
1189
1063
1063
12
30
15
103X
103Y
103Z
115.60
115.65
−
−
5080.8
5081.1
−
666
667
1127
1127
1127
12
36
−
−
36
21
−
42
27
1190
1064
1064
12
30
15
104X
104Y
104Z
115.70
115.75
−
−
5081.4
5081.7
−
668
669
1128
1128
1128
12
36
−
−
36
21
−
42
27
1191
1065
1065
12
30
15
105X
105Y
105Z
115.80
115.85
−
−
5082.0
5082.3
−
670
671
1129
1129
1129
12
36
−
−
36
21
−
42
27
1192
1066
1066
12
30
15
106X
106Y
106Z
115.90
115.95
−
−
5082.6
5082.9
−
672
673
1130
1130
1130
12
36
−
−
36
21
−
42
27
1193
1067
1067
12
30
15
107X
107Y
107Z
116.00
116.05
−
−
5083.2
5083.5
−
674
675
1131
1131
1131
12
36
−
−
36
21
−
42
27
1194
1068
1068
12
30
15
108X
108Y
108Z
116.10
116.15
−
−
5083.8
5084.1
−
676
677
1132
1132
1132
12
36
−
−
36
21
−
42
27
1195
1069
1069
12
30
15
109X
109Y
109Z
116.20
116.25
−
−
5084.4
5084.7
−
678
679
1133
1133
1133
12
36
−
−
36
21
−
42
27
1196
1070
1070
12
30
15
110X
110Y
110Z
116.30
116.35
−
−
5085.0
5085.3
−
680
681
1134
1134
1134
12
36
−
−
36
21
−
42
27
1197
1071
1071
12
30
15
111X
111Y
111Z
116.40
116.45
−
−
5085.6
5085.9
−
682
683
1135
1135
1135
12
36
−
−
36
21
−
42
27
1198
1072
1072
12
30
15
112X
112Y
112Z
116.50
116.55
−
−
5086.2
5086.5
−
684
685
1136
1136
1136
12
36
−
−
36
21
−
42
27
1199
1073
1073
12
30
15
113X
113Y
113Z
116.60
116.65
−
−
5086.8
5087.1
−
686
687
1137
1137
1137
12
36
−
−
36
21
−
42
27
1200
1074
1074
12
30
15
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-11
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table 1-2. Frequencies and Code Pulses for DME Channels (114 to 126)
DME PARAMETERS
CHANNEL PAIRING
INTERROGATION
REPLY
Pulse Codes
DME/P
DME
Channel
VHF
FREQ.
MHz
MLS
FREQ.
MHz
MLS
Channel
Frequency
MHz
DME/N
µs
IAM
µs
FAM
µs
Frequency
MHz
Pulse
Codes
µs
114X
114Y
114Z
116.70
116.75
−
−
5087.4
5087.7
−
688
689
1138
1138
1138
12
36
−
−
36
21
−
42
27
1201
1075
1075
12
30
15
115X
115Y
115Z
116.80
116.85
−
−
5088.0
5088.3
−
690
691
1139
1139
1139
12
36
−
−
36
21
−
42
27
1202
1076
1076
12
30
15
116X
116Y
116Z
116.90
116.95
−
−
5088.6
5088.9
−
692
693
1140
1140
1140
12
36
−
−
36
21
−
42
27
1203
1077
1077
12
30
15
117X
117Y
117Z
117.00
117.05
−
−
5089.2
5089.5
−
694
695
1141
1141
1141
12
36
−
−
36
21
−
42
27
1204
1078
1078
12
30
15
118X
118Y
118Z
117.10
117.15
−
−
5089.8
5090.1
−
696
697
1142
1142
1142
12
36
−
−
36
21
−
42
27
1205
1079
1079
12
30
15
119X
119Y
119Z
117.20
117.25
−
−
5090.4
5090.7
−
698
699
1143
1143
1143
12
36
−
−
36
21
−
42
27
1206
1080
1080
12
30
15
120X
120Y
117.30
117.35
−
−
−
−
1144
1144
12
36
−
−
−
−
1207
1081
12
30
121X
121Y
117.40
117.45
−
−
−
−
1145
1145
12
36
−
−
−
−
1208
1082
12
30
122X
122Y
117.50
117.55
−
−
−
−
1146
1146
12
36
−
−
−
−
1209
1083
12
30
123X
123Y
117.60
117.65
−
−
−
−
1147
1147
12
36
−
−
−
−
1210
1084
12
30
124X
124Y
117.70
117.75
−
−
−
−
1148
1148
12
36
−
−
−
−
1211
1085
12
30
125X
125Y
117.80
117.85
−
−
−
−
1149
1149
12
36
−
−
−
−
1212
1086
12
30
126X
126Y
117.90
117.95
−
−
−
−
1150
1150
12
36
−
−
−
−
1213
1087
12
30
1-12
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
1.3
955 900 031C
GENERAL FEATURES OF THE EQUIPMENT
1.3.1
Equipment Versions
The DME 415 and 435 are respectively the lower power and the higher power versions of a complete
family of latest-generation equipment composed by:
Approach DME 415: a 100 W solid-state DME can be installed also in co-location with ILS
En-route DME 435: a 1 kW solid-state DME can be installed also in co-location with VOR or DVOR.
The two versions all feature a high commonality of modules and of principles of operation.
1.3.2
Main Feature of the Equipment
The main features of the equipment are:
•
Compliant with the ICAO specifications in Annex 10, 5th ed. and Eurocae MPS Ed. 57, standard 1 as
applicable.
•
Compliant with EEC Directives for CE Marking (EMC and Safety)
•
Housed in a single 19" cabinet
•
Powerable both from mains and standard 48 V batteries, with a built-in battery charger as an option
•
Fully dualized, (being composed of two transponders and two monitoring systems ) but configurable
also in the following versions:
1) single TRX and single Monitor
2) single TRX and dual Monitor
•
Completely modular
•
Accurate distance information: up to ±15 m
•
Digitally controlled output pulse shape
•
Microprocessor-controlled monitors and transponders
•
Monitor-independent reply delay self-adjustment
•
Automatically performed self-check and measurements, the results of which can be continuously
displayed
•
Automatically provided ICAO performance checks at programmable intervals and results
storing/displaying/printing
Capable of executing a resident diagnostic program to help the operator in fault location.
•
•
Operable as a stand-alone unit, but conceived to be co-located with other navaids like ILS,VOR or
DVOR
•
Control by a Personal Computer (PC) at beacon site, which can be duplicated at remote site; the PC
can also be a portable unit to be connected only when required for maintenance reasons
•
Remote control is fully compatible with all the system 400 equipment and with previous versions of
DME’s (FSD-40/45)
•
Able to be connected to both an RCSU-2040 (part of Thales: Remote Maintenance and Monitoring
Configuration - RMMC) and the FRCM/NS Remote Control and Monitoring Network System, or new
remote control MCS (Monitoring and Control System): highly versatile systems for interfacing and
controlling different navaids facilities.
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-13
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
1.3.2.1
Engineering
•
Accessibility: front door access is only required. Equipment can be wall-mounted.
•
Modularity: all circuits are divided into functional modules.
•
Interconnections: extensive use is made of printed board back panels, flat ribbon cables and semi-rigid
coaxial cables.
•
Identifications: all modules are easily recognizable by P/N and a two/three/four-letter code (e.g.: RX,
TX, DPR, BCPS) permanently marked on easily readable surfaces. All modules, cables and connectors
are marked and keyed to prevent incorrect connection.
•
Cooling: no blowers are required to remove heat from the equipment. Use is made of extruded
aluminum heat sinks.
•
Printed boards: two - or multilayer printed boards with plated-through holes are used throughout the
equipment. High frequency circuits are implemented in microstrip technique.
•
RF shielding: all RF circuits are accurately shielded in casting boxes.
•
Components: only high-quality components are used, in order to meet the reliability requirements.
•
Corrosion: protection against corrosion and fungus is obtained by means of suitable materials, finishes
and coatings.
1.3.2.2
Safety
• The equipment is designed to be intrinsically safe for the user. No dangerous voltages except mains are
used.
•
All modules or places, where a dangerous voltage may be accessible, are firmly protected by covers not
removable without using tools and are clearly marked with warning readouts.
• Special protective circuits are built-in in order to ensure that any failure in the equipment does not cause
further damage to other parts or components.
1.3.2.3
Installation
• Installation of DME 415-435 requires preparation of the site (i.e. shelter or equipment room, antenna
support mast, cable layout, power and ground connections etc.- (see section 2 "INSTALLATION" and
ANNEX A "DME ANTENNA SITING CRITERIA" in this manual).
• Installation of the equipment is simple and can be accomplished in few hours even by unskilled personnel
with a minimum of tools. The equipment only requires a minimum of shelter room.
• Ground and flight tests may be performed with the assistance of Thales technicians if requested.
1.3.2.4
Operation
• The Operator's interface consists of a PC terminal connected to the equipment. The basic control of the
equipment (on/off or changeover) is possible with local I/O front panel, however, even when the PC is not
available,
1-14
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Cabinet Part Number: 297.509.004
Cabinet Part Number: 297.509.007
Figure 1.4. DME 415 (same as DME 435) – Cabinet and PC, example of arrangement
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-15
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
1.4
BEACON COMPOSITION AND IDENTIFICATION
The DME 415/435 ground equipment, as shown in figure 1.4, is constructed by THALES Italia S.p.A Air
Systems Division - Milan - Italy.
The DME versions are mounted in two cabinet’s types shown in figure 1.4 to customer choice.
The related reference modules labels of the equipment DME415/435 are given in table 1-3.
Table 1-3. Composition of the Equipment
Dual
Single
Q.ty
Name
Ref.
Label
Wired Cabinet (standard)
RF Path
Duplexer
DPX
RF COAX Relay and PBA
KCX
Coax Dummy Load -100 W, 50 Ω
2+2
1+1
External Filter Antenna KIT (optional)
10 dB + 10 dB PAD ( only for DME 435)
Interface System
Associated Facility Interface
AFI
Dummy Interface
TAI
Modem 1 Party Line (LGM 1200) (option)
MDM
Modem 2 LGM 28,8 D1 (option)
MDM
Transponder and Monitor
Power Supply (DC/DC converter; + 5V, ± 15V )
PWS
Monitor
MON
Receiver
Digital Processor
DPR
Digital Modulator
DMD
Transmitter 100 Wp (also driver for DME 435)
TX 100
Transmitter Amplifier 1kWp (only for DME 435)
TKW
RX
Local I/O
Local Control Status Unit composed of:
- Control and Status Board
- Indication and Controls
LCSU
CSB
INC
Power Supply
1-16
Battery Charger and Power Supply subrack (option)
BCPS
AC/DC 600W Module (option)
AC-DC
Terminal bar- 48Vdc (option)
Batteries supervisor only for BCPS Frako (option)
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table 1-4 gives the composition of the user interface for the local and remote sites.
The accompanying material supplied with the beacon is listed in table 1-5.
Table 1-4. User Interface Composition (option)
Q.TY
NAME
REF.
PC Requirements- Lap/Palm top
Processor Pentium 90 or better, (for use with MCS monitoring:
INTELP4, AMDK7 - Clock speed 2 GHz or better )
Operating system IBM/AT compatible suited to run 95, 98, 2000XP or
NT version (for MCS: WIN/NT, W2K, Linux)
Main memory 16 MB RAM min. (256/512 MB min for MCS)
VGA adapter color display: 32MB
HDD: 120 MB min. Hard Disk, min. 20MB free space on HDD
( 20GB/2x20GB min for MCS)
3.5” Floppy Disk FDD (1.44 MB),
CDROM drive,
Control via mouse or comparable
Serial interface connectors
Printer
Status Indicator (repeater of the main indication beacon status)
LOCAL SITE:
SI 446
REMOTE SITE:
Remote Control Status Indicator (composition: see RCSI or RCSE or MCS
technical manual)
PC Requirements- Lap/Palm top: as Local site
Keyboard (PC desk version)
Printer
Status Indicator (repeater of the main indication beacon status)
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
RCSI 446
SI 446
1-17
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Table 1-5. Material Supplied
Name
NOTE
STANDARD
PC interconnection cable
OPTIONAL
Mains Cable
Grounding Cable
Battery Cable (+)
Battery Cable (-)
Auxiliary INPUT Cable (Parallel I/O)
Auxiliary OUTPUT Cable (Parallel I/O)
Cable for external modem
Interface Facility Cable (for AFI interface
module)
Serial data Cable (D-VOR/ILS)
Telephone Cable
Antenna coax cable
Antenna monitors probe coax cables
Obstruction light cable
Modem adapter Kit
Tool bag
Extender board - Video Digital (see Vol. 2
Section 1)
Extender board - RF (see Vol. 2 Section 1)
Figure 1.4 is a typical example of arrangement of the equipment and shows the front of a door. The local
indication and control panel is flush-mounted in the front door. It contains an RS232 connector for
interfacing with an intelligent terminal (PC).
Figures from 1.5 to 1.9 show the location of the parts and modules of the equipment valid for both cabinet
type.
Figure 1.8 shows the photos of DME 435 with front door closed and rear of equipment.
Each equipment module and part code number is indicated on Vol. 2: List of Components in this Technical
Manual.
1-18
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
1.5
955 900 031C
PHYSICAL AND MECHANICAL General Description
The standard (full dual) configuration of the DME 415-435 equipment is composed of two transponders, a
dual monitor system a RF path system, a Panel Control and a coaxial transfer relay unit. The parts of the
equipment are housed in a single 19" standard cabinet (cabinet’s types: view in fig. 1.4).
The cabinet, which is made of molded and welded steel sheet, can accommodate four 19” assembled
carriers (subracks). Plug-in units are used as double or single Euroform printed circuit boards, with
dimensions of 233.4 x 220 [mm] or 100 x 220 [mm].
The cabinet, which has a perforated metal plate on top and bottom, is self-ventilated (no forced ventilation
necessary).
NOTE: Do not block or seal the holes for the cooling air supply.
The front part of the cabinet is protected by a hinged door complete of locking mechanism and the Control
front Panel (Local I/O).
The top end of the cabinet provides four threaded holes used to screw in the eyebolts when the beacon is to
be lifted.
The RF output connector to the antenna and the RF antenna monitor input connectors are located on top of
the cabinet. The RF Duplexer modules are mounted inside of the "RF Amplifier/DPX" subrack on the upper
part of the cabinet. The 1 kWp RF amplifier modules are mounted on the lateral sides of the same subrack,
while the interface connections (e.g. modem, Associated Facility) are located on the bottom.
The RF components of the modules are in shielded casting boxes.
The Transponder/Monitor 1 and 2 subracks are located in middle part of the cabinet.
The AC/DC power supply units are located on the bottom of the cabinet. The BCPS subrack (optional)
comprises a terminal bar for mains and 48Vdc input.
Local I/O components (LCSU consisting of CSB module and INC module) are fastened to the hinged front
door in the upper part. The CSB board of the LCSU unit, combined with the INC module, is mounted on the
rear of the front door.
The local control front panel of the INC module part of LCSU unit is equipped with indicators and
commands:
−
the indicators, for immediate check of beacon functioning and
−
the main commands, for beacon control (acquisition and release of control, powering on/off,
transponder change over) without having to use the local PC.
The I/O panel with the external interconnection connectors is located in the top end of the cabinet (figure
1.9)
The front view of the DME 415 and DME 435 equipments, with the open door, is shown in figures 1.5 and
1.6. These figures show the positions of all the modules, which compose the equipment in the typical full (or
dual) version.
For special purposes, the equipment can be supplied in a single, non-redundant version, where very high
system availability is not mandatory.
Figure 1.7 shows the typical single version of the DME 435 equipment. The single version of the DME 415 is
the same as the DME 435 in which the final RF amplifier "TKW" module is removed.
The DME 415-435, dual or full version, is composed of a wired cabinet housing the following hardware parts
and modules:
‰
Local I/O
• Local Control and Status Unit
− Control Status Board module
− Indication and Control module
• I/O Panel (on top of the cabinet)
Vers. D, September 2005
(LCSU) composed of
(CSB)
(INC)
THALES Italia S.p.A.- A. S. D.
1-19
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
‰
RF Amplifier/DPX subrack unit consisting of:
•
•
•
•
•
•
•
•
‰
(TKW)
(DPX)
(KCX and KCXM)
(AFI)
(TAI dummy)
(MDM) ( including adapter kit : RS232 to TTL converter)
(BPKW)
Transponder/Monitor 1 and 2 subrack units, both consisting of:
•
•
•
•
•
•
•
‰
Final Amplifier module (DME 435 only)
Duplexer module
Coaxial Relay and driver PBA
Coax Dummy Load
Association Facility Interface module
Interface
Modem modules (optional)
Backpanel of the TKW
DC/DC Power Supply module
Monitor/Interrogator module
Receiver module
Processor module
Modulator module
Transmitter (driver for DME 435)
Backpanel of the transponder/monitor
(PWS)
(MON)
(RX)
(DPR)
(DMD)
(TX100)
(BPT)
Mains Power unit
•
•
•
Battery Charger Power Supply subrack
AC/DC module
Terminal Bar
(BCPS)
(AC/DC)
All check and maintenance operations can be performed on the front of the equipment, upon opening the
cabinet front door.
Each subrack can be pulled out after unscrewing the fixing bolts (sliding are not provided).
All main modules (except the front ones of the LCSU unit) are plug-in types. Each module slides can be
easily pulled out by using proper handles placed on the front.
The bottom of the cabinet provides the entrance of the mains and 48 V dc cables through bush fair-leads
(see Section 2: INSTALLATION).
Connectors of the I/O panel mounted on the upper side of the cabinet provide the connection with the
external interface cables.
Each subrack has a backpanel on which connectors of the plug-in modules and the subrack interconnection
are mounted. All cable connectors (signals and mains) of subrack interconnection are within reach from the
front.
Interconnection with backpanels is provided by flat ribbon cables for low level signals and by cables for
48Vdc supply. Cables lay on the inside of the cabinet behind the subracks.
A 4-way (transfer type) RF coaxial relay is mounted on a support fixed on the upper side of the cabinet by
means of bolts (Figure 1.9), which can be unscrewed before inspecting the relay. The relay RF output is
directly connected to the antenna connector. The relay is power supplied through a specific interface circuit
fixed on the same coaxial relay.
The RF connection semi-rigid coaxial cables lay on the inside of the cabinet behind the subracks.
The semi-rigid coaxial cables end with floating coaxial connectors used for the sliding modules that also
comprise the RF circuits. The floating coaxial connectors are mounted on a reinforcement metal plate fixed
on the back of the back panels.
The coaxial cables used for the output RF power provide the minimum distance and end with type "N"
coaxial connectors.
1-20
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Connettori per Sonde
Monitori d'Antenna
CONNETTORE
d'Antenna
n° 4 Golfari
LCSU unit
Vista retro
C arico Fittizio
50 O hm
RELE'
COAX
OUT
DPX 2
DPX 1
OUT
TKW 1
IN
TKW 2
IN
SUBRACK
RF AMPL/DPX
MDM 1(option)
AFI
N.U.
PANELLO RF
di TEST
MDM 2 (option)
SUBRACK
TRX/MON (1)
TX 2
DPR 2
DMD 2
J1
TX 1
DPR 1
DMD 1
RX 1
RX 2
PWS 2
J1
MON 1
Contenitore di Documenti
MON 2
PWS 1
N.U.
SUBRACK
TRX/MON (2)
IN
48Vdc MAINS
54 Vdc OUT
Barra Terminale
Module OK
V adj
Module OK
TP
Mains OK
AC/DC 1
V adj
TP
Mains OK
AC/DC 2
Subrack BCPS
Figure 1.5. DME 435 – Front view with anterior door opened – Full Dual version
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-21
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
ANTENNA MONITORS PROBES
CONNECTORS
ANTENNA
CONNECTOR
Nr. 4 eyebolts
for to be lifting
50 Ohm
Dummy Load
LCSU unit
Rear view
OUT
OUT
DPX 1
DPX 2
COAX
RELAY
IN
IN
RF AMPL/DPX
SUBRACK
RF TEST
PATCH PANEL
AFI
MDM 2 (opzion.)
MDM 1(opzion.)
N.U.
RX 2
TRX/MON (1)
SUBRACK
TX 1
TX 2
J1
DMD 2
DMD 1
DPR 1
RX 1
MON 1
PWS 2
J1
MON 2
Documents holder
DPR 2
PWS 1
N.U.
TRX/MON (2)
SUBRACK
Terminal BAR
Module OK
V adj
Modul e OK
TP
Mains OK
AC/DC 1
V adj
TP
Mains OK
AC/DC 2
BCPS Subrack
Figure 1.6. DME 415 – Front view with anterior door opened – Full Dual version
1-22
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
ANTENNA
CONNECTOR
ANTENNA MONITORS PROBES
CONNECTORS
LCSU unit
Rear view
Nr. 4 eyebolts
for to be lifting
50 Ohm
Dummy Load
COAX
RELAY
OUT
DPX
TKW
RF TEST
PATCH PANEL
IN
RF AMPL/DPX
SUBRACK
MDM 1(option)
AFI
N.U.
MDM 2 (option)
TRX/MON (1)
SUBRACK
TX
DPR
DMD
J1
RX
Documents holder
MON
PWS
N.U.
J1
IN
48Vdc MAINS
54 Vdc OUT
Terminal BAR
Module OK
V adj
TP
Mains OK
AC/DC
BCPS Subrack
Figure 1.7. DME 435 Single version – Front view with anterior door opened
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-23
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Figure 1.8. DME 435 – Rear side view of the cabinet
NOTE: Rear view valid for both cabinets type
1-24
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
NOTE: Top end valid for both cabinets type
N° 4 eyebolts
Rear
I/O PANEL
PL1
SK1
PORT 3 (DCE/DTE)
PORT 1 (DCE)
SK3
SK2
OUT(16/31)
OUT(0/15)
SK4
AF1
PC (RS232)
PL2
PL3
PORT 2 (DTE)
IN (0/15)
SERIAL PORT (RS232)
PL4
IN (16/31)
PARALLEL PORT
SK5
AF2
ASSOC. FACILITY
SK6
TACAN ANTENNA
PL7
1-6= LINE 1
3-8=LINE 2
TEL. LINES
M1
M2
ANTENNA CONNECTOR
"N" type Female
ANTENNA MONITORS
CONNECTORS
"N" type Female
NOT to SCALE
AIRING GRID
Front
Figure 1.9. DME 415/435 – Top view
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-25
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
1.6
EQUIPMENT FUNCTIONAL DESCRIPTION
1.6.1
General Overview
The DME 415/435 system consists of hardware based on RF and video PBA, and of software that
largely controls the hardware. In order to explain these functions, the description is divided in following
main parts as by composition of the equipment (see also the simplified general block schematic with
the main RF signals on fig 1.10.
The system is subdivided into the following units (dual or single version):
- Transponder (RX, DPR, DMD, TX-100, PWS)
- Transmitter Amplifier 1kWp (TKW) (only for DME 435)
- RF path – Duplexer and Coax. Relay (DPX, KCX, MKCX and TAI dummy)
- Monitor (MON)
- Local I/O (LCSU)
- Associated Facility Interface (AFI)
- AC/DC Power supply (BCPS)
- Antenna
- Modem (optional)
- Remote Control Indication (RCSI/RCSE or MCS)
Transmitter and monitor are controlled by their own individual microprocessors. Both communicate with the
LCSU, controlled by its own microprocessor.
The transponder processor performs the following main tasks:
General management of the transponder
Digital and video processing
Control/adjustment of main delay
Control/adjustment of modulation for peak power and pulse shape
The monitor processor performs the following main tasks:
General management of the monitor
RF signal generation of interrogation pair for executive monitoring
Evaluation of the transponder reply signals and receiver sensitivity (in Antenna and Dummy load)
Execution of appropriate actions in case of fault detection (station changeover or shutdown)
Ensuring of its own performance independent of environmental conditions and component
aging (selfcheck)
The software packages (i.e., transponder SW, monitor SW, LCSU SW, PC WIN Supervisor, WIN ADRACS
or MCS and WIN EQUIPMENT MANAGER) looks after and supports the most important tasks as follows:
- Startup (alignment and calibration of the set up)
- Modulation and transmitter control
- Signal generation
- Monitoring the output signal of the transponder
- Support in system repair and maintenance
- Operation of the system (local/remote)
1-26
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
The Local I/O (LCSU) processor performs the following main tasks:
Communication via serial line RS232 with the monitor(s) and via serial line RS485 with transponders
Beacon-operator interface via Personal Computer
Basic beacon-operator interface via the Control Panel front door
Check of the settings of equipment
Connection to one or more remote control centers through switched or dedicated telephone lines
Communication via modem with remote monitoring and site control
History management
The Duplexer and RF path performs the following main tasks:
Exchanges the RF path of the main transponder and of the stand-by transponder on the antenna and on
the internal dummy load
Coupling signal for monitoring interrogation
Coupling signal for Pilot pulse
Manual RF test with patch panel
1.6.2
DME 415/435 System Functional Description
The beacon comprises the following main parts:
− I/O system (LCSU, RCSI/RCSE or MCS, SI, PC, MDM);
− Transponder (RX, DPR, DMD, TX100, PWS);
− 1kWp Amplifier (TKW only DME435)
− RF path (DPX, Patch-panel);
− Monitoring (MON);
− Interface (AFI) and (TAI dummy);
− AC/DC power supply (BCPS).
− DME Antenna
The beacon can also be configured as single transponder either with one or two monitor(s).
The simplified functional block diagram of the dual configuration is shown in figure 1.10.
The simplified functional block diagram of the main RF signal path is shown in figure 1.11
A coaxial transfer switch (controlled by Monitors) is used to the transponder(s) either with the antenna line
(main transponder) or with the internal dummy load (stand-by transponder) (see figure 1.10).
The antenna probes are used to monitoring the reply RF signals (figures 1.10 and 1.11)
Figures 1.12 and 1.13 are simplified functional block diagrams of the I/O and power supply systems
respectively.
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-27
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
1-28
RF Interrog./Reply
pair pulses
X Mode
ANTENNA
MONITOR
PROBES
Pilot Pulse
Y Mode
RF Reply pulses
for monitoring
RF Interrogation pulses
for monitoring
Transponder 1 (TRX-1)
DPX-1
RX
Transponder 2 (TRX-2)
DPX-2
COAX
RELAY
17dB
coupler
TX
ADDER/DIVIDER
5V, ±15V
TX
20 dB
coupler
RX
ADDER/DIVIDER
5V, ±15V
RS-485
RS-485
DC/DC
Power Supply
DC/DC
Power Supply
PWS-1
PWS-2
ch-over
Monitor
5V, ±15V
5V
to LCSU
MON-1
Monitor
MON-2
status
5V
to LCSU
RS-485
RS 232
+48
Vdc
RS 232
to/from
TRX1
TRX2
Assoc. Facility
Local I/O
LCSU
Local PC
REMOTE
control unit /PC
AFI
+48
Vdc
to Associated
Facility
Battery Charger
AC/DC Power Supply
BCPS
MAINS
BATT.
Figure 1.10. DME 415/435 – Simplified general block diagram
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-28
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
INTERCONNECTING COAX CABLES
MONITOR SWITCHES POSITION
SWITCH
S1
S2
S3
S4
S5
Interrog. for CALIB.
Interrog. to RX1/2
REPLY from TX1/2
A/B
A/B
ANTENNA Monit. PROBE
DIAGNOSTIC
INTERCONNECTING COAX CABLES
ANT
W1=Antenna (Ext)
W2=Antenna Probes (Ext)
W3=TX to DPX
W3a=TKW to DPX (DME435)
W3b=TX to TKW (DME435)
W4=RX to TX
W5a=DPX to RX via Patch Panel
W5b=RX to DPX via Patch Panel
21 dB
"N"
W6=DPX to KCX
W7a=RX test via Patch Panel
W7b=RX test via Patch Panel
W8a=MON Interr/Reply via Patch Panel
W8b=MON Interr/Reply via Patch Panel
W9=MON Interr/Reply (Cross interconnecting)
W10=Antenna Probes
21 dB
"N"
W2
W1
"N"
W2
BPF
(opt)
DME 415/435
"N"
10
dB
17dB
20 dB
"N"
LRXINHD1
"N"
dB
"N"
W5a
dB
dB
W3a
"SM A"
10
dB
RX IN
(SEE NOT E)
W8a
MON I/O
W9
W9
W9
W9
" SMA"
"SMA"
MON I/O
" S M A"
10
dB
( S E E N O TE )
W8b
W8b
TKW1
RX 1
S2
AA
20 dB
MON 2
BB
S2
S2
S3
BB
63 MHz
SYNTH.
VCO
BB
SYNTH.
VCO
A S5
59 MHz
W4
DET
MEASUREM. DET-A
S1
MH z
W3b
SYNTH.
S4
IF
17dB
20 dB
63 MHz
W3b
TX 1
TKW2
RX 2
63
S1
"N"
S3
63 MHz
AA
W3
W5b
W7b
MON 1
17dB
W3a
RX IN
" SMA"
W7b
"N"
W5a
W7a
RF PATCH PANEL 2
" SMA"
W5b
"N"
Pilot Pulse
"S M A "
W3
LRXINHM2
W10
RF PATCH PANEL 1
" S M A"
LRXINHD2
13
dB
dB
W10
W8a
17
dB
KCXM
50 ohm
Dummy
Load
20 dB
10
dB
"N"
Pilot Pulse
W7a
DP X- 2
17dB
Transfer
coax relay
"N"
13
dB
LRXINHM1
"N"
W6
10
dB
N OT E )
"TNC"
"N"
W6
17
dB
( SEE
KCX
"TNC"
DPX 1
1, 2, 3, 4 = DPX
1, 2, 3 = RX, MON
1, 2,
= TX
"TNC"
"TNC"
10
dB
( S EE N OT E )
NOTE: 10 dB Attenuators used when TKW is present
"N"
"N"
PLUG-IN Type COAX CONNECTOR
Module REF POSITION
VCO
S4
TX 1
IF
S5
Reply Measur. and
Diagnostic
Purpose
DET-A
SYNTH.
VCO
DET
MEASUREM.
59 MHz
W4
ED.: 1 - 1999
1-29
Figure 1.11. DME 415/435 – Main RF path signals - General simplified block diagram
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-29
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
TELEPH. LINE
(PC Remote or RCSI)
STATUS SITE
INDICATION
ESD
protection
(option)
MODEM 1
LCSU unit
(CSB module)
CONTROL
PANEL &
STA TUS IND.
RS232
SERIAL
COM MUNICAT.
DRIVER
RECE IVER
CONTROLLER
INC module
PC
RS232
DRIVER
RECE IVER
PARALLEL
SERIAL
COM MUNICAT.
I/O
CONTROLLER
SERIA L
AUXILIARY ON/OFF
Controls and Indications
COM MUNICAT.
CONTROLLER
RS232
RS232
DRIVER
RECE IVER
PRINTER
RS485
Asyncro Conv. Interf.
DRIVER
RECE IVE R
RS422
SI446
CPU
RS232
RS232
DRIVER
RECEIVE R
DRIVER
RECEIVE R
MODEM 2
+5 V
RS 232
Seial Line
RS 232
Seial Line
MON1
MON2
ESD
protection
(option)
RS 485
Seial Line
TELEPH. LINE
(PC Remote or RCSI)
TRX1
TRX2
TRANSPONDERS Communication
Figure 1.12. DME 415/435 – Local I/O system general block diagram
MAINS
48V to
transponder/monitor 1
BREAKERS on external Electrical Switchboard (recommended)
Fuse 10A
AC/DC 1
600 W/10A
Fuse 2A
48V to
service purpose
*)
*)
Fuse 10A
AC/DC 2
600 W/10A
BATT.
Typical
50A/h-48V
External BATT RELAY
SWITCH (Optional)
48V to
transponder/monitor 2
Command ON/OFF (N.U.)
(From LCSU)
ACFTY1
ACFTY2
MAINS1
MAINS2
BPDPL
INDICATIONS
(To LCSU)
Figure 1.13. DME 415/435 – AC/DC Power Supply system & Battery Charge - Block diagram
1-30
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
1.6.3
955 900 031C
I/O SYSTEM - Functional description
Consist of the Local and Remote Control & Maintenance System.
The I/O system is totally modular; it is able to meet any type of requirement that may arise in an installation.
Main features of the System are:
• Control/monitoring of the equipment by means of a standard Personal Computer, and/or Remote Control
& Status Indicator and/or a Status Indicator of the beacon main indication.
• Control and monitoring of the beacon and its associated equipment (only on customer request), if any
(e.g. VOR/ILS), by using a Personal Computer.
• Possibility to control, monitor and maintain the equipment station by using the public switched network
or dedicated telephone lines
It is composed by the following main parts:
–
Local Control & Status Unit "LCSU" housed inside the equipment, consisting of the Control Status
Board module (CSB), the Indication and Control module (INC) and I/O panel
–
Remote Control & Status Indicator "RCSI 446, RCSE 443 or MCS" (optional).
–
Status Indicator "SI 446" (optional).
–
standard Personal Computer IBM compatible (optional).
–
Modem (optional).
1.6.3.1
I/O Local site
At the local site, the beacon-operator interface consists of:
− Module INC (LCSU) control and indication front panel;
− Personal Computer (optional), which allows the operator to completely control and monitor the beacon;
− Status Indicator SI446 (optional), which may be installed in the equipment control room or control
tower.
It is handled by the LCSU unit, which also controls the communication with other equipment and/or
device(s), through RS-232C serial interface ports or through modem and telephone lines.
− The I/O Panel (figure 1.14) located on the top end of the cabinet is complete with a set of
interconnection connectors interface the external equipment or devices.
A typical configuration of the local site set-up is shown in figure 1.15.
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-31
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
1-32
PL1
SK1
PORT 3 (DCE/DTE)
PORT 1 (DCE)
SK3
SK2
OUT(0/15)
OUT(16/31)
PC (RS232)
PL2
PL3
PORT 2 (DTE)
IN (0/15)
PARALLEL PORT
SERIAL PORT (RS232)
PL1 = UNAVAILABLE if MDM 2 IS USED
PL2 = UNAVAILABLE if MDM 1 IS USED
PL4
SK1 = PC connection
UNAVAILABLE if
PC connector on
FRONT PANEL
is USED
IN (16/31)
SK6
SK4
AF1
TACAN ANTENNA
PL7
SK5
AF2
1-6= LINE 1
ASSOC. FACILITY
SK2 = N° 16 AUXILIARY ON/OFF OUT SIGNALS (standard) SK4 = Associated Facility EQPT 1
SK5 = Associated Facility EQPT 2
PL3 = N° 16 AUXILIARY ON/OFF IN SIGNALS (standard)
(e.g. possible Site Status Indication)
SK3 = N° 16 AUXILIARY ON/OFF OUT SIGNALS (optional)
PL4 = N° 16 AUXILIARY ON/OFF IN SIGNALS (optional)
3-8=LINE 2
TEL. LINES
SK6 = N.U.
PL7 = N° 2 Telephon Line
Internal MODEM connected
Figure 1.14. I/O Panel
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-32
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
ON/OFF DATA
(OTHER EQUIPMENT or DEVICE e.g SITE STATUS )
PARALLEL LINE
OTHER EQUIPMENT (I. E.,
VOR, EXTERNAL MODEM, ETC.)
SERIAL LINE ( B) (RS-232)
SERIAL LINE ( A)
RS 232
PL3
SK2
PL1 PL2
Asyncronous
Converter
Interface
PL7
(P C OPTION)
RS 422
RS 232
DME
415 / 435
SERIAL LINE (max. 1km)
(or dedicated line)
STATUS INDICATOR
SI 446 - 2/8
E QUIP ME N T S TA T US
RS 422
SI
ON
AL ARM
AL ARM
W ARN I NG
W ARN I NG
NO RM AL
NO RM AL
LAMP
RS 232
SIL
TEST
OPTION 1
Switched or dedicated teleph. LINE ( C)
PC
CONTROL ROOM
STATUS INDICATOR
SI 446 - 2/8
LINE ( D )
SI
E QU IP ME NT S TA T US
EQUIPMENT ROOM
RS 232
ON
AL ARM
AL ARM
W ARN ING
W ARN I NG
NO RM AL
NO RM AL
LAMP
TEST
RS 232
SIL
OPTION 2
PC
TELEPHONE LINE CONNECTION WITH A
REMOTE CONTROL MONITORING CENTRE
Modem
CONTROL TOWER
NOTE 1: C&D line UNAVAILABLE if A&B line ARE USED and viceversa
NOTE 2: On OPTION 1&2
possible use of
RCSI 446-2/8 Remote Control
Figure 1.15. Local site set up – Typical configuration
1-33
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-33
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
1.6.3.2
LOCAL CONTROL & STATUS UNIT (LCSU)
The LCSU unit is the local main unit connecting the equipment to the remote control system. It also handles
the communication with remote monitoring and control sites, which takes place also through modem and
telephone line(s). It is mounted into the equipment cabinet but it is a functionally separate block. The LCSU
is powered by the service voltages of the DME equipment.
Its main functions:
• sends basic controls to the equipment;
• displays the status of the equipment ;
• interfaces modem(s) connecting the equipment with remote units or PCs;
• interfaces the local PC to control-monitor the equipment and to perform maintenance operations at
the site;
• interfaces the co-located equipment (only on customer request).
•
manages the two modems (optional, placed inside the equipment) that operate with dedicated or
switched lines up to 28.800 bps.
LCSU consists of the following parts (figure 1.16):
•
the Control & Status Board (CSB 186 module) that carries the unit management software.
•
the control panel and the status indicator (INC module) used to forward the basic controls and to display
the equipment operating status.
CSB
CONTROL & STATUS BOARD
CPU & MEMORIES
Port 1
SERIAL LINES COMMUNICATION
Port 2,3
Port 4,5,6
AUX ON/OFF
I/O PARALLEL LINES
AUX ON/OFF
To PC
To I/O PANEL
To Equipment
To I/O PANEL -IN&OUT
n° 12 IN from Equipment
INC
INDICATION & CONTROLS
FRONT PANEL
Figure 1.16. LCSU - Simplified Block Diagram
1-34
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
DRIVER
RECEIVER
RS232C
SERIAL
COMMUNIC.
CONTROLLER
DRIVER
RECEIVER
RS232C
DRIVER
RECEIVER
CPU
RS232C
SERIAL
COMMUNIC.
CONTROLLER
CHANNEL 1
RS232
DCE
To SK1 PC
I/O Panel
CHANNEL 2
RS232
DTE
To PL2 MDM1
I/O Panel
CHANNEL 3
RS232
DTE/DCE
To PL2 MDM2
I/O Panel
M22
DRIVER
RECEIVER
CHANNEL 4
RS232
DCE
RS232C
N.U.
RXD
Indication
DRIVER
RECEIVER
TXD
RS485
CHANNEL 4
RS485/422
M30
DRIVER
RECEIVER
RESET
RS232C
SERIAL
COMMUNIC.
CONTROLLER
RS232C
Reset
Watch-Dog
and Battery
BackUp
Circuit
Watch Dog
Indication
CHANNEL 5
RS232
DTE
To MON 1
module
CHANNEL 6
RS232
DTE
To MON 2
module
M53
DRIVER
RECEIVER
Battery
NI-CD
3,6V
To Transponders (1&2)
(DMD modules)
SOLID
STATE
RELAYS
OUTPUT
REGISTER
16
M32
INPUT
REGISTER
OPTO
COUPLER
RAM - 1Mbit
16
To SK2
and PL3
I/O Panel
and BCPS
PARALLEL
INPUT/OUTPUT
OU 0...4
INPUT
REGISTER
Socket N.U.
INPUT
REGISTER
CONTROLS
from KEYBOARD
To INC
module
M17
OUTPUT
REGISTER
INDICATION to
FRONT PANEL
EPROM
1 Mbit
M21
BUS for
EXPANSION
CSX module (option)
SERIAL
EEPROM
2k x 8
OUTPUT
REGISTER
+5V,+15V
POWER
SUPPLY
M18
Figure 1.17. CSB module – Simplified Block Diagram
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-35
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
1.6.3.2.1
CONTROL AND STATUS BOARD - CSB module – Functional description
The main functions of the CSB module (see figures 1.18 block diagram) are as follows:
− management of interfacing between the equipment and remote system;
− up-dating of the remote site unit;
− communication with the monitors on the RS-232C serial links;
− communication with the transponder equipment on the RS-485 serial link;
− driving of the indications and acquisition of the commands of the INC module
− management of the RS-232C serial communication line with the PC terminal;
− management of the RS-232C serial communication line towards the MODEM and towards an
optional external MODEM for connection to specific remote controls on a telephone line;
− management of the ON/OFF type input and output auxiliary signal using the parallel ports;
− storage of the system configuration in a non-volatile memory (EEPROM);
− management of the calendar for the entire system;
− management of the RS-232C and/or RS-485 serial communication lines that can be used for any
associated equipment connected on a serial link.
− History management
− Management of control function line: Beacon Restart, Automatic Routine check, Warning detection,
Alignment of the Parameter of the intelligent units (Monitors, DMD modules), Searching and Building
of the Data requested by the Remote/Local site through PC
Through the CPU and program memories, the CSB module manages:
− INC Module (Indications and Controls);
− local operator interface through PC;
− interface with remote operator via modem to RCSI/RCSE (Remote Control and Status Unit) or MCS by
means of dedicated or switched telephone line;
− SI 446 (Status Indicator) auxiliary indicator via the parallel ports;
− association between auxiliary ON/OFF input and output lines (parallel ports);
− serial channel operation;
− an RTC (Real Time Clock) calendar with rechargeable buffer battery;
− I/O configuration non-volatile memories.
The composition of the CSB module, shown in figure 1.18, consists in the following function blocks:
− CPU and memories;
− 6-channel serial lines;
− Parallel ports with 16 input and 16 output lines.
1-36
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
MEM
BAUD RATE
GENERATOR
N.U.
PARALLEL
EEPROM
MEM
CPU
SERIAL
EEPROM
uP 80C188
MEM
CONFIGURATION
MEMORY
RTC
REAL TIME
CLOCK
SRAM - EPROM
BACK UP
BATTERY
BUS
CPU & MEMORIES
RS232
DRIVER RECEIVER
SCC
SERIAL COMMUNICATION
CONTROLLER
RS232 DCE
CHANNEL 1
RS232
RS232 DTE
DRIVER RECEIVER
CHANNEL 2
RS232
SCC
LINK
JUMPER
DRIVER RECEIVER
SERIAL COMMUNICATION
CONTROLLER
RS232
CHANNEL 4
RS485
RS485
CHANNEL 4
RS232
DRIVER RECEIVER
SERIAL COMMUNICATION
CONTROLLER
CHANNEL 3
RS232 DCE
DRIVER RECEIVER
DRIVER RECEIVER
SCC
RS232 DTE/DCE
DTE/DCE
RS232 DCE
CHANNEL 5
RS232
RS232 DTE
DRIVER RECEIVER
CHANNEL 6
SERIAL LINES COMMUNICATION
PARALLEL LINE
OPTO
ISOLATOR
INPUT
REGISTERS
N° 8 INPUT GND LEVEL
OPTO
ISOLATOR
PARALLEL LINE
N° 8 INPUT
LINK JUMPER
SELECTOR
LEVEL & POLARITY PRESETTING
OUTPUT
REGISTERS
OPTO SOLID
STATE RELAYS
PARALLEL
N° 16 OUTPUTS
N° 5 OUTPUTS TTL
I/O PARALLEL LINES
INPUT/OUTPUT
REGISTERS
CSB
INC
INDICATION &
CONTROLS PANEL
PC
RS232
CONTROL & STATUS BOARD
Figure 1.18. CSB module – General Block Diagram
1.6.3.2.1.1 CPU and Memories
The 80C188 type microprocessor works internally with a frequency of 7.3728 MHz by means of a double
frequency quartz (it is divided internally by the CPU) and it uses integrated circuits UL6,7,8 to manage the
data bus and address buses (see figure 1.19 ). The 14.7456 MHz quartz frequency is used by the baud rate
generator of the SCC (Serial Communication Controller) and passes without alteration from FW2 (in cases
of quartz frequency change, the clock can be divided) to provide the BRGSCC signal.
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-37
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
The multiplexed portion of the address bus is stored in two latches (UL6 and UL7) in order to have stable
signals during the various CPU cycles.
The data bus is connected to the peripherals and the memories by a bi-directional buffer (UL8). This
solution has been used, to overcome not bus electric drive problems, but peripheral problems (such as the
RTC that does not release the bus before the CPU starts the next cycle).
A perpetual real time calendar (RTC - Real Time Clock) useful to date the events stored in the “history” is
installed to ensure the data concerning events that have taken place in the history of the TACAN equipment
is picked up. The manual updating of the date is managed by the “Supervisor” program.
The function is provided by the low consumption integrated circuit (4 μA at 2.2 V) UL5 (RTC) that operates
with a 38.768 kHz ceramic quartz.
This updates and supplies the complete actual date to the μP. The RTC memory is not lost when there is no
direct voltage since the BT1 buffer battery is switched onto UL5 from IC UL4 that constantly compares the
+5 Vdc. If this is missing, a switching electronic device enables the BT1 battery.
Under these conditions, the typical life of the rechargeable NiCd battery (3.6 V and 60 mA/h) is approx. six
months.
Through the FW1 circuit (Firmware EPLD - Electrical Programmable Logic Device), the IC UL4
(Supervisory) indicates that the program running will retrigger the timer correctly and consequently LED
“WD” (Watch Dog) RD4 will remain alight, indicating that the program running is correctly active.
In the case of a hardware fault or software failure, LEDs RD4 and OPERATION (of the INC) will not light up,
indicating that the CSB module is not operating correctly.
Integrated circuit IC UL4, besides monitoring the CPU activity, also checks the level of the +5 Vdc; if this
degrades to values below ≤ 4.65 V a “Warning” signal is generated. Integrated circuit IC UL4 also checks
the state of the buffer battery, and through the BATF signal indicates the Warning State.
IC UL16 (serial EEPROM) stores the I/O system configuration data, that does not usually vary a lot; it can
hold data for about 100 years, and this is the reason why another type of less secure memory (RAM) is not
used with a buffer battery.
RESET push-button I1 is used to restore and reinitialize the CPU program.
Integrated circuits FW1 and FW2 are specifically programmed to decode the selection of memories and I/O
peripherals, and to generate a clock for the serial port controllers.
The EPROM memories for the program (M7) and SRAM (UL9) have memories a capacity of 1 Mbit (128k x
8), but other sizes can be installed, up to the maximum μP addressing capacity (8 Mbit).
There is another socket on the printed circuit (not usually used) where an SRAM/EEPROM with capacity up
to 8 Mbit can be installed.
The UL9 SRAM memory where the events (history) data are loaded is always powered. When there is no +5
Vdc supply, this is substituted by the rechargeable buffer battery. By correctly setting the jumpers on the
CSB board, the other optional memories can also be supplied by the buffer battery. In this case, the battery
life will be reduced to 2 months.
For the memory rate, with a 10 MHz clock and a 16 MHz CPU, memories with an access time of 100 ns are
sufficient.
UL2 is an analog switch that electrically isolates the SRAM when operating by battery.
When the LOW LINE signal is present, activated each time the VDC drops below 4.65 V, the RTC circuit is
electrically isolated from UL2 to prevent undesired access and reduce consumption to a minimum in standby conditions (battery powering).
1-38
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
CSB
CPU & MEMORIES
AN5
CK
RES
14.7456
MHz
A BUS
Q1
A BUS
CPU
AN3
LATCH
AS BUS
µP 80C188
UL6
INTSCC
AN1
AD BUS
INSCC0
LATCH
UL7
PCS
UL3
TRANSCEIVER
AN7
AN6
RD
WR
D BUS
UL8
EPROM
A BUS
128K x 8
D BUS
M7
SRAM
Power
Down
128K x 8
D BUS
UL9
PARALLEL
EEPROM
32K x 8
M8
BRG
Q2
32,768 KHz
CLOCK
BAUD RATE
GENERATOR
& DELAYER
PCS
RTC
WR
A BUS
REAL TIME
CLOCK
BRGSCC
DEL_WR
D BUS
MEM DECODER
UL5
MCS
WRCS
VBAC
I/O DECODER
MCS3
ANALOG
SWITCH
RDCS
PROGRAM. FIRMWARE
FW1- FW2
LOWLINE
UL2
WR
CS9
I1
AN4
VBAC
AN2
Vcc
VBATT
CPU
RESET
+ -
UL1c
mP SUPERVISORY
BATT & 5VCC
CONTROL
WD
BT1
GREEN
AUTORESET
ENABLE
WDI
UL4
RD4
UL1d
AN8
BATF
Figure 1.19. CSB module – CPU and Memories: Block Diagram
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-39
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
1.6.3.2.1.2 Serial Lines
There are six serial communication channels in the RS-232C configuration (figure 1.20 block diagram), or
five in the RS-232C configuration and 1 in the RS-485 configuration which can be selected by suitable
jumpers.
The transmission rate is selected during the configuration stage.
Channel 1, 2, 3 and 4 outputs transit on the 64-pin M22 speedy connector that can be used on the I/O panel
connectors SK1, PL1, SK2 for channels 1, 2 and 4 respectively whereas channel 3 is used for
communication with the equipment (of SK2-IRS module). Channel 4 on SK2 is preset in RS-232C
configuration, whereas selecting the M24 connector jumpers it transits on connector M30 (10-pin speedy)
that can be preset in RS-485 configuration. Channel 5 and 6 outputs through connector M53 (34-pin
speedy) are brought onto PL4 and PL2 of the I/O panel.
Serial channel 1
Channel 1, managed by UL21 SCC (Serial Communication Control) and driven by IC “UL22” (RS-232 Driver
Receiver) is in the DCE standard (Data Communication Equipment) RS-232C configuration and is
connected to the PC through connector SK1 on the I/O panel. The PC can be connected to the INC module
SK6 (PC RS232) connector as this is in parallel directly to the I/O panel connector SK1.
Serial channel 2
Channel 2, managed by UL 21 SCC (Serial Communication Control) and driven by IC “UL23” (RS-232
Driver Receiver) is in the DTE standard (Data Terminal Equipment) RS-232C configuration and can be
connected to the possible external modem via PL1 on the I/O panel. Signals synchronizing the receiving
and transmission clocks (RXCK and TXCK) are to be used for modem.
Serial channel 3
Channel 3, managed by UL26 SCC (Serial Communication Control) and driven by IC “UL30” (RS-232 Driver
Receiver) can be either RS-232C DCE or DTE configuration according to the arrangement of the M31
connector jumpers.
It communicates with the beacon through the IRS interface in DCE configuration.
Serial Channel 4
Channel 4, managed by UL26 SCC (Serial Communication Control) and driven by IC “UL29” (RS 232 Driver
Receiver) is in the DCE standard RS-232C configuration, when connected to M22; it is in the RS-422/485
configuration driven by Drivers/Receivers UL24, UL28, UL25, UL31 if connected to M30.
The transformation from the RS-232C configuration to RS-422/485 configuration is preset through the
jumpers of connector M24 that switch the RXD signals either on IC UL29 (RS-232C) or on UL24 (RS422/485).
RS-422/485 can be used with 4 or 2 wires by suitably setting the jumpers of connector M25.
RD8 and RD9 LEDs driven by UL1f and UL27b, when flashing, indicate respectively the RXD and TXD data
transit and indicate that channel 4 is working efficiently.
Serial channels 5 and 6
Channels 5 and 6, managed by UL32 SCC (Serial Communication Control) and driven by IC “UL33 and
UL34” (RS-232 Driver Receiver) are in the RS-232C DTE configuration, the use of which is conventionally
defined as connection on PL4 and PL2 of the I/O panel for modem.
NOTE
Generally, the DTE configuration can be directly connected to the
modem and the DCE to the PC. To connect a DCE channel to
another DCE channel or another DTE, a “null modem” adapter is
necessary.
1-40
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
RS232
SCC
A BUS
UL23
SERIAL
COMMUNICATION
CONTROL
D BUS
TXD - RTS - DTR
DRIVER/RECEIVER
CH1
To SK1
PC
DCE
RXD - CTS - DCD
RXCK
CH2
RS232
DEL_WR
DRIVER/RECEIVER
BRGSCC
UL22
PCS
DTE
RXD - CTS - DCD - TXCK
MODEM
TXD - RTS - DTR
UL21
INT
SCC
UL1a
1EI
M22
UL27a
INT
SCC
CH3
N. 6 SWITCH
RS232
SCC
DRIVER/RECEIVER
DTE/DCE
SELECTOR
DTE/DCE
M31
PCS
UL30
SERIAL
COMMUNICATION
CONTROL
RXCK-TXCK
RS232
DRIVER/RECEIVER
UL29
UL26
TXD - RTS - DTR
CH4
RS232
DCE
RXD - CTS - DCD
M24
RD8
UL1f
RXD
GREEN
RECEIVER
RS485 RX
UL24
TXD
GREEN
RD9
DRIVER
RS485 TX
UL28
UL27b
CH4
RXCK
RS485
RECEIVER
UL25
RS485 CK
TXCK
DRIVER
M30
UL31
RS232
SCC
TXD - RTS - DTR
CH5
DRIVER/RECEIVER
DTE
RXD - CTS - DCD
UL33
SERIAL
COMMUNICATION
CONTROL
D BUS
A BUS
RXCK
RS232
RXD - CTS - DCD - TXCK
CH6
DRIVER/RECEIVER
DTE
PCS
UL32
UL34
TXD - RTS - DTR
M53
INT
SCC
UL27d
Figure 1.20. CSB module – Serial lines: Block Diagram
1.6.3.2.1.3
Parallel ports
The parallel ports are divided into (see figure 1.21):
− Input ports:
8+8 optoisolated lines (galvanic isolation) for the user’s specific applications such as: maximum or
minimum temperature level alarms, presence of smoke, anti-vandal alarms, obstacle lights operation
check etc.;
4 TTL level lines used by the beacon;
6 bits to interface INC panel commands;
16 optional lines on CSX expansion board upon specific request from the user.
− Output ports:
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-41
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
16 optoisolated solid state relay lines, that can be used (by the user) as indication signals
5 TTL level lines;
16 bits to interface the INC Module indications;
16 optional lines on the CSX expansion board upon user’s request.
− Input lines. The lines transit from connector M32 to connector PL3 on the I/O panel and are divided as
follows:
8 lines (IAUX 0...7) in two groups of four lines, which have one common for each group.
Each line, by means of its optoisolator, drives two 4-bit input registers (UL19a and UL19b), one for each
group.
The electrical characteristics of the control levels must include a contact to ground, and a typical current
value of 3mA, maximum 30 mA (max. 500 mAp @ 100 μs).
8 lines (IAUX 8...15) made up of two groups of four lines, with one common for each group.
Each line, through its optoisolator, drives two 4-bit input registers (UL20a and UL20b), one for each
group.
The electrical characteristics of the control levels may include a contact to ground or a positive level,
according to the arrangement of the line through the jumpers of connectors M49, M50, M51 and M52
(two lines each) and a typical current of 3 mA, maximum 30 mAp (max. 500 mAp @ 100 μs).
NOTE
Lines IAUX10 to IAUX15 are used internally by the
equipment and therefore are not available for the user.
4 lines (IN 0...3), TTL level, to determine the primary power supply functioning of the BCPS unit.
Each line drives an 8-bit input register (UL14 e).
On I/O panel connector SK4, lines IN0 and IN1, parallel to those on I/O panel connector PL3, are
available through connector M30.
The six bits (CPI1, 2,3) coming from the encoder of the INC module controls, drive the 4-bit input
registers UL13a and UL13b.
− Output lines. The lines transit from connector M32 to I/O panel connector SK4. They are divided as
follows:
16 lines (OAUX 0...15) in four groups of four lines, with one common for each group.
The lines are driven by two output registers (UL17 and UL18) where each register controls 8 outputs.
Each line controls an electronic optorelay that has the following output features:
− Max. applied voltage: 350 Vp;
− Max. current: 100 mAp (100 mA @ ± 7 V load);
− Closing resistance: 50 Ω
− Leakage current at 300 V: 40 μA;
5 TTL lines are also available, three on connector SK4 and two on I/O panel connector PL3.
They are driven by the 8-bit output register UL12 that exchanges the data of the EEPROM serial memory
UL16 via UL15a and the “Serial Clock” and “Serial Data” signals.
Through the 8-bit output registers UL10 and UL11, the 16 bits of the CPD and CPA buses drive the
sequence of indications on the INC Module.
1-42
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
OPTO
INSULATORS
4BIT INPUT
REGISTER
D BUS
UL19a
IAUX 0..3
OP9b-OP10a,b-OP11a
N° 8 INPUT
OPTO
INSULATORS
4BIT INPUT
REGISTER
UL19b
IAUX 4..7
OP11b-OP12a,b-OP9a
OPTO
INSULATORS
4BIT INPUT
REGISTER
JUMPERS
SWITCH
OP21a,b
OPTO
INSULATORS
UL20a
JUMPERS
SWITCH
OPTO
INSULATORS
4BIT INPUT
REGISTER
IAUX 10.11
N° 8 INPUT
POLARITY & LEVEL
PRESETTING
M50
OP22a,b
RDCS
IAUX 8.9
M49
JUMPERS
SWITCH
IAUX 12,13
M51
OP23a,b
OPTO
INSULATORS
JUMPERS
SWITCH
UL20b
IAUX 14.15
M52
OP24a,b
M32
8BIT OUTPUT
REGISTER
OPTO RELAIS
UL17
OP1-OP2-OP3-OP4
A BUS
OAUX 0..3
OPTO RELAIS
OAUX 4..7
WRCS
OP5-OP6-OP7-OP8
N° 16 OUTPUTS
8BIT OUTPUT
REGISTER
To
CSX
OPTO RELAIS
OP13-OP14-OP15-OP16
UL18
M21
OAUX 8..11
D BUS
OPTO RELAIS
WRCS
OAUX 12..15
OP17-OP18-OP19-OP20
SCL
SERIAL
EEPROM
+5VCC
±15V
8 BIT OUTPUT
REGISTERS
OUT 0..4
N°5 TTL OUTPUT
2kx8
UL12
UL16
WRCS
SDA
D BUS
8 BIT INPUT
REGISTER
IN 0..3
N° 4 TTL INPUT
BCPS 1,2,3,4
UL14
IN 0..3
CPD;CPD Bus
WRCS
M30
RDCS
UL10-UL11
To
INC
8 BIT OUTPUT
REGISTERS
SDA
M17
PF 1/2
4 BIT INPUT
REGISTER
CPI 1,2,3
UL13a,b
M18
RDCS
RDCS
WRCS
+5VCC
±15V
BATF
Figure 1.21. CSB module – I/O Parallel Ports: Block Diagram
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-43
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
1.6.3.2.2
LOCAL FRONT CONTROL PANEL
The front panel of LCSU (part of the INC module) is shown in figure 1.22.
It is divided in the following parts:
one dedicated to the unit itself, and one dedicated to the equipment.
1)
The part dedicated to the LCSU status contains:
−
OPERATION connected directly to the "watch dog signal" of the CPU 186,
−
WARNING not used and always off,
−
DATA COM not used and always off,
−
buzzer (S1),
−
button SIL to silence the buzzer and the
−
LAMP TEST button;
2)
The part dedicated to the equipment comprises the following sections:
beacon MAIN STATUS indications: this section includes the four alphanumerical devices for beacon
site code, the ALARM, WARNING, NORMAL and DATA COM general status indications.
3)
DETAILED STATUS indications; these indications are requested by the operator by pressing the
SELECT button, the triangular sign indicates enabling of the following detailed indications:
ALARM, STBYALRM, FAULTY and BYPASSED are monitor indications:
MON 1/2 alarm, MON 1/2 stand by alarm, MON 1/2 faulty, MON 1/2 bypass
ON, WARNING, FAULTY and ON ANT are transponder indications:
TX 1/2 on, TX 1/2 warning, TX 1/2 faulty, TX 1/2 on ant.
a) For each MONITOR indication(Mon1 & Mon2):
− ALARM - Means the monitor see an alarm on the transponder on antenna
− STBYALRM - Means the monitor see an alarm on the transponder on dummy load
− FAULTY - Means the monitor found itself wrong
− BYPASSED - Means the monitor is bypassed because the beacon is in Maintenance Mode
b) For each TRANSPONDER indication (TRX1 & TRX2):
− ON - Means the transponder is ON (radiating if it is on antenna)
− WARNING - Means the transponder found a warning condition (e.g. different command by
monitors)
− FAULTY - Means the transponder is faulty
− ON ANT - Means the transponder is on antenna
4. Station control (CONTROL STATION):
−
Indication of control enabled by a remote control (ENGAGED),
−
Indication of local control enabled (ENABLED).
−
Priority activation/de-activation button in local control (REQUEST RELEASE).
−
Indication of mains failure (MAINS OFF).
−
Indication of optional site alarms (ENV ALARM).
−
Indication of optional antenna alarm (ANT FTY) – Not used on the DME
1-44
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
−
955 900 031C
General indication of the faults that may occur in the equipment (OTHER WARN).
5. Beacon commands (COMMAND):
− ON/OFF button (EQUIP ON/OFF) and
− transponder on antenna change over (CHANGE OVER).
MAIN
STATUS
LCSU
DETAILED STATUS
MON 1
PC
RS232
RD1
ALARM
RD31
WARNING
RD30
MON 2
RD26
ALARM
RD27
OPERATION
RD25
RD17
WARNING
FAULTY
FAULTY
FAULTY
FAULTY
BYPASSED
BYPASSED
ON ANT
ON ANT
RD28
RD21
RD12
RD22
RD23
RD13
DATA COM
COMMAND
RD24
EQUIP
CHANGE
OVER
I2
I3
RD7
RD14
RD18
DATA COM
RD4
RD19
RD33
STATION
ENGAGED
MAINS OFF
ENABLED
ENV ALRM
RD5
I4
SIL
I6
RD20
ANT FTY
REQUEST
RELEASE
S1
RD9
CONTROL
RD10
ON/OFF
WARNING
WARNING
RD15
RD32
I1
ON
STBYALRM
RD29
SELECT
TX 2
ON
STBYALRM
NORMAL
RD11
TX 1
RD16
ALARM
RD8
OTHER WARN
RD6
LAMP
TEST
I5
LOCAL CONTROL & STATUS UNIT
Figure 1.22. Local Front Panel
1.6.3.2.2.1 INDICATION AND CONTROLS - INC Module - functional description
The INC Module block diagrams are shown in figures 1.23, 1.24, 1.25.
All the electrical components are mounted on the INC module board. A transparent waterproof membrane
protects the luminous components.
The commands from I1 to I16 have a common ground and communicate with the CSB module register
through the encoder consisting in UL14a,b,c - UL15a - UL11e,f - UL8b. The program reads the coded data
by “polling” and the “debounce” is foreseen by software. The three six-bit signals (CPI 1, 2, 3) pass from
module INC connector M1 to connector M17 when module CSB is inserted.
The communication for program data exchange is through the CPA and CPD buses controlled by CSB
module registers UL10 and UL 11.
The circuits are divided into the following blocks:
Address Decoders
Circuits UL3 and UL4 generate the flip-flop chip selects and the alphanumeric display.
Brightness Control
currents are at the set value.
The brightness of the OPERATION LED-bar is controlled separately by circuits UL11a, UL12a, UL11d and
UL11a,b.
A single current peak limiter circuit (TR1 and UL3) for all the LED-bars, reduces the transient currents to
values that do not jeopardize the components.
LED-bar and driver
Flip-flops UL6, 10,13,16 each control groups of 8 LED-bars. Each LED-bar has four separate LEDs in order
to have a wide lighted surface.
The four-digit device on the alphanumeric display (RD1) is an integrated component, with its functions,
including the luminous elements, built in the chips.
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-45
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
display
driver
Indication panel
Audible
device
driver
Alarm device
CSB
PC connector
local
Key panel
driver
key panel
Figure 1.23. INC module - simplified block diagram
Siren (Buzzer)
A siren with a fixed frequency is controlled by flip-flop UL1 and it can be silenced manually through
command 16.
INC
I1
I2
CPI1
CPI2
I3
COMMAND
ENCODER
N° 1 LED BAR
N° 8 LED BAR
N° 8 LED BAR
N° 8 LED BAR
CPI3
INRUSH
CURRENT
CIRCUIT
N° 5 LED BAR
VLED
I4
CLOCK
GENERATOR
I5
I6
M1
VCC
"LCSU OPERATION"
BRIGHTNESS
CONTROL
BUZZER
OPERATION
WDO_LED
BR1
4 ALPHANUMER. DISPLAY
To
CSB
WR D0-D6
AOA1 CU.SE
FLIP FLOP
OC
EN
CPD7
D1-D8 CLK
LEN1
FLIP FLOP
OC
LEN2
D1-D8 CLK
FLIP FLOP
OC
D1-D8 CLK
LEN3
FLIP FLOP
FLIP FLOP
OC D1-D8 CLK
OC
D1-D8 CLK
GND
LEN4
CPD BUS
LEN2
BR1
CPWR
CPA BUS
CLK_0
LEN1
CLK_2
CLK_3
BRIGHTNESS
CONTROL
CLK_4
CLK
DECODER
DECODER
LEN4
LEN3
CLK_1
EN
ENDIS1
CLK_5
WDO
Figure 1.24. INC Module - Indication and Control: General Block Diagram
1-46
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
CPA0,1
ENDIS
DPY LED
ALPHANUMERIC DISPLAY
CPD0...6
M1
RD1
CPWR
CPA BUS
WD0
CLK 4
DECODER
CLK
Flip-Flop
LATCH
CPD BUS
UL3
S1
UL1
CPA0,1,6
+5
VCC
VCC
CPA2..5
DECODER
BRIGHTNESS CONTROL
UL4
MUX
CLK 5
UL5
CLOCK GENERAT.
SQUARE OSCILLATOR
UL8a
UL2
CPD0...7
REGISTER
SERIAL INPARALL.OUT
UL7
3 STATE BUFFERS
UL9a,b,c,d
INRUSH CURR.CIRCUIT
CPD BUS
TR1
VCC
LEN
Flip-Flop
LATCH
BUFFER
LEN 1
UL6
CLK 0
Flip-Flop
LATCH
BUFFER
UL10
LEN 2
N° 8 LED BAR
CLK 1
RD 12,13,14,15,17,18,19,20
Flip-Flop
LATCH
BUFFER
UL13
LEN 3
VLED
N° 8 LED BAR
RD 4,5,6,7,8,9,10,11
N° 8 LED BAR
CLK 2
RD 21,22,23,24,25,26,27,28
LEN 4
Flip-Flop
LATCH
BUFFER
UL16
N° 5 LED BAR
CLK 3
RD 29,30,31,32,33
BRIGHTNESS CONTROL
BR1
N° 1 LED BAR "OPERATION"
UL11b
WDO_LED
UL11a UL12a UL11d
UL11c
M1
EQUIP
ON/OFF
SELECT
I1
CP1
I2
RD16
CHANGE
OVER
REQUEST
RELEASE
I3
I4
LAMP
TEST
SIL
I5
I6
COMMAND
ENCODER
CP2
CP3
UL14 a,b - UL15a
UL11 e,f - UL8b
Figure 1.25. INC Module - Indication and Control: Block Diagram
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-47
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
1.6.3.3
REMOTE CONTROL SYSTEM
RCSI 446 or RCSE 443 – Remote Control & Status Indicator - is a unit for remote control and maintenance
operations (for detailed information to see RCSI 446 or RCSE 443 Technical manual).
An updated remote control, MCS (Monitoring and Control System), with resident software on PC, work with
modern programs that only run on hardware of a typical PC (for detailed information to make reference to the
MCS Technical manual)
The possible remote site connections with the local station are shown in figure 1.26.
The examples of remote site connections with the local station are shown in figures 1.27 and 1.28.
optional
ON/OFF
DATA
modem
RCSI/RCSE
SWITCHED
NETWORK
(PSTN-Public Switching
Telephon Net.)
optional
ON/OFF
DATA
modem1
ON/OFF
DATA
modem
RS232 B
RCSI/RCSE
PL3
SK2
modem 2
PL1 SK1
PL2
DEDICATED
LINE
RS232 A
DME
modem
RCSI/SI
446 2/8
NOTE
1) RS232 line (A) UNAVAILABLE if
RS232 line ( B) is used or viceversa
2) "External" MODEM 1&2 Unavailable
if "Internal" MODEM are used and viceversa
Figure 1.26. Possible connection between Remote RCSI/RCSE and Local site
1-48
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
REMOTE CONTROL STATUS INDICATOR
RCSI 446-2
E QUI P ME N T
D ETAI LED STA TUS
MA IN STATUS
STATUS INDICATOR
SI 446 - 2
RC S I
R C SI 446
RS 422 (<1km)
SI
EQ UIPM E N T ST AT US
RS 422/485
RS 232
ON
ALARM
ALARM
WARNING
WARNING
NORMAL
NORMAL
L AMP
CO MM AN D
SI L
TEST
PC
Switched or dedicated teleph. LINE
CONTROL TOWER
O ptio n al E N V IR O N M E N T A LA R M S
(S M O K E , T E M P ., IN T R U S IO N , ...)
CENTER CONTROL ROOM
DEDICATED LINE
STATUS INDICATOR
SI 446 - 2
SI
EQ UIPM EN T ST AT US
RS 232
DEDICATED
or SWITCHED LINE
RS 232
ON
ALARM
ALARM
WARNING
WARNING
NORMAL
NORMAL
LAMP
TEST
SIL
PC
RS 232
Modem
DME
(D)VOR
EQUIPMENTS LOCAL SITE
Figure 1.27. Example of single site connection with RCSI
REMOTE SERVICE MAINTENANCE
CONTROL CENTER
REMOTE CONTROL
& STATUS INDICATOR
RCSI 446-8
EQUIPMENT
RS 232
M AIN STATU S
CONTROL TOWER
DE TAI LE D STATU S
MON 2
TX1
MON 1
RS 422 (< 1 Km.)
O PE RA TI ON
TX2
WA RN IN G
ST AN D BY
ALARM
ALARM
ALARM
WARNING
WARNING
WARNI NG
ALARM
ALARM
ALARM
WARNING
WARNI NG
WARNING
ALARM
ALARM
ST AN D BY
FA UL TY
FA UL TY
BY PA SS ED
WARNI NG
BY PA SS ED
WA RN IN G
FA UL TY
O N AN T
WA RN IN G
D ATA CO M
FA UL TY
SI
EQUIPMENT STATUS
RCSI
O N AN T
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
RS 232
ON
AL AR M
WA RN IN G
AL AR M
AL AR M
WA RN IN G
WA RN IN G
N OR MAL
N OR M AL
AL AR M
AL AR M
AL AR M
AL AR M
WA RN IN G
WA RN IN G
WA RN IN G
WA RN IN G
WA RN IN G
N OR M AL
AL AR M
N OR M AL
N OR M AL
N OR M AL
WARNING
LA MP
NORMAL
NORMAL
D ATA CO M
D ATA CO M
D ATA CO M
D ATA CO M
D ATA CO M
D ATA CO M
D ATA CO M
D ATA CO M
SE LE CT
SE LE CT
SE LE CT
SE LE CT
SE LE CT
SE LE CT
SE LE CT
SE LE CT
CONTROL
STATION
EN G AG ED
M AI N S OF F
EN A BLE D
EN V A LRM
N OR M AL
N OR MAL
TE ST
SI L
SI L
COMMAND
EQ U P
O N/ O FF
C HA NG E
R EQ UE ST
O VE R
R ELE AS E
AN T FT Y
O TH ER WA R N
RCSI 446
STATUS INDICATOR
SI 446-8
L1 - DEDICATED LINE
DEDICATED LINE - L3
L2 - DEDICATED
or SWITCHED LINE
RS 232
RS 232
RS 232
MARKER
ILS
LOC
ILS
NDB 436
DME
DME
(D)VOR
GP
EQUIPMENTS LOCAL SITES
Telephon line 1 = dedicated line connetting with Modem party-line
Telephon line 2 = dedicated or switched line used for: measurement, preset and indication, (no commands) ,
connetting with Modem. Indication are displayed on PC connecting at RCSI
Telephon line 3 = dedicated line connetting with Modem
Figure 1.28. Example of multi site connection with RCSI
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-49
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
RMC 443
INC
REU
SIB
DIAL MODEM LGM
MAINTENANCE CENTER
PTT LINES
JBUS
AIRPORT
TOWER
RCSE 443
RSU
RS422*)
REU
INC
DIAL MODEM LGM
CTU
RS422*)
RWY
SELECT
SIB
Ligne
OIO
MODEMS LGM**)
Panel
Control ON/FF
(Client)
STATIONS
(AN 400)
MODEM
LOC
MODEM
FFM
*) RS422 interface to equipment situated
in a different building than RCSE LGM Extender 2 Unit has to be used!
MODEM
MODEM
MODEM
M 4000
Marker
GS
MODEM
DME
**) alternatively the ILS stations can be connected
via RS232 or RS422 dedicated lines to the RCSE
(Multiplexer RS232 board is used in RCSE,
RS232 interfaces instead of ZUA modem withinILS stations)
Figure 1.29. Example of multi site connection with RCSE
1.6.3.3.1
Remote Control & Status Indicator (RCSI 446)
The RCSI 446 is used by a remote site to control both the beacon and other equipment or devices of the
local site.
Two versions are available: RCSI 446-2 to handle up to two equipment and RCSI 446-8 to handle up to eight
equipment. Both units might be connected through dedicated lines, switched lines, radio link, etc.
Main functions of the RCSI:
- sends basic controls to the equipment (one equipment at a time; equipment(s) may also be of different
types);
- displays the status of the equipment;
- drives supplementary Status Indicators (SI 446);
- interfaces the PC to control-monitor the equipment and to perform maintenance operations like the
LCSU at the local site.
The RCSI 446-2/8 is housed in a standard 19" rack container. It comprises:
1-50
the Control & Status Board (CSB386 module)
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
the front panel (made with water – proof elastic membrane) for commands and indications. The
LEDs and pushbuttons are mounted on the INC-2 or INC-8 board module. The front panel replicates
the INC module of the LCSU, plus eight status indication sections for any related equipment
the modem(s) (optional) capable to operate with dedicated/switched lines up to 28.800 bps; up to
three modems can be housed inside the unit rack.
the power supply (ac/dc or dc/dc alternatively).
The rack RCSI 446 - 8 is shown in Figure 1.30.
For further information, refer to the specific manual of the RCSI.
MODEM 1
INTERFACE (OPTION)
UPS (OPTION)
POWER SUPPLY
AC/DC or DC/DC POWER SUPPLY
MODEM (OPTION)
EQUIPMENT
RCSI
MAIN STATUS
DETAILED STATUS
MON 1
MON 2
TX 1
AERIAL
AERIAL
ON
ON
STANDBY
WARNING
WARNING
FAULTY
FAULTY
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
FAULTY
FAULTY
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
BYPASSED
BYPASSED
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
DATA COM
DATA COM
DATA COM
DATA COM
DATA COM
DATA COM
DATA COM
DATA COM
SELECT
SELECT
SELECT
SELECT
SELECT
WARNING
DATA COM
ON ANT
ON ANT
CONTROL
STATION
ENGAGED
MAINS OFF
ENABLED
ENV ALRM
SIL
COMMAND
SELECT
OPERATION
STANDBY
ALARM
SELECT
TX 2
EQUIP
ON/OFF
SELECT
ANT FTY
REQUEST
CHANGE
OVER
RELEASE
OTHER WARN
LAMP
TEST
RCSI 446
Figure 1.30. RCSI-8 – Remote control
1.6.3.3.2
Remote Control and Status Equipment (RCSE)
The RCSE is intended to be installed in the maintenance equipment room. It provides separate status
display and on/off-control functions for all Navaids equipment, and mechanisms to change and display
auxiliary data words for MLS. The RCSE consists of the Remote control Electronic Unit (REU) with an
Indication and Control (INC) panel. The RCSE is interfacing with one or two Control Tower Units (CTU), with
a maintenance data terminal (PC) and optionally with a slave RCSE panel unit defined as Remote Status
Unit (RSU). The CTU is intended for installation in the ATC control tower. It provides system ’main status’
indications and may provide a separate status display for each Navaids subsystem as well as switching the
ILS or MLS to the active runway (RWY-select, optional).
EQUIPMENT
ALARM
MAIN
STATUS
RC
DETAILED STATUS
MON 1
ALA RM
ALA RM
ALA RM
ALARM
ALARM
ALA RM
MON 2
TX 1
AERIAL
AERIAL
STAND BY
STAND BY
WA RNING
WARNING
FAU LTY
FAULTY
FAULTY
FAULTY
BYPASSED
BYPASSED
ON AN T
ON ANT
ON
WA RNING
WA RNING
WA RNING
WA RNING
WARNING
WA RNING
WA RNING
NOR MAL
NOR MAL
NOR MAL
NOR MAL
NOR MAL
NORMAL
NOR MAL
NOR MAL
DA TA COM
DA TA COM
DATA COM
DA TA COM
DA TA COM
DA TA COM
DA TA COM
CONTROL
MAINTEN
MAINTEN
MAINTEN
MAINTEN
MAINTEN
MAINTEN
MAINTEN
ON
ALA RM
WA RNING
DATA COM
TX 2
OPER ATION
WA RNING
DATA COM
STATION
ENGAG ED
MAINS O FF
ENAB LED
ENV A LRM
SIL
MAINTEN
COMMAND
AN T FTY
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
SELECT
EQUIP
ON/OFF
CHANGE
OVER
REQUEST
RELEASE
OT HER W A RN
LAMP
TEST
Figure 1.31. RCSE 443 – Remote control
The front RCSE 443 is shown in Figure 1.31 and CTU & Runway select , optional in figure1.32.
For further information, refer to the specific technical manual of the RCSE.
Vers. D, September 2005
THALES Italia S.p.A.- A. S. D.
1-51
DME 415/435 -Technical Manual
Vol. 1-Section 1-General Information
955 900 031C
Control Tower Unit (CTU)
AIR NAV SUBSYSTEM
RunWaY Select
RWY-SELECT
Figure 1.32. RCSE 443 – Remote control CTU & RunWay select
1.6.3.3.3
MCS
The RMMC network has a radially configured architecture based on communication between Monitoring and
Control Systems (MCS) on different levels, local (airport) and remote (regional, national, international). The
MCS systems are connected via WAN/LAN Internet or via switched/private lines in the public network (PTT)
and dedicated lines in private networks. A direct Navaids shelter access is possible via a serial or
(optionally) via an Ethernet connection.
With the use of the MCS for control and monitoring via personal computer (PC) a user-friendly interface for
the supervision adjustment and modification of relevant operating data according to the respective
operational application is made available for first set up and ongoing operation of the terrestrial and satellite
navigation equipment (e g. VOR, DME, ILS, MLS, ADS-B). The use of common PC standards and operating
systems ensures a familiar operating environment for the user (see figure 1.33).
For detailed further information, refer to the specific technical manual of the MCS.
Figure 1.33. MCS – Remote control
1-52
THALES Italia S.p.A.- A. S. D.
Vers. D, September 2005

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 60
Page Layout                     : OneColumn
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:eaef6773-877a-443b-917d-78589731425c
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2006:03:17 15:13:33+01:00
Creator Tool                    : Acrobat PDFMaker 7.0.5 for Word
Modify Date                     : 2007:09:05 14:16:11-05:00
Metadata Date                   : 2007:09:05 14:16:11-05:00
Document ID                     : uuid:d2299722-15c4-4dae-bb29-b433cf97f905
Instance ID                     : uuid:f7a3f68c-d070-4935-bfc8-f9b4c8e9dd43
Format                          : application/pdf
Title                           : Microsoft Word - DME 400 STD eng vol 1 sect01  Gen Inform sept05 _jan06ok_.doc
Creator                         : 
Author                          : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BOJ435

Navigation menu