Third Millennium Systems AV90 Access Control Reader, Model AV90 User Manual USERS MANUAL
Third Millennium Systems Ltd. Access Control Reader, Model AV90 USERS MANUAL
Contents
- 1. User Manual
- 2. User manual
- 3. Users Manual
- 4. USERS MANUAL
USERS MANUAL
3M S-Gang Keypad style or technology - now you can have both MANUAL Product Features Designed to embrace cutting-edge RFID technologies in a stylish and innovative package, this advanced access control reader offers a refreshing breakthrough in the access security marketplace. Shaped in a sleek singlegang style design, with an RGB LED illuminated keypad, offering ‘prox-and-pin’ security, the reader may be fixed directly onto a US electrical backbox. This powerfully secure and innovative reader has a beautifully clean aesthetic, and a bright RGB LED that can be applied to many applications such as colour coded access levels, migration status or mood lighting. The reader housing is moulded using tough polycarbonate plastic, and includes a shadow-line backplate, a subtle and simple mechanical design feature that makes the reader, when fixed, appear to float against the wall. • • 125KHz 13.56MHz • Bluetooth LE • • • • • • • • Black textured moulding Slim profile RGB LED Fully encapsulated electronics RGB illuminated keypad Wide range of output formats 5 year limited warranty Read range up to 10cm (4 inches) Proximity Smart Contactless Images shown in this document are for illustrative purposes only. The features, colours, style and appearance may change without notice. © 3millID 100-02640-A 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com 3M S-Gang Keypad style or technology - now you can have both MANUAL CONTENTS SECTION TITLE 1. Parts List 2. Specification 3. Installation Guide 4. Keypad (programming guide) 3millID acknowledges all copyrights and registered trademarks used by third parties. No affiliation is implied, or should be inferred, to the use of any tradename or reference to copyright material. Any reference to copyright material or registered trademarks within this document is used purely to depict or identify such material for the purpose of comment, description or comparison, and to assist in the evaluation of products or services described herein. UTJ-AV90 No part of this publication may be reproduced or translated into other languages or transmitted into a language used by data processing machines without the express written consent of 3millID. E&OE We do our best to provide accurate and reliable information at the time of publication, but due to continuous developments we cannot be held responsible for clerical errors, omissions or outdated information, and we reserve the right to amend, alter or withdraw such information, without notice. PAGE These devices comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. These devices contains: FCC ID: TCZ-10103751G1 EQUIPMENT ******* These RFID proximity readers comply with the essential requirements and relevant provisions of: EU Directive 2014/53/EC Together with information provided by suppliers and subcontractors, these devices comply with the requirements and relevant provisions of: EU Directive 2011/65/EC Images shown in this document are for illustrative purposes only. The features, colours, style and appearance may change without notice. © 3millID 100-02640-A This symbol on the product or on its packaging indicates that the product must not be disposed of with normal household waste. Instead, it is your responsibility to dispose of your waste equipment by arranging to return it to a designated collection point for the recycling of waste electrical and electronic equipment. By separating and recycling your waste equipment at the time of disposal you will help to conserve natural resources and ensure that the equipment is recycled in a manner that protects human health and the environment. EU Directive 2012/19/EC 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com 3M S-Gang Keypad 1. 2. MANUAL parts list 1 x reader MODULE 1 x reader BACKPLATE 1 x 3 x 10mm black cross-head securing screw + 66 - 35 specification up to 5yrs 10cm performance level for access control This product complies with the following UL294 Access Control Performance Levels: Destructive Attack Level I Line Security Level I Endurance Level IV Standby Power Level I See the UL Listed access control unit controller installation instructions for reader compatibility. UL Ref. Number ?????? environmental Operating Temperature Humidity Ingress Protection -35°C to +66°C 85 ±5% at 30 ±2°C IP65 Positioning Suitable for INDOOR and OUTDOOR use. electrical Power supply 76mm 3.0 inches 135mA typical Data Voltage Rest >4Vdc / Active <1Vdc Data Output Wiegand, Clock & Data, Custom Outputs Indication 1 RGB LED + RGB illuminated keypad Sounder Integral speaker dimensions 120mm x 76mm x 21mm (4.7 x 3.0 x 0.8 inches) polymeric materials Potting compound Mouldings UL R/C (QMFZ2) UL746C wiring Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction. Recommended cable BELDEN 953x (or equivalent UL listed) - Wiegand BELDEN 9502 (or equivalent UL listed) - RS485 All cable and wiring must be Listed and suitable for use. Cable length must not exceed 30 metres maximum (98.5 feet) for UL not less than 26 AWG (0.24mm²) Minimum permissible wire size connections Screw terminal 120mm 4.7 inches Current Cable length (All readers in this series use this terminal connection) 10 100-02640-A 21mm 0.8 inch Power is to be provided by a UL294 Listed, low-voltage Class 2 power limited supply or control panel, capable of 4 hours standby. +10Vdc to +16Vdc Voltage © 3millID (-31°F to + 151°F) (86 ±3°F) (not evaluated by UL) 0V +Vdc DATA1/CLK DATA0/DAT GREEN RED Buzzer TMPR/CP RS485RS485+ Supply voltage ground Supply voltage (+10Vdc to +16Vdc) Wiegand or Clock/Data output Wiegand or Clock/Data output Green LED control input Red LED control input Buzzer control input Tamper or Card Present output RS485 Bus RS485 Bus 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com 3M S-Gang Keypad 3. MANUAL installation guide Remove module securement screw. Lever bottom edge of reader module away Fix reader BACKPLATE to a plain surface finish, using suitable screw fixings from the backplate, and lift up. having a diameter no greater than 4mm (0.15 inch). If printed full scale, you may use the drawing below as a fixing template. MEASURE and CHECK DIMENSIONS before use. NOTE: Mounting this reader on (or near) metal may impair the read range of the unit. 53.0mm 2.1 inches Fixing holes - 4mm 53.0mm 2.1 inches 83.3mm (US) 3.3 inches maximum diameter. centreline BACKPLATE Once the backplate secured, make is wire connections to the reader, in accordance with the screw terminal connections shown on Page 3 of this document and your control requirements. panel Ensure the cable does not impair or 15mm 0.6 inch prevent the reader module being secured. 60.3mm (UK/EU) 2.4 inches Fasten the reader module, ensuring the top-edge fixings engage correctly with the recesses at the top of the backplate. Swing the bottom edge of the module down and forward until you feel the unit ‘snap’ shut. Secure the module to the backplate using the M3x10mm screw supplied. If required, you may opt to use a security screw to the sizes shown here. © 3millID 100-02640-A Following installation, it is recommended the access control system and control units are subjected to a maintenance and operational test procedure. TEST COMPLETE SYSTEM AT LEAST ONCE A YEAR 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com 3M S-Gang Keypad 4. MANUAL keypad programming guide The following instructions give a step-by-step procedure for accessing the many features supported by this reader. KEYPAD SECTION TITLE *00 LOG ON *01 DESCRIPTION page - entering programming mode PIN MODE - set PIN mode (output) *02 KEY TONE - set audible tone on key press *03 CARD TONE - set audible tone on card *04 PROX READ - set proximity reading *05 RX00 LED - set LED colour configuration *06 SITE CODE - set site code embedding *07 RX00 COLOUR - set LED quiescent colour *10 RX00 HID - set reader to read HID® *11 RX00 EM - set reader to read EM *12 RX00 CASI - set reader to read CASI *13 RX00 AWID - set reader to read AWID 10 *14 RX00 KANTECH - set reader to read KANTECH 10 *15 RX00 FARPOINTE - set reader to read FARPOINTE 10 *20 RX80 MIFARE - set reader to read MIFARE® 11 *21 RX80 ENDIAN - set reader to read ENDIAN 11 *30 RX90 DESFIRE - set reader to read DESFire® 11 *98 SET PIN - set engineer’s PIN code 12 *99 LOG OFF - exit configuration mode 12 ‘MIFARE’, ‘MIFARE Classic’ and ‘MIFARE DESFire EV1’ are trademarks of NXP B.V. © 3millID 100-02640-A 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com 3M S-Gang Keypad 4. MANUAL keypad programming guide The following instructions give a step-by-step procedure for accessing the many features supported by this reader. *00 LOG-ON PIN CODES *00nnnn# example entering ‘PROGRAMMING MODE’ Before you can configure the reader you MUST enter programming mode by using this command. You must enter the correct four-digit security PIN for the reader. The factory default PIN = 1234 ..... 26-bit WIEGAND (buffered) ..... 32-bit WIEGAND (buffered) ..... 34-bit WIEGAND (buffered) To place a FACTORY-DEFAULT reader into programming mode, you must enter: *001234# NOTE: To change the log-on PIN code, see: Section *98 on Page 12 of this document. NOTE: To exit PROGRAMMING MODE see: Section *99 on Page 12 of this document. You must correctly exit this mode to save any changes to values or settings you may have made. After entering programming mode, the reader will time out after approximately 30 seconds if no keys are pressed for that duration. Any changes you may have made to values or settings will be lost. *01 PIN mode PIN CODES *01n# *010# *011# *012# *013# *014# *015# *016# *017# *018# *019# example © 3millID 100-02640-A set PIN mode (output) This programming command allows you to configure how the reader handles keypad data. The reader is capable of keypad data output in a number of industry-standard formats. The following modes are supported: ..... DISABLED (NO keypad output) ..... HID 4-bit WIEGAND (factory default) ..... Dorado 8-bit WIEGAND (compatible with INDALA) ..... Mercury 8-bit WEIGAND burst ..... 1 digit CLOCK and DATA ..... Dorado 8-bit burst ..... 8 digit CLOCK and DATA (buffered) To set the reader to buffer keystrokes and output them in the industry-standard 26-bit WIEGAND format, you should enter: *017# once the reader has been placed into programming mode. 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com 3M S-Gang Keypad 4. MANUAL keypad programming guide The following instructions give a step-by-step procedure for accessing the many features supported by this reader. *02 KEY TONE PIN CODES *02n# *020# ..... *021# ..... example *03 CARD TONE PIN CODES *03n# *030# ..... *031# ..... example *04 PROX READ PIN CODES *04n# set AUDIBLE TONE on KEY PRESS During the entry of a buffered PIN you have the option of making the reader issue a confirmation beep or an error (triple-beep) on entering the PIN. DISABLE (NO audio tone) (factory default) ENABLE (audible tone on PIN entry) example © 3millID 100-02640-A To ENABLE the buzzer, enter: *021# once the reader has been placed into programming mode. set AUDIBLE TONE on CARD During the entry of a buffered PIN you have the option of making the reader issue a confirmation beep or an error (triple-beep) on presenting a CARD. DISABLE (NO audio tone) (factory default) ENABLE (audible tone on presenting a card) To ENABLE audio tone, enter: *031# once the reader has been placed into programming mode. set PROXIMITY READING This programming command allows you to disable transmission of the proximity card data from the reader. The reader will still beep to indicate that it has read the card. *040# ..... *041# ..... DISABLE (data will NOT be sent) ENABLE (data WILL be sent) (factory default) To DISABLE transmission of the card data, enter: *040# once the reader has been placed into programming mode. 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com 3M S-Gang Keypad 4. MANUAL keypad programming guide The following instructions give a step-by-step procedure for accessing the many features supported by this reader. *05 RX00 LED PIN CODES *05n# *050# *051# *052# *053# *054# example *06 SITE CODE PIN CODES *06nnnnn# example *07 RX00 COLOUR PIN CODES *07n# *070# *071# *072# *073# *074# *075# *076# *077# example © 3millID 100-02640-A set LED COLOUR CONFIGURATION The LED may be configured to the following modes: ..... RX standard LED configuration ..... RX Demo ..... White ..... Turquoise ..... OFF (LED disabled when in idle mode) ..... RX buzzer ..... RX AWE (excluded from documentation) ..... RX MPS (excluded from documentation) To set RX Demo enter: *051# once the reader has been placed into programming mode. set SITE CODE EMBEDDING This option allows the SITE CODE number to be combined with the card number read from the card and sent as the complete card info’ message. The unit accepts site codes from 0 to 65535 - however the maximum valid value depends on the output format. To embed SITE CODE ‘123’ enter: *0600123# reader has been placed into programming mode. once the set LED QUIESCENT COLOUR The LED may be configured to the following standard colours. ..... Blue ..... Magenta ..... Yellow ..... Orange ..... Red To set the LED to TURQUOISE enter: *076# reader has been placed into programming mode. once the 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com 3M S-Gang Keypad 4. MANUAL keypad programming guide The following instructions give a step-by-step procedure for accessing the many features supported by this reader. *10 RX00 HID set reader to read ‘HID®’ PIN CODES *10n# Configure reader to read ‘HID®’ proximity cards. *100# ..... *101# ..... *102# ..... example *11 RX00 EM PIN CODES *11n# *110# *111# *112# *113# *114# example *12 RX00 CASI PIN CODES *12n# *120# *121# *122# *123# *124# example © 3millID 100-02640-A DISABLE function WIEGAND Pass Through Clock and Data To set WIEGAND Pass Through enter: *101# reader has been placed into programming mode. once the set reader to read ‘EM’ Configure reader to read ‘EM’ proximity cards. ..... DISABLE function ..... 26-bit WIEGAND ..... 34-bit WIEGAND ..... 42-bit WIEGAND ..... Clock and Data To set 26-bit WIEGAND enter: *111# once the reader has been placed into programming mode. set reader to read ‘CASI’ Configure reader to read ‘CASI’ proximity cards. ..... DISABLE function ..... 4001 40-bit WIEGAND ..... 4002 40-bit WIEGAND ..... Extended 4001 40-bit WIEGAND ..... Extended 4002 40-bit WIEGAND To set 4001 40-bit WIEGAND enter: *121# reader has been placed into programming mode. once the 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com 3M S-Gang Keypad 4. 10 MANUAL keypad programming guide The following instructions give a step-by-step procedure for accessing the many features supported by this reader. *13 RX00 AWID PIN CODES *13n# *130# ..... *131# ..... example *14 RX00 KANTECH PIN CODES *14n# *140# ..... *141# ..... *142# ..... example *15 RX00 FARPOINTE PIN CODES *15n# *150# ..... *151# ..... example © 3millID 100-02640-A set reader to read ‘AWID’ Configure reader to read ‘AWID’ proximity cards. DISABLE function ENABLE function To set ENABLE ‘AWID’ function, enter: *131# reader has been placed into programming mode. once the set reader to read ‘KANTECH’ Configure reader to read ‘KANTECH®’ proximity cards. DISABLE function 26-bit WIEGAND 39-bit XSF WIEGAND To set KANTECH 26-bit Wiegand enter: *141# reader has been placed into programming mode. once the set reader to read ‘FARPOINTE’ Configure reader to read ‘FARPOINTE®’ proximity cards. DISABLE function ENABLE function To enable Farpointe enter: *151# once the reader has been placed into programming mode. 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com 3M S-Gang Keypad 4. 11 MANUAL keypad programming guide The following instructions give a step-by-step procedure for accessing the many features supported by this reader. *20 RX80 MIFARE set reader to read ‘MIFARE®’ PIN CODES *20n# *200# *201# *202# *203# *204# *205# Configure reader to read ‘MIFARE®’ proximity cards. ..... DISABLE function ..... 26-bit WIEGAND ..... 32-bit WIEGAND ..... 34-bit WIEGAND ..... Clock and Data ..... MIFARE® SE example *21 RX80 ENDIAN PIN CODES *21n# *210# ..... *211# ..... example *30 RX90 DESFire PIN CODES *30n# *300# ..... *301# ..... example © 3millID 100-02640-A To set 26-bit Wiegand enter: *201# been placed into programming mode. once the reader has set reader to read ‘ENDIAN’ Configure reader to read ‘ENDIAN’ proximity cards. Big ENDIAN Little ENDIAN To set Little ENDIAN enter: *211# once the reader has been placed into programming mode. set reader to read ‘DESFire®’ Configure reader to read ‘DESFire®’ proximity cards. DISABLE function ENABLE function To ENABLE function, enter: *301# once the reader has been placed into programming mode. 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com 3M S-Gang Keypad 4. 12 MANUAL keypad programming guide The following instructions give a step-by-step procedure for accessing the many features supported by this reader. *98 set PIN PIN CODES *98oooonnnn# set engineer’s PIN code Use this code to change the factory default PIN to your own 4 digit engineer’s PIN setting. The factory default PIN = 1234 oooo ..... nnnn ..... NOTE: WARNING: example current PIN (4 digits) (factory default = 1234) engineer’s PIN setting (4 digits) Remember to keep a record of your new PIN. If you forget your PIN setting, you will need to contact your INSTALLER or SUPPLIER to obtain a RESET code. To set your new PIN to 6789 enter: *9812346789# once the reader has been placed into programming mode. After entering programming mode, the reader will time out after approximately 30 seconds if no keys are pressed for that duration. Any changes you may have made to values or settings will be lost. *99 LOG OFF PIN CODES *99# NOTE: example EXIT CONFIGURATION MODE Use this code to EXIT the CONFIGURATION MODE of the reader. You MUST use this code to ensure any changes to values or settings you may have made, are safely SAVED to the reader. Enter: *99# to exit CONFIGURATION MODE (and save any settings made). After entering programming mode, the reader will time out after approximately 30 seconds if no keys are pressed for that duration. Any changes you may have made to values or settings will be lost. 4. © 3millID 100-02640-A END of keypad programming guide 3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129 www.3millid.com +1 303 475 4972 sales@3millid.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf Linearized : Yes Create Date : 2016:12:05 11:08:14Z Creator : (Xara.com) Modify Date : 2016:12:05 11:08:14Z Producer : (Xara.com) PDF export 8,0,0,6 Page Mode : UseNone Page Count : 12 PDF Version : 1.4EXIF Metadata provided by EXIF.tools