Third Millennium Systems AV90 Access Control Reader, Model AV90 User Manual

Third Millennium Systems Ltd. Access Control Reader, Model AV90

User manual

Download: Third Millennium Systems AV90 Access Control Reader, Model AV90 User Manual
Mirror Download [FCC.gov]Third Millennium Systems AV90 Access Control Reader, Model AV90 User Manual
Document ID3220280
Application ID7IHpUMk7DgRig9cKxGuMyA==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize147.56kB (1844535 bits)
Date Submitted2016-12-07 00:00:00
Date Available2016-12-07 00:00:00
Creation Date2016-12-05 11:06:32
Producing Software(Xara.com) PDF export 8,0,0,6
Document Lastmod2016-12-05 11:06:32
Document TitleUser manual
Document Creator(Xara.com)

3M
S-Gang
style or technology - now you can have both
MANUAL
Product Features
Designed to embrace cutting-edge RFID
technologies in a stylish and innovative
package, this advanced access control reader
offers a refreshing breakthrough in the access
security marketplace. Shaped in a sleek singlegang style design, the reader may be mounted to
most plain wall finishes, or directly to a US electrical
backbox.
This powerfully secure and innovative reader has a beautifully
clean aesthetic, and a bright RGB LED that can be applied to many
applications such as colour coded access levels, migration status or mood lighting.
The reader housing is moulded using tough polycarbonate plastic, and includes a shadow-line
backplate, a subtle and simple mechanical design feature that makes the reader, when fixed,
appear to float against the wall.
•
•
125KHz
13.56MHz
•
Bluetooth LE
•
•
•
•
•
•
•
Black textured moulding
Slim profile
RGB LED
Fully encapsulated electronics
Wide range of output formats
5 year limited warranty
Read range up to 10cm (4 inches)
Proximity
Smart Contactless
Images shown in this document are for illustrative purposes only. The features, colours, style and appearance may change without notice.
© 3millID
100-02639-A
3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129
www.3millid.com
+1 303 475 4972
sales@3millid.com
3M
S-Gang
style or technology - now you can have both
MANUAL
CONTENTS
SECTION
TITLE
1.
Parts List
2.
Specification
3.
Installation Guide
3millID
acknowledges all copyrights and registered trademarks used by third parties. No affiliation is implied, or should be
inferred, to the use of any tradename or reference to copyright material.
Any reference to copyright material or registered trademarks within this document is used purely to depict or identify such
material for the purpose of comment, description or comparison, and to assist in the evaluation of products or services
described herein.
UTJ-AV90
No part of this publication may be reproduced or translated into other languages or transmitted into a language used by data
processing machines without the express written consent of 3millID.
E&OE
We do our best to provide accurate and reliable information at the time of publication, but due to continuous developments we
cannot be held responsible for clerical errors, omissions or outdated information, and we reserve the right to amend, alter or
withdraw such information, without notice.
PAGE
These devices comply with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired
operation.
Any changes or modifications not expressly approved by
the party responsible for compliance could void the user’s
authority to operate the equipment.
These devices contains: FCC ID: TCZ-10103751G1
EQUIPMENT
*******
These RFID proximity readers comply with the essential
requirements and relevant provisions of:
EU Directive 2014/53/EC
Together with information provided by suppliers and
subcontractors, these devices comply with the
requirements and relevant provisions of:
EU Directive 2011/65/EC
Images shown in this document are for illustrative purposes only. The features, colours, style and appearance may change without notice.
© 3millID
100-02639-A
This symbol on the product or on its packaging indicates
that the product must not be disposed of with normal
household waste. Instead, it is your responsibility to
dispose of your waste equipment by arranging to return
it to a designated collection point for the recycling of
waste electrical and electronic equipment. By separating
and recycling your waste equipment at the time of
disposal you will help to conserve natural resources and
ensure that the equipment is recycled in a manner that
protects human health and the environment.
EU Directive 2012/19/EC
3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129
www.3millid.com
+1 303 475 4972
sales@3millid.com
3M
S-Gang
1.
2.
MANUAL
parts list
1 x
reader MODULE
1 x
reader BACKPLATE
1 x
3 x 10mm black cross-head securing screw
+ 66
- 35
specification
up to
5yrs
10cm
performance level for access control
This product complies with the following UL294 Access Control Performance Levels:
Destructive Attack
Level I
Line Security
Level I
Endurance
Level IV
Standby Power
Level I
See the UL Listed access control unit controller installation instructions for reader
compatibility.
UL Ref. Number
??????
environmental
Operating Temperature
Humidity
Ingress Protection
-35°C to +66°C
85 ±5% at 30 ±2°C
IP65
Positioning
Suitable for INDOOR and OUTDOOR use.
electrical
Power supply
76mm
3.0 inches
70mA typical
Data Voltage
Rest >4Vdc / Active <1Vdc
120mm
4.7 inches
Current
Data Output
Wiegand, Clock & Data, Custom Outputs
Indication
1 RGB LED
Sounder
Integral speaker
dimensions
120mm x 76mm x 21mm (4.7 x 3.0 x 0.8 inches)
polymeric materials
Potting compound
Mouldings
UL R/C (QMFZ2)
UL746C
wiring
Wiring methods shall be in accordance with the
National Electrical Code (ANSI/NFPA70), local
codes, and the authorities having jurisdiction.
Recommended cable
BELDEN 953x (or equivalent UL listed) - Wiegand
BELDEN 9502 (or equivalent UL listed) - RS485
All cable and wiring must be Listed and suitable for use.
Cable length must not exceed 30 metres maximum
(98.5 feet) for UL
not less than 26 AWG (0.24mm²)
Cable length
Minimum permissible wire size
connections
Screw terminal
(All readers in this series use this terminal connection)
10
100-02639-A
21mm
0.8 inch
Power is to be provided by a UL294 Listed, low-voltage
Class 2 power limited supply or control panel, capable
of 4 hours standby.
+10Vdc to +16Vdc
Voltage
© 3millID
(-31°F to + 151°F)
(86 ±3°F)
(not evaluated by UL)
0V
+Vdc
DATA1/CLK
DATA0/DAT
GREEN
RED
Buzzer
TMPR/CP
RS485RS485+
Supply voltage ground
Supply voltage (+10Vdc to +16Vdc)
Wiegand or Clock/Data output
Wiegand or Clock/Data output
Green LED control input
Red LED control input
Buzzer control input
Tamper or Card Present output
RS485 Bus
RS485 Bus
3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129
www.3millid.com
+1 303 475 4972
sales@3millid.com
3M
S-Gang
3.
MANUAL
installation guide
Remove module securement screw. Lever bottom edge of reader module away
Fix reader BACKPLATE to a plain surface finish, using suitable screw fixings
from the backplate, and lift up.
having a diameter no greater than 4mm (0.15 inch).
If printed full scale, you may use the drawing below as a fixing template.
MEASURE and CHECK DIMENSIONS before use.
NOTE:
Mounting this reader on (or near) metal may impair the read range of the unit.
53.0mm
2.1 inches
Fixing holes - 4mm
maximum diameter.
53.0mm
2.1 inches
83.3mm (US)
3.3 inches
centre
line
BACKPLATE
Once
the
backplate
secured,
make
is
wire
connections to the reader, in
accordance with the screw
terminal connections shown
on Page 3 of this document
and
your
control
requirements.
panel
Ensure
the
cable does not impair or
15mm
0.6 inch
prevent the reader module
being secured.
60.3mm (UK/EU)
2.4 inches
Fasten the reader module, ensuring the top-edge fixings engage correctly with the
recesses at the top of the backplate. Swing the bottom edge of the module down
and forward until you feel the unit ‘snap’ shut.
Secure the module to the backplate using the M3x10mm screw supplied.
If required, you may opt to use a security screw to the sizes shown here.
© 3millID
100-02639-A
Following installation, it is recommended the access control system and control
units are subjected to a maintenance and operational test procedure.
TEST COMPLETE SYSTEM AT LEAST ONCE A YEAR
3millID 9249 S. Broadway Building #200 Suite 826 Highlands Ranch CO 80129
www.3millid.com
+1 303 475 4972
sales@3millid.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
Linearized                      : Yes
Create Date                     : 2016:12:05 11:06:32Z
Creator                         :  (Xara.com)
Modify Date                     : 2016:12:05 11:06:32Z
Producer                        :  (Xara.com) PDF export 8,0,0,6
Page Mode                       : UseNone
Page Count                      : 4
PDF Version                     : 1.4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UTJ-AV90

Navigation menu