Thomson Broadcast and Multimedia ULT-1K10K2 UHF Digital transmitter, for use with MediaFlo User Manual PREIMPAP
Thomson Broadcast & Multimedia, Inc. UHF Digital transmitter, for use with MediaFlo PREIMPAP
Contents
User Manual part 1
Digital Liquid Cooled UHF TV
Equipment
5K2 DD, MEDIAFLO SIRIUS
12089
Operation and User Manual
45321648.01
NumĂŠro / Number
: 33 (1) 34.90.32.55
: hotline@thales-bm.com
108
Doc.
Rev.
Langu.
Checked
27/06/2006
9932 V2
Table of content
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
1.
Exploitation .......................................................................................................6
1.1.
Navigating the PCLwindows ......................................................................... 6
1.2.
Where to find operational parameters........................................................ 11
1.2.1.
Transmitter configuration parameters........................................................ 11
1.2.2.
Transmitter operational parameters .......................................................... 12
1.2.3.
Adjustable parameters............................................................................... 12
1.2.4.
Measurements ........................................................................................... 13
1.2.5.
Status conditions of main transmitter elements......................................... 14
1.3.
Procedure for changing configuration parameters................................... 15
1.4.
Procedure for inserting Ethernet network parameters ............................. 19
1.5.
Procedure to activate "SNMP" or "WEB" agent ....................................... 21
1.6.
Procedures for adjusting or changing operational parameters............... 23
1.6.1.
Procedure to call the maintenance mode .................................................. 23
1.6.2.
Procedure for adjusting the calibrated transmitter power.......................... 23
1.6.3.
Procedure for adjusting the required transmitter power ............................ 24
1.6.4.
Procedure for changing the modulator input ............................................. 25
1.6.5.
Procedure for changing the configuration of the Adaptation parameters
(ALE and LUT) ........................................................................................... 26
1.6.6.
Procedure for changing the configuration parameters of the OLDC card . 26
1.6.7.
Procedure for changing the frequency of the RF synthesiser ................... 27
1.6.8.
Procedure for changing ripple and shoulder threshold settings in
maintenance mode .................................................................................... 27
1.6.9.
Procedure for changing the threshold settings of the OLDC card............. 28
1.6.10.
Procedure for changing RF digital power threshold settings for triggering
alarm and fault signals............................................................................... 28
1.6.11.
Procedures for changing quality thresholds .............................................. 29
1.6.12.
Procedure for setting the time and the date .............................................. 29
1.7.
Procedure for changing the PCL password............................................... 30
1.8.
Procedures for changing a status condition or transmitter operating
mode .............................................................................................................. 31
1.8.1.
Procedure for lock to unlock the PCL ........................................................ 31
1.8.2.
Selection of transmitter operation mode.................................................... 32
1.8.3.
Manuel change over of exciter .................................................................. 32
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
ii
Rev.
Langu.
27/06/2006
Page
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
1.9.
2.
1.8.4.
Selection of exciter changeover mode ...................................................... 33
1.8.5.
Selection of user interface ......................................................................... 33
Procedure for switching on and off ............................................................ 34
1.9.1.
Switching on-air and switching off-air ........................................................ 34
1.9.2.
Switching the reserve exciter on and off.................................................... 34
1.10.
Procedure for adjusting PCL screen contrast ........................................... 35
1.11.
Procedure for transmitter reset................................................................... 36
1.12.
Procedure for using maintenance information.......................................... 37
1.12.1.
Display of faults and status conditions ...................................................... 37
1.12.2.
Access to logbook...................................................................................... 39
Use of commands and description of indicators .........................................40
2.1.
Use and description of control panel screens........................................... 40
2.1.1.
Outline........................................................................................................ 40
2.1.2.
Installation windows................................................................................... 42
2.1.3.
Warning windows....................................................................................... 53
2.1.4.
"TRANSMITTER STATUS" window .......................................................... 57
2.1.5.
"STATUS" window ..................................................................................... 61
2.1.6.
"IDENTIFICATION" window....................................................................... 63
2.1.7.
"MODULATOR IDENTIFICATION, Type I" window .................................. 65
2.1.8.
"MODULATOR IDENTIFICATION, type II" window................................... 67
2.1.9.
"CONTROL Level 1" window ..................................................................... 69
2.1.10.
"CONTROL MAINT Level 2" window for Maintenance mode.................... 72
2.1.11.
"CONTROL MAINT Level 3" window for Maintenance mode.................... 74
2.1.12.
"CONTROL MAINT Level 4" window for Maintenance mode (MODAP
version ONLY) ........................................................................................... 76
2.1.13.
"CONTROL OPER Level 2" window for Normal Mode.............................. 78
2.1.14.
"NUMERICAL VALUE" window ................................................................. 80
2.1.15.
"RF LEVEL" window .................................................................................. 82
2.1.16.
"REQUIRED POWER" window.................................................................. 85
2.1.17.
"HOUR COUNTER" window...................................................................... 87
2.1.18.
DATE & TIME" window .............................................................................. 89
2.1.19.
"RF THRESHOLD" window ....................................................................... 91
2.1.20.
"QUALITY THRESHOLD SETTINGS" window ......................................... 93
2.1.21.
"COFDM or 8VSB PARAMETERS" window.............................................. 95
2.1.22.
"FLO 1 PARAMETERS" window ............................................................... 98
2.1.23.
"FLO 2 PARAMETERS" window ............................................................. 100
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
iii
Rev.
Langu.
27/06/2006
Page
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
2.1.24.
"MISCELLANEOUS" window................................................................... 102
2.1.25.
"LOGBOOK" window ............................................................................... 105
2.1.26.
"EXCITER Level 1" window, or "EXCITER PANEL" window, MODAP
version ONLY .......................................................................................... 107
2.1.27.
"EXCITER Level 2" window, MODAP version ONLY .............................. 111
2.1.28.
"EXCITER Level 1" window, or "EXCITER PANEL" window, SIRIUS
version ONLY .......................................................................................... 113
2.1.29.
"EXCITER Level 2" window, SIRIUS version ONLY ............................... 116
2.1.30.
"FLO 1 MODULATOR" window .............................................................. 119
2.1.31.
"FLO 2 MODULATOR" window .............................................................. 122
2.1.32.
"COFDM MODULATOR" window ............................................................ 124
2.1.33.
"ADAPT PARAMETERS" window ........................................................... 126
2.1.34.
"DASI STATUS" window.......................................................................... 129
2.1.35.
"OLDC STATUS" window, MODAP version ONLY ................................. 132
2.1.36.
"SETTINGS" window, SIRIUS version ONLY.......................................... 134
2.1.37.
"RESERVE ADAPTATIVITY SETTINGS" window, SIRIUS version ONLY
136
2.1.38.
"PREAMPLI SETTING" window, SIRIUS version ONLY......................... 138
2.1.39.
"AGC SETTING" window, SIRIUS version ONLY ................................... 140
2.1.40.
"LOCAL/IMAGE REJECT" window, SIRIUS version ONLY .................... 142
2.1.41.
"10 MHz ADJUSTEMENT" window, SIRIUS version ONLY ................... 144
2.1.42.
"LINEAR CORRECTION CALIBRATION" window, SIRIUS version ONLY
146
2.1.43.
"SFN DELAY" window ............................................................................. 148
2.1.44.
"MODULATOR CONFIG" window ........................................................... 150
2.1.45.
"MODULATOR STATUS" window ........................................................... 152
2.1.46.
"MODULATOR - MIP" window................................................................. 154
2.1.47.
"RF AMPLIFIERS" window, 6 current values (OPTIMUN / ULTIMATE
FAMILY) 155
2.1.48.
"RF AMPLIFIERS" window, 8 current values (OPTIMUM FAMILY ONLY)
157
2.1.49.
"PA LEVELS" window (OPTIMUM AND ULTIMATE FAMILIES ONLY) . 159
2.1.50.
"AIR INTERLOCK" window (OPTIMUM AND ULTIMATE FAMILIES ONLY)
161
2.1.51.
"LIQUIDE INTERLOCK" window (OPTIMUM AND ULTIMATE FAMILIES
ONLY) 164
2.1.52.
"POWER SUPPLY" window (OPTIMUM AND ULTIMATE FAMILIES
ONLY) 166
2.1.53.
"AFFINITY" window (AFFINITY FAMILY ONLY)..................................... 168
2.1.54.
"GO HOME AND VIEW INSTALL. PARAMETERS" window .................. 170
2.1.55.
"VIEW TRANSMITTER INTERFACE INSTALLATION PARAMETERS"
window 173
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
iv
Rev.
Langu.
27/06/2006
Page
2.2.
2.1.56.
"VIEW CABINET CONFIGURATION INSTALLATION PARAMETERS"
window 174
2.1.57.
"VIEW ADAPT INSTALLATION PARAMETERS" window ...................... 175
2.1.58.
"VIEW ETHERNET INSTALLATION PARAMETERS" window............... 177
2.1.59.
Navigating the PCL windows ................................................................... 179
Exciter, SIRIUS............................................................................................ 184
2.2.1.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
2.3.
2.4.
2.5.
2.6.
2.7.
Front panel............................................................................................... 184
Local control panel..................................................................................... 186
2.3.1.
Indicator lamps and message displays.................................................... 186
2.3.2.
Adjustment controls ................................................................................. 186
2.3.3.
Test points ............................................................................................... 186
TH860 CPU Card ......................................................................................... 187
2.4.1.
Indicator lamps and message displays.................................................... 187
2.4.2.
Controls.................................................................................................... 187
RF amplifier unit ......................................................................................... 188
2.5.1.
Indicator lamps and message displays.................................................... 188
2.5.2.
Test points ............................................................................................... 189
2.5.3.
Adjustment controls ................................................................................. 189
Power supply unit....................................................................................... 190
2.6.1.
Using the commands ............................................................................... 190
2.6.2.
Indicator lamps and message displays.................................................... 190
2.6.3.
Test points ............................................................................................... 190
2.6.4.
Adjustment controls ................................................................................. 190
860 Cabinet Mains distribution ................................................................. 191
2.7.1.
Indicator lamps and message displays.................................................... 191
2.7.2.
Test points and adjustment controls........................................................ 191
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1. Exploitation
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
1.1. Navigating the PCLwindows
Figure 1 : Navigation in tactile screen windows (1/5)
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
6 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Exploitation
Figure 2 : Navigation in tactile screen windows (2/5)
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
7 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Exploitation
Figure 3 : Navigation in tactile screen windows (3/5)
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
8 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Exploitation
Figure 4 :: Navigation in tactile screen windows (4/5)
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
9 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Exploitation
Figure 5 : Navigation in tactile screen windows (5/5)
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
10 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.2. Where to find operational parameters
The following tables give the titles of the various PCL windows in which the various operational
parameters available to the operator can be found. The commands for accessing these windows are
given in other paragraph.
1.2.1.
Transmitter configuration parameters
PARAMETERS
PCL WINDOWS
RF synthesiser frequency
"INSTALLATION PARAMETERS Level 1" window
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
"GO HOME AND VIEW INSTALLATION
PARAMETERS" window
"CONTROL MAINT Level 3" window
Frequency range (VHF/UHF)
"INSTALLATION PARAMETERS Level 1" window
Maximum power
"GO HOME AND VIEW INSTALLATION
PARAMETERS" window
Calibrated power
Cooling type of the transmitter
Transmitter type (Simple Drive, Double Drive, Passive
Reserve, Active Reserve, N+1)
Modulation type of the transmitter (Analog /Digital)
Language selected
Type of display used (dB or %)
Type of remote operation (via serial link or hard wired)
Type of protocol operation for remote control (JBUS or
ASCII)
Transmitter Identification number with RS232 / RS 485
Type of bay used,
"TRANSMITTER INTERFACE INSTALLATION
PARAMETERS" window
"VIEW TRANSMITTER INTERFACE INSTALLATION
PARAMETERS " window
"CABINET CONFIGURATION PARAMETERS" window
Current measurement number by amplifier unit
Amplifier number detected by cabinet
"VIEW CABINET CONFIGURATION INSTALLATION
PARAMETERS" window
Amplifier location in each cabinet
"LOCATION AMPLIFIER " window
OLDC parameters (1)
"ADAPT INSTALLATION PARAMETERS" window
DASI parameters (1)
"VIEW ADAPT INSTALLATION PARAMETERS " window
ADAPT parameters
Type of modulator (COFDM / 8VSB)
Web activation code
"ETHERNET INSTALLATION PARAMETERS" window
SNMP activation code
"VIEW ETHERNET INSTALLATION PARAMETERS "
window
Network administrator configuration (IP address, subnet mask number)
Quality thresholds used for the notation of the
parameters power, shoulder and ripple
ATSC parameters***
"QUALITY THRESHOLD SETTINGS" window
"COFDM or 8VSB PARAMETERS" window
COFDM parameters**
SFN data**
Mediaflo modulator parameters ****
(General / Timing / Data SRC / Clock / Input)
(Modulation / channalizer)
45321648.01
NumĂŠro / Number
"FLO 1 PARAMETERS" window and
"FLO 2 PARAMETERS" window
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
11 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
PARAMETERS
PCL WINDOWS
Mediaflo modulator parameters ****
Current ADAPT parameters
"ADAPT PARAMETERS" window
COFDM current parameters**
"MODULATOR CONFIGURATION" window
MediaFLO current parameters****
"FLO 1 MODULATOR" window and
"FLO 2 MODULATOR" window
SFN current delays**
"SFN DELAYS" window
** Parameters used in DVB-T Transmitters only.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
*** Parameters used in ATSC Transmitters only.
**** Parameters used in Mediaflo Transmitters only.
(1) MODAP version only
1.2.2.
Transmitter operational parameters
PARAMETERS
PCL WINDOWS
Current operating mode (maintenance mode or normal
mode)
"TRANSMITTER STATUS" window
"STATUS" window
"CONTROL" window
PCL control â unlocked or locked
"STATUS" window
"Unlock" indicator lamp
Correction and transmitter operating mode (Fixed or
adaptative / Mute or Not Mute / PRBS or Mute)
"MISCELLANEOUS" window
Last three faults to appear
"STATUS" window
Selected User interface
"CONTROL MAINT Level 1" window
Selected exciter *
"TRANSMITTER STATUS" window
"EXCITER Level 1" window
Selected mode for exciter changeover *
Status of automatic exciter changeover * (Done, Not
done, impossible)
Selected mode for the reflected (reserve) power control
"TRANSMITTER STATUS" window
Selected mode for control gain of the transmitter (2)
"GO HOME" status
"AGC SETTING" window
"GO HOME AND VIEW INSTALLATION PARAMETERS"
window
"Go Home" indicator lamp
Actual transmitter on-air time since going into service
"HOUR COUNTER" window
*: Only in Double Drive Version
(2): SIRIUS version only
1.2.3.
Adjustable parameters
PARAMETERS
PCL WINDOWS
Amount of power reduction
"REQUIRED POWER" window
Calibrated power
"INSTALLATION PARAMETERS Level 1" window
High level Power alarm threshold
ÂŤRF THRESHOLDÂť window
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
12 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
PARAMETERS
PCL WINDOWS
Low level Power alarm threshold
Fault power threshold
"CONTROL MAINT Level 3" window
Ripple threshold for EXCITER correction
Shoulder threshold for EXCITER correction
Group Delay threshold for EXCITER correction (3)
MGC gain value (2)
"AGC SETTING" window
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Limitor gain value (2)
Adaptativity setting of the reserve exciter (2)
"RESERVE ADAPTATIVITY SETTINGS" window
Calibrates of the linear correction feedback for exciter (2)
"LINEAR CORRECTION CALIBRATION" window
Fault RF threshold for RF preamplifier (2)
"PREAMPLIFIER SETTINGS" window
Cancel the level of the local frequency and of the unwanted
lateral band (2)
"LOCAL/IMAGE REJECT" window
Adjust the value of the PLL 10Mhz frequency (2).
"10 MHz ADJUSTEMENT" window
Thresholds beyond which the OLDC performs a correction
(1)
"CONTROL MAINT Level 4" window
Quality thresholds used for the notation of the parameters
power, shoulder and ripple
"QUALITY THRESHOLD SETTINGS" window
Input signal type of the modulator
âCOFDM or 8VSB PARAMETERSâ window or
âFLO 1 PARAMETERSâ window
Clock type of the EXCITER
PID number values (3)
Timing Values (3)
Modulation parameters values (3)
Channelizer parameters values (3)
âFLO 1 PARAMETERSâ window and
âFLO 2 PARAMETERSâ window
(1) MODAP version only
(2) SIRIUS version only
(3) MediaFLO SIRIUS version only
1.2.4.
Measurements
PARAMETERS
PCL WINDOWS
RF power
"TRANSMITTER STATUS" window
Reflected power
RF power
"RF LEVEL" window
Reflected power
Antenna SWR
Shoulder level
Ripple level
Goup Delay level (3)
Transmitter gain
Overall quality assessment of the transmitter
Reference AGC value (2)
"AGC SETTING" window
Current AGC value (2)
AGC voltages for power amplifiers
âPA LEVELSâ window
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
13 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
PARAMETERS
PCL WINDOWS
RF transistor currents in the power amplifiers
"AMPLIFIERS" window
Central frequency rejection level (1)
"OLDC PARAMETERS" window
I/Q amplitude error level (1)
"OLDC PARAMETERS" window
(1) MODAP version only
(2) SIRIUS version only
(3) MediaFLO SIRIUS version only
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
1.2.5.
Status conditions of main transmitter elements
PARAMETERS
PCL WINDOWS
Status of exciter cards
"EXCITER PANEL" window
or
"EXCITER Level 2" window *
Status of reserve exciter (on or off) *
"CONTROL" window
Status of exciter signals
"EXCITER PANEL" window
or
"EXCITER Level 1" window *
Power amplifier status parameters
"AMPLIFIERS" window
Status of amplifier power supplies
"POWER SUPPLY" window
Status of protection system surveillance devices
"INTERLOCK" window
Status of the COFDM modulator**
"MODULATOR STATUS" window
or
"MODULATOR CONFIGURATION" window
Status of the 8VSB modulator***
"MODULATOR CONFIGURATION" window
Status of the MediaFLO configuration for the modulator
"MODULATOR FLO 1" window and "MODULATOR FLO 2"
window
Status of the ADAPT exciter
"ADAPT PARAMETERS" window
Status of the DASI card
âDASI STATUSâ window
Status of the OLDC card (1)
"OLDC STATUS" window
Status of the current gain control mode (2)
"AGC SETTING" window
* : Only in Double Drive Version.
** : Parameters used in DVB-T Transmitters only.
*** : Parameters used in ATSC Transmitters only.
(1) MODAP version only
(2) SIRIUS version only
(3) MediaFLO SIRIUS version only
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
14 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.3. Procedure for changing configuration parameters
The configuration parameters of the transmitter can be defined in the "INSTALLATION PARAMETERS
Level 1" window and "TRANSMITTER INTERFACE INSTALLATION PARAMETERS" window of the
PCL in installation mode.
The configuration parameters of the ADAPT exciter can be defined in the "ADAPT INSTALLATION
PARAMETERS" window of the PCL.
Nota :
âŚ
MODAP Version only
To set up a new parameter configuration of the modulator, the three corrections (ALE, LUT and OLDC) should be
set to the FIXED mode. The control keys can be defined in the "MISCELLANEOUS" windows and "CONTROL
MAINT Level 4" windows.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
âŚ
SIRIUS Version only
To set up a new parameter configuration of the modulator, the two corrections (ALE, and LUT) should be set to
the FIXED mode. The control keys can be defined in the "MISCELLANEOUS" windows.
The configuration parameters of the ETHERNET can be defined in the "ETHERNET INSTALLATION
PARAMETERS" window of the PCL.
DVB-T Transmitter configuration only:
⌠The configuration parameters of the COFDM can be defined in the "COFDM PARAMETTERS "
window of the PCL in maintenance MODE.
⌠The configuration parameters of the SFN can be defined in the "COFDM PARAMETERS" window
of the PCL in maintenance MODE.
DVB-T/H Transmitter configuration only:
⌠The configuration parameters of the COFDM can be defined in the "COFDM PARAMETTERS "
window and "DVB-H PARAMETTERS " window of the PCL in maintenance MODE.
MediaFLO Transmitter configuration only:
⌠The configuration parameters of the MediaFLO can be defined in the "FLO 1 PARAMETTERS"
window and " FLO 2 PARAMETTERS " window of the PCL in maintenance MODE.
The transmitter is configured in the:
⌠"INSTALLATION PARAMETERS Level 1",
⌠"TRANSMITTER INTERFACE INSTALLATION PARAMETERS",
⌠"ADAPT INSTALLATION PARAMETERS",
⌠"ETHERNET INSTALLATION PARAMETERS",
⌠"COFDM and SFN PARAMETERS" (if internal modulator) windows or "8VSB PARAMETERS"
windows or "FLO PARAMETERS" windows of the PCL.
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
15 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
The transmitter configuration can be defined via the tactile screen of PCL
ACTIONS
a)
To call up the
"INSTALLATION
PARAMETERS
Level 1" window
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Changing a
parameter:
RESULT
Set switch SW1, situated in ⌠The transmitter is switched to installation mode.
the
exciter/CPU
interconnection card on the ⌠The "INSTALLATION PARAMETERS Level 1"
window appears on the PCL and displays the
side of the sub-units behind
current transmitter configuration parameters.
the CPU card, such that the
dot is visible.
âŚ
Press reset button in front of CPU board.
âŚ
Press on the control keys corresponding âŚ
to the parameter to be changed and then
press repeatedly until the required
configuration appears.
The names of the available configurations for the
parameter in question will appear one after the
other on the control keys.
Special case of changing the external
synthesiser frequency:
IMPORTANT :
Before validating a new synthesiser
frequency, make sure that the settings of all
RF filters (ex. output RF filter, RF combiner,
...) are consistent with the new frequency.
âŚ
âŚ
Press on the "FREQ SYNTHE (Hz)" key,
âŚ
Enter the frequency value on the window âŚ
keyboard,
The value is displayed under the window title.
âŚ
Press "ENTER" to validate the entry.
âŚ
The "INSTALLATION PARAMETERS Level 1"
window appears.
âŚ
The new frequency value is displayed in the
"FREQ SYNTHE (Hz)" key.
âŚ
The "INSTALLATION PARAMETERS Level 1"
window appears.
Notes:
To cancel an entry press the "CANCEL" key.
The frequency must also be entered on the
thumb wheels. Alternatively, the thumb âŚ
wheels must be set to "0", except for the last
one (LSB), which must be set to "1".
Validation of the new
configuration
âŚ
Check that the data displayed in the âŚ
window are correct,
âŚ
Press the "VALID" key.
Cancelling the new
configuration
âŚ
Leave the installation mode
touching the "VALID" key.
Leaving the
installation mode
âŚ
Set switch SW1, situated in the âŚ
exciter/CPU interconnection card, such
that the dot is not visible and reset the
âŚ
CPU board.
âŚ
The "NUMERICAL VALUE" window appears.
The frequency value remains unchanged.
The transmitter stores the new configuration
parameters.
without
Reset the CPU board
The system is initialised with the new status
and operational parameters.
The "TRANSMITTER STATUS" window
appears and indicates that the system is in
normal operating mode.
The configuration parameters of the ADAPT exciter can be defined in the "ADAPT INSTALLATION
PARAMETERS" window of the PCL.
ACTIONS
RESULT
To call up the
"ADAPT
INSTALLATION
PARAMETERS"
window of the PCL
âŚ
Press "SCREEN NEXT" in the "INSTALL âŚ
CABINET
CONFIGURATION
PARAMETERS " window.
The "ADAPT INSTALLATION PARAMETERS"
window appears on the PCL and displays the
current DAP configuration parameters.
Changing a
parameter
âŚ
Press on the control keys corresponding âŚ
to the parameter to be changed and then
The names of the available configurations for the
parameter in question will appear one after the
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
16 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
ACTIONS
RESULT
press repeatedly until
configuration appears.
Calls up the
"INSTALLATION
PARAMETERS
Level 1" for validation
âŚ
the
required
other on the control keys.
Press successively on "INSTALL NEXT" âŚ
in the "INSTALLATION PARAMETERS"
windows.
The "INSTALLATION PARAMETERS Level 1"
window appears on the PCL.
Leaving the installation mode: When the PCL displays the "INSTALLATION PARAMETERS Level 1"
window, proceed as follows :
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
ACTIONS
Leaving the
installation mode
âŚ
âŚ
âŚ
RESULT
Press
the
valid
key
in
the âŚ
"INSTALLATION PARAMETERS Level 1"
window
âŚ
Set switch SW1, situated in the
exciter/CPU interconnection card, such
âŚ
that the dot is not visible.
The transmitter stores the new configuration
parameters.
The system is initialised with the new status and
operational parameters.
The "STATUS" window appears and indicates
that the system is in normal operating mode.
Reset the CPU board
The following operating quality threshold parameters of the ADAPT exciter can be defined in the
âQUALITY THRESHOLD SETTINGSâ window of the PCL :
⌠ripple threshold,
⌠shoulder threshold,
⌠power threshold.
ACTIONS
RESULT
To call up the
âQUALITY
THRESHOLD
SETTINGSâ window
of the PCL
âŚ
Press "QUALITY THRESHOLD" in the âŚ
"CONTROL MAINT Level 2" window.
To change a
parameter value
âŚ
Press on the control keys
parameter to be changed,
âŚ
Enter the required value on the window
keyboard,
âŚ
Press "ENTER" to validate the entry.
of
the âŚ
The "NUMERICAL VALUE" window appears.
âŚ
The value is displayed under the window title.
âŚ
The "CONTROL
appears.
âŚ
The new value is displayed on the parameter
control keys.
âŚ
The "CONTROL
appears.
âŚ
The value remains unchanged.
Note:
To cancel an entry press the "CANCEL" key.
45321648.01
NumĂŠro / Number
The âQUALITY THRESHOLD SETTINGSâ
window appears on the PCL and displays
the current threshold value.
108
Doc.
MAINT
MAINT
9932 V2
Checked
Rev.
Langu.
27/06/2006
Level
Level
2"
2"
window
window
17 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
The configuration parameters of the COFDM and SFN can be defined in the "COFDM
PARAMETERS" window of the PCL in maintenance mode.
These parameters are used in DVB-T Transmitters only.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
ACTIONS
RESULT
To call up the
"COFDM
PARAMETERS"
window of the PCL
âŚ
Press "MODUL" in the
MAINT Level 2" window.
"CONTROL âŚ
The "COFDM PARAMETERS" window
appears on the PCL and displays the
current COFDM configuration parameters.
Changing a COFDM
parameter
âŚ
Press on the control keys corresponding âŚ
to the parameter to be changed and then
press repeatedly until the required
configuration appears.
The names of the available configurations
for the parameter in question will appear
one after the other on the control keys.
âŚ
Press the valid key for validation the new
entry
âŚ
Press on the control key corresponding to âŚ
the parameter to be changed
The "NUMERICAL VALUE" window appears.
âŚ
Enter the required value on the window âŚ
keyboard
The value is displayed under the window title.
âŚ
Press "ENTER" to validate the entry.
âŚ
The "COFDM PARAMETERS" window appears.
The value is displayed on the parameter control
keys.
Changing a SFN
parameter
The configuration parameters of the MediaFLO can be defined in the "FLO1 PARAMETERS" window
and "FLO2 PARAMETERS" window of the PCL in maintenance mode.
These parameters are used in MediaFLO Transmitters only.
ACTIONS
RESULT
To call up the "FLO1
PARAMETERS"
window of the PCL
âŚ
Press "MODUL" in the
MAINT Level 2" window.
"CONTROL âŚ
The "FLO1 PARAMETERS" window appears on
the PCL and displays the current MediaFLO
configuration parameters (GENERAL / DATA
SRC / Clock / TIMING / INPUT).
To call up the "FLO2
PARAMETERS"
window of the PCL
âŚ
Press "NEXT SCREEN" in the "FLO1 âŚ
PARAMETERS" window.
The "FLO2 PARAMETERS" window appears on
the PCL and displays the current MediaFLO
configuration parameters. (MODULATION /
CHANNELIZER)
Changing a FLO
parameter
âŚ
Press on the control keys corresponding âŚ
to the parameter to be changed and then
press repeatedly until the required
configuration appears.
The names of the available configurations
for the parameter in question will appear
one after the other on the control keys.
âŚ
Press the valid key for validation the new
entry
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
18 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.4. Procedure for inserting Ethernet network parameters
The following parameters of the Ethernet network can be inserted in the âETHERNET INSTALLATION
PARAMETERSâ window of the PCL :
⌠IP address of the transmitter,
⌠Sub-net mask number,
⌠IP address of the gateway.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
ACTIONS
To call up the
"INSTALLATION
PARAMETERS
Level 1" window
âŚ
RESULT
Set switch SW1, situated in the âŚ
exciter/CPU interconnection card on the
side of the sub-units behind the CPU âŚ
card, such that the dot is visible.
The transmitter is switched to installation mode.
The "INSTALLATION PARAMETERS Level 1"
window appears on the PCL and displays the
current transmitter configuration parameters.
âŚ
Reset the CPU Board
To call up the
"ETHERNET
INSTALLATION
PARAMETERS"
window of the PCL
âŚ
Press
"INSTALL
NEXT"
in
the âŚ
"TRANSMITTER
INTERFACE
INSTALLATION
PARAMETERS",
"CABINET
CONFIGURATION
PARAMETERS" and "INSTALLATION
ADAPT PARAMETERS" window.
The
"ETHERNET
INSTALLATION
PARAMETERS" window appears on the PCL and
displays the current configuration parameters.
To insert a parameter
value
âŚ
Press on the control
parameter to be inserted,
the âŚ
The "NUMERICAL VALUE" window appears.
âŚ
Enter the required value on the window âŚ
keyboard,
The value is displayed under the window title.
âŚ
Press "ENTER" to validate the entry
âŚ
The "INSTALLATION PARAMETERS" window
appears. The value is displayed on the parameter
control keys.
keys
of
IMPORTANT :
â˘
The network parameter must be
furnished
by
your
network
administrator.
â˘
Setting bad parameter disturbs the
network.
Note:
Calls up the
"INSTALLATION
PARAMETERS
Level 1" for validation
âŚ
To cancel and entry press the "CANCEL" âŚ
key.
The
"INSTALLATION
window appears. The
unchanged.
âŚ
Press
"INSTALL
NEXT"
in
the âŚ
"ETHERNET
INSTALLATION
PARAMETERS" window.
The "INSTALLATION PARAMETERS Level 1"
window appears on the PCL.
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
PARAMETERS"
value remains
19 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
Leaving the installation mode: When the PCL displays the "INSTALLATION PARAMETERS Level 1"
window, proceed as follows :
ACTIONS
Leaving the
installation mode
âŚ
âŚ
Press
the
valid
key
in
the âŚ
"INSTALLATION PARAMETERS Level 1"
window
âŚ
Set switch SW1, situated in the
exciter/CPU interconnection card, such
âŚ
that the dot is not visible.
The transmitter stores the new configuration
parameters.
The system is initialised with the new status and
operational parameters.
The "STATUS" window appears and indicates
that the system is in normal operating mode.
Reset the CPU board
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
âŚ
RESULT
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
20 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.5. Procedure to activate "SNMP" or "WEB" agent
Each option is associated with an activation code. Each code is single and associated with one CPU
board. The identification number of the CPU board is given on the âETHERNET INSTALLATION
PARAMETERSâ window. With this number you can get the activation code of the SNMP agent and/or
WEB agent option (ask for THALES).
ACTIONS
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
To call up the
"INSTALLATION
PARAMETERS
Level 1" window
âŚ
RESULT
Set switch SW1, situated in the âŚ
exciter/CPU interconnection card on the
side of the sub-units behind the CPU âŚ
card, such that the dot is visible.
âŚ
Reset the CPU board
To call up the
"ETHERNET
INSTALLATION
PARAMETERS"
window of the PCL
âŚ
Press
"INSTALL
NEXT"
in
the âŚ
"TRANSMITTER
INTERFACE
INSTALLATION
PARAMETERS",
"CABINET
CONFIGURATION
PARAMETERS" and "INSTALLATION
ADAPT PARAMETERS" window.
Set the Ethernet
network parameters
âŚ
IP address of the transmitter,
âŚ
Sub-net mask number,
âŚ
IP address of the gateway.
âŚ
Refer to procedure § âProcedure for
inserting Ethernet network parametersâ
The transmitter is switched to installation mode.
The "INSTALLATION PARAMETERS Level 1"
window appears on the PCL and displays the
current transmitter configuration parameters.
The
"ETHERNET
INSTALLATION
PARAMETERS" window appears on the
PCL and displays the current configuration
parameters.
IMPORTANT :
To insert the
activation code
â˘
The NetWare parameters must be
furnished
by
your
network
administrator.
â˘
Setting bad parameter disturbs the
network.
âŚ
Press on the control keys of the code to âŚ
be inserted,
The "NUMERICAL VALUE" window appears.
âŚ
Enter the required value on the window âŚ
keyboard,
The value is displayed under the window title.
âŚ
Press "ENTER" to validate the entry.
âŚ
The "INSTALLATION PARAMETERS" window
appears.
IMPORTANT :
â˘
âŚ
Enter a bad code leads the control
âŚ
keys display to cone back to â0â.
The value is displayed on the control keys.
The "INSTALLATION PARAMETERS" window
appears.
Note:
To cancel and entry press the "CANCEL" âŚ
key.
Calls up the
"INSTALLATION
PARAMETERS
Level 1" for validation
âŚ
Press
"INSTALL
NEXT"
in
the âŚ
"ETHERNET
INSTALLATION
PARAMETERS" window.
45321648.01
NumĂŠro / Number
108
Doc.
The value remains unchanged
The "INSTALLATION PARAMETERS Level 1"
window appears on the PCL.
9932 V2
Checked
Rev.
Langu.
27/06/2006
21 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
Leaving the installation mode: When the PCL displays the "INSTALLATION PARAMETERS Level 1"
window, proceed as follows :
ACTIONS
Leaving the
installation mode
âŚ
âŚ
Press
the
valid
key
in
the âŚ
"INSTALLATION PARAMETERS Level 1"
window
âŚ
Set switch SW1, situated in the
exciter/CPU interconnection card, such
âŚ
that the dot is not visible.
The transmitter stores the new configuration
parameters.
The system is initialised with the new status and
operational parameters.
The "STATUS" window appears and indicates
that the system is in normal operating mode.
Reset the CPU board
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
âŚ
RESULT
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
22 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.6. Procedures for adjusting or changing operational parameters
1.6.1.
Procedure to call the maintenance mode
Adjustments or changes to operational parameters can only be carried out in maintenance mode and
when the PCL is unlocked.
If the PCL screen is locked (disabled), unlock it (refer to procedure for unlocking the PCL, § procedure
lock or unlock the PCL.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
ACTIONS
To call up the
"CONTROL" window
of the PCL:
âŚ
If the transmitter is in âŚ
normal mode, switch
to maintenance mode
âŚ
To call up the
"CONTROL MAINT
Level 2" window
1.6.2.
âŚ
RESULT
âŚ
The PCL "CONTROL Level 1" window
appears.
Press on the ÂŤMODEÂť key in the PCL âŚ
"CONTROL Level 1" window.
The "NORMAL" message window above the
ÂŤMODEÂť key is replaced by a flashing "MAINT
MODE" message window.
Press the "CONTROL" key.
Press the "VALID" key.
âŚ
The "MAINT" message window stops flashing and
remains lit.
âŚ
The system is now in maintenance mode.
Press "CONTROL LEVEL 2" in the âŚ
"CONTROL Level 1" window.
The "CONTROL MAINT Level 2" window
appears.
Procedure for adjusting the calibrated transmitter power
Adjustments or changes to calibrated transmitter power can only be carried out in installation mode.
The calibrated transmitter can be inserted in the â INSTALLATION PARAMETERS Level 1â window of
the PCL. The RF probes of the transmitter are adjusted depending on required power value and
according to RF feedback input value.
ACTIONS
To call up the
"INSTALLATION
PARAMETERS
Level 1" window
âŚ
CONSEQUENCES
Set switch SW1, situated in the âŚ
exciter/CPU interconnection card on the
side of the sub-units behind the CPU âŚ
card, such that the dot is visible,
The transmitter is switched to installation mode.
The "INSTALLATION PARAMETERS Level 1"
window appears on the PCL and displays the
current transmitter configuration parameters.
âŚ
Reset CPU board.
Select the required
power value
âŚ
In the "INSTALLATION PARAMETERS
LEVEL 1" window, press on the "CAL
PWR" key.
To insert a parameter
value
âŚ
Enter the calibrated value on the window âŚ
keyboard,
The "NUMERICAL VALUE" window appears.
âŚ
Press "ENTER" to validate the entry.
âŚ
The value is displayed under the window title.
âŚ
The "INSTALLATION PARAMETERS" window
appears.
âŚ
The "INSTALLATION PARAMETERS Level 1"
window reappears.
âŚ
The calibrated power value remains unchanged
Note:
To cancel an entry press on the "EXIT" key.
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
23 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
ACTIONS
Leaving the
installation mode
âŚ
Press
the
valid
key
in
the âŚ
"INSTALLATION PARAMETERS Level 1"
window,
The transmitter stores the new configuration
parameters.
âŚ
Set switch SW1, situated in the âŚ
exciter/CPU interconnection card, such
that the dot is not visible,
âŚ
Reset the CPU board.
The system is initialised with the new status and
operational parameters.
âŚ
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
1.6.3.
CONSEQUENCES
The "STATUS" window appears and indicates
that the system is in normal operating mode.
Procedure for adjusting the required transmitter power
Having already configured the system in maintenance mode and also having unlocked the PCL and
called up the "TRANSMITTER STATUS" window, carry out the following operations :
ACTIONS
Select the required
power value
âŚ
1 - To insert the
required power value
RESULT
In
the
"TRANSMITTER
STATUS" âŚ
window, press on the "REQUIR POWER"
âŚ
key
The "REQUIRED POWER" window appears.
âŚ
Enter the required value on the window âŚ
keyboard,
The new current value is displayed under the
window title
âŚ
Press "ENTER" to validate the entry.
âŚ
The system activates the new power reduction
value.
Press âCANCELâ key in the "REQUIRED âŚ
POWER" window.
The "TRANSMITTER STATUS" or "RF LEVELâ
window appears.
âŚ
The system ignores the new power reduction
value.
In the "POWER REQUIRED" window, âŚ
press on the
"x dB" key successively
until the required power reduction value is
displayed
âŚ
Press the "ENTER" key for Validation of
âŚ
selection:
The available values of power reduction appear
successively on the key. he key flashes until the
selection is validated.
IMPORTANT :
The current value is displayed under the window
title.
Range of variation:
0.25 *Cal Pwr < REQ Pwr < 1.12 Cal
Pwr and
REQ Pwr < MAX Pwr
Cancelling the selection:
âŚ
2 - Select the
required power
reduction value:
âŚ
âŚ
Cancelling the selection:
âŚ
The "x DB" key stops flashing and remains lit.
The system activates the new power reduction
value.
Press âCANCELâ key in the "REQUIRED âŚ
POWER" window.
The "TRANSMITTER STATUS" or "RF LEVELâ
window appears.
âŚ
The system ignores the new power reduction
value.
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
24 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.6.4.
Procedure for changing the modulator input
This procedure describes how to change the input signal type of the modulator unit and the clock type
of ADAPT exciter in DVB-T Transmitter only.
Having already configured the system in local control, maintenance mode, and also having unlocked
the PCL and called up the âCOFDM PARAMETERSâ window.
Note :
⌠MODAP Version only
To set up a new parameter configuration of the modulator, the three corrections (ALE,
LUT and OLDC) should be set to the FIXED mode. The control keys can be defined in
the "MISCELLANEOUS" window and "CONTROL MAINT Level 4" window.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
⌠SIRIUS Version only
To set up a new parameter configuration of the modulator, the two corrections (ALE, and
LUT) should be set to the FIXED mode. The control keys can be defined in the
"MISCELLANEOUS" window.
ACTIONS
Set the corrections of
ADAPT exciter to
FIXE MODE :
Select the required
parameters input
RESULT
In FIXE position, the correction parameters are not
continuously adjusted.
âŚ
Refer to procedure for changing the
configuration parameters of the ADAPT
exciter.
âŚ
Refer to procedure for changing the âŚ
configuration parameters of the OLDC
card (Available in MODAP version only).
OLDC correction is in FIXE MODE.
âŚ
In the âCOFDM PARAMETERSâ window, âŚ
press on the âDATA XXXXâ key
successively until the required input
signal type is displayed.
The available values of input parameters appear
successively on the key.
âŚ
In the âCOFDM PARAMETERSâ window, âŚ
press on the âCLOCK XXâ key
successively until the required clock type
is displayed.
The key flashes until the selection is validated.
Press the âVALIDâ key.
âŚ
The âDATAâ or âLOCKâ keys stops flashing
and remains lit.
âŚ
The system
parameter
âŚ
The system ignores the new input parameter.
Validation of selection âŚ
ALE and LUT corrections are FIXE MODE.
activates
the
new
input
Cancelling the
selection
âŚ
Press the âCANCELâ key.
Set the corrections of
ADAPT exciter to
ADAPTIVE MODE
âŚ
Refer to changing the configuration âŚ
parameters of the ADAPT exciter.
ALE and LUT corrections are ADAPT
MODE.
âŚ
Refer to for changing the configuration âŚ
parameters of the OLDC card (Available
in MODAP version only)..
OLDC correction is in ADAPT MODE.
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
25 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.6.5.
Procedure for changing the configuration of the Adaptation parameters (ALE
and LUT)
This procedure provides for changing the type of linearity "ALE" and non linearity "LUT" signal
correction (fixed or adaptive) performed by the DAP card (MODAP version) or TS card (SIRIUS
version).
Summary
In fixed position, the correction parameters are not continuously adjusted.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Having already configured the system in local control, maintenance modes, and also having unlocked
the PCL and called up the "MISCELLANEOUS" window (refer to procedures which are necessary prior
to adjusting or changing an operational parameter), carry out the following operations :
ACTIONS
RESULT
To change the type ⌠Press "N. LIN COR ADAPTIVE MODE" ⌠The control keys flashes and displays the new
(or
"FIXED
MODE")
in
the
selection in reverse video.
of correction
âMISCELLANEOUSâ window.
Validation of
selection
1.6.6.
Note :
âŚ
Press " LIN COR ADAPTIVE MODE" (or âŚ
"FIXED
MODE")
in
the
"MISCELLANEOUS" window.
âŚ
Press the "VALID" key.
âŚ
The control keys flashes and displays the new
selection in reverse video.
The control keys label stops flashing and displays
the new selection picked up the system in normal
video.
Procedure for changing the configuration parameters of the OLDC card
This procedure is achieve in COFDM MODAP version only
This procedure provides for changing the type of signal correction (fixed or adaptive) performed by the
OLDC card.
Remember
In fixed position, the correction parameters are not continuously adjusted.
Having already configured the system in local control, maintenance modes, and also having unlocked
the PCL and called up the "CONTROL MAINTENANCE Level 4" window (refer to procedures which
are necessary prior to adjusting or changing an operational parameter), carry out the following
operations :
ACTIONS
RESULT
To change the type of âŚ
correction
Press
"SELECT
MODE"
in
"CONTROL MAINT Level 4" window
Validation of selection âŚ
Press the "VALID" key.
âŚ
The message window above the "SELECT
MODE" control keys stops flashing and
remains lit while displaying the newly
selected operating mode.
Press the "CANCEL" key.
âŚ
The message window above the "SELECT
MODE" control keys stops flashing and
remains lit while displaying the operating
mode which had been previously selected.
Cancelling the
selection
âŚ
45321648.01
NumĂŠro / Number
the âŚ
108
Doc.
The message window above the control
keys flashes while displaying the newly
selected operating mode (OLDC ADAPT or
OLDC FIXE).
9932 V2
Checked
Rev.
Langu.
27/06/2006
26 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.6.7.
Procedure for changing the frequency of the RF synthesiser
Having already configured the system in maintenance mode and also having unlocked the PCL and
called up the "CONTROL MAINT Level 3" window (refer to procedures which are necessary prior to
adjusting or changing an operational parameter), carry out the following operations :
ACTIONS
To change the
frequency
CONSEQUENCES
The "NUMERICAL VALUE" appears.
âŚ
In the "CONTROL MAINT Level 3"
window, press on the "FREQ SYNTHE
(Hz)" key.
âŚ
Enter the frequency value on the window âŚ
keyboard.
The value is displayed under the window title.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
IMPORTANT :
Before validating a new synthesiser
frequency, make sure that the settings of all
RF filters (ex. output RF filter, RF combiner,
...) are consistent with the new frequency.
Validation of selection âŚ
Press "ENTER" to validate the entry.
The "CONTROL MAINT Level 3" window reappears.
The new frequency value is displayed in the "FREQ
SYNTHE (Hz)" key.
Cancelling the
selection
1.6.8.
âŚ
Press the "CANCEL" key.
âŚ
The "CONTROL MAINT" window reappears.
âŚ
The frequency value remains unchanged.
Procedure for changing ripple and shoulder threshold settings in maintenance
mode
This procedure describes how to change the ripple and shoulder thresholds beyond which the ADAPT
exciter performs a correction.
Having already configured the system in local control, maintenance modes, and also having unlocked
the PCL and called up the "CONTROL MAINTENANCE Level 3" window (refer to procedures which
are necessary prior to adjusting or changing an operational parameter), carry out the following
operations :
ACTIONS
Changing thresholds
RESULT
âŚ
Press on the message window of the
threshold to be changed.
âŚ
Enter the required value on the window
keyboard.
Validation of selection âŚ
Press "ENTER" to validate the entry.
The "NUMERICAL VALUE" window appears.
The value is displayed under the window title.
The "CONTROL MAINT Level 3" window reappears.
The new threshold value is displayed on the
corresponding key.
Cancelling the
selection
âŚ
The "CONTROL MAINT Level 3" window reappears.
Press the "CANCEL" key.
âŚ
45321648.01
NumĂŠro / Number
108
Doc.
The threshold value remains unchanged.
9932 V2
Checked
Rev.
Langu.
27/06/2006
27 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.6.9.
Note :
Procedure for changing the threshold settings of the OLDC card
This procedure is achieve in COFDM MODAP version only
This procedure describes how to change the central frequency rejection threshold and the I/Q
amplitude error threshold beyond which the OLDC card performs a correction.
Having already configured the system in local control, maintenance modes, and also having unlocked
the PCL and called up the "CONTROL MAINTENANCE Level 4" window (refer to procedures which
are necessary prior to adjusting or changing an operational parameter), carry out the following
operations :
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
ACTIONS
Changing thresholds
RESULT
âŚ
Press on the message window of the
threshold to be changed.
The
âŚ
Enter the required value on the window
keyboard.
The value is displayed under the window title.
Press "ENTER" to validate the entry.
The "CONTROL MAINT Level 4" window reappears.
Validation of selection âŚ
"NUMERICAL
VALUE"
window
appears.
The new threshold value is displayed on the
corresponding key.
Cancelling the
selection
âŚ
The "CONTROL MAINT Level 4" window reappears.
Press the "CANCEL" key.
âŚ
The threshold value remains unchanged.
1.6.10. Procedure for changing RF digital power threshold settings for triggering
alarm and fault signals
This procedure describes how to change digital power threshold settings for triggering alarm and fault
signals on the PCL (three-colour "Alarm" indicator lamp).
Having already configured the system in maintenance mode and also having unlocked the PCL and
called up the "CONTROL MAINT Level 2" window (refer to procedures which are necessary prior to
adjusting or changing an operational parameter), carry out the following operations :
ACTIONS
RESULT
To call up the ÂŤRF
THRESHOLDÂť
window of the PCL
âŚ
In the "CONTROL MAINT Level 2" âŚ
window, press on the "RFTHRES" key.
The ÂŤRF THRESHOLDÂť window appears.
Changing thresholds
âŚ
Press on the message window of the âŚ
threshold to be changed.
The "NUMERICAL VALUE" window appears.
âŚ
Enter the required value on the window âŚ
keyboard.
The value is displayed under the window
title.
Press "ENTER" to validate the entry.
âŚ
The ÂŤRF THRESHOLDÂť window reappears.
âŚ
The new threshold value is displayed on the
corresponding key.
âŚ
The ÂŤRF THRESHOLDÂť window reappears.
âŚ
The threshold value remains unchanged.
Validation of sĂŠlection âŚ
Cancelling the
selection
âŚ
Press the "CANCEL" key.
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
28 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.6.11. Procedures for changing quality thresholds
The quality threshold is the maximum permissible deviation (in dB) from a set point before the
occurrence of a major fault (overall quality assessment of 13/20), which produces a transmitter
changeover in an N+1 or Passive Reserve system. In SD or DD systems, no changeover is
performed.
⌠The set point (Shoulder, Ripple) is the parameter threshold beyond which the ADAPT exciter
performs a correction. The set points can be defined in the "CONTROL MAINT Level 3" window.
⌠The power set point is the calibrated RF power of the transmitter, it is fixed and is available to the
operator in the "INSTALLATION PARAMETERS Level 1" window.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Having already configured the system in maintenance mode and also having unlocked the PCL and
called up the "CONTROL MAINT Level 2" window (refer to procedures which are necessary prior to
adjusting or changing an operational parameter), carry out the following operations :
ACTIONS
RESULT
To call up the
"QUALITY
THRESHOLD
SETTINGS" window
âŚ
In the "CONTROL MAINT Level 2" âŚ
window, press on the "QUALITY
THRESHOLDS" key.
Changing quality
thresholds
âŚ
Press on the message window of the
threshold to be changed.
âŚ
Enter the required value on the window âŚ
keyboard.
Validation of selection âŚ
Cancelling the
selection
âŚ
Press "ENTER" to validate the entry.
The "QUALITY THRESHOLD SETTINGS"
window appears on the PCL and displays the
current quality thresholds.
The
"NUMERICAL
VALUE"
window
appears.
The value is displayed under the window title.
âŚ
The "QUALITY THRESHOLD
window reappears.
âŚ
The new threshold value is displayed on the
corresponding key.
SETTINGS"
The "QUALITY THRESHOLD SETTINGS" window
reappears.
Press the "CANCEL" key.
âŚ
The threshold value remains unchanged.
1.6.12. Procedure for setting the time and the date
Having already configured the system in maintenance mode and also having unlocked the PCL and
called up the "CONTROL MAINT Level 2" window (refer to procedures which are necessary prior to
adjusting or changing an operational parameter), carry out the following operations:
ACTIONS
RESULT
To call up the "DATE
& TIME" window of
the PCL
âŚ
Press on the "DATE" key in the âŚ
"CONTROL MAINT Level 2" window.
The "DATE & TIME" window appears; the time
and date values are frozen to the time instant
when the window was called up.
Changing the time
and date values
âŚ
Set the time and date values using the âŚ
incrementation and decrementation keys
("+" and "-").
The changed parameter values appear in the
corresponding message windows. The number
resulting from the increment or decrement is
being displayed between the two control keys ("+"
and "-") .
Press "VALID" to validate the entry.
âŚ
The new values appear under the title of window
"DATE & TIME".
press on the "EXIT" key.
âŚ
The "CONTROL
reappears.
âŚ
The time and date settings have not been
changed. If the "VALID" key of the "DATE &
TIME" window was not selected.
Validation of selection âŚ
Cancelling the
selaction
âŚ
45321648.01
NumĂŠro / Number
108
Doc.
MAINT
9932 V2
Checked
Rev.
Langu.
27/06/2006
Level 2"
window
29 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.7. Procedure for changing the PCL password
For this procedure the system can be either in maintenance mode or normal mode. With the PCL
enabled and the "CONTROL MAINT Level 2" window or "CONTROL OPER Level 2" window already
called up, carry out the following operations :
ACTIONS
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Insertion of current
password
CONSEQUENCES
âŚ
Press on the "MODIFY PASSWORD" âŚ
message window in the "CONTROL
MAINT Level 2" window or in the
"CONTROL OPER Level 2" window.
The "NUMERICAL VALUE" window appears
showing the "ENTER NEW PASSWORD" prompt.
âŚ
Enter the current password on the âŚ
window keyboard.
Asterisks are displayed in order to hide the
password.
âŚ
Press "ENTER" to validate the entry.
âŚ
If the password is correct: the "ENTER NEW
PASSWORD" prompt is displayed.
âŚ
If the password is incorrect: the message
"INVALID PASSWORD" is displayed in the
window; try again.
âŚ
The "CONTROL MAINT Level 2" or "CONTROL
OPER Level 2" window appears.
Note:
Insertion of new
password
âŚ
To cancel an entry press the "CANCEL"
key.
âŚ
âŚ
Enter the new password on the window âŚ
keyboard.
Asterisks are displayed in order to hide the
password
âŚ
Press "ENTER" to validate the entry. âŚ
The user is prompted to confirm the new
password: "CONFIRM NEW PASSWORD" is
displayed in the window.
âŚ
Enter the new password again on the âŚ
window keyboard.
Asterisks are displayed in order to hide the
password.
âŚ
Press "ENTER" to validate the entry.
âŚ
âŚ
The password has not been changed.
If the second password entry is correct:
â˘
The "CONTROL MAINT Level 2" window or
the "CONTROL OPER Level 2" window
reappears.
â˘
The password has been changed.
If the password is incorrect: the message
"INVALID PASSWORD" is displayed in the
window :
â˘
The "CONTROL MAINT Level 2" window or
the "CONTROL OPER Level 2" window
reappears.
â˘
The password has not been changed.
â˘
Try again.
Note:
âŚ
To cancel an entry press the "CANCEL" âŚ
key.
âŚ
45321648.01
NumĂŠro / Number
108
Doc.
The "CONTROL MAINT Level 2" or "CONTROL
OPER Level 2" window appears.
The password has not been changed.
9932 V2
Checked
Rev.
Langu.
27/06/2006
30 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.8. Procedures for changing a status condition or transmitter operating mode
1.8.1.
1.8.1.1.
Procedure for lock to unlock the PCL
Procedure for lock the PCL
ACTION
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
With the PCL
unlocked
1.8.1.2.
âŚ
RESULT
Press on "LOCK PCL" key in the âŚ
"STATUS" window.
âŚ
The PCL "Unlock" indicator lamp lights up.
Message "LOCK PCL" displayed in the "STATUS"
window.
âŚ
In the "STATUS" window: the message "LOCK
PCL" displayed in normal video is replaced by the
message "PCL LOCKED" displayed in reverse
video.
âŚ
The PCL "Unlock" indicator lamp is extinguished.
Procedure for unlock the PCL
ACTION
RESULT
With the PCL locked
âŚ
Enter the user password:
âŚ
Press on "PASSWORD" control keys in
the "STATUS" window.
âŚ
Enter the password on the window
keyboard.
Note:
âŚ
âŚ
The PCL "Unlock" indicator lamp is extinguished.
âŚ
"PCL LOCKED" message is displayed in the
"STATUS" window in reverse video.
âŚ
The "NUMERICAL VALUE" window appears
Asterisks are displayed under the window title in
order to hide the password.
âŚ
The "STATUS" window appears: the message
"PCL LOCKED" in reverse video is replaced by
the message "LOCK PCL" displayed in normal
video.
âŚ
The PCL "Unlock" indicator lamp lights up. If not
the inserted password is not valid.
âŚ
The "STATUS" window appears.
To cancel an entry press the "CANCEL" âŚ
key.
45321648.01
NumĂŠro / Number
108
Doc.
The PCL screen is still locked.
9932 V2
Checked
Rev.
Langu.
27/06/2006
31 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.8.2.
Selection of transmitter operation mode
Selecting the transmitter operating mode (maintenance mode or normal mode) is carried out in the
PCL "CONTROL Level 1" window.
This operation is only possible if the PCL is unlocked (see § Procedure to Unlock the PCL).
Note:
In normal mode all transmitter functions are operational. No settings or parameters can be
adjusted by the operator.
In maintenance mode :
⌠The fault processing facilities are not operational,
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
⌠The operator can adjust some settings and parameters.
ACTIONS
RESULT
Selection of operating âŚ
mode
(NORMAL/MAINT)
Press the ÂŤMODEÂť control keys in the âŚ
"CONTROL Level 1" window.
The message window above the control
keys flashes indicating the newly selected
operating mode which can be either the
maintenance mode or normal mode.
Validation of selection âŚ
Press the "VALID" key.
âŚ
The message window above the "MODE"
control keys stops flashing and remains lit
while displaying the newly selected
operating mode.
Press the "CANCEL" key.
âŚ
The message window above the "MODE"
control keys stops flashing and remains lit
while displaying the operating mode which
had been previously selected.
Cancelling the
selection
1.8.3.
âŚ
Manuel change over of exciter
Only in Double Drive Version
The procedure for manual changeover of exciter is only possible if the PCL is unlocked, and if the
system is in local control mode. It consists of changing the exciter already selected.
It can be carried out in the "EXCITER Level 1" window.
ACTION
Changing the
selected exciter
âŚ
Validation of selection âŚ
Cancelling the
selection
âŚ
RESULT
Press on "EXCITER" control keys in the âŚ
"EXCITER Level 1" window.
The ÂŤEXC A (or B)Âť message window flashes
while displaying the reserve exciter.
Press the "VALID" key.
âŚ
The ÂŤEXC A (or B)Âť message window stops
flashing and remains lit while displaying the newly
selected exciter.
Press the "CANCEL" key.
âŚ
The ÂŤEXC A (or B)Âť message window stops
flashing and remains lit while displaying the
previously selected exciter.
Exciter changeover override
Switches SW4 and SW5 on the exciter/CPU interconnection card provide for switching exciter A
(SW4) or B (SW5) to air if the CPU card is unavailable or missing.
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
32 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.8.4.
Selection of exciter changeover mode
Only in Double Drive Version
The selection of the exciter changeover mode is only possible if the PCL is unlocked, i.e. enabled (see
relevant procedure).
It is carried out using the "EXCITER Level 1" window independently of the transmitter operating mode
(normal mode or maintenance mode).
Note:
The changeover switch between the two exciters can take place automatically or under
manual control.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
⌠In the automatic changeover mode the facilities for an automatic switch between the two
exciters (A â B or B â A) if a fault appears on the selected exciter channel have been
enabled; in this mode it is possible to initiate the changeover switch manually.
In the automatic changeover mode the identity of the selected exciter is not changed; this
is not the case with manual changeover.
⌠In the manual changeover mode the switch can only take place as a result of a command
from a user interface (PCL or remote user interface)
The manual changeover switch changes the identity of the selected exciter.
ACTIONS
Selection of
changeover mode
âŚ
Validation of selection âŚ
Cancelling the
selection
1.8.5.
âŚ
RESULT
Press on "CH OVER" control keys in the âŚ
"EXCITER Level 1" window.
The ÂŤMAN (or AUTO)Âť message window
flashes while displaying the newly selected
changeover mode (manual or automatic).
Press the "VALID" key.
âŚ
The ÂŤMAN (or AUTO)Âť message window
stops flashing and remains lit while
displaying the newly selected changeover
mode.
Press the "CANCEL" key.
âŚ
The ÂŤMAN (or AUTO)Âť message window
stops flashing and remains lit while
displaying the changeover mode previously
selected.
Selection of user interface
The selection of a local (PCL) or remote user interface can only be carried out at the PCL.
For this selection it is not necessary to enable the PCL.
It is carried out using the "CONTROL Level 1" window independently of the transmitter operating
mode (normal mode or maintenance mode).
ACTION
Selection of user
interface
âŚ
Validation of selection âŚ
Cancelling the
selection
âŚ
RESULT
Press on "CTRL" control keys in the âŚ
"CONTROL
The message window above the "CTRL" control
keys flashes and displays the newly selected user
interface (remote or local).
Press the "VALID" key.
âŚ
The message window above the "CTRL" control
keys stops flashing and remains lit while
displaying the newly selected user interface.
Press the "CANCEL" key.
âŚ
The message window above the "CTRL" control
keys stops flashing and remains lit while
displaying the previously selected user interface.
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
33 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.9. Procedure for switching on and off
1.9.1.
Switching on-air and switching off-air
Switching on (TX on) means switching the transmitter to air when mains has already been switched to
the transmitter.
Switching off (TX off) means taking the transmitter off-air while keeping the mains switched on.
On-air and off-air switching are carried out by using the "ON" and "OFF" keys of the PCL.
ACTION
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Switching the
transmitter on
Switching the
transmitter off
âŚ
âŚ
RESULT
Press on the PCL "ON" key.
Press on the PCL "OFF" key.
âŚ
The PCL "On" indicator lamp lights up to indicate
that the transmitter is on-air.
âŚ
The amplifier power supplies and cooling system
are switched on.
âŚ
The system is on-air.
âŚ
The PCL "Off" indicator lamp lights up to indicate
that the transmitter is off-air.
âŚ
The amplifier power supplies and cooling system
are switched off.
âŚ
The system is off-air.
On/off override
The SW2 and SW3 switches on the exciter/CPU interconnection card and RSCOM software can be
used to switch the transmitter off (SW3) or on (SW2) if the CPU card is missing or faulty.
1.9.2.
Switching the reserve exciter on and off
Only in Double Drive Version
Switching the reserve exciter on and off is only possible if the PCL is unlocked, i.e. enabled (see
relevant procedure).
It is carried out using the "CONTROL Level 1" window independently of the transmitter operating
mode (normal mode or maintenance mode).
Note :
While the reserve exciter is on, automatic changeover of the exciters is impossible.
ACTION
Selection
âŚ
Validation of selection âŚ
Cancelling the
selection
âŚ
RESULT
Press the "STDBY" control keys in the âŚ
"CONTROL Level 1" window.
The message window above the control
keys flashes while displaying the function
(on or off) to be carried out.
Press the "VALID" key.
âŚ
The message window above the "STDBY"
control keys stops flashing and remains lit
while displaying the status (on or off) of the
reserve exciter.
Press the "CANCEL" key.
âŚ
The message window above the "STDBY"
control keys stops flashing and remains lit
while displaying the status (on or off) of the
reserve exciter.
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
34 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.10. Procedure for adjusting PCL screen contrast
ACTION
RESULT
Adjusting the contrast âŚ
Press on the upper left and right corners âŚ
of the screen.
A range of contrast values appears in the bottom
of the screen.
âŚ
Press on the tab which corresponds to âŚ
the required contrast.
The screen contrast changes.
âŚ
Press in the centre of the screen.
The range of contrast values disappears.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
âŚ
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
35 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.11. Procedure for transmitter reset
ACTIONS
âŚ
Press on the PCL "RESET" key.
âŚ
Faults will be erased and their consequences will
be cancelled.
âŚ
Any power reduction carried out will be cancelled.
âŚ
Operator selections carried out on the PCL will be
cancelled.
âŚ
Return to selected exciter if an automatic
changeover has been carried out.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Transmitter reinitialisation
CONSEQUENCES
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
36 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.12. Procedure for using maintenance information
1.12.1. Display of faults and status conditions
1.12.1.1. Display of last three faults to appear
ACTION
âŚ
RESULT
âŚ
Call up "STATUS" window of the PCL.
Last three faults to appear are displayed.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Note:
Other faults can be examined using the log book.
1.12.1.2. Displaying power amplifier status conditions
ACTION
Selecting an amplifier
Display the status
conditions of the
other amplifiers by
changing
RESULT
âŚ
Call up "AMPLIFIERS" window of the
PCL.
âŚ
Select the bay which contains
amplifier using the "Âą CAB" keys *.
the âŚ
The number of the selected bay is displayed on
the key.
âŚ
Select the amplifier using the "Âą AMPLI" âŚ
keys.
The number of the selected amplifier is displayed
on the key.
âŚ
Message windows show the status conditions of
the amplifier selected. A faulty status is displayed
in reverse video (on white background).
âŚ
The amplifier using the "Âą AMPLI" keys.
âŚ
If necessary the bay using the "Âą CAB" âŚ
keys *.
Message windows show the
conditions of the new amplifier.
status
* Only high-power transmitters with more than one cabinet.
1.12.1.3. Displaying amplifier power supply status conditions
ACTION
âŚ
RESULT
Call up the ÂŤPOWER SUPPLYÂť window âŚ
of the PCL.
The window displays the status conditions of the
amplifier power supplies in the cabinet shown in
the "Âą CAB" message window. A faulty status is
displayed in reverse video (on white background).
If necessary the status conditions of the âŚ
power supplies in another cabinet can be
displayed by selecting the other bay using
the "Âą CAB" keys *.
A cabinet which has not been configured cannot
be accessed using the Âą keys.
* Only high-power transmitters with more than one cabinet.
45321648.01
NumĂŠro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
37 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.12.1.4. Displaying protection system status conditions
ACTION
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
âŚ
RESULT
Call up the "INTLOCK" window of the âŚ
PCL.
This window has the facilities to display the status
conditions of the protection system in the cabinet
whose number appears on the "Âą CAB" display.
The data from the sensors are arranged in the
order in which they physically appear in the actual
cabinet. The data to the left of the vertical bar in
the window trigger an emergency shutdown when
the associated fault occurs; those to the right of
the bar leave the transmitter in operation. A faulty
status is displayed in reverse video (on white
background).
If necessary, the status conditions for the âŚ
protection system in another bay can be
displayed by selecting the other cabinet
using the "Âą CAB" keys *.
A cabinet which has not been configured cannot
be accessed using the Âą keys.
* Only high-power transmitters with more than one cabinet.
1.12.1.5. Displaying exciter card status conditions
Single Drive Version
ACTION
âŚ
RESULT
Call up the "EXCITER PANEL" window of âŚ
the PCL.
This window displays the exciter status
conditions. The message window for a fault is
displayed in reverse video (on a white
background).
Only in Double Drive Version
ACTION
RESULT
This window provides the status conditions of the
exciter cards. The message window for a faulty card
is displayed in reverse video (on white background).
âŚ
Call up the "EXCITER Level 1" window of
the PCL.
âŚ
Press "EXCITER (2)" in the "EXCITER âŚ
Level 1" window.
âŚ
The "EXCITER Level 2" window appears.
This window shows the status conditions for
signals processed by the exciters. A faulty status
is displayed in reverse video (on white
background).
1.12.1.6. Check on signal quality
ACTION
RESULT
âŚ
To call up the "RF LEVEL" window
âŚ
Press "RF LEVEL" in the "CONTROL âŚ
MAINT Level 2" window.
45321648.01
NumĂŠro / Number
108
Doc.
âŚ
The "RF LEVEL" window is displayed.
This window displays the quality variables of the
RF feedback signal (ripple level, shoulder level,
gain and quality assessment), the power and the
SWR of the output RF signal of the transmitter.
9932 V2
Checked
Rev.
Langu.
27/06/2006
38 / 192
Page
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 38 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:5c4869e8-db35-4db5-b11e-83b3aea02bf9 Modify Date : 2006:07:07 13:19:41-04:00 Create Date : 2006:07:07 13:19:05-04:00 Metadata Date : 2006:07:07 13:19:41-04:00 Document ID : uuid:98e37da0-8b87-465e-adf5-1fbea9297a4c Format : application/pdf Tagged PDF : Yes Title : PREIMPAP.DOC Creator : Acrobat PDFMaker 6.0 pour Word Author : TBM Subject : Instructions de formatage du modle PREIMPAP.DOT Producer : Acrobat Distiller 6.0 (Windows)EXIF Metadata provided by EXIF.tools