Thomson Broadcast and Multimedia ULT-1K10K2 UHF Digital transmitter, for use with MediaFlo User Manual PREIMPAP
Thomson Broadcast & Multimedia, Inc. UHF Digital transmitter, for use with MediaFlo PREIMPAP
Contents
User Manual part 4
Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators MESSAGE FUNCTIONS DISPLAY/COMMENTS Shows the double column of the relevant exciter. (*) Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Indicates which exciter is selected and which is on-air, as well as the status (fault-free or faulty) of both exciters (1). EXCITER A / EXCITER B Message is displayed on green background: Exciter selected Message is displayed on yellow background: Exciter non selected Indicates the overall status of the COFDM modulator. MODULAT OK / MODULAT FAULT (1) Indicates the overall status of the TS card. TS OK / TS FAULT / TS MISSING (1) Indicates the overall status of the TX card. TX OK / TX FAULT / TX MISSING (1) Indicates the preamplifier. PREAMP OK / PREAMP FAULT (1) overall status of the Indicates the overall status of the RF synthesiser. SYNTHE OK / SYNTHE FAULT (1) Indicates the status of the 10 MHz drive oscillator. 10 MHz EXT / 10 MHz INT First case: "10 MHz INT" control keys in "INSTALLATION PARAMETERS Level 1" window is selected. ♦ A status message (10 MHz ext or 10 MHz INT) is displayed in normal video (on black background). Second case: "10 MHz EXT" control keys in "INSTALLATION PARAMETERS Level 1" window is selected. Indicates the overall status of the GPS receiver card. ♦ A status message (10 MHz EXT) is displayed in normal video (on black background). ♦ A fault message (10 MHz INT) is displayed in reverse video (on white background). GPS OK / GPS FAULT/ GPS MISSING / NOT VISIBLE (1) The “GPS” key in “EXCITER” window is not available (not visible) when the optional card is not present. Indicates the presence or absent of the 1PPS. 1PPS ABSENT / 1PPS PRESENT ♦ Operation mode used: “INTERNAL GPS” The signal status is delivered from internal GPS card. ♦ Operation mode used: “EXTERNAL GPS” The signal status is coming from 1PPS input signal. Indicates the overall status of the SWITCH ALE card. SWITCH OK / SWITCH FAULT (1) Indicates the status of the AGC loop AGC OK / AGC FAULT (1) FAULT: The AGC voltage is out of the operation range: +- 2dB (0,5 to 2,5V) regarding AGC reference. It’s displays in “AGC SETTING” screen. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 117 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators MESSAGE FUNCTIONS DISPLAY/COMMENTS Indicates the level of the feedback signal for Linear Correction (Ripple) FdB LC OK / FdB LC FAULT (1) FAULT: The RF feedback level is out of the operation range: FLO or COFDM modulator used: typical –10dBm to 0dBm 8VSB modulator used: typical –15dBm to +2dBm Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Indicates the level of the feedback signal for No Linear Correction (Shoulder) FdB NLC OK / FdB NLC FAULT (1) FAULT: The RF feedback level is out of the operation range: FLO or COFDM modulator used: typical –10dBm to 0dBm 8VSB modulator used: typical –15dBm to +2dBm (1) A fault free status is displayed in normal video (on black background or on green background in case of colour tactile screen). A faulty status is displayed in reverse video (on white background or on red background in case of colour tactile screen). 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 118 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.30. "FLO 1 MODULATOR" window This window is called up by pressing the "MODUL" control keys in the "EXCITER PANEL" window (SD transmitters) or in the "EXCITER Level 2" window (DD transmitters). Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. It displays the MediaFLO modulator card parameters used in the exciter. MESSAGES FUNCTIONS SELECTIONS AVAILABLE/COMMENTS Gives the name windows Displays the transmitter ID number actual in an SFN network. This value allows addressing the content of the MIP to this identified Tx. Displays the actual input signal type of the modulator ASI / PRBS Displays the actual clock type of the exciter. CLOCK Internal / GPS Internal / GPS External Displays the actual process PID number. 45321648.01 Numéro / Number 108 Doc. ♦ WA PID : This value is programmed Wid Area content process identification (PID). If the wide area PID value in the incoming transport stream matches this value, the stream is forwarded to the channelizer as wide area content. Otherwise, the stream is ignored. ♦ LA PID : This value is programmed Local Area content process identification (PID). If the local area PID value in the incoming transport stream matches this value, the stream is forwarded to the channelizer as local area content. Otherwise, the stream is ignored. 9932 V2 Checked Rev. Langu. 27/06/2006 119 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators MESSAGES FUNCTIONS SELECTIONS AVAILABLE/COMMENTS Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Displays the actual delay value. ♦ Mod Dly : The number of clock cycles corresponding to the delay through the FLO modulator core. This is set to align the start of superframe at the RF output to the GPS 1PPS. ♦ TX Dly : This value is the latency associated with the transmit hardware. It’s used to compensate for the transmit delay in order to synchronize transmissions from multiple sites in an SFN network. ♦ Ntw Dly: This value is the latency associated with the geographic separation of transmitters. It’s used to synchronize transmissions from multiple sites in an SFN network. ♦ SFN lim: If the absolute value of the system clock integrity count is greater than this limit, it is out of range and an alarm generated. Pressing this key calls up the "NUMERICAL VALUE" window in which this value can be changed. Indicates which exciter data are displayed EXC A / EXC B (*) (*): Only Dual Drive version CONTROL KEYS FUNCTIONS SELECTIONS AVAILABLE/COMMENTS Calls up data from the other exciter (*). Calls up the "FLO 2 MODULATOR" window. Calls up the "STATUS" window. Calls up the "CONTROL LEVEL 1" window. Calls up the "EXCITER Level 1" window. Calls up the "AMPLIFIERS" window. Calls up the «INTERLOCK» window 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 120 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators CONTROL KEYS FUNCTIONS SELECTIONS AVAILABLE/COMMENTS Calls up the "POWER SUPPLY" window. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. (*): Only Dual Drive version 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 121 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.31. "FLO 2 MODULATOR" window This window is called up by pressing the "NEXT SCREEN" control keys in the "MODULATOR FLO 1" window. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. It displays the MediaFLO modulator card parameters used in the exciter. MESSAGES FUNCTIONS SELECTIONS AVAILABLE/COMMENTS Gives the name windows Displays actual values of the modulation ♦ parameters. Infra ID: This value is inserted into the infrastructure ID field of the Local system parameters message. The network sets this field to the identifier assigned to the local area infrastructure. ♦ LT Offset: This value is inserted into the local time offset field of the local system parameters message. ♦ Daylight: ON / OFF This indicator is inserted into the daylight field of the local system parameters message. ON: Local transmitter time is daylight saving time. Displays actual values of the channelizer ♦ parameters. Nat Len: Exciter initialization register indicates National Length. ♦ Loc Len: Exciter initialization register indicates Local Length. ♦ PP Len: Exciter initialization register indicates Positioning Pilot Length. ♦ Fr1 Len: Exciter initialization register indicates FrameLength. ♦ WID Val: Exciter initialization register indicates WID scrambler sequence number. ♦ LID Val: Exciter initialization register indicates LID scrambler sequence number 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 122 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators MESSAGES FUNCTIONS SELECTIONS AVAILABLE/COMMENTS Indicates which exciter data are displayed EXC A / EXC B (*) (*): Only Dual Drive version CONTROL KEYS FUNCTIONS SELECTIONS AVAILABLE/COMMENTS Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Calls up data from the other exciter (*). Calls up the "FLO 1 MODULATOR" window. Calls up the "STATUS" window. Calls up the "CONTROL LEVEL 1" window. Calls up the "EXCITER Level 1" window. Calls up the "AMPLIFIERS" window. Calls up the «INTERLOCK» window Calls up the "POWER SUPPLY" window. (*): Only Dual Drive version 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 123 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.32. "COFDM MODULATOR" window This window is called up by pressing the "MODUL" control keys in the "EXCITER PANEL" window (SD transmitters) or in the "EXCITER Level 2" window (DD transmitters). It displays the status of the modulator parameters of the exciter. This window is not available in 8VSB modulator unit (ATSC Transmitters). Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. OPTIMUM FAMILY OR ULTIMATE FAMILY CONTROL KEYS AFFINTY FAMILY FUNCTIONS DISPLAY/COMMENTS Calls up the " SFN DELAYS" window. Control key invisible in MFN mode operation. Calls up the "MODULATOR CONFIGURATION" window. Calls up window. the "MODULATOR STATUS" Calls up the "MIP DATA" window. Control key invisible in MFN mode operation. Calls up the "TRANSMITTER STATUS" window. Calls up the "CONTROL Level 1" window. Calls up the "EXCITER Level 2" window (for a Double Drive transmitter) or the "EXCITER PANEL" window (for a Single Drive transmitter). Calls up the "AMPLIFIERS" window. (a) 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 124 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Calls up the " SFN DELAYS" window. Control key invisible in MFN mode operation. Calls up the "MODULATOR CONFIGURATION" window. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Calls up window. the "MODULATOR STATUS" Calls up the "MIP DATA" window. Control key invisible in MFN mode operation. Calls up the «INTERLOCK» window (a) Calls up the "POWER SUPPLY" window. (a) Calls up the "AFFINITY" window. (b) (a): Not Visible for AFFINITY family (b): Not Visible for OPTIMUM or ULTIMATE families MESSAGE FUNCTIONS DISPLAY/COMMENTS Gives the window name. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 125 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.33. "ADAPT PARAMETERS" window This window is called up by pressing the "ADAPT" control keys in the "EXCITER PANEL" window (SD transmitters) or in the "EXCITER Level 2" window (DD transmitters). It displays the status of the ADAPTive parameters of exciter A or B. MODAP VERSION Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. OPTIMUM FAMILY OR ULTIMATE FAMILY AFFINTY FAMILY SIRIUS VERSION OPTIMUM FAMILY OR ULTIMATE FAMILY OTHER MODULATOR CONTROL KEYS MEDIAFLO MODULATOR FUNCTIONS DISPLAY/COMMENTS Calls up data from the other exciter. (*) Calls up the "TRANSMITTER STATUS" window. Calls up the "CONTROL Level 1" window. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 126 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Calls up the "EXCITER Level 1" window or the "EXCITER PANEL" window. Calls up the "AMPLIFIERS" window. (a) Calls up the «INTERLOCK» window (a) Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Calls up the "POWER SUPPLY" window. (a) Calls up the "AFFINITY" window. (b) (*) Only in Double Drive Version. (a): Not Visible for AFFINITY family (b): Not Visible for OPTIMUM or ULTIMATE families MESSAGES FUNCTIONS DISPLAY/COMMENTS Gives the window name. Indicates the status of the linearity correction ♦ MODAP version (Adaptive Linear Equaliser). LIN. COR N. FITTED/ LIN. COR ON LINE / LIN. COR BYPASSED ♦ SIRIUS version LIN. COR ON LINE / LIN. COR BYPASSED Displays the type of linearity correction performed by the ALE card of the EXCITER (fixed or adaptive). LIN. COR FIXED / LIN. COR ADAPTATIVE Indicates the status, ON LINE or BYPASSED, of the non linearity correction (Look Up Table). N. LIN COR ON LINE / N. LIN COR BYPASSED Displays the type of non linearity correction performed by the LUT module of the EXCITER (fixed or adaptive). N. LIN. COR FIXED / N. LIN. COR ADAPTATIVE In fixed position, the correction parameters are not continuously adjusted. In fixed position, the correction parameters are not continuously adjusted. Indicates the status of the digital filter ♦ MODAP version correction. DIG. FILT NOT FITTED / DIG. FILT ON LINE / DIG. FILT BYPASSED ♦ SIRIUS version DIG. FILT ON LINE / DIG. FILT BYPASSED Displays the reference table of the digital filter (1 to 5). Displays whether a Double ASI input is present or absent in the EXCITER unit. 45321648.01 Numéro / Number 108 Doc. DASI FITTED / DASI N. FITTED 9932 V2 Checked Rev. Langu. 27/06/2006 127 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators MESSAGES FUNCTIONS DISPLAY/COMMENTS Gives the window name. Indicates the status of the linearity correction ♦ MODAP version (Adaptive Linear Equaliser). LIN. COR N. FITTED/ LIN. COR ON LINE / LIN. COR BYPASSED ♦ SIRIUS version Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. LIN. COR ON LINE / LIN. COR BYPASSED Displays the type of linearity correction performed by the ALE card of the EXCITER (fixed or adaptive). LIN. COR FIXED / LIN. COR ADAPTATIVE Indicates the status, ON LINE or BYPASSED, of the non linearity correction (Look Up Table). N. LIN COR ON LINE / N. LIN COR BYPASSED Displays the type of non linearity correction performed by the LUT module of the EXCITER (fixed or adaptive). N. LIN. COR FIXED / N. LIN. COR ADAPTATIVE In fixed position, the correction parameters are not continuously adjusted. In fixed position, the correction parameters are not continuously adjusted. Indicates the status of the digital filter ♦ MODAP version correction. DIG. FILT NOT FITTED / DIG. FILT ON LINE / DIG. FILT BYPASSED ♦ SIRIUS version DIG. FILT ON LINE / DIG. FILT BYPASSED (1) Displays whether an OLDC unit is present or absent in the MODAP unit. OLDC FITTED / OLDC N. FITTED Displays which type of modulator processes the input signal. IFIQ BOARD / COFDM EXT 8MHz / COFDM EXT 7MHz / COFDM BOARD 8MHz / COFDM BOARD 7MHz / COFDM BOARD 6MHz / 8VSB BOARD / MediaFLO Indicates which exciter data are displayed.(*) EXC A / EXC B (*) Only in Double Drive Version. (1) Only in MODAP version with OLDC 45321648.01 Numéro / Number 108 Doc. Note: The “ OLDC ” key in “ADAPT STATUS” window is not available (not visible) when the EXCITER type is SIRIUS. 9932 V2 Checked Rev. Langu. 27/06/2006 128 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.34. "DASI STATUS" window This window is called up by pressing the "DASI" control keys in the "EXCITER PANEL" window (SD transmitters) or in the "EXCITER Level 2" window (DD transmitters). It displays the status of the double ASI input parameters of Exciter A or B. MODAP VERSION Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. OPTIMUM FAMILY OR ULTIMATE FAMILY AFFINTY FAMILY SIRIUS VERSION CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Calls up the "CONTROL Level 1" window. Calls up the "EXCITER Level 2" window (for a Double Drive transmitter) or the "EXCITER PANEL" window (for a Single Drive transmitter). Calls up the "AMPLIFIERS" window. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 129 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Calls up the "AMPLIFIERS" window. (a) Calls up the «INTERLOCK» window (a) Calls up the "POWER SUPPLY" window. (a) Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Calls up the "AFFINITY" window. (b) Calls up data from the other exciter. (*) Selects the Transport Stream to be connected to the SIRIUS Exciter . (1) Cancels a selection. (1) Validates a selection. (1) (*) : Only Dual-Drive version. (1) : Only SIRIUS version. (a): Not Visible for AFFINITY family (b): Not Visible for OPTIMUM or ULTIMATE families INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Gives the window name. Indicates the status of the Dual ASI input. Indicates the overall status of the Dual ASI input. Indicates which ASI input is operating. TS 1 / TS 2 Indicates if DASI function is operating. (**) BRA ON: the BRA function is operating, the actual mode of the network is MFN SFN OFF: If the transmitter is on SFN mode, the BRA function is ineffective Indicates the Transport Stream selected. TS 1 / TS 2 Flashes until the "MAIN TS" command is either validated or cleared. Indicates presence or absence of an MPEG1 input signal on the exciter. (1) TS 1 OK / TS 1 MISSING Indicates presence or absence of an MPEG2 input signal on the exciter. (1) TS 2 OK / TS 2 MISSING 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 130 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Indicates presence or absence of an MPEG3 input signal on the exciter. (1) (2) TS 3 OK / TS 3 MISSING Indicates presence or absence of an MPEG4 input signal on the exciter. (1) (2) TS 4 OK / TS 4 MISSING Indicates presence or absence of an synchronization of MPEG input signal on the exciter. (1) (3) SYNC OK / SYNC MISSING This key in “DASI STATUS” window is not available (not visible) when the optional card (Extension Input) is not present. This key in “DASI STATUS” window is not available (not visible) when the optional card (Extension Input) is not present. SYNC OK: The MPEG is synchronized or there is a loss of one frame. SYNC MISSING If a loss of frame condition persists for 2 consecutive frames, the synchronization status is declared MISSING. If 7 occurrences of the transport stream framing byte is detected in the proper place the status is declared OK Indicates which exciter data are displayed. (*) EXC A / EXC B (*) : Dual-Drive version Only. (**) : MODAP version Only. (1) : SIRIUS version Only. (2) : Unavailable with MediaFLO modulator. (3) : MediaFLO modulator only. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 131 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.35. "OLDC STATUS" window, MODAP version ONLY This window is called up by pressing the "OLDC" control keys in the "EXCITER PANEL" window (SD transmitters) or in the "EXCITER Level 2" window (DD transmitters). NOTE : This window is available in MODAP version only It displays the status of the OLDC parameters of Exciter A or B. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. OPTIMUM FAMILY OR ULTIMATE FAMILY CONTROL KEYS AFFINTY FAMILY FUNCTIONS DISPLAY/COMMENTS Calls up the "CONTROL Level 1" window. Calls up the "EXCITER Level 2" window (for a Double Drive transmitter) or the "EXCITER PANEL" window (for a Single Drive transmitter). Calls up the "AMPLIFIERS" window. (a) Calls up the «INTERLOCK» window (a) Calls up the "POWER SUPPLY" window. (a) Calls up the "AFFINITY" window. (b) Calls up the "TRANSMITTER STATUS" window. Calls up data from the other exciter. (*) Displays the measured I/Q amplitude error value. 45321648.01 Numéro / Number 108 Doc. Available in Adaptive mode only. 9932 V2 Checked Rev. Langu. 27/06/2006 132 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators Displays the measured central frequency rejection value. Available in Adaptive mode only. (a): Not Visible for AFFINITY family (b): Not Visible for OPTIMUM or ULTIMATE families INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Gives the window name. Displays whether an OLDC card is present or absent. FITTED / NOT FITTED Indicates the status of the OLDC card. OK / FAULT / MISSING Displays the current operating mode of the OLDC card. ADAPTATIVE / FIXED Indicates which exciter data are displayed. EXC A / EXC B (*) (*) : Only Dual-Drive version. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 133 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.36. "SETTINGS" window, SIRIUS version ONLY This window is called up by pressing the "SETTING" control keys in the "EXCITER PANEL" window (SD transmitters) or in the "EXCITER Level 2" window (DD transmitters). NOTE: This window is available in SIRIUS version only. This window is available in Maintenance mode only. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. OPTIMUM FAMILY OR ULTIMATE FAMILY CONTROL KEYS AFFINTY FAMILY FUNCTIONS DISPLAY/COMMENTS Calls up the " RESERVE ADAPTATIVITY SETTING" window. Control key configuration. invisible in Dual Drive Calls up the "PREAMPLI SETTING" window. Calls up the "AGC SETTING" window. Calls up the "LOCAL / IMAGE REJECT" window. Calls up window. the "ADJUSTMENT Calls up the "LINear CALIBration" window. 10Mhz" CORrection Calls up the "TRANSMITTER STATUS" window. Calls up the "CONTROL Level 1" window. Calls up the "EXCITER Level 2" window (for a Double Drive transmitter) or the "EXCITER PANEL" window (for a Single Drive transmitter). 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 134 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Calls up the "AMPLIFIERS" window. (a) Calls up the «INTERLOCK» window (a) Calls up the "POWER SUPPLY" window. (a) Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Calls up the "AFFINITY" window. (b) (a): Not Visible for AFFINITY family (b): Not Visible for OPTIMUM or ULTIMATE families MESSAGE FUNCTIONS DISPLAY/COMMENTS Gives the window name. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 135 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.37. "RESERVE ADAPTATIVITY SETTINGS" window, SIRIUS version ONLY This window is called up by pressing the "ADAPT RESERVE" control keys in the "SETTINGS" window. NOTE : This window is available in SIRIUS version only This window is only available in Maintenance mode and in Dual Drive configuration transmitter The window allows to configure the state of the not linear corrections and to display that current for the reserve exciter. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. OPTIMUM FAMILY OR ULTIMATE FAMILY CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Controls the loading of the linear correction with flat filter coefficients. Press this key and validation allows verifying the good operating WITHOUT correction. Note: To feedback to old coefficients used the function RECALL of the control key “ADAPT PARAM” Controls the loading of the no linear correction with flat filter coefficients. Press this key and validation allows verifying the good operating WITHOUT correction. Note: To feedback to old coefficients used the function RECALL of the control key “ADAPT PARAM” 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 136 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Selects the coefficients of the corrections for reserve exciter Press this control key and validation: ♦ SAVE : Allows saving coefficients into tables of corrections. ♦ RECALL: Allows verifying the good operating WITH corrections by using coefficients beforehand recorded during the equipment line-up procedure: Recalls the coefficients of the last save. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Validates a selection. Cancels a selection. Calls up the "SETTINGS" window. INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Give the window name. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 137 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.38. "PREAMPLI SETTING" window, SIRIUS version ONLY This window is called up by pressing the "PREAMP" control keys in the "SETTINGS" window. NOTE : This window is available in SIRIUS version only Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. This window is only available in Maintenance mode. It displays the status of RF preamplifier parameters of exciter A or B. Figure 30 : Exciter on Antenna ( D.D.) CONTROL KEYS Figure 31 : Exciter on Dummy load ( D.D.) FUNCTIONS DISPLAY/COMMENTS Validates a selection. Cancels a selection. Set the reference value of the threshold in the RF preamplifier. Only available for the exciter on antenna Flashes until the “SET REFER”” command is either validated or cleared. Appelle les données de l’autre EMB (*). Calls up the "SETTINGS" window. INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Give the window name. Displays the transmitted RF power value. This value is expressed in a percentage of calibrated power value. Displays the current value of the output preamplifier that is applied to the RF chain of the transmitter. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 138 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Displays the fault threshold value of the RF preamplifier. Indicates which exciter data are displayed EXC A / EXC B (*). Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. (*): Only Dual Drive version. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 139 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.39. "AGC SETTING" window, SIRIUS version ONLY This window is called up by pressing the "AGC" control keys in the "SETTINGS". NOTE : This window is available in SIRIUS version only. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. This windows is available in Maintenance mode only. It displays the status of the AGC parameters of Exciter A or B. Figure 32 : Exciter on air for Transmitter D.D. CONTROL KEYS Figure 33 : Exciter on load for Transmitter D.D. FUNCTIONS DISPLAY/COMMENTS Selects the GAIN control mode automatic) for AGC of the transmitter (manual or Command is disabled while the PCL is locked (disabled). Validates a selection. Cancels a selection. Calls up the "SETTING" window. Set the reference value in Auto Gain Control (AGC) loop. Available with on-air exciter only. Calls up the “NUMERICAL VALUE” window in which the Main Gain Control value (MGC) can be changed Command is disabled while the PCL is locked (disabled). Displays the attenuation value Warning: This attenuator adjusts the output power in manual gain of the transmitter. Flashes until the “SET REFER”” command is either validated or cleared. It’s to be expressed in dB. The maximum attenuation is 25.0 Calls up the “NUMERICAL VALUE” window in which the LIMITOR value can be changed Command is disabled while the PCL is locked (disabled). Displays the attenuation value Warning: This attenuator limits the RF output of SIRIUS Exciter. It’s to be expressed in dB. The maximum attenuation is 25 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 140 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators Calls up data from the other exciter. (*) INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Gives the window name. Displays, which gain control mode (MANUAL or AUTOMATIC) is currently picked up by the transmitter GAIN MANUAL / GAIN AUTO Indicates the status of the AGC loop. AGC OK / AGC FAULT FAULT: The AGC voltage is out of the operation range:+-2dB (0,5V to 2,5V) regarding AGC reference. It’s displays in “AGC SETTING” screen. Displays which gain control mode is selected AUTO / MANUAL Flashes until the “GAIN”” command is either validated or cleared. Displays the transmitted RF power value This value is expressed in a percentage of the calibrated power value. Displays the current value for the Auto Gain Control (AGC) loop that is picked up by the transmitter. Displays the reference value in Auto Gain Control (AGC) that is used. Indicates the level of the feedback signal for Linear Correction (Ripple) Green indication: OK Red indication: FAULT The RF feedback level is out of the range: FLO or COFDM modulator used: typical –10dBm to 0dBm 8VSB modulator used: typical –15dBm to +2dBm Indicates the level of the feedback signal for Linear Correction (Shoulder) Green indication: OK Red indication: FAULT The RF feedback level is out of the range: FLO or COFDM modulator used: typical –10dBm to 0dBm 8VSB modulator used: typical –15dBm to +2dBm Indicates which exciter data are displayed. EXC A / EXC B (*) (*) : Only Dual-Drive version. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 141 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.40. "LOCAL/IMAGE REJECT" window, SIRIUS version ONLY This window is called up by pressing the "REJECT" control keys in the "SETTINGS" window. NOTE : This window is available in SIRIUS version only. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. This window is only available in maintenance mode. CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Decrements the adjustment value of the “OFFSET I” by step of 1 or by step of 10. Allows to adjust the I & Q/RF modulator (Local Oscilator Rejection) Displays the adjustment value of the “OFFSET I” Increments the adjustment value of the “OFFSET I” by step of 1 or by step of 10. Obtain the maximum rejection of the local frequency (<35dB). The adjustments are directly applied to the basic transmitter. Decrements the adjustment value of the “OFFSET Q” by step of 1 or by step of 10. Displays the adjustment value of the “OFFSET Q” Increments the adjustment value of the “OFFSET Q” by step of 1 or by step of 10. Decrements the adjustment value of the GAIN by step of 1 or by step of 10. Allows to adjust the rejection of the unwanted lateral band (image Rejection) Displays the adjustment value of the GAIN. The adjustments are directly applied to the basic transmitter. Increments the adjustment value of the GAIN by step of 1 or by step of 10. Decrements the adjustment value of the PHASE by step of 1 or by step of 10. Displays the adjustment value of the PHASE. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 142 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Increments the adjustment value of the PHASE by step of 1 or by step of 10. Allows saving adjustments above in the basic transmitter. Flashes until the “SAVE” command is either validated or cleared. Validates a selection. Cancels a selection. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Calls up data from the other exciter. (*) Calls up the "SETTINGS" window. INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Gives the window name. Indicates which exciter data are displayed. EXC A / EXC B (*). (*) : Only Dual-Drive version. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 143 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.41. "10 MHz ADJUSTEMENT" window, SIRIUS version ONLY This window is called up by pressing the "PLL 10MHz" control keys in the "SETTINGS" window. NOTE: This window is available in SIRIUS version only. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. This window is only available in Maintenance mode. CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Decrements the adjustment value of the frequency 10Mhz internal by step of 1 or by step of 10. Allows to adjust the frequency 10MHz if the choice " INTERNAL CLOCK " was selected, we have then the message " MANUAL ADJUSTMENT ". Displays the adjustment value of the frequency 10Mhz internal. Increments the adjustment value of the frequency 10Mhz internal by step of 1 or by step of 10. Allows saving adjustments above in the basic transmitter. The manual adjustment of the frequency is possible whatever the state (present or absent) in signals 1PPS or 10Mhz. Flashes until the “SAVE”” command is either validated or cleared. Validates a selection. Cancels a selection. Calls up data from the other exciter. (*) Calls up the "SETTING" window. INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Gives the window name. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 144 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Indicates which exciter data are displayed. EXC A / EXC B (*). Displays the status of 10 Mhz adjustment MANUAL ADJUSTMENT / according to the clock configuration AUTO ADJUSTMENT chosen for the exciter (“Modulator ♦ MANUAL ADJUSTMENT: The choice of configuration” window) operating " INTERNAL CLOCK " has been selected. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. ♦ AJUSTEMENT AUTO : The choice of operating " EXTERNAL GPS or EXTERNAL CLOCK " has been selected. So control keys of this window are without action. (*) : Only Dual-Drive version. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 145 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.42. "LINEAR CORRECTION CALIBRATION" window, SIRIUS version ONLY This window is called up by pressing the "LIN COR CALIB." control keys in the "SETTINGS" window. NOTE : This window is available in SIRIUS version only. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. This window is available in Maintenance mode only. It allows calibrating the linear correction feedback of Exciter A or B. CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Starts the correction of the Linear correction BECAREFULL: Achieve assembling circuit before electrical Pressing this control key et validation allows to start the calibration. Duration of the Calibration. 3 to 5 minutes Selects the calibration coefficients of the linear correction Press this validation: control key and ♦ SAVE: Allows saving actual coefficients into table. ♦ RECALL: Recalls the coefficients of the last save Calls up data from the other exciter. (*) Validates a selection. Cancels a selection. Calls up the "SETTING" window. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 146 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Gives the window name. Indicates which exciter data are displayed. EXC A / EXC B (*) Displays the calibration progress. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. (*) : Only Dual-Drive version. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 147 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.43. "SFN DELAY" window This window is called up by pressing the "SFN" control keys in the "MODULATOR" window. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. This windows displays the status of the delays necessary for SFN mode operation of Exciter A or B. This windows is available in SFN mode only. It is not available in 8VSB modulator unit (ATSC Transmitters). CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Calls up data from the other exciter. (*) Calls up the "MODULATOR" window. MESSAGES FUNCTIONS DISPLAY/COMMENTS Gives the parameter name. Indicates the SFN status. SFN ON / OFF Indicates the GPS monitoring status. GPS ON / OFF Displays the transmitter identification number. Gives the parameter name when the transmitter is in SFN mode. Displays the NETWORK delay value in SFN mode. 45321648.01 Numéro / Number 108 Doc. This value can be changed by the MIP. 9932 V2 Checked Rev. Langu. 27/06/2006 148 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators MESSAGES FUNCTIONS DISPLAY/COMMENTS Displays the EQUALISER delay value. This value is calculated by the modulator unit. The different delays are related as follows : Delays (MAX + OFFSET) = Delays (NETWORK + EQUALISER +TRANSMITTER) Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. Displays the TRANSMITTER delay value. (*) Displays the MAXIMUM delay value in SFN mode. This value can be changed by the MIP. Displays the offset delay value when the transmitter is in SFN mode. This value can be changed by the MIP and / or by Local Control Panel window. Indicates which displayed. EXC A / EXC B exciter data are (*) : Dual-Drive version only. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 149 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.44. "MODULATOR CONFIG" window This window is called up by pressing the "CONFIG" control keys in the "MODULATOR" window. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. It displays the status of the DVB-T modulator configuration parameters of exciter A or B. This window is available with an internal COFDM modulator only (DVB-T Transmitters). CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Calls up data from the other exciter. (*) Calls up the "MODULATOR" window. (*) : Only Dual-Drive version INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Gives the window name. Displays the constellation type used by the modulator. CONSTEL 64-QAM/16-QAM/QPSK 64-QAM : 64-bit representation 16-QAM : 16-bit representation QPSK (4-QAM) : 4-bit representation Displays the band width. WIDTH 8 MHz / 7 MHz / 6 MHz Displays the guard interval used by the COFDM modulator. INTERVAL 1/32; 1/16; /1/8; 1/4 Displays the High Priority code rate of the modulation. HP CODE RATE 7/8; 5/6; 3/4; 2/3; 1/2 Displays the number of transmitted carriers. CARRIER 8K / 2K Displays the input configuration of the modulator. Data PRBS 15, Data PRBS 17, Data PRBS 20, Data PRBS 23, Data input ASI, Data DVB_SPI 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 150 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Displays the configuration of the MODAP clock. CLOCK internal, CLOCK external, CLOCK data derived Indicates which exciter data are displayed. EXC A / EXC B (*) Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. (*) : Only Dual-Drive version 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 151 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.45. "MODULATOR STATUS" window This window is called up by pressing the "STATUS" control keys in the "MODULATOR" window. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. It displays the status of the DVB-T modulator configuration parameters of exciter A or B. This window is only available with an internal COFDM modulator (DVB-T Transmitters). CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Calls up data from the other exciter. (*) Calls up the "MODULATOR" window. (*): Only Dual-Drive version INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Gives the window name. Displays the Reset status of the modulator. "No Reset" is displayed when: the internal COFDM modulator has not been affected by a mains failure. the internal COFDM modulator has not been affected by a reset which was not commanded by the DAP unit. "Reset Done" is displayed when: the internal COFDM modulator has been affected by a reset which was not commanded by the DAP unit. the COFDM power supply is shut down, but the DAP power supply is present. Displays the input interface status of the modulator. 45321648.01 Numéro / Number 108 Doc. TS (interface) toggling / TS (interface) stuck 9932 V2 Checked Rev. Langu. 27/06/2006 152 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. INDICATOR LAMPS AND MESSAGE DISPLAYS FUNCTIONS DISPLAY/COMMENTS Displays the input signal of the modulator. Data PRBS 15 / Data PRBS 17 / Data PRBS 20 / Data PRBS 23 / Data input ASI / Data DVB_SPI Displays the internal status of the modulator. Correct / Internal fault Displays the synchronisation status of the clock with respect to the Transport Stream. Clock coherent / PLL unlocked / Clock not coherent Displays the type of clock used. CLOCK internal, CLOCK external, CLOCK data derived Displays the status of configuration. CFG done / CFG underway / CFG fault Displays the SFN mode operation.status SFN ON / SFN OFF Displays the status of the modulator. Not configured / Configured / CFG fault Not configured : The modulator does not requested configuration. Displays the Transport Stream status. TS status normal / abnormal Displays the GPS status. GPS missing / GPS présent accept the GPS missing : The 10 MHz and/or 1 PPS reference signals are missing. Displays the output interface status of the modulator. IQ outputs toggling / IQ outputs stuck Indicates which exciter data are displayed. EXC A / EXC B (*) (*) : Only Dual-Drive version. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 153 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.46. "MODULATOR - MIP" window This window is called up by pressing the "MIP" control keys in the "MODULATOR" window. Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. This window displays the MIP data contained in the Transport Stream. This windows is available in SFN mode only. It isn’t available in 8VSBB modulator unit (ATSC Transmitters). CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Calls up data from the other exciter. (*) Calls up the "MODULATOR" window. MESSAGE FUNCTIONS DISPLAY/COMMENTS Gives the window name. Displays the RF synthesizer frequency offset value. Displays the output RF power offset value. The typical output power level is 0 dB (value of the required power). Displays the offset delay value contained in the MIP when the transmitter is in SFN mode. Indicates which displayed.(*) exciter data are EXC A / EXC B 108 Checked Rev. Langu. 27/06/2006 (*) : Only Dual-Drive version. 45321648.01 Numéro / Number Doc. 9932 V2 154 / 192 Page Digital Liquid Cooled UHF TV Equipment Use of commands and description of indicators 2.1.47. "RF AMPLIFIERS" window, 6 current values (OPTIMUN / ULTIMATE FAMILY) This window is called up by the "AMPLI" command in the other windows. It displays the status of an RF amplifier. Notes : An amplifier which is not included in the transmitter configuration can not be accessed by the keys "± AMPLI". Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON. A cabinet which is not included in the transmitter configuration can not be accessed by the "± CAB" control keys. POWER AMPLIFIER T1 T2 T6 T5 T3 T4 Amplifier modules With transistors CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS Decrements the cabinet number. The number resulting from the decrêmentation is displayed in the message window between the "+ CAB" and "- CAB" control keys. (*) Command is disabled while the PCL is locked (disabled). Increments the cabinet number. The number resulting from the incrementation is displayed in the message window between the "+ CAB" and "- CAB" control keys. (*) Command is disabled while the PCL is locked (disabled). (**) Decrements the amplifier number in a particular cabinet. The number resulting from the decrementation is displayed in the message window between the "+ AMPLI" and "- AMPLI" control keys. Command is disabled while the PCL is locked (disabled). (**) Increments the amplifier number in a particular cabinet. The number resulting from the incrementation is displayed in the message window between the "+ AMPLI" and "- AMPLI" control keys. Command is disabled while the PCL is locked (disabled). Calls up the "TRANSMITTER STATUS" window. Calls up the "CONTROL Level 1" window. 45321648.01 Numéro / Number 108 Doc. 9932 V2 Checked Rev. Langu. 27/06/2006 155 / 192 Page
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 39 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:063a0726-90cd-44b7-82d5-03454a039818 Modify Date : 2006:07:07 13:21:24-04:00 Create Date : 2006:07:07 13:21:12-04:00 Metadata Date : 2006:07:07 13:21:24-04:00 Document ID : uuid:0f589dea-6c0c-4c1e-af94-690ca88b4d6c Format : application/pdf Tagged PDF : Yes Title : PREIMPAP.DOC Creator : Acrobat PDFMaker 6.0 pour Word Author : TBM Subject : Instructions de formatage du modle PREIMPAP.DOT Producer : Acrobat Distiller 6.0 (Windows)EXIF Metadata provided by EXIF.tools