Thomson Broadcast and Multimedia ULT-1K10K2 UHF Digital transmitter, for use with MediaFlo User Manual PREIMPAP

Thomson Broadcast & Multimedia, Inc. UHF Digital transmitter, for use with MediaFlo PREIMPAP

User Manual part 2

Download: Thomson Broadcast and Multimedia ULT-1K10K2 UHF Digital transmitter, for use with MediaFlo User Manual PREIMPAP
Mirror Download [FCC.gov]Thomson Broadcast and Multimedia ULT-1K10K2 UHF Digital transmitter, for use with MediaFlo User Manual PREIMPAP
Document ID690676
Application IDnHX02M5ukCzO96pWiHHkRw==
Document DescriptionUser Manual part 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize162.74kB (2034308 bits)
Date Submitted2006-08-07 00:00:00
Date Available2006-10-12 00:00:00
Creation Date2006-07-07 13:20:07
Producing SoftwareAcrobat Distiller 6.0 (Windows)
Document Lastmod2006-07-07 13:20:21
Document TitlePREIMPAP.DOC
Document CreatorAcrobat PDFMaker 6.0 pour Word
Document Author: TBM

Digital Liquid Cooled UHF
TV Equipment
Exploitation
1.12.2. Access to logbook
This procedure controls the facilities for sending a list of the various operational events to a terminal
connected to the CPU. These data can be sent :
♦ continuously in real time or,
♦ when requested by the operator.
The operation is controlled from the "LOGBOOK" window and is only possible if maintenance mode
has been selected and if the PCL is unlocked, i.e. enabled.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
ACTION
RESULT
Having selected the
"LOGBOOK" window
♦
The "TRACE ON"/"TRACE OFF" control keys
indicates the method of sending data currently
selected.
♦
«TRACE ACTIVE» : sends the data in real time.
♦
«TRACE INHIBEE» :
operator request.
sends
the
data
after
To change the
method of sending
data:
♦
Press on the "TRACE ON" key or the ♦
"TRACE OFF" key.
Sends the data after
operator request.
♦
Having selected "TRACE OFF":
♦
Sends data on all operational events.
•
Press "DISPLAY ALL",
♦
•
Sends data on the 20 operational events previous
to the last events listed in the logbook.
Press on the "PAGE UP" key,
♦
•
Press on the "PAGE DOWN" key.
Sends data on the 20 operational events which
follow on from the last events listed in the
logbook.
45321648.01
Numéro / Number
108
Doc.
The "TRACE ON"/"TRACE OFF" control keys
indicates the new method of sending the data.
9932 V2
Checked
Rev.
Langu.
27/06/2006
39 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2. Use of commands and description of indicators
2.1. Use and description of control panel screens
2.1.1.
Outline
The various windows displayed on the Local Control Panel (PCL) provide the operator with the
following:
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
♦ Transmitter status data,
♦ Commands to change the operational state of the system, and commands to select the various
windows.
NOTE :
The following windows are not available with an ATSC transmitter:
♦ SFN delay
♦ Modulation configuration
♦ Modulator status
♦ MIP data
♦ Modulator input setting
There are used in DVB-T transmitters only.
Ergonomics of screens
♦ Ergonomics of control keys :
• Text of browsing keys is yellow on blue background
• Text of changing and confirming keys is black on
white background
♦ Ergonomics of message and information :
• Unmodifiable message is black on cyan blue
background
• Modifiable message
background
is
cyan
blue
45321648.01
Numéro / Number
on
108
Doc.
black
9932 V2
Checked
Rev.
Langu.
27/06/2006
40 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
• Modifiable information is black on green, red, orange, yellow background
- Normal state is on green background
- Abnormal state but without default is on yellow
background
- Default state due to sub-assemblies is on red
background
- External default which concern sub-assemblies is
on orange background
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
- Special case
Information « MAINT MODE / NORMAL MODE » is
flashing on yellow background
The reference of the touch screen software is 29 709 093.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
41 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.2.
2.1.2.1.
Installation windows
"INSTALLATION PARAMETERS Level 1" window
This window appears when the changeover switch SW1 on the exciter/CPU interconnection card
(MODAP version) or on the management system interconnection card (SIRIUS version), is switched
so that the dot is visible and that CPU board is reset.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
This window is used to change the transmitter configuration parameters stored in the CPU board.
CONTROL KEYS
FUNCTIONS
SELECTIONS
AVAILABLE/COMMENTS
VHF I, VHF III, UHF
Selects the transmitter frequency range.
Displays last selection.
Displays the RF synthesiser frequency value.
Displays last selection.
Selects the maximum transmitter power
(Maximum available RF power).
Displays last selection.
Selects the actual
(Calibrated RF power)
transmitter
power
Displays last selection.
Pressing this key calls up the "NUMERICAL
VALUE" window in which this frequency can
be changed.
Pressing this key calls up the "NUMERICAL
VALUE" window in which this typical
transmitter power can be changed.
Power level for which probes and power
output displays (bargraph) of the transmitter
are adjusted.
This level is a reference for the software.
This actual value is associated with the
power levels in % “100”, display in window,
and with the Auto Gain value “128” (Digital
transmitter) of ADAPT exciter.
At any time: CAL Power < MAX Power
Selects the language of the Local Control
Panel windows.
FRANCAIS, ENGLISH, ESPAGNOL
Displays last selection.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
42 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
CONTROL KEYS
FUNCTIONS
SELECTIONS
AVAILABLE/COMMENTS
Selects the cooling type of the cabinet.
AIR COOLING, LIQUID COOLING
Displays last selection.
Selects the exciter configuration.
SINGLE EXCITER, DUAL
PASSIVE RESERVE, N+1
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Displays last selection.
EXCITER,
Selects the type of power unity.
DISPLAY IN dB/W, DISPLAY IN %
Displays last selection.
If “%” is elected, every RF power display is to
be expressed in %, except maximum power
which is expressed in Watts.
If “dB” is elected, every RF power display is
to be expressed in dB, except maximum
power which is expressed in Watts.
Selects the
transmitter.
modulation
type
of
the
ANALOG. TRANSMIT;
DIGITAL TRANSMIT
Displays last selection.
Adapts the CPU software to suit the safety
interface hardware.
COOLING LOAD NOT FITTED
COOLING LOAD FITTED
FITTED : The safety of the load network
cooling is active. The "COOLING LOAD" key
is visible in "INTERLOCK" window.
Adapts the CPU software to suit the low
power alarm status.
TS ALARM DISABLE,
TS ALARM ENABLE
DISABLE : Without input Transport Stream
(TS), there is no low power alarm indication.
ENABLE: Indication low power alarm is
active when the input Transport Stream (TS)
is absence
Adapts the CPU software to suit one
password use for PCL unlocked.
PASSWORD DISABLE,
PASSWORD ENABLE
ENABLE : Using of password for PCL
unlocked
Sets the CPU
configuration.
board
to
the
default
Calls up the "WARNING 2" window.
This control keys may be used to repeat the
installation procedure.
Validates the configuration displayed on the
window.
Calls up the "TRANSMITTER INTERFACE
PARAMETERS" window.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
43 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.2.2.
"TRANSMITTER INTERFACE PARAMETERS" window
This window appears when the changeover switch SW1 on the exciter/CPU interconnection card
(MODAP) or on the management system interconnection card (SIRIUS) is switched so that the dot is
visible and that CPU board is reset.
It is called up by pressing the "INSTALL NEXT" control keys in the "INSTALLATION PARAMETERS
Level 1" window.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
This window is used to change the transmitter interface parameters stored in the CPU card.
CONTROL KEYS
FUNCTIONS
SELECTIONS
AVAILABLE/COMMENTS
Selects the transmitter ID number in N+1 or
Passive Reserve configurations.
The transmitter ID number is used for remote
control through an RS 232/485 connection.
Displays last selection.
Pressing this key calls up the "NUMERICAL
VALUE" window in which this two-digit
identification number can be changed.
Selects the type of JBUS protocol operation
for remote control
JBUS ASCII
JBUS RTU
Displays last selection
Selects the type of remote operation.
SERIAL RMT CTRL, PARALLEL RMT
CTRL, USER RMT CTRL
Displays last selection.
Calls up the "CABINET CONFIGURATION
PARAMETERS" window.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
44 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.2.3.
"CABINET CONFIGURATION PARAMETERS" window
This window appears when the changeover switch SW1 on the exciter/CPU interconnection card
(MODAP) or on the management system interconnection card (SIRIUS), is switched so that the dot is
visible and that CPU board is reset.
It is called up by pressing the "INSTALL NEXT" control keys in the "TRANSMITTER INTERFACE
PARAMETERS" window.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
This window is used to change the cabinet configuration parameters stored in the CPU board.
CONTROL KEYS
FUNCTIONS
SELECTIONS
AVAILABLE/COMMENTS
Validates the cabinet selection and detects
the amplifier location in each of the cabinet
selected.
Cancels the entry and calls back the
previous values
Selects the number of currents measured by
amplifier unit (*).
Displays last selection
45321648.01
Numéro / Number
108
Doc.
AMPLIS 6 TRANS. : 6 currents measured
AMPLIS 8 TRANS. : 8 currents measured
9932 V2
Checked
Rev.
Langu.
27/06/2006
45 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
CONTROL KEYS
FUNCTIONS
SELECTIONS
AVAILABLE/COMMENTS
Selects the type of the cabinet.
NO, MP, B4, B6, B10, B16AG, B16NG, B20,
AFF4, AFF8
Displays last selection
♦
NO: No use
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
OPTIMUM / ULTIMATE FAMILY
♦
MP: MPNG Cabinet,
♦
B4: Cabinet consist of 4 RF amplifiers,
♦
B6: Cabinet consist of 6 RF amplifiers,
♦
B16AG: Cabinet consist of 16 RF
amplifiers (Old generation cabinet: the
main MUX card “MASTER” feed 4 PSUs)
♦
B16NG: Cabinet consist of 16 RF
amplifiers (New generation cabinet: The
main MUX card “MASTER” feed 5 PSUs)
♦
B20: Cabinet consist of 20 RF amplifiers
AFFINITY FAMILY
Calls up the " AMPLIFIER LOCATION "
window
Calls up the "ADAPT
PARAMETERS" window.
(*) Note
♦
AFF4: Cabinet consist of 4 RF amplifiers
♦
AFF8: Cabinet consist of 8 RF amplifiers
This control keys may be used to selected
the amplifier location
INSTALLATION
♦ In case of using the 2400W VHF amplifier unit (61388768 or 61388769) ,the window
‘’RF amplifier’’ include 6 current measurements.
♦ In case of using the 1600W VHF amplifier unit ,the window ‘’RF amplifier’’ include 8
current measurements.
♦ In case of using the UHF amplifier unit , the window ‘’RF amplifier’’ include 6 current
measurements.
MESSAGE
FUNCTIONS
DISPLAY/COMMENTS
Gives the window name.
Displays the detected amplifier location
number including into this cabinet.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
46 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.2.3.1.
"LOCATION AMPLIFIER" window
This window appears when the changeover switch SW1 or S9 is switched so that the dot is visible and
that CPU board is reset.
It is called up by pressing the "DISPLAY " control keys in the " CABINET CONFIGURATION
PARAMETERS" window.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
This window displays the location of RF amplifier in selected cabinet. It is used to change the amplifier
location stored in the CPU board.
CONTROL KEYS
FUNCTIONS
SELECTIONS
AVAILABLE/COMMENTS
Decrements the cabinet number (*).
The
number
resulting
from
the
decrementation is displayed in the message
window between the "+ CAB" and "- CAB"
control keys.
Command is disabled while the PCL is
locked (disabled).
Increments the cabinet number (*).
The
number
resulting
from
the
incrementation is displayed in the message
window between the "+ CAB" and "- CAB"
control keys.
Command is disabled while the PCL is
locked (disabled).
Detects the amplifier location in cabinet
selected.
Validates the entry
Cancels the entry and calls back the
previous windows
Calls up the "CABINET CONFIGURATION
PARAMETERS" window.
(*) : Operating only when there is more than one cabinet.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
47 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
MESSAGE
FUNCTIONS
DISPLAY/COMMENTS
Gives the window name.
Toggles between present and absent or
vision and sound amplifier location
Displays the amplifier location status into this
cabinet
PRES. / ABSENT for digital transmitter
VISION / SOUND. / ABSENT for analogue
transmitter
Displays last selection
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Shows the number of the particular cabinet
to which the data displayed in this window
refer.
2.1.2.4.
"INSTALLATION ADAPT PARAMETERS" window
This window appears when the changeover switch SW1 on the exciter/CPU interconnection card
(MODAP) or on the management system interconnection card (SIRIUS) is switched so that the dot is
visible and that CPU board is reset.
It is called up by pressing the "INSTALL NEXT" control keys in the "CONFIGURATION CABINET"
window.
This window is used to change the configuration adaptation parameters stored in the CPU card.
Note :
♦ MODAP Version only
To set up a new parameter configuration of the modulator, the three corrections (ALE,
LUT and OLDC) should be set to the FIXED mode. The control keys can be defined in
the "MISCELLANEOUS" windows and "CONTROL MAINT Level 4" windows.
♦ SIRIUS Version only
To set up a new parameter configuration of the modulator, the two corrections (ALE, and
LUT) should be set to the FIXED mode. The control keys can be defined in the
"MISCELLANEOUS" windows and "CONTROL MAINT Level 4" windows.
MODAP Version
45321648.01
Numéro / Number
SIRIUS Version
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
48 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
CONTROL KEYS
FUNCTIONS
SELECTIONS AVAILABLE/COMMENTS
Selects the type of modulator processing the
input signal.
Displays last selection.
8VSB BOARD / COFDM EXT /
IFIQ BOARD / COFDM MODAP /
COFDM SIRIUS / FLO SIRIUS
OR
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Selects the band width of the canal for DVBT
signal
(2)
Displays last selection.
BAND WIDTH 6MHz /
BAND WIDTH 7MHz /
BAND WIDTH 8MHz /
This control key is available in COFDM
MODAP or COFDM SIRIUS (Internal DVB-T
Modulator)
Adapts the CPU software to suit the DAP ♦ MODAP version
hardware (Adaptive Linear Equalizer).
LIN. COR NOT FITTED/ LIN. COR ON LINE /
Displays last selection.
LIN. COR BYPASSED
♦
SIRIUS version
LIN. COR ON LINE / LIN. COR BYPASSED
Activates or bypasses the DAP non linearity
corrector (Look Up Table).
N. LIN. COR ON LINE /
N. LIN. COR BYPASSED
Displays last selection.
Adapts the CPU software to suit the DAP ♦ MODAP version
hardware (digital filter).
DIGIT FILT NOT FITTED /
Displays last selection.
DIGIT FILT ON LINE /
DIGIT FILT BYPASSED
♦
SIRIUS version
DIGIT FILT ON LINE /
DIGIT FILT BYPASSED
Selects the table for the digital filter.
Values: 1 to 5
Displays last selection.
This value is defined in factory:
♦
Value normally used on MODAP Exciter is
equal at 5
♦
Value normally used on SIRIUS Exciter is
equal at 1.
Pressing this key calls up the "NUMERICAL
VALUE" window in which this value can be
changed.
Adapts the CPU software to suit the MODAP
hardware (Double ASI input).
(1)
Displays last selection.
Adapts the CPU software to suit the MODAP
hardware (OLDC).
(1)
DASI NOT FITTED / DASI FITTED
OLDC FITTED / OLDC NOT FITTED
Displays last selection.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
49 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
CONTROL KEYS
FUNCTIONS
SELECTIONS AVAILABLE/COMMENTS
Sets the CPU board to the configuration
according to the Americanisation unit
hardware type 37418880
FOLDBACK NOT FITTED,
FOLDBACK FITTED
This option unit must be present so that the
power control on antenna VSWR fault will be
progressively produce through an algorithm.
In the second case that the power control on
antenna VSWR fault will be is produce by
stairway (-3dB, -6dB and halt ‘no power”)
Adapts the CPU software. Visible
COFDM SIRIUS modulator only
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
(2)
on
Displays last selection.
DISABLE: The DVB-H parameters are not
accessible via the DVB-T CONTROL screen.
ENABLE: The DVB-H parameters are
available via the DVB-T CONTROL screen.
Calls up the "ETHERNET INSTALLATION
PARAMETERS" window.
(1) : Available on MODAP version only
(2) : Unavailable on MediaFLO modulator
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
50 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.2.5.
"ETHERNET INSTALLATION PARAMETERS" window
This window appears when the changeover switch SW1 or S9 is switched so that the dot is visible and
that CPU board is reset.
♦ For Digital Transmitter
It is called up by pressing the "INSTALL NEXT" control keys in "INSTALLATION ADAPTATION
PARAMETERS" window.
♦ For Analogue Transmitter
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
It is called up by pressing the "INSTALL NEXT" control keys in "INSTALLATION EXCITER
PARAMETERS" window.
This window is used to change the Ethernet configuration parameters used by the communication
network. It is only available with TH860 CPU Board.
MESSAGE & CONTROL KEYS
FUNCTIONS
SELECTIONS AVAILABLE/COMMENTS
Displays the identification number of
the CPU board
This reference is single and associated to one
CPU board
Used to insert the WEB activation
code.
THALES produces activation code of the
“Agent WEB” option. This code is single and
associated to the identification number of the
CPU board
Displays the WEB activation code,
without option in operation the
control keys displays: “0”
Pressing this key calls up the "NUMERICAL
VALUE" window in which this code value can
be inserted.
Used to insert the SNMP activation
code.
THALES produces activation code of the
“Agent SNMP” option. This code is single and
associated to the identification number of the
CPU board
Displays the SNMP activation code,
without option in operation the
control keys displays: “0”
Pressing this key calls up the "NUMERICAL
VALUE" window in which this code value can
be inserted.
Used to Insert the IP address of the
transmitter in an Ethernet network.
Your network
address.
Displays the IP address in operation.
NOTA : IP wrong address disturbs the
network.
When the Ethernet network is not
operated the control keys must
display: “0.0.0.0”
45321648.01
Numéro / Number
108
Doc.
administrator
gives
the
Calls up the "NUMERICAL VALUE" window
9932 V2
Checked
Rev.
Langu.
27/06/2006
51 / 192
Page
IP
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
MESSAGE & CONTROL KEYS
FUNCTIONS
SELECTIONS AVAILABLE/COMMENTS
Used to Insert the sub-net mask
number
Your network administrator gives the subset
mask number.
Displays the Sub-net mask number
in operation.
This number, associated with IP address,
identifies the network inside your transmitter is.
When the Ethernet network is not
operated the control keys must
display: “0.0.0.0”
NOTA : Subset mask
disturbs the network.
Used to Insert the IP address of
gateway
Your network administrator gives the gateway
IP address.
Displays the IP address of the
gateway in operation.
NOTA : Gateway IP wrong address disturbs
the network.
When the Ethernet network is not
operated the control keys must
display: “0.0.0.0”
Calls up the "NUMERICAL VALUE" window
Used to Insert the IP address of Net
work Time Protocol (NTP) SERVER.
Your network administrator
address of the NTP server.
Displays the IP address in operation.
NOTA : IP wrong address of the NTP server
disturbs the network.
When the Ethernet network is not
operated the control keys must
display: “0.0.0.0”
wrong
number
Calls up the "NUMERICAL VALUE" window
gives
the
Calls up the "NUMERICAL VALUE" window
Calls up the "INSTALLATION
PARAMETERS Level 1" window.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
52 / 192
Page
IP
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.3.
2.1.3.1.
Warning windows
Warning window "WARNING 1"
This window appears when configuration parameters are validated.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
It prompts the operator to switch the CPU board off and then on again, by using the changeover switch
SW1 or S9; this operation switches the power supply feeding the CPU board off and on in order to
reset the transmitter with its new configuration.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
53 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.3.2.
Warning window "WARNING 2"
It appears when the changeover switch SW1 or S9 is switched so that the dot is visible and that CPU
board is reset.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
This window appears after pressing "REINIT VALUES" in the "INSTALLATION PARAMETERS
Level 1" window.
CONTROL KEYS
FUNCTIONS
SELECTIONS AVAILABLE/COMMENTS
Validates the window.
After pressing this control keys, the CPU
board is set to the default configuration.
The "REINIT VALUES" control keys may be
used for a new installation procedure.
Cancels the window.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
54 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.3.3.
Warning window "Software UPDATE"
This window is called up by three following conditions:
♦ Inserting PCMCIA card in flash card drive. This card contains the new CPU software.
♦ Transmitter must be in installation mode changeover “SW1” or S9 is on position “visible dot”.
Press the « RESET » button of CPU board or Power off CPU board, opening the appropriate breakers.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
This window displays the download progress of the new CPU software. It is only available with TH860
CPU BOARD.
MESSAGE
FUNCTIONS
SELECTIONS AVAILABLE/COMMENTS
Give the window name
Display the down load operating
mode.
PLEASE WAIT.
CHECKING SOFTWARE VERSION
ERASING FLASH MEMORY
PROGRAMMING FLASH MEMORY
DONE, PLEASE WAIT.
Displays
progress.
the
45321648.01
Numéro / Number
down
load
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
55 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.3.4.
Warning window "WARNING 3"
This window appears when the CPU board start up, the communication between the CPU and tactile
screen is not still ready.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
It prompts the operator to wait a moment.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
56 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.4.
"TRANSMITTER STATUS" window
This window appears when the transmitter is switched on and the changeover switch SW1 or S9,
behind the CPU board, is switched so that the dot is not visible.
It can also be called up by pressing the "STATUS" control keys on the other windows.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
OPTIMUM FAMILY OR ULTIMATE FAMILY
Figure 6 : Dual Drive Transmitter
Figure 7 : Single Drive Transmitter
AFFINTY FAMILY
Figure 8 : Dual Drive Transmitter
45321648.01
Numéro / Number
Figure 9 : Single Drive Transmitter
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
57 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
CONTROL KEYS
FUNCTIONS
DISPLAY/COMMENTS
Calls up the "REQUIRED POWER" window ♦
(Reduction power). (3)
ATSC
transmitter
transmitter
OR
ANALOG
This control keys is available in Maintenance
mode only.
Control key invisible in Normal mode only.
♦
DVB-T transmitters
This control keys is available in Maintenance
mode and MFN mode operation only.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Control key invisible in Normal mode or SFN
mode operation.
Calls up the "GO HOME AND VIEW
INSTALLATION PARAMETERS" window.
Also displays the window title.
Calls up the "STATUS" window.
Calls up the "CONTROL Level 1" window.
Calls up the "EXCITER Level 1" window.
Calls up the "AMPLIFIERS" window. (a)
Calls up the "INTLOCK" window. (a)
Calls up the "POWER SUPPLY" window. (a)
Calls up the "AFFINITY" window. (b)
(a): Not Visible for AFFINITY family
(b): Not Visible for OPTIMUM or ULTIMATE families
(3): Unavailable for MedaFLO modulator
MESSAGE
FUNCTIONS
DISPLAY/COMMENTS
Gives the window name.
Displays the current operating mode of the
transmitter (maintenance mode or normal
mode).
MAINT MODE / NORMAL MODE
Displays the current remote control mode of
the transmitter.
SERIAL / PARALLEL
Blinking message to indicate
maintenance mode is operating
SERIAL : Remote control
RS432/485 serial link.
that
through
the
(Remote
controls
and
PARALLEL
indicators): Remote control through hard
wired connections.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
58 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
MESSAGE
FUNCTIONS
DISPLAY/COMMENTS
Indicates a higher value than the high alarm
threshold value.
Flashes if the transmitted power exceeds the
maximum power threshold value.
Otherwise not visible.
The alarm threshold is set using the «RF
THRESHOLD» window.
Displays the transmitted RF power value
This value is expressed in watts or as a
percentage of the calibrated power value
according with your installation choice
Indicates a lower value than the low alarm
threshold value.
Flashes if the transmitted power is lower
than the minimum power threshold value.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Otherwise not visible.
The alarm threshold is set using the «RF
THRESHOLD» window.
Indicates a higher value than the threshold
value.
Flashes if the reflected power (reverse
power) exceeds 3% of calibrated power
Otherwise not visible.
The threshold value (3%) is unchanging
Displays the reflected power value
This value is expressed in watts or as a
percentage of calibrated power value
according with your installation choice
To indicate the reflected (reserve) power
control mode.
FOLDBACK ENABLED: When the reflected
power value is higher than the threshold
value (3%) the power control is progressively
produce through an algorithm.
FOLDBACK DISABLED: When the reflected
power value is higher than the threshold
value (3%) the power control is produce by
stairway (-3dB, -6dB and halt ‘no power”)
Indicates the exciter selected.(*)
45321648.01
Numéro / Number
108
Doc.
EXC A / EXC B
9932 V2
Checked
Rev.
Langu.
27/06/2006
59 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
MESSAGE
FUNCTIONS
DISPLAY/COMMENTS
To indicate the exciter changeover mode
(Upper indicator).
To indicate the exciter changeover status in
automatic mode (Lower indicator).(*)
Upper indicator
CH-OVER MAN (Manual) :
operator gives a command.
only when
CH-OVER AUTO : automatic changeover
when the selected exciter is faulty.
Lower indicator
CH OVER DONE / CH OVER NOT DONE /
CH OVER IMPOSSIBLE
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
: the changeover system is
ready for an automatic switch over.
: the changeover system is
no longer available and it is necessary to
change the exciter selected or to carry out a
transmitter "RESET" (in this latter case, care
must be taken because fault data for all
faults which have disappeared will be erased
together with their consequences; similarly
for all selections carried out on the PCL).
: an attempt to carry out an
automatic changeover has failed.
(*) : Only in Dual Drive Version
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
60 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.5.
"STATUS" window
This window is called up by pressing the "NEXT STATUS" control keys in the "TRANSMITTER
STATUS" window.
It provides access to commands and information which are only available in the "STATUS" window.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
OPTIMUM FAMILY OR ULTIMATE FAMILY
Figure 10 : PCL UNLOCKED (ENABLED)
Figure 11 : PCL LOCKED
AFFINTY FAMILY
Figure 12 : PCL UNLOCKED (ENABLED)
CONTROL KEYS
Figure 13 : PCL LOCKED
FUNCTIONS
DISPLAY/COMMENTS
Calls up the "GO HOME AND VIEW
INSTALLATION PARAMETERS" window.
Locks (disables) the local control panel (P).
LOCK CMD / CMD LOCKED
Displays whether the CMD is locked or
unlocked.
When the CMD is locked, operator
commands from the PCL have no effect on
the system.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
61 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
CONTROL KEYS
FUNCTIONS
DISPLAY/COMMENTS
Calls up the "NUMERICAL VALUE" window
or the "IDENTIFICATION" window.
PASS / IDENT
IDENT : The "IDENTIFICATION" window
displays software references for the screen
and CPU card ; this function is available
when the touch screen is unlocked.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
UNLOCK : Operation is realized in
accordance with your installation choice
(PASSWORD DISABLE, or ENABLE)
♦
Pressing this control Key, the PCL is
automatically unlocked or,
♦
A password can be entered using the
"NUMERICAL VALUE" window while the
PCL is unlocked.
Calls up the "CONTOL Level 1" window.
Calls up the "EXCITER Level 1" window.
Calls up the "AMPLIFIERS" window. . (a)
Calls up the "INTLOCK" window. . (a)
Calls up the "POWER SUPPLY" window. (a)
Calls up the "AFFINITY" window. (b)
Calls up the "TRANSMITTER STATUS"
window.
(a): Not Visible for AFFINITY family
(b): Not Visible for OPTIMUM or ULTIMATE families
MESSAGE
FUNCTIONS
DISPLAY/COMMENTS
Gives the window name.
Last indicated faults.
This window displays the last three faults
which have been indicated.
Displays the current operating mode of
the transmitter (maintenance mode or
normal mode).
MAINT MODE / NORMAL MODE
45321648.01
Numéro / Number
108
Doc.
Blinking message to indicate that the
maintenance mode is operating
9932 V2
Checked
Rev.
Langu.
27/06/2006
62 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.6.
"IDENTIFICATION" window
This window is called up by pressing the "IDENT" control keys in the "STATUS" window. This window
is only accessible when the touch screen is unlocked with the “LOCK CMD / CMD LOCKED” control
keys in the “STATUS” window.
It displays software references for the touch screens, the CPU card and EXCITER units.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
OPTIMUM FAMILY OR ULTIMATE FAMILY
CONTROL KEYS
AFFINTY FAMILY
FUNCTIONS
DISPLAY/COMMENTS
Calls up the "MODULATOR IDENTIFICATION" window.
Calls up the "STATUS" window.
Calls up the "CONTROL Level 1" window.
Calls up the "EXCITER Level 1" window.
Calls up the "AMPLIFIERS" window. . (a)
Calls up the «INTERLOCK» window . (a)
Calls up the "POWER SUPPLY" window. . (a)
Calls up the "AFFINITY" window. (b)
(a): Not Visible for AFFINITY family
(b): Not Visible for OPTIMUM or ULTIMATE families
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
63 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
INDICATOR LAMPS AND
MESSAGE DISPLAYS
FUNCTIONS
DISPLAY/COMMENTS
Gives the window name.
Displays the reference of the CPU board software.
Displays the reference of the CPU board. PROM
software
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Displays the reference of the touch screen and its
software.
Displays the reference of the Main software for exciter A.
♦
Digital Transmitter, MODAP
Version only:
With oldest DAP software this
message displays could be
absent
Displays the reference of the Main software for exciter B. ♦ Analogue Transmitter
(*)
With the analogue driver, this
message displays is not used
(*) : Only in Double Drive Version
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
64 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.7.
"MODULATOR IDENTIFICATION, Type I" window
This window is called up by pressing the "IDENT NEXT" control keys in the "IDENTIFICATION"
window. It is only accessible when the touch screen is unlocked with the “LOCK CMD / CMD
LOCKED” control keys in the “STATUS” window.
This window displays software references for the MODULATOR unit. It is only available with
TANGBERG MODULATOR unit (MODAP version only).
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
OPTIMUM FAMILY OR ULTIMATE FAMILY
CONTROL KEYS
AFFINTY FAMILY
FUNCTIONS
DISPLAY/COMMENTS
Calls up the "IDENTIFICATION" window.
Calls up the "STATUS" window.
Calls up the "CONTROL Level 1" window.
Calls up the "EXCITER Level 1" window.
Calls up the "AMPLIFIERS" window. (a)
Calls up the «INTERLOCK» window (a)
Calls up the "POWER SUPPLY" window. (a)
Calls up the "AFFINITY" window. (b)
(a): Not Visible for AFFINITY family
(b): Not Visible for OPTIMUM or ULTIMATE families
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
65 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
INDICATOR LAMPS AND
MESSAGE DISPLAYS
FUNCTIONS
DISPLAY/COMMENTS
Calls up data from the other exciter. (*)
Gives the window name.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Displays the ID number of the module.
Displays the reference
MODULATOR software.
of
the
Internal
COFDM
Displays the reference
MODULATOR hardware.
of
the
internal
COFDM
Displays the reference
MODULATOR firmware.
of
the
internal
COFDM
Indicates which exciter data are displayed. (*)
EXC A / EXC B
(*) : Only in Double Drive Version
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
66 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.8.
"MODULATOR IDENTIFICATION, type II" window
This window is called up by pressing the "IDENT NEXT" control keys in the "IDENTIFICATION"
window. It is only accessible when the touch screen is unlocked with the “LOCK CMD / CMD
LOCKED” control keys in the “STATUS” window.
This window displays software references for the type II MODULATOR unit or for the SIRIUS
MODULATOR unit.
It is only available with type II MODULATOR unit “ACBB” (MODAP version) or with SIRIUS
MODULATOR unit.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
OPTIMUM FAMILY OR ULTIMATE FAMILY
CONTROL KEYS
AFFINTY FAMILY
FUNCTIONS
DISPLAY/COMMENTS
Calls up the "IDENTIFICATION" window.
Calls up the "STATUS" window.
Calls up the "CONTROL Level 1" window.
Calls up the "EXCITER Level 1" window.
Calls up the "AMPLIFIERS" window. (a)
Calls up the «INTERLOCK» window . (a)
Calls up the "POWER SUPPLY" window. (a)
Calls up the "AFFINITY" window. (b)
(a): Not Visible for AFFINITY family
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
67 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
(b): Not Visible for OPTIMUM or ULTIMATE families
. (a)
INDICATOR LAMPS AND
MESSAGE DISPLAYS
FUNCTIONS
DISPLAY/COMMENTS
Calls up data from the other exciter. (*)
Gives the window name.
Displays the reference of the internal COFDM ACBB
MODULATOR software.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Displays the reference of the Boot software.
Displays the reference of the LINUX software.
Displays the reference of the FPGA 1software.
Displays the reference of the FPGA 2 software.
Indicates which exciter data are displayed. (*)
EXC A / EXC B
(*) : Only in Double Drive Version
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
68 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.9.
"CONTROL Level 1" window
From other windows it can be called up by pressing the "CONTROL" key.
This window contains the commands available in maintenance mode and normal mode.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
OPTIMUM FAMILY OR ULTIMATE FAMILY – ANALOG TRANSMITTER
Figure 14: Dual Drive Transmitter
Figure 15: Single Drive Transmitter
OPTIMUM FAMILY OR ULTIMATE FAMILY – DIGITAL TRANSMITTER
Figure 16: Dual Drive Transmitter
Figure 17: Single Drive Transmitter
AFFINTY FAMILY – DIGITAL TRANSMITTER
Figure 18: Dual Drive Transmitter
45321648.01
Numéro / Number
Figure 19: Single Drive Transmitter
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
69 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
CONTROL KEYS
FUNCTIONS
DISPLAY/COMMENTS
Selects local or remote user interface.
The command is not available if the PCL is
locked. Selecting remote user interface locks
the following control keyss: CTRL, STDBY,
MODE, EXCITER
Initiates shutdown or start-up of the reserve
exciter.
Command is disabled while the PCL is
locked (disabled).
Selects the transmitter on-air/off-air switching
mode (manual or automatic)
Command is disabled while the PCL is
locked (disabled)
Selects the transmitter-operating
(maintenance or normal).
Command is disabled while the PCL is
locked (disabled).
Only in Double Drive Version
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Only in Analogue Transmitter
mode
Validates a selection.
Cancels a selection.
Calls up the "TRANSMITTER STATUS"
window.
Calls up windows as follows:
"CONTROL MAINT Level 2", if the system is
in maintenance mode,
"CONTROL OPER Level 2", if the system is
in normal mode.
Calls up the "EXCITER Level 1" window.
Calls up the "AMPLIFIERS" window. (a)
Calls up the "INTLOCK" window. (a)
Calls up the "POWER SUPPLY" window. (a)
Calls up the "AFFINITY" window. (b)
(a): Not Visible for AFFINITY family
(b): Not Visible for OPTIMUM or ULTIMATE families
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
70 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
MESSAGE
FUNCTIONS
DISPLAY/COMMENTS
Displays the current remote control mode of
the transmitter.
SERIAL / PARALL
SERIAL : Remote control
RS432/485 serial link.
through
PARALL (Remote controls and indicators):
Remote control through hard wired
connections.
Displays the selected user interface.
REMOTE / LOCAL
REMOTE : Indicates a remote user interface.
LOCAL : Indicates Local Control Panel.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Only commands from the selected user
interface will be operative.
Flashes until the "CTRL" command is either
validated or cleared.
Displays the status (on or off) of the reserve
exciter.
OFF / ON
Displays the on-air/off-air switching mode
selected
MANUAL, AUTO
Displays the current operating mode of the
transmitter (maintenance mode or normal
mode).
NORMAL / MAINT
Only in Double Drive Version
Only in Analogue Transmitter
45321648.01
Numéro / Number
108
Doc.
Flashes until the "STDBY" command is
either validated or cleared.
Flashes until the «START» command is
either validated or cleared
Flashes until the "MODE" command is either
validated or cleared.
9932 V2
Checked
Rev.
Langu.
27/06/2006
71 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.10. "CONTROL MAINT Level 2" window for Maintenance mode
This window is called up by pressing the "NEXT CONTROL" control keys in the "CONTROL Level 1"
window while the transmitter is in maintenance mode.
It provides access to commands and information which are only available in maintenance mode.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
OPTIMUM FAMILY OR ULTIMATE FAMILY
CONTROL KEYS
AFFINTY FAMILY
FUNCTIONS
DISPLAY/COMMENTS
Calls up the "MODIFY PASSWORD" window
(for changing the password).
This control key is available according to
your installation choice (PASSWORD
DISABLE, ENABLE)
Control
key
visible
in
« PASSWORD ENABLE » only.
selection
Calls up the "RF LEVEL" window.
Calls up the "HOUR COUNTER" window.
Calls up the "DATE & TIME" window.
Calls up the "RF THRESHOLD" window.
Calls up the "QUALITY
SETTINGS" window.
THRESHOLD
Calls up the "MODULATOR PARAMETERS"
window.
Calls up the "MISCELLANEOUS" window.
Calls up the "DVB-H MODULATOR
PARAMETERS" window.. (1)
45321648.01
Numéro / Number
108
Doc.
The control key is according to your
installation mode
9932 V2
Checked
Rev.
Langu.
27/06/2006
72 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
CONTROL KEYS
FUNCTIONS
DISPLAY/COMMENTS
Calls up the "LOGBOOK" window.
Calls up the "TRANSMITTER STATUS"
window.
Calls up the "CONTROL MAINT Level 3"
window.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Calls up the "EXCITER Level 1" window.
Calls up the "AMPLIFIERS" window. (a)
Calls up the «INTERLOCK» window (a)
Calls up the "POWER SUPPLY" window. (a)
Calls up the "AFFINITY" window. (b)
(a): Not Visible for AFFINITY family
(b): Not Visible for OPTIMUM or ULTIMATE families
(1): Visible for DVB-H transmitter only
MESSAGE
FUNCTIONS
DISPLAY/COMMENTS
Displays the current operating mode of the
transmitter (maintenance mode or normal
mode).
The "MAINT MODE" message window must
be displayed.
Blinking message to indicate
maintenance mode is operating
Displays, which gain control mode (manual
or automatic), is currently picked up by the
transmitter.
45321648.01
Numéro / Number
108
Doc.
that
MANUAL GAIN / AUTO GAIN
9932 V2
Checked
Rev.
Langu.
27/06/2006
73 / 192
Page
the
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.11. "CONTROL MAINT Level 3" window for Maintenance mode
This window is called up by pressing the "NEXT CONTROL" control keys in the "CONTROL MAINT
Level 2" window while the transmitter is in maintenance mode.
It provides access to commands and information which are only available in maintenance mode.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
OPTIMUM FAMILY OR ULTIMATE FAMILY
CONTROL KEYS
AFFINTY FAMILY
FUNCTIONS
DISPLAY/COMMENTS
Selects the RF synthesiser alarm mode.
Toggles between 10 MHz INT and 10MHz
EXT
Increments or decrements RF synthesiser
frequency value.
Flashes until the "SYNTHE" command is
either validated or cleared.
Commands are disabled while the PCL is
locked (disabled).
Control keys are only invisible in SFN mode
operation.
Validates a selection.
Cancels a selection.
Calls up the "NUMERICAL VALUE" window
in which the shoulder threshold beyond
which the exciter performs a correction can
be changed.
Displays last selection.
Calls up the “NUMERICAL VALUE” window
in which the ripple threshold beyond which
the exciter performs a correction can be
changed.
Displays last selection.
Calls up the “NUMERICAL VALUE” window
in which the group delay threshold beyond
which the exciter performs a correction can
be changed. (3)
Displays last selection.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
74 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
CONTROL KEYS
FUNCTIONS
DISPLAY/COMMENTS
Calls up the "TRANSMITTER STATUS"
window.
Calls up the "CONTROL Level 4" window.
Calls up the "EXCITER Level 1" window.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Calls up the "AMPLIFIERS" window. (a)
Calls up the «INTERLOCK» window (a)
Calls up the "POWER SUPPLY" window. (a)
Calls up the "AFFINITY" window. (b)
(a): Not Visible for AFFINITY family
(b): Not Visible for OPTIMUM or ULTIMATE families
(3): MediaFLO modulator only
MESSAGE
FUNCTIONS
DISPLAY/COMMENTS
Displays the current operating mode of the
transmitter (maintenance mode or normal
mode).
The "MORMAL MODE" message window
must be displayed.
Displays the RF synthesiser alarm mode.
10 MHz INT, 10 MHz EXT
Blinking message to indicate
maintenance mode is operating
that
Displays the RF synthesiser frequency value.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
75 / 192
Page
the
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
2.1.12. "CONTROL MAINT Level 4" window for Maintenance mode (MODAP version
ONLY)
This window is called up by pressing the "CONTROL NEXT" control keys in the "CONTROL MAINT
Level 3" window while the transmitter is in maintenance mode.
It provides access to commands and information which are only available in maintenance mode.
NOTE: This windows is available in COFDM MODAP version only.
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
OPTIMUM FAMILY OR ULTIMATE FAMILY
CONTROL KEYS
AFFINTY FAMILY
FUNCTIONS
DISPLAY/COMMENTS
Selects the type of correction performed by
the OLDC card (Fixed or Adaptive).
Command is disabled while the PCL is
locked (disabled).
In fixed position, the OLDC correction
parameters are not continuously adjusted.
Cancels a selection.
Validates a selection.
Calls up the "NUMERICAL VALUE" window
in which the I/Q amplitude error threshold
beyond which the OLDC card performs a
correction can be changed.
Command is disabled while the PCL is
locked (disabled).
Displays last selection.
Calls up the "NUMERICAL VALUE" window
in which the central frequency rejection
threshold beyond which the OLDC card
performs a correction can be changed.
Command is disabled while the PCL is
locked (disabled).
Displays last selection.
Calls up the "TRANSMITTER STATUS"
window.
Calls up the "CONTROL Level 1" window.
45321648.01
Numéro / Number
108
Doc.
9932 V2
Checked
Rev.
Langu.
27/06/2006
76 / 192
Page
Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
CONTROL KEYS
FUNCTIONS
DISPLAY/COMMENTS
Calls up the "EXCITER Level 1" window.
Calls up the "AMPLIFIERS" window. (a)
Calls up the «INTERLOCK» window (a)
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
Calls up the "POWER SUPPLY" window. (a)
Calls up the "AFFINITY" window. (b)
(a): Not Visible for AFFINITY family
(b): Not Visible for OPTIMUM or ULTIMATE families
MESSAGE
FUNCTIONS
DISPLAY/COMMENTS
Displays whether a Double ASI input is
present or absent in the MODAP unit.
DASI NOT FITTED / DASI FITTED
Displays whether an OLDC unit is present or
absent.
OLDC FITTED / OLDC NOT FITTED
Displays the type of correction (fixed or
adaptive) performed by the OLDC unit.
ADAPTIVE / FIXED
Displays last selection.
Displays the current operating mode of the
transmitter (maintenance mode or normal
mode).
45321648.01
Numéro / Number
108
Doc.
In fixed position, the OLDC correction
parameters are not continuously adjusted.
The "MAINT MODE" message window must
be displayed.
Blinking message to indicate
maintenance mode is operating
9932 V2
Checked
Rev.
Langu.
27/06/2006
that
77 / 192
Page
the

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 39
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:9c7e1236-75cf-475f-bf74-3a7b018cb870
Modify Date                     : 2006:07:07 13:20:21-04:00
Create Date                     : 2006:07:07 13:20:07-04:00
Metadata Date                   : 2006:07:07 13:20:21-04:00
Document ID                     : uuid:868ea05e-1051-43bf-ba51-ed12578332a4
Format                          : application/pdf
Tagged PDF                      : Yes
Title                           : PREIMPAP.DOC
Creator                         : Acrobat PDFMaker 6.0 pour Word
Author                          : TBM
Subject                         : Instructions de formatage du modle PREIMPAP.DOT
Producer                        : Acrobat Distiller 6.0 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CHPULT-1K10K2

Navigation menu