Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-1 IF Processor Module LO/Upconverter Module Chapter 2 System Description & Remote Control Connections  The Innovator LX Series of drivers/translators are complete 10W to 100W analog UHF translators that operate at nominal visual output power of 10 to 100 watts peak sync and an aural output power of 1 to 10 watts at an A/V ratio of 10dB, 10% sound or .5 to 5 watts at 13 dB, 5% sound.   2.1 System Overview  The Innovator LX Series translator is made up of a Receiver Tray and an exciter amplifier chassis assembly.  The modules and assemblies that make up the translator are listed in Table 2-1.   Table 2-1: Innovator LX Series Translator Trays and Assemblies                  ASSEMBLY DESIGNATOR  TRAY/ASSEMBLY NAME  PART NUMBER  Receiver Tray  1265-1100 A3  IF Processor Module  1301938 A4  Control & Monitoring/Power Supply Module 1301936 A5 LO/Upconverter Module 1301930 A6  Power Amplifier Module, 100 Watt Translator  1301923 A11 Backplane Board 1301941 A12 Switch Board  1527-1406 A20  LCD Display Board          Receiver Tray Controller/ Power Supply Module Power Amplifier Module
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-2 2.1.1 8 Receiver Tray (1265-1100; Appendix B)         The Receiver Tray receives a VHF or UHF Channel input at Jack (J1) and converts it to an internally diplexed Visual + Aural IF Output (+0 dBm) at J4.  The Visual + Aural IF output of the Receiver Tray at J4 is fed to J6 the IF Input Jack of the exciter.         Table 2-5. Receiver Samples  SAMPLE DESCRIPTION Front panel sample – f (IF)  Sample of the IF output Front panel sample – f (s)   Sample of the channel oscillator  Exciter Amplifier Chassis Assembly  All of the modules except the power amplifier module and the power supply section, located in the Control & Monitoring/Power Supply Module, plug directly into a backplane board, which provides module to module interconnection as well as interconnection to remote command and control connectors.   RECEIVER TRAY  INPUT LEVEL: -61 dBm to –16dBm OUTPUT LEVEL: 0 dBm POWER REQUIREMENTS: 110 or 220 VAC
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-3 2.1.2 (A3) IF Processor Module Assembly (1301938; Appendix B)   The (A3) IF Processor Assembly contains the IF Processor Board (1301977). The IF Processor provides pre-correction to ensure broadcast quality output signal. The pre-correction consists of amplitude linearity correction, Incidental Carrier Phase Modulation (ICPM) correction and frequency response correction.  The IF Processor module is configured either for an analog or digital system.  Pin 13C of the IF Processor module is grounded in analog systems and left not connected in digital systems.  An IF Processor Interlock signal is used to report the presence of the IF Processor module to the Control Monitoring board.  If the IF Processor interlock signal is not present, the Innovator LX 100 Watt Translator/Exciter Driver RF output is Muted (turned off).  If an analog IF Processor module is installed and the Modulation Present signal is not true, the Innovator LX 100 Watt Translator / Exciter Driver output is Muted (turned off).  The Control & Monitoring/Power Supply module uses the IF Processor module for System output power control.  Through the front panel display or a remote interface, an operator can set the translator's RF output power.  The range of RF power adjustment is between 0% (full off) and 105% (full power plus).  A front panel IF Processor module potentiometer sets the upper limit of RF power at 120%.  The system's Control Monitoring board compares the RF Power Monitoring module RF power level with the desired level and uses the IF Power Control PWM line to correct for errors.   In digital systems, a digital level control (DLC) voltage is generated on the IF Processor module and sent to an external digital modulator (DT1C or DT2B).  RF power control is implemented by changing the DLC voltage provided to the external digital modulator.  The 'RF High' potentiometer sets the upper adjusted range of RF control circuit output to 120%.   The IF Processor module provides a reference ALC voltage to the system's Upconverter.  When the ALC voltage decreases, the Upconverter automatically lowers the system output power through the AGC circuits.  The IF Processor module has a front panel switch to select Auto or Manual ALC.  When Manual ALC is selected, the reference ALC voltage is set by a front panel potentiometer.  In this condition, the RF power level control circuit is removed from use.  When the ALC select switch is changed to Auto, the RF power level control circuit will start at low power and increase the RF output until the desired output power is attained.  The IF Processor module Modulation Present signal is monitored.  If the modulation level is too low or non-existent, a Modulation Present fault is reported to the Control Monitoring board.  When the controller detects this fault, it can be set to Automatically Mute the translator or in Manual mode the translator will continue to operate at 25% output.   The IF Processor module Input Signal level is monitored.  If the signal level is too low or non-existent, an Input fault is
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-4 reported on the Control Monitoring board.  When the IF Processor board detects an Input Signal fault it automatically Mutes the translator.  The system controller does not Mute on an IF Processor Input fault.  Table 2-6. IF Processor Front Panel Switch  SWITCH FUNCTION MAN/AUTO ALC When Manual ALC is selected, the reference ALC voltage is set by the ALC Gain front panel potentiometer.   When Auto ALC is selected, the IF level control circuit will automatically increase the IF output until the desired output power is attained.   Table 2-7. IF Processor Front Panel Status Indicators  LED FUNCTION INPUT FAULT (Red)  When lit it indicates that there is a loss of the IF Input signal to the IF Processor.  Translator can be set to Mute on an IF Input Fault. ALC Fault (Red) When lit it indicates that the required gain to produce the desired output power level has exceeded the operational range of the ALC circuit.  The LED will also be lit when ALC is in Manual. MUTE (Red)  When lit it indicates that the IF input signal is cut back but the enable to the Power Supply is present and the +32 VDC remains on.  Table 2-8. IF Processor Front Panel Control Adjustments  POTENTIOMETERS DESCRIPTION FREQUENCY RESPONSE EQUALIZER These three variable resistors, R103, R106 & R274, adjust the depth of gain for the three stages of frequency response correction. ALC GAIN  Adjusts the gain of the translator when the translator is in the Auto ALC position. MAN GAIN  Adjusts the gain of the translator when the translator is in the Manual ALC position. LINEARITY CORRECTION These three variable resistors adjust the threshold cut in for the three stages of linearity pre-correction.  R211 and R216, the top two pots, are adjusted to correct for in phase amplitude distortions.  R 231, the bottom pot, is adjusted to correct for quadrature phase distortions.  Table 2-9. IF Processor Front Panel Sample  SMA CONNECTOR  DESCRIPTION IF SAMPLE  Sample of the pre-corrected IF output of the IF Processor
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-5  2.1.3 (A5) LO/Upconverter Module Assembly, Digital  (1301954; Appendix B)     The (A5) LO/Upconverter Module Assembly contains a front panel LED display board (1303033), a UHF Filter (1007-1101), a UHF Generator Board (1585-1265) and a LO/Upconverter Assembly (1303039). The LO/Upconverter Assembly contains the LO/Upconverter Board (1302132).  The Innovator LX Upconverter converts an IF input signal to a RF output signal on the desired channel frequency using a high stability oven controlled oscillator with very low phase noise and an Automatic Level Control (ALC) for stable output signal level.  Several control voltages are used for translator power control.  Automatic gain control (AGC) circuits set the RF output level of the translator system.   AGC #1 is provided by the 50 Watt Translator/Exciter Driver Power Amplifier module.  This voltage is used by the Upconverter to maintain a constant RF output level at the Power Amplifier module output.  If this voltage exceeds 0.9 VDC, the system is in an over-drive condition.  The 0.9 VDC over-driver threshold is set by a front panel Upconverter module potentiometer.  When an over-drive condition is detected, the Upconverter module reduces its RF output level.  For values less than 0.9 VDC, the Upconverter uses the AGC #1 voltage for automatic gain control by setting it's RF output to maintain AGC #1 equal to the AGC voltage set by another front panel potentiometer.  When the Upconverter is set for manual gain, the RF output of the Upconverter is set by the front panel AGC potentiometer.  In manual gain operation, the AGC #1 feedback voltage from the PA is not used to adjust the RF level unless an over-drive condition is detected.  AGC #2 is provided by each of the optional external amplifier modules.  Diodes are used in each of the external amplifier forward power circuits to capture the highest detected sample voltage.  This voltage is used by the Upconverter to maintain a constant RF output of the system.  As with AGC #1, the Upconverter module reduces its RF output level if AGC #2 is too high.  AGC #1 and ACG #2 are diode ORed together in the Upconverter gain circuit.  Both AGC voltages are first reduced by an on-board potentiometer before being amplified.  If an over-drive condition does not exist, the higher of the two AGC voltages is used to control the Upconverter gain circuit.  An AFC Voltage is generated to control the VCXO of the UHF Generator portion of the Upconverter module.  The typical AFC voltage is 1.5 VDC but it can be as high as +5 VDC.  The Upconverter can operate on either it's internal 10 MHz source or on a 10 MHz external reference signal.  When an external 10 MHz source is present on J10, it is automatically selected.  An external reference present signal is provided to the controller for display purposes.  The selected 10 MHz signal from the Upconverter is buffered then sent to the backplane on two ports.  One
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-6 port is sent to the Modulator module, if present, and the other is routed to a BNC connector (J11) on the backplane for a system 10 MHz output signal.  A National Semiconductor frequency synthesizer IC is used in the frequency conversion of the IF signal to a RF signal.  The frequency synthesizer IC uses a 10MHz reference frequency for signal conversion.  Typically the IF input frequency is 45.75 MHz for analog system and 44 MHz for DTV.  To obtain different output RF frequencies, the synthesizer IC is serial programmed by the Control Monitoring board.  The part is programmed to use a 5 kHz phase detection frequency.  With a 10 MHz input signal, the R counter is set to 2000. With these settings the N counter is set to the desired LO frequency in kHz / 5 kHz.  The maximum LO frequency setting with these parameters is 1310.715 MHz.  Example:  For a Frequency RF Out = 517.125 MHz, N = 517125 kHz / 5 kHz = 103425  An Upconverter PLL Lock indicator is used to insure that the frequency control circuits are operating properly.  When the Upconverter PLL is locked, the frequency synthesizer IC is programmed and the Power Amplifier module(s) can be enabled.  The RF output of the LO/Upconverter Module is at J23 on the rear chassis.   Table 2-10. LO/Upconverter Front Panel Switch  SWITCH FUNCTION MAN/AUTO AGC When Manual AGC is selected, the reference AGC voltage is set by the AGC Manual Gain front panel potentiometer.   When Auto AGC is selected, the RF power level control circuit will automatically increase the RF output until the desired output power is attained.  Table 2-11. LO/Upconverter Front Panel Status Indicator  LED FUNCTION AGC CUTBACK (Red) When lit it indicates that the required gain to produce the desired output power level has exceeded the level set by the AGC Cutback (Override) adjust.  Translator will cut back power to 25%  Table 2-12. LO/Upconverter Front Panel Control Adjustments  POTENTIOMETERS DESCRIPTION MAN GAIN ADJ  Adjusts the gain of the translator when the translator is in the Manual AGC position. AGC CUTBACK ADJ (AGC OVERRIDE) Adjusts the point at which the translator will cut back in power when the Translator is in the Auto AGC position.  Table 2-13. LO/Upconverter Front Panel Samples  SMA CONNECTOR  DESCRIPTION LO SAMPLE  Sample of the LO signal to the Upconverter as generated by the UHF Generator Board. RF SAMPLE  Sample of the On Channel RF Output of the Upconverter
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-7  2.1.4 (A4) Control & Monitoring/ Power Supply Module Assembly (1301936; Appendix B)    8 A4 A The (A4) Control & Monitoring/Power Supply Assembly is made up of a Control Board (1302021), a Power Protection Board (1302837) and a Switch Board (1527-1406).  The Assembly also contains a switching power supply that provides ±12 VDC to the rest of the modules in the chassis and +32 VDC to the Power Amplifier module.  The Assembly provides all translator control and monitoring functions.  The Front panel LCD allows monitoring of system parameters, including forward and reflected power, transistor currents, module temperatures and power supply voltages.  Table 2-14. Controller/Power Supply Display  DISPLAY FUNCTION LCD A 4 x 20 display providing a four-line readout of the internal functions, external inputs, and status. See Chapter 3, Controller/Power Supply Display Screens, for a listing of displays.  Table 2-15. Controller/Power Supply Status Indicator  LED FUNCTION OPERATE ( green ) When lit it indicates that the translator is in the Operate Mode.  If translator is Muted the Operate LED will stay lit, the translator will remain in Operate, until the input signal is returned. FAULT ( red or green ) Red indicates that a problem has occurred in the translator.  The translator will be Muted or placed in Standby until the problem is corrected. DC OK ( red or green ) Green indicates that the switchable fuse protected DC outputs that connect to the modules in the translator are OK.  Table 2-16. Controller/Power Supply Control Adjustments  POTENTIOMETERS DESCRIPTION DISPLAY CONTRAST  Adjusts the contrast of the display for desired viewing of screen.
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-8 2.1.5 (A6) Power Amplifier Module Assembly, Exciter, 5W-50W Translator (1301923; Appendix B)    The (A6) Power Amplifier Module Assembly is made up of a Coupler Board Assembly (1301949), an Amplifier Control Board (1301962), a 1 Watt Module Assembly (1302891), a TFS 40W UHF Module (1206693) and a RF Module Pallet, Philips (1300116).  The Power Amplifier Module contains Broadband LDMOS amplifiers that cover the entire UHF band with no tuning required. They amplify the RF to the 10W to 50W output power level of the translator.  The Power Amplifier of the Translator/Exciter Driver is used to amplify the RF output of the Upconverter module.  A cable, located on the rear chassis, connects the RF output from the LO/Upconverter at J23 to J24 the RF input to the PA Assembly.  This module contains RF monitoring circuitry for both an analog and a digital system.  Control and monitoring lines to the Power Amplifier module are routed through the floating blind-mate connector of the Control & Monitoring/Power Supply module.  The 50 Watt Translator/Exciter Driver Power Amplifier module and any External Amplifier modules contain the same control and monitoring board.  This board monitors RF output power, RF reflected power, the current draw of amplifier sections, the supply voltage, and the temperature of the PA heat sink.  The RF power detector circuit outputs vary with operating frequency.  These circuits must be calibrated at their intended operating frequency.  Front panel adjustment potentiometers are used to calibrate the following:  Table 1: Power Amplifier Calibration Adjustments in Analog Systems  R201  Reflected Power Cal R202  Visual / Forward Power Cal R203  Aural Power Cal R204  Visual Offset Zero R205 Aural Null  In analog systems, the Aural power of an Exciter Driver Power Amplifier and the Aural power of any external amplifier will not be reported by the system Control Monitoring module.  Additionally the Visual power of these amplifiers, is reported as Forward Power just like in digital systems.  In analog systems, aural and visual power will only be reported for the final system RF output.    In digital systems, the Forward power of an Exciter Driver Power Amplifier and the Forward power of any external amplifier, is reported by the system Control Monitoring module.   If the Control Monitoring module is monitoring a 5-50 Watt Translator, system power is measured in the Power Amplifier module.  The wired connections are transferred through the power supply connector to the backplane board on a five position header.  All four positions of control board switch SW1 must be set on to
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-9 route these lines as the system's RF power signals.  In systems of output power greater than 50 Watts, system power is monitored by an external module that is connected to TB31 and control board SW1 switches must be set off.   The Forward Power of the Translator/Exciter Driver Power Amplifier module is routed to the Upconverter module as AGC #1.  A system over-drive condition is detected when this value rises above 0.9 VDC.  When an over-drive condition is detected, the Upconverter module reduces its RF output level.  For values less than 0.9 VDC, the Upconverter uses this voltage for automatic gain.   Table 2-17. Power Amplifier Status Indicator  LED FUNCTION ENABLED (Green) When lit Green, it indicates that the PA is in the Operate Mode.  If a Mute occurs, the PA will remain Enabled, until the input signal is returned. DC OK (Green) When lit Green, it indicates that the fuse protected DC inputs to the PA module are OK. TEMP (GREEN) When lit Green, it indicates that the temperature of the heatsink assembly in the module is below 78˚C. MOD OK (Green) When lit Green, it indicates that the PA Module is operating and has no faults.  Table 2-18. Power Amplifier Control Adjustments  POTENTIOMETERS DESCRIPTION RFL CAL  Adjusts the gain of the Reflected Power monitoring circuit VISUAL CAL  Adjusts the gain of the Visual / Forward Power monitoring circuit AURAL CAL  Adjusts the gain of the Aural Power monitoring circuit VISUAL ZERO  Adjusts the offset of the Forward Power monitoring circuit AURAL NULL  Adjusts the offset of the Forward Power monitoring circuit based on the Aural signal level..  Table 2-19. Power Amplifier Sample  DISPLAY FUNCTION FWD SAMPLE  RF sample of the amplified signal being sent out the module on J25.  2.1.6 RF Output Assemblies  Modulated IF from the Receiver Tray connects to the rear of the Innovator LX chassis assembly at J6, Modulated IF Input.  The power amplifiers RF output jack is at a “N” connector J25, PA RF Output.   The RF output of the PA module is connected to a band-pass and trap filter and then to an output coupler assembly. The coupler assembly provides a forward and a reflected power sample for test purposes.  2.2 Control and Status  The control and status of the exciter/amplifier Chassis assembly is found by operating the front panel display screens.  Detailed information on the use of the screens is found in chapter 3.
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-10 2.2.1 Front Panel Display Screen  A 4 x 20 display located on the front of the Control & Monitoring/Power Supply Module is used in the Innovator LX translator for control of the operation and display of the operating parameters of the translator.    2.3 System Operation  When the translator is in operate, as set by the menu screen located on the Control & Monitoring Module.  The IF Processor will be enabled, the mute indicator on the front panel will be extinguished.  The +32 VDC stage of the Power Supply in the Control & Monitoring Module is enabled, the operate indicator on the front panel is lit and the DC OK on the front panel should also be green.  The enable and DC OK indicators on the PA Module will also be turned to green.  When the translator is in standby.  The IF Processor will be disabled, the mute indicator on the front panel will be red.  The +32 VDC stage of the Power Supply in the Control & Monitoring Module is disabled, the operate indicator on the front panel will be extinguished and the DC OK on the front panel should remain green.  The enable and indicator on the PA Module is also extinguished.  If the translator does not switch to Operate when the operate menu is switched to Operate, check that all faults are cleared and that the remote control terminal block stand-by signal is not active.   The translator can be controlled by the presence of the modulated input signal.  If the input signal to the translator is lost, the translator will automatically cutback and the input fault indicator on the IF Processor module will light. When the video input signal returns, the translator will automatically return to full power and the input fault indicator will be extinguished. 2.3.1 Principles of Operation  Operating Modes  This translator is either operating or in standby mode.  The sections below discuss the characteristics of each of these modes.  Operate Mode  Operate mode is the normal mode for the translator when it is providing RF power output.  To provide RF power to the output, the translator will not be in mute.  Mute is a special case of the operate mode where the power supply's +32 VDC section is enabled but there is no RF output power, because of a fault condition that causes the firmware to hold the IF Processor module in a mute state.   Operate Mode with Mute Condition  The translator will remain in operate mode but will be placed in mute when the following fault conditions exists in the translator.  • Upconverter is unlocked • Upconverter module is not present • IF Processor module is not present • Modulator (if present) is in Aural/Visual Mute  Entering Operate Mode  Entering the operate mode can be initiated a few different ways by the translator control board.  A list of the actions that cause the operate mode to be entered is given below:  • A low on the Remote Translator Operate line. • User selects "OPR" using switches and menus of the front panel.  • Receipt of an “Operate CMD” over the serial interface.
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-11 There are several fault or interlock conditions that may exist in the translator that will prevent the translator from entering the operate mode.  These conditions are:  • Power Amplifier heat sink temperature greater than 78˚C. • Translator is Muted due to conditions listed above. • Power Amplifier Interlock is high indicating that the amplifier is not installed.  Standby Mode  The standby mode in the translator indicates that the translator’s output amplifier is disabled.    Entering Standby Mode  Similar to the operate mode, the standby mode is entered various different ways.  These are:  • A low on the Remote Translator Stand-By line. • Depressing the “STB” key on selected front panel menus. • Receipt of a “Standby CMD” over the serial interface.  Operating Frequency  The Innovator LX translator controller is designed to operate on UHF and VHF frequencies.  The exact output frequency of the translator can be set to one of the standard UHF or VHF frequencies, or it can be set to a custom frequency using software set-up menus.  Since RF performance of the translator requires different hardware for different frequency bands, not all frequency configurations are valid for a specific translator.  Power detectors have frequency dependency, therefore detectors of power amplifiers are calibrated at their frequency of use.  The detectors for System RF monitoring are also calibrated at the desired frequency of use.  Table 2-22: VHF Television Frequencies BAND CH #  FREQUENCY  BAND CH #  FREQUENCY VHF LOW  02  54-60 MHz  VHF HIGH  07  174-180 MHz VHF LOW  03  60-66 MHz  VHF HIGH  08  180-186 MHz VHF LOW  04  66-72 MHz  VHF HIGH  09  186-192 MHz VHF LOW  05  76-82 MHz  VHF HIGH  10  192-198 MHz VHF LOW  06  82-88 MHz  VHF HIGH  11  198-204 MHz VHF HIGH  12  204-210 MHz  VHF HIGH  13  210-216 MHz Table 2.23: UHF Television Frequencies CH #  FREQUENCY CH #  FREQUENCY CH #  FREQUENCY 14  470-476 MHz  38  614-620 MHz  61  752-758 MHz 15  476-482 MHz  39  620-626 MHz  62  758-764 MHz 16  482-488 MHz  40  626-632 MHz  63  764-770 MHz 17  488-494 MHz  41  632-638 MHz  64  770-776 MHz 18  494-500 MHz  42  638-644 MHz  65  776-782 MHz 19  500-506 MHz  43  644-650 MHz  66  782-788 MHz 20  506-512 MHz  44  650-656 MHz  67  788-794 MHz 21  512-518 MHz  45  656-662 MHz  68  794-800 MHz 22  518-524 MHz  46  662-668 MHz  69  800-806 MHz 23  524-530 MHz  47  668-674 MHz  70  806-812 MHz
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-12 CH #  FREQUENCY CH #  FREQUENCY CH #  FREQUENCY 24  530-536 MHz  48  674-680 MHz  71  812-818 MHz 25  536-542 MHz  49  680-686 MHz  72  818-824 MHz 26  542-548 MHz  50  686-692 MHz  73  824-830 MHz 27  548-554 MHz  51  692-698 MHz  74  830-836 MHz 28  554-560 MHz  52  698-704 MHz  75  836-842 MHz 29  560-566 MHz  53  704-710 MHz  76  842-848 MHz 30  566-572 MHz  54  710-716 MHz  77  848-854 MHz 31  572-578 MHz  55  716-722 MHz  78  854-860 MHz 32  578-584 MHz  56  722-728 MHz  79  860-866 MHz 33  584-590 MHz  57  728-734 MHz  80  866-872 MHz 34  590-596 MHz  58  734-740 MHz  81  872-878 MHz 35  596-602 MHz  59  740-746 MHz  82  878-884 MHz 36  602-608 MHz  60  746-752 MHz  83  884-890 MHz 37 608-614 MHz     2.4 Customer Remote Connections  The remote monitoring and operation of the translator is provided through jacks TB30 and TB31 located on the rear of the chassis assembly. If remote connections are made to the translator, they must be made through plugs TB30 and TB31 at positions noted on the translator interconnect drawing and Table 2-25.
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-13 Table 2-25: Innovator LX Chassis Assembly Hard Wired Remote Interface Connections to TB30 or TB31, 18 pos. Terminal Blocks Located on the Rear of the Assembly  Signal Name  Pin Designations  Signal Type/Description RMT Translator State  TB30-1  Discrete Open Collector Output - A low indicates that the translator is in the operate mode. RMT Translator Interlock  TB30-2 Discrete Open Collector Output - A low indicated the translator is OK or completes a interlock daisy chain.  When the translator is not faulted, the interlock circuit is completed. RMT Translator Interlock Isolated Return TB30-3 Ground - Configurable ground return which can be either jumpered directly to ground or it can be the “source” pin of an FET so that the translator interlock can be daisy chained with other translators.  This signal does not directly interface to the microcontroller. RMT AUX IO 1  TB30-4 RMT AUX IO 2  TB30-5 Discrete Open Collector Inputs, Discrete Open Drain Outputs, or 0 - 5 VDC Analog Input - When used as an output, this line is pulled to +5 VDC with a 1.0 kΩ resistor for logic high and pulled to ground for a low.  A diode allows this line to be pulled up to 12 VDC.  When used as a digital input, this line considers all values over 2 Volts as high and those under 1 volt as low.  As an analog input, this line is protected by a 5.1 zener diode. RMT  Translator Operate  TB30-6 Discrete Open Collector Input - A pull down to ground on this line indicates that the translator is to be placed into the operate mode. RMT Translator Stand-By TB30-7 Discrete Open Collector Input - A pull down to ground on this line indicates that the translator is to be placed into the standby mode. RMT Power Raise  TB30-8 Discrete Open Collector Input - A pull down to ground on this line indicates that the translator power is to be raised. RMT Power Lower  TB30-9 Discrete Open Collector Input - A pull down to ground on this line indicates that the translator power is to be lowered. RMT  System Reflect Power TB30-10 Analog Output - 0 to 4.0 V- This is a buffered loop through of the calibrated “System Reflected Power ” and indicates the translator's reflected output power. The scale factor is 25 % / 3.2V. RMT System Visual/Forward Power TB30-11 Analog Output - 0 to 4.0 V- This is a buffered loop through of the calibrated “System Visual/Avg. Power ”.  Indicates the translator's Visual / Average power. Scale factor is 100 % / 3.2V. RMT System Aural Power TB30-12 Analog Output - 0 to 4.0 V- This is a buffered loop through of the calibrated “System Aural Power ”. Indicates the translator's forward Aural output power. The scale factor is 100 % / 3.2V. RMT Spare 1  TB30-13  Remote connection to spare module - Use is TBD. RMT Spare 2  TB30-14  Remote connection to spare module - Use is TBD.
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-14 Signal Name  Pin Designations  Signal Type/Description  System Reflect Power  TB31-13 Analog Input - 0 to 1.00 V- This is the input of the “System Reflected Power ” indicating the translator's reflected output power.  The scale factor is 25 % / 0.80V. System Visual / Forward Power  TB31-14 Analog Input - 0 to 1.00 V- This is the input of the “System Visual / Forward Power ” indicating the translator's forward Visual / Forward output power. The scale factor is 100 % / 0.80V. System Aural Power  TB31-15 Analog Input - 0 to 1.00 V- This is the input of the “System Aural Power ” indicating the translator's forward Aural output power. The scale factor is 100 % / 0.80V. IF Processor  IF Signal Select  TB31-3 Discrete Open Collector Input - A low indicates that the modulator IF source is to be used by the IF Processor module.  When floating an analog IP Processor module may use the Modulated IF Input if the IF Processor sled is so configured. IF Processor  DLC Voltage  TB31-4 Analog Output - 0 to 5.00 V- This is the input of IF Processor module for digital system RF output power control. UC AGC #2 Voltage  TB31-5 Auxiliary Analog Input - 0 to 1V- This voltage is used by the Upconverter for gain control.  Linear signal with display resolution of 0.01 %.  Primary signal source is J34-1. RMT Ground  TB30-15, and 17  Ground pins available through Remote  RMT Ground  TB31-1, 2,  6 to 12, and 17  Ground pins available through Remote  RMT +12 VDC  TB30-16 TB31-16 +12 VDC available through Remote w/ 2 Amp re-settable fuse RMT -12 VDC  TB30-18 TB31-18 -12 VDC available through Remote w/ 2 Amp re-settable fuse
Analog UHF Driver/Translator  Chapter 2, System Description &   Remote Control Connections LX Series, Rev. 0  2-15              Table 2-26. Receiver Tray hard wired Remote Connections thru J3 a 15-pin, D-Connector located on the rear of the tray   Signal Name  Pin Designations  Signal Type/Description ALC Voltage (+)  J3-3  ALC Voltage output ALC Voltage (-)  J3-4  ALC Voltage output ground return  J3 Remote Connections

Navigation menu