UTC Fire and Security AA3 RCR-50, RCR-PET, RCR-C User Manual 1035261D RCR A C I I P65

UTC Fire & Security B.V. RCR-50, RCR-PET, RCR-C 1035261D RCR A C I I P65

Contents

Manual 1

Download: UTC Fire and Security AA3 RCR-50, RCR-PET, RCR-C User Manual 1035261D RCR A C I I P65
Mirror Download [FCC.gov]UTC Fire and Security AA3 RCR-50, RCR-PET, RCR-C User Manual 1035261D RCR A C I I P65
Document ID1485946
Application IDiE/3P8z529Lm/yvDnVj1eA==
Document DescriptionManual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize44.09kB (551111 bits)
Date Submitted2011-06-20 00:00:00
Date Available2011-06-21 00:00:00
Creation Date2004-04-07 14:22:42
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2011-06-17 09:09:16
Document Title1035261D_RCR_A_C_I.I.P65
Document CreatorPageMaker 6.5
Document Author: 208037844

PrecisionLine
Dual Technology Motion Sensor
Models: RCR-A (Form A)
RCR-C (Form C)
Installation Instructions
Description
CO
NO
PR
PR
SP
TM
TM
PrecisionLine dual technology sensors combine range-controlled
radar (RCR) technology with a passive infrared (PIR) system to
increase false alarm immunity by allowing them to sense humansized objects within a specified range. Both the RCR and PIR
systems must be triggered to set off an alarm, unless in stealth mode
(radar-only).
The detector is designed to use a 12VDC power supply provided
by a UL Listed alarm control panel.
Figure 2. Detector (exploded)
Features
Parts
The detector provides the following features:
The following parts are included with the detector:
• RCR detector
• 1 screw to join the case halves
• 3 factory-installed jumpers
• Stealth Mode (radar only) - Internal jumper allows you to
disable the PIR, and use the radar only to detect intruders faster.
This mode can be used for covert installations (mounted behind
walls).
• Selectable range up to 35 feet (10.7m) - Internal jumper
allows radar range selection to optimize coverage.
• LED indicator - A multi-color LED provides detector status.
• Tamper switch (RCR-C only) - Activated when the pins on the
circuit board are removed from the terminal sockets on the base.
27’
(8.2m)
• DO NOT place any objects in front of the detector that may
prevent a clear line of sight. Not applicable in High Security
Mode (radar only).
9’
(2.7m)
0’
90°
9’
(2.7m)
18’
(5.5m)
27’
(8.2m)
Radar Viewing Area
35’
(10.7m)
Side View
PIR Viewing Area
6.9’
(2.1m)
9’
(2.7m)
• Mount the detector so the expected movement of an intruder is
across the detection pattern. See Figure 1.
• DO NOT mount the detector within 2 feet (0.6m) of any metallic
objects or within 5 feet (1.5m) of any florescent lights.
18’
(5.5m)
0’
The detector can be mounted in a corner or on a flat wall. Use the
following guidelines to determine the best location to install the
detector:
• Mount the detector on a stable surface 7 to 9 feet (2.1 to 2.7m)
high.
35’
(10.7m)
Top View
Selecting a Location for the Detector
18’
(5.5m)
27’
(8.2m)
35’
(10.7m)
Figure 1. RCR and PIR Coverage Patterns
PrecisionLine RCR-A/RCR-C
• Avoid locations that expose the detector to possible false alarm
sources such as:
– Moving or vibrating objects (fans, pulleys, conveyor belts)
– Electronic fields (electric motors, high voltage equipment)
– Water spray or corrosive environments
– Heat sources in the field of view (heaters, radiators)
– Windows in the field of view
– Strong air drafts on the detector (fans, air conditioners)
• When installing multiple detectors:
– DO NOT mount detectors facing each other.
– Mount them at least 20 feet (6.1m) apart.
– Use shorter range settings to avoid overlapping radar coverage.
– Mounting sensors back to back is not recommended, but if
an application requires such mounting, use the 9-foot (2.7m)
range, mount at least 1foot (0.3m) apart, and walk test the
installation to ensure proper operation.
Installing the Detector
All wiring must conform to National Electric Code (NEC) and/or
local codes having jurisdiction.
Terminal
sockets
Important: DO NOT use this device for safety
interlock applications.
Spare
RCR-C only
Use the following steps to install the detector:
1.
Run the security system wiring to the detector location.
2.
To remove the front cover/electronic module, press down on
the lever at the bottom of the unit and pull the cover off.
Remove the nameplate and loosen the screw if necessary. To
remove the nameplate, insert a small screwdriver into one of
the nameplate side slots and gently push in on the nameplate.
See Figure 2.
CAUTION
You must be free of all static electricity before
handling sensor circuit boards. Touch a grounded,
bare metal surface before touching circuit boards or
wear a grounding strap
3.
If necessary, set the jumpers on the circuit board. See Setting
the Jumpers.
4.
Remove the appropriate wiring and mounting knockout holes
from the back cover. The detector can be mounted on a flat
wall or in a corner. See Figure 3.
5.
Pull the wires through the knockout holes and use screws to
attach the base to the wall. Use screw anchors if necessary.
6.
Strip 1/4 inch (6.4mm) of insulation from each wire.
7.
Run each wire through the strain relief and into the appropriate
screw terminals on the base. Tighten the screws. See Figure 3.
8.
Line up the tabs on the bottom of the cover/electronic module
with the corresponding tabs on the bottom of the base and
snap the cover/electronic module firmly down onto the base.
9.
Tighten the screw and replace the nameplate. See Figure 2.
Flatwall-mount
knockout
Wire
Strain relief
Corner-mount
knockouts
Corner-mount
knockouts
Wiring knockout
Flat-wall mount
knockout
Figure 3. Detector Base
10. Apply power. The green LED should light for approximately
25 seconds and then go out.
J4
11. Walk test the coverage pattern as follows:
Radar
only
– Walk throughout the intended coverage area.
– Verify the detector alarms. See Understanding the LED.
Note
Most units walk test more accurately if the person
testing waits 10 seconds between tripping the unit and
walking again. This allows the detector to stabilize
between trips.
J2
J3
LED
Disable
Range
Figure 4. Main Circuit Board
PrecisionLine RCR-A/RCR-C
Setting the Jumpers
SB01 Swivel Mount Bracket
The detector provides jumpers to select the detection range and PIR
and LED operation. See Figure 4.
For ceiling-mount applications that require 90 degree coverage, an
optional ceiling-mount swivel bracket (SB01) is available from GE
Interlogix. See Figure 5.
J2 Range - Use the jumper to cover the center pin and the pin
indicating the desired range. No jumper = 35 feet (10.7m)
and under.
35 feet (10.7m) and under
(factory default)
27 feet (8.2m)and under
35’
(10.7m)
35’
(10.7m)
27’
(8.2m)
27’
(8.2m)
9’
(2.7m)
9’
(2.7m)
18’
(5.5m)
18’
(5.5m)
18 feet (5.5m)and under
9 feet (2.7m) and under
35’
(10.7m)
35’
(10.7m)
Figure 5. SBO1 Swivel-Mount Bracket
9’
(2.7m)
27’
(8.2m)
9’
(2.7m)
27’
(8.2m)
18’
(5.5m)
18’
(5.5m)
Maintaining the Detector
Important: You need to set J2 as close to the intended
coverage range as possible. Overshooting the
coverage area may cause false alarms.
J3 LED -
When installed and used properly, the detector provides years of
service with minimal maintenance. You should walk test the
detector annually to ensure proper operation.
When the cover is removed, power is interrupted to the sensor.
Once the cover has been replaced, the green LED will illuminate for
25 seconds while the sensor warms up. After the green LED goes
off, wait one minute and walk test the sensor.
Understanding the LED
ON = LED enabled (factory default)
OFF = LED disabled
J4 PIR -
The multi-color LED located on the bottom of the detector indicates
the status of the unit as described in the following table.
LED
Status
Red
PIR and radar detection. The detector is in
alarm and the relay has switched.
Green
PIR detection only (no alarm).
Yellow
Radar detection only (no alarm).
ON = Radar only enabled
OFF = PIR and radar enabled (factory default)
In Stealth Mode (radar only):
PrecisionLine RCR-A/RCR-C
LED
Status
Red
Radar detection.
Specifications
Input voltage
8.5 to 18 VDC (UL: 10 to 16VDC)
Typical current
20mA
Maximum current
27mA
Electrical configuration
RCR-A: Form A
RCR-C: Form C
Relay rating
RCR-A: 40VDC, 300mA max., 6W Load max.
RCR-C: 40VDC, 150mA max., 5W Load max.
Tamper (RCR-C only)
100ma, 40VDC
Detection range
35' (10.7 m) x 90°
Target velocity
0.5 ft/sec to 5 ft/sec
Alarm duration
5 sec
Mounting height
7' to 9' (2.1m to 2.7m)
Operating temperature
32° to 122°F (0° to 50°C)
Relative humidity
5 to 93% non-condensing
Dimensions:
Width
Depth
Height
Weight
6 oz (170g)
2.8" (7.1cm)
2.3" (5.7cm)
5.1" (13cm)
Color
White
Field wiring size
12-24 AWG
Radar frequency
5.8GHz
Listing
C-UL US
FCC Compliance
This device complies with Part 15 of the FCC rules. Operation is subject to the following three conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including interference that may cause undesired
operation.
(3) Changes or modifications not expressly approved by the party responsible for complicance could void the
user’s authority to operate the equipment.
FCC ID: CGGAA3
Product Ordering
Model Number
Description
RCR-A
PrecisionLine dual technology utilizing range-controlled radar, passive infrared technology with form A
relay, stealth mode (radar only), selectable range of 9, 18, 27, and 35 feet.
RCR-C
PrecisionLine dual technology utilizing range-controlled radar, passive infrared technology with form C
relay, stealth mode (radar only), tamper contacts, selectable range of 9, 18, 27, and 35 feet.
Accessories
SB01
Swivel-mount bracket
g GE Security
GE Security
12345 SW Leveton Drive
Tualatin, OR 97062
503-692-4052
USA & Canada: 800-547-2556
Tech Support
800-648-7424
FaxBack: 800-483-2495
www.ge-security.com
1035261 Rev D 04/04

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 4
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Producer                        : Acrobat Distiller 5.0 (Windows)
Create Date                     : 2004:04:07 14:22:42Z
Modify Date                     : 2011:06:17 09:09:16+02:00
Metadata Date                   : 2011:06:17 09:09:16+02:00
Creator Tool                    : PageMaker 6.5
Format                          : application/pdf
Creator                         : 208037844
Title                           : 1035261D_RCR_A_C_I.I.P65
Document ID                     : uuid:9f4eac76-f7d3-4981-ad11-fe0a2319060d
Instance ID                     : uuid:a244cee8-75c9-409e-a233-117c6c390dff
Author                          : 208037844
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CGGAA3

Navigation menu