1PrecisionLine RCR-A/RCR-CDescriptionPrecisionLine dual technology sensors combine range-controlledradar (RCR) technology with a passive infrared (PIR) system toincrease false alarm immunity by allowing them to sense human-sized objects within a specified range. Both the RCR and PIRsystems must be triggered to set off an alarm, unless in stealth mode(radar-only).The detector is designed to use a 12VDC power supply providedby a UL Listed alarm control panel.Features The detector provides the following features:•Stealth Mode (radar only)  - Internal jumper allows you todisable the PIR, and use the radar only to detect intruders faster.This mode can be used for covert installations (mounted behindwalls).•Selectable range up to 35 feet (10.7m) - Internal jumperallows radar range selection to optimize coverage.•LED indicator - A multi-color LED provides detector status.•Tamper switch (RCR-C only) - Activated when the pins on thecircuit board are removed from the terminal sockets on the base.PartsThe following parts are included with the detector:•RCR detector•1 screw to join the case halves•3 factory-installed jumpersSelecting a Location for the DetectorThe detector can be mounted in a corner or on a flat wall. Use thefollowing guidelines to determine the best location to install thedetector:•Mount the detector so the expected movement of an intruder isacross the detection pattern. See Figure 1.•Mount the detector on a stable surface 7 to 9 feet (2.1 to 2.7m)high.•DO NOT mount the detector within 2 feet (0.6m) of any metallicobjects or within 5 feet (1.5m) of any florescent lights.•DO NOT place any objects in front of the detector that mayprevent a clear line of sight. Not applicable in High SecurityMode (radar only).•Avoid locations that expose the detector to possible false alarmsources such as:– Moving or vibrating objects (fans, pulleys, conveyor belts)– Electronic fields (electric motors, high voltage equipment)– Water spray or corrosive environments– Heat sources in the field of view (heaters, radiators)– Windows in the field of view– Strong air drafts on the detector (fans, air conditioners)•When installing multiple detectors:– DO NOT mount detectors facing each other.– Mount them at least 20 feet (6.1m) apart.– Use shorter range settings to avoid overlapping radar coverage.– Mounting sensors back to back is not recommended, but ifan application requires such mounting, use the 9-foot (2.7m)range, mount at least 1foot (0.3m) apart, and walk test theinstallation to ensure proper operation.SPR TMPR TMPR NO COMFigure 2.  Detector (exploded)Figure 1. RCR and PIR Coverage Patterns90°Radar Viewing AreaPIR Viewing AreaTop ViewSide View35’(10.7m)35’(10.7m)27’(8.2m)27’(8.2m)18’(5.5m)18’(5.5m)9’(2.7m)9’(2.7m)0’0’35’(10.7m)27’(8.2m)18’(5.5m)9’(2.7m)6.9’(2.1m)PrecisionLineDual Technology Motion SensorModels: RCR-A (Form A)RCR-C (Form C)Installation Instructions
2PrecisionLine RCR-A/RCR-CInstalling the DetectorAll wiring must conform to National Electric Code (NEC) and/orlocal codes having jurisdiction.Important: DO NOT use this device for safetyinterlock applications.Use the following steps to install the detector:1. Run the security system wiring to the detector location.2. To remove the front cover/electronic module, press down onthe lever at the bottom of the unit and pull the cover off.Remove the nameplate and loosen the screw if necessary. Toremove the nameplate, insert a small screwdriver into one ofthe nameplate side slots and gently push in on the nameplate.See Figure 2.CAUTIONYou must be free of all static electricity beforehandling sensor circuit boards. Touch a grounded,bare metal surface before touching circuit boards orwear a grounding strap3. If necessary, set the jumpers on the circuit board. See Settingthe Jumpers.4. Remove the appropriate wiring and mounting knockout holesfrom the back cover. The detector can be mounted on a flatwall or in a corner. See Figure 3.5. Pull the wires through the knockout holes and use screws toattach the base to the wall. Use screw anchors if necessary.6. Strip 1/4 inch (6.4mm) of insulation from each wire.7. Run each wire through the strain relief and into the appropriatescrew terminals on the base. Tighten the screws. See Figure 3.8. Line up the tabs on the bottom of the cover/electronic modulewith the corresponding tabs on the bottom of the base andsnap the cover/electronic module firmly down onto the base.9. Tighten the screw and replace the nameplate. See Figure 2.10. Apply power. The green LED should light for approximately25 seconds and then go out.11. Walk test the coverage pattern as follows:– Walk throughout the intended coverage area.– Verify the detector alarms. See Understanding the LED.NoteMost units walk test more accurately if the persontesting waits 10 seconds between tripping the unit andwalking again. This allows the detector to stabilizebetween trips.Figure 3. Detector BaseTerminalsocketsSpareRCR-C onlyFlatwall-mountknockoutCorner-mountknockoutsStrain reliefWiring knockoutFlat-wall mountknockoutWireCorner-mountknockoutsFigure 4. Main Circuit BoardRadar onlyJ4J3J2LEDDisableRange
3PrecisionLine RCR-A/RCR-CUnderstanding the LEDThe multi-color LED located on the bottom of the detector indicatesthe status of the unit as described in the following table.Maintaining the DetectorWhen installed and used properly, the detector provides years ofservice with minimal maintenance. You should walk test thedetector annually to ensure proper operation.When the cover is removed, power is interrupted to the sensor.Once the cover has been replaced, the green LED will illuminate for25 seconds while the sensor warms up. After the green LED goesoff, wait one minute and walk test the sensor.SB01 Swivel Mount BracketFor ceiling-mount applications that require 90 degree coverage, anoptional ceiling-mount swivel bracket (SB01) is available from GEInterlogix. See Figure 5.Figure 5.  SBO1 Swivel-Mount BracketSetting the JumpersThe detector provides jumpers to select the detection range and PIRand LED operation. See Figure 4.J2 Range - Use the jumper to cover the center pin and the pinindicating the desired range. No jumper = 35 feet (10.7m)and under.35 feet (10.7m) and under 27 feet (8.2m)and under(factory default)18 feet (5.5m)and under 9 feet (2.7m) and underIn Stealth Mode (radar only):LED StatusRed Radar detection.Important: You need to set J2 as close to the intendedcoverage range as possible. Overshooting thecoverage area may cause false alarms.J3 LED -ON = LED enabled (factory default)OFF = LED disabledJ4 PIR -ON = Radar only enabledOFF = PIR and radar enabled (factory default)9’(2.7m)18’(5.5m)35’(10.7m)27’(8.2m)9’(2.7m)18’(5.5m)35’(10.7m)27’(8.2m)9’(2.7m)18’(5.5m)35’(10.7m)27’(8.2m)9’(2.7m)18’(5.5m)27’(8.2m)35’(10.7m)LED StatusRed PIR and radar detection. The detector is inalarm and the relay has switched.Green PIR detection only (no alarm).Yellow Radar detection only (no alarm).
SpecificationsInput voltage 8.5 to 18 VDC (UL: 10 to 16VDC)Typical current 20mAMaximum current 27mAElectrical configuration RCR-A: Form ARCR-C: Form CRelay rating RCR-A: 40VDC, 300mA max., 6W Load max.RCR-C: 40VDC, 150mA max., 5W Load max.Tamper (RCR-C only) 100ma, 40VDCDetection range 35' (10.7 m) x 90°Target velocity 0.5 ft/sec to 5 ft/secAlarm duration 5 secMounting height 7' to 9' (2.1m to 2.7m)Operating temperature 32° to 122°F (0° to 50°C)Relative humidity 5 to 93% non-condensingDimensions: Width 2.8" (7.1cm)Depth 2.3" (5.7cm)Height 5.1" (13cm)Weight 6 oz (170g)Color WhiteField wiring size 12-24 AWGRadar frequency 5.8GHzListing C-UL USFCC ComplianceThis device complies with Part 15 of the FCC rules. Operation is subject to the following three conditions:(1) This device may not cause harmful interference(2) This device must accept any interference received, including interference that may cause undesiredoperation.(3) Changes or modifications not expressly approved by the party responsible for complicance could void theuser’s authority to operate the equipment.FCC ID: CGGAA31035261 Rev D   04/04Product Ordering  Model Number Description  RCR-A PrecisionLine dual technology utilizing range-controlled radar, passive infrared technology with form Arelay, stealth mode (radar only), selectable range of 9, 18, 27, and 35 feet.  RCR-C PrecisionLine dual technology utilizing range-controlled radar, passive infrared technology with form Crelay, stealth mode (radar only), tamper contacts, selectable range of 9, 18, 27, and 35 feet.  Accessories  SB01 Swivel-mount bracketTech Support800-648-7424FaxBack: 800-483-2495www.ge-security.comGE Security12345 SW Leveton DriveTualatin, OR 97062503-692-4052USA & Canada: 800-547-2556GE Security g

Navigation menu