UTC Fire and Security AA3 RCR-50, RCR-PET, RCR-C User Manual 1037946C RCR PET I I P65

UTC Fire & Security B.V. RCR-50, RCR-PET, RCR-C 1037946C RCR PET I I P65

Contents

Manual 3

1PrecisionLine RCR-PETPrecisionLine RCR-PETDual Technology Motion SensorInstallation InstructionsDescriptionPrecisionLine dual technology motion sensors combinerange-controlled radar (RCR) technology with a passiveinfrared (PIR) system to increase false alarm immunity byallowing them to sense human-sized objects within a speci-fied range. Both the RCR and PIR systems must be triggeredto set off an alarm.The sensor is designed to use a 12VDC power supplyprovided by a UL Listed control panel.Features The sensor provides the following features:•Pet Immune up to 80 lbs.•Selectable range up to 35 feet (10.7m) - Internal jumperallows radar range selection to optimize coverage.•LED indicator - A multi-color LED provides detectorstatus.• Opaque Fresnel lens - Blocks visible light.PartsThe following parts are included with the sensor:• RCR-PET sensor•1 screw to join the case halves•2 factory-installed jumpersSelecting a Location for the SensorThe sensor can be mounted in a corner or on a flat wall. Usethe following guidelines to determine the best location toinstall the sensor:•Mount the sensor so the expected movement of anintruder is within a 90-degree radius in front of the sensor.See Figure 2.•Mount the sensor on a stable surface 7 to 8 feet (2.1 to2.4m) high.•DO NOT mount the sensor within 2 feet (0.6m) of metallicobjects.•DO NOT place objects in front of the sensor that mayprevent a clear line of sight.•Avoid locations that expose the sensor to possible falsealarm sources such as:– Moving or vibrating objects (fans, pulleys, conveyor belts)– Electronic fields (electric motors, high voltage equipment)– Water spray or corrosive environments– Heat sources (heaters, radiators) in the field of view– Windows in the field of view– Strong air drafts on the sensor (fans, air conditioners)Figure 1. Sensor (exploded)Figure 2 - RCR and PIR Coverage Patterns60° 30° 15°4°7’ (2.1m)90°35’(10.7m)35’(10.7m)27’(8.2m)27’(8.2m)18’(5.5m)18’(5.5m)9’(2.7m)9’(2.7m)0’0’Top ViewSide Viewfloor lineRadarPIR
2PrecisionLine RCR-PETFigure 3. Sensor Base•When installing multiple sensors:– DO NOT mount sensors facing each other.– Mount them at least 20 feet (6.1m) apart.– Mounting sensors back to back is not recommended, butif an application requires such mounting, use the 9-foot(2.7m) range, mount at least 1foot (0.3m) apart, and walk testthe installation to ensure proper operation.Installing the SensorAll wiring must conform to the National Electric Code (NEC)and/or local codes having jurisdiction.Important: DO NOT use this device for safety interlockapplications.Use the following steps to install the sensor:1. Run the security system wiring to the sensor location.2. Lift off the front cover/electronic module. Remove thenameplate and loosen the screw if necessary. SeeFigure 1.CAUTIONYou must be free of all static electricity beforehandling sensor circuit boards. Touch agrounded, bare metal surface before touchingcircuit boards or wear a grounding strap.3. If necessary, set the jumpers on the circuit board. SeeSetting the Jumpers.4. Remove the appropriate wiring and mounting knock-outs  from the back cover. The sensor can be mountedon a flat wall or in a corner. See Figure 3.5. Pull the wires through the knockout holes and use thetwo screws provided to attach the base to the wall. Usescrew anchors if necessary.6. Strip 1/4 inch (6.4 mm) of insulation from each wire.7. Run each wire through the strain relief and under theappropriate screw terminals on the base and tightenthe screws. See Figure 3.8. Line up the tabs on the bottom of the cover/electronicmodule with the corresponding tabs on bottom of thebase and snap the cover/electronic module firmly downonto the base.9. Tighten the screw and replace the nameplate. SeeFigure 1.10. Apply power. The LED should light green for approxi-mately 25 seconds and then go out.11. Walk test the coverage pattern as follows:– Walk throughout the intended coverage area.– Verify the sensor alarms. See Understanding the LED.Figure 4. Main Circuit BoardJ3J2J2 RangeJ3 LEDDisableTerminalsocketsCorner-mountknockoutsFlat wall-mountknockoutFlat wall-mountknockoutWiringknockoutStrain reliefCorner-mountknockouts
3PrecisionLine RCR-PETUnderstanding the LEDThe multi-color LED located on the bottom of the sensorindicates the status of the unit as described in the followingtable.Maintaining the SensorWhen installed and used properly, the sensor providesyears of service with minimal maintenance. You should walktest the sensor annually to ensure proper operation.SB01 Swivel Mount BracketFor ceiling-mount applications that require 90 degreecoverage, an optional ceiling-mount swivel bracket (SB01) isavailable. See Figure 5.Figure 5. SB01 Swivel-Mount BracketAfter 30 minutes the LED will only indicate an alarm condi-tion. Drop power to reset the walktest timer.(Pet immunity not verified by UL.)riahgnoL pu)gnol"2( .sbl08otriahmuideM )gnol"5.1( .sbl05otpuriahtrohS otpu)gnol"1( .sbl03dednemmocertoNyellatepesU noitacilppakoonihCeilloCijnesaBnamreboDyksuHretteShsilgnEreirreTredroBenaDtaerGeldooPretnioPleinapSrekcoCdnuohyerGreveirteRguPgodlluBhcnerFffitsaMgodpeehSeldooPyoTreirreTlluBiniMlluBtiPdrehpehSrenaremieWigroChsleWdranreB.tSstaCPet ImmunityWhen mounted properly, the RCR-PET sensor provides falsealarm immunity to dogs and similar animals. The size andtemperature of the animal, which is affected by the length ofthe animal’s coat, affects the immunity to false alarms. Dogsvary in body temperature by breed, a very warm-blooded dogwith short hair will not be as immune to false alarms as asimilar sized dog with long hair. Therefore, the acceptableshort hair dog is limited to a smaller (lighter) weight dog. Seethe examples listed in the following table:Important: You need to set J2 as close to the intendedcoverage range as possible. Overshooting the coveragearea may cause false alarms.J3 LED -ON = LED enabled (factory default)OFF = LED disabledSetting the JumpersThe sensor provides jumpers to select the detection rangeand LED operation. See Figure 4.J2 Range - Use the jumper to cover the center pin and the pinindicating the desired range. No jumper = 27 feet (8.2m) andunder.35 feet (10.7m) and under 27 feet (8.2m) and under            (Factory default)18 feet (5.5m)and under          9 feet (2.7m) and under9’(2.7m) 9’(2.7m)18’(5.5m) 18’(5.5m)35’(10.7m) 35’(10.7m)27’(8.2m) 27’(8.2m)9’(2.7m)9’(2.7m)18’(5.5m)18’(5.5m)35’(10.7m) 35’(10.7m)27’(8.2m) 27’(8.2m)LED StatusRed PIR and RCR detection. The sensor is inalarm and the relay has switched.Green PIR detection only (no alarm).Yellow RCR detection only (no alarm).
SpecificationsInput voltage 8.5 to 18VDC (UL: 10 to 16VDC)Typical current 20mAMaximum current 27mAElectrical configuration Form ARelay rating 40VDC, 300mA max.,6W Load max.Detection range 35' (10.7m) x 90°Target velocity 0.5 ft/sec to 5 ft/secAlarm duration 5 sec. ± 10%Mounting  height 7' to 8' (2.1m to 2.4m)Operating temperature 32°F to 122°F (0°C to 50°C)Relative humidity 5 to 93%  non-condensingDimensionsWidth 2.8" (71mm)Height 5.1" (130mm)Depth 2.3" (58mm)Weight 6 oz (170g)Color WhiteField wiring size 12-24 AWGListings C-UL USFCC ComplianceThis device complies with Part 15 of the FCC rules.Operation is subject to the following two conditions:(1) This device may not cause harmful interference.(2) This device must accept any interference received,in-cluding interference that may cause undesired operation.FCC ID: CGGAA3Product OrderingModel Number DescriptionRCR-PET PrecisionLine Dual Technology Motion Sensor with Pet Immunity up to 80 lbs., Form AAccessoriesSB01 Swivel-Mount Bracket1037946 Rev C  04/04Tech Support800-648-7424FaxBack: 800-483-2495www.ge-security.comGE Security12345 SW Leveton DriveTualatin, OR 97062503-692-4052USA & Canada: 800-547-2556GE Security g

Navigation menu