UTC Fire and Security AA3 RCR-50, RCR-PET, RCR-C User Manual 1036806B RCR50 I I P65

UTC Fire & Security B.V. RCR-50, RCR-PET, RCR-C 1036806B RCR50 I I P65

Contents

Manual 2

Download: UTC Fire and Security AA3 RCR-50, RCR-PET, RCR-C User Manual 1036806B RCR50 I I P65
Mirror Download [FCC.gov]UTC Fire and Security AA3 RCR-50, RCR-PET, RCR-C User Manual 1036806B RCR50 I I P65
Document ID1485947
Application IDiE/3P8z529Lm/yvDnVj1eA==
Document DescriptionManual 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize44.31kB (553820 bits)
Date Submitted2011-06-20 00:00:00
Date Available2011-06-21 00:00:00
Creation Date2004-04-12 13:18:26
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2011-06-17 09:09:36
Document Title1036806B_RCR50_I.I.P65
Document CreatorPageMaker 6.5
Document Author: 208037844

PrecisionLine RCR-50
Dual Technology Motion Sensor
Installation Instructions
Description
CO
NO
PR
PR
TM
TM
SP
The RCR detector combines range-controlled radar (RCR)
technology with a passive infrared (PIR) system to increase
false alarm immunity by allowing it to sense human-sized
objects within a specified range. Both the RCR and PIR
systems must be triggered to set off an alarm, unless in radaronly mode.
The detector is designed to use a 12VDC power supply
provided by a UL Listed alarm control panel.
Features
The detector provides the following features:
• High-security (radar-only) mode - Internal jumper
allows you to disable the PIR, and use the radar-only
mode to detect intruders faster. This mode can be used for
covert installations (mounted behind ceiling panels or
walls).
Figure 2. Detector (Exploded)
Parts
The following parts are included:
• RCR detector
• 1 screw to join the case halves
• 3 factory-installed jumpers
Selecting a Location for the Detector
• Selectable range up to 50 feet (15.2m) - Internal jumper
allows radar range selection to optimize coverage.
The detector can be mounted in a corner or on a flat wall.
Use the following guidelines to determine the best location to
install the detector:
• LED indicator - A multi-color LED provides detector
status.
• Mount the detector so the expected movement of an
intruder is across the detection pattern. See Figure 1.
• Tamper switch - Activated when the pins on the circuit
board are removed from the terminal sockets on the base.
• Mount the detector on a stable surface 7 to 9 feet (2.1 to
2.7m) high.
• DO NOT mount the detector within 2 feet (0.6m) of
metallic objects or within 5 feet (1.5m) of florescent lights.
50’
(15.2m)
Top View
40’
(12.2m)
• DO NOT place objects in front of the detector that may
prevent a clear line of sight. (Not applicable in radar-only
mode.)
30’
(9.1m)
20’
(6.1m)
0’
• Avoid locations that expose the detector to possible false
alarm sources such as:
– Moving or vibrating objects (fans, pulleys, conveyor belts)
– Electronic fields (electric motors, high voltage equipment)
– Water spray or corrosive environments
– Heat sources in the field of view (heaters, radiators)
– Windows in the field of view
– Strong air drafts on the detector (fans, air conditioners)
90°
20’
(6.1m)
30’
(9.1m)
40’
(12.2m)
Radar Viewing Area
50’
(15.2m)
Side View
PIR Viewing Area
7’
2.1m
4°
0°
60°
30°
15°
Figure 1. Coverage Patterns
PrecisionLine RCR-50
floor line
• When installing multiple detectors:
– DO NOT mount detectors facing each other.
– Mount detectors at least 20 feet (6.1m) apart.
– Use shorter range settings to avoid overlapping radar
coverage.
– Mounting detectors back to back is not recommended, but
if an application requires such mounting, use the 20-foot
(6.1m) range and walk test the installation to ensure proper
operation.
Installing the Detector
All wiring must conform to the National Electric Code (NEC)
and/or local codes having jurisdiction.
Terminal
sockets
Important: DO NOT use this device for safety
interlock applications.
To install the detector:
1.
Run the security system wiring to the detector location.
2.
To remove the front cover/electronic module, remove the
nameplate and loosen the screw if necessary. To remove
the nameplate, insert a small screwdriver into one of the
nameplate side slots and gently push in and pry up with
the screwdriver. See Figure 2. Then press down on the
top of the front cover with one hand, while holding the
sides at the top of the back cover and squeezing in and
pulling back with the other hand.
Flatwall-mount
knockout
Strain relief
Corner-mount
knockouts
Corner-mount
knockouts
Wiring knockout
CAUTION
You must be free of all static electricity before
handling sensor circuit boards. Touch a
grounded, bare metal surface before touching
circuit boards or wear a grounding strap.
3.
If necessary, set the jumpers on the circuit board. See
Setting the Jumpers.
4.
Remove the appropriate wiring and mounting knockouts
from the back cover. The detector can be mounted on a
flat wall or in a corner. See Figure 3.
5.
Pull the wires through the knockout holes and use screws
to attach the base to the wall. Use screw anchors if
necessary.
6.
Strip 1/4 inch (6.4mm) of insulation from each wire.
7.
Run each wire through the strain relief and under the
appropriate screw terminals on the base and tighten the
screws. See Figure 3.
8.
Line up the tabs on the bottom of the cover/electronic
module with the corresponding tabs on bottom of the
base and snap the cover/electronic module firmly down
onto the base.
9.
Tighten the screw and replace the nameplate. See
Figure 2.
Wire
Flat-wall mount
knockout
Figure 3. Detector Base
J4
Radar
only
10. Apply power. The green LED should light for approximately 25 seconds and then go out.
11. Walk test the coverage pattern as follows:
– Walk throughout the intended coverage area.
– Verify the detector alarms. See Understanding the LED.
Note
Most units walk test more accurately if the person
testing waits 10 seconds between tripping the unit and
walking again. This allows the detector to stabilize
between trips.
J2
LED Disable
J3
Range
Figure 4. Main Circuit Board
PrecisionLine RCR-50
Setting the Jumpers
SB01 Swivel-Mount Bracket
The detector provides jumpers to select the detection range
and PIR and LED operation. See Figure 4.
For ceiling-mount applications that require 90 degree
coverage, an optional swivel-mount bracket (SB01) is
available from GE Security. See Figure 5.
J2 Range - Use the jumper to cover the center pin and the
pin indicating the desired range. No jumper = 50 feet (15.2m)
and under.
50 feet (15.2m) and under
(factory default)
40 feet (12.2m) and under
50’
(15.2m)
40’
(12.2m)
50’
(15.2m)
20’
(6.1m)
40’
(12.2m)
30’
(9.1m)
20’
(6.1m)
30’
(9.1m)
Figure 5. SBO1 Swivel-Mount Bracket
30 feet (9.1m) and under
20 feet (6.1m) and under
40’
(12.2m)
Maintaining the Detector
50’
15.2m)
50’
(15.2m)
20’
(6.1m)
20’
(6.1m)
40’
(12.2m)
30’
(9.1m)
30’
(9.1m)
Note
You need to set J2 as close to the intended
coverage range as possible. Overshooting the
coverage area may cause false alarms.
J3 LED -
When installed and used properly, the detector provides many
years of service with minimal maintenance. You should walk
test the detector annually to ensure proper operation.
Clean the inside of the unit with a soft-bristled brush or
compressed air. Clean the outside with a damp (water) cloth
as needed to keep it free of dust and dirt. Always test the
unit after cleaning.
When the cover is removed, power is interrupted to the
sensor. Once the cover has been replaced, the green LED will
illuminate for 25 seconds while the sensor warms up.After
the green LED goes off, wait one minute and walk test the
sensor.
ON = LED enabled (factory default)
Understanding the LED
OFF = LED disabled
J4 PIR ON = Radar only enabled
OFF = PIR and Radar enabled
(factory default)
The multi-color LED located on the bottom of the detector
indicates the status of the unit as described in the following
table.
LED
Status
Red
in
PIR and Radar detection. The detector is
alarm and the relay has switched.
Green
PIR detection only (no alarm).
Yellow
Radar detection only (no alarm).
In Radar-only mode:
PrecisionLine RCR-50
LED
Status
Red
Radar detection.
Specifications
FCC Compliance
Input voltage
8.5 to 18VDC (UL: 10 to 16VDC)
Typical current
27mA
Maximum current
35mA
Electrical configuration
Form C
Relay rating
28VDC, 100mA max.
Tamper
100ma, 40VDC
Detection range
50' (15.2m) x 90°
Target velocity
0.5 ft/sec to 5 ft/sec
Alarm duration
5 sec ± 10%
Mounting height
7' to 9' (2.1m to 2.7m)
Operating temperature
32° F to 122° F (0° C to 50° C)
This device complies with Part 15 of the FCC rules.
Operation is subject to the following three conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
(3) Changes or modifications not expressly approved
by the party responsible for complicance could void
the user’s authority to operate the equipment.
FCC ID: CGGAA3
Relative humidity
5 to 93% non-condensing
Dimensions:
2.8" (7.1cm) W
5.1" (13cm) H
2.3" (5.7cm) D
Weight
6 oz (170g)
Color
white
Field wiring size
12-24 AWG
Microwave frequency
5.8GHz
Listing
C-UL US
Product Ordering
Model Number
Description
RCR-50
Range-controlled radar, passive infrared detector with form C relay, stealth mode,
tamper contacts, 50 foot (15.2m) maximum range
Accessories
SB01
Swivel-mount bracket
g GE Security
GE Security
12345 SW Leveton Drive
Tualatin, OR 97062
503-692-4052
USA & Canada: 800-547-2556
Tech Support
800-648-7424
FaxBack: 800-483-2495
www.ge-security.com
1036806 Rev B 04/04

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 4
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Producer                        : Acrobat Distiller 5.0 (Windows)
Create Date                     : 2004:04:12 13:18:26Z
Modify Date                     : 2011:06:17 09:09:36+02:00
Metadata Date                   : 2011:06:17 09:09:36+02:00
Creator Tool                    : PageMaker 6.5
Format                          : application/pdf
Creator                         : 208037844
Title                           : 1036806B_RCR50_I.I.P65
Document ID                     : uuid:2e43cd4a-609d-4f3d-b1e0-831950a6e6ae
Instance ID                     : uuid:de73b00a-cae9-4c11-8083-fcfd0bb37d54
Author                          : 208037844
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CGGAA3

Navigation menu