PIR Ready VT7300 Series 24 Vac Low Voltage Fan Coil Thermostats For Commercial and Lodging HVAC Applications (Issue Date: June 16, 2008 – 028-0183_R3) Product overview The VT7300 PI thermostat family is specifically designed for fan coil control. The product features a backlit LCD display with dedicated function menu buttons for simple operation. Accurate temperature control is achieved due to the product’s PI proportional control algorithm, which virtually eliminates temperature offset associated with traditional, differential-based thermostats. Models are available for On/Off, 3 point floating and analog 0 to 10 Vdc control and can control up to three fan speed. Three additional inputs are also provided for monitoring and / or various advanced functions. All models feature configurable System and Fan button functions to meet all possible applications. They all contain an SPST auxiliary switch that can be used to control lighting or auxiliary reheat. The thermostats are also compatible with the new Viconics PIR cover accessories. Thermostats equipped with a PIR cover provide advanced active occupancy logic, which will automatically switch occupancy levels from Occupied to Stand-By and Unoccupied as required by local activity being present or not. This advanced occupancy functionality provides advantageous energy savings during occupied hours without sacrificing occupant comfort. All thermostats can be ordered with or without a factory installed PIR cover ( see ordering notes below ). The additional following documents are available at: www.viconics.com • • • • • PIR application information and examples, are available on document: APP-PIR-Guide-Exx PIR cover installation information is available on document: PIR Cover Installation-Exx Information on the LON models (VT73xxX5000E), is available on document ITG-VT7300-PIR-LON-Exx Information on the BACnet models (VT73xxX5000B), is available on document ITG-VT7300-PIR-BAC-Exx Information on the Wireless models (VT73xxX5000W), is available on documents: ITG-VWG-40-BAC-Exx and LIT-VWG-40-SETUP-Exx Application 2&4 Pipes On/Off RH sensor No Market 2 & 4 Pipes Floating & On/Off No Yes 2&4 Pipes On/Off No Commercial / Institution 2 & 4 Pipes Floating & On/Off No Hotels / Lodging Yes VT7355F5000(X) VT7305F5000(X) VT7350F5000(X) VT7300F5000(X) VT7355C5000(X) VT7305C5000(X) Numbers VT7305A5000(X) Part VT7350C5000(X) Viconics VT7300C5000(X) VT7300A5000(X) Models available 2 & 4 Pipes Analog 0-10 Vdc No Yes Commercial / Institution No Yes Hotels / Lodging Ordering Information Notes: (X) model number represents available communication options: X=none for Stand-alone, X=B for BACnet MS-TP, X=E for Echelon and X=W for Wireless Thermostats can be ordered with a factory installed PIR cover. Please use (5500) extension instead of the (5000) only extension.: Ex. VT7300C5500E. Thermostats ordered without a PIR cover can be retrofitted with a separate PIR accessory cover afterwards when required Features and benefits Features Benefits • Models available with internal humidity sensing ⇒ Increased occupant comfort through dehumidification • Advanced occupancy functions • 3 configurable inputs ⇒ Through the network or smart local occupancy sensing ⇒ Fully integrated advanced occupancy functionality with a PIR accessory cover ⇒ Adds functionality • Configurable sequences of operation ⇒ Single model meets more applications • Configurable fan functions button ⇒ Meets more applications with a single model • Unique configuration setup utility ⇒ Minimizes parameter tampering • Multi level lockable keypad • Available for 24 Vac On/Off, Floating or Analog control ⇒ Tamper proof, no need for thermostat guards ⇒ Increased occupant comfort in cooling mode by reducing humidity and offer less fan noise in all mode of operation ⇒ Meet advanced applications requirements • Auxiliary output ⇒ Can be used for lighting or reheat • Ready for PIR accessory cover • Auto Fan speed mode 028-0183 R3_LIT-VT7300-PIR-E03.doc www.viconics.com / sales@viconics.com Programmable BI/UI inputs overview Binary input #1 can be configured for the following functions: 1. (None): No function will be associated with the input 2. (Rem NSB): remote NSB timer clock input. The scheduling will now be set as per the binary input. It provides low cost setback operation via a dry contact • Contact opened = Occupied • Contact closed = Unoccupied 3. (Motion NO) and (Motion NC): Advanced PIR occupancy functions using a Normally Open (NO) or Normally Closed (NC) remote PIR motion sensor. Occupancy mode is now set as per applied PIR function and configuration. Application information and examples, are available on document: APP-PIR-Guide-Exx. This document will provide the installers and system designers with detailed examples on applications, parameter configuration information, sequence of operation, troubleshooting and diagnostic help required for the proper usage of the PIR accessory covers 4. (Window) EMS: Forces the system to disable any current heating or cooling action by the thermostat. The mode stays the same and the current setpoints are the same Occupied setpoints. Only the outputs are disabled. There is a Door/Window alarm displayed on the thermostat to indicate to the local tenant that the door/window needs to be closed for cooling or heating to resume. Use NC contact. • Contact opened = System disabled with local Window alarm • Contact closed = System enabled 3. (RemOVR): temporary occupancy remote override contact. This function disables the central button override function on the thermostat. The override function is now controlled by a manual remote momentarily closed contact. When configured in this mode, the input operates in a toggle mode. It is now possible to toggle between unoccupied & occupied setpoints for the amount of time set by parameter (TOccTime) temporary occupancy time. 4. 5. (Service): a backlit flashing Service alarm will be displayed on the thermostat LCD screen when the input is energized. It can be tied in to the AC unit control card, which provides an alarm in case of malfunction. • Contact opened = No alarm • Contact closed = Alarm displayed Universal input #3 can be configured for the following functions: 1. (None): No function will be associated with the input 2. (COC/NH) Change over dry contact. Normally Heat: Used for hot / cold water change over switching in 2 pipe systems. • Contact closed = Cold water present • Contact opened = Hot water present Only used and valid if system is setup as 2 pipes. Parameter ( Pipe No ) set as 2 pipes. Binary input #2 can be configured for the following functions: 1. (None): No function will be associated with the input 2. (Door Dry) Door contact & Motion detector: This configuration is only functional if binary input #1 is set to Motion NO or Motion NC or a PIR accessory cover is used. With this sequence enabled, the occupancy is now dictated through those 2 inputs. Any motion detected will set the zone to occupied status. The zone will remain permanently in occupied mode until the door contact switch opens momentarily. The thermostat will then go in stand-by mode. If more movements are detected, the occupied mode will resume. While the door is opened, any movements detected by the remote PIR sensor or the PIR accessory cover will be ignored. Use a Normally Closed contact switching device. • Contact opened = Door opened • Contact closed = Door closed (Filter): a backlit flashing Filter alarm will be displayed on the thermostat LCD screen when the input is energized. It can be tied to a differential pressure switch that monitor filters • Contact opened = No alarm • Contact closed = Alarm displayed 3. (COC/NC) Change over dry contact. Normally Cool: Used for hot / cold water or air change over switching in 2 pipe systems. • Contact closed = Hot water present • Contact opened = Cold water present Only used and valid if system is setup as 2 pipes. Parameter ( Pipe No ) set as 2 pipes. 4. • (COS) Change over analog sensor: Used for hot / cold water or air change over switching in 2 pipe systems. Only used and valid if system is setup as 2 pipes. Parameter ( Pipe No ) set as 2 pipes. If temperature is > 77 °F = Hot water present • If temperature is < 75 °F = Cold water present 5. (SS) Supply air sensor monitoring: Used for supply air temperature monitoring. Only used for network reporting of the supply air temperature. Has no internal function in the thermostat. 3 Installation • • • • Remove security screw on the bottom of thermostat cover. Open up by pulling on the bottom side of thermostat. Remove Assembly and remove wiring terminals from sticker. (Fig. 3) Please note the FCC ID and IC label installed in the cover upon removal of cover for the wireless products. A) 12345- Location: Should not be installed on an outside wall. Must be installed away from any heat source. Should not be installed near an air discharge grill. Should not be affected by direct sun radiation. Nothing must restrain vertical air circulation to the thermostat. B) Installation: 1- Swing open the thermostat PCB to the left by pressing the PCB locking tabs. (Fig. 4) 2- Pull out cables 6” out of the wall. 3- Wall surface must be flat and clean. 4- Insert cable in the central hole of the base. 5- Align the base and mark the location of the two mounting holes on the wall. Install proper side of base up. 6- Install anchors in the wall. 7- Insert screws in mounting holes on each side of the base. (Fig. 4) 8- Gently swing back the circuit board on the base and push on it until the tabs lock it. 10- Strip each wire 1/4 inch. 11- Insert each wire according to wiring diagram. 13- Gently push back into hole excess wring (Fig. 5) 14- Re-Install wiring terminals in correct location. (Fig. 5) 15- Reinstall the cover (top side first) and gently push back extra wire length into the hole in the wall. 16- Install security screw. Fig.3 Location of PCB retaining tabs Fig.4 Re-install terminal blocks Fig.5 Thermostat assembly (VT7300F5000B shown) • • • • • If replacing an old thermostat, label the wires before removal of the old thermostat. Electronic controls are static sensitive devices. Discharge yourself properly before manipulation and installing the thermostat. Short circuit or wrong wiring may permanently damage the thermostat or the equipment. Anti-short cycling can be set to 0 minutes for equipment that posses their own anti cycling timer. Do not use that value unless the equipment is equipped with such internal timer. Failure to do so can damage the equipment. All VT7000 series thermostats are to be used only as operating controls. Whenever a control failure could lead to personal injury and/or loss of property, it becomes the responsibility of the user to add safety devices and/or alarm system to protect against such catastrophic failures. Fig.6 4 Terminal identification Viconics Part Numbers Description / Application VT73xxA5x00(x) 2 & 4 Pipe On/Off VT73xxC5x00(x) 2 & 4 Pipe Floating 2 & 4 Pipe On/Off Internal Temperature Internal Humidity 1- High Fan Speed 2- Medium Fan Speed 3- Low Fan Speed 4- 24 V~ Hot 5- 24 V~ Com 6- Aux BO 5 7- Aux BO 5 8- BO 3 Open Heat 9- BO 4 Close Heat 10- BO 1 Open Cool 11- BO 2 Close Cool 12- BI #1 13- RS 14- Scom 15- BI #2 16- UI #3 COS / COC /SS Viconics Number Description / Application VT73xxF5x00(x) 2 & 4 Pipe Analog Model Dependent Internal Temperature Internal Humidity Model Dependent Fan-H Fan-M Fan-L 24 V~ Hot 24 V~ Com Fan-H Fan-M Fan-L 24 V~ Hot 24 V~ Com 1- High Fan Speed 2- Medium Fan Speed 3- Low Fan Speed 4- 24 V~ Hot 5- 24 V~ Com Fan-H Fan-M Fan-L 24 V~ Hot 24 V~ Com BO 5-Aux BO 5-Aux BO 3 BO 5-Aux BO 5-Aux BO 3 BO 2 BI 1 RS Scom BI 2 UI 3 BO 4 BO 1 BO 2 BI 1 RS Scom BI 2 UI 3 6- Aux BO 5 7- Aux BO 5 9- AO 2 Heat 10- AO 1 Cool Not used Blank 12- BI #1 13- RS 14- Scom 15- BI #2 16- UI #3 COS / COC /SS Wiring Power & Fan ( All models ) 24 V~ transformer relay pack 3 speed 2 speed Single speed Fan-H High Fan-M Med Fan-L 24 V~ Hot Low High High Low 24 V~ Com Remote inputs ( All models ) BI 1 Remote wall sensor RS - S3010W1000 - S3020W1000 Scom BI 2 UI 3 Contact - Rem NSB - Motion - Window OR COC/NH - Normally heat - Closed contact = cold water COC/NC - Normally cool - Closed contact = heat water Contact - Door - Remote Override - Filter alarm - service alarm Auxiliary output ( All models ) - Dry contact to end device 24 V~ maximum #4 24 V~ Hot #5 24 V~ Com #6 #7 - 24 Vac power to relay #4 24 V~ Hot #5 24 V~ Com #6 #7 SS ( supply sensor ) - S1010E1000 - S2000D1000 COS ( changeover sensor ) - S1010E1000 BO 5-Aux BO 5-Aux AO 2 AO 1 Blank BI 1 RS Scom BI 2 UI 3 5 Main outputs wiring 2 Pipe applications 4 Pipe applications On-Off control VT7300A5x00(x) & VT7305AC5x00(x) 24 V~ Hot 24 V~ Com N.C. Heating / Cooling valve 24 Vac Com BO2 24 V~ Hot 24 V~ Com BO3 BO2 24 Vac Com N.O. Heating valve 24 Vac Com N.C. Cooling valve VT7300C5x00(x), VT7305C5x00(x), VT7350C5x00(x) & VT7355C5x00(x) 24 V~ Hot 24 V~ Com Heating / Cooling valve BO1 BO2 if N.O. if N.C. OR 24 Vac Com 24 V~ Hot 24 V~ Com BO3 if N.O. OR BO4 if N.C. BO1 if N.O. BO2 if N.C.OR 24 Vac Com Heating valve 24 Vac Com Cooling valve Floating control VT7300C5x00(x), VT7305C5x00(x), VT7350C5x00(x) & VT7355C5x00(x) 24 V~ Hot 24 V~ Com Heating / Cooling valve BO1 BO2 Open Com Close 24 V~ Hot 24 V~ Com BO3 BO4 BO1 BO2 Open Com Close Heating valve Open Com Close Cooling valve Analog control VT7300F5x00(x), VT7305F5x00(x), VT7350F5x00(x) & VT7355F5x00(x) 24 V~ Hot 24 V~ Com 24 V~ Hot 24 V~ Com Heating / Cooling valve AO 1 Com 24 Vac 0-10 Vdc AO 2 AO 1 Com 24 Vac 0-10 Vdc Heating valve Com 24 Vac 0-10 Vdc Cooling valve 6 Typical applications Schematic Wiring Settings 2 pipe system cooling and/or heating: VT7300A5x00(x), VT7300C5x00(x) & VT7305C5x00(x) On / Off N.C. actuator Mandatory 24 Vac fan relays • Pipe no = 2 pipes High Normally Closed On/Off Fan-H • CntrltTyp = On/Off Valve Cooling and/or Heating Fan-M Med • Fan Menu = 0 (L-M-H) • FL time = as per actuator Fan-L 3 Speed fan Low UI3 COS If cooling only set:: • SeqOpera = 0 Cooling only 24 V~ Com 24 V~ Hot Room Temperature Control Thermostat BO2 N.C. If heating only set:: • SeqOpera = 1 Heating only Optional supply water temperature sensor If heat / cool auto-changeover with a local water temperature sensor set: • SeqOpera = 0 Cooling only • UI3 = COS 2 pipe system cooling and/or heating: VT7300C5x00(x) & VT7305C5x00(x) Floating actuator Mandatory 24 Vac fan relays • Pipe no = 2 pipes Modulating Floating High Valve Cooling and/or Heating • CntrltTyp = Floating Fan-H • Fan Menu = 0 (L-M-H) Fan-M Med 3 Speed fan • FL time = as per actuator Fan-L Low UI3 COS If cooling only set:: • SeqOpera = 0 Cooling only 24 V~ Com 24 V~ Hot Room Temperature Control Thermostat If heating only set:: • SeqOpera = 1 Heating only BO1 Open BO2 Close Optional supply water temperature sensor If heat / cool auto-changeover with a local water temperature sensor set: • SeqOpera = 0 Cooling only • UI3 = COS 2 pipe system cooling and/or heating: VT7300F5x00(x) & VT7305F5x00(x) Analog actuator Mandatory 24 Vac fan relays • Pipe no = 2 pipes Modulating Analog High Valve Cooling and/or Heating Fan-H • Fan Menu = 0 (L-M-H) • RA/DA = as per actuator Fan-M Med 3 Speed fan Fan-L Low UI3 COS 0 V~ Com 24 V~ Hot Room Temperature Control Thermostat If cooling only set:: • SeqOpera = 0 Cooling only If heating only set:: • SeqOpera = 1 Heating only AO1 0 to 10 Vdc Optional supply water temperature sensor If heat / cool auto-changeover with a local water temperature sensor set: • SeqOpera = 0 Cooling only • UI3 = COS Schematic Wiring Settings 4 pipe system cooling and heating: VT7300C5x00(x) & VT7305C5x00(x) On / Off N.C. actuators 24 Vac fan relays Mandatory Normally Closed On/Off • Pipe no = 4 pipes High Valve Cooling and Heating Fan-H • CntrltTyp = On/Off Fan-M Med • Fan Menu = 0 (L-M-H) 3 Speed fan Fan-L • FL time = as per actuator Low • SeqOpera = 4 Cool/Heat 24 V~ Com 24 V~ Hot BO2 Close Room Temperature Control Thermostat BO4 Close Heating Cooling 4 pipe system cooling and heating: VT7300C5x00(x) & VT7305C5x00(x) Floating actuators 24 Vac fan relays Mandatory Modulating Floating Valve Cooling and Heating • Pipe no = 4 pipes High Fan-H • CntrltTyp = Floating Fan-M Med 3 Speed fan • Fan Menu = 0 (L-M-H) Fan-L • FL time = as per actuator Low • SeqOpera = 4 Cool/Heat 24 V~ Com 24 V~ Hot Room Temperature Control Thermostat BO1 Open BO2 Close BO3 Open BO4 Close Heating Cooling 4 pipe system cooling and heating: VT7300F5x00(x) & VT7305F5x00(x) Analog actuators Mandatory 24 Vac fan relays Modulating Analog • Pipe no = 4 pipes Valve Cooling and Heating High Fan-H • Fan Menu = 0 (L-M-H) Fan-M Med • RA/DA = as per actuator 3 Speed fan Fan-L • SeqOpera = 4 Cool/Heat Low 24 V~ Com 24 V~ Hot Room Temperature Control Thermostat AO1 AO2 0 t o 10 Vd c Heating 0 t o 10 Vd c Cooling 2 pipe system cooling or heating with reheat: VT7300C5x00(x) & VT7305C5x00(x) Floating actuator Mandatory Modulating Floating BO5 • Pipe no = 2 pipes Valve Cooling and/or Heating BO5 • CntrltTyp = Floating High Fan-H • Fan Menu = 0 (L-M-H) 3 Speed fan Fan-M Med • FL time = as per actuator Fan-L Electric • SeqOpera = 2 Cool/Reheat Low UI3 COS Reheat • UI3 = COS 24 Vac fan relays 24 V~ Com Room Temperature Control Thermostat 24 V~ Hot BO1 Open BO2 Close Optional supply water temperature sensor 8 Remote sensor accessories Model no. S3010W1000 S3020W1000 S2060A1000 S2000D1000 Description Wall mounted temperature sensor Wall mounted temperature sensor with override button and occupancy status LED Averaging temperature sensor Duct mounted temperature sensor Remote mount temperature sensors use 10K type 2 NTC thermistors. Features: • Each sensor can be configured for various averaging combinations • Optional occupancy led • Optional override key FIG.8 – S3020W1000 WALL MOUNTED SENSOR Wiring example of single remote room sensor: VT7300 Series Thermostat S3010W1000 S3020W1000 Remote wiring 1 sensor Remote wiring 1 sensor S2=On, S3=On S2=On, S3=On Scom Scom RS RS BO 5 Aux 24 Vac Com Scom OR RS ON Dip switch setting for: 1 sensor DI BI 2 1 2 S2-1 = ON S2-2 = ON Wiring examples of 2 remote room sensors for averaging applications: VT7300 Series Thermostat 1 x S3010W1000 and 1 x S3020W1000 Remote wiring 2 sensors S1=On, S2=Off VT7300 Series Thermostat Scom RS BO 5 Scom Scom Scom RS RS RS Aux Scom BO 5 24 Vac Com 2 x S3020W1000 Remote wiring 2 sensors S2=On, S3=Off RS Aux Aux 24 Vac Com DI BI 2 Scom RS DI DI BI 2 Notes for averaging applications: VT7300 Series Thermostat Scom RS 2 x S3010W1000 Remote wiring 2 sensors S2=On, S3=Off Scom Scom RS RS • • • S3010W1000 and S3020W1000 can be mixed matched. S3010W1000 and S3020W1000 are to be wired in parallel. Respect the dip switch setting in each remote sensor. Dip switch setting for: 2 sensors ON 1 2 S2-1 = OFF S2-2 = ON Wiring examples of 3 remote room sensors for averaging applications: VT7300 Series Thermostat Scom RS BO 5 24 Vac Com 2x S3010W1000 and 1 x S3020W1000 Remote wiring 3 sensors S2=Off, S3=Off VT7300 Series Thermostat Scom Scom Scom Scom RS RS RS RS 3x S3010W1000 Remote wiring 3 sensors S2=Off, S3=Off Scom Scom Scom RS RS RS Aux Dip switch setting for: 3 sensors DI BI 2 Temperature vs resistance chart for 10 Kohm NTC thermistor (R25°C = 10KΩ±3%, B25/85°C = 3975K±1.5%) ºC -40 -35 -30 -25 ºF -40 -31 -22 -13 Kohm 324.3197 234.4009 171.3474 126.6109 ºC -20 -15 -10 -5 ºF -4 14 23 Kohm 94.5149 71.2430 54.1988 41.5956 ºC 10 15 ºF 32 41 50 59 Kohm 32.1910 25.1119 19.7390 15.6286 ºC 20 25 30 35 ºF Kohm 68 12.4601 77 10.0000 86 8.0694 95 6.5499 ºC 40 45 50 55 ºF 104 113 122 131 Kohm 5.3467 4.3881 3.6202 3.0016 ON 1 2 S2-1 = OFF S2-2 = OFF 9 Programming and status display instructions Status display The thermostat features a two-line, eight-character display. There is a low level backlight level that is always active and can only be seen at night. When left unattended, the thermostat has an auto scrolling display that shows the actual status of the system. There is an option in the configuration menu to lockout the scrolling display and to only present the room temperature and conditional outdoor temperature to the user. With this option enabled, no local status is given of mode, occupancy and relative humidity. Each item is scrolled one by one with the back lighting in low level mode. Pressing any key will cause the back light to come on to high level. When left unattended for 10 seconds after changes are made, the display will resume automatic status display scrolling. To turn on the back light to high level, press any key on the front panel. The back lit display will return to low level when the thermostat is left unattended for 45 seconds Sequence of auto-scroll status display: Room & Humidity System Mode Schedule Status Outdoor Temperature Alarms x.x °C or °F XX % RH Sys mode Auto Occupied Outdoor x.x °C or°F Service If humidity display enabled Sys mode Cool Stand-By Network value only Filter RoomTemp x.x °C or °F Sys mode heat Unoccup If humidity display is not enabled Sys mode off Override Window % RH display is conditional to: (Humidity display is model and configuration dependent) • Model with RH sensor built in • Display function can be enabled with RH display parameter. Displayed range is 10 to 90 % RH Outdoor air temperature • Display is only enabled when outdoor air temperature network variable is received. Occupancy Status • Occupied, Stand-By, Unoccupied and Override status are displayed on the scrolling display. Alarms • If alarms are detected, they will automatically be displayed at the end of the status display scroll. • During an alarm message display, the backlit screen will light up at the same time as the message and shut off during the rest of the status display. • Two alarms maximum can appear at any given time. The priority for the alarms is as follows: Service Filter Window Indicates that there is a service alarm as per one of the programmable binary input ( BI2 ) Indicates that the filters are dirty as per one of the programmable binary input ( BI2 ) Indicates that the outside window or door is opened and that the thermostat has cancelled any cooling or heating action ( BI1 ) Three status LED’s on the thermostat cover are used to indicate the status of the fan ( any speed ), a call for heat, or a call for cooling. Fan coil models • When any of the fan speeds are ON, the FAN LED will illuminate. • When heating & reheat is ON, the HEAT LED will illuminate. • When cooling is ON, the COOL LED will illuminate. Fig.11 – Hotel models °C/°F Fig. 12 Commercial models with Override Installer configuration parameter menu Configuration can be done through the network or locally at the thermostat. • To enter configuration, press and hold the middle button (°C/°F or Override) for 8 seconds • Press the same middle button repetitively to scroll between all the available parameters • Use the up and down key to change the parameter to the desired value. • To acknowledge and save the new value, press the middle button again. • The next listed parameter is now displayed 10 Configuration interface Re-starts the configuration parameter list at the beginning Fan Enters the configuration mode. Press and hold for 8 seconds °C/°F Pressing repetitively will scroll all available parameters one by one Override Adjust / rotate parameter value down Down Adjust / rotate parameter value up Up User interface • Unoccupied mode Override An Override can be made on commercial models during an Unoccupied period. If the Override option is enabled in the lockout configuration pressing the middle override button will resume occupied setpoints for a time specified by parameter ToccTime • • Keypad interface Is used to toggle between the different system mode available as per sequence and menu selected Pressing repetitively the button will toggle between all the available modes System Available menus are dependent on selected sequence of operation Is used to toggle between the different fan mode available as per sequence and menu selected Pressing repetitively the button will toggle between all the available modes Fan Available menus are dependent on selected sequence of operation and menu selected for Fan Middle key is °C/°F • °C / °F for Hotel models Override • Override for commercial models Adjust the setpoints down In cooling mode only the cooling setpoint displayed, Down In heating mode only the heating setpoint displayed In auto mode, (See below) Adjust the setpoints up In cooling mode only the cooling setpoint displayed, Up In heating mode only the heating setpoint displayed In auto mode, (See below) 1. Any setpoint change can be permanent or temporary based on configuration parameter (Setpoint Type) 2. Any setpoint written through the network, will be permanent and cancel any active temporary setpoints 3. Lockouts of access to certain functions is made with configuration parameter (lockout) Occupied setpoint adjustments Cooling mode Heating mode Off mode Auto Mode • Setpoint presented to user is the setpoint from the last action taken by the thermostat or the one currently in use. • If the other setpoint is the one desired, then the MODE button is used to toggle between the current displayed one and the other. Cool XX.X °F or °C Heat XX.X °F or °C No access to setpoint Cool XX.X °F or °C or Heat XX.X °F or °C Toggle to ( Heat or Cool )with MODE button • • Heat/Cool setpoint toggle with MODE button to be active only in AUTO mode. If cooling, heating or off mode is active, function is disabled • Unoccupied and Stand-By setpoints adjustments Setting the stand-by and unoccupied setpoints is done through the network or through configuration setup only. • 11 Mode button menu sequence. Modes presented to the user are dependent on sequence of operation selected Default mode is in bold when sequence of operation parameter is changed * Auto mode menu can be disabled with (AutoMode) parameter Sequence selected 0 = Cooling only 1 = Heating only 2 = Cooling With Reheat 3 = Heating With Reheat 4 = Cooling / Heating 4 pipes 5 = Cooling / Heating 4 pipes with Reheat Mode Menu Off - Cool Off - Heat Off – Auto *– Heat – Cool Off - Heat Off – Auto *– Heat – Cool Off – Auto *– Heat – Cool * Auto. The Auto mode can be disabled from the menu with the (AutoMode) parameter • Available fan button menu sequences. Fan button menu configuration 0 Low-Med-High 1 Low-High 2 Low-Med-High-Auto 3 Low-High-Auto 4 On-Auto Menu presented are dependent on model used and sequence of operation selected 3 Speed configuration using 3 fan relays ( L-M-H ) 2 Speed configuration using 2 fan relays ( L-H ) 3 Speed configuration with Auto fan speed mode using 3 fan relays ( L-M-H ) 2 Speed configuration with Auto fan speed mode using 2 fan relays ( L-H ) Single Speed configuration. Auto is for Fan on demand / On is On all the time Default value when sequence toggled High High High High Auto Auto speed fan mode is also offered in heating mode applications; it will not however have any effect on dehumidification. It will be strictly for noise comfort issues Configuration parameters Default value Com Addr Thermostat networking address Default value = 4 Range is: 0 to 254 PAN ID Personal Area Network Identification Default value = 0 Range is: 0 to 500 Significance and adjustments Conditional parameter to BACnet MS-TP models (VT730xX1000B) Conditional parameter to Wireless models (VT730xX1000W) This parameter will only appear when a BACnet or wireless network adapter is present. If the thermostat is installed as a stand-alone unit or with an Echelon adapter, this parameter will not be used or displayed • For BACnet MS-TP models valid range to use is from 1 to 127 • For wireless models valid range is 0 to 254 with a maximum of 30 thermostat per VGG Conditional parameter to Wireless models (VT730xX1000W) This parameter will only appear when a wireless network adapter is present. If the thermostat is installed as a stand-alone unit or with a BACnet or Echelon adapter, this parameter will not be used or displayed This parameter (Personal Area Network Identification) is used to link specific thermostats to a single specific Viconics wireless gateway ( VWG ) For every thermostat reporting to a gateway ( maximum of 30 thermostats per gateway ), be sure you set the SAME PAN ID value both at the gateway and the thermostat(s). The default value of 0 is NOT a valid PAN ID. The valid range of available PAN ID is from 1 to 500 Channel Channel selection Default value = 10 Range is: 10 to 26 Conditional parameter to Wireless models (VT73x0X1000W) This parameter will only appear when a wireless network adapter is present. If the thermostat is installed as a stand-alone unit or with a BACnet or Echelon adapter, this parameter will not be used or displayed This parameter (Channel) is used to link specific thermostats to specific Viconics wireless gateway(s) ( VWG ) For every thermostat reporting to a gateway ( maximum of 30 thermostats per gateway ), be sure you set the SAME channel value both at the gateway and the thermostat(s). Viconics recommends using only the 2 last channels ( 25-2575MHz and 262580MHz ) The default value of 10 is NOT a valid channel. The valid range of available channel is from 11 to 26 12 Get From Thermostat Get From another device configuration utility Default value = 0 Range is: 0 to 254 BI1 Binary input no.1 configuration Default value = None Conditional parameter to Wireless models (VT730xX1000W) This parameter / function is not currently supported by the wireless thermostats. (None): No function will be associated with the input (Rem NSB): remote NSB timer clock input. The scheduling will now be set as per the binary input. It provides low cost setback operation via a dry contact Contact opened = Occupied Contact closed = Unoccupied (Motion NO) or (Motion NC): Advanced PIR occupancy functions using a Normally Open (NO) or Normally Closed (NC) remote PIR motion sensor. Occupancy mode is now set as per applied PIR function and configuration. Application information and examples are available on document: APP-PIRGuide-Exx. This document will provide the installers and system designers with detailed examples on applications, parameter configuration information, sequence of operation, troubleshooting and diagnostic help required for the proper usage of the PIR accessory covers (Window) EMS: Forces the system to disable any current heating or cooling action by the thermostat. The mode stays the same and the current setpoints are the same Occupied setpoints. Only the outputs are disabled. There is a Door/Window alarm displayed on the thermostat to indicate to the local tenant that the door/window needs to be closed for cooling or heating to resume. BI2 Binary input no.2 configuration Default value = None * these settings will disable the local override function on the thermostat. (None): No function will be associated with the input (Door Dry) Door contact & Motion detector: This configuration is only functional if binary input #1 is set to Motion NO or Motion NC or a PIR accessory cover is used. With this sequence enabled, the occupancy is now dictated through those 2 inputs. Any motion detected will set the zone to occupied status. The zone will remain permanently in occupied mode until the door contact switch opens momentarily. The thermostat will then go in stand-by mode. If more movements are detected, the occupied mode will resume. While the door is opened, any movements detected by the remote PIR sensor or the PIR accessory cover will be ignored. Use a Normally Closed contact switching device. Contact opened = Door opened Contact closed = Door closed (RemOVR): temporary occupancy remote override contact. This function disables the central button override function on the thermostat. The override function is now controlled by a manual remote momentarily closed contact. When configured in this mode, the input operates in a toggle mode. It is now possible to toggle between unoccupied & occupied setpoints for the amount of time set by parameter (TOccTime) temporary occupancy time. (Filter): a backlit flashing Filter alarm will be displayed on the thermostat LCD screen when the input is energized. It can be tied to a differential pressure switch that monitor filters Contact opened = No alarm Contact closed = Alarm displayed (Service): a backlit flashing Service alarm will be displayed on the thermostat LCD screen when the input is energized. It can be tied in to the AC unit control card, which provides an alarm in case of malfunction. Contact opened = No alarm Contact closed = Alarm displayed 13 (None): No function will be associated with the input UI3 Universal input no.3 configuration (COC/NH) Change over dry contact. Normally Heat: Used for hot / cold water or Default value = None air change over switching in 2 pipe systems. Contact closed = Cold water or air present Contact opened = Hot water or air present Only used and valid if system is setup as 2 pipes. Parameter ( Pipe No ) set as 2 pipes. (COC/NC) Change over dry contact. Normally Cool: Used for hot / cold water or air change over switching in 2 pipe systems. Contact closed = Hot water present Contact opened = Cold water present Only used and valid if system is setup as 2 pipes. Parameter (Pipe No ) set as 2 pipes. (COS) Change over analog sensor: Used for hot / cold water or air change over switching in 2 pipe systems. Only used and valid if system is setup as 2 pipes. Parameter (Pipe No ) set as 2 pipes. If water temperature is > 78 °F = Hot water present If water temperature is < 75 °F = Cold water present (SS) Supply air sensor monitoring: Used for supply air temperature monitoring. Only used for network reporting of the supply air temperature. Has no internal function in the thermostat. Removes the scrolling display and only present the room temperature/humidity to the user. MenuScro With this option enabled, no status is given of mode, schedule and outdoor temperature. Menu scroll On = Scroll active Default value = On = Scroll active Off = Scroll not active Enables Auto function for the mode button AutoMode For sequences 2, 4 & 5 only Enables Auto menu for Mode On = Auto active (Off-Cool-Heat-Auto) button Off = auto not active (Off-Cool-Heat) Default value = Off °F for Fahrenheit scale C or F Sets scale of the thermostat °C for Celsius scale Default value = °F On hotel models, this sets the default value when the thermostat powers up RH models only %RH disp Enables the display of humidity below the room temperature on the display Local %RH Display ON = Display %RH Default value = OFF Models with Humidity sensor only OFF = No display of %RH VT735xX5x00(x) models only Lockout Keypad lockout levels Default value = 0 No lock Level Occupied temperature setpoints Yes access Yes access Yes access Yes access No access No access Pipe No System type installation Number of pipes Default is: 4.0 Pipes System mode setting Fan mode setting Unoccupied Override Yes access Yes access No access No access No access No access Yes access Yes access No access No access No access No access Yes access No access Yes access No access Yes access No access Defines the type of system installed 2.0 Pipes, will limit the number of sequences of operation available from 0 to 3 Will enable heat/cool operation from the same output ( refer to wiring diagram ) 4.0 Pipes, can access all the sequences of operation from 0 to 5 Will enable heat/cool operation from different output ( refer to wiring diagram ) 14 CntrlTyp Control type for Triac models Default is: Floating Defines the type of control output for the type of valves installed VT7350C10xx, VT7300C10xx, VT7355C10xx and VT7305C10xx only On/Off is for normally opened or normally closed 24 Vac 2 position valves Floating is for modulating 3 wires control of 24 Vac floating valves SeqOpera Sequence of operation Default is: Sequence #1 0 = Cooling Only 1 = Heating only 2 = Cooling With Reheat 3 = Heating With Reheat 4 = Cooling / Heating 4 pipes 5 = Cooling / Heating 4 pipes with Reheat Fan Menu Mode button menu configuration Default is: Menu #4 0 = Low-Med-High 1 = Low-High 2 = Low-Med-High-Auto 3 = Low-High-Auto 4 = On-Auto DHumiLCK Dehumidification lockout VT735xX5x00(x) models only Default value: On = Authorized %RH set Dehumidification setpoint Default is 50 % RH DehuHyst Dehumidification Hysterisys Default is 5 % RH DehuCool Maximum Dehumidification Cooling output Default is 100 % St-By TM Stand-by Timer value Default 0.5 hours Unocc TM Unoccupied Timer value Default 0.0 hours St-By HT Stand-by heating setpoint Default value = 69 °F System = 2 Pipes System = 4 Pipes Yes access Yes access Yes access Yes access No access No access Yes access Yes access Yes access Yes access Yes access Yes access For single output applications, the system access is also limited if UI3 is configured for local changeover COS, COC/NC or COC/NC. The system mode available for the local configuration or network write is then limited by the current water temperature detected by the UI3. Menu presented are dependent on model used and sequence of operation selected 3 Speed configuration using 3 fan relays ( L-M-H ) 2 Speed configuration using 2 fan relays ( L-H ) 3 Speed configuration with Auto fan speed mode using 3 fan relays ( L-M-H ) 2 Speed configuration with Auto fan speed mode using 2 fan relays ( L-H ) Single Speed configuration. Auto is for Fan on demand / On is On all the time Typically toggled through the network. This variable enables or disables dehumidification based on central network requirements from the BAS front end On = Dehumidification Authorized Off = Dehumidification Not Authorized Used only if dehumidification sequence is enabled: Range is: 30-95% RH VT735xX5x00(x) models only Humidity control hysterisys. Used only if dehumidification sequence is enabled: Range is: 2 to 20% RH VT735xX5x00(x) models only Maximum cooling valve position when dehumidification is enabled. This can be used to balance smaller reheat loads installed in regards to the capacity of the cooling coil. Range is: 20 to 100 % VT735xX5x00(x) models only Time delay between the moment where the PIR cover detected the last movement in the area and the time which the thermostat stand-by mode and setpoints become active. Range is: 0.5 to 24.0 hours in 0.5hr increments Time delay between the moment where the thermostat toggles to stand-by mode and the time which the thermostat unoccupied mode and setpoints become active. The factory value or 0.0 hours: Setting this parameter to its default value of 0.0 hours disables the unoccupied timer. This prevents the thermostat to drift from stand-by mode to unoccupied mode when PIR functions are used Range is: 0.0 to 24.0 hours in 0.5hr increments The value of this parameter should reside between the occupied and unoccupied heating setpoints and make sure that the difference between the stand-by and occupied value can be recovered in a timely fashion when movement is detected in the zone. Stand-by heating setpoint range is: 40 to 90 °F ( 4.5 to 32.0 °C ) 15 St-By CL Stand-by cooling setpoint limit Default value = 78 °F Unocc HT Unoccupied heating setpoint Default value = 62 °F Unocc CL Unoccupied cooling setpoint limit Default value = 80 °F heat max Maximum heating setpoint limit Default value = 90 °F ( 32 °C ) cool min Minimum cooling setpoint limit Default value = 54 °F ( 12 °C ) Set Type Temporary setpoint enable Default is : Permnent The value of this parameter should reside between the occupied and unoccupied cooling setpoints and make sure that the difference between the stand-by and occupied value can be recovered in a timely fashion when movement is detected in the zone. Stand-by cooling setpoint range is: 54 to 100 °F ( 12.0 to 37.5 °C ) Unoccupied heating setpoint range is: 40 to 90 °F ( 4.5 to 32.0 °C ) Unoccupied cooling setpoint range is: 54 to 100 °F ( 12.0 to 37.5 °C ) Maximum occupied & unoccupied heating setpoint adjustment. Heating setpoint range is: 40 to 90 °F ( 4.5 to 32.0 °C ) Minimum occupied & unoccupied cooling setpoint adjustment. Cooling setpoint range is: 54 to 100 °F ( 12.0 to 37.5 °C ) Temporar: (temporary) Local changes to the heating or cooling setpoints by the user are temporary. They will remain effective for the duration specified by ToccTime. Setpoints will revert back to their default value after internal timer ToccTime expires. Enables temporary setpoints To change setpoints permanently, revert to No this variable or write setpoints feature to any change of through the network. Any setpoints written through the network will be permanent occupied or unoccupied setpoint. ones and saved to EEPROM. Permnent: (permanent) Any change of occupied or unoccupied setpoints through the keypad by the user are permanent and saved to & EEPROM TOccTime Temporary occupancy time with occupied mode setpoints when override function is enabled Temporary occupancy time Default value = 2 hours When the thermostat is in unoccupied mode, function is enabled with either the menu or UI2 configured as remote override input. Range is: 0,1, 2, 3, 4, 5, 6, 7, 8, 9, 10, & up to 24 hours deadband Minimum deadband value between the heating and cooling setpoints. If modified, it will be applied only when any of the setpoints are modified. Minimum deadband Default value = 2.0 °F ( 1.0 °C ) Range is: 2, 3, 4 or 5 °F, 1.0 °F increments ( 1.0 to 2.5 °C, 0.5 °C increments ) cal RS Offset that can be added/subtracted to actual displayed room temperature Room temperature sensor Range is: ± 5.0 °F, 1.0 °F increments ( ± 2.5 °C, 0.5 °C increments ) calibration Default value = 0.0 °F or °C cal RH Offset that can be added/subtracted to actual displayed humidity by ± 15.0 %RH. Humidity sensor calibration Range is : ± 15.0 %RH Default value = 0 %RH 16 aux cont Auxiliary contact function & configuration Default value = 0 Not Used 0 Aux contact function used for reheat IF SEQUENCE IS SET TO REHEAT THROUGH NETWORK OR LOCAL, Ignore this parameter The output will directly follow the occupancy of the thermostat 1 Auxiliary NO, Occ or St-By = Contact Closed / Unoccupied = Contact Opened 2 Auxiliary NC, Occ or St-By = Contact Opened / Unoccupied = Contact Closed Output to follow directly main occupancy and Fan on command Typically used for 2 position fresh air damper applications. 3 Auxiliary NO, Occ or St-By & Fan On = Contact Closed / Unoccupied & Fan On or Off = Contact Opened 4 Auxiliary NC, Occ or St-By & Fan On = Contact Opened / Unoccupied & Fan On or Off = Contact Closed FL time For floating models VT73xxC5x00(x) only Default value: 1.5 minutes cph On/Off devices cycles per hour For On/Off models & sequences VT73xxC5x00(x) only Default value = 4 C.P.H. RA/DA For Analog models VT73xxF5x00(x) only Default value: DA signal Reheat Default value: 0 = 15 minute UI3 dis Display UI3 value. Output to follow secondary network occupancy command 5 Auxiliary On/Off Control through auxiliary network command. The output can be commanded through the network for any required auxiliary functions through a separate & dedicated network variable. Floating actuator timing Maximum stroke time of floating valve actuator. Range is: 0.5 to 9.0 minutes in 0.5 minutes increment Will set the maximum number cycles per hour under normal control operation. It represents the maximum number of cycles that the equipment will turn ON and OFF in one hour. Note that a higher C.P.H will represent a higher accuracy of control at the expense of wearing mechanical components faster. Range is: 3, 4, 5, 6,7 & 8 C.P.H. Reverse acting or Direct acting signal for Analog output signals DA = Direct acting, 0 to 100 % = 0 to 10 Vdc RA = Reverse acting, 0 to 100 % = 10 to 0 Vdc Sets the reheat output time base Valid only if reheat sequences are enabled 0 = 15 minutes 1 = 10 seconds for Solid state relays Used as diagnostic / service help to troubleshoot and diagnose sensor operation Supply or change over temperature when UI3 is configured as an analog input ( SS or COS ) 17 Specifications Thermostat power requirements: Operating conditions: 19-30 Vac 50 or 60 Hz; 2 VA Class 2 0 °C to 50 °C ( 32 °F to 122 °F ) 0% to 95% R.H. non-condensing Storage conditions: -30 °C to 50 °C ( -22 °F to 122 °F ) 0% to 95% R.H. non-condensing Temperature sensor: Local 10 K NTC thermistor Temperate sensor resolution: ± 0.1 °C ( ± 0.2 °F ) Temperature control accuracy: ± 0.5 ° C ( ± 0.9 °F ) @ 21 °C ( 70 °F ) typical calibrated Humidity sensor and calibration: Single point calibrated bulk polymer type sensor Humidity sensor precision: Reading range from 10-90 % R.H. non-condensing 10 to 20% precision is 10% 20% to 80% precision is 5% 80% to 90% precision is 10% Humidity sensor stability Less than 1.0 % yearly (typical drift) Dehumidification setpoint range: 30% to 95% R.H. Occ, Stand-By and Unocc cooling setpoint range: 12.0 to 37.5 °C ( 54 to 100 °F ) Occ, Stand-By and Unocc heating setpoint range: 4.5 °C to 32 °C ( 40 °F to 90 °F ) Room and outdoor air temperature display range -40 °C to 50 °C ( -40 °F to 122 °F ) Proportional band for room temperature control: Cooling & Heating: 1.8°C ( 3.2°F ) Binary inputs: Dry contact across terminal BI1, BI2 & UI3 to Scom Contact output rating: Fan relay output: 30 Vac, 1 Amp. Maximum, 3 Amp. in-rush Valve triac output: 30 Vac, 1 Amp. Maximum, 3 Amp. in-rush Valve analog: 0 to 10 Vdc into 2KΩ resistance min. Wire gauge 18 gauge maximum, 22 gauge recommended Dimensions: 4.94” x 3.38” x 1.13” Approximate shipping weight: 0.75 lb ( 0.34 kg ) Agency Approvals all models: UL: UL 873 (US) and CSA C22.2 No. 24 (Canada), File E27734 with CCN XAPX (US) and XAPX7 (Canada) Industry Canada: ICES-003 (Canada) Agency Approvals Stand-Alone, BACnet & LON models FCC: Compliant to CFR 47, Part 15, Subpart B, Class A (US) CE: EMC Directive 89/336/EEC (Europe Union) C-Tick: AS/NZS CISPR 22 Compliant (Australia / New Zealand) Supplier Code Number N10696 Agency Approvals Wireless models FCC: Compliant to: Part 15, Subpart C THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Drawing & Dimensions Important Notice 4.94" [125 mm] 3.38" [86 mm] 1.13" [29 mm] Fig.13 – Thermostat dimensions All VT7300 series controls are for use as operating controls only and are not safety devices. These instruments have undergone rigorous tests and verifications prior to shipment to ensure proper and reliable operation in the field. Whenever a control failure could lead to personal injury and/or loss of property, it becomes the responsibility of the user / installer / electrical system designer to incorporate safety devices ( such as relays, flow switch, thermal protections, etc…) and/or alarm system to protect the entire system against such catastrophic failures. Tampering of the devices or miss application of the device will void warranty.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Company : Johnson Controls Inc Source Modified : D:20080617025854 Creator Tool : Acrobat PDFMaker 7.0.7 for Word Modify Date : 2008:06:16 23:00:57-04:00 Create Date : 2008:06:16 22:59:43-04:00 Metadata Date : 2008:06:16 23:00:57-04:00 Document ID : uuid:37fd4c19-d40e-44fc-b2b8-7521aaef3d6b Instance ID : uuid:d2687061-7968-4c11-9b10-79432f62b55f Version ID : 2 Format : application/pdf Title : TE-6700 Series 2nd Generation Temperature Elements Product Bulletin Creator : Jan Kunze Subject : Headline : Page Count : 17 Page Layout : OneColumn Author : Jan KunzeEXIF Metadata provided by EXIF.tools