User Manual
K P-2 5 0 PG2 Advanced Two-Way Keypad User’s Guide T a ble of Cont e nt s 1. Introduction ................................................................................................................................................................. 3 2. Additional System Features ........................................................................................................................................ 3 Partitioning .............................................................................................................................................................. 3 Screen Saver .......................................................................................................................................................... 3 Proximity Tags ........................................................................................................................................................ 3 Users and Codes .................................................................................................................................................... 3 Speech & Sound Cont. Push-buttons ..................................................................................................................... 3 Voice ON/OFF ........................................................................................................................................................ 4 Recording a Message ............................................................................................................................................. 4 Message Playback.................................................................................................................................................. 5 3. Arming and Disarming the System ............................................................................................................................. 6 Basic Arming and Disarming................................................................................................................................... 6 Special Arming & Disarming Options ...................................................................................................................... 7 Initiating Alarms .................................................................................................................................................... 10 4. System Status and Indications ................................................................................................................................. 13 LCD Display and General Audible Indicators ........................................................................................................ 13 Arming Indications ................................................................................................................................................ 13 General Indications ............................................................................................................................................... 14 Alarm Indication Siren........................................................................................................................................... 15 5. Reviewing Troubles and Alarm Memory ................................................................................................................... 16 Alarm & Tamper Memory Indication ..................................................................................................................... 16 Clearing the Memory Indication ............................................................................................................................ 16 Troubles ................................................................................................................................................................ 16 GSM/GPRS Status Indications ............................................................................................................................. 17 Trouble Indications ............................................................................................................................................... 18 6. System Configuration ............................................................................................................................................... 19 A.1 Entering the User Settings Menu & Selecting a Setting Option ...................................................................... 19 A.2 Returning to the Previous Step or Exiting the USER SETTINGS Menu ......................................................... 21 A.3 Buttons used for Navigation & Setting ............................................................................................................ 22 B.1 Setting the Zone Bypass Scheme .................................................................................................................. 22 B.2 Reviewing the Zone Bypass Scheme ............................................................................................................. 24 B.3 Recalling the Zone Bypass Scheme............................................................................................................... 24 B.4 Programming User Codes .............................................................................................................................. 25 B.5 Programming the Duress Code ...................................................................................................................... 27 B.6 Add / Delete Proximity Tags ........................................................................................................................... 28 B.7 Add / Delete Keyfob Transmitters................................................................................................................... 30 B.8 Setting the Time & Time Format..................................................................................................................... 33 B.9 Setting the Date & Date Format ..................................................................................................................... 35 B.10 Enabling / Disabling Auto-Arming ................................................................................................................. 36 B.11 Setting the Auto-Arming Time ...................................................................................................................... 36 B.12 Programming Private Phone and SMS Reporting ........................................................................................ 37 B.13 Enabling / Disabling the Squawk Option ...................................................................................................... 42 D-304269 KP-250 PG2 User’s Guide B.14 Programming the Scheduler ......................................................................................................................... 43 B.15 Enabling / Disabling Voice Option ................................................................................................................ 45 B.16 Adjusting the Volume of the Control Panel or External Box .......................................................................... 46 B.17 Serial Number............................................................................................................................................... 47 7. Advanced Features................................................................................................................................................... 48 Control Options and Pushbuttons ......................................................................................................................... 48 Automatic ON/OFF Control ................................................................................................................................... 49 8. Periodic Test by User Code ...................................................................................................................................... 50 Periodic Test per Partition ..................................................................................................................................... 53 9. Maintenance ............................................................................................................................................................. 55 Replacing Wireless Devices Batteries .................................................................................................................. 55 Accessing 24-Hour Zones ..................................................................................................................................... 55 Event Log by User Code ....................................................................................................................................... 55 Exiting the Event Log ............................................................................................................................................ 56 APPENDIX A: Specifications ........................................................................................................................................ 57 APPENDIX B: Partitioning ............................................................................................................................................ 57 B1. Selecting a Partition ........................................................................................................................................ 57 B2. Arming / Disarming the System ...................................................................................................................... 57 B3. The Show Function......................................................................................................................................... 58 B4. Siren ............................................................................................................................................................... 58 B5. Partition Status display ................................................................................................................................... 58 B6. Common Areas............................................................................................................................................... 58 APPENDIX C: Glossary ................................................................................................................................................ 60 APPENDIX D: Compliance with Standards .................................................................................................................. 63 D-304269 KP-250 PG2 User’s Guide 1 . I nt roduc t ion 1 . I nt roduc t ion KP-250 PG2 is a 2-way wireless PowerG keypad display device for use with the PowerMaster-10 G2 / PowerMaster-30 G2 / PowerMaster-33 G2 control panel (version 18 and higher). Up to 10 KP-250 PG2 keypads can be enrolled in the PowerMaster system. The PowerMaster-10 G2 / PowerMaster-30 G2 / PowerMaster-33 G2 is a highly advanced wireless alarm control panel produced by Visonic Ltd. 2 . Addit iona l Syst e m Fe a t ure s Pa rt it ioning Partitioning allows you to divide the system into three independently controllable areas with different users assigned to each partition whereby each user can arm the partition to which they are assigned. For detailed information on Partitioning, see APPENDIX B. Sc re e n Sa ve r For security reasons, it is sometimes required to hide the status indication (LCD and LED display) on the KP-250 PG2 keypad from a potential intruder. When operated by AC power and the Screen Saver option is enabled by the installer, then if no key is pressed for more than 30 seconds, the screen saver will turn on and the LEDs will stop indicating any status. When operated by batteries and the Screen Saver option is enabled by the installer, then if no key is pressed for more than 10 seconds, the display will turn off and the LEDs will stop indicating any status. Pressing any key will resume the normal status display. Pressing the Fire, Emergency or Panic keys will also initiate the Fire, Emergency or Panic alarm. If configured by the installer for additional security, the system will ask you to enter your user code or to present your proximity tag before resuming the normal display. When partition is enabled, the installer can configure the system so that if no key is pressed during more than 30 seconds the date and time will appear on the display. Prox im it y T a gs Your system responds to valid proximity tags enrolled to the system. The proximity tag enables you to perform a variety of functions without entering a user code, for example, arming, disarming, reading the event log, etc. 1. Whenever the user code is required, you can simply present a valid proximity tag and perform the desired operation without the need to key-in your user code. - OR 2. When the system is disarmed and after presenting a valid proximity tag to the KP-250 PG2 keypad, the message "for AWAY" is displayed. Now you can press the button to immediately arm the system, or, press the button once / twice – the message “ for HOME” / “ for disarm” is displayed – and then press the button for HOME arming / disarming.1 Note: If you do not press the button (wait for 3 seconds), the system automatically arms AWAY and the display will read "ARMING AWAY PLEASE EXIT NOW". Presenting the proximity tag once again will DISARM the system. U se rs a nd Code s Security codes are used mainly to arm and disarm the system or to access information that is restricted only to authorized users (see Chapter 6, section B.4, Programming User Codes). Spe e c h & Sound Cont . Push-but t ons The sound and speech-related functions offered by the PowerMaster alarm system can be controlled by the KP-250 PG2 keypad, as detailed in the following list. In option 2, the KP-250 PG2 keypad will not operate (respond) if the KP-250 PG2 is assigned to two or more partitions. D-304269 KP-250 PG2 User’s Guide 2 . Addit iona l Syst e m Fe a t ure s Key Function Increases the loudness of KP-250 PG2 local audio indications Decreases the loudness of KP-250 PG2 local audio indications Enables / disables the loudspeaker1 Records a spoken message for other users of the alarm system Allows listening to a recorded message left by another user of the alarm system Enables / disables the KP-250 PG2 local chime function V oic e ON /OFF 2 Spoken announcements on the PowerMaster control panel can be switched on and off by alternate clicking of the <7> key on the KP-250 PG2 keypad, as shown below. RESULTING DISPLAY PRESS MUTE ON MUTE OFF HH:MM READY Note: The system will maintain the “MUTE OFF” state until subsequent selection of “MUTE ON’. Re c ording a M e ssa ge You can record a verbal message on the PowerMaster control panel, by the KP-250 PG2, for other users of the alarm system. Face the panel, press on the KP-250 PG2 keypad and keep it pressed. When the display reads TALK NOW, start talking. A progress indicator will be displayed that is incremented each time by 25%, as follows: 0%, 25%, 50%, 75%, 100%. ACTION TO RECORD A MESSAGE RESULTING DISPLAY TALK NOW (press and hold) Talk TALK NOW Stop talking Not applicable to PowerMaster-10 Refers to PowerMaster-30 G2 only ) 100% RECORDING ENDED D-304269 KP-250 PG2 User’s Guide 2 . Addit iona l Syst e m Fe a t ure s Once the progress indicator reaches 100%, RECORDING ENDED will be displayed. When you release the button, the display will revert to the normal status-displaying mode, but will also indicate that a message is waiting. For example: HH:MM READY MESSAGE Note: The message icon ( ) will also flash on the bottom of the display. M e ssa ge Pla yba c k Message playback is performed by the control panel. To listen to a message left by another user of the system: Click on the KP-250 PG2 keypad and listen. PLAY will be displayed and the message will be played back over the PowerMaster loudspeaker or external voice box. When the playback ends, the display will revert to the normal statusdisplaying mode. D-304269 KP-250 PG2 User’s Guide 3 . Arm ing a nd Disa rm ing t he Syst e m 3 . Arm ing a nd Disa rm ing t he Syst e m Ba sic Arm ing a nd Disa rm ing Following are a set of procedures for performing basic arming and disarming of the alarm system. Preparing to Arm Before arming, make sure that READY is displayed on the KP-250 PG2 keypad. HH:MM READY This indicates that all zones are secured and you may arm the system as desired. If at least one zone is open (disturbed) the display will read: HH:MM NOT READY This indicates that the system is not ready for arming and in most cases that one or more zones are not secured. However, it can also mean that an unresolved condition exists such as certain trouble conditions, jamming etc., depending on system configuration. To review the open zones click on the KP-250 PG2 keypad. The details and location of the first open zone detector (usually an open door or window sensor) will be displayed. To fix the open zone, locate the sensor and secure it (close the door or window) – see "device locator" below. Each click of on the KP-250 PG2 keypad will display another open zone or trouble indication. It is highly recommended to fix the open zone(s), thus restoring the system to the state of “ready to arm”. If you do not know how to do this, consult your installer. Note: To quit at any stage and to revert to the "READY" display, click on the KP-250 PG2 keypad. Device Locator: The PowerMaster system has a powerful device locator that helps you to identify open or troubled devices indicated on the LCD display. While the LCD displays an open or faulty device, the LED on the respective device flashes indicating "it's me". The "it's me" indication will appear on the device within max. 16 seconds and will last for as long as the LCD displays the device. Arming ‘AWAY' / ‘HOME' If the system is READY and/or Forced Arming is enabled proceed as shown below. For more information on Forced Arming, see "Forced Arming AWAY or HOME" below. If the system is NOT READY and Forced Arming is not permitted, review any open zone detectors to locate and secure them. If you want to arm using partitions, see "Partition Selection Process" and then proceed as shown below. If the user has changed the state of the system from a high security mode to a lower security mode i.e. from ARM to DISARM, or from AWAY to HOME, he will be prompted to enter the user code or to present his proximity tag thus bypassing the QUICK ARM option. PRESS RESULTING DISPLAY ARMING AWAY/HOME If Quick Arm is disabled PRESENT TAG OR ENTER CODE: PLEASE EXIT NOW Vacate the premises (ARM AWAY) OR (Exit delay) D-304269 KP-250 PG2 User’s Guide 3 . Arm ing a nd Disa rm ing t he Syst e m PRESS RESULTING DISPLAY Move to interior zone (ARM HOME) AWAY/HOME ARM indicator on both the KP-250 PG2 keypad and PowerMaster panel lights steadily during the armed state. Disarming and Stopping Alarm Enter the protected premises via a delayed zone. Upon detecting your entrance, the system will start sounding the entry delay beeps alerting you to disarm the system before the entry delay ends. After disarming, different displays may appear indicating that the system is in a state of alarm MEMORY. The MEMORY message will disappear only upon rearming the system. To disarm the system, proceed as shown: PRESS RESULTING DISPLAY PRESENT TAG OR ENTER CODE: Enter code / present tag Code / present tag ARM indicator on both the KP-250 PG2 keypad and PowerMaster panel extinguishes during the disarmed state. Disarming the system also stops the siren alarm, irrespective of whether the alarm was initiated during the armed or the disarmed state. Disarming under Duress If you are forcibly compelled to disarm the system, enter the duress code (2580 by default) or another code set by the installer. Disarming will take place normally but a silent alarm will be transmitted to the monitoring station. Partition Selection Process Access to any desired partition is achieved through the use of an individual code or proximity tag. It is not possible to access the INSTALLER MENU if one or more partitions are in the AWAY or HOME modes. Before attempting to perform any operation on any given partition(s), it is necessary to perform the operations below which enable you to select the desired/allowed partition(s) using the individual code or proximity tag: PRESS RESULTING DISPLAY SELECT PARTITION Enter partition # (1 - 3) PARTITION 1 Notes: 1. The “Sad Tune” will be heard when selecting a partition to which no sensors / peripherals were enrolled. 2. If a partition is enabled and no zones are assigned to the partition, the PG2 keypad display. icon will appear on the KP-250 Spe c ia l Arm ing & Disa rm ing Opt ions In addition to basic arming, KP-250 PG2 provides you with several advanced arming and disarming options: D-304269 KP-250 PG2 User’s Guide 3 . Arm ing a nd Disa rm ing t he Syst e m Switching from ‘HOME’ to ‘AWAY’ You do not have to disarm the system - just press Vacate the premises before the exit delay expires. . The response will be the same as in ARMING AWAY above. Switching from ‘AWAY’ to ‘HOME’ You do not have to disarm the system - just press . Since this operation reduces the security level, KP-250 PG2 will ask you to key in your master user code or user code, or to present your proximity tag, thus making sure that you are an authorized user. PRESS RESULTING DISPLAY PRESENT TAG OR ENTER CODE: Enter code / present tag Code / present tag ARMING HOME Move to interior zone (Exit delay) HH:MM HOME ARM indicator flashes on both the KP-250 PG2 keypad and PowerMaster panel during the armed state. Arming AWAY or HOME ‘Instant’ Pressing during the exit delay will arm the system in the "Instant' mode, i.e. without an entry delay. Therefore, any detection in any zone will trigger an immediate alarm. To arm AWAY-INSTANT, proceed as follows. PRESS RESULTING DISPLAY PRESENT TAG OR ENTER CODE: Enter code / present tag Code / present tag ARMING AWAY ARMING INSTANT PLEASE EXIT NOW (Exit delay) Vacate the premises AWAY ARM indicator on both the KP-250 PG2 keypad and PowerMaster panel lights during the armed state. Forced Arming AWAY or HOME Forced arming allows you to arm the system even if the system is "NOT READY". Any open zones will be bypassed for the duration of arming. Note: When forced arming is carried out, the buzzer “protests” by emitting a continuous tone during the exit delay until D-304269 KP-250 PG2 User’s Guide 3 . Arm ing a nd Disa rm ing t he Syst e m the last 10 seconds of the delay. You can silence this signal by pressing the arming button again. If forced arming is enabled and you wish to arm the system when NOT READY is displayed, proceed as shown: PRESS RESULTING DISPLAY PRESENT TAG OR ENTER CODE: Enter code / present tag Code / present tag ARMING AWAY PLEASE EXIT NOW (to mute the buzzer) Vacate the premises (Exit delay) AWAY ARM indicator on both the KP-250 PG2 keypad and PowerMaster panel lights during the armed state. Remember: Forced arming compromises security!! Forced arming “HOME” is performed in a similar manner, as follows: PRESS RESULTING DISPLAY PRESENT TAG OR ENTER CODE: Enter code / present tag Code / present tag ARMING HOME PLEASE EXIT NOW (to mute the buzzer) Vacate the premises HH:MM (Exit delay) HOME ARM indicator on both the KP-250 PG2 keypad and PowerMaster panel flashes during the armed state. D-304269 KP-250 PG2 User’s Guide 3 . Arm ing a nd Disa rm ing t he Syst e m Arming in the Latchkey Mode This mode, if enabled by the installer, is useful for a parent at work who wants to be sure that his children have returned from school and have disarmed the system. A special “latchkey” message will be sent out when the system is disarmed by a “latchkey user”. Latchkey users are holders of user codes or users of keyfob transmitters 5-8 (PowerMaster-10 G2) / 23-32 (PowerMaster-30 G2 / PowerMaster-33 G2). The latchkey message is considered an alert and not an alarm, and is therefore sent to the private telephones programmed by the user as targets for alert messages. Latchkey arming is possible only when you arm “AWAY”. To arm in the Latchkey mode, proceed as follows: PRESS RESULTING DISPLAY ARMING AWAY ARMING LATCHKEY PLEASE EXIT NOW Vacate the premises (Exit delay) AWAY Note: Latchkey must be enabled by your installer. ARM indicator on both the KP-250 PG2 keypad and PowerMaster panel lights during the armed state. I nit ia t ing Ala rm s Following are various methods that may be used for initiating alarms. Initiating Panic Alarm You can generate a panic alarm manually in the disarmed and armed states. The sequence will be as shown: PRESS RESULTING DISPLAY PANIC ALARM simultaneously for 2 seconds HH:MM To stop the alarm, press the 10 READY button and then key in your valid user code. D-304269 KP-250 PG2 User’s Guide 3 . Arm ing a nd Disa rm ing t he Syst e m Initiating Fire Alarm or Emergency Alarm You can generate a fire alarm or a silent emergency alarm in disarmed & armed states, as follows: PRESS RESULTING DISPLAY FIRE ALARM OR EMERGENCY for 2 seconds Then, if or when the system is in the disarmed state: HH:MM READY (alternating) READY MEMORY To stop the alarm, press and then key in your valid user code. Chime ON/OFF Disable / enable the chime zones by alternate clicking of the PRESS key, as shown below: RESULTING DISPLAY CHIME ON CHIME OFF HH:MM READY CHIME indicator lights steadily on the KP-250 PG2 keypad, when “chime on” is selected. D-304269 KP-250 PG2 User’s Guide 11 3 . Arm ing a nd Disa rm ing t he Syst e m Adjusting the Volume of the Keypad Beeps The following diagrams show how to increase or decrease the loudness by clicking the <1> or<4> key on the KP-250 PG2 keypad (assuming that the volume was at minimum/maximum to begin with). PRESS RESULTING DISPLAY PRESS VOLUME+ RESULTING DISPLAY VOLUME (max) VOLUME+ VOLUME VOLUME+ VOLUME VOLUME+ VOLUME (max) 12 D-304269 KP-250 PG2 User’s Guide 4 . Syst e m St a t us a nd I ndic a t ions 4 . Syst e m St a t us a nd I ndic a t ions Note: The icons and numbers shown on the above keypad drawing are for illustrative purposes only. When executing a command, the KP-250 PG2 keypad's LED blinks red once to indicate transmission of the command to the control panel. If the operation is successfully completed, the green LED lights momentarily and a "happy tune" sounds. If the operation fails or cannot be completed, for example, when the system is "Not Ready", the red LED lights steadily and a "sad tune" sounds. LCD Displa y a nd Ge ne ra l Audible I ndic a t ors The display is in two lines and is used to display system status and events, time and date, programming instructions and also an event log file The sounds you will hear while using the system are: Sound Definition Single beep, heard whenever a key is pressed Double beep, indicates automatic return to the normal operating mode (by timeout). Three beeps, indicates a trouble event ♫ Happy Tune (- - - –––), indicates successful completion of an operation. ♫ Sad Tune (–––––), indicates a wrong move or rejection Arm ing I ndic a t ions The table below lists the Arming indication keys and their definition. Icon/Key Indications Arming Indication ARM AWAY ARM HOME DISARM EXIT DELAY The icons appear consecutively D-304269 KP-250 PG2 User’s Guide 13 4 . Syst e m St a t us a nd I ndic a t ions Ge ne ra l I ndic a t ions The Ready/Not Ready, Alarm Memory, Trouble and Low Battery indications are provided via the indications in the following table: Indication What it Means What it Means KP-250 PG2 low battery. Record a message Communication failure: KP-250 PG2 is out of range of panel PGM on Memory / Alarm in partition or system KP-250 PG2 Volume down A message is waiting in the control panel Play a message The system is in INSTALLER MODE or USER SETTINGS PGM off Instructs the user to present the proximity tag (at the position of this indication). PowerMaster Mute speaker AC ON Chime ON / OFF Keypad Chime ON / OFF status PGM control System Trouble Event log / enroll button Escape Instant Previous Partition selection Info. / OK Dialer to call telephone numbers (for future use) Next AC failure 14 Indication KP-250 PG2 Volume up Discard / abort D-304269 KP-250 PG2 User’s Guide 4 . Syst e m St a t us a nd I ndic a t ions Ala rm I ndic a t ion Sire n The PowerMaster system incorporates one or more high power sirens that sound in case of alarm. A siren can sound from either the control panel or from a device and may be a part of a system component. Alarm Type Graphic Representation of Signal Verbal Description of Signal Burglar / 24 hour/ Panic ––––––––––––––––––––––––––––––– ON continuously Fire ––– ––– ON - ON - ON - pause - ON - ON - ON - pause..... Flood – – Gas –––– Test* –– (both external siren and internal sounder) – ––– – – – ................. ................. –––– –––– ON - pause - ON - pause - ON - pause..... –––– ........ ON - ON - ON - ON - pause - ON - ON - ON - ON pause..... ON for 2 seconds (once) * Not included in all models D-304269 KP-250 PG2 User’s Guide 15 5 . Re vie w ing T rouble s a nd Ala rm M e m ory 5 . Re vie w ing T rouble s a nd Ala rm M e m ory Ala rm & T a m pe r M e m ory I ndic a t ion The KP-250 PG2 retains in its memory alarm and “tamper” events that occurred during the last arming period. Note: Alarm events are memorized only after the “abort period”. This means that if you disarm the system immediately before the abort period expires - there will be no memory indication A. Indication of Alarm & Tamper Condition If the system is disarmed following an alarm event, a flashing MEMORY message will be displayed, as follows: HH:MM READY MEMORY B. Displaying Alarm & Tamper Information To review memory content, click button. EXAMPLE: An alarm was triggered because the garage door - zone No. 12 – was opened but then closed. In addition, the bedroom motion detector - zone No. 7 - sent a “Tamper” message because its cover had been removed. PRESS RESULTING DISPLAY PRESS RESULTING DISPLAY KP-250 V 1.0.07 Bedroom Z07 TAMPER OPEN Garage door Z12 ALARMED Z06 Motion sens Z07 TAMPER OPEN (alternating) (alternating) Z03 contact Z12 ALARMED In response to additional clicking of the button, the display shows details of other events retained in open tamper (if any), or reverts to its initial state (see A above). If the system is NOT READY, the display will first read the open zones and then alarm memory events. Cle a ring t he M e m ory I ndic a t ion To clear the ‘Memory’ indication you must first review the cause of alarm as described above. Once you return to the ‘Ready’ screen simply press Away and enter the code if requested, then press Disarm followed by the code. The memory message will now clear. Otherwise the memory indication and content will be cleared upon the next arming of the system. T rouble s A. Indication of Trouble condition If the system detected a trouble condition in any of the enrolled devices, the TROUBLE indicator illuminates, 3 beeps are sounded once per minute and a flashing TRBL message is displayed, as follows. HH:MM READY TROUBLE HH:MM NOT READY TROUBLE or, if the system is not ready for arming 16 D-304269 KP-250 PG2 User’s Guide 5 . Re vie w ing T rouble s a nd Ala rm M e m ory B. Displaying Trouble Information All trouble messages need to be reviewed and corrected as described below: EXAMPLE: The kitchen device - zone No. 9 - has reported a low battery – the living room device zone No. 15 - has been inactive, and an attempt to communicate a message to your telephone has failed. However, these troubles do not prevent the system from being “ready to arm”. To review the source of the current troubles one by one, click the PRESS RESULTING DISPLAY button repeatedly as shown below: PRESS RESULTING DISPLAY KP-250 V 1.0.07 Living room Z15 MISSING Kitchen Z09 LOW BATTERY Z15 Motion sens Z15 MISSING (alternating) (alternating) Z09 Contact Z09 LOW BATTERY IMPORTANT! If the trouble beeps bother you, disarm the system again (even though it is already disarmed). This will cancel the trouble beeps for 4 hours. C. Reviewing Memory & Troubles at the Same Time If alarms / tamper events are retained in the alarm memory and at the same time a state of trouble exists, the display will first read the alarm memory followed by trouble events, as described in sections A & B above. GSM /GPRS St a t us I ndic a t ions After all trouble messages have been reviewed and if a SIM card is installed in the panel, the KP-250 PG2 displays the GSM signal strength indication, as follows: "GSM RSSI STRONG" / "GSM RSSI GOOD" / "GSM RSSI POOR". If a PIR camera is enrolled in the system, the control panel will read "GPRS initialize" to indicate that the modem is undergoing initialization. This message appears at the end of all trouble messages and immediately following the GSM signal strength indication (if a SIM card is installed). D-304269 KP-250 PG2 User’s Guide 17 5 . Re vie w ing T rouble s a nd Ala rm M e m ory T rouble I ndic a t ions The trouble indications (illuminated TROUBLE indicator and flashing TRBL message) are cleared once you eliminate the cause of trouble. Fault What it means 1-WAY The device functions but cannot "hear" the panel. The control panel cannot configure or control the device. Battery consumption increases. There is no power supplied to the device. AC FAILURE The fire detector must be cleaned FIRE CLEAN COMM. FAILURE A message could not be sent to the monitoring station or to a private telephone (or a message was sent but was not acknowledged) CPU LOW BATTERY The backup battery within the control panel is weak and must be replaced (see PowerMaster-10/30 G2 Installer’s Guide, section 7.3, or, PowerMaster-33 G2 Installer’s Guide, section 5.2). CPU TAMPER OPEN The control panel was physically tampered with or its cover was opened, or it was removed from wall. Gas detector failure GAS TROUBLE The GSM communicator is not able to connect to the cellular network. GAS NET FAIL SYSTEM JAMM A radio-frequency signal which is blocking all communication frequency channels between the sensors and control panel is detected. There is a problem with the telephone line LINE FAILURE The battery of the indicated device is near the end of its useful life. LOW BATTERY A device or detector has not reported for some time to the control panel. MISSING NOT NETWORKED A device was not installed or not installed correctly, or, cannot establish communication with the control panel after installation. The GSM communicator has detected that GSM network signal is weak RSSI LOW There is no power to the siren SIREN AC FAILURE The sensor has an open tamper TAMPER FAILURE The sensor reports trouble TROUBLE Detector alarms when is Soak Test mode SOAK TEST FAIL 18 D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion 6 . Syst e m Configura t ion This chapter explains the user programming features of your PowerMaster system using the KP-250 PG2 keypad. To access the User Settings menus, a KP-250 PG2 keypad must first be enrolled in the system. For instructions on how to enroll the KP-250 PG2 Keypad, refer to the KP-250 PG2 Installer’s Guide, section 11.4. The Master User has access to all the User Settings menus, while the User has access only to the bypass menus (see section B.4 in this chapter, which describes in detail the concept of User and Master User codes). A.1 Ent e ring t he U se r Se t t ings M e nu & Se le c t ing a Se t t ing Opt ion The following procedure describes how to enter and move within the User Settings menu. Detailed descriptions of the User Settings options are provided at the end of the procedure. To exit the User Settings menu – see section A.2. can enter the "USER SETTINGS" menu only when the system is disarmed. 1.2. You Carefully read the section titled "Additional Information" according to the indicated references etc – see table at end of this section. A. To Enter the USER SETTINGS Menu 1. 2. HH:MM READY USER SETTINGS PRESENT TAG OR ENTER CODE: 3. Make sure the system is disarmed and then press the button repeatedly on the KP-250 PG2 until the display reads [USER SETTINGS]. 1 Press The screen will now prompt you to enter your user code or present your proximity tag. Enter your User Code. 2 CODE SET ZONE BYPASS The display reads the first Setting option of the User Settings menu [SET ZONE BYPASS]. 3 B. To Select a Setting Option 4. SET ZONE BYPASS Click the or button until the display reads the desired setting option, for example, "TIME & FORMAT". or 5. TIME & FORMAT Continue to the selected setting option in B.1 - B.16 When the desired setting option appears on the display, press the enter the setting process. button to The remainder of the procedures for the selected setting options is provided in sections B.1 to B.16. Additional Information (section A.1) Display shown in disarm state when all zones are secured (00:00 or other digits show present time). D-304269 KP-250 PG2 User’s Guide 19 6 . Syst e m Configura t ion a. If you have not already changed your personal code number, use the default setting – 1111. b. Master User has access to all User Settings options. Other users have access only to the Bypass options. c. If you enter an invalid user code 5 times, the keypad will be automatically disabled for a pre-defined period of time and the message WRONG PASSWORD will be displayed. The bypass options will be displayed in the User Settings menu only if enabled by the installer. Otherwise, the first User Settings option displayed will be [USER CODES]. C. User Settings Options Menu Click until the display reads the desired setting option and then press SET ZONE BYPASS Use to set the Zone Bypass Scheme i.e. to bypass (exclude) faulty or unsecured ("disturbed") zones, or to clear a bypassed zone (unbypass). For further details and programming procedure see section B.1. REVIEW BYPASS Use to quickly review the Bypass Scheme i.e. which zones are bypassed. For further details and reviewing procedure see section B.2. RECALL BYPASS Use to Recall the last used bypassed scheme for reuse in next arming period. For further details and recalling procedure see section B.3. USER CODES Use to program your Master User secret access code and the seven codes of the other users. For further details and programming procedure see section B.4. DURESS ALARM CODE 2580 Use to send a duress (ambush) alarm message to the Monitoring Station if you are forced to disarm the system under violence or menace. For further details and programming procedure see section B.5. PROXIMITY TAGS Use to add new Proximity Tags to or to delete Proximity Tags when lost. For further details and programming procedure see section B.6. KEYFOBS Use to add new Keyfob Transmitters or to delete Keyfob Transmitters when lost. For further details and programming procedure see section B.7. TIME & FORMAT Use to set the time clock to show the correct time and time format. For further details and programming procedure see section B.8. DATE & FORMAT Use to set the calendar date to show the correct date and date format. For further details and programming procedure see section B.9. AUTO-ARM disable Use to enable or disable the Automatic Daily Arming option at predefined times (see Auto-Arm Time setting). For further details and programming procedure see section B.10. 20 D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion AUTO-ARM TIME 12:00P Use to set the predetermined time for the Automatic Daily Arming if enabled (see AutoArm Enable setting). For further details and programming procedure see section B.11. PRIVATE REPORT Use to program the four private telephone numbers for reporting alarm and other event messages to private subscribers. For further details and programming procedure see section B.12. SQUAWK on Use to enable or disable the squawk sound i.e. arm / disarm feedback indication. For further details and programming procedure see section B.13. SCHEDULER Use to set the daily / weekly time schedule for start & stop activation of devices connected to the PGM output. For further details and programming procedure see section B.14. VOICE OPTION disable Use to enable or disable the voice option i.e. the voice prompts that are heard over the external voice box. For further details and programming procedure see section B.15. PANEL VOLUME Use to adjust the volume of the panel’s speaker or external voice box. For further details and programming procedure see section B.16. SERIAL NUMBER Use to read the system serial number and similar data. For further details see section B.17. TO EXIT Use to exit from the “USER SETTINGS” menu back to Main Menu. For further details see section A.2. Returns to first option A.2 Re t urning t o t he Pre vious St e p or Ex it ing t he U SER SET T I N GS M e nu During the setting process it is frequently necessary to return to the previous setting step or option (i.e. "to go one level up") or to exit the User Settings menu. 1. To Move One Level Up To move one level up during the setting process, click the previous setting step. once or more. Each click will take you one level up or to 2. To Exit the USER SETTINGS Menu 1. 2. Any screen or TO EXIT To exit [USER SETTINGS], move up the menu by pressing repeatedly (see above) until the display reads [ TO EXIT], or preferably, press which brings you immediately to the exit screen [ TO EXIT]. once When the display reads [ TO EXIT], press 3. D-304269 KP-250 PG2 User’s Guide 21 6 . Syst e m Configura t ion 12:00 READY The system exits the [USER SETTINGS] menu and returns to the normal disarm state while showing the READY display. A.3 But t ons use d for N a viga t ion & Se t t ing The keypad's buttons are used for various functions when programming. The following table provides a detailed description of the function or use of each button. Button Definition Navigation / Setting Function NEXT Use to move / scroll forward to the next menu options. BACK Use to move / scroll backward to the previous menu options. OK Use to select a menu option or to confirm a setting or action. Escape Use to move one level up in the menu or to return to previous setting step. Delete / abort Use to edit a field or jump back to the [ TO EXIT] screen to quit programming. Numerical keypad used to enter numerical data. Partition selection Use to change the status of partitions when programming user codes B.1 Se t t ing t he Z one Bypa ss Sc he m e Bypassing permits arming only part of the system and at the same time allowing free movement of people within certain zones when the system is armed. It is also used to temporarily remove from service faulty zones that require repair work or to deactivate a sensor if, for example, you are decorating a room. Here you can set the Zone Bypass Scheme i.e. to scroll through the list of registered (enrolled) sensors to your PowerMaster system and to Bypass (deactivate) faulty or disturbed sensors (either READY or NOT-READY) or to Clear (reactivate) BYPASSED zones (sensors). Once you have set a Bypass Scheme you can use the following 3 options: To quickly review the bypassed zones – refer to section B.2. To quickly clear a bypassed zone i.e. to reactivate the bypassed zone – refer to section B.1. To repeat (recall) the last used zone bypassing scheme – refer to section B.3. 1. 2. 3. Zones will be bypassed throughout one disarm-arm period only. Disarming the system after arming will suspend the entire bypassing scheme but you can recall and reuse it as described in section B.3. Fire zones cannot be bypassed. Carefully read the section titled "Additional Information" according to the indicated references 1 etc – see table at end of section B.3. REMEMBER – ZONE BYPASSING COMPROMISES SECURITY! 22 D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion A. To Bypass a Zone 1. SET ZONE BYPASS Enter the [USER SETTINGS] menu1, select the [SET ZONE BYPASS] 2 option and press Z01: READY Living Room The first zone, Z01, is displayed. 3 Z01: P1 P2 P3 2. or Click the or button until the display reads the zone you wish to bypass (or clear bypass), for example, "Z04" for Zone 04. After several seconds the LEDs on the respective device starts flashing indicating "it's me". Z04: NOT READY Z04: P1 P2 P3 3. 4. Kitchen TO BYPASS When the display reads the zone you wish to bypass press The display now reads [ TO BYPASS]. To bypass the selected zone press Z04:BYPASSED A "Happy Tune" ☺ sounds and the updated zone status is now displayed i.e. [Z04: BYPASSED]. 8 B. To Clear a Bypassed Zone 5. Z04: BYPASSED Z04: P1 P2 P3 6. Kitchen Repeat steps 1 to 2 above. When the zone you wish to clear bypass appears on the display (for example, "Z04"), press to confirm. You can also identify the device by looking for the "it's me" LED indication on the displayed device. TO CLEAR The display now reads [ TO CLEAR]. 5 7. To clear the bypassed zone, press the Z04:READY button. A "Happy Tune" ☺ sounds and the updated zone status is now displayed, i.e. [Z04: READY] or [Z04: NOT READY]. 9 D-304269 KP-250 PG2 User’s Guide 23 6 . Syst e m Configura t ion B.2 Re vie w ing t he Z one Bypa ss Sc he m e 1. Here you can quickly review the Bypass Scheme i.e. the zones that are set to be bypassed during the next arming session. REVIEW BYPASS Enter the [USER SETTINGS] menu and select the [REVIEW BYPASS]1 option and press 2. BYPASS LIST or .2 The display reads [BYPASS LIST] Click the or buttons repeatedly to review all bypassed zones in to exit. 9 ascending numerical order. When done, click 3. Z04: BYPASSED Z04: P1 P2 P3 Kitchen B.3 Re c a lling t he Z one Bypa ss Sc he m e 1. Use this option to repeat (recall) the most recent Bypassed Scheme for use during the next arming session. RECALL BYPASS Enter the [USER SETTINGS] menu, select the [RECALL BYPASS] 1 option and press 2. TO RECALL . 2, 6 The display now reads [ TO RECALL]. 7 To recall the last used bypass scheme press BYPASS RECALLED ☺ A "Happy Tune" sounds. The display reads [BYPASS RECALLED] and then returns to “USER SETTINGS" step 1. 9 ☺ Return to step 1 Additional Information (section B.1 – B.3) For detailed instructions on how to select User Settings – refer to section A.1 and section A.2. This menu is displayed only if "BYPASS" was previously enabled by the installer. The STATUS to the right of the zone number indicates whether the zone is READY, NOT-READY or BYPASSED. This display will appear only if PARTITIONING was previously enabled. 24 D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion a. If the zone you selected is "not bypassed", the display prompts you to press [ TO BYPASS]. However, if the zone you selected is already "bypassed", the display prompts you to press [ TO CLEAR]. b. To abort and return to the previous step press or This menu is not displayed if Partition is enabled. The display now prompts you to press [ TO RECALL] i.e. to repeat the last used bypass scheme. To abort and return to the User Settings menu, press You can now repeat steps 2 - 4 to bypass or clear another zone. To end this session and to select other menu options or to quit programming - follow the instructions in section A.2. You can now select another option in the User Settings menu (see section A.1), or quit programming (see section A.2). B.4 Progra m m ing U se r Code s PowerMaster system allows you to authorize up to 8 (PowerMaster-10 G2) / 48 (PowerMaster-30 G2 / PowerMaster-33 G2) people to arm and disarm the system by providing each with a unique 4 digit personal security code (code 0000 is not allowed), and assigning them with different security levels and functionalities. Moreover, you can obtain up to 8 (PowerMaster-10 G2) / 32 (PowerMaster-30 G2 / PowerMaster-33 G2) multi-function portable keyfob transmitters that will allow you and the other users to easily arm, disarm and control the system without accessing the KP-250 PG2 or panel, including from outside the premises (see section B.7 Add / Delete Keyfob Transmitters). The Duress Code enables you to disarm the system using a special code that sends a silent alarm to the monitoring station. There are two types of users: Master User and User. The table below summarizes the different operations that can be performed by different users: User type Master User User Function Arm/disarm Zone bypass Authorize other user codes Set user codes Report to private Enroll/delete proximity tag Enroll/delete keyfob Automatic arming Enable squawk Set date and time format Read event log Programming the duress code Programming the scheduler Enabling/disabling voice option Adjusting volume Arm/disarm Zone bypass options The user codes are assigned as follows: User Code 1 is assigned to the Master User of the system (i.e. the owner). It is the only user code that allows access to the User Settings menu. The default setting of the Master User code is 1111. This code cannot be erased and must be replaced with a secret code as soon as possible. User Codes 2-4 (PowerMaster-10 G2) / User Codes 2-22 and 33-48 (PowerMaster-30 G2 / PowerMaster-33 G2) are assigned to family members, co-workers etc. They enable arming and disarming of the system or of selected partitions as defined by the Master User. They can access the "User Settings" menu only for "zone bypassing" provided this option is enabled in the Installer menu. D-304269 KP-250 PG2 User’s Guide 25 6 . Syst e m Configura t ion User Codes 5-8 (PowerMaster-10 G2) / User Codes 23-32 (PowerMaster-30 G2 / PowerMaster-33 G2) are the same as user codes 2-4 (PowerMaster-10 G2) / 2-22 (PowerMaster-30 G2 / PowerMaster-33 G2) but can be assigned to "Latchkey" (child monitor) users. For a detailed explanation of the Latchkey application see Chapter 3. Partition Option (For information about Partition option - see APPENDIX B) Your alarm system can divide zones into up to 3 parts (groups) via the installer menu. These parts are designated as partitions P1, P2 & P3. Each partition can be armed and disarmed separately, providing protection to selected parts of the premises. Each user out of the 8 (PowerMaster-10 G2) / 48 (PowerMaster-30 G2 / PowerMaster-33 G2) system users can be authorized by the Master User to arm and disarm any combination of partitions including all 3 partitions. Here you can program (or edit) the 8 (PowerMaster-10 G2) / 48 (PowerMaster-30 G2 / PowerMaster-33 G2) User Codes and thereby define which of these will be authorized to arm and disarm. 1. The default setting 1111 of the Master User Code is the same for all PowerMaster systems and is known to many other people. Therefore, we highly recommend that you immediately replace it with a unique secret code. 2. Code "0000" is not valid! Do not use it. 3. The duress code (2580 by default), which is set in the installer menu, cannot be selected as a normal user code. Any attempt to program it will be rejected by the system. 4. Carefully read the section titled "Additional Information" according to the indicated references 1 etc – see table at end of this section. A. To Program a User Code 1. USER CODES Enter the [USER SETTINGS] menu, select the [USER CODES] option and press .1 2. User 01: 1111 or The first user code "User 01: 1111" is displayed. 2 At the blinking cursor position, key in the User Code you wish to program , for example, [06] for user code 6, or alternatively click the the display reads, [User 06: 0000]. 3. User 06: 0000 4. User 06: 0000 or button until When the user code you wish to program appears on the display, press To program or edit the code, at the blinking cursor position enter the 4 digit code, for example, “1234”, using the numerical keypad. 3, 4 5. When done, press User 06: 1234 ☺ Return to step 3 26 ☺ sounds. The display confirms the saved code. 5, 6 A "Happy Tune" D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion B. To Set Partitions Authorization 6. User 06: 1234 1 2 3 The display will now enable you to set the partitions. 7 7. User 06: 1234 1 2 3 Press the button and use the keypad keys to change the status of the partitions 1, 2 & 3, respectively. 8 When you are satisfied with the setting, for example, User 6 is authorized with Partition 1 and 3 only, press ☺ Return to step 3 to confirm. ☺ sounds. The display confirms the Partition setting. 9 A "Happy Tune" Additional Information (section B.4) For detailed instructions on how to select the setting options – refer to section A.1 and section A.2. The display shows the 1st User Code (Master User) in the list of 8 (PowerMaster-10 G2) / 48 (PowerMaster-30 G2 / PowerMaster-33 G2) User Codes. If you have not yet changed the default code 1111, we recommend that you change it now. a. The display shows the user code currently programmed in this location (e.g. 5327). b. The cursor blinks on the first digit of the code. c. If the location is free the display will be (0000). You can move the cursor to the next or previous digit by pressing digit of the cursor + all digits to the right of the cursor. or . Pressing erases the a. The new code is momentarily displayed without the cursor before reverting to step 3. b. If Partition is enabled, continue to step 6. You can now repeat steps 3 - 5 to program or edit another user code. To end this session and to select other menu options or to quit programming – follow the instructions in section A.2. This setting can be performed only after completing steps 1 - 5 of section B.4A. At this stage, pressing the button continuously switches between the first and second rows. You can now repeat steps 3 - 7 to program or edit another user code. B.5 Progra m m ing t he Dure ss Code A duress (ambush) alarm message can be sent to the Monitoring Station if you are forced to disarm the system under violence or menace. To initiate a duress message, you must disarm the system using a duress code (2580 by default) Here you program the duress code. Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. Refers to when PARTITIONING is enabled. D-304269 KP-250 PG2 User’s Guide 27 6 . Syst e m Configura t ion 1. 2. DURESS CODE 2580 Enter the [USER SETTINGS] menu, select the [DURESS CODE] option and press DURESS CODE 2580 At the blinking cursor position, key in the Duress Code you wish to program, for example, 6973. 2, 3 DURESS CODE 6973 When the duress code you wish to program appears on the display, press .1 3. ☺ Return to step 1 ☺ sounds and The display confirms the saved setting. 4 A "Happy Tune" Additional Information (section B.5) For detailed instructions on how to select User Settings – refer to section A.1 and section A.2. The display shows the default duress code (2580). Do not set the duress code the same as an installer or user code. You can now select another option in the User Settings menu or quit programming (see sections A.1 and A.2). B.6 Add / De le t e Prox im it y T a gs Users of the alarm system may be provided with a proximity tag/s that can be used instead of the user codes to perform a variety of functions, for example, arming, disarming, reading the event log, etc. Whenever a user code is required you can simply present a valid proximity tag instead of entering the user code. Here you can add (enroll) new proximity tags or delete tags as required. Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. A. To Add (Enroll) a Proximity Tag 1. TAGS (Proximity) Enter the [USER SETTINGS] menu, select the [TAGS (Proximity)] option and press 2. 28 ADD NEW TAG 3. ENROLL NOW or ENTR ID:xxx-xxxx 4. DEVICE ENROLLED T01:Tag (Prox) .1 The display will read [ADD NEW TAG]. 3 To begin the process of enrolling a new proximity tag press Present the proximity tag to the KP-250 PG2 within the timeout period. If enrollment was successfully completed, a "Happy Tune" ☺ sounds and the display reads [DEVICE ENROLLED] for a short duration and then changes to read D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion ☺ Go to step 5 5. or DEVICE ENROLLED T05:Tag (Prox) ☺ Return to step 2 the tag's details. 4 The display shows the allocated tag serial No (user No.), which is always the first free number, for example: [T01:Tag (Prox)]. To assign the tag to another user, for example, "User No. 5", key in [05] or alternatively click the or (Prox)] and then press button until the display reads [T05:Tag to confirm. The display reads [DEVICE ENROLLED] a "Happy Tune" ☺ sounds and the display will then change to [T01:Tag (Prox)]. 5 6 B. To Set Partitions Authorization 6. T05:PARTITIONS 1 2 3 Use the keypad keys 3, respectively. 9 7. T05:PARTITIONS 1 2 3 When you are satisfied with the setting, for example, User 5 is authorized with ☺ Return to step 2 Partition 1 and 3 only, press to change the status of the partitions 1, 2 & to confirm. ☺ sounds. The display confirms the Partition setting. 10 A "Happy Tune" C. To Delete a Proximity Tag 1. TAGS (Proximity) Enter the [USER SETTINGS] menu, select the [TAGS (Proximity)] option and .1 press 2. ADD NEW TAG The display will read [ADD NEW TAG]. Click the 3. DELETE TAG T01:Tag (Prox) Press button until the display reads [DELETE TAG]. The display will read [T01:Tag (prox)]. 2, 7 Key in the tag number you wish to delete, for example, [05] or alternatively click the 4. or button until the display reads the tag number, [T05:Tag (prox)]. 5. When the tag you wish to delete appears on the display, press to delete The display now reads [to delete]. 8 Refers to when PARTITIONING is enabled. D-304269 KP-250 PG2 User’s Guide 29 6 . Syst e m Configura t ion 6. To delete the tag press the DELETE TAG button. A "Happy Tune" ☺ sounds and the display reads [DELETE TAG] and returns to step 3. 11 ☺ Go to step 3 Additional Information (section B.6) For detailed instructions on how to select User Settings – refer to section A.1 and section A.2. The display shows the first enrolled Tag (Tag No.1) of the 8 (PowerMaster-10 G2) / 32 (PowerMaster-30 G2 / PowerMaster-33 G2) tags. To abort enrollment, press the button. If the tag was previously enrolled in the system, the KP-250 PG2 display indicates this together with the tag's ID number, for example, "ALREADY ENROLLED T01:Tag (Prox)". If Partition is enabled, continue to step 6. You can now enroll another proximity tag. You can also select another option in the User Settings menu (see If no proximity tag is enrolled in the system, the display reads [NO EXISTING DEV.]. section A.1 and section A.2), or quit programming (see section A.3). To abort the procedure, press the button. This setting can be performed only after completing steps 1 - 5 of section B.6A. 10 You can now repeat steps 2 - 7 to program or edit another Proximity tag. 11 You can now add or delete another proximity tag. You can also select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). B.7 Add / De le t e K e yfob T ra nsm it t e rs Each of the 8 (PowerMaster-10 G2) / 32 (PowerMaster-30 G2 / PowerMaster-33 G2) users may be provided with a portable keyfob transmitter for better, quicker and safer arming/disarming and other control functions. Each keyfob should be assigned with a serial No. 1-8 (PowerMaster-10 G2) / 1-32 (PowerMaster-30 G2 / PowerMaster-33 G2) and enrolled into the system correspondingly. Partition Option (For information about Partition option - see APPENDIX B). If the Partition option is enabled in the KP-250 PG2, each of the 8 (PowerMaster-10 G2) / 32 (PowerMaster-30 G2 / PowerMaster-33 G2) keyfobs can be authorized by the Master User to arm and disarm any combination, or all 3 partitions, irrespective of the authorization of its corresponding user code. 30 Here you can add (enroll) the 8 (PowerMaster-10 G2) / 32 (PowerMaster-30 G2 / PowerMaster-33 G2) Keyfob transmitters and define which of the 3 partitions each of the keyfob will be authorized to arm and disarm, or delete keyfobs as required. 1. 2. Before anything else, gather up all keyfob units you intend to enroll and make sure they all have batteries installed and that they are active (the LED blinks upon pressing any of the buttons). Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion A. To Add (Enroll) a Keyfob 1. Enter the [USER SETTINGS] menu, select the [KEYFOBS] option and press KEYFOBS .1 2. ADD NEW KEYFOB 3. ENROLL NOW or ENTR ID:xxx-xxxx The display will read [ADD NEW KEYFOB]. 4 To enroll a new keyfob press The display offers you two alternative methods to enroll a keyfob: A: ENROLL NOW: Press and hold the AUX button on the selected keyfob until the LED is constantly on. 2 This procedure completes the enrollment. 4a. DEVICE ENROLLED ID No. 300-5786 ☺ If enrollment was successfully completed, a "Happy Tune" sounds and the display reads [DEVICE ENROLLED] for a short duration and then changes to read the keyfob's details. Continue to step 5. DEVICE ENROLLED F01:KEYFOB ☺ Go to step 5 4b. ID No. 300-5786 B: ENROLLMENT BY DEVICE ID: Enter the 7-digit number that appears on the keyfob sticker and then press to confirm. To complete the enrollment procedure, see Note 9 in the Additional Information table below. ID ACCEPTED ☺ sounds and the display reads If a valid ID was entered, a "Happy Tune" [ID ACCEPTED] for a short duration and then changes to read the keyfob's details. ☺ Go to step 5 5. F01:keyfob ID No. 300-5786 or Continue to step 5. The display shows the allocated keyfob serial No (user No.), which is always the first free number, and the keyfob's ID number; for example: [F01:Keyfob] alternating with [ID No. 300-5786]. To assign the keyfob to another user, for example, "User No. 5", key in [05] or alternatively click the or button until the display reads [F05:Keyfob] F05:keyfob and then press ☺ Return to step 2 to confirm. The display reads [DEVICE ENROLLED] or [ID accepted] if the keyfob was enrolled manually by entering the ID number, a "Happy Tune" sounds and the display will then change to [F01:Keyfob]. 5 6 D-304269 KP-250 PG2 User’s Guide ☺ 31 6 . Syst e m Configura t ion B. To Set Partitions Authorization 6. F05:PARTITIONS 7. F05:PARTITIONS 1 2 3 8. F05:PARTITIONS 1 2 3 ☺ Return to step 2 Press to enter partitions mode. Use the keypad keys respectively. 10 to change the status of the partitions 1, 2 & 3, When you are satisfied with the setting, for example, User 5 is authorized with Partition 2 and 3 only, press to confirm. 11 ☺ sounds. The display confirms the Partition setting. 12 A "Happy Tune" C. To Delete a Keyfob 1. KEYFOBS Enter the [USER SETTINGS] menu, select the [KEYFOBS] option and press .1 2. 3. ADD NEW KEYFOB DELETE KEYFOB F01:Keyfob ID No. 300-5786 4. or The display will read [ADD NEW KEYFOB]. Click the button until the display reads [DELETE KEYFOB]. Press The display will read [F01:Keyfob] and the ID number of the keyfob. 3 Key in the keyfob number you wish to delete, for example, [06] or alternatively click the or button until the display reads the keyfob number, for example, "F06:Keyfob" and "ID No. 300-5799". F06:Keyfob ID No. 300-5799 When the keyfob you wish to delete appears on the display, press .7 5. The display now reads [to Delete]. 8to Delete 6. To delete the keyfob press the button. 13 Refers to when PARTITIONING is enabled. 32 D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion ☺ Go to step 3 DELETE KEYFOB ☺ sounds and the display reads [DELETE KEYFOB] and A "Happy Tune" returns to step 3. 14 Additional Information (section B.7) For detailed instructions on how to select User Settings – refer to section A.1 and section A.2. The LED will extinguish after several seconds. In case of difficulties in communication with the control panel, the LED may blink for several seconds more while trying to establish communication. During this period of time the keyfob keys are disabled. The display shows the first enrolled Keyfob (Keyfob No.1) of the 8 (PowerMaster-10) / 32 (PowerMaster-30 G2 / PowerMaster-33 G2) keyfobs. To abort enrollment, press the button. If Partition is enabled, continue to step 6. You can now enroll another keyfob. You can also select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). If the keyfob was previously enrolled in the system, the KP-250 PG2 display indicates this together with the keyfob's ID number, for example, "ALREADY ENROLLED F01:KEYFOBS". Before you delete a keyfob, identify the keyfob either by the keyfob No., for example, F06, or by the ID number of the keyfob that appears on the display, and then make sure that it is the keyfob you wish to delete. Enrollment by Device ID: Step 4b enables you to register the device ID and to complete the programming process without being in possession of the device itself (can also be performed off-site by the installer). Enrollment can then be completed at a later stage by following the same enrollment procedure described in Step 3 without entering the User Settings menu. 10 This setting can be performed only after completing steps 1 - 5 of section B.7A. 11 The box symbol now appears next to the newly selected Partitions. 12 You can now repeat steps 2 - 8 to program or edit another keyfob. 13 To abort the procedure, press the 14 You can now add or delete another keyfob or select another option in the User Settings menu or quit programming (see sections A.1 and section A.2). button. B.8 Se t t ing t he T im e & T im e Form a t Here you can program or adjust the built-in-clock to show the correct time in the desired time format. You can select between a 24 hour and a 12 hour (AM/PM) time format. Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. D-304269 KP-250 PG2 User’s Guide 33 6 . Syst e m Configura t ion A. To Set the Time Format 1. TIME & FORMAT Enter the [USER SETTINGS] menu and select the [TIME & FORMAT] option and press 2. EU FORMAT 24H TIME: 19:22 or US FORMAT-12H TIME: 03:15P .1 The display shows the currently selected time format. 2 Click the or button until the display shows the desired time format, for example, "US FORMAT-24H" and press to confirm . 3. B. To Set the Time 5 4. US FORMAT-12H TIME: 03:15P At the blinking cursor position, enter the correct time, for example, “8:55A”, using the numerical keypad. 3 4 5. When you are satisfied with the setting, press US FORMAT-12H TIME: 08:55A to confirm. A "Happy Tune" ☺ sounds, the display reads the set time, returns to step 1. 6, 7 ☺ Return to step 1 Additional Information (section B.8) For detailed instructions on how to select User Settings – refer to section A.1 and section A.2. a. The display shows the currently selected format, for example, "24 Hrs". b. You can now select either the 12 Hrs or 24 Hrs time format using the or buttons. The display shows the Time in the selected Time Format, for example, "12:40 PM", with the cursor blinking on the first hour digit "1". The letter that follows the displayed time indicates one of the following: "A" = AM; "P" = PM and "none" for 24 Hrs time format. When the curser is positioned on the AM/PM digit, you can set to "AM" with the the button and the "PM" with button. You can move the cursor to the next or previous digit using the 34 or buttons. This setting can be performed only after completing steps 1 – 3 of section B.8A. The time saved is displayed without the cursor, for example, "08:55 A" followed by the selected time format. You can now select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion B.9 Se t t ing t he Da t e & Da t e Form a t Here you can program or adjust the built-in-calendar to show the correct date in the desired date format. You can select between a "mm/dd/yyyy" and a "dd/mm/yyyy" date format. Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. A. To Set the Date Format 1. DATE & FORMAT Enter the [USER SETTINGS] menu and select the [DATE & FORMAT] option and press DATE DD/MM/YYYY DATE: 01/01/2012 2. or DATE DD/MM/YYYY DATE: 01/01/2012 .1 The display shows the currently selected date format. 2 Click the or button until the display reads the desired date format, for example, "DD/MM/YYYY" and press to confirm. 3. B. To Set the Date 7 4. DATE DD/MM/YYYY DATE: 20/04/2012 5. At the blinking cursor position, enter the correct date, for example, “20/04/2012”, using the numerical keypad. 3, 4, 5 When you are satisfied with the setting, press DATE DD/MM/YYYY DATE: 20/04/2012 to confirm. A "Happy Tune" ☺ sounds, the display shows the set date and returns to step 1. 6 ☺ Return to step 1 Additional Information (section B.9) For detailed instructions on how to select User Settings – refer to section A.1 and section A.2. The display shows the currently selected format, for example, "DD/MM/YYYY". You can now select either the "MM/DD/YYYY" or "DD/MM/YYYY" date format by pressing or The display shows the Date and selected Date Format, for example, "30.12.2012", with the cursor blinking on the first digit. You can move the cursor to the next or previous digit using the or button. For the year, enter the two last digits only. You can now select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). This setting can be performed only after completing steps 1 – 3 of section B.9A. D-304269 KP-250 PG2 User’s Guide 35 6 . Syst e m Configura t ion B.1 0 Ena bling / Disa bling Aut o-Arm ing The PowerMaster system can be programmed to automatically arm itself on a daily basis at a predetermined time. This feature is useful especially in commercial applications, such as in stores, to ensure that the system is always armed and without having to assign security codes to employees. Here you can enable (activate) and disable (stop) the Auto-Arming. To set the Auto-Arming time – see section B.11. Auto-arming can arm a "NOT READY" system only if forced arming is enabled by the installer while programming your system. read the section titled "Additional Information" according to the indicated references Carefully end of this section. 1. etc – see table at AUTO-ARM enable Enter the [USER SETTINGS] menu, select the [AUTO-ARM] option and press AUTO-ARM enable The display shows the currently selected setting. 2 2. .1 or Click the or button until the display reads the desired setting, for example, [disable autoarm] and press to confirm. AUTO-ARM disable 3. AUTO-ARM disable A "Happy Tune" ☺ sounds. The display confirms the saved setting. 3 ☺ B.1 1 Se t t ing t he Aut o-Arm ing T im e 1. 2. Here you can program the exact time of the Auto-Arming. AUTO-ARM TIME 12:00 Enter the [USER SETTINGS] menu, select the [AUTO-ARM TIME] option and AUTO-ARM TIME 12:00 The display shows the current setting of the Auto-Arm Time. At the blinking cursor position, enter the correct time, for example, “8:30”, using the numerical keypad. 4 press .1 3. When you are satisfied with the setting, press AUTO-ARM TIME 08:30 to confirm. A "Happy Tune" ☺ sounds. The display confirms the saved time, then returns to the User Settings menu, step 1. 5, 6 ☺ Return to step 1 36 D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion Additional Information (section B.10 - B.11) For detailed instructions on how to select User Settings – refer to section A.1 and section A.2. The display shows the current setting, for example, [AUTO-ARM enable]. You can now select either to enable or disable auto-arming using the The or button. symbol now appears next to the newly selected option. The display shows the current setting of the Auto-Arm Time, for example, "12:00 PM", with the cursor blinking on the first hour digit "1". For detailed explanation of how to set the time - refer to Section B.8B. The saved auto arm time is displayed without the cursor, for example, "08:30 A". You can now select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). B.1 2 Progra m m ing Priva t e Phone a nd SM S Re port ing The PowerMaster system can be programmed to send various event notification messages such as alarm, arming or trouble events, to 4 private telephone subscribers by audible signal and, if a GSM option is installed, also to 4 SMS telephone numbers. These reports can be programmed either instead of or in addition to the reports transmitted to the monitoring company. Further details about the event notification by telephone and SMS are provided in the PowerMaster-10/30 G2 User Guide, Chapter 7 Event Reporting and Control by Telephone and SMS. You can also determine the number of times the private telephone number is dialed and whether a single acknowledge signal will stop the reporting process or an acknowledge signal from each telephone will be required before the current event is considered reported. Here you can program: The specific events you wish the system to report. The 1st, 2nd, 3rd, and 4th private telephone and SMS numbers for reporting alarm and other event messages to private subscribers. The number of redial attempts, two-way voice communication, and whether to use a single acknowledge signal or an acknowledge signal from each telephone before the current event is considered reported. Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. V OI CE REPORT A. To Program Events to be Reported to private telephone 1. PRIVATE REPORT Enter the [USER SETTINGS] menu and select the [PRIVATE REPORT] option and press 2. 3. VOICE REPORT .1 The display will read [VOICE REPORT]. To enter this option press REPORTED EVENTS disable report When the display reads [REPORTED EVENTS] press .2 Refers to system that is connected to the Voice Box D-304269 KP-250 PG2 User’s Guide 37 6 . Syst e m Configura t ion REPORTED EVENTS disable report 4. or REPORTED EVENTS alarms The display shows the currently selected option. Click the or button until the display reads the event group you wish to be reported via private phones, for example, [alarms]. 3 5. When you are satisfied with the setting, press REPORTED EVENTS alarms to confirm. A "Happy Tune" ☺ sounds. The display confirms the set events to be reported. 5, 12 ☺ B. To Program a Private Phone 6. REPORTED EVENTS alarms Click the or button until the display reads the desired Telephone No. you wish to program or edit, for example, "Private tel#2", and press or 7. Private tel#2 8. Private tel#2 8032759333 To program or edit the phone number, at the blinking cursor position enter the phone number, for example, “8032759333”, using the numerical keypad. 6, 7 9. When done, press Private tel#2 8032759333 to confirm. ☺ sounds and the display confirms the telephone number. 8, 12 A "Happy Tune" C. To Program the Number of Redial Attempts 10. Private tel#2 Click the press or button until the display reads [REDIAL ATTEMPTS] and or 11. REDIAL ATTEMPTS 3 alarms REDIAL ATTEMPTS 3 alarms 12. or REDIAL ATTEMPTS 4 alarms 38 The display shows the currently selected option. Click the or button until the display reads the desired number of redial attempts, for example, "4 attempts". 9 D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion 13. When you are satisfied with the setting, press REDIAL ATTEMPTS 4 alarms to confirm. ☺ sounds. The display confirms the set number of redial A "Happy Tune" attempts. 5, 12 D. To Program two-way voice communication 14. REDIAL ATTEMPTS 4 attempts Click the press or button until the display reads [Two Way Voice] and or Two way voice enable 15. Two way voice enable 16. or Two way voice disable The display shows the currently selected option. Click the or example, "disable". 10 button to select the voice communication method, for 17. When you are satisfied with the setting, press Two way voice disable to confirm. ☺ A "Happy Tune" sounds. The display confirms the desired two-way voice communication method. 5, 12 E. To Program the Acknowledge Method 18. Two way voice disable or Click the or and press button until the display reads [TEL. ACKNOWLEDGE] to confirm. TEL.ACKNOWLEDGE by single ack 19. TEL.ACKNOWLEDGE by single ack 20. or TEL.ACKNOWLEDGE by all ack The display shows the currently selected option. Click the or button until the display reads the desired acknowledge method, for example, "by all ack". 11 21. Refers to system that is connected to the Voice Box D-304269 KP-250 PG2 User’s Guide 39 6 . Syst e m Configura t ion TEL.ACKNOWLEDGE by all ack ☺ sounds and the display confirms the set acknowledge A "Happy Tune" method. 5, 12 SM S REPORT A. To Program Events to be Reported by SMS 1. SMS REPORT Enter the [USER SETTINGS] menu, select the [SMS REPORT] option and press .1 2. REPORTED EVENTS disabled REPORTED EVENTS disabled 3. or When the display reads [REPORTED EVENTS] press The display shows the currently selected option. Click the or button until the display reads the event group you wish to be reported via SMS, for example, [alarms]. 4 REPORTED EVENTS alarms 4. When you are satisfied with the setting, press REPORTED EVENTS alarms to confirm. A "Happy Tune" ☺ sounds and the display confirms the set events to be reported. 5, 12 B. To Program SMS Telephone Numbers 5. REPORTED EVENTS disabled Click the or button until the display reads the SMS phone number you wish to program or edit, for example, "SMS tel#2", and press or 6. SMS tel#2 7. SMS tel#2 To program or edit the phone number, at the blinking cursor position enter the SMS phone number, for example, “5080168593”, using the numerical keypad. 6, 7 SMS tel#2 A "Happy Tune" 8. When done, press 5080168593 40 to confirm. ☺ sounds and the display confirms the SMS phone number. 8, 12 D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion Additional Information (section B.12) For detailed instructions on how to select User Settings – refer to section A.1 and section A.2. This option allows you to program the events to be reported. To program telephone numbers, click the or button until the display reads the desired option. The display shows the currently selected option (indicated by a the or symbol), for example, "disable report". Using buttons you can now select the events you wish to be reported to private telephones numbers according to the options provided in the tables below: Event Group Option Events to be reported disable report alarms alerts all (-op/cl) op/cl all (-alerts) all No message will be reported Alarm messages only Alert messages only All messages, except arming & disarming Arming and disarming (Open/close) only All messages, except alerts All messages Note: “all” means all events including the L. BAT and AC FAIL trouble messages. The display shows the currently selected option (indicated by a the or symbol), for example, "disable report". Using buttons you can now select the events you wish to be reported to SMS numbers according to the options provided in the table below: Event Group Option Events to be reported disable report alarms alerts all (-op/cl) op/cl all (-alerts) all No message will be reported Alarm messages only Alert messages only All messages, except arming & disarming Arming and disarming (Open/close) only All messages, except alerts All messages The a. b. symbol now appears next to the new selected option. The display shows the phone number currently programmed in this location (for example, 1032759641). The cursor blinks on the first digit of the code. If the location is free the display will be blank ( - - - - ). You can move the cursor to the next or previous location (digit) using the Within the private telephone menu, you can now repeat steps 7 – 9 to program or edit another phone number. Within the SMS menu you can now repeat steps 6 - 8 to program or edit another SMS phone number. You can select between: "1 attempt"; "2 attempts"; "3 attempts"; "4 attempts". 10 You can select between: "enable" – enables 2-way voice communication with private telephones. To end this session and return to previous menu options, press the D-304269 KP-250 PG2 User’s Guide or button. button. 41 6 . Syst e m Configura t ion "disable" - disables 2-way voice communication with private telephones. 11 You can select between: "by single ack" – an acknowledge signal from only a single telephone will stop the reporting process. "by all ack" – an acknowledge signal from all telephones is required to stop the reporting process. 12 You can now, select other options, end this session – (see section A.1 and section A.2), or quit programming (see section A.3). B.1 3 Ena bling / Disa bling t he Squa w k Opt ion The PowerMaster system (and its wireless sirens) can be set to produce a short "Squawk" of audible feedback to assist you when you use your keyfob to arm (1 beep) and disarm (2 beeps) the PowerMaster system (operates in a similar manner to a car alarm). Here you can enable / disable the Squawk. 1. Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. SQUAWK on Enter the [USER SETTINGS] menu, select the [SQUAWK] option and press SQUAWK on The display shows the currently selected setting. 2 2. .1 or Click the or button until the display reads the desired setting, for SQUAWK off example, "off" and press the SQUAWK off A "Happy Tune" button to confirm. 3. ☺ sounds and The display confirms the saved setting. 3, 4 Additional Information (section B.13) For detailed instructions on how to select User Settings – refer to section A.1 and section A.2. a. The display shows the currently selected setting (indicated by a symbol), for example, [SQUAWK on]. The symbol now appears next to the new selected option. You can now select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). b. You can now enable (ON) or disable (OFF) the Squawk option using the 42 or button. D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion B.1 4 Progra m m ing t he Sc he dule r The PowerMaster system includes a PGM output that can be used to open and close an electrically-controlled gate, or to control a preferred electrical device via keyfobs or according to a programmable weekly time schedule. Here you can schedule the PGM output for up to 4 different ON/OFF time activations per any desired day or days of the week. In addition, you can schedule a "Daily" schedule that applies to every day of the week. It is recommended to complete the Scheduler table (placed at the end of this section) before programming the Scheduler. Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. A. To Select the Device No. 1. SCHEDULER Enter the [USER SETTINGS] menu, select the [SCHEDULER] option and press .1 2. PGM When the display reads [PGM], press B. To Set the Day 2 The 1st day of the scheduler is displayed. SUNDAY 3. or Click the or button until the display reads the day you wish to schedule or "Daily", for example, "Tuesday". 2 TUESDAY 4. When the "day" to schedule appears on the display, press C. To Select the Activation No. 5. Operation No 1 or The 1st operation (PGM output activation) of the scheduler is displayed. 3 Click the or button until the display reads the operation you wish to schedule, for example, "operation No 3". Operation No 3 6. When the "operation No." to schedule appears on the display, press D. To Set the ON (Start) Time 7. Start time HH:MM : The "start time" screen is shown on the display. 4 To set the start time of the selected operation, press the D-304269 KP-250 PG2 User’s Guide button. 43 6 . Syst e m Configura t ion 8. Start time HH:MM 10:30 The display shows the current setting of the start time. 5 Start time HH:MM 00:30 Use the numerical keypad to set or change the operation ON (start) time, for example, “00:30”. 6 9. When you are satisfied with the setting, press ☺ Go to step 10 to confirm. ☺ sounds and the display confirms the saved start time. A "Happy Tune" To set the stop time, continue to step 10. E. To Set the OFF (Stop) Time 10. Start time HH:MM 00:30 Click the or button until the display reads "Stop time HH:MM". or 12. Stop time HH:MM 11:45 Stop time HH:MM 16:00 Use the numerical keypad to set or change the operation OFF (stop) time, for example, “16:00”. 6 When you are satisfied with the setting, press to confirm. ☺ sounds and the display confirms the saved stop time. 7 A "Happy Tune" Additional Information (section B.14) For detailed instructions How to select the Setting Options – refer to section A.1 and section A.2. To activate the selected device on every day of the week at the same time(s), use the "Daily" option. Otherwise, use the or buttons to select the specific day (Sunday, Monday, Tuesday…etc) you wish to activate the PGM output. You can later repeat the process for other days of the week. The display shows "operation No 1" which is the first of the 4 ON/OFF time activations you can schedule for the day selected in the previous step. You can later repeat the process for the other 3 activations on the selected day. Here you can select either the "start time" or "stop time" using the minute intervals only. To erase a displayed time, press the or or button. Select the time in 10 button. The screen also displays the selected time format. The display shows the current start or stop time setting of the selected activation with the cursor blinking on the first hour digit. If no time is programmed, the time display will be (00:00). For detailed explanation of how to set the time - refer to Section B.8B. To end this session and return to the previous "operation" menu, press the button. To select other menu options or to quit programming, follow the instructions in sections A.2 and A.3. 44 D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion Scheduler Table Device Device Day Operation 1 Operation 2 Operation 3 Operation 4 Monday ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ ON: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ OFF: _ _: _ _ Description PGM PGM Tuesday PGM Wednesday PGM Thursday PGM Friday PGM Saturday PGM Sunday PGM Daily B.1 5 Ena bling / Disa bling V oic e Opt ion The system allows you to enable or disable status-dependent, pre-recorded verbal messages that are heard over the connected voice box. 1. 2. Here you can enable / disable the Voice Option. Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. VOICE OPTION enable Enter the [USER SETTINGS] menu, select the [VOICE OPTION] option and press VOICE OPTION enable The display shows the currently selected setting. .1 Refers to system that is connected to the Voice Box D-304269 KP-250 PG2 User’s Guide 45 6 . Syst e m Configura t ion or Click the or button until the display reads the desired setting, for example, "disable" and press to confirm. VOICE OPTION disable 3. A "Happy Tune" ☺ sounds and the display confirms the saved setting. 4, 5 Additional Information (section B.15) For detailed instructions on how to select the Setting Options – refer to section A.1 and section A.2. a. The display shows the currently selected setting (indicated by a symbol), for example, "enable". b. You can now enable or disable the voice option using the or button. The symbol now appears next to the newly selected option. You can now select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). If you have selected "enable", make sure that the voice prompts can be heard over the panel loudspeaker by pressing the key on the KP-250 PG2 keypad. B.1 6 Adjust ing t he V olum e of t he Cont rol Pa ne l or Ex t e rna l Box The KP-250 PG2 allows you to adjust the volume of the PowerMaster control panel or an external voice box. 1. Here you can increase or decrease the loudness. Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. PANEL VOLUME 2. Enter the [USER SETTINGS] menu, select the [PANEL VOLUME] option and press PANEL VOLUME .1 or PANEL VOLUME Click the or button repeatedly to increase or decrease the loudness. 3. A "Happy Tune" ☺ sounds and the display confirms the saved setting. Refers to a control panel that is connected to the Voice Box 46 D-304269 KP-250 PG2 User’s Guide 6 . Syst e m Configura t ion Additional Information (section B.16) For detailed instructions on how to select the Setting Options – refer to section A.1 and section A.2. The display shows the currently selected setting (indicated by a symbol). indicates the lowest volume level and indicates the highest. You can now select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). B.1 7 Se ria l N um be r The SERIAL NUMBER menu enables reading the system serial number and similar data for support purposes only. 1. Here you can read the system serial number and other relevant data. Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. SERIAL NUMBER Enter the [USER SETTINGS] menu, select the [SERIAL NUMBER] option and press .1 2. PRODUCT SN 0907030000. Displays the control panel serial number. 3. SW CAT & SN JS702275 K18.022 Displays the control panel software version. 4. LCD CAT SN JS700421 v1.0.02 Displays the control panel keypad software version. 2 5. PANEL ID 100005 Displays the control panel ID for PowerManage connectivity. 6. PYTHON VERSION FFFFFFFFF Displays the GSM image transfer software version. 7. EE CAT & SN J-702271 K18.022 Displays the control panel default version. 8. KP250 SW VER 01.00.09 Displays the KP-250 PG2 keypad software version. D-304269 KP-250 PG2 User’s Guide 47 7 . Adva nc e d Fe a t ure s 9. KP250 cat.number 70245100 Displays the KP-250 PG2 keypad catalog number. 10. RSU VERSION 7S702415 K01.034 Displays the software upgrade communicator version 11. BOOT VERSION 7S702412 K01.022 Displays the software upgrade boot/programmer version Return to step 2 3 4 Additional Information (section B.17) For detailed instructions on how to select the Setting Options – refer to section A.1 and section A.2. Refers to PowerMaster-30 G2 only. To end this session and return to previous menu options, press the button. You can now select another option in the User Settings menu (see section A.1 and section A.2), or quit programming (see section A.3). 7 . Adva nc e d Fe a t ure s Cont rol Opt ions a nd Pushbut t ons The system allows manual or automatic remote control of a device connected to the PGM output. The user defines the ON and OFF times via the Scheduler (see Chapter 6, B.14 Programming the Scheduler). The installer determines which zone sensors will switch the remote controlled appliances on and off. However, the decision whether the remote controlled appliance will respond as programmed is up to you (see next table). Key Function Manual activation of a light or other household electrical appliance that is connected to PGM output. Manual deactivation of a light or other household electrical appliance that is connected to PGM output. Selecting the active automatic control method: Sensors: The appliance is controlled by sensors (assigned by the installer for this). Timer: The appliance is controlled by timer (ON and OFF times are defined by the installer). Both: The appliance is controlled by sensors as well as by a timer. Examples of benefits gained by automatic remote control: Timer Control. When you are away, the timed activation / de-activation of an electrical appliance. Zone Control. Upon disturbance of a perimeter zone, the electrical device is switched on. Note: Automatic activation and deactivation of electrical appliance depends also on the Scheduler setup (see Chapter 6, B.14 Programming the Scheduler). 48 D-304269 KP-250 PG2 User’s Guide 7 . Adva nc e d Fe a t ure s Aut om a t ic ON /OFF Cont rol You can select two of four options: By Timer ON By timer OFF By sensor ON By sensor OFF The presently active options are shown with a dark box ( button. ) at the far right. To view the 2 other options click the A presently inactive option is shown without a dark box at the far right. The dark box will appear if you click the option is displayed. A “Happy Tune” indicates successful saving of a new option. PRESS while RESULTING DISPLAY BY TIMER ON (If this is the default) If not satisfied - press If satisfied - BY TIMER OFF BY TIMER OFF BY TIMER OFF press BY SENSOR ON (If this is the default) BY SENSOR OFF If not satisfied - Press If satisfied - BY SENSOR OFF BY SENSOR OFF HH:MM READY D-304269 KP-250 PG2 User’s Guide 49 8 . Pe riodic T e st by U se r Code PRESS RESULTING DISPLAY 8 . Pe riodic T e st by U se r Code The components of your security system are designed to be maintenance-free as much as possible. Nevertheless, it is mandatory to test the system at least once a week and after an alarm event to verify that all system sirens, detectors, keyfobs, keypads and other peripherals function properly. Proceed as described in this section and if there is any problem, notify your installer at once. The test is performed in three parts: Siren Test: Each siren of the system is automatically activated for 3 seconds (outdoor sirens with low volume). In addition, the system tests the siren of enrolled smoke sensors. Temperature Sensor Test: When Temperature Sensors are enrolled in the system, the KP-250 PG2 displays the temperature of each zone in Celsius or Fahrenheit. Other Device Test: Each of the other devices in the system is activated by the user and the display indicates which devices were not yet tested. The "it's me" indication helps to identify the untested devices if necessary. A counter also indicates the number of devices that remain untested. Carefully read the section titled "Additional Information" according to the indicated references1 etc – see table at end of this section. A. To Enter the Periodic Test Menu 1. HH:MM READY Make sure the system is disarmed and then press the the display reads "PERIODIC TEST" and press button repeatedly until PERIODIC TEST 2. PRESENT TAG OR ENTER CODE: 3. CODE/TAG The screen will now prompt you to enter your user code or present your proximity tag. Enter your User Code or present your proximity tag. 2 3 ☺ Go to step 4 B. To Test the Sirens 4. SIRENS TEST The display now reads [SIREN TEST]. 5. To initiate the siren test press . Immediately after pressing , all 4 LEDs on the panel and all 5 LEDs on the KP-250 PG2 should light (LED test). 4 SIREN Por 50 The display now reads [SIREN P], where "P" indicates the control panel siren that D-304269 KP-250 PG2 User’s Guide 8 . Pe riodic T e st by U se r Code is currently being tested. First the panel siren sounds for 3 seconds after which the PowerMaster system will automatically repeat the procedure for the next siren enrolled in the system until all sirens are tested. 5 You should listen to the sirens sounds and make sure that all sirens sound. Once all the sirens have been tested, the control panel will now test the sirens of smoke sensors that are enrolled in the alarm system. The display now reads [Zxx: SMOKE SIREN] on the first line, and [ ] on the second line, where "Zxx" indicates the zone number of the smoke sensor. During this time, the siren of the tested smoke sensor will sound for up to one minute. Press 6. SIREN TEST ENDED to test the siren of the next smoke sensor. When all the sirens test is complete, the display reads [SIREN TEST ENDED]. Press the or the button to confirm the test and then move to the next step for zone temperature display. or C. To Display the Temperature 7. TEMPERATURE TEST The display now reads [TEMPERATURE TEST]. 8. To display the temperature of zones on the KP-250 PG2, press Z01 +19.5C Z01:Temp. Sensor The KP-250 PG2 reads the temperature of each zone. The display alternates between the temperature, the sensor number and the sensor location. 7 Repeatedly click the Z01 +19.5C Living room 9. DEVICE TESTS END button to review the temperature of each zone (by Temperature Sensor). When the temperature of all zones has been reviewed, the display reads [DEVICE TESTS END]. Press the or .6 or the button to confirm the test and then move to the next step to test the other devices. D. To Test all other Devices TEST ALL DEVICES The display now reads [TEST ALL DEVICES]. 10. To enter the devices test procedure, press 11. NOT ACTIVE NNN The display reads [NOT ACTIVE NNN]. NNN indicates the number of enrolled devices in the panel that have not been tested yet. This number automatically drops one count for every tested device. To initiate devices test, press Z01 NOT ACTIVE st The display shows the 1 device in the list of untested devices. The display D-304269 KP-250 PG2 User’s Guide 51 8 . Pe riodic T e st by U se r Code Z01 CONTACT alternates between the device number, the device type (e.g. magnetic contact, keyfob, keypad, etc.), and the device location. The test is performed by activating each device as explained in point 8 in the table below. Z01 NOT ACTIVE FRONT DOOR Z01 IS ACTIVATE Z01 CONTACT Once the device has been activated, the display will change accordingly. 12. 13. Click DEVICE TESTS END to scroll through the list of all untested devices. 9 When all devices have been activated, the display reads [DEVICE TESTS END] followed by [HH:MM READY]. HH:MM READY Additional Information (Periodic Test) Display shown in disarm state when all zones are secured (00:00 or other digits show present time). If you have not already changed your personal code number, use the default setting – 1111. If the INSTALLER CODE is used to enter the Periodic Test instead of the USER CODE, the devices LED will also provide the link quality indication – refer to Chapter 4 of the KP-250 PG2 Installer’s Guide, Periodic Test by Installer Code. To skip the SIRENS TEST and select the other devices TEST, press The Periodic test can be performed on a maximum of two wireless sirens (including one internal sounder) and the sirens of enrolled smoke sensors. Outdoor sirens are activated with low volume. If no temperature sensor is enrolled in the system, the display reads "NO EXISTING DEV.". The displayed temperature can be in Celsius or Fahrenheit according to the programmed settings of the Temperature Sensor. To activate system devices during the "Periodic Test"; make sure the device LED lights when activated: Contact sensor: Open or close the door or window protected by the contact. Motion sensors: Perform a "walk test" of the detector as explained in the detector's datasheet. Smoke sensors: Perform a "Diagnostic test" as explained in the detector's datasheet. Keyfob: Activate any of the keyfob buttons. Keypads: Other devices: Press the keypad’s button. In general, follow the "Diagnostic Tests" described in the device's datasheet or activate any of its functions. a. Three seconds after the device is displayed, the device LED blinks to assist you to identify ("it's me"). b. To end the session, press the 52 button until the display reads [ TO LEAVE] then press D-304269 KP-250 PG2 User’s Guide 8 . Pe riodic T e st by U se r Code Pe riodic T e st pe r Pa rt it ion In addition to the regular Periodic Test, you can also test zones for enrolled sensors (excluding temperature sensors and sirens) that are assigned to a selected partition. To conduct the periodic Test per Partition 1 HH:MM READY 1. 2. TROUBLE SELECT PARTITION Make sure the selected partition is disarmed and the other partitions are not in exit or entry delay and then press the partition ( When the display reads [SELECT PARTITION], press the partition number of the zones you wish to test, for example, 3. ) button. (Partition 1). PARTITION 1 N.RDY MEMORY PARTITION 1 N.RDY TROUBLE Press the 4. button repeatedly until the display reads [PERIODIC TEST] and press PERIODIC TEST 5. PRESENT TAG OR The screen will now prompt you to or enter your Master user code. 2 ENTER CODE 6. Enter Master user code P1 SENSORS TEST 7. 8. NOT ACTIVE NNN DEVICE TESTS END The display reads [NOT ACTIVE NNN]. NNN indicates the number of enrolled devices in the panel that have not been tested yet. This number automatically drops one count for every tested device. Test per partition is performed by activating each device as explained in point 4 in the Additional Information table below. After a device has been activated, the control panel reads [Zxx IS ACTIVATED] and the "N" indicator drops one count. After all devices have been tested, the control panel reads [DEVICE TESTS END]. D-304269 KP-250 PG2 User’s Guide 53 8 . Pe riodic T e st by U se r Code 9. Press .5 ☺ Return to step 3 Additional Information (Periodic Test per Partition) Partitioning must be enabled by your installer. If you have not already changed your personal code number, use the default setting – 1111. To abort, press the 54 button; the display reads [ TO Exit]. Press the button. To activate system devices during the "Periodic Test"; make sure the device LED lights when activated: Contact sensor: Open or close the door or window protected by the contact. Motion sensors: Perform a "walk test" of the detector as explained in the detector's datasheet. Smoke sensors: Perform a "Diagnostic test" as explained in the detector's datasheet. Periodic test per partition will be interrupted (the panel returns to selected partition display) upon occurrence of one of the following: 1) Disarm event by keyfob, keypad or pendant assigned to a selected partition; 2) PANIC, FIRE or EMERGENCY event. D-304269 KP-250 PG2 User’s Guide 9 . M a int e na nc e 9 . M a int e na nc e Re pla c ing Wire le ss De vic e s Ba t t e rie s The wireless devices supplied with your system are powered by batteries that last several years, in normal use. However, if and when a battery becomes weak, the device itself sends a “low battery” message to the control panel, and a low battery trouble message is displayed together with the zone information (see Chapter 5 – Trouble Indications). The respective manuals of these sensors or devices should be consulted for proper battery replacement guidelines to be performed by the installer. Ac c e ssing 2 4 -H our Z one s To access a sensor defined as a 24-hour zone without causing an alarm: Click - the display will read: USER SETTINGS. Click - the display will read: PRESENT TAG OR ENTER CODE ___. Key your secret 4-digit or present your tag - the buzzer will play the “happy Tune” (- - - ––––). You have 4 minutes during which the 24-hour sensor can be opened and accessed. When the 4 minutes are up, the system will automatically revert to the normal mode. Eve nt Log by U se r Code All events are memorized in an event log that contains up to 100 entries. You can access this log, review the events one by one and draw functional conclusions. Note: Up to 250 (PowerMaster-10 G2) / 1000 (PowerMaster-30 G2 / PowerMaster-33 G2) events are stored in the event log that can be reviewed via the Remote Programmer PC software application or by the remote PowerManage server. If the event log fills up completely, the oldest event is deleted upon registration of each new event. The date and time of occurrence are memorized for each event. When reading the event log, events are shown in chronological order - from the newest to the oldest. The event description is shown with the date and time. The display is shown several times, until you click to move on to an older event, or until the “no action” 4-minute timeout restores the system to the normal operating mode. Access to the event log is provided by clicking the button and then keying your master user code. To get an overall view of using the log, refer to the procedure below. To read the event log, proceed as follows: HH:MM READY 1. PRESENT TAG OR ENTER CODE: 2. CODE KP-250 LIST OF EVENTS When the KP-250 PG2 display reads [PRESENT TAG OR ENTER CODE: enter the current master user code or present your tag. ], The "Happy Tune" will sound and the display will read [KP-250 LIST OF EVENTS]. (see Important Note!) D-304269 KP-250 PG2 User’s Guide 55 9 . M a int e na nc e 3. Click the CPU LOW BATTERY 12/04/11 15:14 F03 DISARM 15/03/11 08:37 4. button. The latest event will be shown. The event is displayed on two rows, for example, "CPU LOW BATTERY" then "12/04/11 15:14". The display will be shown until clicking until the event log times out (4 minutes). Click the again to move to the next event or button as many times as necessary to read all the required data. Important Note! Entering an incorrect code 5 times in a row will initiate a 30second penalty lockout of the keypad. Attention: The system will not allow you to erase the event log. Only the installer is authorized to view and perform this function. Ex it ing t he Eve nt Log 1. Click the button from anywhere within the event log. The display will read [KP-250 TO EXIT]. KP-250 to Exit 2. Click the button. HH:MM READY The system reverts to the normal operating mode. 56 D-304269 KP-250 PG2 User’s Guide APPEN DI X A: Spe c ific a t ions APPEN DI X A: Spe c ific a t ions Frequency Band (MHz) Communication Protocol Battery type Battery Life Expectancy Low Battery Threshold Power source Back light Operating Temperature Humidity Dimensions (WxLxD) Weight (including battery and bracket) Mounting Color Europe and rest of world: 433-434, 868-869 USA: 912-919 PowerG Four 1.5V AA Alkaline batteries 3 years (for typical use). 3.8 V Battery: 4.8VDC – 6VDC AC/DC (optional): 5VDC/2A - 12VDC/1A Blue (keypad) / white (display) 0C to 55C (32F to 131F) Average relative humidity of approx. 75% non-condensing. For 30 days per year, relative humidity may vary from 85% to 95% non-condensing. 150x100x20mm (5-7/8 x 3-7/8 x 13/16 in) 379 g (13 oz). Wall-mounted or desktop White APPEN DI X B: Pa rt it ioning The KP-250 PG2 includes an optional partition feature. Partitioning is available only if your installer has enabled the feature. Once partitioning is enabled Partitioning menus are added to the system which can be viewed on the LCD display. Each user code can be assigned to a combination of up to 3 partitions and each partition can be armed or disarmed regardless of the status of the other partitions within the system. For example, you can define the garage as partition 1, the basement as partition 2, and the house as partition 3. Since each partition is independent of other partitions, you can arm or disarm each partition as desired without altering the states of the other partitions. The system also supports a situation where an area is used by two or more partitions. For example, a reception area which is common to two offices, each of which is assigned to a separate partition, will be armed only after both offices (partitions) are armed. In the armed state the reception area will be disarmed after either office (partitions) has been disarmed to allow the user of that office to use the reception area without generating an alarm. Such an area is termed a "common area". Note: Remote operation is performed per partition, or per user code defined for a particular partition, when partition is enabled. B1 . Se le c t ing a Pa rt it ion When operating in partition mode the first display will read: P1: R Press P2: N P3: R ; the display will read: SELECT PARTITION Press , and to select the desired corresponding partition. Note: After 5 seconds of no button press there will be a timeout and the display will revert to the All Partition display. B2 . Arm ing / Disa rm ing t he Syst e m Before continuing, make sure that Partitioning has been enabled via the Installer Mode. Arming/Disarming All Partitions To arm/disarm all partitions in READY mode, press the D-304269 KP-250 PG2 User’s Guide or button. 57 APPEN DI X B: Pa rt it ioning Arming/Disarming a Single Partition To arm/disarm a single partition, press the or 3. Then, press the or button on the KP-250 PG2 and then press the Partition number: 1; 2; button. B3 . T he Show Func t ion The show function is enabled during single/all partition(s) status and displays information that is relevant to the selected or all partitions. Show All Partitions In Ready mode press memory / status content. Show Single Partition , the display will show information on all partitions. Press repeatedly to view In Ready mode, press and then press the partition number. The display will show information relevant to the selected partition. Press repeatedly to view memory / status content. Note: After 5 seconds of no button press there will be a timeout and the display will revert to the all partition display. B4 . Sire n A partition is alarmed when receiving an event from an alarmed device assigned to that partition. Alarmed devices do not affect partitions to which they are not assigned. A siren is common to all partitions; therefore, an alarm from one or more partitions will activate the siren. Siren Activity The siren will be activated when receiving an event from an alarmed device. Overlapping siren activations from different partitions will not cause the duration of the siren to be extended. When the siren sounds, it will not stop until all alarmed partitions are disarmed. However if the siren is active due to an alarm from a common area zone, and one of the partitions assigned to this area disarms the system, the siren will also stop. In case that the alarm is initiated from a common area but continues with zones that are not assigned to a common area, the siren will not stop until all partitions assigned to the alarmed zones are disarmed. In case of a fire in partition 1 and a burglary in partition 2, the siren will sound FIRE. When partition 1 is disarmed, the siren will sound BURGLAR for the remainder of the siren timeout period. B5 . Pa rt it ion St a t us displa y Partitions status is indicated in the following manner: P1:X P2:X P3:X Each X value indicates a different partition state, as follows: Ready Not ready Away Home Exit delay Entry delay Not used B6 . Com m on Are a s Common areas are areas used as walkthrough zones to areas of 2 or more partitions. There may be more than one common area in an installation depending on the layout of the property. A common area is not the same as a partition; it cannot be armed / disarmed directly. Common areas are created when you assign a zone or zones to 2 or 3 partitions. 58 D-304269 KP-250 PG2 User’s Guide APPEN DI X B: Pa rt it ioning Table A1 summarizes the behavior of the different zone types in a common area. Table A1 – Common Area Definitions Common area zone types Definition Acts as defined only after the last assigned partition is armed AWAY or HOME. In case that one of the partitions is disarmed, an alarm initiated from this zone is ignored for all assigned partitions. Delay zones Delay zones will not trigger an entry delay unless all assigned partitions are armed. It is, therefore, not recommended to define delay zones as common areas. Perimeter follower Act as defined only after the last assigned partition is armed AWAY or HOME. In case that one of the partitions is disarmed, an alarm initiated from this zone is ignored for all assigned partitions. In case that one of the common area assigned partitions is in a delay state (and the other partitions are armed), the alarm will behave as a perimeter follower for this partition only. The event will be ignored for other assigned armed partitions. Acts as defined only after the last assigned partition is armed AWAY. In case that one of the partitions is disarmed or armed HOME, an alarm initiated from this zone is ignored for all assigned partitions. Acts as defined only after the last assigned partition is armed AWAY. In case that one of the partitions is disarmed or armed HOME, an alarm initiated from this zone is ignored for all assigned partitions. In case that one of the common area assigned partitions is in a delay state (and the other partitions are armed), the alarm will behave as an interior follower for this partition only. The event will be ignored for other assigned armed partitions. Acts as a Perimeter-Follower type when all assigned partitions are armed AWAY. Acts as a Delay type when at least one of the assigned partitions is armed HOME. Will be ignored when at least one of the assigned partitions is disarmed. Always armed. Perimeter Interior Interior follower Home / Delay Emergency; Fire; Flood; Gas; Temperature; 24-hour silent; 24-hour audible; Non-alarm D-304269 KP-250 PG2 User’s Guide 59 APPEN DI X C: Glossa ry APPEN DI X C: Glossa ry This list of terms is arranged in alphabetical order. Abort Period: When an alarm is initiated, the internal built-in sounder is activated first for a limited period of time which is the abort period set by the installer. If you cause an alarm accidentally, you can disarm the system within the abort period before the real sirens start and before the alarm is reported to the remote responders. Alarm: There are 2 kinds of alarm: Loud alarm - both internal built-in sounder and external siren blare out constantly and the control panel reports the event by telephone or otherwise. Silent alarm - the sirens remain silent, but the control panel reports the event by telephone or otherwise. A state of alarm is caused by: Motion detected by a motion detector Change of state detected by a magnetic contact detector - a closed window or door is opened Detection of smoke by a smoke detector Tampering with any one of the detectors Pressing the two emergency buttons simultaneously on the panel's keypad. Arming: Arming the alarm system is an action that prepares it to sound an alarm if a zone is “violated” by motion or by opening a door or window, as the case may be. The control panel may be armed in various modes (see AWAY, HOME, INSTANT and LATCHKEY). Assigned: Refers to zones. Associated: Refers to devices. AWAY: This type of arming is used when the protected site is vacated entirely. All zones, interior and perimeter alike, are protected. Bypass: Bypassed zones are zones that are not armed when arming the system. Bypassing permits arming only part of the system while allowing free movement of people within certain zones when the system is armed. Chime Zones: Allow you to keep track of activity in the protected area while the alarm system is in the disarmed state. Whenever a chime zone is "opened", the buzzer beeps twice. The buzzer doesn't beep, however, upon closing the zone (return to normal). Residences can use this feature to annunciate visitors. Businesses can use it to signal when customers enter the premises or when personnel enter restricted areas. Note: A 24-hour zone or a fire zone should not be designated as a chime zone, because both zone types actuate an alarm if disturbed while the system is in the disarmed state. Although one zone or more are designated as chime zones, you can still enable or disable the chime function using the chime ON/OFF button and .LED Control Panel: The control panel is a cabinet that incorporates the electronic circuitry and microprocessor that control the alarm system. It collects information from various sensors, processes it and responds in various ways. It also includes the user-interface - control keys, numerical keypad, display, sounder and loudspeaker. Default Settings: Settings that are applicable to a specific device group. Detector: The device (apparatus) that sends an alarm, that communicates with the control panel (e.g. NEXT PG2 is a motion detector, SMD-426 PG2 is a smoke detector) Disarming: The opposite of arming - an action that restores the control panel to the normal standby state. In this state, only fire and 24-hour zones will sound an alarm if violated, but an “emergency alarm” may also be initiated. Disturbed Zone: A zone in a state of alarm (this may be caused by an open window or door or by motion in the field of view of a motion detector). A disturbed zone is considered “not secured”. 60 D-304269 KP-250 PG2 User’s Guide APPEN DI X C: Glossa ry Forced Arming: When any one of the system zones is disturbed (open), the alarm system cannot be armed. One way to solve this problem is to find and eliminate the cause for zone disturbance (closing doors and windows). Another way to deal with this is to impose forced arming - automatic de-activation of zones that are still disturbed upon termination of the exit delay. Bypassed zones will not be protected throughout the arming period. Even if restored to normal (closed), bypassed zones will remain unprotected until the system is disarmed. Permission to “force arm” is given or denied by the installer while programming the system. HOME: This type of arming is used when people are present within the protected site. A classic example is night-time at home, when the family is about to retire to bed. With HOME arming, perimeter zones are protected but interior zones are not. Consequently, motion within interior zones will be ignored by the control panel, but disturbance of a perimeter zone will cause an alarm. Instant: You can arm the system AWAY-INSTANT or HOME-INSTANT, thereby canceling the entry delay for all delay zones for the duration of one arming period. For example, you may arm the control panel in the HOME-INSTANT mode and remain within the protected area. Only perimeter protection is active, and if you do not expect somebody to drop in while the system is armed, alarm upon entry via the main door is an advantage. To disarm the system without causing an alarm, use your control keypad (which is normally accessible without disturbing a perimeter zone) or use a keyfob transmitter. It's me: The KP-250 PG2 system includes a powerful device locator that helps you to identify the actual device displayed on the LCD, as follows: While the LCD displays a zone (device), the LED on the respective device flashes indicating "it's me". The "it's me" indication appears after a certain time delay (max. 16 seconds) and will last for as long as the LCD displays the device with a timeout of 2 minutes. Latchkey: The Latchkey mode is a special arming mode in which designated "latchkey users" will trigger a "latchkey message" to be sent to a telephone when they disarm the system. For example, if parents want to be sure that their child has returned from school and disarmed the system. Latchkey arming is only possible when the system is armed in the AWAY mode. Magnetic Contact Sensor: A Magnet-controlled switch and a wireless transmitter in a shared housing. The sensor is mounted on doors and windows to detect changes in state (from closed to open and vice versa). Upon sensing that a door or window is open, the sensor transmits an “alarm” signal to the control panel. The control panel, if not armed at that time, will consider the alarm system as “not ready for arming” until the door or window is secured and the panel receives a “restored” signal from the same sensor. Motion Sensor: A passive Infrared motion sensor. Upon sensing motion, the sensor transmits an alarm signal to the control panel. After transmission, it stands by to sense further motion. Non-Alarm Zone: Your installer can designate a zone for roles other than alarm. For instance, a motion sensor installed in a dark stairway may be used to switch on lights automatically when someone crosses the dark area. Another example is a miniature wireless transmitter linked to a zone that controls a gate opening mechanism. Quick Arming: Arming without a user code. The control panel does not request your user code when you press one of the arming buttons. Permission to use this arming method is given or denied by the installer while programming the system. Remote Responder: A responder can be either a professional service provider to which the home or business owner subscribes (a monitoring station) or a family relation/friend who agrees to look after the protected site during absence of its occupants. The control panel reports events by telephone to both kinds of responders. Restore: When a detector reverts from the state of alarm to the normal standby state, it is said to have been “restored”. A motion detector restores automatically after detection of movement, and becomes ready to detect again. A magnetic contact detector restores only upon closure of the protected door or window. Sensor: The sensing element: pyroelectric sensor, photo-diode, microphone, smoke optical sensor etc. Smoke Detector, Wireless: A regular smoke detector and a wireless PowerG transceiver in a shared housing. Upon detection of smoke, the detector transmits its unique identification code accompanied by an alarm signal and various status signals to the control panel. Since the smoke detector is linked to a special fire zone, a fire alarm is initiated. State: AWAY, HOME, AWAY-INSTANT, HOME-INSTANT, LATCHKEY, FORCED, BYPASS. Status: AC fail, low battery, trouble, system state etc. User Codes: The KP-250 PG2 is designed to obey your commands, provided that they are preceded by a valid security access code. Unauthorized people do not know this code, so any attempt on their part to disarm or defeat the system is bound to fail. Some operations, however, can be carried out without a user code as they do not degrade the security D-304269 KP-250 PG2 User’s Guide 61 APPEN DI X C: Glossa ry level of the alarm system. Zone: A zone is an area within the protected site under supervision of a specific detector. During programming, the installer allows the control panel to learn the detector’s identity code and links it to the desired zone. Since the zone is distinguished by number and name, the control panel can report the zone status to the user and register in its memory all the events reported by the zone detector. Instant and delay zones are “on watch” only when the control panel is armed, and other (24hour) zones are “on watch” regardless of whether the system is armed or not. 62 D-304269 KP-250 PG2 User’s Guide APPEN DI X D: Com plia nc e w it h St a nda rds APPEN DI X D: Com plia nc e w it h St a nda rds Designed to comply with Standards Europe: EN 300220-1, EN 300220-2, EN300330, EN301489, EN60950, EN50131-1, EN50131-3, EN50131-6. The KP-250 PG2 is compatible with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 and EN50131-1 Grade 2 Class II. USA: CFR 47 part 15 Canada: RSS 210 UK: This product is suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and environmental class 2. DD243 and BS8243. Sweden: SSF 1014 RFID Tags: ISO-18000-2 (125 kHz) The Power G peripheral devices have two- way communication functionality, providing additional benefits as described in the technical brochure. This functionality has not been tested to comply with the respective technical requirements and should therefore be considered outside the scope of the product’s certification EN 50131-1 Security Grade Grade 2 EN 50131-1 Environmental Class Class 2 This device complies with FCC Rules Part 15 and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. WARNING! To comply with FCC and IC RF exposure compliance requirements, the mobile version of this device should be located at a distance of at least 20 cm from all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other antenna or transmitter. Le dispositif doit être placé à une distance d'au moins 20 cm à partir de toutes les personnes au cours de son fonctionnement normal. Les antennes utilisées pour ce produit ne doivent pas être situés ou exploités conjointement avec une autre antenne ou transmetteur. The digital circuit of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: – Re-orient or re-locate the receiving antenna. – Increase the distance between the device and the receiver. – Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. – Consult the dealer or an experienced radio/TV technician. Changes or modifications not expressly approved by Visonic Ltd. could void the user's authority to operate the equipment. W.E.E.E. Product Recycling Declaration For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste. Directive 2002/96/EC Waste Electrical and Electronic Equipment. D-304269 KP-250 PG2 User’s Guide 63 WARRANTY Visonic Limited (the “Manufacturer") warrants this product only (the "Product") to the original purchaser only (the “Purchaser”) against defective workmanship and materials under normal use of the Product for a period of twelve (12) months from the date of shipment by the Manufacturer. This Warranty is absolutely conditional upon the Product having been properly installed, maintained and operated under conditions of normal use in accordance with the Manufacturers recommended installation and operation instructions. Products which have become defective for any other reason, according to the Manufacturers discretion, such as improper installation, failure to follow recommended installation and operational instructions, neglect, willful damage, misuse or vandalism, accidental damage, alteration or tampering, or repair by anyone other than the manufacturer, are not covered by this Warranty. The Manufacturer does not represent that this Product may not be compromised and/or circumvented or that the Product will prevent any death and/or personal injury and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all cases provide adequate warning or protection. The Product, properly installed and maintained, only reduces the risk of such events without warning and it is not a guarantee or insurance that such events will not occur. THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS OR LIABILITIES, WHETHER WRITTEN, ORAL, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE. IN NO CASE SHALL THE MANUFACTURER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER, AS AFORESAID. THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES OR FOR LOSS, DAMAGE, OR EXPENSE, INCLUDING LOSS OF USE, PROFITS, REVENUE, OR GOODWILL, DIRECTLY OR INDIRECTLY ARISING FROM PURCHASER’S USE OR INABILITY TO USE THE PRODUCT, OR FOR LOSS OR DESTRUCTION OF OTHER PROPERTY OR FROM ANY OTHER CAUSE, EVEN IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH, PERSONAL AND/OR BODILY INJURY AND/OR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHERWISE, BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION. KP-250 PG2 User’s Guide, D-304269 64 However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty, THE MANUFACTURER'S MAXIMUM LIABILITY (IF ANY) SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the Manufacturer. When accepting the delivery of the Product, the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed of. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so these limitations may not apply under certain circumstances. The Manufacturer shall be under no liability whatsoever arising out of the corruption and/or malfunctioning of any telecommunication or electronic equipment or any programs. The Manufacturers obligations under this Warranty are limited solely to repair and/or replace at the Manufacturer’s discretion any Product or part thereof that may prove defective. Any repair and/or replacement shall not extend the original Warranty period. The Manufacturer shall not be responsible for dismantling and/or reinstallation costs. To exercise this Warranty the Product must be returned to the Manufacturer freight pre-paid and insured. All freight and insurance costs are the responsibility of the Purchaser and are not included in this Warranty. This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to act on its behalf in the modification, variation or extension of this warranty. This warranty shall apply to the Product only. All products, accessories or attachments of others used in conjunction with the Product, including batteries, shall be covered solely by their own warranty, if any. The Manufacturer shall not be liable for any damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or otherwise, caused by the malfunction of the Product due to products, accessories, or attachments of others, including batteries, used in conjunction with the Products. This Warranty is exclusive to the original Purchaser and is not assignable. This Warranty is in addition to and does not affect your legal rights. Any provision in this warranty which is contrary to the Law in the state or country were the Product is supplied shall not apply. Warning: The user must follow the Manufacturer’s installation and operational instructions including testing the Product and its whole system at least once a week and to take all necessary precautions for his/her safety and the protection of his/her property. 1/08 (Rev 1, 8/14) D-304269 KP-250 PG2 User’s Guide
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract Create Date : 2014:09:30 16:14:22+03:00 Modify Date : 2014:09:30 16:15:41+03:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2014:09:30 16:15:41+03:00 Producer : Acrobat Distiller 10.1.8 (Windows) Format : application/pdf Title : untitled Document ID : uuid:92848d47-5aff-4834-bb79-7e6d5e88b73d Instance ID : uuid:2ce23b65-124b-450a-be85-29aee112cc87 Page Count : 64EXIF Metadata provided by EXIF.tools