Welch Allyn WAM2500 Wireless Acquisition Module User Manual 5 Appendix A

Mortara Instrument Inc Wireless Acquisition Module 5 Appendix A

5 Appendix A

MESSAGES AND INFORMATION APPENDIX A  21 The following table describes messages that are displayed on the WAM during patient hookup and transmission.  Table of Messages  Message Solution Solid Green LED No interaction required Flashing Green LED Replace AA battery Solid Yellow LED Lead fail message, check leads for proper connection Flashing Yellow LED Low battery and lead fail condition exist. Replace battery and check leads for proper connection LED Off Power is off press power button to turn on. If no audible beeping is heard, battery is completely depleted replace battery on power on WAM. If beeping is heard assure you are within 3 meters of the electrocardiograph.  Following Message’s will be seen on the ELI 350 if applicable RA or N RA or N fail.  Check if the lead wire is off or the electrode needs to be replaced. RL or R RL or R fail.  Check if the lead wire is off or the electrode needs to be replaced. LA or F LA or F fail.  Check if the lead wire is off or the electrode needs to be replaced. LL or L LL or L fail.  Check if the lead wire is off or the electrode needs to be replaced. A combination of  RA/…/LL or N…F More than one limb lead fail or all leads fail.  Check the lead wires and electrodes. V1 or C1 V/C1 fail.  Check if the lead wire is off or the electrode needs to be replaced. V2 or C2 V/C2 fail.  Check if the lead wire is off or the electrode needs to be replaced. V3 or C3 V/C3 fail.  Check if the lead wire is off or the electrode needs to be replaced. V4 or C4 V/C4 fail.  Check if the lead wire is off or the electrode needs to be replaced. V5 or C5 V/C5 fail.  Check if the lead wire is off or the electrode needs to be replaced. V6 or C6 V/C6 fail.  Check if the lead wire is off or the electrode needs to be replaced. A combination of V1, V2, V3, V4, V5, V6 or C1, C2, C3, C4, C5, C6 More than one chest lead fails.  Check the lead wires and electrodes. Note:  Lead Wire messages will be seen on the ELI 350 display and not on the WAM.  The WAM will display a yellow LED in the event of a lead failure.
 APPENDIX A  22 The following system information log is provided for your convenience.  You need this information if your device needs servicing.  Be sure to update the information log when you add options or your device has been serviced.  Record the model and serial number of all components, dates of removal and/or replacement, and the name of the vendor from whom the component was purchased and/or installed.  In addition to having records of this information, the system information log provides a warranty record of when your device was placed in service.  System Information Log  Manufacturer:  Mortara Instrument, Inc. 7865 N. 86th St. Milwaukee, WI 53224    Product Information:           Telephone Numbers:  USA:  800-231-7437 European:  +39-51-6650-701  Sales Department:  800-231-7437 Service Department:  888-MORTARA   Name of Unit/Product: ____________________________  Date of Purchase: ___/___/_____  Purchased Unit From: _____________________________  Serial Number: __________________________________  Software Version: ________________________________   Serial and Part Number Location  For questions and service information, have both serial and part number available when calling.  The model type, serial number (SN), and part number (REF) are found on the back label of the device similar to the one pictured below.

Navigation menu