Welch Allyn WAM2500 Wireless Acquisition Module User Manual 5 Appendix A
Mortara Instrument Inc Wireless Acquisition Module 5 Appendix A
Contents
5 Appendix A
MESSAGES AND INFORMATION APPENDI X A The following table describes messages that are displayed on the WAM during patient hookup and transmission. Table of Messages Message Solid Green LED Flashing Green LED Solid Yellow LED Flashing Yellow LED LED Off Solution No interaction required Replace AA battery Lead fail message, check leads for proper connection Low battery and lead fail condition exist. Replace battery and check leads for proper connection Power is off press power button to turn on. If no audible beeping is heard, battery is completely depleted replace battery on power on WAM. If beeping is heard assure you are within 3 meters of the electrocardiograph. Following Message’s will be seen on the ELI 350 if applicable RA or N RA or N fail. Check if the lead wire is off or the electrode needs to be replaced. RL or R RL or R fail. Check if the lead wire is off or the electrode needs to be replaced. LA or F LA or F fail. Check if the lead wire is off or the electrode needs to be replaced. LL or L LL or L fail. Check if the lead wire is off or the electrode needs to be replaced. A combination of RA/…/LL or N…F More than one limb lead fail or all leads fail. Check the lead wires and electrodes. V1 or C1 V/C1 fail. Check if the lead wire is off or the electrode needs to be replaced. V2 or C2 V/C2 fail. Check if the lead wire is off or the electrode needs to be replaced. V3 or C3 V/C3 fail. Check if the lead wire is off or the electrode needs to be replaced. V4 or C4 V/C4 fail. Check if the lead wire is off or the electrode needs to be replaced. V5 or C5 V/C5 fail. Check if the lead wire is off or the electrode needs to be replaced. V6 or C6 V/C6 fail. Check if the lead wire is off or the electrode needs to be replaced. More than one chest lead fails. Check the lead wires and electrodes. A combination of V1, V2, V3, V4, V5, V6 or C1, C2, C3, C4, C5, C6 Note: Lead Wire messages will be seen on the ELI 350 display and not on the WAM. The WAM will display a yellow LED in the event of a lead failure. 21 APPENDI X A The following system information log is provided for your convenience. You need this information if your device needs servicing. Be sure to update the information log when you add options or your device has been serviced. Record the model and serial number of all components, dates of removal and/or replacement, and the name of the vendor from whom the component was purchased and/or installed. In addition to having records of this information, the system information log provides a warranty record of when your device was placed in service. System Information Log Manufacturer: Telephone Numbers: Mortara Instrument, Inc. 7865 N. 86th St. Milwaukee, WI 53224 USA: 800-231-7437 European: +39-51-6650-701 Sales Department: 800-231-7437 Service Department: 888-MORTARA Product Information: Name of Unit/Product: ____________________________ Date of Purchase: ___/___/_____ Purchased Unit From: _____________________________ Serial Number: __________________________________ Software Version: ________________________________ Serial and Part Number Location For questions and service information, have both serial and part number available when calling. The model type, serial number (SN), and part number (REF) are found on the back label of the device similar to the one pictured below. 22
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf Linearized : No Create Date : 2009:04:01 19:54:13 Modify Date : 0000:01:01 00:00:00 Producer : PDF Complete version 3.0.31.1 Title : Microsoft Word - 5-Appendix A.doc Page Count : 2 PDF Version : 1.4EXIF Metadata provided by EXIF.tools