Welch Allyn WAM2500 Wireless Acquisition Module User Manual 2 Section 1
Mortara Instrument Inc Wireless Acquisition Module 2 Section 1
Contents
- 1. 3 Sction 2 Manual
- 2. 2 Section Manual
- 3. 1 Cover Manual
- 4. 4 Section 3 Manual
- 5. 5 Appendix A
2 Section Manual
INTRODUCT ION SECTION 1 Manual Purpose The WAM (Wireless Patient Cable) user manual explains how to: · · · · Acquire and transmit 12-lead ECG signals to a receiving device Acquire and transmit 12-lead Rhythm strip to a receiving device Power the WAM On and Off LED Messages / Buzzer Beep Tone o Power On/Off o RF communication link status o Low Battery Warning o Lead check Audience This manual is written for clinical professionals who are expected to have a working knowledge of medical procedures and terminology as required for monitoring and/or acquiring clinical data from cardiac patients. Indications for Use The WAM cable is a non-invasive prescription device: · Indicated for use as a radiofrequency physiological signal transmitter that acquires and delivers RF transmission of real-time electrocardiographic data obtained during resting/physiologic electrocardiographic testing. · Indicated for use in a clinical setting, by qualified medical professionals, properly trained for acquiring ECG data and use of the system. The personnel must be experienced in cardiovascular problematic situations and emergency procedures or pathologies related to cardiac involvements. It is not intended as a sole means of diagnosis. · Indicated for use in hospital and physicians office, patients of any age where ECG acquisition is done (e.g., patients in Coronary Care Units, Step-Down Units, Emergency Departments, clinics, physicians offices, sports medicine facilities or rehabilitation departments). · It is not designed for use in highly invasive environments, such as an operating theatre. The cardiac data and analysis provided is reviewed, confirmed, and used by trained medical personnel in the diagnosis of patients with various cardiac rhythm patterns. System Description The WAM incorporates wireless electrocardiographic technology to achieve the real-time acquisition and RF transmission of simultaneous 12-lead ECG data with diagnostic quality. Transmission to a Mortara receiver module allows the cardiac signals to be displayed on a monitoring device such as an electrocardiograph without the need for a direct connection to an electrocardiograph. The WAM uses a single AA battery. SECTION 1 The following equipment is necessary to use the WAM: · · · One AA battery, 1.5V Mortara receiver module in the electrocardiograph ECG cable WAM with ECG Cable Figure 1-1, Front View ECG Patient Cable Power On/Off LED Indicator 12 Lead ECG Acquisition Rhythm Print Battery Compartment SECTION 1 Part Numbers Description Wireless Patient Cable WAM Battery Cap Assembly WAM Carrying Pouch with Belt COMBINER REPLACEMENT WAM LEADS 5 POSITION Plastic part “combines” 5 leads into a groups for plugging into the WAM LEAD SET WAM 10 WIRE BANANA AHA Full set of 10 wires, grouped into two sets of 5, with “combiners” LEAD SET WAM 10 WIRE BANANA IEC ll set of 10 wires, grouped into two sets of 5, with “combiners” REPLACEMENT LEAD SET WAM LIMBS BANANA AHA Indicated leads, no combiners REPLACEMENT LEAD SET WAM LIMBS BANANA IEC Indicated leads, no combiners REPLACEMENT LEAD SET WAM V1-V3 BANANA AHA Indicated leads, no combiners REPLACEMENT LEAD SET WAM C1-C3 BANANA IEC Indicated leads, no combiners REPLACEMENT LEAD SET WAM V4-V6 BANANA AHA Indicated leads, no combiners REPLACEMENT LEAD SET WAM C4-C6 BANANA IEC Indicated leads, no combiners LEAD SET WAM 10 WIRE CLIPS AHA Full set of 10 wires, grouped into two sets of 5, with “combiners” LEAD SET WAM 10 WIRE CLIPS IEC Full set of 10 wires, grouped into two sets of 5, with “combiners” REPLACEMENT LEAD SET WAM LIMBS CLIPS AHA Indicated leads, no combiners REPLACEMENT LEAD SET WAM LIMBS CLIPS IEC Indicated leads, no combiners REPLACEMENT LEAD SET WAM V1-V3 CLIPS AHA Indicated leads, no combiners REPLACEMENT LEAD SET WAM C1-C3 CLIPS IEC Indicated leads, no combiners REPLACEMENT LEAD SET WAM V4-V6 CLIPS AHA Indicated leads, no combiners REPLACEMENT LEAD SET WAM C4-C6 CLIPS IEC Indicated leads, no combiners WAM User Manual (XXX=language) WAM Short-Form Instruction Card (XXX=language) Case of 24 Monitoring Hookup Kits: · 10 monitoring electrodes · 1 abrasive pad · 1 gauze wipe · 1 razor · 2 alcohol prep pads Part Numbers WAM-XXX-XXXXX 8356-008-51 8485-025-50 9293-046-01 9293-046-50 9293-046-51 9293-046-52 9293-046-53 9293-046-54 9293-046-55 9293-046-56 9293-046-57 9293-047-50 9293-047-51 9293-047-52 9293-047-53 9293-047-54 9293-047-55 9293-047-56 9293-047-57 9515-XXX-XX-XXX 9503-XXX-XX-XXX 9294-009-51 SECTION 1 Approved Battery Models Description Alkaline, AA-type, 1.5V Lithium, AA-type, 1.5V Manufacturer Various Energizer Part Numbers Various L91 NOTE: Replace cells with only those listed above. Use of other cells may present a risk of fire or explosion. To order additional supplies, contact a Mortara Instrument customer service representative at: Mortara Instrument, Inc. 7865 N. 86th Street Milwaukee, WI 53224 Tel: 1.888.MORTARA (667.8272) Fax: 414.354.4760 Internet: http://www.mortara.com Specifications Feature Specifications Instrument Type 12-lead ECG digital transmitter cable Input Channels Continuous 12-lead signal acquisition and transmission ECG Leads Transmitted I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5 and V6 Special Functions Defibrillator Protection Power On/Off, Lead impedance check, during hookup, lead fail, and battery notification 2400-2483 MHz interference immune proprietary frequency hopping scheme Electronics protected from water damage; meets EN 60529 rating IPX1 Complies with AAMI standards and IEC 60601-2-25 Function Keys On/Off, 12-Lead ECG acquisition, Rhythm acquisition Device Classification Type CF (ECG), battery operated Weight 6.7 oz. (190 g) with battery Dimensions 4.45” x 4.25” x 1.1” (11.3 cm x 10.8 cm x 2.79 cm) Battery 1 AA alkaline, 24-hour typical life RF Protocol Water Resistance NOTE: Operating range performance is 3 meters or 10 feet with.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf Linearized : No Create Date : 2009:04:01 19:48:39 Modify Date : 0000:01:01 00:00:00 Producer : PDF Complete version 3.0.31.1 Title : Microsoft Word - 2-Section 1.doc Page Count : 4 PDF Version : 1.4EXIF Metadata provided by EXIF.tools