Yaesu Musen 20461X50 Scanning Receiver User Manual FTDX3000 Operating Manual

Yaesu Musen Co., Ltd. Scanning Receiver FTDX3000 Operating Manual

Users Manual 4

Download: Yaesu Musen 20461X50 Scanning Receiver User Manual FTDX3000 Operating Manual
Mirror Download [FCC.gov]Yaesu Musen 20461X50 Scanning Receiver User Manual FTDX3000 Operating Manual
Document ID1770289
Application IDCuUODe+YEoS/EzTMH+3/8g==
Document DescriptionUsers Manual 4
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize230.45kB (2880650 bits)
Date Submitted2012-08-20 00:00:00
Date Available2013-02-16 00:00:00
Creation Date2012-08-02 15:47:09
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2012-08-10 18:56:28
Document TitleFTDX3000_Operating_Manual
Document CreatorAdobe InDesign CS4_J (6.0.6)
Document Author: YAESU MUSEN CO., LTD.

Basic Operation:Receiving on Amateur Bands
FCC ID: K6620461X50 / IC: 511B-20461X50
Operation on 60-Meter (5 MHz) Band (U.S. and U.K. version only)
The recently-released 60-meter band is covered, in the FT DX 3000, by fixed memory channels. These channels are set
to USB, and they appear between the “last” PMS channel (“P9U”) and the first “regular” memory channel (Channel 1):
1. Press the [V/M] button once to enter the “Memory”
mode; the “MCH” icon will appear in the display
and a memory channel number will appear on the
display.
Advice:
If you can not enter the “Memory” mode, check to
see if the transceiver is in VFO-B mode (the green
[(VFO-B)RX] Indicator/Switch is illuminated). If so,
press the [(VFO-A)RX] Indicator/Switch to return
operation to VFO-A. Now, press the [V/M] button to
enter the “Memory” mode.
2. Press the [MCH] button located on the bottom right
of the [CLAR/VFO-B] knob. The LED imbedded in
the button will glow orange to signify that rotation of
the [CLAR/VFO-B] knob will allow selection of the
memory channel.
3. Memory channels (“5M-01” through “5M-10”) are
pre-programmed, at the factory, with the permitted
frequencies in the 5 MHz band, and the USB mode
is automatically selected on these channels.
4. To exit from 60-meter operation and return to the
VFO mode, just press the [V/M] button.
[VFO-A(RX)] Button
[CLAR/VFO-B] Knob
[VFO-B(RX)] Button
Main Tuning Dial Knob
[MCH] Button
[V/M] Button
Channel Number
5M-01
5M-02
5M-03
5M-04
5M-05
5M-06
5M-07
5M-08
5M-09
5M-10
FREQUENCY
5.332000 MHz
5.348000 MHz
5.358500 MHz
5.373000 MHz
5.405000 MHz
5.332000 MHz
5.348000 MHz
5.358500 MHz
5.373000 MHz
5.405000 MHz
Note:
The frequencies and operating mode for 5 MHz band
operation are fixed, and may not be changed.
Page 34
FT DX 3000 Operating Manual
Basic Operation:Receiving on Amateur Bands
FCC ID: K6620461X50 / IC: 511B-20461X50
CLAR (Clarifier) Operation
The [RX CLAR], [TX CLAR], [CLEAR] buttons and [CLAR/VFO-B] knob are used to offset the receive frequency,
the transmit frequency, or both, from their settings on the VFO-A frequency. Four small numbers on the Multi-Display
Window show the current Clarifier offset. The Clarifier controls on the FT DX 3000 are designed to allow you to preset
an offset (up to ±9.999 kHz) without actually retuning, and then to activate it via the Clarifier’s [RX CLAR] and [TX
CLAR] buttons. This feature is ideal for following a drifting station, or for setting small frequency offsets sometimes
utilized in DX “Split” work.
Here is the technique for utilizing the Clarifier:
1. Press the [RX CLAR] button. In the Multi-Display
Window, the “RX” notation will appear, and the
programmed offset will be applied to the receive frequency.
2. Rotation of the [CLAR/VFO-B ] knob will allow
you to modify your initial offset on the fly. Offsets of
up to ±9.99 kHz may be set using the Clarifier.
[CLEAR] Button
[TX CLAR] Button
Multi-Display Window [RX CLAR] Button
To cancel Clarifier operation, press the [RX CLAR] button. The “RX” notation will disappear from the display.
Advice:
 Turning the Clarifier off simply cancels the application of the programmed offset from the receive and/
or the transmit frequencies. To clear the Clarifier
offset, and reset it to “zero,” press the [CLEAR] button. The programmed offset is displayed in the small
multi-channel window of the frequency display.
 You may also activate the clarifier on the VFO-B frequency. In this case, the offset frequency is set using
the Main Tuning Dial knob, instead of the [CLAR/
VFO-B] knob.
 The Clarifier operation (including the offset frequency) will be memorized independently on each VFO
stack of VFO-A and VFO-B.
[CLAR/VFO-B] Knob
TXCLAR
Alternately, You may apply the Clarifier offset
to the transmit frequency, without changing the
receive frequency (typically, for “split” DX pileups).
The Tuning Offset Indicator provides a graphical representation of the Clarifier offset.
In the factory default setting On CW, the Tuning Offset Indicator is used for CW Center Tuning, instead of Clarifier Offset. If you wish to change this so that the Clarifier
Offset is also displayed on CW, use the following procedure:
1. Press and hold in the [MENU ] button for one
second to enter the Menu mode.
2. Rotate the [CLAR/VFO-B] knob or p/q button
to select Menu item “011 DISPLAY BAR DISPLAY SELECT”.
3. Press the [ SELECT ] button then rotate the
[CLAR/VFO-B] knob or p/q button to select
“CLAR (Clarifier)” (replacing the default “CW
TUNE (CW TUNING)” selection).
4. Press the [ SELECT ] button, then press the
[MENU] button to save the new setting and exit
to normal operation.
[Zero Offset]
[Minus (–) Offset]
[MENU] button [SELECT] button
[p/q] Button
FT DX 3000 Operating Manual
[Plus (+) Offset]
[CLAR/VFO-B] Knob
Page 35
Basic Operation:Receiving on Amateur Bands
FCC ID: K6620461X50 / IC: 511B-20461X50
LOCK
You may lock the setting of the Main Tuning Dial knob (for VFO-A frequency tuning) and the [CLAR/VFO-B] knob (for
VFO-B frequency tuning), to prevent accidental frequency change.
Main Tuning Dial knob Lock
[TX CLAR(LOCK)] Button
To lock the Main Tuning Dial knob, press the [(VFO-A)
RX] Indicator/Switch to illuminate the imbedded green
LED, then press the [LOCK] button that is located to
the right of the Main Tuning Dial knob. To unlock the
Dial setting, and restore normal tuning, press the [LOCK]
button once more.
[CLAR/VFO-B] knob Lock
[LOCK] Button
To lock the [CLAR/VFO-B] knob, press the [VFO-B/
CLAR] button that is located to the right of the [CLAR/
VFO-B] knob. Indicator/Switch to illuminate the imbedded orange LED, then press the [TX CLAR (LOCK)]
button that is located to the top of the [CLAR/VFO-B]
knob. To unlock the [CLAR/VFO-B] knob, and restore
normal tuning, press the [TX CLAR (LOCK)] button
once more.
[VFO-B/CLAR] Button
Advice:
The lock feature will be memorized independently on
each Main Tuning Dial knob and the [CLAR/VFO-B]
knob.
DIMMER
The illumination level of the display may be adjusted via Menu item “005 DISP DIM VFD”.
To adjust the illumination level:
1. Press and hold in the [MENU] button for one second
to enter the Menu mode.
2. Rotate the [CLAR/VFO-B] knob or p/q button to
select Menu item “010 DISPLAY DIMMER TFT”.
3. Press the [SELECT] button then rotate the [CLAR/
VFO-B] knob or p/q button to select the desired
illumination level.
4. Press the [SELECT] button, then press the [MENU]
button to save the new setting and exit to normal operation.
Page 36
[MENU] button [SELECT] button
[p/q] Button
[CLAR/VFO-B] Knob
FT DX 3000 Operating Manual
Convenience Features
FCC ID: K6620461X50 / IC: 511B-20461X50
Using the VFO-B
VFO-B operates similar to VFO-A, which you should
be familiar with by now. However, the [CLAR/VFO-B]
knob, instead of the Main Tuning Dial knob selects the
frequency for VFO-B (See box below for tuning rate).
The two VFOs make simple transmit/receive split frequency operation possible. Use various combinations
of the four VFO red and green transmit and receive
switches to set up split frequency operation. The [SPLIT]
button also sets up split frequency operation. See page
69 for details about Split-Frequency Operation.
Main Tuning Dial Knob
[AB] Button
[A
B] Button
[CLAR/VFO-B] Knob
The frequency and mode data can be transferred from
VFO-A to VFO-B by pressing the [AB] button, don’t
forget that this will overwrite any settings that were in
VFO-B previously. Also, the contents of the two VFOs
can be swapped (with no loss of data) by pressing the
[AB] button.
Most of the interference reduction features, which are
described later, can also be used on VFO-B.
Two things you cannot do with VFO-B that you can do
with VFO-A, are store the contents of VFO-B directly
into a memory, and set the Clarifier offset. For these
functions you need to swap the VFO-B with the VFO-A
by pressing the [AB] button, then store the contents
into the memory or set the Clarifier.
[CLAR/VFO-B] Knob Tuning Rate
Operating Mode
1 step
1 dial rotation
Normal [Fast]
Normal [Fast]
LSB/USB/CW/AM/ 10 Hz
2 kHz
[100 Hz]
[20 kHz]
RTTY/PKT(LSB)
FM/PKT(FM)
100 Hz [1 kHz] 20 kHz [200 kHz]
[ ] : [FAST] switch set to “ON”
Advice:
It is possible to set the frequency change over one dial
rotation, separately for the CW mode, using the Menu
items “084 TUN DIALSTP” and “085 TUN CW FINE”.
FT DX 3000 Operating Manual
Page 37
Note
Page 38
FCC ID: K6620461X50 / IC: 511B-20461X50
FT DX 3000 Operating Manual
Convenience Features
FCC ID: K6620461X50 / IC: 511B-20461X50
Band Stack Operation
The FT DX 3000 utilizes a triple band-stack VFO selection technique, that permits you to store up to three favorite frequencies and modes onto each band’s VFO register. For example, you may store one frequency each on 14 MHz CW,
RTTY, and USB, then recall these VFOs by successive, momentary presses of the [14] MHz band button. Each Amateur
band key may similarly have up to three frequency/mode settings applied. Both the VFO-A and VFO-B systems have
their own, independent, band stacks.
A typical setup, for the 14 MHz band, might be arranged like this:
1. Program 14.025 MHz, CW Mode, then press the [14]
MHz band button;
2. Program 14.080 MHz, RTTY Mode, then press the
[14] MHz band button;
3. Program 14.195 MHz, SSB Mode, then press the [14]
MHz band button.
[BAND] Button
With this configuration, successive momentary presses
of the [14] MHz band button will allow you to step sequentially through these three VFOs.
C.S (Custom Switch)
The front panel [C.S] button may be programmed to directly access an often-used Menu Mode selection.
C.S Setup
1. Press and hold in the [MENU] button for one second
to engage the Menu mode; the Menu list will appear
on the display.
2. Rotate the [CLAR/VFO-B] knob or p/q button
to select the Menu item you want to access with the
front panel [C.S] button.
3. Press the [C.S] button to lock in your selection.
4. Press the [SELECT] button, then press the [MENU]
button to save the new configuration and exit to normal operation.
Menu Selection Recall via [C.S] button
[MENU] Button [SELECT] Button
[C.S] Button
[CLAR/VFO-B] Knob
Press the [C.S] button.
The programmed Menu item will appear on the display. You may now rotate the [CLAR/VFO-B] knob to
change the setting of this menu item. Press and hold the
[MENU] button for one second, when you are done, to
save the new configuration and exit to normal operation.
FT DX 3000 Operating Manual
Page 39

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Create Date                     : 2012:08:02 15:47:09+09:00
Metadata Date                   : 2012:08:10 18:56:28+09:00
Modify Date                     : 2012:08:10 18:56:28+09:00
Creator Tool                    : Adobe InDesign CS4_J (6.0.6)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 7267 bytes, use -b option to extract)
Instance ID                     : uuid:6d4f032f-f82f-437f-8cc6-2543eab6bfd0
Document ID                     : xmp.did:41D2C13194CCE1118508D8CD451513DA
Original Document ID            : xmp.did:3DD2C13194CCE1118508D8CD451513DA
Rendition Class                 : proof:pdf
History Action                  : created, saved, saved, saved, saved
History Instance ID             : xmp.iid:3DD2C13194CCE1118508D8CD451513DA, xmp.iid:3ED2C13194CCE1118508D8CD451513DA, xmp.iid:3FD2C13194CCE1118508D8CD451513DA, xmp.iid:40D2C13194CCE1118508D8CD451513DA, xmp.iid:41D2C13194CCE1118508D8CD451513DA
History When                    : 2012:07:13 11:41:05+09:00, 2012:07:13 11:41:43+09:00, 2012:07:13 11:41:43+09:00, 2012:07:13 11:43:49+09:00, 2012:07:13 11:43:49+09:00
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0
History Changed                 : /, /metadata, /metadata, /;/metadata
Derived From Instance ID        : xmp.iid:40D2C13194CCE1118508D8CD451513DA
Derived From Document ID        : xmp.did:3DD2C13194CCE1118508D8CD451513DA
Derived From Original Document ID: xmp.did:3DD2C13194CCE1118508D8CD451513DA
Derived From Rendition Class    : default
Manifest Link Form              : ReferenceStream
Manifest Placed X Resolution    : 350.00
Manifest Placed Y Resolution    : 350.00
Manifest Placed Resolution Unit : Inches
Manifest Reference Instance ID  : uuid:113652457FB4E111BA4BDFA2B77F5021
Manifest Reference Document ID  : uuid:0E3652457FB4E111BA4BDFA2B77F5021
Doc Change Count                : 6
Format                          : application/pdf
Title                           : FTDX3000_Operating_Manual
Creator                         : YAESU MUSEN CO., LTD.
Producer                        : Adobe PDF Library 9.0
Trapped                         : False
Page Count                      : 6
Author                          : YAESU MUSEN CO., LTD.
EXIF Metadata provided by EXIF.tools
FCC ID Filing: K6620461X50

Navigation menu