Yaesu Musen 20461X50 Scanning Receiver User Manual FTDX3000 Operating Manual

Yaesu Musen Co., Ltd. Scanning Receiver FTDX3000 Operating Manual

Users Manual 6

Download: Yaesu Musen 20461X50 Scanning Receiver User Manual FTDX3000 Operating Manual
Mirror Download [FCC.gov]Yaesu Musen 20461X50 Scanning Receiver User Manual FTDX3000 Operating Manual
Document ID1770291
Application IDCuUODe+YEoS/EzTMH+3/8g==
Document DescriptionUsers Manual 6
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize177.05kB (2213106 bits)
Date Submitted2012-08-20 00:00:00
Date Available2013-02-16 00:00:00
Creation Date2012-08-02 15:47:09
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2012-08-10 19:00:09
Document TitleFTDX3000_Operating_Manual
Document CreatorAdobe InDesign CS4_J (6.0.6)
Document Author: YAESU MUSEN CO., LTD.

Interference Rejection
FCC ID: K6620461X50 / IC: 511B-20461X50
µ-Tune
Filter (Requires the optional RF µTuning Kit)
Advice:
 The µ-Tune filters are the most advanced, selective RF preselector filters ever incorporated into an Amateur Radio
transceiver. The RF selectivity provided by µ-Tune can be of tremendous value in ensuring quiet, intermod-free
reception even in the most crowded bands on a contest weekend. The µ-Tune filters provide RF selectivity on the
order of a few dozen kHz at -6 dB, at the expense of a few dB of system gain on bands where noise figure is seldom
an issue. You will notice that the S-meter deflection, when µ-Tune is engaged, is slightly less than when it is out of
the circuit; this is normal. If your antenna system gain is so low that you cannot hear the band noise when µ-Tune is
engaged (highly unlikely), just switch it out, to eliminate the slight insertion loss.
 As you tune around on an amateur band with µ-Tune engaged, the microprocessor automatically commands the
stepper motor driving the toroid core stack to center the filter on your current operating frequency. You may, however, use the [SELECT(µ-TUNE)] knob to skew the filter response to one side or the other from your operating frequency, to deal with heavy interference on one side. To re-center the µ-Tune filter on your operating frequency, and
eliminate any offset, press the [CLEAR] button.
Changing the Tuning Offset Indicator
1. Press and hold in the [MENU ] button for one
second to engage the Menu mode.
2. Rotate the [CLAR/VFO-B] knob or p/q button
to select Menu item “011 DISPLAY BAR DISPLAY SELECT”.
3. Rotate the [CLAR/VFO-B] knob or p/q button to select “uTUNE (µ-Tune)” (replacing the
default “CW TUNE (CW TUNING)” selection).
4. Press the [ SELECT ] button, then press the
[MENU] button to lock in the new setting and
exit to normal operation.
[MENU] Button
[CLAR/VFO-B] Knob
Advice

If you want to use an external bandpass filter or preamplifier, you may connect it between the µ TO and µ FROM jacks
on the rear panel.
1. Connect the external equipment between the µ TO
and µ FROM jacks on the rear panel.
2. Press the [MHz/µT] button, then press the [CLAR/
VFO-B] knob. The receive signal will pass through
the external equipment. In this case, the “
” and
“
” icons will be shown in the FLT column of
the VFD display Block Diagram.
3. Press the [MHz/µT] button again, the receive signal
will bypass the external equipment and be applied
directly to the transceiver front-end circuit.
Advice:
Alternate presses of the [ MHz/µT ] button, will
switch the receive signal between the external equipment or the direct front-end receive circuit.
[MHz/µT] Button
[SELECT] Knob
Important Notice!
When [ µ-TUNE ] is enabled, the FT DX 3000
cannot receive a signal without an external device
of jumper cable between the µ TO and µ FROM
jacks.
FT DX 3000 Operating Manual
Page 45
Interference Rejection
FCC ID: K6620461X50 / IC: 511B-20461X50
IPO (Intercept Point Optimization)
The IPO feature allows the operator to optimize the characteristics of the receiver front end, depending on the current
noise level and the strength of incoming signals.
Press the [IPO] button several times to set the desired
characteristic of the receiver front end, according to the
chart below.
[IPO] Button
AMP1: Amplifies the incoming signals, using a low
distortion RF preamplifier (gain: approx. 10
dB).
AMP2: Amplifies the incoming signals, using a
2-stage low-distortion RF preamplifier (total
gain: approx. 17 dB).
IPO: Bypasses the RF preamplifier, yielding direct
feed to the first mixer.
The selected receiver RF preamplifier will be indicated
in the IPO column of the Block Diagram Display on the
display.
Advice:
 The IPO selection will be memorized independently
on each VFO stack of VFO-A and VFO-B.
 On the 10 MHz and lower bands, it generally is not
necessary to use any preamplifier at all; selecting the
“IPO ON” position as described above will increase
the strong-signal-handling capability of the receiver,
and generally will result in more pleasant reception
due to reduced noise. If you can hear band noise with
the preamplifiers disengaged, then a preamplifier is
generally not needed.
Note:
The IPO feature is always on “IPO ON” (No RF preamplifier) between 30 kHz and 1.7 MHz.
Page 46
FT DX 3000 Operating Manual
Interference Rejection
FCC ID: K6620461X50 / IC: 511B-20461X50
R.FLT (Roofing Filters)
Narrow-band Roofing Filters of 15 kHz, 6 kHz, and 3 kHz bandwidths are provided in the first IF, right after the first
mixer. These filters provide protection for the 2nd mixer, DSP, and other circuitry that follow and can dramatically improve reception on a very crowded band (during a contest, etc.). Typically, the AUTO selection mode is satisfactory for
most operating situations, but in an extremely crowded phone band you may wish to select, for example, the 3 kHz roofing filter for SSB operation.
Press the [R.FLT] button to toggle the Roofing Filter
selection.
[R.FLT] Button
AUTO  15 kHz  6 kHz  3 kHz  AUTO .....
Advice:
 As you repeatedly press the [R.FLT] button, you will
observe changes in the notation in the R.FLT column
of the Block Diagram Display on the display, denoting the Roofing Filter currently in use.
 Typically, this selection will be set to “AUTO.”
 The Roofing Filter selection will be memorized independently on each VFO stack of VFO-A and VFO-B.
Quick Point:
The “AUTO” selection of the Roofing Filter is based on
the operating mode. However, you may override the automatic selection, if band conditions warrant a different
(usually, a tighter) selection.
FT DX 3000 Operating Manual
Terminology:
A “Roofing Filter,” as its name implies, places a “Roof”
over the receiver’s IF system bandwidth. This “Roof”
protects the circuitry downstream from the first mixer
from interference, just as a roof on a house protects the
contents from rain and snow.
Page 47
Interference Rejection
FCC ID: K6620461X50 / IC: 511B-20461X50
IF Noise Blanker (NB) Operation
The FT DX 3000 includes an effective IF Noise Blanker, which can significantly reduce noise caused by automotive ignition systems.
1. Press the [NB] button briefly to reduce short duration pulse noise such as from switching transients,
automobile ignitions and power lines. The “NB ON”
will appear in the display to confirm that the NarrowNB is operating.
2. Press the [NB] button again to reduce longer-duration man-made pulse noise. The “NBW ON” will
appear in the display to confirm that the Wide-NB is
operating.
2. If desired, you may adjust the Noise Blanker level
via Menu item “033 GENERAL NB LEVEL” to the
point where the offending noise is best reduced or
eliminated. See box below for details.
3. To end Noise Blanker operation, press the [NB] button once more. The “NB OFF” will appear in the
display, confirming that the Noise Blanker is no longer in operation.
[NB] Button
Advice:
The Noise Blanker operation will be memorized independently on each VFO stack of VFO-A and VFO-B.
However, the Noise Blanker level is in common.
Adjusting the Noise Blanker Level
1. Press and hold in the [MENU ] button for one
second to engage the Menu mode.
2. Rotate the [CLAR/VFO-B] knob or p/q button
to select Menu item “033 GENERAL NB LEVEL”.
3. Rotate the [CLAR/VFO-B] knob or p/q button to the point where the offending noise is best
reduced or eliminated.
4. Press the [ SELECT ] button, then press the
[MENU] button to lock in the new setting and
exit to normal operation.
Page 48
[MENU] Button
[CLAR/VFO-B] Knob
FT DX 3000 Operating Manual

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Create Date                     : 2012:08:02 15:47:09+09:00
Metadata Date                   : 2012:08:10 19:00:09+09:00
Modify Date                     : 2012:08:10 19:00:09+09:00
Creator Tool                    : Adobe InDesign CS4_J (6.0.6)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 7267 bytes, use -b option to extract)
Instance ID                     : uuid:6578e61e-c2ff-47d3-aa91-8ac9ce543158
Document ID                     : xmp.did:41D2C13194CCE1118508D8CD451513DA
Original Document ID            : xmp.did:3DD2C13194CCE1118508D8CD451513DA
Rendition Class                 : proof:pdf
History Action                  : created, saved, saved, saved, saved
History Instance ID             : xmp.iid:3DD2C13194CCE1118508D8CD451513DA, xmp.iid:3ED2C13194CCE1118508D8CD451513DA, xmp.iid:3FD2C13194CCE1118508D8CD451513DA, xmp.iid:40D2C13194CCE1118508D8CD451513DA, xmp.iid:41D2C13194CCE1118508D8CD451513DA
History When                    : 2012:07:13 11:41:05+09:00, 2012:07:13 11:41:43+09:00, 2012:07:13 11:41:43+09:00, 2012:07:13 11:43:49+09:00, 2012:07:13 11:43:49+09:00
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0
History Changed                 : /, /metadata, /metadata, /;/metadata
Derived From Instance ID        : xmp.iid:40D2C13194CCE1118508D8CD451513DA
Derived From Document ID        : xmp.did:3DD2C13194CCE1118508D8CD451513DA
Derived From Original Document ID: xmp.did:3DD2C13194CCE1118508D8CD451513DA
Derived From Rendition Class    : default
Manifest Link Form              : ReferenceStream
Manifest Placed X Resolution    : 350.00
Manifest Placed Y Resolution    : 350.00
Manifest Placed Resolution Unit : Inches
Manifest Reference Instance ID  : uuid:113652457FB4E111BA4BDFA2B77F5021
Manifest Reference Document ID  : uuid:0E3652457FB4E111BA4BDFA2B77F5021
Doc Change Count                : 6
Format                          : application/pdf
Title                           : FTDX3000_Operating_Manual
Creator                         : YAESU MUSEN CO., LTD.
Producer                        : Adobe PDF Library 9.0
Trapped                         : False
Page Count                      : 4
Author                          : YAESU MUSEN CO., LTD.
EXIF Metadata provided by EXIF.tools
FCC ID Filing: K6620461X50

Navigation menu